The CISCO-C2900-MIB provides SNMP access to monitor and manage hardware-specific telemetry, including interface statistics, system resources, and environmental sensors, on Cisco Catalyst 2900 series enterprise switches.

The MIB module for Catalyst 2900 enterprise specific information
Main OID:
ciscoC2900MIB.1.3.6.1.4.1.9.9.87
97
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

97 total
Object Name
ciscoC2900MIBThe MIB module for Catalyst 2900 enterprise specific information
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.87
c2900MIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.87.1
c2900SysInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.87.1.1
c2900InfoBoardRevisionReturns the revision number of the main board on which the FastSwitch firmware resides.ro
Gauge32
.1.3.6.1.4.1.9.9.87.1.1.1
c2900InfoPeakBuffersUsedThe maximum number of 64-byte buffers used in the main switch buffer pool.ro
Gauge32 UNITS "buffers"
.1.3.6.1.4.1.9.9.87.1.1.2
c2900InfoTotalBufferDepthIt represents the total number of 64-byte buffers in the Ethernet Controller.ro
Gauge32 UNITS "buffers"
.1.3.6.1.4.1.9.9.87.1.1.3
c2900InfoAddrCapacityThe system-wide maximum number of MAC addresses supported in the address table, a primary resource when forwarding frames through a bridge. The address table is dynamically updated with new learned addresses inserted and aged addresses removed. The address capacity represented by this object includes dynamic, secure, and static address types. To ensure optimal performance, the number of MAC addresses in the bridged local area network to which this bridge is connected should be less than the value of this object. The system administrator can refer to this object for the number of MAC addresses suppored by this box.ro
Gauge32
.1.3.6.1.4.1.9.9.87.1.1.4
c2900InfoRestrictedStaticAddrCapacityThe system-wide maximum number of static addresses supported. A static address is one that has explicit source port filtering information assigned. This number limits the static table's entries configured by user.ro
Gauge32
.1.3.6.1.4.1.9.9.87.1.1.5
c2900InfoSelfTestFailedA bit array where the presence of a particular bit indicates a failure of a specific Power On Self Test. Bit 0 - System Board Failure Bit 1 - CPU Buffer Failure Bit 2 - Notify RAM Failure Bit 3 - Supervisor ASIC Failure Bit 4 - Data Buffer Failure Bit 5 - Buffer Table Failure Bit 6 - Satellite ASIC Failure Bit 7 - Front End Failurero
Bits
.1.3.6.1.4.1.9.9.87.1.1.6
c2900InfoUtilDisplayThe number of utilization meter LEDs currently lit on the front panel, if the value of c2900InfoVisualIndicatorMode is selected as utilization(4). More LEDs are lit as more total bandwidth through the switch is being utilized. The percentage of the utilization is calculated as follows: the number of LEDs lit/the total number of LEDs. The total number of the LEDs is twenty four for c2900 switch. c2900InfoVisualIndicatorMode is utilization(4). If the value of c2900InfoVisualIndicatorMode is not utilization(4), the value of the object will be zero.ro
Gauge32
.1.3.6.1.4.1.9.9.87.1.1.7
c2900InfoVisualIndicatorModeThis object reflects what is currently selected as the visual indication mode, selected by the mode button. The portStatus(1) mode uses the visual LEDS to indicate port link status. The fullDuplex(2) mode uses the visual LEDS to indicate that a port is running with full duplex or half duplex or no link status. The linkRate(3) mode uses the visual LEDS to indicate the rate of operation on a port: 100 MBPS or 10 MBPS or no link. The utilization(4) mode uses the visual LEDS to indicate the utiliztion of the system as more total bandwidth through the switch is being utilized, more LED's are lit.ro
Enumeration
.1.3.6.1.4.1.9.9.87.1.1.8
c2900InfoRedunantPowerSupplyInfoThe switch allows a redundant power supply in addition to its local power supply. Only one power source can be supplying power to a unit. absent(1) :the redundant power supply is not connected to the switch. connectedFunctional(2) : the redundant power supply is connected to the switch and operational. connectedNotFunctional(3): the redundant power supply is connected to the switch, but cannot supply power to the system. functionalPrimaryFailed(4): the redundant power supply is installed, powered on, and operational, but a failure exists in the local power supply system.ro
Enumeration
.1.3.6.1.4.1.9.9.87.1.1.9
c2900InfoBoardIdentifierReturns the identifier of the main board on which the FastSwitch firmware resides.ro
Gauge32
.1.3.6.1.4.1.9.9.87.1.1.10
c2900SysConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.87.1.2
c2900ConfigAddressViolationActionIndicates what action to take when an address violation (an address mismatch or duplication) occurs on a secure port. The default action is to do nothing. doNothing(1) : do nothing disablePort(2) : disable port; the port can only be reenabled by an explicit management action. sendNotify(3) : generate address violation notification. disablePortAndNotify(4): disable port and send notification. Default value: doNothing(1). This object is deprecated. A separate object c2900PortAddressViolationAction is defined for each port.rwdeprecated
Enumeration
.1.3.6.1.4.1.9.9.87.1.2.1
c2900ConfigBroadcastStormAlarmWhen set to true(1), the switch will generate a broadcastStorm notification upon detecting a port is receiving broadcast packets at a rate higher than or equal to the specified broadcast threshold. When set to false(2), no such trap will be issued. Default value: false(2). This object is deprecated. A separate object c2900PortBroadcastStormAlarm is defined for each port.rwdeprecated
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.2.2
c2900ModuleTableA list of module entries.
SEQUENCE OF C2900ModuleEntry
.1.3.6.1.4.1.9.9.87.1.3
c2900ModuleEntryEntry containing status information about one module in the c2900 chassis.
C2900ModuleEntry
.1.3.6.1.4.1.9.9.87.1.3.1
c2900ModuleIndexModule index into c2900ModuleTable .
Integer32
.1.3.6.1.4.1.9.9.87.1.3.1.1
c2900ModuleStatusThe overall status of of the module.ro
Enumeration
.1.3.6.1.4.1.9.9.87.1.3.1.2
c2900ModuleTypeThe type of module installed in malibu switch.ro
Enumeration
.1.3.6.1.4.1.9.9.87.1.3.1.3
c2900ModuleHwVersionThe hardware version of the module. The format of the version string x.y.z where x,y, and z are hardware register field values.ro
DisplayString
.1.3.6.1.4.1.9.9.87.1.3.1.4
c2900ModuleSwVersionThe software version of the module.ro
DisplayString
.1.3.6.1.4.1.9.9.87.1.3.1.5
c2900Port
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.87.1.4
c2900PortTableA list of port entries. The number of entries is determined by the number of modules in the chassis and the number of ports on each module.
SEQUENCE OF C2900PortEntry
.1.3.6.1.4.1.9.9.87.1.4.1
c2900PortEntryEntry containing information for a particular switched port on a module installed. The entries are not created or deleted by management commands.
C2900PortEntry
.1.3.6.1.4.1.9.9.87.1.4.1.1
c2900PortModuleIndexAn index value that uniquely identifies the module where this port is located. The value is determined by the chassis slot number into which the module is plugged.
Integer32
.1.3.6.1.4.1.9.9.87.1.4.1.1.1
c2900PortIndexAn index value that uniquely identifies this port within a module.
Integer32
.1.3.6.1.4.1.9.9.87.1.4.1.1.2
c2900PortUsageApplicationThis object indicates how the port is to be used. The variable usage applications are shown above. These applications are defined such that they are mutually exclusive. In other words, a port using the security(2) application cannot also use the monitor(3) application at the same time. The default usage is standard(1), or no special behavior (the port behaves as normal switched port). The security(2) usage adds addressing security to the port, whereby all learned addresses are secure address. The monitor(3) usage provides network diagnosis by reflecting traffic on other ports to this port. The portGrouping(4) application treats this and other ports in the same group as one(inter-switch) connection for more bandwidth potential. When the c2900PortUsageApplication is portGrouping, the c2900PortGroupIndex is set to the index value of the port group. The source address of a received frame is used to determine on which port within the group the frame should be transmitted. The network(5) usage saves address table space when the port is used as the link to a large network with many MAC addresses by disabling address learning on the port and allowing unknown unicasts packets received on other ports of the vlan the port associated with to be forwarded only to the port. The networkGroup(6) usage treates this and other ports in the same group as a network port group. All ports in port are network ports in the sense that address learning is disabled on them and unknown unicast packets received on other ports of the vlan are forwarded to the group. The portGroupDest(7) application treats this and other ports in the same group as one(inter-switch) connection for more bandwidth potential. When the c2900PortUsageApplication is portGroupDest, the c2900PortGroupIndex is set to the index value of the port group. The destination address of a received frame is used to determine on which port within the group the frame should be transmitted. The protected(8) application does not forward any traffic to other protected ports. It does not forward all kinds of unicast, multicast and broadcast traffic to any other protected port. The protected ports, however, forward traffic normally to non-protected ports and vice versa.rw
Enumeration
.1.3.6.1.4.1.9.9.87.1.4.1.1.3
c2900PortGroupIndexThis object is meaningful only when the corresponding c2900PortUsageApplication is portGrouping. Ports assigned with the same value of c2900PortGroupIndex belong to the same connection channel.rw
Integer32
.1.3.6.1.4.1.9.9.87.1.4.1.1.4
c2900PortMayLearnAddressThis object reflects an internal state of the port with regard to its ability to learn new addresses. Certain port configurations such as learning time limit, security usage, etc., and some Spanning Tree Protocol states can temporarily prohibit the port from learning. This object is true(1) if the port is allowed to learn. It is false(2) otherwise. Setting this object to true(1) will fail, if the port is not in normal state. This object is deprecated.rwdeprecated
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.4.1.1.5
c2900PortMayForwardFramesThis object reflects an internal state of the port with regard to its ability to forward frames. A port sometimes stops forwarding frames when it is blocked by the Spanning Tree Protocol, or while it is undergoing temporary load balancing as part of the port grouping usage. This object is true(1) if the port is allowed to forward frames. It is false(2) otherwise. Setting this object to true(1) will fail, if the port is in the middle of being blocked by the Spanning Tree Protocol, or while it is undergoing temporary load balancing as part of the port grouping usage. This object is only supported for static VLAN access ports.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.4.1.1.6
c2900PortBufferCongestionControlSeting this object to true(1) allows the switch to run its buffer congestion control algorithm on the port. Setting the object to false(2) disallows such control. The buffer congestion control algorithm is summarized in the description of the c2900PortBufferCongestionThresholdPercent below. This object is deprecatedrodeprecated
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.4.1.1.7
c2900PortBufferCongestionThreshholdPercentThe port buffer congestion threshold provides an early warning to the switch that the port is about to exhaust all its guaranteed buffers, leading to congestion. This threshold is expressed as a percentage of the port's total guaranteed buffer depth. Once this threshold has been crossed, the switch begins colliding with frames received on the port for a fixed period of time. After this time has expired, the switch determines whether the port's buffer congestion has been alleviated. If this situation has not changed, the switch resumes this congestion control algorithm on the port.ro
Integer32
.1.3.6.1.4.1.9.9.87.1.4.1.1.8
c2900PortFrameAgeThe aging interval in milliseconds after which old frames queued for transmission on this port are discarded.ro
Integer32
.1.3.6.1.4.1.9.9.87.1.4.1.1.9
c2900PortAddrSecureMaxAddressesThe maximum number of secure addresses that can be learned on this port when it is a secure port. This number should be always higher than c2900PortAddrSecureCurrentAddressesrw
Integer32
.1.3.6.1.4.1.9.9.87.1.4.1.1.10
c2900PortAddrSecureCurrentAddressesThe current number of statically assigned unicast addresses on the port.ro
Gauge32
.1.3.6.1.4.1.9.9.87.1.4.1.1.11
c2900PortAddrSecureAddrViolationsThe number of times a source address was seen on this port which duplicates a secured address configured on another port, plus the number of times a source address was seen on this port which does not match any addresses secured for the port.ro
Counter32
.1.3.6.1.4.1.9.9.87.1.4.1.1.12
c2900PortNumberOfLearnedAddressesThe current number of dynamically learned addresses on the port.ro
Counter32
.1.3.6.1.4.1.9.9.87.1.4.1.1.13
c2900PortNumberOfDroppedAddressesThe number of times an address could not be learned or assigned for the port because its address table was full at one time.ro
Counter32
.1.3.6.1.4.1.9.9.87.1.4.1.1.14
c2900PortClearAddressesSet to true(1) to delete all learned and assigned dynamic, static and secure unicast addresses the port currently has. Setting the object to false(2) has no effect. This object always returns false(2) when read.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.4.1.1.15
c2900PortFloodUnknownMulticastsSet to true(1) to allow forwarding to this port frames addressed to multicast addresses that have not been configured for the port. Set to false(2) to filter and discard such frames.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.4.1.1.16
c2900PortFloodUnknownUnicastsThis object controls the forwarding of unknown unicast frames to this port. When set to true(1), the switch will, upon receiving a frame with an unknown unicast destination address from another port, transmit the frame to this port. When set to false(2), switch will filter and not transmit said frames to this port. Default value: false(2) for ports using the security or monitor application; true(1) for all other usage applications.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.4.1.1.17
c2900PortLinkbeatStatusThis object depends on the physical layer in use and indicates the current port linkbeat status: if the physical link between two devices is properly connected or not. If the value is linkbeat(1), there is linkbeat. If the value is nolinkbeat(2), there is no linkbeat. If the value is unknown(3), the information is not available.ro
Enumeration
.1.3.6.1.4.1.9.9.87.1.4.1.1.18
c2900PortBroadcastStormActionIndicates what action to take when the broadcast rising threshold for a port is reached. The default action is to forwardBroadcast(2) as usual for all broadcast frames received from the port. The other action is to stopBroadcastForwarding(1) frames until the broadcast reception rate falls to or below the falling threshold. The port can also be shutdown in the event of a broadcast storm with the action disablePort(3).rw
Enumeration
.1.3.6.1.4.1.9.9.87.1.4.1.1.19
c2900PortBroadcastRisingThresholdThe broadcast rising threshold is measured in the number of broadcast frames received on a port in a second. When the number of broadcast frames received per second on this port crosses this threshold, the appropriate action as specified by the object c2900PortBroadcastStormAction will take place. See the description of c2900PortBroadcastStormAction.rw
Gauge32
.1.3.6.1.4.1.9.9.87.1.4.1.1.20
c2900PortBroadcastFallingThresholdThe broadcast falling threshold is measured in number of broadcast frames received on a port in a second. When the falling threshold is crossed and the c2900PortBroadcastStormAction was stopBroadcastForwarding(1) then broadcast forwarding will be re-enabled on the port. For the other values of c2900PortBroadcastStormAction, crossing the falling threshold has no affect.rw
Gauge32
.1.3.6.1.4.1.9.9.87.1.4.1.1.21
c2900PortStatusThe port's current state as defined by application of the Spanning Tree Protocol. This state controls what action a port takes on reception of a frame. If the switch has detected a port that is malfunctioning it will place that port into the broken(10) state. For ports which are disabled(see dot1dStpPortEnable), this object will have a value of disabled(2). Since the switch implements three additional states which are not part of IEEE Standard, these additional states are possible values for c2900PortStaus. The additional states are preforwarding(6), secureforwarding(8), and suspended(9). Note: except for these additional states, this object is the same as the dot1dStpPortState object. Default value: blocking(2). This object is only supported for static VLAN access ports.ro
Enumeration
.1.3.6.1.4.1.9.9.87.1.4.1.1.22
c2900PortTestResultThis object indicates if the port passed power on self test or not. If the value of this object is true(1), the port passed test. If the value of this object is false(2), the port failed test.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.4.1.1.23
c2900PortVisualIndicatorThis object is used to indicate the current color of a LED. If a LED is flashing, the value of this object will represent the color of the LED at that instant in time. The following conventions indicate port status: Link healthy returns green(4) Link activity usually green(4), but may return black(2). Link faulty alternating green(4)/amber(3) Port disabled returns amber(3)ro
Enumeration
.1.3.6.1.4.1.9.9.87.1.4.1.1.24
c2900PortIfIndexThe value of the instance of the ifIndex object, defined in MIB-II, for the interface corresponding to this port.ro
InterfaceIndex
.1.3.6.1.4.1.9.9.87.1.4.1.1.25
c2900PortAddressViolationActionIndicates what action to take when an address violation (an address mismatch or duplication) occurs on a secure port. The default action is to do nothing. doNothing(1) : do nothing disablePort(2) : disable port; the port can only be reenabled by an explicit management action. sendNotify(3) : generate address violation notification. disablePortAndNotify(4): disable port and send notification.rw
Enumeration
.1.3.6.1.4.1.9.9.87.1.4.1.1.26
c2900PortBroadcastStormAlarmWhen set to true(1), the switch will generate a broadcastStorm notification upon detecting a port is receiving broadcast packets at a rate higher than or equal to the threshold specified by c2900PortBroadcastRisingThreshold. When set to false(2), no such trap will be issued. Default value: false(2). c2900PortBroadcastStormAlarm is defined for each port.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.4.1.1.27
c2900PortMonitorDestinationPortSwitch Port (c2900PortSwitchPortIndex) index value of the port that is to be monitored by this port. A value of zero can't be used to do set, it is used to return when this object is read. To remove a port from the monitored list use the object c2900PortNoMonitorDestinationPort.rw
Integer32
.1.3.6.1.4.1.9.9.87.1.4.1.1.28
c2900PortSwitchPortIndexSwitch port index of a port is a value that uniquely identifies the port within a switch. This is obtained from the port index (c2900PortIndex) and the module index (c2900PortModuleIndex).ro
Integer32
.1.3.6.1.4.1.9.9.87.1.4.1.1.29
c2900PortMonitoredPortMapIndicates which ports are actually being monitored. The octet string contains one bit per port. Each bit within the octet string represents one port of the device. The ordering of ports represented within the octet string is in the same order as in the RFC 1493 dot1dStaticAllowedToGoTo in the dot1dStaticTable. The bit value interpretation is as follows: 1 = being monitored 0 = not being monitoredro
OCTET STRING
.1.3.6.1.4.1.9.9.87.1.4.1.1.30
c2900PortDuplexStateSet to fullduplex(1) to operate in full duplex mode, port will allow simultaneous transmit and receive which can double its bandwidth. Set to halfduplex(2) to operate in half duplex mode. Set to autoNegotiate(3) to allow the switch to negoti- ate with the other end of the connection. The status of duplex mode on a port is available with c2900PortDuplexStatus object.rw
Enumeration
.1.3.6.1.4.1.9.9.87.1.4.1.1.31
c2900PortDuplexStatusThe status of duplex mode on this port. When linkbeat is not present, halfduplex is always reported. When linkbeat is present, the result of full duplex auto-negotiation is reported if c2900PortDuplexState is set to auto-negotiate, otherwise it reports fullduplex if c2900PortDuplexState is set to fullduplex or halfduplex if c2900PortDuplexState is set to halfduplex.ro
Enumeration
.1.3.6.1.4.1.9.9.87.1.4.1.1.32
c2900PortAdminSpeedThe object controls the speed of the port. The current operational speed of the port can be determined from ifSpeed.rw
Enumeration
.1.3.6.1.4.1.9.9.87.1.4.1.1.33
c2900PortNoMonitorDestinationPortSwitch Port (c2900PortSwitchPortIndex) index value of the port that is to be removed from the monitored list. A value of zero can't be used to do set, it is used to return when this object is read. To add a port to the monitored list use the object c2900PortMonitorDestinationPort.rw
Integer32
.1.3.6.1.4.1.9.9.87.1.4.1.1.34
c2900Portdot1dBasePortThis is the dot1dBasePort associated with this port.ro
Integer32
.1.3.6.1.4.1.9.9.87.1.4.1.1.35
c2900PortSpantreeFastStartIndicates whether the port is operating in spantree fast start mode. A port with fast start enabled is immediately put in spanning tree forwarding state on link up, rather than starting in blocking state which is the normal operation. This is useful when the port is known to be connected to a single station which has problems waiting for the normal spanning tree operation to put the port in forwarding state.rw
Enumeration
.1.3.6.1.4.1.9.9.87.1.4.1.1.36
c2900PortVoiceVlanIdThe Voice Virtual Vlan ID (VVID) to which this port belongs to. If the VVID is not supported on the port, this MIB object will not be configurable and will return 4096. Setting this MIB object to 4096, the CDP packets transmitting through this port would not include Appliance VLAN-ID TLV. Setting this MIB object to 4095, the CDP packets transmitting through this port would contain Appliance VLAN-ID TLV with value of 4095 - VoIP and related packets are expected to be sent and received untagged without an 802.1p priority. Setting this MIB object to 0, the CDP packets transmitting through this port would contain Appliance VLAN-ID TLV with value of 0 - VoIP and related packets are expected to be sent and received with VLAN-id=0 and an 802.1p priority. Setting this MIB object to N (1..1000), the CDP packets transmitting through this port would contain Appliance VLAN-ID TLV with N - VoIP and related packets are expected to be sent and received with VLAN-id=N and an 802.1p priority.rw
INTEGER ( 0|1..1000|4095|4096 )
.1.3.6.1.4.1.9.9.87.1.4.1.1.37
c2900PortAddrSecureAgingTimeThe aging interval in minutes for each secure address entry on a given port. Depending on the type of aging the secure address will age out after the expiration of the aging time and will be removed from the secure address list. Any change in the value of this object will restart the aging for all the secure addresses on this port. If the value of this object is 0 for a given port, the aging mechanism is disabled for this port.rw
Integer32
.1.3.6.1.4.1.9.9.87.1.4.1.1.38
c2900PortAddrSecureAgingTypeIf the value of this object on a given port is absolute - all the secure addresses on this port will age out exactly after the aging time configured for this port. inactivity - the secure addresses on this port will age out only if there is no data traffic from the given secure source address for a time period specified by aging time. Any change in the value of this object will restart the aging for all the secure addresses on this port. The value of this object is not effective when the value of c2900PortAddrSecureAgingTime is 0.rw
Enumeration
.1.3.6.1.4.1.9.9.87.1.4.1.1.39
c2900PortAddrSecureAgingStaticSet to true(1) to enable aging for statically configured secure addresses on one port. Disable the aging for statically configured secure addresses if set to false(2). Any change in the value of this object will restart the aging for all the configured secure addresses on this port. The value of this object is not effective when the value of c2900PortAddrSecureAgingTime is 0.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.4.1.1.40
c2900PortStatsTableA list of port entries. The number of entries is determined by the number of modules in the chassis and the number of ports on each module.
SEQUENCE OF C2900PortStatsEntry
.1.3.6.1.4.1.9.9.87.1.4.2
c2900PortStatsEntryEntry containing information for a particular switched port on a module installed. The entry cannot be created or deleted.
C2900PortStatsEntry
.1.3.6.1.4.1.9.9.87.1.4.2.1
c2900PortRxNoBwFramesA count of frames received on this port that were discarded due to a lack of bandwidth resources in the Catalyst Switch forwarding engine.ro
Counter32 UNITS "frames"
.1.3.6.1.4.1.9.9.87.1.4.2.1.1
c2900PortRxNoBufferFramesA count of frames received that were discarded due to a lack of frame buffer resources in the Catalyst Switch forwarding engine.ro
Counter32 UNITS "frames"
.1.3.6.1.4.1.9.9.87.1.4.2.1.2
c2900PortRxNoDestUniFramesA count of unicast frames received that were discarded, because the forwarding rules stipulate that they are not be forwarded.ro
Counter32 UNITS "frames"
.1.3.6.1.4.1.9.9.87.1.4.2.1.3
c2900PortRxNoDestMultiFramesA count of multicast frames received that were discarded, because they have not been configured for the port.ro
Counter32 UNITS "frames"
.1.3.6.1.4.1.9.9.87.1.4.2.1.4
c2900PortRxSuppressBcastFramesA count of broadcast frames received that were discarded because of the threshold-based broadcast suppression. This object is deprecated, because there is no way that the Malibu system to give the brodcast_supress framesrodeprecated
Counter32 UNITS "frames"
.1.3.6.1.4.1.9.9.87.1.4.2.1.5
c2900PortRxFcsErrFramesThe total number of frames received with FCS errors. This total includes all frames received with an FCS error and an integral number of bytes. Unlike RFC1650's dot3StatsFCSErrors, this object does not include frames which are less than the minimum packet size (such as collision fragments).ro
Counter32 UNITS "frames"
.1.3.6.1.4.1.9.9.87.1.4.2.1.6
c2900PortCollFragFramesThe total number of frames whose lengths are less than 64 and have bad FCS values. The preamble and sfd fields are excluded from the byte count of a frame while the FCS field is included.ro
Counter32 UNITS "frames"
.1.3.6.1.4.1.9.9.87.1.4.2.1.7
c2900PortTxMulticastFramesA count of frames that are successfully transmitted and are directed to a multicast address. Unlike RFC1573's ifOutMulticastPkts, this object does not include those that were discarded or not sent.ro
Counter32 UNITS "frames"
.1.3.6.1.4.1.9.9.87.1.4.2.1.8
c2900PortTxBroadcastFramesA count of frames that are successfully transmitted and are directed to the broadcast address. Unlike RFC1573's ifOutBroadcastPkts, this object does not include those that were discarded or not sent.ro
Counter32 UNITS "frames"
.1.3.6.1.4.1.9.9.87.1.4.2.1.9
c2900BandwidthUsage
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.87.1.5
c2900BandwidthUsageCurrentThe current bandwidth consumed. The measurement unit is in megabits per second (1,000,000 bits/second). This value gives a reasonable estimate of the amount of traffic currently flowing through the switch. It is calculated as follows: Octets*8 + Frames*(96 + 64) Measurement Interval * 1,000,000 * 2 Where: Measurement Interval is the amount of time over which the Octets and Frames were collected, in seconds. Measurement Interval is always one second in current implementation. Octets is the total number of octets transmitted or received by all network interfaces, excluding framing data but including FCS. This includes octets in frames which were partially transmitted or received (due to collisions, for example). Frames is the total number of frames transmitted or received by all network interfaces, including frames with errors. The number of frames is multiplied by 96 plus 64 in order to estimate the delay between each frame for Ethernet's IPG and preamble/SFD. The '2' in the divisor makes this a forwarding bandwidth counter. A frame received on one interface is typically forwarded out another interface. In order to avoid double- counting this frame's bandwidth, once on the receiving interface and once on the transmitting interface, the total bandwidth is divided by two. Since multicast and broadcast frames can be sent to multiple ports, the above is at best a lower bound.ro
Gauge32 UNITS "megabits per second"
.1.3.6.1.4.1.9.9.87.1.5.1
c2900BandwidthUsageMaxPeakEntriesThe maximum number of entries c2900BandwidthUsagePeakTable can have.ro
Gauge32
.1.3.6.1.4.1.9.9.87.1.5.2
c2900BandwidthUsagePeakIntervalThis object specifies the length of time which forms a peak bandwidth measurement interval. A write to this object with any new value restarts the peak bandwidth recording interval used by bandwidthUsagePeakTable. In other words, the bandwidthUsagePeakTable will be cleared and entry number one will record the peak with a new measurement interval.rw
Enumeration
.1.3.6.1.4.1.9.9.87.1.5.3
c2900BandwidthUsagePeakRestartSet to true(1) to clear the c2900BandwidthUsagePeakTable and restart the peak bandwidth recording. No action will be taken if this object is set to false(2). This object returns false(2) when read.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.5.4
c2900BandwidthUsageCurrentPeakEntryA value identifying an instance of the c2900BandwidthUsagePeakIndex where the peak bandwidth estimation is most recent.ro
Gauge32
.1.3.6.1.4.1.9.9.87.1.5.5
c2900BandwidthUsagePeakTableA list of entries containing peak bandwidth usages in a number of recording interval. After being cleared, entries are added to the bandwidthUsagePeakTable with ascending values of c2900BandwidthUsagePeakIndex starting at 1. When the number of entries reaches c2900BandwidthUsageMaxPeakEntries, each new recording interval is assigned the value of c2900BandwidthUsagePeakIndex corresponding to the oldest entry, overwriting the previous contents of that entry.
SEQUENCE OF C2900BandwidthUsagePeakEntry
.1.3.6.1.4.1.9.9.87.1.5.6
c2900BandwidthUsagePeakEntryInformation about peak bandwidth usage in a recording interval.
C2900BandwidthUsagePeakEntry
.1.3.6.1.4.1.9.9.87.1.5.6.1
c2900BandwidthUsagePeakIndexNumber from one to c2900BandwidthUsageMaxPeakEntries identifying a particular c2900BandwithUsagePeakEntry.ro
Integer32
.1.3.6.1.4.1.9.9.87.1.5.6.1.1
c2900BandwidthUsageStartTimeThe time that marks the start of this recording interval.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.5.6.1.2
c2900BandwidthUsagePeakThe maximum bandwidth usage of any measurement interval within this recording interval. This value is an estimate of the highest amount of traffic flowing through the switch during this recording interval. It is calculated as follows: Octets*8 + Frames*(96 + 64) Measurement Interval * 1,000,000 * 2 Where: Measurement Interval is the amount of time over which the Octets and Frames were collected, in seconds. Measurement Interval is always one second in c2900's implementation. Octets is the total number of octets transmitted or received by all network interfaces, excluding framing data but including FCS. This includes octets in frames which were partially transmitted or received (due to collisions, for example). Frames is the total number of frames transmitted or received by all network interfaces, including frames with errors. The number of frames is multiplied by 96 plus 64 in order to estimate the delay between each frame for Ethernet's IPG and preamble/SFD. The '2' in the divisor makes this a forwarding bandwidth counter. A frame received on one interface is typically forwarded out another interface. In order to avoid double- counting this frame's bandwidth, once on the receiving interface and once on the transmitting interface, the total bandwidth is divided by two. Since multicast and broadcast frames can be sent to multiple ports, the above is at best a lower bound.ro
Gauge32 UNITS "megabits per second"
.1.3.6.1.4.1.9.9.87.1.5.6.1.3
c2900BandwidthUsagePeakTimeThe start time of the measurement interval.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.9.9.87.1.5.6.1.4
c2900MibNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.87.2
c2900MibNotificationsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.87.2.0
c2900AddressViolationThe addressViolation notification is generated when an address violation is detected on a secured port. The generation of the addressViolation notification can be enabled or suppressed using the object c2900ConfigAddressViolationAction. The particular secured port is indicated by the value of c2900PortIfIndex.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.87.2.0.1
c2900BroadcastStormThe broadcastStorm notification is generated upon detecting a port is receiving broadcast packets at a rate crossing the specified broadcast threshold. This trap is only for the rising threshold. The particular port is indicated by the values of c2900PortModuleIndex and c2900PortIndex, and the value of the threshold is given by c2900PortBroadcastRisingThreshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.87.2.0.2
c2900RpsFailedA redundant power system (RPS) is connected to the switch. The RpsFailed notification is generated upon detecting RPS failure.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.87.2.0.3
c2900MIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.87.3
c2900MIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.87.3.1
c2900MIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.87.3.2