CIENA-CES-TIME-SYNC-MIB
The CIENA-CES-TIME-SYNC-MIB enables monitoring and management of system timing synchronization parameters and associated notifications on Ciena Carrier Ethernet Service (CES) platforms. It facilitates the tracking of clock synchronization states, timing source selection, and holdover conditions critical for maintaining precise network timing alignment.
Imported Objects
Objects
88 total| Object Name |
|---|
cienaCesTimeSyncMIBThis MIB module defines objects and associated notifications
for the System Timing feature. MODULE-IDENTITY .1.3.6.1.4.1.1271.2.1.28 |
cienaCesTimeSyncMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.28.1 |
cienaCesTimeSyncObjects OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.28.1.1 |
cienaCesSyncAdminStateGlobally enable/disable Syncro CienaGlobalState (CIENA-TC) .1.3.6.1.4.1.1271.2.1.28.1.1.1 |
cienaCesSyncOptionTypeIndication of which set of SSM values being used. Option 1 is
for International standard and Option 2 is for North American.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.2 |
cienaCesSyncRevertiveModeRevertive mode.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.3 |
cienaCesSyncWaitToRestoreTimerUser configured timer for a timing reference source to wait
before transitioning from bad to good clock signal.ro Unsigned32 .1.3.6.1.4.1.1271.2.1.28.1.1.4 |
cienaCesSyncInputProtectionGroupTableA table of protection groups for input timing reference. SEQUENCE OF CienaCesSyncInputProtectionGroupEntry .1.3.6.1.4.1.1271.2.1.28.1.1.5 |
cienaCesSyncInputProtectionGroupEntryAn entry in this table represents information on a protection
group for input timing reference CienaCesSyncInputProtectionGroupEntry .1.3.6.1.4.1.1271.2.1.28.1.1.5.1 |
cienaCesInputPGEntityIdThe unique identifier of this input protection group. Integer32 (1) .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.1 |
cienaCesInputPGEntityNameThe unique name of this input protection group.ro DisplayString .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.2 |
cienaCesInputPGPreferredReferencePreferred timing reference source, configured by users.rodeprecated DisplayString .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.3 |
cienaCesInputPGSelectedReferenceSystem selected timing reference source.ro DisplayString .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.4 |
cienaCesInputPGForcedReferenceSystem was forced to used this timing reference source.ro DisplayString .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.5 |
cienaCesInputPGThresholdQualityLevelSpecified Quality Level threshold for a reference source
being selected.ro SsmStratumLevel .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.6 |
cienaCesInputPGStateConfigured state of this protection group.rodeprecated CienaGlobalState (CIENA-TC) .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.7 |
cienaCesInputPGStateDurationDuration since the system entered current state.ro DisplayString .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.8 |
cienaCesInputPGReferenceSwitchCountThe number of timing reference switching since the system stared up.ro Unsigned32 .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.9 |
cienaCesInputPGOperationalStatusOperational status of this protection group.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.10 |
cienaCesInputPGTimingTypeThe timing domain (freq/phase/tod) that this protection group belongs to.ro SyncTimingType .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.11 |
cienaCesInputPGOperationalQualityLevelOperational Quality Level of the protection group.ro SsmStratumLevel .1.3.6.1.4.1.1271.2.1.28.1.1.5.1.12 |
cienaCesSyncInputProtectionUnitTableA table of protection units for input timing reference. SEQUENCE OF CienaCesSyncInputProtectionUnitEntry .1.3.6.1.4.1.1271.2.1.28.1.1.6 |
cienaCesSyncInputProtectionUnitEntryAn entry in this table represents information on a protection
unit for input timing reference. CienaCesSyncInputProtectionUnitEntry .1.3.6.1.4.1.1271.2.1.28.1.1.6.1 |
cienaCesInputPUEntityIdThe unique identifier of this input protection unit. Integer32 .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.1 |
cienaCesInputPUEntityNameThe unique name of this input protection unit.ro DisplayString .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.2 |
cienaCesInputPUPGEntityNameThe identifier of the input protection group(s) which this input
protection unit belongs to.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.3 |
cienaCesInputPUTimingInterfaceNameThe interface name of this input protection unit.ro DisplayString .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.4 |
cienaCesInputPUTimingInterfaceProtocolThe interface protocol of this input protection unit.ro SyncInterfaceProtocol .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.5 |
cienaCesInputPUUserPriorityThe user configured priority of this input protection unit.ro Unsigned32 .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.6 |
cienaCesInputPUOperationalQLOperational clock quality level of this input protection unit.ro SsmStratumLevel .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.7 |
cienaCesInputPUForcedQLUser configured clock quality level that this input protection unit
is forced to operate at.ro SsmStratumLevel .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.8 |
cienaCesInputPUReceivedQLActual received clock quality level of this input protection unit.ro SsmStratumLevel .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.9 |
cienaCesInputPUSsmEnabledEnable/disable reading of actual received clock quality level for
this input protection unit.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.10 |
cienaCesInputPUOperationalStatusOperational status of this input protection unit.ro SyncRefOperationalStatus .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.11 |
cienaCesInputPUBITSSignalModeBITS Signal Mode, set if BITS signal is used as a protection unit.ro SyncBITSSignalMode .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.12 |
cienaCesInputPUBITSSignalFormatBITS Signal Format, set if BITS signal is used as a protection unit.ro SyncBITSSignalFormat .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.13 |
cienaCesInputPUBITSSignalEncodingBITS Signal encoding, set if BITS signal is used as a protection unit.ro SyncBITSSignalEncoding .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.14 |
cienaCesInputPUUserOverridePriorityThe user configured override-priority of this input protection unit.ro Unsigned32 .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.15 |
cienaCesInputPUPTPEncapTypePTP Encapsulation Type, set if a PTP input is used as a protection unit.ro SyncPTPEncapType .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.16 |
cienaCesInputPUGPSClockModeGPS clock mode, set if a GPS input is used as a protection unit.ro SyncTimingType .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.17 |
cienaCesInputPUGPSFreqClockGPS frequency clock, set if a GPS input is used as a protection unit and the
cienaCesInputPUGPSClockMode is set to frequency.ro SyncGPSFreqClock .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.18 |
cienaCesInputPUBITSSignalSsmLocationBITS Signal Ssm Location, set if BITS signal is used as an input reference.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.6.1.19 |
cienaCesSyncOutputTableA table of output timing references. SEQUENCE OF CienaCesSyncOutputEntry .1.3.6.1.4.1.1271.2.1.28.1.1.7 |
cienaCesSyncOutputEntryAn entry in this table represents information for an output
timing reference. CienaCesSyncOutputEntry .1.3.6.1.4.1.1271.2.1.28.1.1.7.1 |
cienaCesOutputEntityIdThe unique identifier of this output reference entity. Integer32 .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.1 |
cienaCesOutputEntityNameThe unique name of this output reference entity.ro DisplayString .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.2 |
cienaCesOutputTimingInterfaceNameThe interface name of this output reference.ro DisplayString .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.3 |
cienaCesOutputTimingInterfaceProtocolThe interface protocol of this output reference.ro SyncInterfaceProtocol .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.4 |
cienaCesOutputOperationalQLOperational clock quality level of this output reference.ro SsmStratumLevel .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.5 |
cienaCesOutputOperationalStatusOperational status of this output reference.ro SyncRefOperationalStatus .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.6 |
cienaCesOutputBITSSignalModeBITS Signal Mode, set if BITS signal is used as an output reference.ro SyncBITSSignalMode .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.7 |
cienaCesOutputBITSSignalFormatBITS Signal Format, set if BITS signal is used as an output reference.ro SyncBITSSignalFormat .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.8 |
cienaCesOutputBITSSignalEncodingBITS Signal encoding, set if BITS signal is used as an output reference.ro SyncBITSSignalEncoding .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.9 |
cienaCesOutputBITSSignalLineBuildoutBITS Signal Line Buildout, set if BITS signal is used as an output reference.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.10 |
cienaCesOutputBITSSignalSsmLocationBITS Signal Ssm Location, set if BITS signal is used as an output reference.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.11 |
cienaCesOutputGPSClockModeGPS clock mode, set if a GPS signal is used as an output reference.ro SyncTimingType .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.12 |
cienaCesOutputGPSFreqClockGPS frequency clock, set if a GPS signal is used as an output reference and the
cienaCesOutputGPSClockMode is set to frequency.ro SyncGPSFreqClock .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.13 |
cienaCesOutputPTPEncapTypePTP Encapsulation Type, set if a PTP output is used as an output reference.ro SyncPTPEncapType .1.3.6.1.4.1.1271.2.1.28.1.1.7.1.14 |
cienaCesSyncPTPConfig OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.28.1.1.8 |
cienaCesSyncPTPGlobalConfig OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.28.1.1.8.1 |
cienaCesSyncPTPAddrModePTP Address Mode.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.8.1.1 |
cienaCesSyncPTPTagPriorityPTP tag priorityro Unsigned32 .1.3.6.1.4.1.1271.2.1.28.1.1.8.1.2 |
cienaCesSyncPTPProtocolVersionPTP Protocol Version.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.8.1.3 |
cienaCesSyncPTPProfileVersionPTP Profile Version.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.8.1.4 |
cienaCesSyncPTPProfileIdentifierPTP profile identifier address.ro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.1271.2.1.28.1.1.8.1.5 |
cienaCesSyncPTPDomainNumberPTP domain number.ro Unsigned32 .1.3.6.1.4.1.1271.2.1.28.1.1.8.1.6 |
cienaCesSyncPTPClockTypePTP Clock Type.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.8.1.7 |
cienaCesSyncPTPClockIDPTP clock identifier.ro DisplayString .1.3.6.1.4.1.1271.2.1.28.1.1.8.1.8 |
cienaCesSyncPTPDscpPTP DSCP.ro Unsigned32 .1.3.6.1.4.1.1271.2.1.28.1.1.8.1.9 |
cienaCesSyncPTPInputConfig OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.28.1.1.8.2 |
cienaCesSyncPTPInputUnicastReqDurationPTP input unicast request duration in seconds.ro Unsigned32 .1.3.6.1.4.1.1271.2.1.28.1.1.8.2.1 |
cienaCesSyncPTPInputAnnounceRxLossNumPTP input announce Rx loss num (announce intervals).ro Unsigned32 .1.3.6.1.4.1.1271.2.1.28.1.1.8.2.2 |
cienaCesSyncPTPInputAnnounceTxRateReqPTP input announce Tx rate request (pps).ro SyncPTPRatePps .1.3.6.1.4.1.1271.2.1.28.1.1.8.2.3 |
cienaCesSyncPTPInputSyncTxRateReqPTP input sync Tx rate request (pps).ro SyncPTPRatePps .1.3.6.1.4.1.1271.2.1.28.1.1.8.2.4 |
cienaCesSyncPTPInputDelayReqTxRatePTP input delay request Tx rate (pps).ro SyncPTPRatePps .1.3.6.1.4.1.1271.2.1.28.1.1.8.2.5 |
cienaCesSyncPTPOutputConfig OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.28.1.1.8.3 |
cienaCesSyncPTPOutputMaxSlaveSessionsMaximum number of allowed PTP slave sessions for PTP outputs.ro Unsigned32 .1.3.6.1.4.1.1271.2.1.28.1.1.8.3.1 |
cienaCesSyncPTPOutputTimestampModePTP timestamp mode.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.8.3.2 |
cienaCesSyncGPSConfig OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.28.1.1.9 |
cienaCesSyncGPSOutputConfig OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.1.28.1.1.9.1 |
cienaCesSyncGPSOutput1ppsPulseWidthThe 1pps pulse width, in microseconds, for GPS output references (applicable to phase).ro Unsigned32 .1.3.6.1.4.1.1271.2.1.28.1.1.9.1.1 |
cienaCesSyncHoldoverIntervalUser configured interval after which holdover quality level changes.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.10 |
cienaCesSyncModuleSlotClockStatusLock status of module slot.ro Enumeration .1.3.6.1.4.1.1271.2.1.28.1.1.11 |
cienaCesTimeSyncMIBNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.2.28 |
cienaCesTimeSyncMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.1271.2.2.28.0 |
cienaCesSyncInputPUStateChangeNotificationSent when a configured timing reference transitions states. NOTIFICATION-TYPE .1.3.6.1.4.1.1271.2.2.28.0.1 |
cienaCesSyncInputProtectionGroupStateChangeNotificationSent when a configured protection-group transitions states. NOTIFICATION-TYPE .1.3.6.1.4.1.1271.2.2.28.0.2 |
cienaCesSyncModuleSlotClockStateChangeNotificationSent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x. NOTIFICATION-TYPE .1.3.6.1.4.1.1271.2.2.28.0.3 |
CIENA-CES-TIME-SYNC-MIB Technical Reference Overview
The CIENA-CES-TIME-SYNC-MIB SNMP MIB module published by Ciena defines 88 managed OID objects, including 68 scalar/column metrics, 3 SNMP tables, and 3 trap/notification events anchored at base OID .1.3.6.1.4.1.1271.2.1.28. Key tabular structures include cienaCesSyncInputProtectionGroupTable, cienaCesSyncInputProtectionUnitTable, cienaCesSyncOutputTable. Monitored SNMP traps/notifications include cienaCesSyncInputPUStateChangeNotification, cienaCesSyncInputProtectionGroupStateChangeNotification, cienaCesSyncModuleSlotClockStateChangeNotification.
Key OID Definitions in CIENA-CES-TIME-SYNC-MIB
.1.3.6.1.4.1.1271.2.1.28.1.1.5A table of protection groups for input timing reference.
.1.3.6.1.4.1.1271.2.1.28.1.1.6A table of protection units for input timing reference.
.1.3.6.1.4.1.1271.2.1.28.1.1.7A table of output timing references.
.1.3.6.1.4.1.1271.2.2.28.0.1Sent when a configured timing reference transitions states.
.1.3.6.1.4.1.1271.2.2.28.0.2Sent when a configured protection-group transitions states.
.1.3.6.1.4.1.1271.2.2.28.0.3Sent when a slot other than the primary CTX experiences a timing state change. Only applicable in SAOS 8.x.
.1.3.6.1.4.1.1271.2.1.28.1.1.1Globally enable/disable Sync
.1.3.6.1.4.1.1271.2.1.28.1.1.2Indication of which set of SSM values being used. Option 1 is for International standard and Option 2 is for North American.
.1.3.6.1.4.1.1271.2.1.28.1.1.3Revertive mode.
.1.3.6.1.4.1.1271.2.1.28.1.1.4User configured timer for a timing reference source to wait before transitioning from bad to good clock signal.
.1.3.6.1.4.1.1271.2.1.28.1.1.10User configured interval after which holdover quality level changes.
.1.3.6.1.4.1.1271.2.1.28.1.1.8.1.1PTP Address Mode.
More MIBs from Ciena
Browse all CienaMIBs →The CIENA-CES-PM MIB module enables monitoring of performance statistics and error counters for Carrier Ethernet Service (CES) circuits on Ciena transport equipment. It provides access to specific PM metrics such as cell loss, delay, and jitter measurements required for Service Level Agreement (SLA) compliance verification.
The CIENA-CES-MPLS-MIB enables management of Multiprotocol Label Switching (MPLS) features and associated performance counters on Ciena LEOS-based Carrier Ethernet Services (CES) platforms. It provides visibility into MPLS session states, label bindings, and traffic statistics for provisioning and fault isolation within Ciena's transport network infrastructure.
The CIENA-WS-PM-MIB module enables SNMP-based retrieval of performance monitoring counters and statistics for Ciena Waveserver optical transport equipment. It specifically tracks operational metrics such as optical power levels, bit error rates, and interface utilization to facilitate network health assessment and fault isolation.
The CIENA-CES-CHASSIS-MIB enables monitoring and configuration of physical chassis attributes, including hardware inventory, slot status, and power supply states, on Ciena Carrier Ethernet Service (CES) platforms via SNMP. It facilitates the generation of chassis-specific traps to alert network operations on hardware failures, module insertions, or environmental threshold violations.
The CIENA-CES-DATAPLANE-MIB provides SNMP-based monitoring and management of the data plane interfaces, traffic statistics, and operational status for the Ciena CN5410 Carrier Ethernet Service platform. It enables administrators to track real-time packet throughput, error counters, and interface states to ensure the integrity of Carrier Ethernet services.
The CIENA-CES-CFM-MIB enables the configuration and monitoring of Connectivity Fault Management (CFM) operations on Ciena Carrier Ethernet Services (CES) platforms, specifically tracking maintenance association (MA) states, continuity check (CCM) message counters, and fault notification events for Layer 2 Ethernet service integrity.