The CISCO-ATM-DUAL-PHY-MIB manages redundant physical ATM interfaces on Cisco Catalyst 5000 line cards, exposing dual PHY entities as distinct `ifIndex` entries within the standard `ifTable` to monitor active status, administrative state, and operational state for failover redundancy.

Initial version of this MIB module. Phy definition Throughout this document phy is used as an abbreviation for Physical Interface. In particular it refers to a physical ATM jack on a Catalyst 5000 ATM card. This card can be fitted with either one or two physical jacks, only one of which may be active at any given moment. The second phy serves as a redundant connector to the ATM backbone. Note, however, that for logistical reasons, each phy has a separate ifIndex. Support of the phy by ifTable The dual phy entity on the c5K ATM line card is managed using the ifTable. Specific interpretations of ifTable for the dual phy entity are as follows. Object Use for dual phy entity ====== ======================= ifIndex Each phy entity is represented by an ifEntry. ifDescr Description of the phy entity. ifType The value for the phy entity is other(1). ifSpeed See [1]. ifPhysAddress An octet string of zero length, per [1]. ifAdminStatus See [1]. ifOperStatus See [1]. In addition, note that a phy can be in the up state but still not be the active phy. However, the active phy will always be up. ifLastChange See [1]. ifName See [1]. ifLinkUpDownTrapEnable disabled(2). ifHighSpeed See [1]. ifConnectorPresent true(1). References [1] McCloghrie, K. and F. Kastenholz, Evolution of the Interfaces Group of MIB-II, RFC 1573, Hughes LAN Systems, FTP Software, January 1994.
Main OID:
ciscoAtmDualPhyMIB.1.3.6.1.4.1.9.9.60
23
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

23 total
Object Name
ciscoAtmDualPhyMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.60
ciscoAtmDualPhyMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.60.1
cadpStatistics
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.60.1.1
cadpStatTable
SEQUENCE OF CadpStatEntry
.1.3.6.1.4.1.9.9.60.1.1.1
cadpStatEntry
CadpStatEntry
.1.3.6.1.4.1.9.9.60.1.1.1.1
cadpStatLossOfSignalro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.60.1.1.1.1.1
cadpStatFarEndReceiveFailurero
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.60.1.1.1.1.2
cadpStatActivero
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.60.1.1.1.1.5
cadpStatSectionBIP8Errorsro
Counter32
.1.3.6.1.4.1.9.9.60.1.1.1.1.6
cadpStatLineBIP824Errorsro
Counter32
.1.3.6.1.4.1.9.9.60.1.1.1.1.7
cadpStatLineFEBErrorsro
Counter32
.1.3.6.1.4.1.9.9.60.1.1.1.1.8
cadpStatPathBIP8Errorsro
Counter32
.1.3.6.1.4.1.9.9.60.1.1.1.1.9
cadpStatPathFEBErrorsro
Counter32
.1.3.6.1.4.1.9.9.60.1.1.1.1.10
cadpStatCorrectableHCSErrorsro
Counter32
.1.3.6.1.4.1.9.9.60.1.1.1.1.11
cadpStatUncorrectableHCSErrorsro
Counter32
.1.3.6.1.4.1.9.9.60.1.1.1.1.12
cadpStatOperActivePhyro
InterfaceIndexOrZero (CISCO-TC)
.1.3.6.1.4.1.9.9.60.1.1.2
cadpStatAdminActivePhyrw
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.9.60.1.1.3
ciscoAtmDualPhyMIBTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.60.2
ciscoAtmDualPhyMIBTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.60.2.0
ciscoAtmDualPhyChange
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.60.2.0.1
ciscoAtmDualPhyMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.60.3
ciscoAtmDualPhyMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.60.3.1
ciscoAtmDualPhyMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.60.3.2

CISCO-ATM-DUAL-PHY-MIB Technical Reference Overview

The CISCO-ATM-DUAL-PHY-MIB SNMP MIB module published by Cisco defines 23 managed OID objects, including 12 scalar/column metrics, 1 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.60. Key tabular structures include cadpStatTable. Monitored SNMP traps/notifications include ciscoAtmDualPhyChange.

Key OID Definitions in CISCO-ATM-DUAL-PHY-MIB

ciscoAtmDualPhyMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.60

Initial version of this MIB module. Phy definition Throughout this document phy is used as an abbreviation for Physical Interface. In particular it refers to a physical ATM jack on a Catalyst 5000 ATM card. This card can be fitted with either one or two physical jacks, only one of which may be active at any given moment. The second phy serves as a redundant connector to the ATM backbone. Note, however, that for logistical reasons, each phy has a separate ifIndex. Support of the phy by ifTable The dual phy entity on the c5K ATM line card is managed using the ifTable. Specific interpretations of ifTable for the dual phy entity are as follows. Object Use for dual phy entity ====== ======================= ifIndex Each phy entity is represented by an ifEntry. ifDescr Description of the phy entity. ifType The value for the phy entity is other(1). ifSpeed See [1]. ifPhysAddress An octet string of zero length, per [1]. ifAdminStatus See [1]. ifOperStatus See [1]. In addition, note that a phy can be in the up state but still not be the active phy. However, the active phy will always be up. ifLastChange See [1]. ifName See [1]. ifLinkUpDownTrapEnable disabled(2). ifHighSpeed See [1]. ifConnectorPresent true(1). References [1] McCloghrie, K. and F. Kastenholz, Evolution of the Interfaces Group of MIB-II, RFC 1573, Hughes LAN Systems, FTP Software, January 1994.

cadpStatTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.60.1.1.1

A table of status information about ATM phy.

ciscoAtmDualPhyChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.60.2.0.1

A ciscoAtmDualPhyChange trap is sent when the active phy changes either because of a failure or because of user intervention (setting cadpStatAdminActivePhy, for example).

cadpStatOperActivePhyInterfaceIndexOrZeroread-only
.1.3.6.1.4.1.9.9.60.1.1.2

Returns the ifIndex of the phy which is currently the active phy. A value of 0 indicates that no phy is currently active.

cadpStatAdminActivePhyInterfaceIndexread-write
.1.3.6.1.4.1.9.9.60.1.1.3

Returns the ifIndex of the phy which is the preferred active phy. A value of 0 indicates that no phy is currently active. Setting this object to a value different from its current value causes the ATM module to make the indicated phy active, and the active phy inactive. Setting this object to its current value has no effect. After performing the phy change, the agent will update all phy information (including cadpStatOperActivePhy) and send a ciscoAtmDualPhyChange trap.

cadpStatEntryCadpStatEntrynot-accessible
.1.3.6.1.4.1.9.9.60.1.1.1.1

An Atm Phy table entry, containing information about a phy on this ATM module.

cadpStatLossOfSignalTruthValueread-only
.1.3.6.1.4.1.9.9.60.1.1.1.1.1

Set to true if the phy is currently experiencing a loss of signal (LOS) from its connected port. Set to false if the phy is not experiencing a loss of signal.

cadpStatFarEndReceiveFailureTruthValueread-only
.1.3.6.1.4.1.9.9.60.1.1.1.1.2

Set to true if the phy is currently experiencing a far end receive failure (FERF) with its connected port. Set to false if the phy is not experiencing a far end receive failure.

cadpStatActiveTruthValueread-only
.1.3.6.1.4.1.9.9.60.1.1.1.1.5

Set to true when this phy is currently the active phy. Set to false when this phy is not the currently active phy.

cadpStatSectionBIP8ErrorsCounter32read-only
.1.3.6.1.4.1.9.9.60.1.1.1.1.6

The Bit Interleaved Parity 8 is an error checking code applied for quick isolation of faults. Each bit in the B octets is set to 1 or 0 as necessary to obtain even parity over the previous frame. The calculated BIP-8 code for frame N is compared with the BIP-8 code extracted from the B1 byte of frame N+1. Differences indicate that a section level bit error has occurred. Count of Section BIP-8 (Bit Interleaved Parity) errors that have been detected on this phy.

cadpStatLineBIP824ErrorsCounter32read-only
.1.3.6.1.4.1.9.9.60.1.1.1.1.7

The Bit Interleaved Parity 8/24 is an error checking code based on even parity. The calculated BIP code for frame N is compared with the BIP-8/24 code extracted from the B2 byte(s) of frame N+1. Any differences indicate that a line layer bit error has occurred. Count of line bit interleaved partiy (BIP-8/24) errors on this phy.

cadpStatLineFEBErrorsCounter32read-only
.1.3.6.1.4.1.9.9.60.1.1.1.1.8

The number of bits (binary 000 to 1000) in the previous BIP-8 that didn't match the even parity check are inserted by the transmitter. The receiver checks for this in the M0/M1 byte of the frame. A non-zero value (legal range is binary 0000 - 1000) indicates a line layer error in the remote end. Any other value is treated as no error. Count of Line Far End Bit Errors (FEBE) on this phy.

cadpStatPathBIP8ErrorsCounter32read-only
.1.3.6.1.4.1.9.9.60.1.1.1.1.9

The Bit Interleaved Parity 8 is an error checking code applied for quick isolation of faults. Each bit in the B octets is set to 1 or 0 as necessary to obtain even parity over the previous frame. The calculated BIP-8 code for frame N is compared with the BIP-8 code extracted from the B3 byte of frame N+1. Differences indicate that a Path level bit error has occurred. Count of Path BIP-8 (Bit Interleaved Parity) errors that have been detected on this phy.

cadpStatPathFEBErrorsCounter32read-only
.1.3.6.1.4.1.9.9.60.1.1.1.1.10

The number of B3 errors in the previous frame inserted by the transmitter. The receiver checks for this in the G1 byte of the frame. A non-zero value (legal range is binary 0000 - 1000) indicates a line layer error in the remote end. Any other value is treated as no error. Count of Path Far End Bit Errors (FEBE) on this phy.

cadpStatCorrectableHCSErrorsCounter32read-only
.1.3.6.1.4.1.9.9.60.1.1.1.1.11

The Header Checksum (HCS) is a CRC-8 calculation over the first 4 octets of the ATM cell header. The received HCS is verified using the polynomial x^8 + x^2 + x + 1. The coset polynomial x^6 + x^4 + x^2 + 1, is added (modulo 2) to the received HCS octet before comparison with the calculated result. Cells with single bit error in the HCS byte are corrected. Cells with more than one bit error in the HCS byte are uncorrectable. Count of incoming cells on this phy with single bit error in the Header Checksum (HCS) byte

cadpStatUncorrectableHCSErrorsCounter32read-only
.1.3.6.1.4.1.9.9.60.1.1.1.1.12

The Header Checksum (HCS) is a CRC-8 calculation over the first 4 octets of the ATM cell header. The received HCS is verified using the polynomial x^8 + x^2 + x + 1. The coset polynomial x^6 + x^4 + x^2 + 1, is added (modulo 2) to the received HCS octet before comparison with the calculated result. Cells with single bit error in the HCS byte are corrected. Cells with more than one bit error in the HCS byte are uncorrectable. Count of uncorrectable Header Checksum (HCS) errors on this phy.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→