CERENT-454-MIB
Imported Objects
Objects
364 total| Object Name |
|---|
cerent454MibModule MODULE-IDENTITY .1.3.6.1.4.1.3607.1.10.20 |
cerent454Mib OBJECT IDENTIFIER .1.3.6.1.4.1.3607.6.10 |
cerent454Conformance OBJECT IDENTIFIER .1.3.6.1.4.1.3607.6.10.10 |
cerent454Groups OBJECT IDENTIFIER .1.3.6.1.4.1.3607.6.10.10.10 |
cerent454Compliance OBJECT IDENTIFIER .1.3.6.1.4.1.3607.6.10.10.20 |
cerent454Objects OBJECT IDENTIFIER .1.3.6.1.4.1.3607.6.10.20 |
cerent454GeneralGroup OBJECT IDENTIFIER .1.3.6.1.4.1.3607.6.10.20.20 |
cerent454SoftwareVersionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3607.6.10.20.20.10 |
cerent454AlarmGroup OBJECT IDENTIFIER .1.3.6.1.4.1.3607.6.10.20.30 |
cerent454AlarmCountro Unsigned32 .1.3.6.1.4.1.3607.6.10.20.30.10 |
cerent454AlarmTable SEQUENCE OF Cerent454AlarmEntry .1.3.6.1.4.1.3607.6.10.20.30.20 |
cerent454AlarmEntry Cerent454AlarmEntry .1.3.6.1.4.1.3607.6.10.20.30.20.1 |
cerent454AlarmIndex Integer32 ( 1..2147483647 ) -- all +ve values .1.3.6.1.4.1.3607.6.10.20.30.20.1.10 |
cerent454AlarmObjectTypero Cerent454EntityClass .1.3.6.1.4.1.3607.6.10.20.30.20.1.20 |
cerent454AlarmSlotNumberro Integer32 .1.3.6.1.4.1.3607.6.10.20.30.20.1.30 |
cerent454AlarmPortNumberro Integer32 .1.3.6.1.4.1.3607.6.10.20.30.20.1.40 |
cerent454AlarmLineNumberro Integer32 .1.3.6.1.4.1.3607.6.10.20.30.20.1.50 |
cerent454AlarmObjectIndexro Integer32 .1.3.6.1.4.1.3607.6.10.20.30.20.1.60 |
cerent454AlarmTypero Cerent454AlarmType .1.3.6.1.4.1.3607.6.10.20.30.20.1.70 |
cerent454AlarmStatero CerentNotificationClass (CERENT-TC) .1.3.6.1.4.1.3607.6.10.20.30.20.1.80 |
cerent454AlarmTimeStampro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.3607.6.10.20.30.20.1.90 |
cerent454AlarmObjectNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3607.6.10.20.30.20.1.100 |
cerent454Events OBJECT IDENTIFIER .1.3.6.1.4.1.3607.6.10.30 |
cerent454V2Events OBJECT IDENTIFIER .1.3.6.1.4.1.3607.6.10.30.0 |
alarmUnknown NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.1 |
alarmCutoffIsInManualMode NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.10 |
failureDetectedExternalToTheNE NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.20 |
externalError NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.30 |
excessiveSwitching NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.40 |
terminationFailureSDCC NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.50 |
incomingFailureCondition NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.60 |
alarmIndicationSignal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.70 |
alarmIndicationSignalLine NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.80 |
alarmIndicationSignalPath NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.90 |
alarmIndicationSignalVT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.100 |
channelFailureAPS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.110 |
channelByteFailureAPS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.120 |
channelProtectionSwitchingChannelMatchFailureAPS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.130 |
channelAutomaticProtectionSwitchModeMismatchAPS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.140 |
channelFarEndProtectionLineFailureAPS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.150 |
channelBLSRInconsistentAPSCode NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.160 |
channelBLSRImproperAPSCodeAPS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.170 |
channelBLSRNodeIdMismatchAPS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.180 |
channelBLSRDefaultKAPS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.190 |
channelBLSRConnectionLossAPS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.200 |
bipolarViolation NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.210 |
carrierLossOnTheLAN NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.220 |
concatenationErrorSTS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.230 |
excessCollisionsOnTheLAN NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.240 |
facilityCriticalAlarmCausedByDS3FacilityFailure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.250 |
farEndAIS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.260 |
farEndMultipleDS1LOSDetectedOnDS3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.270 |
farEndDS1EqptFailNonServiceAffecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.280 |
farEndDS1EqptFailServiceAffecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.290 |
farEndSingleDS1LOS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.300 |
farEndDS3EqptFailNonServiceAffecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.310 |
farEndDS3EqptFailServiceAffecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.320 |
farEndCmnEqptFailNonServiceAffecting NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.330 |
farEndIDLE NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.340 |
farEndLOS NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.350 |
farEndLOF NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.360 |
farEndBlockError NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.370 |
idleConditionDS3 NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.380 |
lossOfFrame NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.390 |
lossOfPointer NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.400 |
lossOfPointerPath NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.410 |
lossOfPointerVT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.420 |
lossOfSignal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.430 |
outOfFrame NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.440 |
pathSelectorInabilityToSwitchToAValidSignal NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.450 |
remoteAlarmIndication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.460 |
remoteFailureIndication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.470 |
remoteFailureIndicationLine NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.480 |
remoteFailureIndicationPath NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.490 |
remoteFailureIndicationVT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.500 |
facilityHasPassedBERThresholdForSignalDegrade NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.510 |
severelyErroredFrame NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.520 |
facilityHasPassedBERThresholdForSignalFailure NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.530 |
signalLabelMismatchFailuresSONET NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.540 |
signalLabelMismatchFailurePayloadDefectIndication NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.550 |
signalLabelMismatchFailurePayloadDefectIndicationPath NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.560 |
signalLabelMismatchFailurePayloadLabelMismatchPath NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.570 |
signalLabelMismatchFailurePayloadLabelMismatchVT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.580 |
signalLabelMismatchFailureUnequippedPath NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.590 |
signalLabelMismatchFailureUnequippedVT NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.600 |
lossOfTimingOnSynchronizationLink NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.610 |
lossOfTimingOnAllSpecifiedSynchronizationLinks NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.620 |
lossOfTimingOnPrimarySynchronizationLink NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.630 |
lossOfTimingOnSecondarySynchronizationLink NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.640 |
lossOfTimingOnThirdSynchronizationLink NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.650 |
lossOfTimingOnFourthSynchronizationLink NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.660 |
lossOfTimingOnFifthSynchronizationLink NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.670 |
lossOfTimingOnSixthSynchronizationLink NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.680 |
failedToReceiveSynchronizationStatusMessage NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.690 |
synchronizationStatusMessagesAreDisabledOnThisInterface NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.700 |
primaryReferenceSourceStratum1Traceable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.710 |
synchronizedTraceabilityUnknown NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.720 |
stratum2Traceable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.730 |
transitNodeClockTraceable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.740 |
stratum3ETraceable NOTIFICATION-TYPE .1.3.6.1.4.1.3607.6.10.30.0.750 |
CERENT-454-MIB Technical Reference Overview
The CERENT-454-MIB SNMP MIB module published by Cisco defines 364 managed OID objects, including 16 scalar/column metrics, 1 SNMP tables, and 333 trap/notification events anchored at base OID .1.3.6.1.4.1.3607.1.10.20. Key tabular structures include cerent454AlarmTable. Monitored SNMP traps/notifications include alarmUnknown, alarmCutoffIsInManualMode, failureDetectedExternalToTheNE, externalError, excessiveSwitching, terminationFailureSDCC.
Key OID Definitions in CERENT-454-MIB
.1.3.6.1.4.1.3607.1.10.20This module provides the definitions for objects for managing Cisco OTBU ONS 15454.
.1.3.6.1.4.1.3607.6.10.20.30.20This table holds all the current raised alarms. When an alarm is raised, it will appear a new entry in the table. Whenever an alarm is cleared it will be removed from the table and all the entries from below will be moved up by another row.
.1.3.6.1.4.1.3607.6.10.30.0.1alarm unknown
.1.3.6.1.4.1.3607.6.10.30.0.10alarm cutoff is in manual mode
.1.3.6.1.4.1.3607.6.10.30.0.20failure detected External to the NE
.1.3.6.1.4.1.3607.6.10.30.0.30external error
.1.3.6.1.4.1.3607.6.10.30.0.40excessive switching
.1.3.6.1.4.1.3607.6.10.30.0.50SDCC Termination failure
.1.3.6.1.4.1.3607.6.10.30.0.60incoming failure condition
.1.3.6.1.4.1.3607.6.10.30.0.70alarm indication signal
.1.3.6.1.4.1.3607.6.10.30.0.80alarm indication signal LINE
.1.3.6.1.4.1.3607.6.10.30.0.90alarm indication signal Path
.1.3.6.1.4.1.3607.6.10.30.0.100alarm indication signal VT
.1.3.6.1.4.1.3607.6.10.30.0.110channel failure APS
.1.3.6.1.4.1.3607.6.10.30.0.120channel Byte failure APS
.1.3.6.1.4.1.3607.6.10.30.0.130channel Protection Switching Channel Match failure APS
.1.3.6.1.4.1.3607.6.10.30.0.140channel Automatic Protection Switch Mode Mismatch APS
.1.3.6.1.4.1.3607.6.10.30.0.150channel far end protection line failure APS
.1.3.6.1.4.1.3607.6.10.30.0.160channel BLSR inconsistent APS code
.1.3.6.1.4.1.3607.6.10.30.0.170channel BLSR Improper APS code APS
.1.3.6.1.4.1.3607.6.10.30.0.180channel BLSR Node Id Mismatch APS
.1.3.6.1.4.1.3607.6.10.30.0.190channel BLSR Default K APS
.1.3.6.1.4.1.3607.6.10.30.0.200channel BLSR Connection loss APS
.1.3.6.1.4.1.3607.6.10.30.0.210bipolar Violation
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.