CIE1000-SYSUTIL-MIB
This is a private version of SysUtil
Main OID:
cie1000SysutilMib.1.3.6.1.4.1.9.9.832.1.24
78
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
78 total| Object Name |
|---|
cie1000SysutilMibThis is a private version of SysUtil MODULE-IDENTITY .1.3.6.1.4.1.9.9.832.1.24 |
SNMPv2-CONFThis is a private version of SysUtil NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.832.1.24 |
cie1000SysutilMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.1 |
cie1000SysutilCapabilities OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.1.1 |
cie1000SysutilCapabilitiesWarmRebootSupportedIndicate if warm restart is supported or not. true means it is
supported. false means it is not supported.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.24.1.1.1 |
cie1000SysutilCapabilitiesPostSupportedIndicate if POST(Power On Self Test) is supported or not. true(1) means
it is supported. false(2) means it is not supported.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.24.1.1.2 |
cie1000SysutilCapabilitiesZtpSupportedIndicate if ZTP(Zero Touch Provisioning) is supported or not. true(1)
means it is supported. false(2) means it is not supported.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.24.1.1.3 |
cie1000SysutilCapabilitiesStackFwChkSupportedIndicate if stack firmware version check is supported or not. true(1)
means it is supported. false(2) means it is not supported.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.24.1.1.4 |
cie1000SysutilConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.1.2 |
cie1000SysutilConfigSystemInfo OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.1.2.1 |
cie1000SysutilConfigSystemInfoHostnameHostnamerw CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.2.1.1 |
cie1000SysutilConfigSystemInfoContactContact name.rw CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.2.1.2 |
cie1000SysutilConfigSystemInfoLocationLocation.rw CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.2.1.3 |
cie1000SysutilConfigSystemTime OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.1.2.2 |
cie1000SysutilConfigSystemTimeSystemCurTimeCurrent system timerw CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.2.2.1 |
cie1000SysutilConfigSystemTimeSystemCurTimeFormatFormat for setting up current system timerw CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.2.2.2 |
cie1000SysutilConfigTemperatureMonitorTableTable of temperature monitor config. SEQUENCE OF CIE1000SysutilConfigTemperatureMonitorEntry .1.3.6.1.4.1.9.9.832.1.24.1.2.3 |
cie1000SysutilConfigTemperatureMonitorEntryEach row set the sensor config. CIE1000SysutilConfigTemperatureMonitorEntry .1.3.6.1.4.1.9.9.832.1.24.1.2.3.1 |
cie1000SysutilConfigTemperatureMonitorSensorIdThe identification of sensor for tempeature monitor.ro CIE1000SysutilTemperatureMonitorSensorType .1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.1 |
cie1000SysutilConfigTemperatureMonitorLowThresholdThe low threshold of temperature monior.rw Integer32 (-40..125) .1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.2 |
cie1000SysutilConfigTemperatureMonitorHighThresholdThe high threshold of temperature monior.rw Integer32 (-40..125) .1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.3 |
cie1000SysutilConfigTemperatureMonitorCriticalThresholdThe critical threshold of temperature monior.rw Integer32 .1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.4 |
cie1000SysutilConfigTemperatureMonitorHysteresisThe value of hysteresis for temperature check.rw Integer32 .1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.5 |
cie1000SysutilStatus OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.1.3 |
cie1000SysutilStatusCpuLoad OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.1.3.1 |
cie1000SysutilStatusCpuLoadAverage100msecAverage CPU load (%) in 100 milli-seconds.ro Unsigned32 .1.3.6.1.4.1.9.9.832.1.24.1.3.1.1 |
cie1000SysutilStatusCpuLoadAverage1secAverage CPU load (%) in 1 second.ro Unsigned32 .1.3.6.1.4.1.9.9.832.1.24.1.3.1.2 |
cie1000SysutilStatusCpuLoadAverage10secAverage CPU load (%) in 10 seconds.ro Unsigned32 .1.3.6.1.4.1.9.9.832.1.24.1.3.1.3 |
cie1000SysutilStatusPowerSupplyTableTable of power supply status. SEQUENCE OF CIE1000SysutilStatusPowerSupplyEntry .1.3.6.1.4.1.9.9.832.1.24.1.3.2 |
cie1000SysutilStatusPowerSupplyEntryEach row contains the power supply status. CIE1000SysutilStatusPowerSupplyEntry .1.3.6.1.4.1.9.9.832.1.24.1.3.2.1 |
cie1000SysutilStatusPowerSupplySwitchIdThe identification of switch.ro Integer32 .1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.1 |
cie1000SysutilStatusPowerSupplyPsuIdThe identification of power supply.ro Integer32 .1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.2 |
cie1000SysutilStatusPowerSupplyStateThe state of power supply.ro CIE1000SysutilPowerSupplyStateType .1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.3 |
cie1000SysutilStatusPowerSupplyDescriptionThe description of power supply.ro CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.4 |
cie1000SysutilStatusSystemLedTableTable of system LED status. SEQUENCE OF CIE1000SysutilStatusSystemLedEntry .1.3.6.1.4.1.9.9.832.1.24.1.3.3 |
cie1000SysutilStatusSystemLedEntryEach row contains the system LED status. CIE1000SysutilStatusSystemLedEntry .1.3.6.1.4.1.9.9.832.1.24.1.3.3.1 |
cie1000SysutilStatusSystemLedSwitchIdThe identification of switch.ro Integer32 .1.3.6.1.4.1.9.9.832.1.24.1.3.3.1.1 |
cie1000SysutilStatusSystemLedDescriptionThe description of system LED status.ro CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.3.3.1.2 |
cie1000SysutilStatusSystemUptime OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.1.3.4 |
cie1000SysutilStatusSystemUptimeSystemUptimeThe time since the DUT is Up.ro CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.3.4.1 |
cie1000SysutilStatusBoardInfo OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.1.3.5 |
cie1000SysutilStatusBoardInfoBoardMacAddressBoard Mac Addressro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.24.1.3.5.1 |
cie1000SysutilStatusBoardInfoBoardIDBoard IDro Unsigned32 .1.3.6.1.4.1.9.9.832.1.24.1.3.5.2 |
cie1000SysutilStatusBoardInfoBoardSerialBoard IDro CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.3.5.3 |
cie1000SysutilStatusBoardInfoBoardTypeBoard IDro CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.3.5.4 |
cie1000SysutilStatusBoardInfoCipSerialBoard CIP serial numberro CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.3.5.5 |
cie1000SysutilStatusTemperatureMonitorTableTable of temperature monitor status. SEQUENCE OF CIE1000SysutilStatusTemperatureMonitorEntry .1.3.6.1.4.1.9.9.832.1.24.1.3.6 |
cie1000SysutilStatusTemperatureMonitorEntryEach row contains the sensor status. CIE1000SysutilStatusTemperatureMonitorEntry .1.3.6.1.4.1.9.9.832.1.24.1.3.6.1 |
cie1000SysutilStatusTemperatureMonitorSensorIdThe identification of sensor for tempeature monitor.ro CIE1000SysutilTemperatureMonitorSensorType .1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.1 |
cie1000SysutilStatusTemperatureMonitorLowAlarmThe alarm flag of temperature low status.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.2 |
cie1000SysutilStatusTemperatureMonitorHighAlarmThe alarm flag of temperature high status.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.3 |
cie1000SysutilStatusTemperatureMonitorCriticalAlarmThe alarm flag of temperature critical status.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.4 |
cie1000SysutilStatusTemperatureMonitorTemperatureCurrent temperature.ro Integer32 .1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.5 |
cie1000SysutilStatusLedStatus OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.1.3.7 |
cie1000SysutilStatusLedStatusSystemTableThe table is the list of LED nodes. The index is the name of the LED
node SEQUENCE OF CIE1000SysutilStatusLedStatusSystemEntry .1.3.6.1.4.1.9.9.832.1.24.1.3.7.1 |
cie1000SysutilStatusLedStatusSystemEntryAn index is a name e.g. alm CIE1000SysutilStatusLedStatusSystemEntry .1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1 |
cie1000SysutilStatusLedStatusSystemLedIdThe identification of the system LED.ro CIE1000SysutilLedNameIndex .1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.1 |
cie1000SysutilStatusLedStatusSystemLedColorColor of LED. off(0) - The led is off, green(1) - The led is green,
red(2) - The led is red, amber(3) - The led is amber, green_red(4) -
The led is bi-color greed red, green_amber(5) - The led is bi-color
green amber.ro CIE1000SysutilLedColor .1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.2 |
cie1000SysutilStatusLedStatusSystemLedModeType of LED mode.initial(0) Initial state. solid(1) LED is solid
on.off(2) LED is turned off.blinking(3) LED is blinking.alternative(4)
LED is in alternative mode.ro CIE1000SysutilLedMode .1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.3 |
cie1000SysutilStatusLedStatusSystemDescriptionThe description of system LED status.ro CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.4 |
cie1000SysutilStatusLedStatusPortTableThe table is the list of port interface LED nodes. The index is the
port interface SEQUENCE OF CIE1000SysutilStatusLedStatusPortEntry .1.3.6.1.4.1.9.9.832.1.24.1.3.7.2 |
cie1000SysutilStatusLedStatusPortEntryPort interface CIE1000SysutilStatusLedStatusPortEntry .1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1 |
cie1000SysutilStatusLedStatusPortIfIndexLogical interface number.ro CIE1000InterfaceIndex (CIE1000-TC) .1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.1 |
cie1000SysutilStatusLedStatusPortLedColorColor of LED. off(0) - The led is off, green(1) - The led is green,
red(2) - The led is red, amber(3) - The led is amber, green_red(4) -
The led is bi-color greed red, green_amber(5) - The led is bi-color
green amber.ro CIE1000SysutilLedColor .1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.2 |
cie1000SysutilStatusLedStatusPortLedModeType of LED mode.initial(0) Initial state. solid(1) LED is solid
on.off(2) LED is turned off.blinking(3) LED is blinking.alternative(4)
LED is in alternative mode.ro CIE1000SysutilLedMode .1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.3 |
cie1000SysutilStatusLedStatusPortDescriptionThe description of system LED status.ro CIE1000DisplayString .1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.4 |
cie1000SysutilControl OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.1.4 |
cie1000SysutilControlRebootTableThis is a table to reboot a swicth SEQUENCE OF CIE1000SysutilControlRebootEntry .1.3.6.1.4.1.9.9.832.1.24.1.4.1 |
cie1000SysutilControlRebootEntryEach switch has a set of parameters CIE1000SysutilControlRebootEntry .1.3.6.1.4.1.9.9.832.1.24.1.4.1.1 |
cie1000SysutilControlRebootSwitchIdThe identification of switch.ro Integer32 .1.3.6.1.4.1.9.9.832.1.24.1.4.1.1.1 |
cie1000SysutilControlRebootTypeType of reboot. noReboot(0) does not reboot. coldReboot(1) is to do
cold reboot. warmReboot(2) is to do warm reboot, but this is optional.
The OID of vtssSysutilCapabilitiesWarmRebootSupported tells if warm
reboot is supported or not. factoryReset (3) is to remove all
configuration and return to factory settings.rw CIE1000SysutilRebootType .1.3.6.1.4.1.9.9.832.1.24.1.4.1.1.2 |
cie1000SysutilControlSystemLedTableThis is a table to clear the system LED error status SEQUENCE OF CIE1000SysutilControlSystemLedEntry .1.3.6.1.4.1.9.9.832.1.24.1.4.2 |
cie1000SysutilControlSystemLedEntryEach switch has a set of parameters CIE1000SysutilControlSystemLedEntry .1.3.6.1.4.1.9.9.832.1.24.1.4.2.1 |
cie1000SysutilControlSystemLedSwitchIdThe identification of switch.ro Integer32 .1.3.6.1.4.1.9.9.832.1.24.1.4.2.1.1 |
cie1000SysutilControlSystemLedClearStatusType of system LED status clearing.all(0) is used to clear all error
status of the system LED and back to normal indication. fatal(1) is
used to clear fatal error status of the system LED. software(2) is used
to clear generic software error status of the system LED. post(3) is
used to clear POST(Power On Self Test) error status of the system LED.
ztp(4) is used to clear ZTP(Zero Touch Provisioning) error status of
the system LED. stackFwChk(5) is used to clear stack firmware version
check error status of the system LED.rw CIE1000SysutilSystemLedClearType .1.3.6.1.4.1.9.9.832.1.24.1.4.2.1.2 |
cie1000SysutilMibConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.2 |
cie1000SysutilMibCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.2.1 |
cie1000SysutilMibGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.24.2.2 |