The CIE1000-PORT-POWER-SAVINGS-MIB manages switch port power consumption by monitoring link partner presence and cable length to dynamically reduce port power supply when no active connection exists or when a short cable is detected.

This is a private version of Port Power Saving. Port power saving reduces the switch power consumptionby lowering the port power supply when there is no link partner connected to a port as well as when link partner is connected through a short cable.
Main OID:
cie1000PortPowerSavingsMib.1.3.6.1.4.1.9.9.832.1.100
24
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

24 total
Object Name
cie1000PortPowerSavingsMib
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.832.1.100
SNMPv2-CONF
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.832.1.100
cie1000PortPowerSavingsMibObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.832.1.100.1
cie1000PortPowerSavingsCapabilities
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.832.1.100.1.1
cie1000PortPowerSavingsCapabilitiesInterfaceTable
SEQUENCE OF CIE1000PortPowerSavingsCapabilitiesInterfaceEntry
.1.3.6.1.4.1.9.9.832.1.100.1.1.1
cie1000PortPowerSavingsCapabilitiesInterfaceEntry
CIE1000PortPowerSavingsCapabilitiesInterfaceEntry
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1
cie1000PortPowerSavingsCapabilitiesInterfaceIfIndexro
CIE1000InterfaceIndex (CIE1000-TC)
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.1
cie1000PortPowerSavingsCapabilitiesInterfaceLinkPartnerro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.2
cie1000PortPowerSavingsCapabilitiesInterfaceShortReachro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.3
cie1000PortPowerSavingsConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.832.1.100.1.2
cie1000PortPowerSavingsConfigInterfaceParamTable
SEQUENCE OF CIE1000PortPowerSavingsConfigInterfaceParamEntry
.1.3.6.1.4.1.9.9.832.1.100.1.2.1
cie1000PortPowerSavingsConfigInterfaceParamEntry
CIE1000PortPowerSavingsConfigInterfaceParamEntry
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1
cie1000PortPowerSavingsConfigInterfaceParamIfIndexro
CIE1000InterfaceIndex (CIE1000-TC)
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.1
cie1000PortPowerSavingsConfigInterfaceParamLinkPartnerrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.2
cie1000PortPowerSavingsConfigInterfaceParamShortReachrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.3
cie1000PortPowerSavingsStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.832.1.100.1.3
cie1000PortPowerSavingsStatusInterfaceTable
SEQUENCE OF CIE1000PortPowerSavingsStatusInterfaceEntry
.1.3.6.1.4.1.9.9.832.1.100.1.3.1
cie1000PortPowerSavingsStatusInterfaceEntry
CIE1000PortPowerSavingsStatusInterfaceEntry
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1
cie1000PortPowerSavingsStatusInterfaceIfIndexro
CIE1000InterfaceIndex (CIE1000-TC)
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.1
cie1000PortPowerSavingsStatusInterfaceNoLinkPartnerro
CIE1000PortPowerSavingsStatusType
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.2
cie1000PortPowerSavingsStatusInterfaceShortCablero
CIE1000PortPowerSavingsStatusType
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.3
cie1000PortPowerSavingsMibConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.832.1.100.2
cie1000PortPowerSavingsMibCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.832.1.100.2.1
cie1000PortPowerSavingsMibGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.832.1.100.2.2

CIE1000-PORT-POWER-SAVINGS-MIB Technical Reference Overview

The CIE1000-PORT-POWER-SAVINGS-MIB SNMP MIB module published by Cisco defines 24 managed OID objects, including 9 scalar/column metrics, 3 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.832.1.100. Key tabular structures include cie1000PortPowerSavingsCapabilitiesInterfaceTable, cie1000PortPowerSavingsConfigInterfaceParamTable, cie1000PortPowerSavingsStatusInterfaceTable. Monitored SNMP traps/notifications include SNMPv2-CONF.

Key OID Definitions in CIE1000-PORT-POWER-SAVINGS-MIB

cie1000PortPowerSavingsMibMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.832.1.100

This is a private version of Port Power Saving. Port power saving reduces the switch power consumptionby lowering the port power supply when there is no link partner connected to a port as well as when link partner is connected through a short cable.

cie1000PortPowerSavingsCapabilitiesInterfaceTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.832.1.100.1.1.1

This is a table to interface capabilities

cie1000PortPowerSavingsConfigInterfaceParamTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.832.1.100.1.2.1

This table provides Port Power Savings configuration for an interface

cie1000PortPowerSavingsStatusInterfaceTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.832.1.100.1.3.1

This is a table to Port Power Savings interface status

SNMPv2-CONFNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.832.1.100

This is a private version of Port Power Saving. Port power saving reduces the switch power consumptionby lowering the port power supply when there is no link partner connected to a port as well as when link partner is connected through a short cable.

cie1000PortPowerSavingsCapabilitiesInterfaceEntryCIE1000PortPowerSavingsCapabilitiesInterfaceEntrynot-accessible
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1

Each interface has a set of capability parameters

cie1000PortPowerSavingsCapabilitiesInterfaceIfIndexCIE1000InterfaceIndexaccessible-for-notify
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.1

Logical interface number.

cie1000PortPowerSavingsCapabilitiesInterfaceLinkPartnerTruthValueread-only
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.2

Indicate whether interface is capable for detecting link partner or not. true means interface is capable to detect link partner, false means interface is not capable to detect link partner.

cie1000PortPowerSavingsCapabilitiesInterfaceShortReachTruthValueread-only
.1.3.6.1.4.1.9.9.832.1.100.1.1.1.1.3

Indicates whether interface is able to determine the cable length connected to partner port. true means interface is capable to determine the cable length, false means interface is not capable to determine the cable length.

cie1000PortPowerSavingsConfigInterfaceParamEntryCIE1000PortPowerSavingsConfigInterfaceParamEntrynot-accessible
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1

Each interface has a set of Port Power Savings configurable parameters

cie1000PortPowerSavingsConfigInterfaceParamIfIndexCIE1000InterfaceIndexaccessible-for-notify
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.1

Logical interface number.

cie1000PortPowerSavingsConfigInterfaceParamLinkPartnerTruthValueread-write
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.2

Save port power if there is no link partner connected to the port. true is to enable port power saving when there is no link partner connected, false is to disable it.

cie1000PortPowerSavingsConfigInterfaceParamShortReachTruthValueread-write
.1.3.6.1.4.1.9.9.832.1.100.1.2.1.1.3

Save port power if port is connected to link partner through short cable. true is to enable port power saving when link partner connected through short cable, false is to disable it.

cie1000PortPowerSavingsStatusInterfaceEntryCIE1000PortPowerSavingsStatusInterfaceEntrynot-accessible
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1

Each interface has a set of status parameters

cie1000PortPowerSavingsStatusInterfaceIfIndexCIE1000InterfaceIndexaccessible-for-notify
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.1

Logical interface number.

cie1000PortPowerSavingsStatusInterfaceNoLinkPartnerCIE1000PortPowerSavingsStatusTyperead-only
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.2

Indicate whether port is saving power due to no link partner connected.

cie1000PortPowerSavingsStatusInterfaceShortCableCIE1000PortPowerSavingsStatusTyperead-only
.1.3.6.1.4.1.9.9.832.1.100.1.3.1.1.3

Indicate whether port is saving power due to link partner connected through short cable.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→