CERENT-ENVMON-MIB
Imported Objects
Objects
22 total| Object Name |
|---|
cerentEnvMonMIB MODULE-IDENTITY .1.3.6.1.4.1.3607.1.10.120 |
cerentEnvMonObjects OBJECT IDENTIFIER .1.3.6.1.4.1.3607.2.80 |
cerentEnvMonVoltageStatsTable SEQUENCE OF CerentEnvMonVoltageStatsEntry .1.3.6.1.4.1.3607.2.80.10 |
cerentEnvMonVoltageStatsEntry CerentEnvMonVoltageStatsEntry .1.3.6.1.4.1.3607.2.80.10.1 |
cerentEnvMonVoltageStatsIndex Integer32 .1.3.6.1.4.1.3607.2.80.10.1.10 |
cerentEnvMonVoltageStatsDescrro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3607.2.80.10.1.20 |
cerentEnvMonVoltageStatsCurrentValuero Integer32 UNITS "millivolts" .1.3.6.1.4.1.3607.2.80.10.1.30 |
cerentEnvMonVoltageStatsThresholdVeryHighro Integer32 UNITS "millivolts" .1.3.6.1.4.1.3607.2.80.10.1.40 |
cerentEnvMonVoltageStatsThresholdHighro Integer32 UNITS "millivolts" .1.3.6.1.4.1.3607.2.80.10.1.50 |
cerentEnvMonVoltageStatsThresholdLowro Integer32 UNITS "millivolts" .1.3.6.1.4.1.3607.2.80.10.1.60 |
cerentEnvMonVoltageStatsThresholdVeryLowro Integer32 UNITS "millivolts" .1.3.6.1.4.1.3607.2.80.10.1.70 |
cerentEnvMonTemperatureStatsTable SEQUENCE OF CerentEnvMonTemperatureStatsEntry .1.3.6.1.4.1.3607.2.80.20 |
cerentEnvMonTemperatureStatsEntry CerentEnvMonTemperatureStatsEntry .1.3.6.1.4.1.3607.2.80.20.1 |
cerentEnvMonTemperatureStatsIndex Integer32 .1.3.6.1.4.1.3607.2.80.20.1.10 |
cerentEnvMonTemperatureStatsDescrro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3607.2.80.20.1.20 |
cerentEnvMonTemperatureStatsCurrentValuero Gauge32 UNITS "Degree Celsius" .1.3.6.1.4.1.3607.2.80.20.1.30 |
cerentEnvMonTemperatureStatsThresholdHighro Gauge32 UNITS "Degree Celsius" .1.3.6.1.4.1.3607.2.80.20.1.40 |
cerentEnvMonMibConformance OBJECT IDENTIFIER .1.3.6.1.4.1.3607.5.70 |
cerentEnvMonMibCompliance OBJECT IDENTIFIER .1.3.6.1.4.1.3607.5.70.10 |
cerentEnvMonMibBasicCompliance Unknown .1.3.6.1.4.1.3607.5.70.10.10 |
cerentEnvMonMibGroups OBJECT IDENTIFIER .1.3.6.1.4.1.3607.5.70.20 |
cerentEnvMonMibObjectsGroup Unknown .1.3.6.1.4.1.3607.5.70.20.10 |
CERENT-ENVMON-MIB Technical Reference Overview
The CERENT-ENVMON-MIB SNMP MIB module published by Cisco defines 22 managed OID objects, including 13 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.3607.1.10.120. Key tabular structures include cerentEnvMonTemperatureStatsTable, cerentEnvMonVoltageStatsTable.
Key OID Definitions in CERENT-ENVMON-MIB
.1.3.6.1.4.1.3607.1.10.120This MIB module provides Environmental status information
.1.3.6.1.4.1.3607.2.80.20This table provides ambient temperature information as measured by the temperature sensors.
.1.3.6.1.4.1.3607.2.80.10This table maintains the status info for all EnvMon related voltages picked up by the sensors in the device.
.1.3.6.1.4.1.3607.5.70.10.10The basic implementation requirements for all Cisco ONS network devices.
.1.3.6.1.4.1.3607.5.70.20.10All NMS accessible objects
.1.3.6.1.4.1.3607.5.70.10The compliance statements for Cisco ONS devices.
.1.3.6.1.4.1.3607.5.70This node is created for compliance. Has objects as required by the RFCs
.1.3.6.1.4.1.3607.5.70.20All the objects and events are grouped under this for conformance
.1.3.6.1.4.1.3607.2.80.20.1.30Current Temperature measurement at this temperature sensor.
.1.3.6.1.4.1.3607.2.80.20.1.20Unique Name/Description of the temperature sensor.
.1.3.6.1.4.1.3607.2.80.20.1Each temperature is represented by a row in the table.
.1.3.6.1.4.1.3607.2.80.20.1.10The value index uniquely indicates the temperature sensor in the device.
.1.3.6.1.4.1.3607.2.80.20.1.40If the current temperature value exceeds this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable.
.1.3.6.1.4.1.3607.2.80.10.1.30Current voltage measurement at this voltage sensor.
.1.3.6.1.4.1.3607.2.80.10.1.20Unique Name/Description of the voltage sensor.
.1.3.6.1.4.1.3607.2.80.10.1There will as many rows as there are sensors in the device.
.1.3.6.1.4.1.3607.2.80.10.1.10The value index uniquely indicates the voltage sensor in the device.
.1.3.6.1.4.1.3607.2.80.10.1.50If the current voltage value exceeds this threshold value, a warning event will be raised by the device. The severity of this event may be provisionable.
.1.3.6.1.4.1.3607.2.80.10.1.60If the current voltage value falls below this threshold value, a warning event will be raised by the device. The severity of this event may be provisionable.
.1.3.6.1.4.1.3607.2.80.10.1.40If the current voltage value exceeds this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable.
.1.3.6.1.4.1.3607.2.80.10.1.70If the current voltage value falls below this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.