CISCO-CDL-MIB
The CISCO-CDL-MIB manages Converged Data Link (CDL) OAM&P functions on Cisco optical Ethernet interfaces by monitoring defect indications and configuring packet-by-packet multiplexing for elementary stream identification. It specifically tracks APS signaling states and multiplexing identifiers to facilitate automatic protection switching and bandwidth sharing without a SONET/SDH layer, excluding the separate management of the CDL message channel.
Imported Objects
Objects
45 total| Object Name |
|---|
ciscoCdlMIB MODULE-IDENTITY .1.3.6.1.4.1.9.10.88 |
coCdlMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.88.0 |
coCdlRxAggDefectIndChange NOTIFICATION-TYPE .1.3.6.1.4.1.9.10.88.0.1 |
coCdlFromCdlNetFlowDIChange NOTIFICATION-TYPE .1.3.6.1.4.1.9.10.88.0.2 |
coCdlMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.88.1 |
coCdlBaseGroup OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.88.1.1 |
coCdlIntfTable SEQUENCE OF CoCdlIntfEntry .1.3.6.1.4.1.9.10.88.1.1.1 |
coCdlIntfEntry CoCdlIntfEntry .1.3.6.1.4.1.9.10.88.1.1.1.1 |
coCdlAdminStatusrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.10.88.1.1.1.1.1 |
coCdlForceEndOfHoprw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.10.88.1.1.1.1.2 |
coCdlNodeBehaviorro CoCdlNodeBehavior .1.3.6.1.4.1.9.10.88.1.1.1.1.3 |
coCdlRxAggDefectIndCurrStatusro CoCdlAggDefectIndStatus .1.3.6.1.4.1.9.10.88.1.1.1.1.4 |
coCdlRxAggDefectIndLastChangero TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.9.10.88.1.1.1.1.5 |
coCdlTxAggDefectIndCurrStatusro CoCdlAggDefectIndStatus .1.3.6.1.4.1.9.10.88.1.1.1.1.6 |
coCdlTxAggDefectIndLastChangero TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.9.10.88.1.1.1.1.7 |
coCdlTransmitMaxFlowIdentifierrw CoCdlFlowIdentifier .1.3.6.1.4.1.9.10.88.1.1.1.1.8 |
coCdlReceiveMaxFlowIdentifierrw CoCdlFlowIdentifier .1.3.6.1.4.1.9.10.88.1.1.1.1.9 |
coCdlRxHeaderCRCErrorro Counter32 .1.3.6.1.4.1.9.10.88.1.1.1.1.10 |
coCdlRxHeaderCRCErrorOverflowro Counter32 .1.3.6.1.4.1.9.10.88.1.1.1.1.11 |
coCdlHCRxHeaderCRCErrorro Counter64 .1.3.6.1.4.1.9.10.88.1.1.1.1.12 |
coCdlRxInvalidFlowIDro Counter32 .1.3.6.1.4.1.9.10.88.1.1.1.1.13 |
coCdlRxInvalidFlowIDOverflowro Counter32 .1.3.6.1.4.1.9.10.88.1.1.1.1.14 |
coCdlHCRxInvalidFlowIDro Counter64 .1.3.6.1.4.1.9.10.88.1.1.1.1.15 |
coCdlRxNonCdlPacketsro Counter32 .1.3.6.1.4.1.9.10.88.1.1.1.1.16 |
coCdlRxNonCdlPacketsOverflowro Counter32 .1.3.6.1.4.1.9.10.88.1.1.1.1.17 |
coCdlHCRxNonCdlPacketsro Counter64 .1.3.6.1.4.1.9.10.88.1.1.1.1.18 |
coCdlDefectIndNotifyEnablerw Enumeration .1.3.6.1.4.1.9.10.88.1.1.2 |
coCdlDefectIndSetSoakIntervalrw Unsigned32 .1.3.6.1.4.1.9.10.88.1.1.3 |
coCdlDefectIndClearSoakIntervalrw Unsigned32 .1.3.6.1.4.1.9.10.88.1.1.4 |
coCdlDINotifyThrottleIntervalrw Unsigned32 .1.3.6.1.4.1.9.10.88.1.1.5 |
coCdlFlowTermGroup OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.88.1.2 |
coCdlFlowTermTable SEQUENCE OF CoCdlFlowTermEntry .1.3.6.1.4.1.9.10.88.1.2.1 |
coCdlFlowTermEntry CoCdlFlowTermEntry .1.3.6.1.4.1.9.10.88.1.2.1.1 |
coCdlFromCdlNetFlowIdentifierrw CoCdlFlowIdentifier .1.3.6.1.4.1.9.10.88.1.2.1.1.1 |
coCdlToCdlNetFlowIdentifierrw CoCdlFlowIdentifier .1.3.6.1.4.1.9.10.88.1.2.1.1.2 |
coCdlFromCdlNetFlowDICurrStatusro CoCdlFlowDefectIndStatus .1.3.6.1.4.1.9.10.88.1.2.1.1.3 |
coCdlFromCdlNetFlowDILastChangero TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.9.10.88.1.2.1.1.4 |
coCdlToCdlNetFlowDICurrStatusro CoCdlFlowDefectIndStatus .1.3.6.1.4.1.9.10.88.1.2.1.1.5 |
coCdlToCdlNetFlowDILastChangero TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.9.10.88.1.2.1.1.6 |
coCdlFromCdlNetEthernetCRCro Counter32 .1.3.6.1.4.1.9.10.88.1.2.1.1.7 |
coCdlFromCdlNetEthernetCRCOvrflwro Counter32 .1.3.6.1.4.1.9.10.88.1.2.1.1.8 |
coCdlFromCdlNetHCEthernetCRCro Counter64 .1.3.6.1.4.1.9.10.88.1.2.1.1.9 |
coCdlMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.88.3 |
coCdlMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.88.3.1 |
coCdlMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.10.88.3.2 |
CISCO-CDL-MIB Technical Reference Overview
The CISCO-CDL-MIB SNMP MIB module published by Cisco defines 45 managed OID objects, including 31 scalar/column metrics, 2 SNMP tables, and 2 trap/notification events anchored at base OID .1.3.6.1.4.1.9.10.88. Key tabular structures include coCdlIntfTable, coCdlFlowTermTable. Monitored SNMP traps/notifications include coCdlRxAggDefectIndChange, coCdlFromCdlNetFlowDIChange.
Key OID Definitions in CISCO-CDL-MIB
.1.3.6.1.4.1.9.10.88This MIB module defines objects to manage Converged Data Link (CDL). CDL provides OAM&P (Operation, Administration, Maintenance and Provisioning) in Ethernet packet-based optical networks without a SONET/SDH layer. The CDL functionality can be divided into the following categories: APS/Defect Indications: The CDL frame carries defect indication bits and provides signalling mechanism support for automatic protection switching. Message Channel: The message channel is used to carry control (e.g. routing, signalling) and management traffic. Packet-by-packet multiplexing of multiple data flows: CDL uses one or two octets to identify the elementary packet stream that this packet belongs to. This allows more than one elementary packet stream to share the bandwidth on a CDL enabled interface. This MIB defines objects to manage Defect Indications and the Packet-by-packet Multiplexing feature. The CDL Message channel is modeled as a separate interface and should be controlled using the IF-MIB and other MIBs for managing IP. This MIB does not provide a mechanism to manage the CDL message channel. APS configuration and monitoring can be done using the CISCO-APS-MIB and CISCO-APS-EXT-MIB.
.1.3.6.1.4.1.9.10.88.1.1.1This table provides objects to configure and monitor CDL on an Ethernet interface.
.1.3.6.1.4.1.9.10.88.1.2.1This table contains objects used to manage logical or physical interfaces representing elementary packet streams at the point where the CDL path defect indications are terminated. Typically, this is a point where the CDL Ethernet encapsulation is applied and removed. This can also be a point between a part of the CDL network that supports packet-by-packet multiplexing, and a part of the CDL network that does not support packet-by-packet multiplexing. Several elementary packet streams (from multiple logical or physical path terminating interfaces) may be multiplexed into an aggregate packet stream before being transmitted out of this network element, towards the rest of the CDL network. (1) + : | + : | + (N) + In the figure above, interface 'A' aggregates the elementary packet streams from interfaces '1' through 'N'. A row in this table exists for each path terminating interface carrying an elementary packet stream. In the figure above, these interfaces are labeled '1' through 'N'. The relationship between the aggregating interface 'A' and an interface carrying an elementary packet stream is not specified in this table. It could be derived from the ifstackTable, or from a cross connect MIB supported by the platform, or from any other means suitable to the platform.
.1.3.6.1.4.1.9.10.88.0.1This notification is sent when the value of the hop-by-hop forward defect indication (FDI-H), hop-by-hop backward defect indication (BDI-H), or end-to-end (aggregate path) forward defect indication (FDI-E) bit received on an interface changes. To minimize the probability of prematurely reacting to momentary signal variations, a soak time may be incorporated into the notification in the following manner. A notification is generated after a defect is first detected, when the defect persists for a period of time that exceeds the set soak interval specified by coCdlDefectIndSetSoakInterval. A notification is generated after a defect stops being detected, when the defect does not appear over a period of time that exceeds the clear soak interval specified by coCdlDefectIndClearSoakInterval. When changes in CDL defect indications are received for multiple interfaces within a short time span, notifications should be deferred so that each notification is generated at least one coCdlDINotifyThrottleInterval after the previous notification.
.1.3.6.1.4.1.9.10.88.0.2This notification is sent when the value of the received end-to-end path forward defect indication or the received end-to-end path backward defect indication changes. Note that the end-to-end path forward defect indication is implicit, i.e. it is not signalled using a bit. An end-to-end path forward defect is inferred when no CDL Ethernet or Idle packets are received over a pre-determined length of time. To minimize the probability of prematurely reacting to momentary signal variations, a soak time may be incorporated into the notification in the following manner. A notification is generated after a defect is first detected, when the defect persists for a period of time that exceeds the set soak interval specified by coCdlDefectIndSetSoakInterval. A notification is generated after a defect stops being detected, when the defect does not appear over a period of time that exceeds the clear soak interval specified by coCdlDefectIndClearSoakInterval. When changes in CDL defect indications are received for multiple interfaces within a short time span, notifications should be deferred so that each notification is generated at least one coCdlDINotifyThrottleInterval after the previous notification.
.1.3.6.1.4.1.9.10.88.1.1.2This object indicates whether a change in the received CDL Defect Indications, including the implicit end-to-end path defect indication as well as the CDL defect indication bits in the CDL OAM field, causes a notification to be generated. disabled: Received CDL aggregate defect indication bit changes do not cause coCdlRxAggDefectIndChange notifications to be generated, and CDL flow defect indication changes from the CDL network at path terminating interfaces do not cause coCdlFromCdlNetFlowDIChange notifications to be generated. enabledAtTerminatingInterfaces: A coCdlRxAggDefectIndChange notification is generated whenever - the received hop-by-hop forward defect indication (FDI-H) or the received hop-by-hop backward defect indication bit (BDI-H) changes at a hop terminating interface, or - the received end-to-end (aggregate path) defect indication bit (FDI-E) changes at an aggregate path terminating interface. A coCdlFromCdlNetFlowDIChange notification is generated whenever a CDL flow defect indication, i.e. implicit end-to-end path forward defect indication or end-to-end path backward defect indication bit, from the CDL network changes at a path terminating interface. enabledAtAllInterfaces: a coCdlRxAggDefectIndChange notification is generated whenever a received CDL aggregate defect indication bit changes on any interface, and a coCdlFromCdlNetFlowDIChange notification is generated whenever a CDL flow defect indication, i.e. implicit end-to-end path forward defect indication or end-to-end path backward defect indication bit, from the CDL network changes at a path terminating interface. To minimize the probability of prematurely reacting to momentary signal variations, a soak time may be incorporated into the notification in the following manner. A notification is generated after a defect is first detected, when the defect persists for a period of time that exceeds the set soak interval specified by coCdlDefectIndSetSoakInterval. A notification is generated after a defect stops being detected, when the defect does not appear over a period of time that exceeds the clear soak interval specified by coCdlDefectIndClearSoakInterval. When changes in CDL defect indications are received for multiple interfaces within a short time span, notifications should be deferred so that each notification is generated at least one coCdlDINotifyThrottleInterval after the previous notification.
.1.3.6.1.4.1.9.10.88.1.1.3To minimize the probability of prematurely reacting to momentary signal variations, a soak time may be incorporated into the defect indications. The indication is set when the defect persists for a period of time that exceeds the set soak interval.
.1.3.6.1.4.1.9.10.88.1.1.4To minimize the probability of prematurely reacting to momentary signal variations, a soak time may be incorporated into the defect indications. The indication is cleared when no defect occurs over a period of time that exceeds the clear soak interval.
.1.3.6.1.4.1.9.10.88.1.1.5The minimum time interval between generation of successive CDL defect indication 'notification-events' by this agent. A 'notification-event' is the transmission of a single trap or inform PDU to a list of notification destinations. If more than one change occurs within a short time span, for for example if hop-by-hop forward defect indications are received for multiple interfaces, then notification-events for these changes should be deferred by the agent so that each notification-event occurs at least one throttle interval after the previous notification-event. At the end of each throttle interval, one notification-event should be generated if the current defect indication state on any interface is different from the last state indicated in a notification-event. In such a case, another throttle interval is started immediately.
.1.3.6.1.4.1.9.10.88.1.1.1.1An entry in the CDL Interface Table, providing objects to configure and monitor CDL on an Ethernet interface. An entry exists for each CDL capable Ethernet interface.
.1.3.6.1.4.1.9.10.88.1.1.1.1.1Enables/disables CDL on this interface. When this object is set to 'true', CDL is enabled on this interface. When this object is set to 'false', CDL is disabled on this interface. When CDL is enabled, the following actions are taken: 1) When a non-CDL packet is progressed to this interface for transmission, the Ethernet packet is modified to carry the CDL header. Similarly, when a received packet is progressed from this interface to a non-CDL interface, the CDL header is removed from the Ethernet packet. 2) Processing of CDL defect indications is activated. 3) The CDL Message Channel used to carry control (e.g. routing, signalling) and management traffic is activated. The SNMP agent creates an interface that represents the CDL Message Channel. The interface representing the CDL Message Channel is shown as a higher layer interface, with ifType 'propPointToPointSerial', residing above this CDL enabled interface in the ifStackTable in the IF-MIB. 4) The CDL APS Channel is activated, if supported and APS is configured for this interface. 5) Transport of multiple data flows (i.e. packet-by-packet multiplexing) is activated, if this capability is supported on this interface. When CDL is disabled, only traditional (non-CDL) Ethernet packets are transported, all packets on this interface are treated as one Ethernet data flow, and the interface representing the CDL message channel is deleted.
.1.3.6.1.4.1.9.10.88.1.1.1.1.2When set to 'true', this object forces CDL Hop Terminating behavior at this interface. A CDL Hop Terminating Network Element terminates (generates in one direction and consumes in another direction) hop-by-hop CDL Defect Indications at an interface. When this object is set to 'false', this network element may still act as a CDL Hop Terminating Network Element at this interface, if either 1) Automatic Protection Switching (APS) has been configured for this interface, or 2) this network element is an Aggregate Path Terminating Network Element at this interface. It is recommended to force CDL Hop Terminating behavior at administrative boundaries. This ensures that the hop-by-hop CDL Defect Indications (FDI-H and BDI-H) between two administrative domains reflect only errors that occur between the domains, even if APS is not configured for this interface.
.1.3.6.1.4.1.9.10.88.1.1.1.1.3This object indicates the current CDL defect indication behavior of this network element, at this interface. A network element can take on one of three roles at a CDL enabled interface: Aggregate Path Terminating Network Element (endOfAggPath), Hop Terminating Network Element (endOfHop), or CDL Regenerator.
.1.3.6.1.4.1.9.10.88.1.1.1.1.4This object reflects the current status of the CDL Defect Indication bits received on this interface.
.1.3.6.1.4.1.9.10.88.1.1.1.1.5This object specifies the value of sysUpTime at the last time there was a change in the value of coCdlRxAggDefectIndCurrStatus.
.1.3.6.1.4.1.9.10.88.1.1.1.1.6This object reflects the current status of the CDL Defect Indication bits transmitted on this interface.
.1.3.6.1.4.1.9.10.88.1.1.1.1.7This object specifies the value of sysUpTime at the last time there was a change in the value of coCdlTxAggDefectIndCurrStatus.
.1.3.6.1.4.1.9.10.88.1.1.1.1.8A CDL enabled interface can aggregate packet streams (called elementary packet streams) from multiple interfaces. CDL uses one or two octets to identify the elementary packet stream that this packet belongs to (called the flow identifier). This object identifies the maximum value that can be assigned to the CDL flow identifier for a packet transmitted on this interface.
.1.3.6.1.4.1.9.10.88.1.1.1.1.9A CDL enabled interface can aggregate packet streams (called elementary packet streams) from multiple interfaces. CDL uses one or two octets to identify the elementary packet stream that this packet belongs to (called the flow identifier). This object identifies the maximum value that can be assigned to the CDL flow identifier for a packet received on this interface.
.1.3.6.1.4.1.9.10.88.1.1.1.1.10The number of CDL frames received with CDL Header CRC errors. This object represents the lower word value of the counter associated with the number of CDL header CRC errors encountered in the receive direction. NOTE: The object coCdlRxHeaderCRCErrorOverflow contains the higher 32 bits of this counter value. SNMP v2c or v3 managers can use the coCdlHCRxHeaderCRCError object directly which is a 64 bit counter.
.1.3.6.1.4.1.9.10.88.1.1.1.1.11This object represents the higher word value of the counter associated with the number of CDL Header CRC errors encountered in the receive direction. NOTE: The object coCdlRxHecError contains the lower 32 bits of this counter value. If the error count is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can use the coCdlHCRxHeaderCRCError object directly which is a 64 bit counter.
.1.3.6.1.4.1.9.10.88.1.1.1.1.12The number of CDL frames received with CDL Header CRC errors. This is a High Capacity (64 bit) version of the coCdlRxHeaderCRCError counter.
.1.3.6.1.4.1.9.10.88.1.1.1.1.13This object counts the number of CDL Flow Identifier lookup errors in the receive direction. When a CDL interface multiplexes/demultiplexes more than one elementary packet stream, it uses the flow identifier in the CDL header. This error counter is incremented when a flow identifier value received on this interface does not map to any of the elementary packet streams demultiplexed by this interface. This object represents the lower word value of the counter associated with the number of CDL Flow Identifier lookup errors encountered in the receive direction. NOTE: The object coCdlRxInvalidFlowIDOverflow contains the higher 32 bits of this counter value. SNMP v2c or v3 managers can use the coCdlHCRxInvalidFlowID object directly which is a 64 bit counter.
.1.3.6.1.4.1.9.10.88.1.1.1.1.14This object represents the higher word value of the counter associated with the number of CDL Flow Identifier lookup errors encountered in the receive direction. NOTE: The object coCdlRxInvalidFlowID contains the lower 32 bits of this counter value. If the error count is greater than 4,294,967,295, the higher word value will be stored in this object. SNMP v2c or v3 managers can use the coCdlHCRxInvalidFlowID object directly which is a 64 bit counter.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.