CISCO-ATM-IF-PHYS-MIB
The CISCO-ATM-IF-PHYS-MIB provides managed objects to monitor the physical layer status and operational state of Cisco ATM interfaces, specifically DS3, E3, DS1, E1, and SONET circuits. It enables the tracking of interface availability, signal integrity, and physical link conditions for high-speed digital transmission paths.
Imported Objects
Objects
41 total| Object Name |
|---|
ciscoAtmIfPhysMIB OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45 |
SNMPv2-SMI-v1 Unknown .1.3.6.1.4.1.9.9.45 |
ciscoAtmIfPhysMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.1 |
ciscoAtmIfPhysTable SEQUENCE OF CiscoAtmIfPhysEntry .1.3.6.1.4.1.9.9.45.1.1 |
ciscoAtmIfPhysEntry CiscoAtmIfPhysEntry .1.3.6.1.4.1.9.9.45.1.1.1 |
ciscoAtmIfPhysStatusro Enumeration .1.3.6.1.4.1.9.9.45.1.1.1.1 |
ciscoAtmIfPhysSectionParityErrorsro Counter32 .1.3.6.1.4.1.9.9.45.1.1.1.2 |
ciscoAtmIfPhysLineParityErrorsro Counter32 .1.3.6.1.4.1.9.9.45.1.1.1.3 |
ciscoAtmIfPhysPathParityErrorsro Counter32 .1.3.6.1.4.1.9.9.45.1.1.1.4 |
ciscoAtmIfPhysLcvErrorsro Counter32 .1.3.6.1.4.1.9.9.45.1.1.1.5 |
ciscoAtmIfPhysCBitParityErrorsro Counter32 .1.3.6.1.4.1.9.9.45.1.1.1.6 |
ciscoAtmIfPhysPBitParityErrorsro Counter32 .1.3.6.1.4.1.9.9.45.1.1.1.7 |
ciscoAtmIfPhysPlcpBipViolationsro Counter32 .1.3.6.1.4.1.9.9.45.1.1.1.8 |
ciscoAtmIfPhysLineFebeErrorsro Counter32 .1.3.6.1.4.1.9.9.45.1.1.1.9 |
ciscoAtmIfPhysPathFebeErrorsro Counter32 .1.3.6.1.4.1.9.9.45.1.1.1.10 |
ciscoAtmIfPhysCellPayloadScramblingrw Enumeration .1.3.6.1.4.1.9.9.45.1.1.1.11 |
ciscoAtmIfPhysStsStreamScramblingrw Enumeration .1.3.6.1.4.1.9.9.45.1.1.1.12 |
ciscoAtmIfPhysFramingModerw Enumeration .1.3.6.1.4.1.9.9.45.1.1.1.13 |
ciscoAtmIfPhysLoopbackConfigrw Enumeration .1.3.6.1.4.1.9.9.45.1.1.1.14 |
ciscoAtmIfPhysLineBuildOutrw Enumeration .1.3.6.1.4.1.9.9.45.1.1.1.15 |
ciscoAtmIfPhysTransmitClockSourcerw Enumeration .1.3.6.1.4.1.9.9.45.1.1.1.16 |
ciscoAtmIfPhysClockSourcePriorityrw Enumeration .1.3.6.1.4.1.9.9.45.1.1.1.17 |
ciscoAtmIfPhysClockSourceStatusro Enumeration .1.3.6.1.4.1.9.9.45.1.1.1.18 |
ciscoAtmIfPhysDS1BitErrorsro Counter32 .1.3.6.1.4.1.9.9.45.1.1.1.19 |
ciscoAtmIfPhysE1CrcErrorsro Counter32 .1.3.6.1.4.1.9.9.45.1.1.1.20 |
ciscoAtmIfPhysLineCoderw Enumeration .1.3.6.1.4.1.9.9.45.1.1.1.21 |
ciscoAtmIfPhysMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3 |
ciscoAtmIfPhysMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.1 |
ciscoAtmIfPhysMIBCompliance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.1.1 |
ciscoAtmIfPhysMIBCompliance2 OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.1.2 |
ciscoAtmIfPhysMIBCompliance3 OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.1.3 |
ciscoAtmIfPhysMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.2 |
ciscoAtmIfPhysMIBCommonGroup OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.2.1 |
ciscoAtmIfPhysMIBSonetGroup OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.2.2 |
ciscoAtmIfPhysMIBDs3E3Group OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.2.3 |
ciscoAtmIfPhysMIBCommonGroup2 OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.2.4 |
ciscoAtmIfPhysMIBSonetGroup2 OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.2.5 |
ciscoAtmIfPhysMIBDs3Group OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.2.6 |
ciscoAtmIfPhysMIBDs1E1Group OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.2.7 |
ciscoAtmIfPhysMIBDs1Group OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.2.8 |
ciscoAtmIfPhysMIBE1Group OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.45.3.2.9 |
CISCO-ATM-IF-PHYS-MIB Technical Reference Overview
The CISCO-ATM-IF-PHYS-MIB SNMP MIB module published by Cisco defines 41 managed OID objects, including 22 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events. Key tabular structures include ciscoAtmIfPhysTable.
Key OID Definitions in CISCO-ATM-IF-PHYS-MIB
.1.3.6.1.4.1.9.9.45.1.1A table containing basic status and statistics for the physical layer of ATM interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1Basic status and statistics for the physical layer of an ATM interface.
.1.3.6.1.4.1.9.9.45.1.1.1.1The status of the physical interface. The value of this object is only valid when the interface's ifAdminStatus has the value 'up'. Note that some of the enumerated values are specific to a particular physical layer.
.1.3.6.1.4.1.9.9.45.1.1.1.2The number of B1 (BIP) errors on the physical interface. This object is only present for SONET interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.3The number of B2 (BIP) errors on the physical interface. This object is only present for SONET interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.4The number of B3 (BIP) errors on the physical interface. This object is only present for SONET interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.5The number of Line Code Violation errors on the physical interface. This object is only present for DS3/E3/DS1/E1 interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.6The number of C-bit parity violations on the physical interface. This object is only present for DS3 interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.7The number of P-bit parity violations or E3 G.832 BIP-8 errors on the physical interface. This object is present only for DS3/E3 interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.8The number of PLCP BIP violations on the physical interface. This object is only present for DS3/E3/DS1/E1 interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.9The number of Z2 (Line FEBE) errors on the physical interface. This object is only present for SONET interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.10The number of G1 (Path FEBE) errors on the physical interface. This object is only present for SONET interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.11The status of whether cell payload scrambling is enabled or disabled on the physical interface.
.1.3.6.1.4.1.9.9.45.1.1.1.12The status of whether STS-stream scrambling is enabled or disabled on the physical interface.
.1.3.6.1.4.1.9.9.45.1.1.1.13The framing format present on the physical interface. 'sonet' indicates sts-3c or sts-12c format and applies only to OC-3 and OC-12 type interfaces, respectively. 'sdh' indicates stm1 or stm4 format and applies only to OC-3 and OC-12 type interfaces, respectively. 'ds3m23adm' indicates M23 ADM mode and applies only to DS3 type interfaces. 'ds3m23plcp' indicates M23 PLCP mode and applies only to DS3 type interfaces. 'ds3cbitadm' indicates C-BIT ADM mode and applies only to DS3 type interfaces. 'ds3cbitplcp' indicates C-BIT PLCP mode and applies only to DS3 type interfaces. 'e3g832adm' indicates G.832 ADM mode and applies only to E3 type interfaces. 'e3g751adm' indicates G.751 ADM mode and applies only to E3 type interfaces. 'e3g751plcp' indicates G.751 PLCP mode and applies only to E3 type interfaces. 'ds1sfadm' indicates DS1 SF ADM mode and applies only to DS1 type interfaces. 'ds1esfadm' indicates DS1 ESF ADM mode and applies only to DS1 type interfaces. 'ds1sfplcp' indicates DS1 SF PLCP mode and applies only to DS1 type interfaces. 'ds1esfplcp' indicates DS1 ESF PLCP mode and applies only to DS1 type interfaces. 'e1adm' indicates E1 ADM mode and applies only to E1 type interfaces. 'e1plcp' indicates E1 PLCP mode and applies only to E1 type interfaces. 'e1crcadm' indicates E1 CRC-4 ADM mode and applies only to E1 type interfaces. 'e1crcplcp' indicates E1 CRC-4 PLCP mode and applies only to E1 type interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.14The loopback configured on the physical interface: 'noLoop' indicates no loopback is present. 'diagnosticLoop' indicates transmit data stream is looped to the receive direction. 'lineLoop' indicates receive data stream is looped to the transmit direction. 'otherLoop' indicates loopbacks that are not defined here.
.1.3.6.1.4.1.9.9.45.1.1.1.15The line buildout configured on the transmit signal: 'e3AllCables' applies to all cables of E3 physical interfaces. 'ds3CablesUnder225' applies to cables under 225 feet of DS3 physical interfaces. 'ds3CablesOver225' applies to cables over 225 feet of DS3 physical interfaces. 'ds1Cables0To110' applies to cables 0 to 110 feet of DS1 physical interfaces. 'ds1Cables110To220' applies to cables 110 to 220 feet of DS1 physical interfaces. 'ds1Cables220To330' applies to cables 220 to 330 feet of DS1 physical interfaces. 'ds1Cables330To440' applies to cables 330 to 440 feet of DS1 physical interfaces. 'ds1Cables440To550' applies to cables 440 to 550 feet of DS1 physical interfaces. 'ds1Cables550To660' applies to cables 550 to 660 feet of DS1 physical interfaces. 'ds1CablesOver600' applies to cables over 600 feet of DS1 physical interfaces. 'e1AllCables' applies to all cables of E1 physical interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.16The source of the tranmit clock: 'loopTiming' indicates that the recovered receive clock is used as the transmit clock. 'freeRunning' indicates that a local clock source is used. 'networkDerived' indicates that recovered receive clock from another interface is used as the transmit clock source.
.1.3.6.1.4.1.9.9.45.1.1.1.17The priority of this interface if configured as a network clock source. 'notConfigured' indicates this is not configured as a network clock source.
.1.3.6.1.4.1.9.9.45.1.1.1.18The network clock source status of this interface: 'notSelected' indicates this is not selected as the network clock source. 'selected' indicates this is selected as the network clock source.
.1.3.6.1.4.1.9.9.45.1.1.1.19The number of bit errors (CRC-6 error in ESF mode and framing bit error in SF mode) on the physical interface. This object is only present for DS1 interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.20The number of CRC errors (in CRC-4 mode) on the physical interface. This object is only present for E1 interfaces.
.1.3.6.1.4.1.9.9.45.1.1.1.21The line coding present on the physical interface This object is only present for DS1/E1 interfaces. 'ami' indicates alternate mark inversion (AMI) line code on the DS1/E1 interface. 'b8zs' indicates B8ZS line code on the physical interface and applies only to DS1 interfaces. 'hdb3' indicates HDB3 line code on the physical interface and applies only to E1 interfaces.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.