CIE1000-PORT-POWER-SAVINGS-MIB
The CIE1000-PORT-POWER-SAVINGS-MIB manages switch port power consumption by monitoring link partner presence and cable length to dynamically reduce port power supply when no active connection exists or when a short cable is detected.
Imported Objects
Objects
24 total| Object Name |
|---|
cie1000PortPowerSavingsMib MODULE-IDENTITY .1.3.6.1.4.1.9.9.832.1.100 |
SNMPv2-CONF NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.832.1.100 |
cie1000PortPowerSavingsMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.100.1 |
cie1000PortPowerSavingsCapabilities OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.100.1.1 |
cie1000PortPowerSavingsCapabilitiesInterfaceTable SEQUENCE OF CIE1000PortPowerSavingsCapabilitiesInterfaceEntry .1.3.6.1.4.1.9.9.832.1.100.1.1.1 |
cie1000PortPowerSavingsCapabilitiesInterfaceEntry CIE1000PortPowerSavingsCapabilitiesInterfaceEntry .1.3.6.1.4.1.9.9.832.1.100.1.1.1.1 |
cie1000PortPowerSavingsCapabilitiesInterfaceIfIndexro CIE1000InterfaceIndex (CIE1000-TC) .1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.1 |
cie1000PortPowerSavingsCapabilitiesInterfaceLinkPartnerro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.2 |
cie1000PortPowerSavingsCapabilitiesInterfaceShortReachro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.3 |
cie1000PortPowerSavingsConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.100.1.2 |
cie1000PortPowerSavingsConfigInterfaceParamTable SEQUENCE OF CIE1000PortPowerSavingsConfigInterfaceParamEntry .1.3.6.1.4.1.9.9.832.1.100.1.2.1 |
cie1000PortPowerSavingsConfigInterfaceParamEntry CIE1000PortPowerSavingsConfigInterfaceParamEntry .1.3.6.1.4.1.9.9.832.1.100.1.2.1.1 |
cie1000PortPowerSavingsConfigInterfaceParamIfIndexro CIE1000InterfaceIndex (CIE1000-TC) .1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.1 |
cie1000PortPowerSavingsConfigInterfaceParamLinkPartnerrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.2 |
cie1000PortPowerSavingsConfigInterfaceParamShortReachrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.3 |
cie1000PortPowerSavingsStatus OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.100.1.3 |
cie1000PortPowerSavingsStatusInterfaceTable SEQUENCE OF CIE1000PortPowerSavingsStatusInterfaceEntry .1.3.6.1.4.1.9.9.832.1.100.1.3.1 |
cie1000PortPowerSavingsStatusInterfaceEntry CIE1000PortPowerSavingsStatusInterfaceEntry .1.3.6.1.4.1.9.9.832.1.100.1.3.1.1 |
cie1000PortPowerSavingsStatusInterfaceIfIndexro CIE1000InterfaceIndex (CIE1000-TC) .1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.1 |
cie1000PortPowerSavingsStatusInterfaceNoLinkPartnerro CIE1000PortPowerSavingsStatusType .1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.2 |
cie1000PortPowerSavingsStatusInterfaceShortCablero CIE1000PortPowerSavingsStatusType .1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.3 |
cie1000PortPowerSavingsMibConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.100.2 |
cie1000PortPowerSavingsMibCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.100.2.1 |
cie1000PortPowerSavingsMibGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.832.1.100.2.2 |
CIE1000-PORT-POWER-SAVINGS-MIB Technical Reference Overview
The CIE1000-PORT-POWER-SAVINGS-MIB SNMP MIB module published by Cisco defines 24 managed OID objects, including 9 scalar/column metrics, 3 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.832.1.100. Key tabular structures include cie1000PortPowerSavingsCapabilitiesInterfaceTable, cie1000PortPowerSavingsConfigInterfaceParamTable, cie1000PortPowerSavingsStatusInterfaceTable. Monitored SNMP traps/notifications include SNMPv2-CONF.
Key OID Definitions in CIE1000-PORT-POWER-SAVINGS-MIB
.1.3.6.1.4.1.9.9.832.1.100This is a private version of Port Power Saving. Port power saving reduces the switch power consumptionby lowering the port power supply when there is no link partner connected to a port as well as when link partner is connected through a short cable.
.1.3.6.1.4.1.9.9.832.1.100.1.1.1This is a table to interface capabilities
.1.3.6.1.4.1.9.9.832.1.100.1.2.1This table provides Port Power Savings configuration for an interface
.1.3.6.1.4.1.9.9.832.1.100.1.3.1This is a table to Port Power Savings interface status
.1.3.6.1.4.1.9.9.832.1.100This is a private version of Port Power Saving. Port power saving reduces the switch power consumptionby lowering the port power supply when there is no link partner connected to a port as well as when link partner is connected through a short cable.
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1Each interface has a set of capability parameters
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.1Logical interface number.
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.2Indicate whether interface is capable for detecting link partner or not. true means interface is capable to detect link partner, false means interface is not capable to detect link partner.
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.3Indicates whether interface is able to determine the cable length connected to partner port. true means interface is capable to determine the cable length, false means interface is not capable to determine the cable length.
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1Each interface has a set of Port Power Savings configurable parameters
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.1Logical interface number.
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.2Save port power if there is no link partner connected to the port. true is to enable port power saving when there is no link partner connected, false is to disable it.
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.3Save port power if port is connected to link partner through short cable. true is to enable port power saving when link partner connected through short cable, false is to disable it.
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1Each interface has a set of status parameters
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.1Logical interface number.
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.2Indicate whether port is saving power due to no link partner connected.
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.3Indicate whether port is saving power due to link partner connected through short cable.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.