224
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

224 total
Object Name
alliedTelesyn
OBJECT IDENTIFIER
.1.3.6.1.4.1.207
products
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.1
bridge
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.1.1
atiBridgeagent
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.1.1.1
bridgesnmpd
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.1.1.1.1
atiBridge
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.1.1.1.1.1
repeater
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.1.2
intruderProtectionTrapThis trap is replaced by atiIntruderProtectionTrap starting from firmware ver 3.0. AT-3100 and TurboStack product families only. This trap is sent when an Intruder Alert occurs on a port due to a received packet with an unauthorized source MAC address. Intruder Protection for the module must be enabled. The varBind list contains the MAC address of the intruder.
TRAP-TYPE
.1.3.6.1.4.1.207.1.2.0.20
atiIntruderProtectionTrapAT-3100 and TurboStack product families only. This trap is sent when an Intruder Alert occurs on a module/port due to a received packet with an unauthorized source MAC address. Intruder Protection for the module must be enabled. The varBind list contains the module number, port number, and the MAC address of the intruder.
TRAP-TYPE
.1.3.6.1.4.1.207.1.2.0.21
atiRedundantPortChangeTrapTurboStack product family only. This trap is sent when ports, which are configured for redundant links, change from primary to secondary or secondary to primary.
TRAP-TYPE
.1.3.6.1.4.1.207.1.2.0.22
hub3600
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.1.2.1
hub3100
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.1.2.10
hubTurboStack
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.1.2.65
filterTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.2
ftConfigBridge FT operational parameters
SEQUENCE OF FtConfig
.1.3.6.1.4.1.207.2.1
ftMaxAgeSeconds before an unreferenced dynamic FT entry is removedro
INTEGER
.1.3.6.1.4.1.207.2.1.1
ftMaxRemoveMax number table entries removed each time table overflowsrw
INTEGER
.1.3.6.1.4.1.207.2.1.2
ftMaxFilterMax number FT entriesro
INTEGER
.1.3.6.1.4.1.207.2.1.3
ftAgeTimeSeconds between FT table entriesrw
INTEGER
.1.3.6.1.4.1.207.2.1.4
ftMaxPermMax number of permanent FT entries. May be set to zero which causes all non-system FT entries to be deletedrw
INTEGER
.1.3.6.1.4.1.207.2.1.5
ftForwMBcastFlag indicates if multicast (including broadcast) packets are to be forwarded (1) or discarded (0)rw
Enumeration
.1.3.6.1.4.1.207.2.1.6
ftSecureModeFlag indicates if bridge will learn addressesrw
Enumeration
.1.3.6.1.4.1.207.2.1.7
ftEntryBridge FT entries each selected by destination address
SEQUENCE OF FtEntry
.1.3.6.1.4.1.207.2.2
ftAgeFT entry age since last referenced in secondsro
INTEGER
.1.3.6.1.4.1.207.2.2.1
ftDispFT entry disposition. Can be more than one OR'ed togetherrw
Enumeration
.1.3.6.1.4.1.207.2.2.2
ftAddrdestination address (dummy index)
OCTET STRING
.1.3.6.1.4.1.207.2.2.91
interfaceErrorsSet of Ethernet link level errors
InterfaceErrors
.1.3.6.1.4.1.207.3
ifeInBusErrNumber of EtherStar read bus errors that have occurredro
Counter
.1.3.6.1.4.1.207.3.1
ifeInShortPktNumber of short packets receivedro
Counter
.1.3.6.1.4.1.207.3.2
ifeInAlgErrorNumber of packets received with alignment errorsro
Counter
.1.3.6.1.4.1.207.3.3
ifeInBadSizeNumber of packets received greater than 1518 bytesro
Counter
.1.3.6.1.4.1.207.3.4
ifeInOverflowNumber of times receive buffer overflowedro
Counter
.1.3.6.1.4.1.207.3.5
ifeInCRCErrNumber of CRC errors detectedro
Counter
.1.3.6.1.4.1.207.3.6
ifeOutColl16Number of packets discarded due to excessive collisionsro
Counter
.1.3.6.1.4.1.207.3.7
ifeOutColNumber of collisions detectedro
Counter
.1.3.6.1.4.1.207.3.8
ifeOutShortPktNumber of short packets transmittedro
Counter
.1.3.6.1.4.1.207.3.9
ifeOutUnderflowNumber of packets transmitted w/programmed length > buffered transmitted dataro
Counter
.1.3.6.1.4.1.207.3.10
ifeOutBusErrNumber of EtherStar write bus errorsro
Counter
.1.3.6.1.4.1.207.3.11
ifePort
Enumeration
.1.3.6.1.4.1.207.3.91
forwardCountersCounters associated with bridge entityro
ForwardCounters
.1.3.6.1.4.1.207.4
fcInOctetsNumber bytes received by bridge entity on specified portro
Counter
.1.3.6.1.4.1.207.4.1
fcInPktsNumber packets received by bridge entity on specified portro
Counter
.1.3.6.1.4.1.207.4.2
fcInNUcastPktsNumber multicast/broadcast packets received by bridge enity on specified portro
Counter
.1.3.6.1.4.1.207.4.3
fcForwOctetsNumber bytes forwarded by bridge entity onto specified portro
Counter
.1.3.6.1.4.1.207.4.4
fcForwPktsNumber of packets forwarded by bridge enity onto specified portro
Counter
.1.3.6.1.4.1.207.4.5
fcFiltOctetsNumber of bytes received on specified port that were discarded by bridge enityro
Counter
.1.3.6.1.4.1.207.4.6
fcFiltPktsNumber of packets dicarded by filtering by bridge enityro
Counter
.1.3.6.1.4.1.207.4.7
fcPort
INTEGER
.1.3.6.1.4.1.207.4.91
systemCountersSystem operating s/w countersro
SystemCounters
.1.3.6.1.4.1.207.5
sysMemFreeNumber of buffers of a particular size on the memory free listro
Counter
.1.3.6.1.4.1.207.5.1
sysMemAllocFailNumber of allocation failures for a particular buffer sizero
Counter
.1.3.6.1.4.1.207.5.2
sysMemTotAllocFailTotal number of memory allocation failuresro
Counter
.1.3.6.1.4.1.207.5.3
sysMemAllocTooBigNumber of memory allocation requests that failedro
Counter
.1.3.6.1.4.1.207.5.4
sysMemFreeFailNumber of memory free requests that failedro
Counter
.1.3.6.1.4.1.207.5.5
sysTimeToResetNumber of seconds unit bridge resetrw
Counter
.1.3.6.1.4.1.207.5.6
sysPanicMesgError message associated with last s/w generated resetro
OCTET STRING
.1.3.6.1.4.1.207.5.7
sysResetCountNumber of times bridge has been reset other than power on/offro
Counter
.1.3.6.1.4.1.207.5.8
spanningTree
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.6
stBridgeBridge specific parameters related to operation of Spanning Tree Protocol
SEQUENCE OF StBridge
.1.3.6.1.4.1.207.6.1
stBrNameComment string denoting the bridgerw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.207.6.1.1
stBrIdent802.1 Bridge IDro
OCTET STRING
.1.3.6.1.4.1.207.6.1.2
stBrMaxAge802.1 Max BPDU Age (sec) for bridgerw
INTEGER
.1.3.6.1.4.1.207.6.1.3
stBrHelloTime802.1 Hello Time (sec) for bridgerw
INTEGER
.1.3.6.1.4.1.207.6.1.4
stBrForwDelay802.1 Forward Delay Time (sec) for bridgerw
INTEGER
.1.3.6.1.4.1.207.6.1.5
stBrIsRootBridge is root (1=yes 0=no)ro
Enumeration
.1.3.6.1.4.1.207.6.1.6
stBrIsDesigFlag indicating status of bridge as designated bridge (1=yes 0=no)ro
Enumeration
.1.3.6.1.4.1.207.6.1.7
stBrSpanAddrMAC address used as Spanning Tree Protocol multicast addressro
OCTET STRING
.1.3.6.1.4.1.207.6.1.8
stBrPriority802.1 bridge priorityrw
INTEGER
.1.3.6.1.4.1.207.6.1.9
stBrSTPDisabledVariable to enable/disable operation of Spanning Tree (1=STP on 0=STP off)rw
Enumeration
.1.3.6.1.4.1.207.6.1.10
stRootParameters related to operation of Spanning Tree Protocol for Root bridge
SEQUENCE OF StRoot
.1.3.6.1.4.1.207.6.2
stRtIdent802.1 Bridge ID of current Root bridgero
OCTET STRING
.1.3.6.1.4.1.207.6.2.1
stRtCost802.1 Root Path Cost of current Root bridgero
INTEGER
.1.3.6.1.4.1.207.6.2.2
stRtPortPort number of port that provides path to current Root bridgero
Enumeration
.1.3.6.1.4.1.207.6.2.3
stRtMaxAge802.1 Max BPDU Age specified by current known Root bridgero
INTEGER
.1.3.6.1.4.1.207.6.2.4
stRtHelloTime802.1 Hello Time specified by current Root bridgero
INTEGER
.1.3.6.1.4.1.207.6.2.5
stRtForwDelay802.1 Forward Delay specified by current Root bridgero
INTEGER
.1.3.6.1.4.1.207.6.2.6
stPortPort specific parameters related to operation of Spanning Tree Protocol
SEQUENCE OF StPort
.1.3.6.1.4.1.207.6.3
stPrtState802.1 Port State disable and blocked statesrw
Enumeration
.1.3.6.1.4.1.207.6.3.1
stPrtCost802.1 Port Path Costrw
INTEGER
.1.3.6.1.4.1.207.6.3.2
stPrtIsDesigStatus of port as designated port for LANro
Enumeration
.1.3.6.1.4.1.207.6.3.3
stPrtIsRootStatus of port as Root Portro
Enumeration
.1.3.6.1.4.1.207.6.3.4
stPrtDesigRootBridge ID of Root brigdero
OCTET STRING
.1.3.6.1.4.1.207.6.3.5
stPrtDesigCostPath Cost to Root bridge as advertised by the designated bridgero
INTEGER
.1.3.6.1.4.1.207.6.3.6
stPrtDesigBridgeBridge ID of designated bridgero
INTEGER
.1.3.6.1.4.1.207.6.3.7
stPrtDesigPortPort ID of designated portro
INTEGER
.1.3.6.1.4.1.207.6.3.8
stPrtPriority802.1 Port Priorityrw
INTEGER
.1.3.6.1.4.1.207.6.3.9
stPrtPort
Enumeration
.1.3.6.1.4.1.207.6.3.91
spanTreeStatsSpanning Tree stats on countersro
SEQUENCE OF SpanTreeStats
.1.3.6.1.4.1.207.6.4
stsTopoChangesNumber of topology changes that have occured since power-onro
Counter
.1.3.6.1.4.1.207.6.4.1
stsConfigTimeoutNumber of timeouts due to config BPDU not receivedro
Counter
.1.3.6.1.4.1.207.6.4.2
stsPortDisableNumber of times port has been disabled since power-onro
Counter
.1.3.6.1.4.1.207.6.4.3
stsPortEnableNumber of times port has been enabled since power-onro
Counter
.1.3.6.1.4.1.207.6.4.4
stsInBadLenNumber of STP frames received with bad lenth by this portro
Counter
.1.3.6.1.4.1.207.6.4.5
stsInUnknownPackets received with bad 802.3 LSAP number by this portro
Counter
.1.3.6.1.4.1.207.6.4.6
stsIn8021ManPackets received with 802.1 Management LSAP (discarded)ro
Counter
.1.3.6.1.4.1.207.6.4.7
stsInConfigNumber of config BPDUs received by this portro
Counter
.1.3.6.1.4.1.207.6.4.8
stsOutConfigNumber of config BPDUs transmitted by this portro
Counter
.1.3.6.1.4.1.207.6.4.9
stsOutTopoChgNumber of Topology Change Notification BPDU transmitted by this portro
Counter
.1.3.6.1.4.1.207.6.4.10
stsPort
INTEGER
.1.3.6.1.4.1.207.6.4.91
filterRange
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.7
frNumRangeThe maximum number of filter range table entries when read (GET). Set to zero to delete all filter range table entries. A set with any other value is ignored.rw
INTEGER
.1.3.6.1.4.1.207.7.1
frEntryrw
SEQUENCE OF OCTET STRING
.1.3.6.1.4.1.207.7.2
frIndex
INTEGER
.1.3.6.1.4.1.207.7.91
mibObject
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.8
hubMib
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.8.1
rptrInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.8.1.1
actualIPAddrThe actual IP Address that is currently being used by the hub. This could be the same value as hubIPAddr, or it may be different if another IP Address was received via Bootp.ro
IpAddress
.1.3.6.1.4.1.207.8.1.1.1
hubIPAddrThe configured IP Address of the hub.rw
IpAddress
.1.3.6.1.4.1.207.8.1.1.2
subnetMaskSubnet mask of the hub.rw
IpAddress
.1.3.6.1.4.1.207.8.1.1.3
routerAddrGateway/router address of the hub.rw
IpAddress
.1.3.6.1.4.1.207.8.1.1.4
snmpManagerIP Address of the hub's SNMP manager to which Traps will be sent.rwdeprecated
IpAddress
.1.3.6.1.4.1.207.8.1.1.5
softwareProductThe ATI software product model number running in the hub.ro
DisplayString
.1.3.6.1.4.1.207.8.1.1.6
softwareLevelThe software release level running in the hub.ro
DisplayString
.1.3.6.1.4.1.207.8.1.1.7
configurationChangedA flag, set to the value changed(1) when any of the hub's status or configuration has been changed. When this object is read, then the value is reset to nochange(2).ro
Enumeration
.1.3.6.1.4.1.207.8.1.1.8
rptrNmMgrTableA list of SNMP Trap Manager stations Entries. The number of entries is given by the rptrNmMgrTotal mib object.
SEQUENCE OF RptrNmMgrEntry
.1.3.6.1.4.1.207.8.1.1.9
rptrNmMgrEntryAn Trap receipt Manager Entry containing ipaddress of the configured NMS's to which Traps are sent.
RptrNmMgrEntry
.1.3.6.1.4.1.207.8.1.1.9.1
rptrNmMgrIndexThe Index of SNMP Managers IP Address.ro
INTEGER
.1.3.6.1.4.1.207.8.1.1.9.1.1
rptrNmMgrIpAddrThe IP Address of the NMS host configured.rw
IpAddress
.1.3.6.1.4.1.207.8.1.1.9.1.2
deviceTableThe table contains the mapping of all devices in the chassis. For all hubs and switches, the object 'deviceQuadrant' returns 'right' (1). For docking devices, then it will reflect the position of the device in the docking station. This object is specific to Turbo Stack.
SEQUENCE OF DeviceEntry
.1.3.6.1.4.1.207.8.1.1.10
deviceEntryThe device entry in the DeviceTable.
DeviceEntry
.1.3.6.1.4.1.207.8.1.1.10.1
deviceIndexThe Slot number in the chassis where the device is installed.ro
INTEGER
.1.3.6.1.4.1.207.8.1.1.10.1.1
deviceQuadrantThe Quadrant of the device.ro
Enumeration
.1.3.6.1.4.1.207.8.1.1.10.1.2
deviceDescrTurboStack product family only. A textual description of the device. For devices that are repeaters, this value is identical to the rptrGroupDescr object.ro
DisplayString
.1.3.6.1.4.1.207.8.1.1.10.1.3
deviceObjectIDTurboStack product family only. The sysObject identification of the device. For devices that are repeaters, this value is identical to the rptrGroupObjectID object.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.8.1.1.10.1.4
deviceIpAddrTurboStack product family only. The IP address (if present) of the device. For hubs devices, this object will return the same value as hubIPAddr.ro
IpAddress
.1.3.6.1.4.1.207.8.1.1.10.1.5
devicePortCapacityTurboStack product family only. The number of ports contained within the device. Valid range is 1-1024. Within each device, the ports are uniquely numbered in the range from 1 to devicePortCapacity. For devices that are repeaters, this value is identical to the rptrGroupPortCapacity object.ro
INTEGER
.1.3.6.1.4.1.207.8.1.1.10.1.6
localOmegaStateThis object enables the Local Omega to be enabled or disabled.rw
Enumeration
.1.3.6.1.4.1.207.8.1.1.11
remoteOmegaStateThis object enables the Remote Omega to be enabled or disabled.rw
Enumeration
.1.3.6.1.4.1.207.8.1.1.12
groupInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.8.1.2
ledInfoSee groupLEDInforodeprecated
OCTET STRING
.1.3.6.1.4.1.207.8.1.2.1
groupInfoTableTable of group specific information.
SEQUENCE OF GroupInfoEntry
.1.3.6.1.4.1.207.8.1.2.2
groupInfoEntryAn entry in the table, containing information about a single group of ports.
GroupInfoEntry
.1.3.6.1.4.1.207.8.1.2.2.1
groupInfoIndexThis object identifies the group within the repeater for which this entry contains information.ro
INTEGER
.1.3.6.1.4.1.207.8.1.2.2.1.1
groupLEDInfoThis information encodes the current state of the module per-port LEDs.ro
OCTET STRING
.1.3.6.1.4.1.207.8.1.2.2.1.2
groupSegmentationAT-3100 product family only. This object controls the segmentation option for this group. It may be segmented, connected, or using the module's external segmentation switch.rw
Enumeration
.1.3.6.1.4.1.207.8.1.2.2.1.3
groupSecurityAT-3100 product family only. This object controls the Security option for this group. It may be enabled, disabled, or using module's external security switch.rw
Enumeration
.1.3.6.1.4.1.207.8.1.2.2.1.4
groupIntruderProtectionAT-3100 and TurboStack product families only. This object controls the Intruder Protection option for this group/module. For TurboStack products, disabled turns off Intruder Protection and places the module into source address Learning Mode. Enabled turns on Intruder Protection and places the module into Secure Mode.rw
Enumeration
.1.3.6.1.4.1.207.8.1.2.2.1.5
groupSrcAddrLearningModeAT-3100 product family only. This object indicates the Source Address Learning Mode. Mode1 : Automatic; passive devices: Automatic MAC address learning. Re-learn port MAC address after a port is disabled/re-enabled. Passive devices connected to a port will see all backbone traffic. Mode2 : Automatic; passive devices: Automatic MAC address learning. Re-learn port MAC address after link test fails (cable removed). Passive devices connected to a port will see all backbone traffic. Mode3 : Manual: No automatic MAC address learning (disabled). Mode4 : Automatic; active devices: Automatic MAC address learning. Re-learn port MAC address after a port is disabled/re-enabled. Passive devices connected to a port will see no backbone traffic.rw
Enumeration
.1.3.6.1.4.1.207.8.1.2.2.1.6
groupIntruderTrapAT-3100 and TurboStack product families only. This object controls the action to be taken by this group/module when an Intruder Alert event occurs. When this option is enabled, the detection of an intruder (a received packet with an unlearned or undefined source address) causes a Trap to be sent to the configured host manager. When this option is disabled then no Trap is sent on an Intruder Alert event.rw
Enumeration
.1.3.6.1.4.1.207.8.1.2.2.1.7
groupIntruderDisableAT-3100 and TurboStack product families only. This object controls the action to be taken by this group/module when an Intruder Alert event occurs. When this option is enabled, the detection of an intruder (a received packet with an unlearned or undefined source address) causes the port where the intruder was detected to be automatically disabled. When this option is disabled then the port will not be disabled on an Intruder Alert event.rw
Enumeration
.1.3.6.1.4.1.207.8.1.2.2.1.8
groupOperStatusTurboStack product family only. An object that indicates the operational status of the module. For modules that are repeaters, this value is identical to the rptrGroupOperStatus object. A status of operational(2) indicates that the module is present and functional within the chassis. A status of malfunctioning(3) indicates that the module is present within the chassis but is not functional. A status of notPresent(4) indicates that the module is temporarily or permanently physically and/or logically not a part of the chassis.ro
Enumeration
.1.3.6.1.4.1.207.8.1.2.2.1.9
groupDescrTurboStack product family only. A textual description of the module. For modules that are repeaters, this value is identical to the rptrGroupDescr object.ro
DisplayString
.1.3.6.1.4.1.207.8.1.2.2.1.10
groupObjectIDTurboStack product family only. The sysObject identification of the module. For modules that are repeaters, this value is identical to the rptrGroupObjectID object.rodeprecated
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.8.1.2.2.1.11
groupIPAddressTurboStack product family only. The IP address (if any) of the module. For modules that are repeaters, this value is identical to the actualIPAddr object. For non-repeater modules, this object identifies the IP address that may be used to communicate directly with the module.rodeprecated
IpAddress
.1.3.6.1.4.1.207.8.1.2.2.1.12
groupPortCapacityTurboStack product family only. The number of ports contained within the module. Valid range range is 1-1024. Within each module, the ports are uniquely numbered in the range from 1 to groupPortCapacity. For modules that are repeaters, this value is identical to the rptrGroupPortCapacity object.rodeprecated
INTEGER
.1.3.6.1.4.1.207.8.1.2.2.1.13
groupEraseSourceAddressTableTurboStack product family only. This object, when Set to the erase value, will clear (empty) the module Source Address Table, deleting all learned MAC addresses; this object will then automatically revert back to the noerase state. When Set to noerase, no action is taken and the Source Address Table remains unmodified. A Get of this object will always return the noerase value.rw
Enumeration
.1.3.6.1.4.1.207.8.1.2.2.1.14
groupAddSourceAddressTurboStack product family only. This object, when Set with a 48-bit MAC address value, will add the new MAC address to the module Source Address Table. A Get of this object will return a string of length zero.rw
OCTET STRING
.1.3.6.1.4.1.207.8.1.2.2.1.15
groupDeleteSourceAddressTurboStack product family only. This object, when Set with a 48-bit MAC address value, will delete the MAC address from the module Source Address Table. A Get of this object will return a string of length zero.rw
OCTET STRING
.1.3.6.1.4.1.207.8.1.2.2.1.16
groupLimitAddressPerPortTurboStack product family only. This object configures the module to allow no limitation on number of source addresses on its ports, or limit to only 1 source address per port.rw
Enumeration
.1.3.6.1.4.1.207.8.1.2.2.1.17
groupCheckPrimaryTimerTurboStack product family only. The Check Primary Timer is the timer value in seconds which determines how long to wait before checking if the primary port could receive again. This timer applies when the secondary port is enabled, and the primary port's failure is NOT due to loss of link. Range: 1 - 65535 in seconds, 0 means don't check receives. Default is 60 seconds.rw
INTEGER
.1.3.6.1.4.1.207.8.1.2.2.1.18
groupReceiveFailureTimerTurboStack product family only. The Receive Failure Timer is the timer value in seconds which determines how long to wait before the secondary port takes over when the primary port is not receiving data. This timer applies only when the primary port's failure is NOT due to loss of link. Range: 0 - 65535 in seconds, 0 means don't check receives. Default is 60 seconds.rw
INTEGER
.1.3.6.1.4.1.207.8.1.2.2.1.19
groupCheckResampleTimerTurboStack product family only. The Resample Timer is the timer value in milliseconds which determines how long to sample/test if the primary port could receive data or is no longer partitioned. This timer begins once groupCheckPrimaryTimer has expired, and during this sampling time, the secondary port cannot repeat data. Range: 100 - 65535 milliseconds. Default is 200 milliseconds.rw
INTEGER
.1.3.6.1.4.1.207.8.1.2.2.1.20
portInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.8.1.3
atiPortTableTable of descriptive and status information about the ports.
SEQUENCE OF AtiPortEntry
.1.3.6.1.4.1.207.8.1.3.1
atiPortEntryAn entry in the table, containing information about a single port.
AtiPortEntry
.1.3.6.1.4.1.207.8.1.3.1.1
atiPortGroupIndexThis object identifies the group containing the port for which this entry contains information.ro
INTEGER
.1.3.6.1.4.1.207.8.1.3.1.1.1
atiPortIndexThis object identifies the port within the group for which this entry contains information. This value can never be greater than rptrGroupPortCapacity for the associated group.ro
INTEGER
.1.3.6.1.4.1.207.8.1.3.1.1.2
portNamePort Namerw
DisplayString
.1.3.6.1.4.1.207.8.1.3.1.1.3
portStatePort State option: enabled allow repeating of packets through the port; disabled turns off the port and prevents packets repeating through the port.rw
Enumeration
.1.3.6.1.4.1.207.8.1.3.1.1.4
linkTestLink Test option: enabled turns on checking for link test signals for the port; disabled turns off checking for link test signals.rw
Enumeration
.1.3.6.1.4.1.207.8.1.3.1.1.5
altReconnectionReconnection Method: 1=IEEE Standard, 2=Alternate.rw
Enumeration
.1.3.6.1.4.1.207.8.1.3.1.1.6
polarityCorrectionPolarity Correction option: enabled turns on automatic polarity correction for the port; disabled turns off automatic polarity correction.rw
Enumeration
.1.3.6.1.4.1.207.8.1.3.1.1.7
partitionedLEDThis object reflects the current actual partitioning state of the port. The notpartitioned value means that the port is operational and repeating through the port is enabled. The partitioned value means that the port is not operational and repeating through the port is disabled.ro
Enumeration
.1.3.6.1.4.1.207.8.1.3.1.1.8
linkTestLEDThis object reflects the current actual link test state of the port. The nolinktesterror value means that valid link integrity test signals have been detected on the port, indicating that an operable device is cabled to the port. The linktesterror value means that no link integrity test signals have been detected, indicating removal or failure of the port-to-device cable, or that the device is not operational. This object applies only to UTP (twisted pair) and fiber optic ports (not AUI or BNC ports).ro
Enumeration
.1.3.6.1.4.1.207.8.1.3.1.1.9
polarityLEDThis object reflects the current actual polarity state of the port. The notreversed value means that the port-to-device cable connection is properly polarized. The reversed value means that the cable connection has reversed polarity. This object applies only to UTP (twisted pair) and fiber optic ports (not AUI or BNC ports).ro
Enumeration
.1.3.6.1.4.1.207.8.1.3.1.1.10
portMACAddressAT-3100 product family only. This object is either the MAC address of the last readable frame (i.e., counted by rptrMonitorPortReadableFrames) received by this port, or a manually input MAC address. If neither of those exists, then a string of length zero is returned. If a 'read' operation is performed on this object, the value it returns is the same as the value returned by object 'rptrAddrTrackNewLastSrcAddress' in the Standard Repeater MIB (RFC1516).rw
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.207.8.1.3.1.1.11
portFrames-64-127bytesTurboStack product family only. The number of readable frames received on this port where the frame length was in the range 64 through 127 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.3.1.1.12
portFrames-128-255bytesTurboStack product family only. The number of readable frames received on this port where the frame length was in the range 128 through 255 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.3.1.1.13
portFrames-256-511bytesTurboStack product family only. The number of readable frames received on this port where the frame length was in the range 256 through 511 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.3.1.1.14
portFrames-512-1023bytesTurboStack product family only. The number of readable frames received on this port where the frame length was in the range 512 through 1023 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.3.1.1.15
portFrames-1024-1518bytesTurboStack product family only. The number of readable frames received on this port where the frame length was in the range 1024 through 1518 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.3.1.1.16
portRedundantPortTurboStack product family only. This is the redundant port for atiPortIndex. If the port is a secondary port as indicated in portRedundantPosition, then it serves as a backup port. This would indicate paired ports with redundant link.rw
INTEGER
.1.3.6.1.4.1.207.8.1.3.1.1.17
portRedundantPositionTurboStack product family only. This object will retrieve the redundant position of the port, primary or secondary port, if the port has a redundant link to it.ro
Enumeration
.1.3.6.1.4.1.207.8.1.3.1.1.18
portLearningStateTurboStack product family only. This object enable the learning on a port to be shut ON or OFF. Once the learning is Shut Off, the learning of MAC Address will stop.rw
Enumeration
.1.3.6.1.4.1.207.8.1.3.1.1.19
rptrStat
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.8.1.4
hubReadableFramesThe sum total of the Readable Frames Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.1
hubReadableOctetsThe sum total of the Readable Octets (bytes) Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.2
hubFCSErrorThe sum total of the FCS (CRC) Error Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.3
hubAlignErrorThe sum total of the Alignment Error Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.4
hubFrameTooLongThe sum total of the Frame Too Long Error Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.5
hubShortEventThe sum total of the Short Event Error Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.6
hubRuntThe sum total of the Runt Error Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.7
hubLateEventThe sum total of the Late Event Error Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.8
hubVeryLongEventThe sum total of the Very Long Event Error (Jabber) Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.9
hubDataRateMismThe sum total of the Data Rate Mismatch Error Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.10
hubAutoPartitionThe sum total of the Auto Port Partition Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.11
hubTotalErrorThe sum total of all Error Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.12
hubPortCollisionThe sum total of the Port Collision Counters of all ports on all modules/groupsro
Counter
.1.3.6.1.4.1.207.8.1.4.13
hubFrames-64-127bytesTurboStack product family only. The sum total number of readable frames received on all ports on all modules/groups, where the frame length was in the range 64 through 127 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.4.14
hubFrames-128-255bytesTurboStack product family only. The sum total number of readable frames received on all ports on all modules/groups, where the frame length was in the range 128 through 255 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.4.15
hubFrames-256-511bytesTurboStack product family only. The sum total number of readable frames received on all ports on all modules/groups, where the frame length was in the range 256 through 511 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.4.16
hubFrames-512-1023bytesTurboStack product family only. The sum total number of readable frames received on all ports on all modules/groups, where the frame length was in the range 512 through 1023 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.4.17
hubFrames-1024-1518bytesTurboStack product family only. The sum total number of readable frames received on all ports on all modules/groups, where the frame length was in the range 1024 through 1518 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.4.18
groupStat
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.8.1.5
groupStatTableTable of performance and error statistics for the groups.
SEQUENCE OF GroupStatEntry
.1.3.6.1.4.1.207.8.1.5.1
groupStatEntryAn entry in the table, containing total performance and error statistics for a single group. Regular retrieval of the information in this table provides a means of tracking the performance and health of the networked devices attached to this group's ports. The counters in this table are redundant in the sense that they are the summations of information already available through other objects. However, these sums provide a considerable optimization of network management traffic over the otherwise necessary retrieval of the individual counters included in each sum.
GroupStatEntry
.1.3.6.1.4.1.207.8.1.5.1.1
groupStatIndexThis object identifies the group within the repeater for which this entry contains information.ro
INTEGER
.1.3.6.1.4.1.207.8.1.5.1.1.1
groupFCSErrorThe sum total of the FCS (CRC) Error Counters of all ports on this module/groupro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.2
groupAlignErrorThe sum total of the Alignment Error Counters of all ports on this module/groupro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.3
groupFrameTooLongThe sum total of the Frame Too Long Error Counters of all ports on this module/groupro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.4
groupShortEventThe sum total of the Short Event Error Counters of all ports on this module/groupro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.5
groupRuntThe sum total of the Runt Error Counters of all ports on this module/groupro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.6
groupPortCollisionThe sum total of the Port Collision Counters of all ports on this module/groupro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.7
groupLateEventThe sum total of the Late Event Error Counters of all ports on this module/groupro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.8
groupVeryLongEventThe sum total of the Very Long Event Error (Jabber) Counters of all ports on this module/groupro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.9
groupDataRateMismThe sum total of the Data Rate Mismatch Error Counters of all ports on this module/groupro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.10
groupAutoPartitionThe sum total of the Auto Port Partition Counters of all ports on this module/groupro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.11
groupFrames-64-127bytesTurboStack product family only. The sum total number of readable frames received on all ports on this module/group, where the frame length was in the range 64 through 127 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.12
groupFrames-128-255bytesTurboStack product family only. The sum total number of readable frames received on all ports on this module/group, where the frame length was in the range 128 through 255 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.13
groupFrames-256-511bytesTurboStack product family only. The sum total number of readable frames received on all ports on this module/group, where the frame length was in the range 256 through 511 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.14
groupFrames-512-1023bytesTurboStack product family only. The sum total number of readable frames received on all ports on this module/group, where the frame length was in the range 512 through 1023 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.15
groupFrames-1024-1518bytesTurboStack product family only. The sum total number of readable frames received on all ports on this module/group, where the frame length was in the range 1024 through 1518 octets.ro
Counter
.1.3.6.1.4.1.207.8.1.5.1.1.16
groupSAT
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.8.1.6
groupSourceAddressTableTurboStack product family only. Table of learned and/or configured source MAC addresses which defines the only valid and allowable source addresses for this module (if Intruder Protection is enabled).
SEQUENCE OF GroupSATEntry
.1.3.6.1.4.1.207.8.1.6.1
groupSATEntryTurboStack product family only. An entry in the Source Address Table, containing information about a single source MAC address.
GroupSATEntry
.1.3.6.1.4.1.207.8.1.6.1.1
groupSATModuleTurboStack product family only. This object identifies the group within the repeater for which this entry contains information.ro
INTEGER
.1.3.6.1.4.1.207.8.1.6.1.1.1
groupSATIndexTurboStack product family only. This object identifies the index within the Source Address Table for which this entry contains information.ro
INTEGER
.1.3.6.1.4.1.207.8.1.6.1.1.2
groupSATMacAddressTurboStack product family only. This object is the learned or configured source MAC address. If no MAC address has been learned for this table entry (if this is beyond the logical end of the table) then a string of zero length will be returned.ro
OCTET STRING
.1.3.6.1.4.1.207.8.1.6.1.1.3
groupSATPortTurboStack product family only. This object is the port number where the source MAC address was last detected. If the MAC address has not been detected since the system was last started, then this object will be zero.ro
INTEGER
.1.3.6.1.4.1.207.8.1.6.1.1.4
atiTrapAttrs
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.9
atiTrapIntruderMacAddressThe Mac address of the Intruder which is different from the rfc1516 object rptrAddrTrackLastSourceAddress is seen on port which is the the next object
OCTET STRING
.1.3.6.1.4.1.207.9.1
atiTrapIntruderModuleNumberThis is the module number on which an intruder was seen.
INTEGER
.1.3.6.1.4.1.207.9.2
atiTrapIntruderPortNumberThis is the port number on which an intruder was seen.
INTEGER
.1.3.6.1.4.1.207.9.3
atiPortChangeDirectionThis is the direction of redundant port change. These two values are used in the trap atiRedundantPortChangeTrap.
Enumeration
.1.3.6.1.4.1.207.9.4