CISCO-CDSTV-INGESTMGR-MIB
The CISCO-CDSTV-INGESTMGR-MIB provides management objects for the Cisco Content Delivery System for TV (CDS-TV) Ingest Manager to configure and monitor the acquisition, metadata collection, and expiration of video content across Vault, Caching Node, and Streamer roles. This module enables administrators to control content ingestion workflows, including the provisioning of content objects and the coordination of data transfer via protocols such as CCP, FTP, and RTSP within the CDS-TV architecture.
Imported Objects
Objects
40 total| Object Name |
|---|
ciscoCdstvIngestmgrMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.739 |
ciscoCdstvIngestMgrMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.739.0 |
ciscoCdstvIngestMgrMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.739.1 |
cdstvIngestMgrGeneralSettings OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.739.1.1 |
cdstvIngestMgrHostAddressTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.739.1.1.1 |
cdstvIngestMgrHostAddressrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.739.1.1.2 |
cdstvIngestMgrPortrw InetPortNumber .1.3.6.1.4.1.9.9.739.1.1.3 |
cdstvIngestMgrFsiCallbackPortrw InetPortNumber .1.3.6.1.4.1.9.9.739.1.1.4 |
cdstvIngestMgrAdditionalPackageWindowrw Unsigned32 UNITS "days" .1.3.6.1.4.1.9.9.739.1.1.5 |
cdstvIngestMgrFtpTimeoutrw TimeIntervalSec (CISCO-TC) .1.3.6.1.4.1.9.9.739.1.1.6 |
cdstvIngestMgrUseAssetIdEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.739.1.1.7 |
cdstvIngestMgrManageCorbaServicesrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.739.1.1.8 |
cdstvIngestMgrRequireNotifyServicerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.739.1.1.9 |
cdstvIngestMgrDebugLevelrw Enumeration .1.3.6.1.4.1.9.9.739.1.1.10 |
cdstvIngestMgrMetaDataPublishrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.739.1.1.11 |
cdstvIngestMgrMetaPublishUrlrw CiscoURLString (CISCO-TC) .1.3.6.1.4.1.9.9.739.1.1.12 |
cdstvIngestMgrMetaPublishBackupUrlrw CiscoURLStringOrEmpty (CISCO-TC) .1.3.6.1.4.1.9.9.739.1.1.13 |
cdstvIngestMgrIngestSettings OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.739.1.2 |
cdstvIngestMgrIngestInterfacerw Bits .1.3.6.1.4.1.9.9.739.1.2.1 |
cdstvIngestMgrCiscoSoapUrlrw CiscoURLStringOrEmpty (CISCO-TC) .1.3.6.1.4.1.9.9.739.1.2.2 |
cdstvIngestMgrProdisSoapUrlrw CiscoURLStringOrEmpty (CISCO-TC) .1.3.6.1.4.1.9.9.739.1.2.3 |
cdstvIngestMgrBackOfficeSettings OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.739.1.3 |
cdstvIngestMgrBackOfficeMaxRetriesrw Unsigned32 .1.3.6.1.4.1.9.9.739.1.3.1 |
cdstvIngestMgrBackOfficeRetryIntervalrw TimeIntervalMin (CISCO-TC) .1.3.6.1.4.1.9.9.739.1.3.2 |
cdstvIngestMgrBackOfficeTimeoutrw TimeIntervalSec (CISCO-TC) .1.3.6.1.4.1.9.9.739.1.3.3 |
cdstvIngestMgrBackOfficeTable SEQUENCE OF CdstvIngestMgrBackOfficeEntry .1.3.6.1.4.1.9.9.739.1.3.4 |
cdstvIngestMgrBackOfficeEntry CdstvIngestMgrBackOfficeEntry .1.3.6.1.4.1.9.9.739.1.3.4.1 |
cdstvIngestMgrBackOfficeIndex Unsigned32 .1.3.6.1.4.1.9.9.739.1.3.4.1.1 |
cdstvIngestMgrBackOfficeTyperw Enumeration .1.3.6.1.4.1.9.9.739.1.3.4.1.2 |
cdstvIngestMgrBackOfficeUrlrw CiscoURLStringOrEmpty (CISCO-TC) .1.3.6.1.4.1.9.9.739.1.3.4.1.3 |
cdstvIngestMgrContentStoreSettings OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.739.1.4 |
cdstvIngestMgrContentStorerw Enumeration .1.3.6.1.4.1.9.9.739.1.4.1 |
cdstvIngestMgrContentStoreUrlrw CiscoURLStringOrEmpty (CISCO-TC) .1.3.6.1.4.1.9.9.739.1.4.2 |
cdstvIngestMgrEncryptionSettings OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.739.1.5 |
cdstvIngestMgrEncryptionTyperw Enumeration .1.3.6.1.4.1.9.9.739.1.5.1 |
cdstvIngestMgrEncryptionTargetUrlrw CiscoURLStringOrEmpty (CISCO-TC) .1.3.6.1.4.1.9.9.739.1.5.2 |
cdstvIngestMgrEncryptionRetrievalUrlrw CiscoURLStringOrEmpty (CISCO-TC) .1.3.6.1.4.1.9.9.739.1.5.3 |
ciscoCdstvIngestMgrMIBConform OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.739.2 |
ciscoCdstvIngestMgrMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.739.2.1 |
ciscoCdstvIngestMgrMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.739.2.2 |
CISCO-CDSTV-INGESTMGR-MIB Technical Reference Overview
The CISCO-CDSTV-INGESTMGR-MIB SNMP MIB module published by Cisco defines 40 managed OID objects, including 27 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.739. Key tabular structures include cdstvIngestMgrBackOfficeTable.
Key OID Definitions in CISCO-CDSTV-INGESTMGR-MIB
.1.3.6.1.4.1.9.9.739This MIB module defines ingest manager configuration objects that faciliate the management of the Cisco Content Delivery System for TV (CDS-TV) product family. CDS-TV is a suite of products and software applications providing ingest, storage, caching, streaming, playout and on-demand delivery of video to television or set-top-box clients. Abbreviations: CCP Cache Control Protocol CDS Content Delivery System CORBA Common Object Request Broker Architecture ISA Interactive Services Architecture ISV Integrated Streamer-Vault FSI File Service Interface FTP File Transfer Protocol MPEG Motion Picture Experts Group MSA Managed Services Architecture RTSP Real-Time Streaming Protocol STB Set-Top Box Common terms: Catcher: Device responsible for receiving content (typically via satellite dishes and antennae) from content providers or from a Headend-In-The-Sky. Content Ingest: Acquisition of content from a source such as a catcher or an FTP server for storing it locally and making it available to streamers as needed. Ingest Manager: CDS module that takes care of provisioned content objects by collecting metadata, sending messages to the appropriate subsystem to ingest the content, and sending messages to expire the content when the expiration period has passed. Device Roles: Vault: Content delivery application responsible for ingesting and storing video content and making it available to streamers and/or caching nodes. Caching Nodes: Content delivery application responsible for caching content from vault (using CCP) and then streaming content out to streamers over HTTP or CCP. Streamer: Content delivery application responsible for streaming video out to STB's. ISV: Content delivery application capable of acting as both a vault and as a streamer in a single device.
.1.3.6.1.4.1.9.9.739.1.3.4A table containing the back-office type and URL settings.
.1.3.6.1.4.1.9.9.739.1.1.1This object specifies the type of the IP address (specified by cdstvIngestMgrHostAddress) of the Ingest Manager.
.1.3.6.1.4.1.9.9.739.1.1.2This object specifies the IP address of the Ingest Manager. The type of this address is specified by cdstvIngestMgrHostAddressType.
.1.3.6.1.4.1.9.9.739.1.1.3This object specifies the port number to use for listening for inbound connections.
.1.3.6.1.4.1.9.9.739.1.1.4This object specifies the port number to use for File Services Interface (FSI) callbacks.
.1.3.6.1.4.1.9.9.739.1.1.5This object specifies the additional amount of time to wait once the package expiration window has ended before destroying the stored content package. Typically, when the package expiration window ends, the ingested content package is destroyed from the device. The additional package window adds a grace period to the expiration window.
.1.3.6.1.4.1.9.9.739.1.1.6This object specifies the maximum period the Ingest Manager waits before timing out an FTP session and terminating the process.
.1.3.6.1.4.1.9.9.739.1.1.7This object specifies whether to use the Asset ID (a unique ID assigned to each content ingested into the CDS) for the content name. 'true' indicates that Asset ID is used for the content name. 'false' indicates Asset ID is not used for the content name.
.1.3.6.1.4.1.9.9.739.1.1.8This object specifies whether the CDS manages the CORBA services. 'true' indicates that CDS manages CORBA services. 'false' indicates that CDS does not manage CORBA services.
.1.3.6.1.4.1.9.9.739.1.1.9This object specifies whether the CDS requires the use of ISA Notify Service. 'true' indicates that CDS requires the use of ISA Notify Service. 'false' indicates that CDS does not require the use of ISA Notify Service.
.1.3.6.1.4.1.9.9.739.1.1.10This object specifies the amount of debugging information logged. errors(1) - Only error messages are logged. all(2) - Errors, warnings and success message are all logged. off(3) - Debugging is disabled.
.1.3.6.1.4.1.9.9.739.1.1.11This object specifies whether content metadata is published or not. 'true' indicates that content metadata is published. 'false' indicates that content metadata is not published.
.1.3.6.1.4.1.9.9.739.1.1.12This object specifies the URL where the metadata is published, typically the back-office.
.1.3.6.1.4.1.9.9.739.1.1.13This object specifies the URL of the backup server where the metadata is published. This string is empty if a backup server URL is not configured.
.1.3.6.1.4.1.9.9.739.1.2.1This object specifies all ingest interfaces (methods) available, i.e. ISA, Cisco SOAP, Prodis SOAP or any combination of the three. isa(0) - ISA. ciscoSoap(1) - Cisco SOAP prodisSoap(2) - Prodis SOAP.
.1.3.6.1.4.1.9.9.739.1.2.2This object specifies the URL (IP address, port, and directory) on the Vault used to receive content using the Cisco SOAP (Simple Object Access Protocol). An example of the Cisco SOAP URL is http://10.22.216.251:8793/CiscoAIM. This string is empty if Cisco SOAP is not used.
.1.3.6.1.4.1.9.9.739.1.2.3This object specifies the URL (IP address, port, and directory) on the Vault used to receive content using the Prodis SOAP(Simple Object Access Protocol). An example of the Prodis SOAP URL is http://10.22.216.251:8793/ProdisAIM. This string is empty if Prodis SOAP is not used.
.1.3.6.1.4.1.9.9.739.1.3.1This object specifies the maximum number of times to retry a failed communication with the back-office.
.1.3.6.1.4.1.9.9.739.1.3.2This object specifies the amount of time to wait before retrying a failed communication with the back-office.
.1.3.6.1.4.1.9.9.739.1.3.3This object specifies the amount of time to wait for the back-office to respond to a communication attempt.
.1.3.6.1.4.1.9.9.739.1.4.1This object specifies the type of content store used. none(1) - Content store is disabled. isa(2) - Use ISA content store. fsi(3) - Use FSI content store. ngod(4) - Use Next-Generation On-Demand (NGOD) content store. openStream(5) - Use OpenStream content store.
.1.3.6.1.4.1.9.9.739.1.4.2This object specifies the URL where the content store is located. This string is empty if content store is disabled.
.1.3.6.1.4.1.9.9.739.1.5.1This object specifies the type of encryption used. none(1) - Encryption is disabled. verimatrix(2) - Use Verimatrix encryption. widevine(3) - Use Widevine encryption.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.