Home/Catalog/CISCO-CDSTV-BWMGR-MIB

CISCO-CDSTV-BWMGR-MIB

AI MIB Summary

The CISCO-CDSTV-BWMGR-MIB enables monitoring and configuration of bandwidth allocation, active stream counts, and VOD network resource utilization on Cisco Content Delivery System for TV (CDS-TV) master streamers. This module facilitates the management of video ingest, caching, and streaming workflows by tracking session states and resource distribution across the CDS-TV architecture.

This MIB module defines Bandwidth Manager configuration objects that facilitate the management of the Cisco Content Delivery System for TV (CDS-TV) product family. CDS-TV is a suite of products and software applications providing ingest, storage, caching, streaming, playout and on-demand delivery of video to television or set-top-box clients. The Bandwidth Manager runs on the master streamer and keeps track of allocated streams and VOD network resources. Abbreviations: CCP Cache Control Protocol CDS Content Delivery System CORBA Common Object Request Broker Architecture ISA Interactive Services Architecture ISV Integrated Streamer-Vault FSI File Service Interface FTP File Transfer Protocol MPEG Motion Picture Experts Group MSA Managed Services Architecture RTSP Real-Time Streaming Protocol SOAP Simple Object Access Protocol STB Set-Top Box VOD Video On-Demand Common terms: Catcher: Device responsible for receiving content (typically via satellite dishes and antennae) from content providers or from a Headend-In-The-Sky. Content Ingest: Acquisition of content from a source such as a catcher or an FTP server for storing it locally and making it available to streamers as needed. Device Roles: Vault: Content delivery application responsible for ingesting and storing video content and making it available to streamers and/or caching nodes. Caching Nodes: Content delivery application responsible for caching content from vault (using CCP) and then streaming content out to streamers over HTTP or CCP. Streamer: Content delivery application responsible for streaming video out to STB's. ISV: Content delivery application capable of acting as both a vault and as a streamer in a single device.
Main OID:
ciscoCdstvBwmgrMIB.1.3.6.1.4.1.9.9.749
13
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

13 total
Object Name
ciscoCdstvBwmgrMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.749
ciscoCdstvBWMgrMIBNotifs
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.749.0
ciscoCdstvBWMgrMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.749.1
cdstvBWMgrAddressTyperw
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.749.1.1
cdstvBWMgrAddressrw
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.9.9.749.1.2
cdstvBWMgrPortrw
InetPortNumber
.1.3.6.1.4.1.9.9.749.1.3
cdstvBWMgrDatabaseThreadPoolrw
Unsigned32
.1.3.6.1.4.1.9.9.749.1.4
cdstvBWMgrServerThreadPoolrw
Unsigned32
.1.3.6.1.4.1.9.9.749.1.5
cdstvBWMgrSyncThreadPoolrw
Unsigned32
.1.3.6.1.4.1.9.9.749.1.6
cdstvBWMgrSyncAlarmrw
TimeIntervalSec
.1.3.6.1.4.1.9.9.749.1.7
ciscoCdstvBWMgrMIBConform
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.749.2
ciscoCdstvBWMgrMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.749.2.1
ciscoCdstvBWMgrMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.749.2.2

CISCO-CDSTV-BWMGR-MIB Technical Reference Overview

The CISCO-CDSTV-BWMGR-MIB SNMP MIB module published by Cisco defines 13 managed OID objects, including 7 scalar/column metrics, 0 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.749.

Key OID Definitions in CISCO-CDSTV-BWMGR-MIB

ciscoCdstvBwmgrMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.749

This MIB module defines Bandwidth Manager configuration objects that facilitate the management of the Cisco Content Delivery System for TV (CDS-TV) product family. CDS-TV is a suite of products and software applications providing ingest, storage, caching, streaming, playout and on-demand delivery of video to television or set-top-box clients. The Bandwidth Manager runs on the master streamer and keeps track of allocated streams and VOD network resources. Abbreviations: CCP Cache Control Protocol CDS Content Delivery System CORBA Common Object Request Broker Architecture ISA Interactive Services Architecture ISV Integrated Streamer-Vault FSI File Service Interface FTP File Transfer Protocol MPEG Motion Picture Experts Group MSA Managed Services Architecture RTSP Real-Time Streaming Protocol SOAP Simple Object Access Protocol STB Set-Top Box VOD Video On-Demand Common terms: Catcher: Device responsible for receiving content (typically via satellite dishes and antennae) from content providers or from a Headend-In-The-Sky. Content Ingest: Acquisition of content from a source such as a catcher or an FTP server for storing it locally and making it available to streamers as needed. Device Roles: Vault: Content delivery application responsible for ingesting and storing video content and making it available to streamers and/or caching nodes. Caching Nodes: Content delivery application responsible for caching content from vault (using CCP) and then streaming content out to streamers over HTTP or CCP. Streamer: Content delivery application responsible for streaming video out to STB's. ISV: Content delivery application capable of acting as both a vault and as a streamer in a single device.

cdstvBWMgrAddressTypeInetAddressTyperead-write
.1.3.6.1.4.1.9.9.749.1.1

This object specifies the type of address used by the Bandwidth Manager. The address is specified by cdstvBWMgrAddress.

cdstvBWMgrAddressInetAddressread-write
.1.3.6.1.4.1.9.9.749.1.2

This object specifies the address used by the Bandwidth Manager. The type of the address is specified by cdstvBWMgrAddressType.

cdstvBWMgrPortInetPortNumberread-write
.1.3.6.1.4.1.9.9.749.1.3

This object specifies the port number to listen on for incoming connections from the RTSP server.

cdstvBWMgrDatabaseThreadPoolUnsigned32read-write
.1.3.6.1.4.1.9.9.749.1.4

This object specifies the maximum number of threads in the database connection pool.

cdstvBWMgrServerThreadPoolUnsigned32read-write
.1.3.6.1.4.1.9.9.749.1.5

This object specifies the maximum number of threads in the Bandwidth Manager server pool that are used to process RTSP requests for the duration of the connection.

cdstvBWMgrSyncThreadPoolUnsigned32read-write
.1.3.6.1.4.1.9.9.749.1.6

This object specifies the maximum number of threads available to synchronize sessions with the RTSP during a synchronization operation.

cdstvBWMgrSyncAlarmTimeIntervalSecread-write
.1.3.6.1.4.1.9.9.749.1.7

This object specifies how often the synchronization alarm is triggered. The alarm is generated if the synchronization between RTSP client and server (typically, streamer and back-office, but varies by CDS deployment environment) fails. Note that this does not generate an SNMP notification.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→