CISCO-AAA-CLIENT-MIB
Standard SNMP MIB module defining data structures for CISCO-AAA-CLIENT-MIB.
Imported Objects
Objects
27 total| Object Name |
|---|
ciscoAAAClientMIB OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158 |
CISCO-SMI Unknown .1.3.6.1.4.1.9.9.158 |
cacMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.1 |
cacPriority OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.1.1 |
cacPriorityTable SEQUENCE OF CacPriorityEntry .1.3.6.1.4.1.9.9.158.1.1.1 |
cacPriorityEntry CacPriorityEntry .1.3.6.1.4.1.9.9.158.1.1.1.1 |
cacSession SessionType -- Rsyntax INTEGER { -- telnet(1), -- console(2), -- http(3) -- } .1.3.6.1.4.1.9.9.158.1.1.1.1.1 |
cacAuthen AuthenMethod -- Rsyntax INTEGER { -- tacacs(1), -- radius(2), -- kerberos(3), -- local(4) -- } .1.3.6.1.4.1.9.9.158.1.1.1.1.2 |
cacLoginMode LoginMode -- Rsyntax INTEGER { -- login(1), -- enable(2) -- } .1.3.6.1.4.1.9.9.158.1.1.1.1.3 |
cacEnablerw TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } .1.3.6.1.4.1.9.9.158.1.1.1.1.4 |
cacPriorityNumberro INTEGER .1.3.6.1.4.1.9.9.158.1.1.1.1.5 |
cacPrimaryMethodrw TruthValue -- Rsyntax INTEGER { -- true(1), -- false(2) -- } .1.3.6.1.4.1.9.9.158.1.1.1.1.6 |
cacLoginConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.1.2 |
cacLoginConfigTable SEQUENCE OF CacLoginConfigEntry .1.3.6.1.4.1.9.9.158.1.2.1 |
cacLoginConfigEntry CacLoginConfigEntry .1.3.6.1.4.1.9.9.158.1.2.1.1 |
cacMaxLoginAttemptrw INTEGER(0|3..10) .1.3.6.1.4.1.9.9.158.1.2.1.1.1 |
cacLockoutPeriodrwdeprecated INTEGER(0|30..600) -- Units -- seconds .1.3.6.1.4.1.9.9.158.1.2.1.1.2 |
cacLockoutPeriodExtrw INTEGER(0|30..43200) -- Units -- seconds .1.3.6.1.4.1.9.9.158.1.2.1.1.3 |
cacMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.2 |
cacMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.3 |
cacMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.3.1 |
cacMIBCompliance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.3.1.1 |
cacMIBCompliance2 OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.3.1.2 |
cacMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.3.2 |
cacPriorityGroup OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.3.2.1 |
cacLoginConfigGroup OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.3.2.2 |
cacLoginConfigGroupRev1 OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.158.3.2.3 |
CISCO-AAA-CLIENT-MIB Technical Reference Overview
The CISCO-AAA-CLIENT-MIB SNMP MIB module published by Cisco defines 27 managed OID objects, including 10 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events. Key tabular structures include cacPriorityTable, cacLoginConfigTable.
Key OID Definitions in CISCO-AAA-CLIENT-MIB
.1.3.6.1.4.1.9.9.158.1.1.1This table contains entries for AAA authentication methods configured in the system. At startup, agent set up all the entries of the table. All authentication methods will be disabled except local authentication will be enabled for each session type and login mode. Users later can enable/disable a specific authentication method through cacEnable object. The following table describes the startup state of each authentication method and session type in normal login mode and enable login mode. AuthenMethod Console Session Telnet Session Http Session tacacs disabled disabled disabled radius disabled disabled disabled kerberos disabled disabled disabled local enabled(*) enabled(*) enabled(*) (*) denotes primary method.
.1.3.6.1.4.1.9.9.158.1.2.1A table that contains login configuration which is associated with this system.
.1.3.6.1.4.1.9.9.158.1.1.1.1An entry containing the priority number of an authentication method used in a session.
.1.3.6.1.4.1.9.9.158.1.1.1.1.1This is the session type used to connect to the network device.
.1.3.6.1.4.1.9.9.158.1.1.1.1.2This is the authentication method used to authenticate users.
.1.3.6.1.4.1.9.9.158.1.1.1.1.3This is the login mode user used to login to the network device.
.1.3.6.1.4.1.9.9.158.1.1.1.1.4It indicates whether the authentication method denoted by cacAuthen is enabled or not. When this object is true(1), the authentication method denoted by cacAuthen is enabled. When this object is false(2), the authentication method denoted by cacAuthen is disabled. If the value of cacAuthen is local, the value of this object cannot be set to false(2).
.1.3.6.1.4.1.9.9.158.1.1.1.1.5This is the priority number of an authentication method to be used in user authentication for a session. This value is automatically assigned and reflects the relative priority of the authentication method denoted by cacAuthen with respected to already configured authentication methods. It is assigned in the order in which the authentication method is enabled by the user through cacEnable. The higher value has the higher priority. This object is used to determine the fallback order in case the primary authentication method indicated by cacPrimaryMethod failed. If the authentication method denoted by cacAuthen is disabled for the type of session denoted by cacSession, the value of this object is equal to 0.
.1.3.6.1.4.1.9.9.158.1.1.1.1.6It indicates whether the authentication method denoted by cacAuthen is the primary (first one to be tried) method when there are multiple authentication method configured. Setting this object to true(1) will make the authentication method denoted by cacAuthen to be the primary authentication method for the session denoted by cacSession. The previously configured primary method will be changed to false(2). Setting this object to false(2) is not allowed.
.1.3.6.1.4.1.9.9.158.1.2.1.1An entry containing the configuration of the login.
.1.3.6.1.4.1.9.9.158.1.2.1.1.1Indicates the maximum number of login attempts allowed. Setting this variable to 0 will disable the attempt limit checking. If the login session type does not support this attempt limit checking, the value of this object can only be set to 0.
.1.3.6.1.4.1.9.9.158.1.2.1.1.2Indicates the lockout period after the maximum number of login attempt is met. For console, the console input will be frozen during this period. For remote logins, the connection will be closed and any subsequent access from that station will be closed during the lockout time. Setting this variable to 0 will disable the lockout. If the login session type does not support this lockout period, the value of this object can only be set to 0. If the lockout period is greater than the maximum value reportable by this object then this object should report its maximum value (600) and cacLockoutPeriodExt must be used to report the lockout period.
.1.3.6.1.4.1.9.9.158.1.2.1.1.3Specifies the lockout period after the maximum number of login attempt is met. For console, the console input will be frozen during this period. For remote logins, the connection will be closed and any subsequent access from that station will be closed during the lockout time. Setting this variable to 0 will disable the lockout. If the login session type does not support this lockout period, the value of this object can only be set to 0.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.