CERENT-IF-EXT-MIB
The CERENT-IF-EXT-MIB extends the standard interface management capabilities for Cerent Corporation optical transport equipment, specifically providing vendor-specific objects to monitor interface status, error counters, and physical layer parameters beyond the scope of standard MIB-II. This module enables granular visibility into the operational state and performance metrics of Cerent's SONET/SDH and OTN interface cards.
Imported Objects
Objects
12 total| Object Name |
|---|
cerentIfExtMIB MODULE-IDENTITY .1.3.6.1.4.1.3607.1.10.140 |
cerentIfExtMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.3607.2.100 |
cerentIfExtTable SEQUENCE OF CerentIfExtEntry .1.3.6.1.4.1.3607.2.100.10 |
cerentIfExtEntry CerentIfExtEntry .1.3.6.1.4.1.3607.2.100.10.1 |
cerentIfExtPreServiceAlarmSuppressionrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3607.2.100.10.1.10 |
cerentIfExtConfiguredSoakTimerw Integer32 UNITS "minutes" .1.3.6.1.4.1.3607.2.100.10.1.20 |
cerentIfExtCurrentSoakTimero Integer32 UNITS "minutes" .1.3.6.1.4.1.3607.2.100.10.1.30 |
cerentIfExtMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.3607.5.90 |
cerentIfExtMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.3607.5.90.1 |
cerentIfExtMIBCompliance Unknown .1.3.6.1.4.1.3607.5.90.1.1 |
cerentIfExtMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.3607.5.90.2 |
cerentIfExtGroup Unknown .1.3.6.1.4.1.3607.5.90.2.10 |
CERENT-IF-EXT-MIB Technical Reference Overview
The CERENT-IF-EXT-MIB SNMP MIB module published by Cisco defines 12 managed OID objects, including 5 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.3607.1.10.140. Key tabular structures include cerentIfExtTable.
Key OID Definitions in CERENT-IF-EXT-MIB
.1.3.6.1.4.1.3607.1.10.140This module defines objects for managing interfaces.
.1.3.6.1.4.1.3607.2.100.10This table contains one row per interface.
.1.3.6.1.4.1.3607.5.90.2.10The objects for storing all the current alarm thresholds
.1.3.6.1.4.1.3607.5.90.1.1Describes the requirements for conformance to the High Capacity Media Independent Group.
.1.3.6.1.4.1.3607.2.100.10.1.20This is the configured maximum value of the soak timer for this interface.
.1.3.6.1.4.1.3607.2.100.10.1.30This is the current value of the soak timer for this interface. The difference between cerntIfExtConfiguredSoakTime and this object gives the time duration for which this interface has had a good signal.
.1.3.6.1.4.1.3607.2.100.10.1Row definition for cerentIfExtTable
.1.3.6.1.4.1.3607.2.100.10.1.10This object can be set through a management interface. When the administrative state of this interface is 'down', the value of this object does not have any impact. When the administrative state of this interface is 'up', if this object has a value of 'false', an alarm on this interface will be reported. If the value of this object is 'true' then all alarms on this interface will be suppressed. If the interface has a good signal, the soak timer will be started, if the port is faulted before the soak timer expires, the soak timer will be reset to the provisioned maximum value. If the soak timer expires then the value of this object is automatically set to 'false'.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.