CISCO-C8500-REDUNDANCY-MIB

AI MIB Summary

The CISCO-C8500-REDUNDANCY-MIB monitors and manages the 1+1 redundancy state of CPU cards and the 2+1 redundancy state of ATM switch fabric cards within the Catalyst 8540 and compatible chassis-based switches. It tracks the operational status and failover readiness of these critical hardware components to ensure continuous switching fabric availability.

This MIB allows management of redundancy of CPU and switch cards for the Catalyst 8540 switch, and other products with similar implementations. The Catalyst 8540 is an ATM switch. It has 13 (or, in some models, 14) slots, of which 2 slots can hold CPU cards, and 3 (or, in some models, 4) slots can hold switch cards. A switch card is one that contains the ATM switching fabric. Two switch cards are combined to operate in 20Gbps switching mode. For CPU cards, 1+1 redundancy is supported. For switch cards, 2+1 redundancy is supported.
Main OID:
ciscoC8500RedundancyMIB.1.3.6.1.4.1.9.9.105
33
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

33 total
Object Name
ciscoC8500RedundancyMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.105
ciscoC8500RedundancyMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.105.1
ccrCpu
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.105.1.1
ccrCpuTable
SEQUENCE OF CcrCpuEntry
.1.3.6.1.4.1.9.9.105.1.1.1
ccrCpuEntry
CcrCpuEntry
.1.3.6.1.4.1.9.9.105.1.1.1.1
ccrCpuSlotIndex
RedundancySlotIndex
.1.3.6.1.4.1.9.9.105.1.1.1.1.1
ccrCpuModerw
RedundancyMode
.1.3.6.1.4.1.9.9.105.1.1.1.1.2
ccrCpuStatusro
RedundancyStatus
.1.3.6.1.4.1.9.9.105.1.1.1.1.3
ccrSyncConfigOnSetrw
Bits
.1.3.6.1.4.1.9.9.105.1.1.2
ccrCpuStandbyEnableModerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.105.1.1.3
ccrCpuSwitchoverTimero
INTEGER
.1.3.6.1.4.1.9.9.105.1.1.4
ccrForceCounterSyncrw
Enumeration
.1.3.6.1.4.1.9.9.105.1.1.5
ccrIfCounterSyncFreqrw
INTEGER
.1.3.6.1.4.1.9.9.105.1.1.6
ccrVcCounterSyncFreqrw
INTEGER
.1.3.6.1.4.1.9.9.105.1.1.7
ccrSigCounterSyncEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.105.1.1.8
ccrSwitch
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.105.1.2
ccrSwitchTable
SEQUENCE OF CcrSwitchEntry
.1.3.6.1.4.1.9.9.105.1.2.1
ccrSwitchEntry
CcrSwitchEntry
.1.3.6.1.4.1.9.9.105.1.2.1.1
ccrSwitchSlotIndex
RedundancySlotIndex
.1.3.6.1.4.1.9.9.105.1.2.1.1.1
ccrSwitchModerw
RedundancyMode
.1.3.6.1.4.1.9.9.105.1.2.1.1.2
ccrSwitchStatusro
RedundancyStatus
.1.3.6.1.4.1.9.9.105.1.2.1.1.3
ccrSwitchLastSwitchoverTimero
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.9.9.105.1.2.2
ccrSwitchLastSwitchoverReasonro
Enumeration
.1.3.6.1.4.1.9.9.105.1.2.3
ccrSwitchBwro
Enumeration
.1.3.6.1.4.1.9.9.105.1.2.4
ccrDesiredSwitchBwrw
Enumeration
.1.3.6.1.4.1.9.9.105.1.2.5
ciscoC8500RedundancyMIBNotificationPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.105.2
ccrMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.105.2.0
ccrCpuStatusChange
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.105.2.0.1
ccrSwitchStatusChange
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.105.2.0.2
ccrSwitchModeChange
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.105.2.0.3
ciscoC8500RedundancyMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.105.3
ciscoC8500RedundancyMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.105.3.1
ciscoC8500RedundancyMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.105.3.2

CISCO-C8500-REDUNDANCY-MIB Technical Reference Overview

The CISCO-C8500-REDUNDANCY-MIB SNMP MIB module published by Cisco defines 33 managed OID objects, including 17 scalar/column metrics, 2 SNMP tables, and 3 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.105. Key tabular structures include ccrCpuTable, ccrSwitchTable. Monitored SNMP traps/notifications include ccrCpuStatusChange, ccrSwitchStatusChange, ccrSwitchModeChange.

Key OID Definitions in CISCO-C8500-REDUNDANCY-MIB

ciscoC8500RedundancyMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.105

This MIB allows management of redundancy of CPU and switch cards for the Catalyst 8540 switch, and other products with similar implementations. The Catalyst 8540 is an ATM switch. It has 13 (or, in some models, 14) slots, of which 2 slots can hold CPU cards, and 3 (or, in some models, 4) slots can hold switch cards. A switch card is one that contains the ATM switching fabric. Two switch cards are combined to operate in 20Gbps switching mode. For CPU cards, 1+1 redundancy is supported. For switch cards, 2+1 redundancy is supported.

ccrCpuTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.105.1.1.1

There is an entry in this table for each slot that can hold a CPU card.

ccrSwitchTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.105.1.2.1

There is an entry in this table for each slot that can hold a switch card. A 'switch card' is a card that contains the ATM switch fabric.

ccrCpuStatusChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.105.2.0.1

This notification is generated when the value of ccrCpuStatus changes for a CPU card. The varbind indicates the current status of the affected card.

ccrSwitchStatusChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.105.2.0.2

This notification is generated when the value of ccrSwitchStatus changes for a switch card. The varbind indicates the current status of the affected card.

ccrSwitchModeChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.105.2.0.3

This notification is generated when the value of ccrSwitchMode changes from active(1) to either standby(2) or unused(3) or notPresent(4). The varbind indicates the current mode of the affected card.

ccrSyncConfigOnSetBITSread-write
.1.3.6.1.4.1.9.9.105.1.1.2

The device's running-configuration and startup-configuration both reside on the active CPU card. This object indicates whether these configurations should be copied from the active CPU to the standby CPU whenever they change. It is acceptable to copy either, both, or neither.

ccrCpuStandbyEnableModeTruthValueread-write
.1.3.6.1.4.1.9.9.105.1.1.3

This object is used to allow or disallow the execution of the enable exec command on the secondary CPU. When set to 'true', the enable exec command can be executed on secondary CPU, and the user may enter enable mode after keying in the password configured. When set to 'false', the enable exec command cannot be executed; thus, no user may enter enabled mode.

ccrCpuSwitchoverTimeINTEGERread-only
.1.3.6.1.4.1.9.9.105.1.1.4

The time taken for the most recent CPU switchover.

ccrForceCounterSyncINTEGERread-write
.1.3.6.1.4.1.9.9.105.1.1.5

This object is used to force the synchronization of counters from primary CPU to secondary CPU. It should generally be set just before a controlled Route Processor Switchover. When this object is retrieved, the value 'noop' is returned. When this object is set to 'noop' no operation is performed.

ccrIfCounterSyncFreqINTEGERread-write
.1.3.6.1.4.1.9.9.105.1.1.6

This object configures the periodicity of interface counter synchronization from primary CPU to secondary CPU. Setting this object to 0 will disable counter synchronization.

ccrVcCounterSyncFreqINTEGERread-write
.1.3.6.1.4.1.9.9.105.1.1.7

This object configures the periodicity of Virtual Circuit (VC) counter synchronization from primary CPU to secondary CPU. Setting this object to 0 will disable counter synchronization.

ccrSigCounterSyncEnableTruthValueread-write
.1.3.6.1.4.1.9.9.105.1.1.8

This object configures the synchronization of ATM Signalling Statistics from primary CPU to secondary CPU. When this object is set to 'true', sychronization is enabled. When this object is set to 'false', synchronization is disabled.

ccrSwitchLastSwitchoverTimeTimeStampread-only
.1.3.6.1.4.1.9.9.105.1.2.2

The value of sysUpTime at the last switchover of the switch cards. The value is zero if there was no switchover since agent initialization.

ccrSwitchLastSwitchoverReasonINTEGERread-only
.1.3.6.1.4.1.9.9.105.1.2.3

The reason for the last switch card switchover. The value is none(1) if there was no switchover since agent initialization.

ccrSwitchBwINTEGERread-only
.1.3.6.1.4.1.9.9.105.1.2.4

The switching capacity (i.e., bandwidth) of the switch fabric. tenGbps(1) - 10 Gigabits/sec twentyGbps(2) - 20 Gigabits/sec.

ccrDesiredSwitchBwINTEGERread-write
.1.3.6.1.4.1.9.9.105.1.2.5

The desired switching capacity (i.e., bandwidth) of the switch fabric. tenGbps(1) - 10 Gigabits/sec twentyGbps(2) - 20 Gigabits/sec If the value configured by writing to this object is supported by the device, it will be applied at the next reboot. The speed at which the switch fabric is currently operating is reflected by the value of ccrSwitchBw.

ccrCpuEntryCcrCpuEntrynot-accessible
.1.3.6.1.4.1.9.9.105.1.1.1.1

Redundancy information for a CPU card.

ccrCpuSlotIndexRedundancySlotIndexnot-accessible
.1.3.6.1.4.1.9.9.105.1.1.1.1.1

Identifies a chassis slot.

ccrCpuModeRedundancyModeread-write
.1.3.6.1.4.1.9.9.105.1.1.1.1.2

The redundancy mode of this CPU card.

ccrCpuStatusRedundancyStatusread-only
.1.3.6.1.4.1.9.9.105.1.1.1.1.3

The operational status of this CPU card.

ccrSwitchEntryCcrSwitchEntrynot-accessible
.1.3.6.1.4.1.9.9.105.1.2.1.1

Redundancy information for a switch card.

ccrSwitchSlotIndexRedundancySlotIndexnot-accessible
.1.3.6.1.4.1.9.9.105.1.2.1.1.1

Identifies a chassis slot.

ccrSwitchModeRedundancyModeread-write
.1.3.6.1.4.1.9.9.105.1.2.1.1.2

The redundancy mode of this switch card.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→