CISCO-BRIDGE-DOMAIN-MIB
The CISCO-BRIDGE-DOMAIN-MIB monitors and manages Cisco IOS XR Ethernet Virtual Circuit (EVC) configurations, specifically tracking Bridge Domain IDs, associated service instances, and interface mappings to define Layer 2 broadcast domains. It provides visibility into heterogeneous interface bindings (Ethernet, ATM, Frame Relay) and enforces local VLAN scope, enabling the verification of up to 16,000 broadcast domains and their associated MAC address forwarding tables independent of global VLAN constraints.
Imported Objects
Objects
21 total| Object Name |
|---|
ciscoBridgeDomainMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.642 |
ciscoBdMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.642.0 |
ciscoBdNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.642.0.0 |
ciscoBdMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.642.1 |
cbdSystemInfo OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.642.1.1 |
cbdMembersConfiguredro Unsigned32 .1.3.6.1.4.1.9.9.642.1.1.1 |
cbdMemberInfo OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.642.1.2 |
cbdMemberInfoTable SEQUENCE OF CbdMemberInfoEntry .1.3.6.1.4.1.9.9.642.1.2.1 |
cbdMemberInfoEntry CbdMemberInfoEntry .1.3.6.1.4.1.9.9.642.1.2.1.1 |
cbdSIIndex Unsigned32 (1..4294967295 ) .1.3.6.1.4.1.9.9.642.1.2.1.1.1 |
cbdMemberTyperw CbdType .1.3.6.1.4.1.9.9.642.1.2.1.1.2 |
cbdMemberOperStatero Enumeration .1.3.6.1.4.1.9.9.642.1.2.1.1.3 |
cbdMemberAdminStaterw Enumeration .1.3.6.1.4.1.9.9.642.1.2.1.1.4 |
cbdMemberSplitHorizonrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.642.1.2.1.1.5 |
cbdMemberSplitHorizonNumrw Unsigned32 (0..65535 ) .1.3.6.1.4.1.9.9.642.1.2.1.1.6 |
cbdMemberStorageTyperw StorageType (SNMPv2-TC) .1.3.6.1.4.1.9.9.642.1.2.1.1.7 |
cbdMemberStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.642.1.2.1.1.8 |
cbdMembercMacrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.642.1.2.1.1.9 |
ciscoBdMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.642.2 |
ciscoBdMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.642.2.1 |
ciscoBdMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.642.2.2 |
CISCO-BRIDGE-DOMAIN-MIB Technical Reference Overview
The CISCO-BRIDGE-DOMAIN-MIB SNMP MIB module published by Cisco defines 21 managed OID objects, including 10 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.642. Key tabular structures include cbdMemberInfoTable.
Key OID Definitions in CISCO-BRIDGE-DOMAIN-MIB
.1.3.6.1.4.1.9.9.642A bridge domain is one of the means by which it is possible to define a broadcast domain on a bridging device. It is an alternative to 802.1D bridge-groups and to 802.1Q VLAN bridging. Bridge domain is the service specification, and specifies the broadcast domain number on which this frame of this particular service instance must be made available on. The physical and virtual interfaces that can comprise a bridge domain are heterogeneous in nature comprising Ethernet service instances, WAN Virtual Circuit for ATM or Frame Relay and VFIs. However, the frame encapsulations for all interface types are essentially Ethernet. Without bridge-domains, VLANs would have to be globally unique per device and one would only be restricted to the theoretical maximum of 4095 VLANs for single tagged traffic. However with the introduction of bridge-domains, one can associate a service instance with a bridge-domain and all service instances in the same bridge-domain form a broadcast domain. Bridge-domain ID determines the broadcast domain and the VLAN id is merely used to match and map traffic. With bridge domain feature configured VLAN IDs would be unique per interface only and not globally. Thus bridge domains make VLAN ids have only local significance per port Differences between Bridge Domains and 802.1AD Bridges: ======================================================= 1. Scope of the VLAN technology which uses 802.1 AD is global to the box. But in case of Bridge domain, the scope of vlan is local to interface 2. Switchport 802.1AD restricts the number of broadcast domain on a box to 4095. However, with Bridge domains, we can have up to 16k broadcast domain. 3. Under a single Bridge domain service instance, there can be flexible service mapping criterion.(i.e match based on outer vlan, outer cos, inner vlan, inner cos and payload ethertype). Whereas in case of switch port 802.1AD/dot1q this is not supported. Similarities between Bridge Domains and 802.1AD Bridges: ======================================================= 1. Both use the same MAC address lookup for forwarding. 2. Both work with protocols like STP, DTP etc. 3. Both of them classify 'ports' in a system into Bridges/Bridge Domains. Ethernet service instance is the instantiation of an Ethernet virtual circuit on a given port on a given router. In other words, an Ethernet service instance is an object that holds information about the layer 2 service that is being offered on a given port of a given router as part of a given Ethernet virtual circuit. Bridge domains feature is currently supported on ethernet service instances only and can be later extented to other interfaces like ATM and Frame Relay. This MIB helps the network management personnel to find out the details of various broadcast domains configured in the network. Definition of terms and acronyms: ATM: Asynchronous Transfer mode BD: Bridge Domain C-mac: Customer MAC EVC: Ethernet Virtual Circuit FR: Frame Relay SH: Split Horizon VFI: Virtual Forwarding Instance VLAN: Virtual Local Area Network WAN: Wide Area Network
.1.3.6.1.4.1.9.9.642.1.2.1This table provides the bridge domain member attributes of the members currently configured for each bridge domain.
.1.3.6.1.4.1.9.9.642.1.1.1This object indicates the number of bridge domain members configured on this bridge domain.
.1.3.6.1.4.1.9.9.642.1.2.1.1A conceptual row in cbdMemberInfoTable. This is indexed by ifIndex and cbdSIIndex. Each row is created when a bridge domain member is configured under a service instance.
.1.3.6.1.4.1.9.9.642.1.2.1.1.1This object indicates an arbitary index that uniquely identifies the Service Instance to which this bridge domain member belongs to.
.1.3.6.1.4.1.9.9.642.1.2.1.1.2This object identifies the type of the bridge domain member like ATM VC, Frame Relay VC, or Ethernet service.
.1.3.6.1.4.1.9.9.642.1.2.1.1.3This object indicates the operational state of the bridge domain Member. Operational state of the Bridge domain member is same as the operational state of the underlying service instance. Bridge domain members are configured under service instances and multiple service instances can be attached to a single physical interface defining various kinds of services. Bridge domain members have many to one relationship with interface Indexes. When ifOperStatus of the underlying interface is down, the state of cbdMemberOperState should be down. When ifOperStatus of the underlying interface is up, cbdMemberOperState can be either up or down based on the state of underlying service instance. 'unknown': the bridge domain member is an unknown state. 'up': the bridge domain member is fully operational and able to bridge the traffic. This means that both the physical interface and the underlying service instance are administratively up. 'down': the Bridge Domain member is down and not capable of bridging. This state means either the underlying service instance is down or the interface is down.
.1.3.6.1.4.1.9.9.642.1.2.1.1.4This object indicates the administrative state of the bridge domain Member. Admin state of the Bridge domain member is same as the admin state of the underlying service instance. Bridge domain members are configured under service instances and multiple service instances can be attached to a single physical interface defining various kinds of services. Bridge Domain members have many to one relationship with interface Indexes. When ifAdminStatus of the unerlying interface is down the state of cbdMemberAdminState should be down. When ifOperStatus of the underlying interface is up cbdMemberAdminState can be either up or down based on the state of underlying service instance. 'unknown': the bridge domain member is in unknown administrative state. 'up': the Bridge Domain member is administratively up. This means that both the physical interface and the underlying service instance are administratively up. 'admindown': the Bridge Domain member is down as it is administratively configured to be down and is not capable of bridging. This means that either the underlying service instance is configured as administratively down or the physical interface is configured as administratively down.
.1.3.6.1.4.1.9.9.642.1.2.1.1.5This object indicates whether split horizon is configured on this bridge domain member.
.1.3.6.1.4.1.9.9.642.1.2.1.1.6This object indicates the split horizon number if configured on the bridge domain member. Split horizon is used to avoid sending traffic between interfaces. Frames are not forwarded to the members belonging to the same split horizon group.
.1.3.6.1.4.1.9.9.642.1.2.1.1.7This object specifies the storage type of this conceptual row. This object can only have a value 'nonVolatile'. Other values are not applicable for this conceptual row and are not supported.
.1.3.6.1.4.1.9.9.642.1.2.1.1.8This object enables the SNMP agent to create, modify, and delete rows in the cbdMemberInfoTable.
.1.3.6.1.4.1.9.9.642.1.2.1.1.9This object indicates if cmac is configured on this bridge domain member. Cmac denotes if this bridge domain is configured as a customer domain.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.