CAT2600-MIB
Standard SNMP MIB module defining data structures for CAT2600-MIB.
Imported Objects
Objects
151 total| Object Name |
|---|
cisco OBJECT IDENTIFIER .1.3.6.1.4.1.9 |
RFC1155-SMI Unknown .1.3.6.1.4.1.9 |
catProd OBJECT IDENTIFIER .1.3.6.1.4.1.9.1 |
cat2600 OBJECT IDENTIFIER .1.3.6.1.4.1.9.1.111 |
cat2600Ts OBJECT IDENTIFIER .1.3.6.1.4.1.9.1.111.1 |
cat2600TsObjectID OBJECT IDENTIFIER .1.3.6.1.4.1.9.1.111.1.1 |
cat2600TsSysObjectID OBJECT IDENTIFIER .1.3.6.1.4.1.9.1.111.1.1.1 |
cat2600TsObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.1.111.1.2 |
cat2600TsMain OBJECT IDENTIFIER .1.3.6.1.4.1.9.1.111.1.2.1 |
cat2600TsConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.1.111.1.2.1.1 |
cat2600TsFwVerro DisplayString .1.3.6.1.4.1.9.1.111.1.2.1.1.1 |
cat2600TsHwVerro DisplayString .1.3.6.1.4.1.9.1.111.1.2.1.1.2 |
cat2600TsSerialNumberro DisplayString .1.3.6.1.4.1.9.1.111.1.2.1.1.3 |
cat2600TsInstallationDaterw DisplayString .1.3.6.1.4.1.9.1.111.1.2.1.1.4 |
cat2600TsFwSizero INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.1.5 |
cat2600TsFwCRCro INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.1.6 |
cat2600TsFwManufacturerro DisplayString .1.3.6.1.4.1.9.1.111.1.2.1.1.7 |
cat2600TsIpAddrrw IpAddress .1.3.6.1.4.1.9.1.111.1.2.1.1.8 |
cat2600TsNetMaskrw IpAddress .1.3.6.1.4.1.9.1.111.1.2.1.1.9 |
cat2600TsDefaultGatewayrw IpAddress .1.3.6.1.4.1.9.1.111.1.2.1.1.10 |
cat2600TsTrapRcvrTable SEQUENCE OF Cat2600TsTrapRcvrEntry .1.3.6.1.4.1.9.1.111.1.2.1.1.14 |
cat2600TsTrapRcvrEntry Cat2600TsTrapRcvrEntry .1.3.6.1.4.1.9.1.111.1.2.1.1.14.1 |
cat2600TsTrapRcvrIndexro INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.1.14.1.1 |
cat2600TsTrapRcvrStatusrw Enumeration .1.3.6.1.4.1.9.1.111.1.2.1.1.14.1.2 |
cat2600TsTrapRcvrIpAddressrw IpAddress .1.3.6.1.4.1.9.1.111.1.2.1.1.14.1.3 |
cat2600TsTrapRcvrCommrw DisplayString .1.3.6.1.4.1.9.1.111.1.2.1.1.14.1.4 |
cat2600TsTrapRcvrDmnsrw OCTET STRING .1.3.6.1.4.1.9.1.111.1.2.1.1.14.1.5 |
cat2600TsPingIntervalrw INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.1.19 |
cat2600TsTapPortrw INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.1.20 |
cat2600TsTapMonitoredPortrw INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.1.21 |
cat2600TsCrcThresholdHirw INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.1.22 |
cat2600TsCrcThresholdLowrw INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.1.23 |
cat2600TsPortSwitchModeChangeTrapEnablerw Enumeration .1.3.6.1.4.1.9.1.111.1.2.1.1.24 |
cat2600TsTrendThresholdrw INTEGER -- ?? .1.3.6.1.4.1.9.1.111.1.2.1.1.25 |
cat2600TsSamplingPeriodrw INTEGER (1 ..120) .1.3.6.1.4.1.9.1.111.1.2.1.1.26 |
cat2600TsNumberUFCro INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.1.27 |
cat2600TsSys OBJECT IDENTIFIER .1.3.6.1.4.1.9.1.111.1.2.1.2 |
cat2600TsNumPortsro INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.2.1 |
cat2600TsNumStationsro INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.2.2 |
cat2600TsMostStationsro INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.2.3 |
cat2600TsMaxStationsro INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.2.4 |
cat2600TsResetrw Enumeration .1.3.6.1.4.1.9.1.111.1.2.1.2.5 |
cat2600TsNumResetsro Counter .1.3.6.1.4.1.9.1.111.1.2.1.2.6 |
cat2600TsAddrAgingTimerw INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.2.7 |
cat2600TsSysTemperaturero Enumeration .1.3.6.1.4.1.9.1.111.1.2.1.2.11 |
cat2600TsInstalledMemoryro INTEGER .1.3.6.1.4.1.9.1.111.1.2.1.2.12 |
cat2600TsSysCurTimerw DisplayString .1.3.6.1.4.1.9.1.111.1.2.1.2.13 |
cat2600TsPort OBJECT IDENTIFIER .1.3.6.1.4.1.9.1.111.1.2.2 |
cat2600TsPortTable SEQUENCE OF Cat2600TsPortEntry .1.3.6.1.4.1.9.1.111.1.2.2.1 |
cat2600TsPortEntry Cat2600TsPortEntry .1.3.6.1.4.1.9.1.111.1.2.2.1.1 |
cat2600TsPortIndexro INTEGER .1.3.6.1.4.1.9.1.111.1.2.2.1.1.1 |
cat2600TsPortRcvLocalFramesro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.2 |
cat2600TsPortForwardedFramesro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.3 |
cat2600TsPortMostStationsro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.4 |
cat2600TsPortMaxStationsro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.5 |
cat2600TsPortSWHandledFramesro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.6 |
cat2600TsPortLocalStationsro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.7 |
cat2600TsPortRemoteStationsro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.8 |
cat2600TsPortUnknownStaFramesro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.9 |
cat2600TsPortResetStatsrw Enumeration .1.3.6.1.4.1.9.1.111.1.2.2.1.1.10 |
cat2600TsPortResetTimerro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.9.1.111.1.2.2.1.1.11 |
cat2600TsPortResetAddrsrw Enumeration .1.3.6.1.4.1.9.1.111.1.2.2.1.1.12 |
cat2600TsPortRcvBcastsro Counter -- ?? RFC1573 bcst frames ?? .1.3.6.1.4.1.9.1.111.1.2.2.1.1.13 |
cat2600TsPortSwitchedFramesro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.14 |
cat2600TsPortLinkStatero Enumeration .1.3.6.1.4.1.9.1.111.1.2.2.1.1.15 |
cat2600TsPortHashOverflowsro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.16 |
cat2600TsPortAddrAgingTimerw INTEGER .1.3.6.1.4.1.9.1.111.1.2.2.1.1.17 |
cat2600TsPortSwitchModerw Enumeration .1.3.6.1.4.1.9.1.111.1.2.2.1.1.18 |
cat2600TsPortFixedCfgrw Enumeration .1.3.6.1.4.1.9.1.111.1.2.2.1.1.19 |
cat2600TsPortModerw Enumeration .1.3.6.1.4.1.9.1.111.1.2.2.1.1.20 |
cat2600TsPortDuplexrw Enumeration .1.3.6.1.4.1.9.1.111.1.2.2.1.1.21 |
cat2600TsPortCfgLossro INTEGER .1.3.6.1.4.1.9.1.111.1.2.2.1.1.22 |
cat2600TsPortCfgLossRCro Enumeration .1.3.6.1.4.1.9.1.111.1.2.2.1.1.23 |
cat2600TsPortCRCCountro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.24 |
cat2600TsPortHPChannelFramesro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.25 |
cat2600TsPortLPChannelFramesro Counter .1.3.6.1.4.1.9.1.111.1.2.2.1.1.26 |
cat2600TsPortHPThresholdro INTEGER .1.3.6.1.4.1.9.1.111.1.2.2.1.1.27 |
cat2600TsPortCfgRingSpeedrw Enumeration .1.3.6.1.4.1.9.1.111.1.2.2.1.1.28 |
cat2600TsPortCfgRSArw Enumeration .1.3.6.1.4.1.9.1.111.1.2.2.1.1.29 |
cat2600TsPortDomainro INTEGER .1.3.6.1.4.1.9.1.111.1.2.2.1.1.30 |
cat2600TsPortCfgLossThresholdrw INTEGER .1.3.6.1.4.1.9.1.111.1.2.2.1.1.31 |
cat2600TsPortCfgLossSamplingPeriodrw INTEGER .1.3.6.1.4.1.9.1.111.1.2.2.1.1.32 |
cat2600TsPortBeaconStationAddress MacAddr .1.3.6.1.4.1.9.1.111.1.2.2.1.1.33 |
cat2600TsPortBeaconNAUN MacAddr .1.3.6.1.4.1.9.1.111.1.2.2.1.1.34 |
cat2600TsPortBeaconType INTEGER .1.3.6.1.4.1.9.1.111.1.2.2.1.1.35 |
cat2600TsOptPortStaTable SEQUENCE OF Cat2600TsOptPortStaEntry .1.3.6.1.4.1.9.1.111.1.2.2.2 |
cat2600TsOptPortStaEntry Cat2600TsOptPortStaEntry .1.3.6.1.4.1.9.1.111.1.2.2.2.1 |
cat2600TsOptPortStaPosro INTEGER .1.3.6.1.4.1.9.1.111.1.2.2.2.1.1 |
cat2600TsOptPortStaValro OCTET STRING .1.3.6.1.4.1.9.1.111.1.2.2.2.1.2 |
cat2600TsPortStnTable SEQUENCE OF Cat2600TsPortStnEntry .1.3.6.1.4.1.9.1.111.1.2.2.3 |
cat2600TsPortStnEntry Cat2600TsPortStnEntry .1.3.6.1.4.1.9.1.111.1.2.2.3.1 |
cat2600TsPortStnPortNumro INTEGER .1.3.6.1.4.1.9.1.111.1.2.2.3.1.1 |
cat2600TsPortStnAddressro MacAddr .1.3.6.1.4.1.9.1.111.1.2.2.3.1.2 |
cat2600TsPortStnLocationro Enumeration .1.3.6.1.4.1.9.1.111.1.2.2.3.1.3 |
cat2600TsPortStnSrcFramesro Counter .1.3.6.1.4.1.9.1.111.1.2.2.3.1.4 |
cat2600TsPortStnSrcBytesro Counter .1.3.6.1.4.1.9.1.111.1.2.2.3.1.5 |
cat2600TsPortStnDestnFramesro Counter .1.3.6.1.4.1.9.1.111.1.2.2.3.1.6 |
cat2600TsPortStnDestnBytesro Counter .1.3.6.1.4.1.9.1.111.1.2.2.3.1.7 |
cat2600TsDmns OBJECT IDENTIFIER .1.3.6.1.4.1.9.1.111.1.2.3 |
cat2600TsDmnTable SEQUENCE OF Cat2600TsDmnEntry .1.3.6.1.4.1.9.1.111.1.2.3.1 |
CAT2600-MIB Technical Reference Overview
The CAT2600-MIB SNMP MIB module published by Cisco defines 151 managed OID objects, including 113 scalar/column metrics, 10 SNMP tables, and 0 trap/notification events. Key tabular structures include cat2600TsTrapRcvrTable, cat2600TsPortTable, cat2600TsPortStnTable, cat2600TsOptPortStaTable, cat2600TsDmnTable, cat2600TsDmnStationTable.
Key OID Definitions in CAT2600-MIB
.1.3.6.1.4.1.9.1.111.1.2.1.1.14A table of managers to which to send traps. Entries in the table are saved across resets and power cycles.
.1.3.6.1.4.1.9.1.111.1.2.2.1A table of information about each port. The number of rows is given by cat2600TsNumPorts. (This value refers to PHYSICAL ports as opposed to internal logical CRF bridge ports.)
.1.3.6.1.4.1.9.1.111.1.2.2.3Port station table.
.1.3.6.1.4.1.9.1.111.1.2.2.2A table of station addresses known at an individual port. This table is designed to reduce the number of SNMP GETNEXT requests. This is done by packing many values into an octet string. (The maximum size frame should be used to return the result.) The instance returned for a GETNEXT is the value that identifies the last 'row' in the octet string. When the table is completely retrieved with one or more GETNEXTs, duplicate entries may be present, and entries may be skipped if the table is changing while being retrieved.
.1.3.6.1.4.1.9.1.111.1.2.3.1Currently active domains on the switch.
.1.3.6.1.4.1.9.1.111.1.2.3.5Stations seen in each domain.
.1.3.6.1.4.1.9.1.111.1.2.3.6A table of station addresses known at an individual port. This table is designed to reduce the number of SNMP GETNEXT requests. This is done by packing many values into an octet string. (The maximum size frame should be used to return the result.) The instance returned for a GETNEXT is the value that identifies the last 'row' in the octet string. When the table is completely retrieved with one or more GETNEXTs, duplicate entries may be present, and entries may be skipped if the table is changing while being retrieved.
.1.3.6.1.4.1.9.1.111.1.2.4.1The TokenPipe table.
.1.3.6.1.4.1.9.1.111.1.2.5.1Filters set up in the switch.
.1.3.6.1.4.1.9.1.111.1.2.6.1A table of the installed UFC cards in the switch. The number of entries in the table is given by cat2600TsNumberofUFCs.
.1.3.6.1.4.1.9.1.111.1.2.1.1.1The firmware version in the form major.minor. For port microcode (SOLO) version information see the mgmt.mib-2.interfaces.ifTable.ifEntry.ifDescr object.
.1.3.6.1.4.1.9.1.111.1.2.1.1.2The hardware version in the form major.minor.
.1.3.6.1.4.1.9.1.111.1.2.1.1.3System serial number.
.1.3.6.1.4.1.9.1.111.1.2.1.1.4Firmware installation date. This date is initially set by the Network Management station. Each time the NV RAM is cleared through the console this date needs to be set by the management station. This should be in the format YYYY MM DD HH MM SS.
.1.3.6.1.4.1.9.1.111.1.2.1.1.5Size in bytes of the binary firmware image.
.1.3.6.1.4.1.9.1.111.1.2.1.1.6Firmware binary image CRC value.
.1.3.6.1.4.1.9.1.111.1.2.1.1.7Firmware manufacturer.
.1.3.6.1.4.1.9.1.111.1.2.1.1.8IP address of the switch. Changes to this object take effect immediately.
.1.3.6.1.4.1.9.1.111.1.2.1.1.9IP subnet mask of the switch. Changes to this object take effect immediately.
.1.3.6.1.4.1.9.1.111.1.2.1.1.10IP default gateway used by the switch. Changes to this object take effect immediately.
.1.3.6.1.4.1.9.1.111.1.2.1.1.19This variable specifies the interval in seconds of sending ICMP Echo Requests to the default gateway. No PING packets will be sent if the value is set to 0. The default interval is 10 minutes.
.1.3.6.1.4.1.9.1.111.1.2.1.1.20Select the port to monitor traffic.
.1.3.6.1.4.1.9.1.111.1.2.1.1.21Allows the selection of the port that will be monitored by the port selected by cat2600TsTapPort.
.1.3.6.1.4.1.9.1.111.1.2.1.1.22Threshold for the switch to change to store and forward mode. A change in mode also generates a trap.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.