CISCO-CDSTV-CS-STATS-MIB
The CISCO-CDSTV-CS-STATS-MIB monitors caching and streaming performance metrics for Cisco Content Delivery System (CDS-TV) appliances, specifically tracking ingestion, vault storage, and streamer-to-Set-Top Box delivery statistics within a Video on Demand (VOD) and network DVR architecture.
Imported Objects
Objects
46 total| Object Name |
|---|
ciscoCdstvCsStatsMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.743 |
ciscoCdstvStatsMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.743.0 |
ciscoCdstvStatsMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.743.1 |
ciscoCdstvCacheStats OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.743.1.1 |
cdstvCacheCapacityro Unsigned32 .1.3.6.1.4.1.9.9.743.1.1.1 |
cdstvCacheLevelro Gauge32 UNITS "kilobytes" .1.3.6.1.4.1.9.9.743.1.1.2 |
cdstvFillReceiveStreamsro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.1.3 |
cdstvFillStreamCommittedBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.1.4 |
cdstvFillStreamActualBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.1.5 |
cdstvDiskReadStreamsro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.1.6 |
cdstvDiskReadBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.1.7 |
cdstvCCPInfromVaultStreamsro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.1.8 |
cdstvCCPInFromVaultStreamBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.1.9 |
cdstvCCPInFromCacheStreamsro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.1.10 |
cdstvCCPInFromCacheStreamBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.1.11 |
cdstvCCPInFromStreamerStreamCountro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.1.12 |
cdstvCCPInFromStreamerStreamBWro Unsigned32 .1.3.6.1.4.1.9.9.743.1.1.13 |
cdstvHTTPInStreamsro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.1.14 |
cdstvHTTPInStreamBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.1.15 |
cdstvActiveIngestStreamsro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.1.16 |
cdstvActiveIngestStreamBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.1.17 |
ciscoCdstvStreamStats OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.743.1.2 |
cdstvActiveStreamsro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.2.1 |
cdstvActiveStreamBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.2.2 |
cdstvUniqueStreamsro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.2.3 |
cdstvUniqueStreamBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.2.4 |
cdstvCCPOutStreamsro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.2.5 |
cdstvCCPOutStreamBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.2.6 |
cdstvHTTPOutStreamsro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.2.7 |
cdstvHTTPOutStreamBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.2.8 |
cdstvSessionSetupSuccessro Counter32 .1.3.6.1.4.1.9.9.743.1.2.9 |
cdstvSessionSetupFailuresro Counter32 .1.3.6.1.4.1.9.9.743.1.2.10 |
cdstvSecondsSinceReferencero TimeIntervalSec (CISCO-TC) .1.3.6.1.4.1.9.9.743.1.2.11 |
cdstvStreamControlMessageQueueMaxro Unsigned32 UNITS "elements" .1.3.6.1.4.1.9.9.743.1.2.12 |
cdstvStreamControlMessageQueueSizero Unsigned32 UNITS "elements" .1.3.6.1.4.1.9.9.743.1.2.13 |
cdstvSkippedPlaylistElementsro Unsigned32 UNITS "elements" .1.3.6.1.4.1.9.9.743.1.2.14 |
cdstvStatsByContentTypeTable SEQUENCE OF CdstvStatsByContentTypeEntry .1.3.6.1.4.1.9.9.743.1.2.15 |
cdstvStatsByContentTypeEntry CdstvStatsByContentTypeEntry .1.3.6.1.4.1.9.9.743.1.2.15.1 |
cdstvContentType Enumeration .1.3.6.1.4.1.9.9.743.1.2.15.1.1 |
cdstvActiveEgressCountro Gauge32 UNITS "stream count" .1.3.6.1.4.1.9.9.743.1.2.15.1.2 |
cdstvActiveEgressBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.2.15.1.3 |
cdstvActiveIngressCountro Gauge32 UNITS "fill count" .1.3.6.1.4.1.9.9.743.1.2.15.1.4 |
cdstvActiveIngressBWro Gauge32 UNITS "kilobits" .1.3.6.1.4.1.9.9.743.1.2.15.1.5 |
ciscoCdstvStatsMIBConform OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.743.2 |
ciscoCdstvStatsMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.743.2.1 |
ciscoCdstvStatsMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.743.2.2 |
CISCO-CDSTV-CS-STATS-MIB Technical Reference Overview
The CISCO-CDSTV-CS-STATS-MIB SNMP MIB module published by Cisco defines 46 managed OID objects, including 36 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.743. Key tabular structures include cdstvStatsByContentTypeTable.
Key OID Definitions in CISCO-CDSTV-CS-STATS-MIB
.1.3.6.1.4.1.9.9.743This MIB module defines objects describing the caching and streaming statistics objects that facilitate the management of the Cisco CDS-TV product family. CDS-TV is a suite of products and software applications providing ingest, storage, caching, streaming, playout and on-demand delivery of video to television or STB clients. ACRONYMS CCP Content Control Protocol CDN Content Distribution Network CDS Content Delivery System ISA Interactive Services Architecture ISV Integrated Streamer-Vault FSI File Service Interface FTP File Transfer Protocol HTTP Hyper-Text Transfer Protocol MPEG Motion Picture Experts Group MSA Managed Services Architecture NDVR Network Digital Video Recorder RTSP Real-Time Streaming Protocol STB Set-Top Box VOD Video On Demand GLOSSARY Catcher: Device responsible for receiving content (typically via satellite dishes and antennae) from content providers or from a Headend-In-The-Sky. Content Ingest: Acquisition of content (from a source such as a catcher or an FTP server) for the purpose of storing it locally in a vault and making it available to streamers and caching nodes as needed. Vault: Content delivery application responsible for ingesting video content, storing it, and making it available to streamers. Caching Node: Content delivery application responsible for caching content from a vault and streaming it to other caching nodes or streamers. Streamer: Content delivery application responsible for streaming video to STB's.
.1.3.6.1.4.1.9.9.743.1.2.15This table lists the fill (ingress) and stream (egress) counts as well as the bandwidth used by the ingress fills and egress streams on this streamer, differentiated by the content type.
.1.3.6.1.4.1.9.9.743.1.1.1This object indicates the total cache capacity of this streamer, caching node or ISV.
.1.3.6.1.4.1.9.9.743.1.1.2This object indicates the used cache level for this streamer, caching node or ISV.
.1.3.6.1.4.1.9.9.743.1.1.3This object indicates the total number of cache fills this streamer, caching node or ISV gets from other devices. For a streamer or ISV, the source devices can be vaults, caching nodes or neighboring streamers. For caching nodes, the source can be vaults or neighboring caching nodes. For streamers, this metric includes both CCP and HTTP streams.
.1.3.6.1.4.1.9.9.743.1.1.4This object indicates the committed bandwidth for cache fills this streamer, caching node or ISV gets from other devices. For a streamer or ISV , the other devices can be vaults, caching nodes or neighboring streamers. For caching nodes, the other devices can be vaults or neighboring caching nodes. For streamers, this metric includes both CCP and HTTP streams.
.1.3.6.1.4.1.9.9.743.1.1.5This object indicates the actual bandwidth of cache fills this streamer, caching node or ISV gets from other devices. For a streamer or ISV, the other devices can be vaults, caching nodes or neighboring streamers. For caching nodes, the other devices can be vaults or neighboring caching nodes. For streamers, this metric includes both CCP and HTTP streams.
.1.3.6.1.4.1.9.9.743.1.1.6This object indicates the disk-read stream count for this streamer, caching node or ISV, i.e. the number of streams served from this device's disks.
.1.3.6.1.4.1.9.9.743.1.1.7this object indicates the disk-read bandwidth for this streamer, caching node or ISV, i.e. the bandwidth of the streams read from this device's disk.
.1.3.6.1.4.1.9.9.743.1.1.8This object indicates the number of CCP streams from a vault filling this device.
.1.3.6.1.4.1.9.9.743.1.1.9This object indicates the bandwidth of CCP streams from a vault filling this device.
.1.3.6.1.4.1.9.9.743.1.1.10This object indicates the number of CCP streams from a caching node filling this caching node or streamer.
.1.3.6.1.4.1.9.9.743.1.1.11This object indicates the bandwidth of CCP streams from a caching node filling this device.
.1.3.6.1.4.1.9.9.743.1.1.12This object indicates the number of CCP streams from another streamer filling this streamer.
.1.3.6.1.4.1.9.9.743.1.1.13This object indicates the bandwidth of CCP streams from other streamers filling this streamer.
.1.3.6.1.4.1.9.9.743.1.2.1This object specifies the number of active streams from this device. For a streamer, this includes CCP streams going out to other streamers. For caching nodes and vaults, this includes CCP streams going out to streamers or caching nodes. For vaults, this includes mirroring traffic as well.
.1.3.6.1.4.1.9.9.743.1.2.2This object indicates the bandwidth of active streams from this device. For a streamer, this includes CCP streams going out to other streamers. For caching nodes and vaults, this includes CCP streams going out to streamers or caching nodes. For vaults, this includes mirroring traffic as well.
.1.3.6.1.4.1.9.9.743.1.2.3This object indicates the number of unique streams going out from this device.
.1.3.6.1.4.1.9.9.743.1.2.4This object indicates the bandwidth of unique streams going out from this device.
.1.3.6.1.4.1.9.9.743.1.2.5This object indicates the number of CCP streams going out from this device. For streamers, the destination is another streamer. For caching nodes, the destination is a streamer or another caching node. For vaults, the destination can be a streamer, caching node or vault.
.1.3.6.1.4.1.9.9.743.1.2.6This object indicates the bandwidth of CCP streams going out from this device. For streamers, the destination is another streamer. For caching nodes, the destination is a streamer or another caching node. For vaults, the destination can be a streamer, caching node or vault.
.1.3.6.1.4.1.9.9.743.1.2.7This object indicates the number of HTTP streams going out from this caching node to streamers in a CDN setup.
.1.3.6.1.4.1.9.9.743.1.2.8This object indicates the bandwidth of HTTP streams going out from this caching node to streamers in a CDN setup.
.1.3.6.1.4.1.9.9.743.1.2.9This object indicates the number of successfully setup sessions since the counter was reset (the reference). The seconds elapsed since the reference is indicated by cdstvSecondsSinceReference.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.