Home/Catalog/CERENT-ENVMON-MIB

CERENT-ENVMON-MIB

This MIB module provides Environmental status information
Main OID:
cerentEnvMonMIB.1.3.6.1.4.1.3607.1.10.120
22
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

22 total
Object Name
cerentEnvMonMIBThis MIB module provides Environmental status information
MODULE-IDENTITY
.1.3.6.1.4.1.3607.1.10.120
cerentEnvMonObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.2.80
cerentEnvMonVoltageStatsTableThis table maintains the status info for all EnvMon related voltages picked up by the sensors in the device.
SEQUENCE OF CerentEnvMonVoltageStatsEntry
.1.3.6.1.4.1.3607.2.80.10
cerentEnvMonVoltageStatsEntryThere will as many rows as there are sensors in the device.
CerentEnvMonVoltageStatsEntry
.1.3.6.1.4.1.3607.2.80.10.1
cerentEnvMonVoltageStatsIndexThe value index uniquely indicates the voltage sensor in the device.
Integer32
.1.3.6.1.4.1.3607.2.80.10.1.10
cerentEnvMonVoltageStatsDescrUnique Name/Description of the voltage sensor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.80.10.1.20
cerentEnvMonVoltageStatsCurrentValueCurrent voltage measurement at this voltage sensor.ro
Integer32 UNITS "millivolts"
.1.3.6.1.4.1.3607.2.80.10.1.30
cerentEnvMonVoltageStatsThresholdVeryHighIf the current voltage value exceeds this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable.ro
Integer32 UNITS "millivolts"
.1.3.6.1.4.1.3607.2.80.10.1.40
cerentEnvMonVoltageStatsThresholdHighIf the current voltage value exceeds this threshold value, a warning event will be raised by the device. The severity of this event may be provisionable.ro
Integer32 UNITS "millivolts"
.1.3.6.1.4.1.3607.2.80.10.1.50
cerentEnvMonVoltageStatsThresholdLowIf the current voltage value falls below this threshold value, a warning event will be raised by the device. The severity of this event may be provisionable.ro
Integer32 UNITS "millivolts"
.1.3.6.1.4.1.3607.2.80.10.1.60
cerentEnvMonVoltageStatsThresholdVeryLowIf the current voltage value falls below this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable.ro
Integer32 UNITS "millivolts"
.1.3.6.1.4.1.3607.2.80.10.1.70
cerentEnvMonTemperatureStatsTableThis table provides ambient temperature information as measured by the temperature sensors.
SEQUENCE OF CerentEnvMonTemperatureStatsEntry
.1.3.6.1.4.1.3607.2.80.20
cerentEnvMonTemperatureStatsEntryEach temperature is represented by a row in the table.
CerentEnvMonTemperatureStatsEntry
.1.3.6.1.4.1.3607.2.80.20.1
cerentEnvMonTemperatureStatsIndexThe value index uniquely indicates the temperature sensor in the device.
Integer32
.1.3.6.1.4.1.3607.2.80.20.1.10
cerentEnvMonTemperatureStatsDescrUnique Name/Description of the temperature sensor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3607.2.80.20.1.20
cerentEnvMonTemperatureStatsCurrentValueCurrent Temperature measurement at this temperature sensor.ro
Gauge32 UNITS "Degree Celsius"
.1.3.6.1.4.1.3607.2.80.20.1.30
cerentEnvMonTemperatureStatsThresholdHighIf the current temperature value exceeds this threshold value, an alarm event will be raised by the device. The severity of this event may be provisionable.ro
Gauge32 UNITS "Degree Celsius"
.1.3.6.1.4.1.3607.2.80.20.1.40
cerentEnvMonMibConformanceThis node is created for compliance. Has objects as required by the RFCs
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.5.70
cerentEnvMonMibComplianceThe compliance statements for Cisco ONS devices.
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.5.70.10
cerentEnvMonMibBasicComplianceThe basic implementation requirements for all Cisco ONS network devices.
Unknown
.1.3.6.1.4.1.3607.5.70.10.10
cerentEnvMonMibGroupsAll the objects and events are grouped under this for conformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.3607.5.70.20
cerentEnvMonMibObjectsGroupAll NMS accessible objects
Unknown
.1.3.6.1.4.1.3607.5.70.20.10