CENTRECOM-SYSTEM-MIB

AI MIB Summary

The CENTRECOM-SYSTEM-MIB provides SNMP access to system-level management objects for Atkk (Centrecom) switches, enabling monitoring of device status, operational parameters, and hardware health metrics.

Atkk Switch System objects
Main OID:
atiSwitchSystem.1.3.6.1.4.1.207.8.12.2.3
22
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

22 total
Object Name
atiSwitchSystem
MODULE-IDENTITY
.1.3.6.1.4.1.207.8.12.2.3
SNMPv2-SMI
Unknown
.1.3.6.1.4.1.207.8.12.2.3
atiSaveConfigurationrw
Enumeration
.1.3.6.1.4.1.207.8.12.2.3.3
atiSaveStatusro
Enumeration
.1.3.6.1.4.1.207.8.12.2.3.4
atiCurrentConfigInUsero
Enumeration
.1.3.6.1.4.1.207.8.12.2.3.5
atiConfigToUseOnRebootrw
Enumeration
.1.3.6.1.4.1.207.8.12.2.3.6
atiOverTemperatureAlarmro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.207.8.12.2.3.7
atiCurrentTemperaturero
INTEGER
.1.3.6.1.4.1.207.8.12.2.3.8
atiFanStatusTable
SEQUENCE OF AtiFanStatusEntry
.1.3.6.1.4.1.207.8.12.2.3.9
atiFanStatusEntry
AtiFanStatusEntry
.1.3.6.1.4.1.207.8.12.2.3.9.1
atiFanNumberro
INTEGER
.1.3.6.1.4.1.207.8.12.2.3.9.1.1
atiFanOperationalro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.207.8.12.2.3.9.1.2
atiPrimaryPowerOperationalro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.207.8.12.2.3.10
atiRedundantPowerStatusro
Enumeration
.1.3.6.1.4.1.207.8.12.2.3.11
atiRedundantPowerAlarmro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.207.8.12.2.3.12
atiPrimarySoftwareRevro
DisplayString
.1.3.6.1.4.1.207.8.12.2.3.13
atiSecondarySoftwareRevro
DisplayString
.1.3.6.1.4.1.207.8.12.2.3.14
atiImageToUseOnRebootrw
Enumeration
.1.3.6.1.4.1.207.8.12.2.3.15
atiSystemIDro
DisplayString
.1.3.6.1.4.1.207.8.12.2.3.16
atiSystemBoardIDro
DisplayString
.1.3.6.1.4.1.207.8.12.2.3.17
atiSystemLeftBoardIDro
DisplayString
.1.3.6.1.4.1.207.8.12.2.3.18
atiSystemRightBoardIDro
DisplayString
.1.3.6.1.4.1.207.8.12.2.3.19

CENTRECOM-SYSTEM-MIB Technical Reference Overview

The CENTRECOM-SYSTEM-MIB SNMP MIB module published by Allied Telesis defines 22 managed OID objects, including 19 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.207.8.12.2.3. Key tabular structures include atiFanStatusTable.

Key OID Definitions in CENTRECOM-SYSTEM-MIB

atiSwitchSystemMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.207.8.12.2.3

Atkk Switch System objects

atiFanStatusTableSEQUENCEnot-accessible
.1.3.6.1.4.1.207.8.12.2.3.9

Table of operational status of all internal cooling fans.

SNMPv2-SMIunknownunknown
.1.3.6.1.4.1.207.8.12.2.3

Atkk Switch System objects

atiSaveConfigurationINTEGERwrite-only
.1.3.6.1.4.1.207.8.12.2.3.3

When this object is set, the device will copy the contents of the configuration database to a buffer and save it to the persistant store specified by the value of the object. The save is performed asynchronously, and the snmp agent will continue to respond to both gets and sets while the save is taking place. A network management application may use the atiSaveStatus object to determine when the asynchronous save operation has completed.

atiSaveStatusINTEGERread-only
.1.3.6.1.4.1.207.8.12.2.3.4

This object will return the status of a save operation invoked by setting the atiSaveConfiguration object. A network management application can read this object to determine that a save operation has completed.

atiCurrentConfigInUseINTEGERread-only
.1.3.6.1.4.1.207.8.12.2.3.5

Shows which NVRAM configuration store was used at last boot

atiConfigToUseOnRebootINTEGERread-write
.1.3.6.1.4.1.207.8.12.2.3.6

Controls which NVRAM configuration store will be used on next reboot.

atiOverTemperatureAlarmTruthValueread-only
.1.3.6.1.4.1.207.8.12.2.3.7

Alarm status of overtemperature sensor in device enclosure.

atiCurrentTemperatureINTEGERread-only
.1.3.6.1.4.1.207.8.12.2.3.8

Current temperature in degrees celcius measured inside device enclosure.

atiPrimaryPowerOperationalTruthValueread-only
.1.3.6.1.4.1.207.8.12.2.3.10

Operational status of internal power supply of a device.

atiRedundantPowerStatusINTEGERread-only
.1.3.6.1.4.1.207.8.12.2.3.11

Operational status of an external redundant power supply to a device.

atiRedundantPowerAlarmTruthValueread-only
.1.3.6.1.4.1.207.8.12.2.3.12

Alarm state of an external redundant power supply to a device. Alarm state indicates either fan failure or overtemperature condition.

atiPrimarySoftwareRevDisplayStringread-only
.1.3.6.1.4.1.207.8.12.2.3.13

The software revision of the primary image stored in this device. This string will have a zero length if the revision is unknown, invalid or not present. This will also be reported in RMON2 probeSoftwareRev if this is the software image currently running in the device.

atiSecondarySoftwareRevDisplayStringread-only
.1.3.6.1.4.1.207.8.12.2.3.14

The software revision of the secondary image stored in this device. This string will have a zero length if the revision is unknown, invalid or not present. This will also be reported in RMON2 probeSoftwareRev if this is the software image currently running in the device.

atiImageToUseOnRebootINTEGERread-write
.1.3.6.1.4.1.207.8.12.2.3.15

Controls which image will be used on next reboot.

atiSystemIDDisplayStringread-only
.1.3.6.1.4.1.207.8.12.2.3.16

This represents the System ID of the Switch.

atiSystemBoardIDDisplayStringread-only
.1.3.6.1.4.1.207.8.12.2.3.17

This represents the Board ID of the Switch.

atiSystemLeftBoardIDDisplayStringread-only
.1.3.6.1.4.1.207.8.12.2.3.18

This represents the Left Board ID of the Summit Switch.

atiSystemRightBoardIDDisplayStringread-only
.1.3.6.1.4.1.207.8.12.2.3.19

This represents the Right Board ID of the Summit Switch.

atiFanStatusEntryAtiFanStatusEntrynot-accessible
.1.3.6.1.4.1.207.8.12.2.3.9.1

Entry in table of all internal cooling fans.

atiFanNumberINTEGERread-only
.1.3.6.1.4.1.207.8.12.2.3.9.1.1

Identifier of cooling fan, numbered from the front and/or left side of device.

atiFanOperationalTruthValueread-only
.1.3.6.1.4.1.207.8.12.2.3.9.1.2

Operational status of a cooling fan.

More MIBs from Allied Telesis

Browse all Allied TelesisMIBs →
AT-UWC-WLAN-SWITCH-MIB

The AT-UWC-WLAN-SWITCH-MIB provides vendor-specific SNMP management for Allied Telesis Universal Wireless Controller (UWC) hardware, enabling monitoring of WLAN switch operational states, interface statistics, and wireless client association metrics.

1459 objects→
AtiEdgeSwitch-MIB

The AtiEdgeSwitch-MIB provides vendor-specific SNMP extensions for monitoring and managing Layer 2 stackable switch operations, including interface status, port statistics, and stack topology, on ATI hardware platforms within Windows and UNIX network management environments.

924 objects→
ALLIEDTELESYN-MIB

Standard SNMP MIB module defining data structures for ALLIEDTELESYN-MIB.

772 objects→
AT-BOARDS-MIB

The AT-BOARDS-MIB module provides a structured OID hierarchy for monitoring and managing specific hardware components on Allied Telesis devices, including board identifiers, firmware release versions, interface type definitions, and integrated chip IDs. This MIB enables granular inventory tracking and hardware status verification by mapping logical identifiers to physical subsystems within the network equipment chassis.

328 objects→
SWITCH-ATM-MIB

SWITCH-ATM-MIB monitors and manages Asynchronous Transfer Mode (ATM) interfaces and virtual circuit states on network switches, specifically tracking VPI/VCI pairings and traffic counters under the constraint that the Virtual Path Identifier is fixed by the implementation and excluded from table indexing.

263 objects→
AtiL2-MIB

Standard SNMP MIB module defining data structures for AtiL2-MIB.

239 objects→