Home/Catalog/ASCEND-MIBCLTM-MIB

ASCEND-MIBCLTM-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ASCEND-MIBCLTM-MIB.

51
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

51 total
Object Name
mibcltmCmd
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.66
RFC1155-SMI
Unknown
.1.3.6.1.4.1.4253.1.66
mibcltmCmdTableA list of mibcltmCmd profile entries.
SEQUENCE OF MibcltmCmdEntry
.1.3.6.1.4.1.4253.1.66.1
mibcltmCmdEntryA mibcltmCmd entry containing objects that maps to the parameters of mibcltmCmd profile.
MibcltmCmdEntry
.1.3.6.1.4.1.4253.1.66.1.1
cltmCmd-Index-oro
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.1
cltmCmd-CltmSlotIdentify the CLTM slot within the system.ro
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.2
cltmCmd-TestTimeStampValue of the sysUpTime when the last test command was issued. This parameter is cleared when any of the test parameters are changed.ro
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.3
cltmCmd-TestSequenceSequence of the last issued test command.ro
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.4
cltmCmd-TestOperationThe current operation that is active on the CLT Module. Defaultls to 'none'. Set to 'none' to stop the test procedure.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.5
cltmCmd-DmmTypeDMM Measurement Type.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.6
cltmCmd-DmmLeadDMM Measurement Leads.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.7
cltmCmd-BackgroundNoiseFilterLine Filter Type for Background Noise Test.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.8
cltmCmd-BackgroundNoiseTerminationLine Termination Type for Background Noise Test.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.9
cltmCmd-LoopResistanceUnitMeasurement System for Loop Resistance Test.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.10
cltmCmd-LoopResistanceTempLine Temperature for Loop Resistance Test. Assigned in degree celsius/fahrenheit.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.11
cltmCmd-ImpulseNoiseStartThreshThreshold for Impulse Noise Test. The Range is 50-100 dBrm.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.12
cltmCmd-ImpulseNoiseStartDeltaDelta Value for Impulse Noise Test. The delta range is 2-6 dBrw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.13
cltmCmd-ImpulseNoiseStartMaxCountMax Count for Impulse Noise Test. The range of the value is 1-1999.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.14
cltmCmd-ImpulseNoiseStartDeadTimeDead Time Value for Impulse Noise Start Test. The value is assigned in 0.1 ms increments.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.15
cltmCmd-ImpulseNoiseStartTimerTimer values for Impulse Noise Start Test. The value is assigned in 1 minute increment.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.16
cltmCmd-CalibrationTypeCalibration Typerw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.17
cltmCmd-ToneSendFreqTone Send Frequency in KHz.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.18
cltmCmd-ToneSendLevelTone Send Level in dBm.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.19
cltmCmd-ToneSendPeriodAmount of time a tone is sent (1-20 Minutes).rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.20
cltmCmd-TdrUnitMeasurement System for TDR Test.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.21
cltmCmd-TdrGaugeTDR gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.22
cltmCmd-TdrVpTDR VP as percentage of the speed of light.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.23
cltmCmd-TdrAvgNumber of trials to get the avarage.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.24
cltmCmd-TdrGetTypeTDR Test Range Measurement Type. If set to automatic cltmCmdTdrStartLen and cltmCmdTdrMeasureLen do not need to be set.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.25
cltmCmd-TdrStartDistanceTDR Start Length for MANUAL mode, the value is given in feet (15..20000) for the English system and cm (460..609750) for the metric system.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.26
cltmCmd-TdrMeasurementLengthTDR Measurement Length for MANUAL mode, the value is given in feet (300..20000) for the English system and cm (9150..609750) for the metric system.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.27
cltmCmd-DmmdcdPeriodAmount of time measurement is made (0,1-5 100ms;0=MAX).rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.28
cltmCmd-DmmdcdVoltageTest voltage to be used (-230 to 230 Volts).rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.29
cltmCmd-DmmdcdImpedanceOutput Impedance to be used (10 to 1000 Kohms).rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.30
cltmCmd-DmmcapPeriodAmount of time measurement is made (0,1-5 100ms;0=MAX).rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.31
cltmCmd-DmmallTypeDMM Measurement Type.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.32
cltmCmd-DmmallPeriodAmount of time measurement is made (0,1-5 100ms;0=MAX).rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.33
cltmCmd-DmmallInputImpInput Impedance (100, 1000 Kohm).rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.34
cltmCmd-CtoneTypeControl tone, type of DSL service (ADSL, GLITE).rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.35
cltmCmd-CtoneToneControl tone, type of Tone (QUIET, RESTORE).rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.36
cltmCmd-TtoneLeadtrace tone, Measurement Leads.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.37
cltmCmd-TtoneLeveltrace tone, Tone Send Level in dBm.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.38
cltmCmd-TtonePeriodtrace tone, Amount of time a tone is sent (1-20 Minutes).rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.39
cltmCmd-BtapStartLengthMeasurement start length (15 - 20000 ft. or 5 - 6097 meter).rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.40
cltmCmd-BtapMeasureLengthMeasurement length (100 - 20000 ft. or 32 - 6097 meter).rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.41
cltmCmd-Action-orw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.42
cltmCmd-FcllocUnitMeasurement System for FCLLOC Test.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.43
cltmCmd-FcllocGaugeFCLLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.44
cltmCmd-ShortlocUnitMeasurement System for SHORTLOC Test.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.45
cltmCmd-ShortlocGaugeSHORTLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.rw
INTEGER
.1.3.6.1.4.1.4253.1.66.1.1.46
cltmCmd-ShortlocTypeSHORTLOC test type.rw
Enumeration
.1.3.6.1.4.1.4253.1.66.1.1.47