Home/Catalog/CISCO-BSC-MIB

CISCO-BSC-MIB

AI MIB Summary

The CISCO-BSC-MIB manages Cisco Binary Synchronous Communications (BSC) implementations by exposing configuration and operational data for BSC serial interfaces and their associated Control Units (stations). It facilitates monitoring of BSTUN routing parameters, specifically mapping BSC Control Unit addresses to the `bstunRouteStationAddress` for traffic routing and session management.

The MIB module for BSC. Overview of BSC MIB MIB description The BSC MIB provides the configuration and operational information on Cisco's Binary Synchronous Communications implementation. The following entities are managed: 1) BSC ports (serial interfaces) 2) BSC Control Units (stations on a port) The BSC ports are identified by the interface index, and additional information about this interface can be obtained from the Cisco Serial Interface MIB. The BSC Control Units are identified by the Control Unit address; this is the address used by BSTUN to route the BSC traffic - it is therefore equivalent to the bstunRouteStationAddress in the bstunRouteTable MIB.
Main OID:
ciscoBscMIB.1.3.6.1.4.1.9.9.36
41
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

41 total
Object Name
ciscoBscMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.36
bscObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.36.1
bscPorts
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.36.1.1
bscPortTable
SEQUENCE OF BscPortEntry
.1.3.6.1.4.1.9.9.36.1.1.1
bscPortEntry
BscPortEntry
.1.3.6.1.4.1.9.9.36.1.1.1.1
bscPortRolero
Enumeration
.1.3.6.1.4.1.9.9.36.1.1.1.1.1
bscPortCodeSetro
Enumeration
.1.3.6.1.4.1.9.9.36.1.1.1.1.2
bscPortPausero
INTEGER
.1.3.6.1.4.1.9.9.36.1.1.1.1.3
bscPortServlimro
INTEGER
.1.3.6.1.4.1.9.9.36.1.1.1.1.4
bscPortPollTimeoutro
INTEGER
.1.3.6.1.4.1.9.9.36.1.1.1.1.5
bscPortRecoveryRetriesro
INTEGER
.1.3.6.1.4.1.9.9.36.1.1.1.1.6
bscPortUnknownControlUnitsReceivedro
Counter32
.1.3.6.1.4.1.9.9.36.1.1.1.1.7
bscPortSoftErrorsro
Counter32
.1.3.6.1.4.1.9.9.36.1.1.1.1.8
bscPortHardErrorsro
Counter32
.1.3.6.1.4.1.9.9.36.1.1.1.1.9
bscPortProtocolViolationsro
Counter32
.1.3.6.1.4.1.9.9.36.1.1.1.1.10
bscPortHostTimeoutro
Integer32
.1.3.6.1.4.1.9.9.36.1.1.1.1.11
bscPortSpecPollro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.36.1.1.1.1.12
bscPortVirtualAddressro
Integer32
.1.3.6.1.4.1.9.9.36.1.1.1.1.13
bscPortContentionDialTimeoutro
Integer32
.1.3.6.1.4.1.9.9.36.1.1.1.1.14
bscControlUnits
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.36.1.2
bscControlUnitTable
SEQUENCE OF BscCUEntry
.1.3.6.1.4.1.9.9.36.1.2.1
bscCUEntry
BscCUEntry
.1.3.6.1.4.1.9.9.36.1.2.1.1
bscCUAddress
INTEGER
.1.3.6.1.4.1.9.9.36.1.2.1.1.1
bscCUStatero
Enumeration
.1.3.6.1.4.1.9.9.36.1.2.1.1.2
bscCUBytesSentro
Counter32
.1.3.6.1.4.1.9.9.36.1.2.1.1.3
bscCUBytesReceivedro
Counter32
.1.3.6.1.4.1.9.9.36.1.2.1.1.4
bscCUTotalFramesSentro
Counter32
.1.3.6.1.4.1.9.9.36.1.2.1.1.5
bscCUTotalFramesReceivedro
Counter32
.1.3.6.1.4.1.9.9.36.1.2.1.1.6
bscCUDataFramesSentro
Counter32
.1.3.6.1.4.1.9.9.36.1.2.1.1.7
bscCUDataFramesReceivedro
Counter32
.1.3.6.1.4.1.9.9.36.1.2.1.1.8
bscCUSoftErrorsro
Counter32
.1.3.6.1.4.1.9.9.36.1.2.1.1.9
bscCUHardErrorsro
Counter32
.1.3.6.1.4.1.9.9.36.1.2.1.1.10
bscCUProtocolViolationsro
Counter32
.1.3.6.1.4.1.9.9.36.1.2.1.1.11
bscExtAddresses
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.36.1.3
bscExtAddressTable
SEQUENCE OF BscExtAddressEntry
.1.3.6.1.4.1.9.9.36.1.3.1
bscExtAddressEntry
BscExtAddressEntry
.1.3.6.1.4.1.9.9.36.1.3.1.1
bscExtPollAddress
Integer32
.1.3.6.1.4.1.9.9.36.1.3.1.1.1
bscExtSelectAddressro
Integer32
.1.3.6.1.4.1.9.9.36.1.3.1.1.2
bscMibConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.36.3
bscMibCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.36.3.1
bscMibGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.36.3.2

CISCO-BSC-MIB Technical Reference Overview

The CISCO-BSC-MIB SNMP MIB module published by Cisco defines 41 managed OID objects, including 27 scalar/column metrics, 3 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.36. Key tabular structures include bscPortTable, bscControlUnitTable, bscExtAddressTable.

Key OID Definitions in CISCO-BSC-MIB

ciscoBscMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.36

The MIB module for BSC. Overview of BSC MIB MIB description The BSC MIB provides the configuration and operational information on Cisco's Binary Synchronous Communications implementation. The following entities are managed: 1) BSC ports (serial interfaces) 2) BSC Control Units (stations on a port) The BSC ports are identified by the interface index, and additional information about this interface can be obtained from the Cisco Serial Interface MIB. The BSC Control Units are identified by the Control Unit address; this is the address used by BSTUN to route the BSC traffic - it is therefore equivalent to the bstunRouteStationAddress in the bstunRouteTable MIB.

bscPortTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.36.1.1.1

A list of port (serial interfaces) which have been configured to support a BSC BSTUN group.

bscControlUnitTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.36.1.2.1

A table containing information about specific Control Units.

bscExtAddressTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.36.1.3.1

List of all addresses configured by the bsc extended-address command. This applies only to interfaces with an ifType of 'bsc'. The address entries must be unique per interface.

bscPortEntryBscPortEntrynot-accessible
.1.3.6.1.4.1.9.9.36.1.1.1.1

Status and parameter values for a port.

bscPortRoleINTEGERread-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.1

The router's DLC role to the attached node. If the bscPortRole is primary, this implies that the port is connected to a remote secondary device. If the role is generic, this indicates that the port will be running framed bisynchronous frames with an unknown protocol. If this object does not have the value 'contention' then bscPortVirtualAddress will not be instantiated. If this object does not have the value 'dialContention' then bscPortContentionDialTimeout will not be instantiated.

bscPortCodeSetINTEGERread-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.2

The code set used for the line controls.

bscPortPauseINTEGERread-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.3

For primary, it is the minimum time to be taken for a cycle round the active poll table; if this time has not elapsed when the bottom of the poll table is reached, then polling will pause until this timer expires. A value of zero means there will be no pause between cycles round the poll table. For secondary, the pause time out is the delay taken before sending a response to a poll when it has no data frame to send. The units are tenths of a second. The default is 10 (1 second).

bscPortServlimINTEGERread-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.4

This parameter is valid for primary only. It is the number of times the active poll table will be cycled before a non-responding control unit will be polled. The default is 3.

bscPortPollTimeoutINTEGERread-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.5

This parameter is valid for primary only. It is the time that the primary will wait for a response to a poll or select. The units are tenths of a second. The default is 10 (1 second).

bscPortRecoveryRetriesINTEGERread-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.6

This is the number of times that a recovery sequence will be retried before the connection is considered to have failed. The default is 5.

bscPortUnknownControlUnitsReceivedCounter32read-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.7

Count of frames received from the serial interface with an unsupported control unit address. If this value is non-zero it indicates a problem in the configuration.

bscPortSoftErrorsCounter32read-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.8

Count of soft errors; these are errors which have been recovered. This includes CRC errors received, frames which were retransmitted for any reason (NAK received or the wrong ACK received), etc. This count is a measure of the quality of the port/line, but should be considered in relation to the amount of traffic on the port (frames or bytes sent and received). This count includes all control unit soft errors on this port, plus errors which were not for a specific control unit.

bscPortHardErrorsCounter32read-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.9

Count of hard errors; these are errors which have not been recovered after bscPortRecoveryRetries number of retries, and therefore the connection has been terminated. These errors could be caused by a hardware error in the line or in the remote device; or possibly the bscPortRecoveryRetries value is set too low for the quality of the line. This count includes all control unit hard errors on this port, plus errors which were not for a specific control unit.

bscPortProtocolViolationsCounter32read-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.10

Count of protocol violations. This counter is incremented when an unexpected BSC Data Link Control character is received from the remote device; that is, the control character is invalid in the current state of the local BSC FSM. This indicates that there is an incompatibility between the two implementations of the BSC protocol. This count includes all control unit protocol violations on this port, plus errors which were not for a specific control unit.

bscPortHostTimeoutInteger32read-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.11

This parameter is valid for interfaces configured secondary which additionally are running local-acknowledgement. If the configuration does not match the value will be shown as zero. It is the time the interface will wait for a poll from the host before putting the CU on the inactive list. The default is 60 seconds.

bscPortSpecPollTruthValueread-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.12

This parameter is valid for primary, local-acknowledgement interfaces only. It is set to TRUE when the interface is configured to treat specific polls as general polls. If the configuration cannot support this value, it will be set to FALSE. The default is FALSE.

bscPortVirtualAddressInteger32read-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.13

This parameter is valid for contention only. It is the address to be used for this interface when the remote peer router is being used as a concentrator. The default is 01.

bscPortContentionDialTimeoutInteger32read-only
.1.3.6.1.4.1.9.9.36.1.1.1.1.14

This parameter is valid for dialContention only. It is the amount of time an interface can be quiescent before return the interface to the dial-in pool. The default is 5 seconds.

bscCUEntryBscCUEntrynot-accessible
.1.3.6.1.4.1.9.9.36.1.2.1.1

The information regarding a single Control Unit.

bscCUAddressINTEGERnot-accessible
.1.3.6.1.4.1.9.9.36.1.2.1.1.1

This value is the poll address of the BSC Control Unit. This address must be unique within a BSTUN Group.

bscCUStateINTEGERread-only
.1.3.6.1.4.1.9.9.36.1.2.1.1.2

State of the BSC Control Unit; when active this indicates that the remote Control Unit is polling or responding to polls.

bscCUBytesSentCounter32read-only
.1.3.6.1.4.1.9.9.36.1.2.1.1.3

Count of sent bytes (octets). Includes all control characters.

bscCUBytesReceivedCounter32read-only
.1.3.6.1.4.1.9.9.36.1.2.1.1.4

Count of received bytes (octets). Includes all control characters.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→