Home/Catalog/LUXN-MIB

LUXN-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for LUXN-MIB.

3302
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

3302 total
Object Name
luxN
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253
RFC1213-MIB
Unknown
.1.3.6.1.4.1.4253
luxNGenericTrapThis is a generic trap identifying an event for a given event source. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1
luxNVoadmDetectorFailureTrapThis trap is sent when a failure is detected on the VOADM power monitor. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1001
luxNVoadmDetectorFailureResolvedTrapThis trap is sent when a failure on the VOADM power monitor has been resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1002
luxNVoadmOutofRangeTrapThis trap is sent when the user configured settings for a VOADM would force the power levels to be outside of allowed operating ranges for the current link conditions. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1003
luxNVoadmOutofRangeResolvedTrapThis trap is sent when an existing VOADM out of range condition is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1004
luxNsignalStrengthHighTrapThis trap is sent when the receieve signal strength is high. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1005
luxNsignalStrengthLowTrapThis trap is sent when the receieve signal strength is low. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1006
luxNsignalStrengthNormalTrapThis trap is sent when the receieve signal strength is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1007
luxNlaserPowerOutOfRangeTrapThis trap is sent upon detection of out of range laser power. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1008
luxNlaserPowerNormalTrapThis trap is sent upon detection of normal laser power. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1009
luxNberHighThresholdExceededThis trap is sent upon detecting that MCMESC's BER high threshold is exceeds. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1010
luxNberHighThresholdExceededNormalThis trap is sent upon detecting that MCMESC's BER high threshold is not exceeded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1011
luxNberModerateThresholdExceededThis trap is sent upon detecting that MCMESC's BER moderate threshold is exceeded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1012
luxNberModerateThresholdExceededNormalThis trap is sent upon detecting that MCMESC's BER moderate threshold is not exceeded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.1013
luxNSNMPKeepaliveThis trap is sent out periodicly by the MPM when SNMP keep alive functionality is enabled.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2000
luxNSNMPKeepalivesEnabledThis trap is sent upon SNMP keep alive functionality being enabled
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2001
luxNSNMPKeepalivesDisabledThis trap is sent upon SNMP keep alive functionality being disabled
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2002
luxNSNMPKeepaliveIntervalChangedThis trap is sent when the SNMP keep alive interval is modified
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2003
luxNTelnetClientEnabledTelnet client has been enabled for active telnet sessions
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2004
luxNTelnetClientDisabledTelnet client has been disabled for active telnet sessions
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2005
luxNsnmpAuthenticationFailureTrapThis trap is sent upon receipt of invalid community strings. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2017
luxNcoldStartTrapThis trap is sent when the device has reinitialized itself. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2018
luxNwarmStartTrapThis trap is sent when the device has undergone a warm boot. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2019
luxNlossOfLightResolvedTrapThis trap is sent when a loss of light condition has been resolved. For OCM/MCMT1/MCME1, it indicates that the link between two optically connected channel cards is up. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2021
luxNlossOfLightDetectedTrapThis trap is sent when a loss of light condition has been detected. For OCM/MCMT1/MCME1, it indicates that the link between two optically connected channel cards is down. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2022
luxNntpEnableTrapThis trap is sent when NTP is enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2023
luxNntpDisableTrapThis trap is sent when NTP is disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2024
luxNntpTimeServerChangedTrapThis trap is sent when the NTP time server is changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2025
luxNntpUpdateIntervalChangedTrapThis trap is sent when the NTP update interval is changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2026
luxNtimeZoneChangedTrapThis trap is sent when the system time zone is changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2027
luxNspiConnectionUpTrapObsolete. This trap is sent when SPI communications has been established with a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2030
luxNcardLostTrapThis trap is sent when SPI communications has been lost with a card specified in the source field. The reason is either that the card has been physically removed or there exist a failure condition. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2031
luxNConfigChangeTrapThis trap is sent when a configuration change has ocurred for a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2034
luxNstatsPollFailedTrapThis trap is sent when statistics data can no longer be gathered from a card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2035
luxNCardFoundTrapThis trap is sent when a card has been discovered in the chassis. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2040
luxNlocalLoopbackEnabledTrapThis trap is sent when the local loopback mode has been enabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2041
luxNremoteLoopbackEnabledTrapThis trap is sent when the remote loopback mode has been enabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2042
luxNlocalLoopbackDisabledTrapThis trap is sent when the local loopback mode has been disabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2043
luxNremoteLoopbackDisabledTrapThis trap is sent when the remote loopback mode has been disabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2044
luxNftpSessionInitiatedTrapThis trap is sent when a ftp session has been initiated from the CLI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2047
luxNuserResetStatusTrapObsolete. This trap is sent when the status information for a card specified in the source field has been modified via the snmp agent. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2050
luxNprotectionSwitchTrapThis trap is sent when a protection switch has occurred either automatically or manually. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2051
luxNipAddressErrorTrapObsolete. This trap is sent when an error has occurred while configuring the IP address. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2052
luxNipNetmaskErrorTrapObsolete. This trap is sent when an error has occurred while configuring the Netmask. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2053
luxNdefaultGatewayErrorTrapObsolete. This trap is sent when an error has occurred while configuring the default gateway. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2054
luxNlossOfSignalTrapThis trap is sent when a loss of signal is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2055
luxNlossOfSignalNormalTrapThis trap is sent when a loss of signal problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2056
luxNlossOfFrameTrapThis trap is sent when a loss of frame error condition is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2057
luxNlossOfFrameNormalTrapThis trap is sent when a loss of frame error condition on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2058
luxNrecvAISTrapThis trap is sent when a receive AIS (Alarm Indication Signal) is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2059
luxNrecvAISNormalTrapThis trap is sent when a receive AIS (Alarm Indication Signal) problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2060
luxNrecvYellowAlarmTrapThis trap is sent when a receive receive yellow alarm is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2061
luxNrecvYellowAlarmNormalTrapThis trap is sent when a receive receive yellow alarm problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2062
luxNlineCodeViolationTrapThis trap is sent when a line code violation error condition is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2063
luxNlineCodeViolationNormalTrapThis trap is sent when a line code violation error condition on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2064
luxNframingAlarmTrapThis trap is sent when a framing alarm is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2065
luxNframingAlarmNormalTrapThis trap is sent when a framing alarm problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2066
luxNlossOfTimingTrapThis trap is sent when a loss of timing condition is detected on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2067
luxNlossOfTimingNormalTrapThis trap is sent when a loss of timing problem on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2068
luxNselfTestFailTrapThis trap is sent when a self-test failure is detected on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2073
luxNselfTestPassTrapThis trap is sent when a successful self-test is detected on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2074
luxNIbmDownTrapThis trap is sent when a problem is detected on a inband management link. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2075
luxNIbmNormalTrapThis trap is sent when a problem is resolved on a inband management link. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2076
luxNnearendCardLoopbackEnabledTrapThis trap is sent to indicate that a near-end card loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2077
luxNnearendCardLoopbackDisabledTrapThis trap is sent to indicate that a near-end card loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2078
luxNnetworkPortLoopbackEnabledTrapThis trap is sent to indicate that a network port loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2079
luxNnetworkPortLoopbackDisabledTrapThis trap is sent to indicate that a network port loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2080
luxNnetworkCardLoopbackEnabledTrapThis trap is sent to indicate that a network card loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2081
luxNnetworkCardLoopbackDisabledTrapThis trap is sent to indicate that a network card loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2082
luxNnearendPortLoopbackEnabledTrapThis trap is sent to indicate that a nearend port loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2083
luxNnearendPortLoopbackDisabledTrapThis trap is sent to indicate that a nearend port loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2084
luxNpowerSupplyNotPresentTrapThis trap is sent to indicate that the power supply specified in the source field is not present. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2085
luxNpowerSupplyOKTrapThis trap is sent to indicate that the power supply specified in the source field is performing properly. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2086
luxNpowerSupplyDegradedTrapThis trap is sent to indicate that the performance of the power supply specified in the source field has degraded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2087
luxNpowerSupplyFailureTrapThis trap is sent to indicate that the power supply specified in the source field has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2088
luxNfanOKTrapThis trap is sent to indicate that the fan specified in the source field is performing properly. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2089
luxNfanFailureTrapThis trap is sent to indicate that the fan specified in the source field has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2090
luxNcsimDataUnavailableTrapThis trap is sent to indicate that the ColorSIM module as specified in the source field is in a Data Unavailable state. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2091
luxNcsimDataAvailableTrapThis trap is sent to indicate that the ColorSIM module as specified in the source field is in a Data Available state. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2092
luxNcsimModuleFailureTrapThis trap is sent to indicate that the ColorSIM module as specified in the source field has failed to operate properly. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2093
luxNethernetLossOfCarrierTrapThis trap is sent to indicate that loss of carrier has been detected on the CPE's ethernet port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2094
luxNethernetCarrierDetectedTrapThis trap is sent to indicate that the carrier has been detected on the CPE's ethernet port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2095
luxNtimingPriorityChangedTrapThis trap is sent to indicate that the timing priority for a card has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2096
luxNopenFiberCPEAlarmTrapThis trap is sent when an open fiber condition on the CPE has been detected from a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2097
luxNopenFiberCPEAlarmResolvedTrapThis trap is sent when an open fiber condition on the CPE has been resolved from a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2098
luxNstandbyMPMDetectedTrapThis trap is sent when the standby MPM card has been detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2099
luxNstandbyMPMLostTrapThis trap is sent when the standby MPM card has been lost. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2100
luxNprotectionLinkFailureTrapThis trap is sent when the protection link has become unaviable due to either low receive power level or an open fiber condition. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2101
luxNprotectionLinkFailureResolvedTrapThis trap is sent when the protection link has become available as a result of a corrective action to resolve a previous failure condition. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2102
luxNtopologyDatabaseChangedTrapThis trap is sent whenever a link has either been added or deleted from the topology database. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2103
luxNredundantDatabaseCopyCompleteThis trap is sent upon completion of a forced redundant database copy. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2104
luxNredundantDatabaseCopyFailedThis trap is sent when a failure occurs during a forced redundant database copy. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2105
luxNimageExportInProgressTrapThis trap is sent when an module image is being exported from the MPM through ftp. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2106
luxNimageExportSuccessTrapThis trap is sent when a module image exported from the MPM through ftp has been completed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2107
luxNimageExportFailedTrapThis trap is sent when a module image exported from the MPM through ftp has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2108
luxNunknownCardTypeDetectedTrapThis trap is sent when a module with an unknown card type is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2109
luxNosamBiasCurrentOverLimitTrapThis trap is sent when the osam's bias current exceeds 90% of allowed maximum. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2110
luxNosamBiasCurrentNormalThis trap is sent when the osam's bias current is within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2111
luxNosamTecCurrentOverLimitThis trap is sent when the osam's TEC current is above the specified limit. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2112
luxNosamTecCurrentNormalThis trap is sent when the osam's TEC current is within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2113
luxNosamLaserTemperatureDriftThis trap is sent when the osam's laser temperature drifts by more than +/- 2 degree Celsius. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2114
luxNosamLaserTemperatureStableThis trap is sent when the osam's laser temperature no longer drifts. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2115
luxNosamMaxInputPowerReachedThis trap is sent when the osam's input power is greater than or equal to 9 dBm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2116
luxNosamInputPowerBackDownNormalThis trap is sent when the osam's input power has fallen within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2117
luxNosamMaxOutputPowerReachedThis trap is sent when the osam's output power is greater than or equal to 13 dBm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2118
luxNosamOutputPowerNormalThis trap is sent when the osam's output power is within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2119
luxNosamOpticalGainDeltaExceededThis trap is sent when the osam's gain delta is greater than or equal to 4 dB. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2120
luxNosamOpticalGainDeltaNormalThis trap is sent when the osam's gain delta is less than 4 dB. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2121
luxNosamMinInputPowerBelowLimitThis trap is sent when the osam's input power is less than or equal to -30 dBm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2122
luxNosamInputPowerBackUpNormalThis trap is sent when the osam's input power has risen within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2123
luxNosamSingleAprSensorFailedThis trap is sent when the osam's APR sensor is not functioning. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2124
luxNosamSingleAprSensorNormalThis trap is sent when the osam's APR sensor has become functional. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2125
luxNosamDualAprSensorFailedThis trap is sent when both of the osam's APR sensors are not functioning. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2126
luxNosamDualAprSensorNormalThis trap is sent when both of the osam's APR sensors has become functional. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2127
luxNosamFiberDisconnectedThis trap is sent when a fiber disconnect condition has been detected on an osam module. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2128
luxNosamFiberConnectedThis trap is sent when a fiber connect condition has been detected after a fiber disconnect on an osam module. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2129
luxNosamControlChangedThis trap is sent when either the current control or gain control has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2130
luxNosamLaserModuleOnThis trap is sent when the laser module has been turned on by the osam firmware. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2131
luxNosamLaserModuleOffThis trap is sent when the laser module has been turned off by the osam firmware. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2132
luxNipAuthenticationFailureNot yet supported. This trap is sent when access from an invalid IP address based on the ACL has been detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2133
luxNftpCompletedTrapThis trap is sent when the ftp session has been disconnected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2134
luxNftpHostFailedTrapThis trap is sent when the MPM is unable to connect to the ftp host. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2135
luxNimageUpdateInProgressTrapThis trap is sent when an module image is being downloaded to MPM through ftp. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2136
luxNimageUpdateSuccessTrapThis trap is sent when a module image download to MPM through ftp has been completed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2137
luxNimageUpdateFailedTrapThis trap is sent when a module image download to MPM through ftp has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2138
luxNmoduleUpdateInProgressTrapThis trap is sent when a module image is being transferred from the MPM to the module. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2139
luxNmoduleUpdateSuccessTrapThis trap is sent when a module image transfer from the MPM to the module has been completed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2140
luxNmoduleUpdateFailedTrapThis trap is sent when a module image transfer from the MPM to the module has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2141
luxNethernetLinkFailureThis trap is sent upon detection of the ethernet link failure on the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2142
luxNethernetLinkFailureResolvedThis trap is sent upon resolution of the ethernet link failure on the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2143
luxNfanNotPresentTrapThis trap is sent to indicate that the fan specified in the source field is not present in the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2144
luxNcardMismatchTrapThis trap is sent when a card mismatch is found in a given slot. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2145
luxNpwrFeedLowVoltageTrapThis trap is sent when the DC voltage level on the power feed reaches very close to the shutdown voltage. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2146
luxNpwrFeedLowVoltageRecoveryTrapThis trap is sent when the DC voltage level on the power feed recovers from the low voltage level condition . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2147
luxNpwrFeedOKTrapThis trap is sent when the DC voltage level on the power feed is within the operating window of the chassis . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2148
luxNpwrFeedFailureTrapThis trap is sent when the DC voltage level on the power feed is either too low or too high to operate the chassis The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2149
luxNpwrFeedBrkOpenTrapThis trap is sent when a user manually flips open the breaker relay switch attached to that feed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2150
luxNextCritAlmInpTrapThis trap is sent when an alarm gets generated at an external alarm input that is configured for critical severity. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2151
luxNextMajAlmInpTrapThis trap is sent when an alarm gets generated at an external alarm input that is configured for majority severity. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2152
luxNextMinorAlmInpTrapThis trap is sent when an alarm gets generated at an external alarm input that is configured for minor severity. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2153
luxNextClearAlmInpTrapThis trap is sent when an alarm gets cleared at an external alarm input. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2154
luxNpwrFeedOverVoltageTrapThis trap is sent when the DC voltage level on the power feed reaches very close to the shutdown voltage on the higher side. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2155
luxNpwrFeedOverVoltageRecoveryTrapThis trap is sent when the DC voltage level on the power feed recovers from the over voltage level condition . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2156
luxNstandbySWMismatchTrapThis trap is sent when there is a mismatch between the software version of standby and active MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2157
luxNstandbyDBNotSupportedTrapThis trap is sent when the standby MPM do not support Active MPM's database. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2158
luxNactiveStandbySWAlignedTrapThis trap is sent when the software version between standby and active MPM is aligned. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2159
luxNactiveStandbyDBAlignedTrapThis trap is sent when the database version between standby and active MPM is aligned. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2160
luxNmcmescTestSequenceOnTrapThis trap is sent when the test-sequence is set to ON on an MCMESC card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2161
luxNmcmescTestSequenceOffTrapThis trap is sent when the test-sequence is set to OFF on an MCMESC card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2162
luxNselfTestStartedTrapThis trap is sent when self-test has started for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2163
luxNselfTestEndedTrapThis trap is sent when self-test has ended for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2164
luxNvoadmMuxSetPointOutOfRangeThis trap is sent when a VOADM module has detected that the recently configured mux set point value would bring down the fibre if applied. The set point value is rejected and the MPM and module returns to the previously configured mux set point. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2165
luxNvoadmDemuxForceConfigThis trap is sent when a VOADM module forces its Demux configuration into fixed power mode. Forcing the Demux mode to fixed power mode can only occur when the Demux ports are configured for fixed attentuation mode and network conditions change sufficently that the current configuration may cause damage to the laser. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2166
luxNSfpNotPresentThis trap is sent when a missing SFP is detect. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2167
luxNSfpPresentThis trap is sent when a SFP has been inserted into the module .The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2168
luxNSfpFailureThis trap is sent when a SFP failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2169
luxNSfpFailureResolvedThis trap is sent when a SFP failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2170
luxNSfpNotAuthorizedThis trap is sent when an unauthorized SFP is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2171
luxNSfpAuthorizedThis trap is sent when an unauthorized SFP is replaced with an authorized SFP. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2172
luxNSfpRateMismatchThis trap is sent when a SFP does not supported the user configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2173
luxNSfpRateMismatchResolvedThis trap is sent when a SFP that does not support the user configured line rate is replaced with an SFP that does. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2174
luxNLinkRxSignalDegradedThis trap is sent when the packet error rate increases over 10e-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2175
luxNLinkRxSignalDegradedResolvedThis trap is sent when the packet error rate falls below 10e-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2176
luxNLinkTxFaultThis trap is sent when a Tx fault is detect on the link port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2177
luxNLinkTxFaultResolvedThis trap is sent when a Tx fault is resolved on the link port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2178
luxNPortTxFaultThis trap is sent when a Tx fault is detect on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2179
luxNPortTxFaultResolvedThis trap is sent when a Tx fault is resolved on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2180
luxNXfpNotPresentThis trap is sent when a missing XFP is detect. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2181
luxNXfpPresentThis trap is sent when a XFP has been inserted into the module .The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2182
luxNXfpFailureThis trap is sent when a XFP failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2183
luxNXfpFailureResolvedThis trap is sent when a XFP failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2184
luxNXfpNotAuthorizedThis trap is sent when an unauthorized XFP is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2185
luxNXfpAuthorizedThis trap is sent when an unauthorized XFP is replaced with an authorized XFP. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2186
luxNXfpRateMismatchThis trap is sent when a XFP does not supported the user configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2187
luxNXfpRateMismatchResolvedThis trap is sent when a XFP that does not support the user configured line rate is replaced with a XFP that does. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2188
luxNCpeXfpNotPresentThis trap is sent when a missing XFP is detect for a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2189
luxNCpeXfpPresentThis trap is sent when a XFP has been inserted into the module CPE port.The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2190
luxNCpeXfpFailureThis trap is sent when a CPE XFP failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2191
luxNCpeXfpFailureResolvedThis trap is sent when a CPE XFP failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2192
luxNCpeXfpNotAuthorizedThis trap is sent when an unauthorized XFP is detected in a CPE prot. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2193
luxNCpeXfpAuthorizedThis trap is sent when an unauthorized XFP is replaced with an authorized XFP in a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2194
luxNCpeXfpRateMismatchThis trap is sent when a CPE XFP does not supported the user configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2195
luxNCpeXfpRateMismatchResolvedThis trap is sent when a CPE XFP that does not support the user configured line rate is replaced with an XFP that does. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2196
luxNOutOfFrameThis trap is sent when an out of frame error is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2197
luxNOutOfFrameResolvedThis trap is sent when an out of frame error is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2198
luxNCpeLossOfFrameThis trap is sent when a loss of frame error is detected on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2199
luxNCpeLossOfFrameResolvedThis trap is sent when a loss of frame error is resolved on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2200
luxNCpeOutOfFrameThis trap is sent when an out of frame error is detected on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2201
luxNCpeOutOfFrameResolvedThis trap is sent when an out of frame error is resolved on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2202
luxNCdrFailureThis trap is sent when a CDR failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2203
luxNCdrFailureResolvedThis trap is sent when a CDR failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2204
luxNBitError10Em3This trap is sent when the modules bit error rate exceeds 10E-3. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2205
luxNBitError10Em3ResolvedThis trap is sent when the modules bit error rate falls below 10E-3. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2206
luxNBitError10Em4This trap is sent when the modules bit error rate exceeds 10E-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2207
luxNBitError10Em4ResolvedThis trap is sent when the modules bit error rate falls below 10E-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2208
luxNBitError10Em6This trap is sent when the modules bit error rate exceeds 10E-6. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2209
luxNBitError10Em6ResolvedThis trap is sent when the modules bit error rate falls below 10E-6. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2210
luxNBitError10Em7This trap is sent when the modules bit error rate exceeds 10E-7. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2211
luxNBitError10Em7ResolvedThis trap is sent when the modules bit error rate falls below 10E-7. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2212
luxNAisReceivedThis trap is sent when AIS-L is received on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2213
luxNAisReceivedResolvedThis trap is sent when AIS-L is no longer received on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2214
luxNAisTransmittedThis trap is sent when starts transmitting on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2215
luxNAisTransmittedResolvedThis trap is sent when is no longer transmitting on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2216
luxNcaseTemperatureHiTrapThis trap is sent when case temperature is HI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2225
luxNcaseTemperatureNormalTrapThis trap is sent when case temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2226
luxNcaseTemperatureLoTrapThis trap is sent when case temperature is LO. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2227
luxNcaseTemperatureLoNormalTrapThis trap is sent when case temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2228
luxNpumpTemperatureHiTrapThis trap is sent when pump temperature is HI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2229
luxNpumpTemperatureNormalTrapThis trap is sent when pump temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2230
luxNcoilTemperatureHiTrapThis trap is sent when coil temperature is HI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2231
luxNcoilTemperatureNormalTrapThis trap is sent when coil temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2232
luxNlossOutputPowerTrapThis trap is sent when loss of output power (or gain) is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2233
luxNlossOutputPowerNormalTrapThis trap is sent when loss of output power (or gain) is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2234
luxNreflectedOutputPowerHiTrapThis trap is sent when excessive reflected output power is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2235
luxNreflectedOutputPowerNormalTrapThis trap is sent when reflected output power is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.2236
luxNlineRateNotSuppotedThis trap is sent to indicate that the module hardware does not support the configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3001
luxNmpmBootImageChangedTrapThis trap is sent to indicate that the executable image for the MPM has been changed. Upon reset of the MPM card, this new bootfile will be used. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3002
luxNdateTimeSetTrapThis trap is sent to indicate that the date and time of the system has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3003
luxNuserAddedTrapThis trap is sent to indicate that a new user has been added to the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3004
luxNuserDeletedTrapThis trap is sent to indicate that a user has been deleted from the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3005
luxNuserPasswordChangeTrapThis trap is sent to indicate that the password of one of the user's has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3006
luxNuserLevelModifiedTrapThis trap is sent to indicate that the privilege level of one of the user's has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3007
luxNsystemNameChangeTrapThis trap is sent to indicate that the name of the system has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3008
luxNcardAddedTrapThis trap is sent to indicate that a new card has been added to the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3009
luxNcardDeletedTrapThis trap is sent to indicate that a card has been deleted from the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3010
luxNmpmRedundancySwitchOverTrapThis trap is sent to indicate that a mpm switchover has occurred. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3011
luxNconnectionAddedTrapThis trap is sent to indicate that a connectino has been added to an ofcm/ofcd card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3012
luxNconnectionDeletedTrapThis trap is sent to indicate that a connection has been deleted from an ofcm/ofcd card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3013
luxNipAddressChangedTrapThis trap is sent to indicate that the IP address has been changed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3014
luxNipNetmaskChangedTrapThis trap is sent to indicate that the netmask has been changed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3015
luxNdefaultGatewayChangedTrapThis trap is sent to indicate that the default gateway has been changed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3016
luxNGetCommunityChangeTrapThis trap is sent to indicate that the getcommunity has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3017
luxNSetCommunityChangeTrapThis trap is sent to indicate that the setcommunity has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3018
luxNModuleResetTrapThis trap is sent to indicate that a module has been reset. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3019
luxNtopologyRediscoveredTrapThis trap is sent to indicate that the topology database has been rediscovered which is triggered through either CLI or snmp. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3020
luxNcolorsimEnabledTrapThis trap is sent to indicate that the ColorSIM feature has been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3021
luxNcolorsimDisabledTrapThis trap is sent to indicate that the ColorSIM feature has been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3022
luxNautoCutoffEnabledTrapThis trap is sent to indicate that the auto cutoff feature has been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3023
luxNautoCutoffDisabledTrapThis trap is sent to indicate that the auto cutoff feature has been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3024
luxNextAlarmsEnabledTrapThis trap is sent to indicate that the external alarm closures have been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3025
luxNextAlarmsDisabledTrapThis trap is sent to indicate that the external alarm closures have been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3026
luxNdlModuleActivatedTrapThis trap is sent to indicate that a module activation, switching to another module image version, has occurred. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3027
luxNhttpEnabledTrapThis trap is sent to indicate that the http server has been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3032
luxNhttpDisabledTrapThis trap is sent to indicate that the http server has been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3033
luxNstaticRouteAddedTrapThis trap is sent to indicate that a new route has been added to the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. The eveDescr field consists of trap description and the route information - local CC shelf, slot and destination IP address
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3034
luxNstaticRouteDeletedTrapThis trap is sent to indicate that a route has been deleted from the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. The eveDescr field consists of trap description and the route information - local CC shelf, slot and destination IP address
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3035
luxNupsrProtectionSwitchOverSrcThis trap is sent to indicate that UPSR protection switch over occurred on the source either through SNMP or CLI. If the module type is OCM for this trap, then after issuing this trap it goes into standby mode. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3036
luxNupsrProtectionSwitchOverDestThis trap is sent to indicate that UPSR protection switch over occurred on the destination either through SNMP or CLI. If the module type is OCM for this trap, then after issuing this trap it goes into active mode The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3037
luxNimnIpAddressChangedThis trap is sent to indicate that a IMN Ip address is successfully changed either through SNMP or CLI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3038
luxNupsrNormalThis trap is sent to indicate that UPSR is successfully enabled either through SNMP or CLI on the system. This is done once UPSR functionality is normal on the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3039
luxNupsrDegradedThis trap is sent to indicate that UPSR is successfully disabled either through SNMP, CLI or SPI driver on the system. This is done after the UPSR functionality on the system is degraded The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3040
luxNusrOneAlarmActionThis trap is sent to indicate that user has performed acknowledgment/ unacknowledgment/Clearing of a single alarm in the alarm log either through SNMP or CLI . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3041
luxNusrAllAlarmActionThis trap is sent to indicate that user has performed acknowledgment/ unacknowledgment/Clearing of all alarms in the alarm log either through SNMP or CLI . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3042
luxNringConfigurationChangedThis trap is sent to indicate that the user has changed the ring configuration either through deletion or addition of ringId or pathId. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. The eveDescr field consists of trap description and the cross connect information
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3047
luxNeventLogClearedThis trap is sent to indicate that the user has cleared the event log either through CLI or SNMP. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3048
luxNextAlarmInpTrapThis trap is sent when an user sets up alarm severity (crit/maj/minor/disable) on external alarm input. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3049
luxNextAudioAlarmTrapThis trap is sent when an user enables or disables audio alarm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3050
luxNTrapHostConfigChangeTrapThis trap is sent when a trap host is added, deleted, or modified (port configuration). The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3051
luxNTrapHostImnRouteEnabled
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3052
luxNTrapHostImnRouteDisabled
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3053
luxNTrapHostAutoUpdateEnabled
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3054
luxNTrapHostAutoUpdateDisabled
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3055
luxNTrapPathAddedThis trap is sent when a path is configured. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3056
luxNTrapPathDeletedThis trap is sent when a path is deleted. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3057
luxNdlModuleActivateFailedTrapThis trap is sent when a module activation, switching to another module image version, has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3058
luxNLogServerAddedTrapThis trap is sent when a syslog server has been added. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3059
luxNLogServerDeletedTrapThis trap is sent when a syslog server has been deleted. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3060
luxNLogMaskChangedTrapThis trap is sent when the syslog mask has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3061
luxNRadiusAuthChangedTrapThis trap is sent when the radius authentication order has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3062
luxNRadiusDefaultRealmChangedTrapThis trap is sent when the radius default realm has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3063
luxNRadiusNasIdChangedTrapThis trap is sent when the radius NAS Identifier has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3064
luxNRadiusRetriesChangedTrapThis trap is sent when the radius retries has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3065
luxNRadiusServerAddedTrapThis trap is sent when a radius server has been added. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3066
luxNRadiusServerDeletedTrapThis trap is sent when radius server has been deleted. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3067
luxNRadiusServerModifiedTrapThis trap is sent when radius server port or secret has been modified. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3068
luxNRadiusTimeoutChangedTrapThis trap is sent when the radius timeout has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3069
luxNSshEnabledTrapThis trap is sent when the SSHD has been enabled. The source is a 4 or 5 tuple specifying the type location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3070
luxNSshDisabledTrapThis trap is sent when the SSHD has been disabled. The source is a 4 or 5 tuple specifying the type location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3071
luxNSshKeySizeSetTrapThis trap is sent when the SSHD key size has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3072
luxNSshMaxSessionsSetTrapThis trap is sent when the telnet/SSHD max sessions has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3073
luxNSshKeyGeneratedTrapThis trap is sent when the SSH DSS key has finished being generated. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.3074
luxNlogonIntruderTrapThis trap is sent to indicate that someone is repeatly trying to logon using an invalid password. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.4000
luxNlogonSessionStartedThis trap is sent to indicate that a user has logged into the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.4001
luxNlogonSessionClosedThis trap is sent to indicate that a user has logged out of the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.4002
luxNcpAuthenticationErrorTrapThis trap is sent to indicate that an invalid login attempt has been detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
TRAP-TYPE
.1.3.6.1.4.1.4253.0.4003
configuration
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1
manufacturing
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.1
mfgNameManufacturing name of the device. Up to 30 charactersro
DisplayString
.1.3.6.1.4.1.4253.1.1.1
mfgDateDate and Time of manufacturing of the chassisro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.1.2
mfgSerialNumSerial # of the Chassis.ro
SerialString
.1.3.6.1.4.1.4253.1.1.3
mfgModelTypeModel type of the chassis. Up to 10 characters
ModelString
.1.3.6.1.4.1.4253.1.1.4
mfgDefaultIDDefault one-time user ID. This ID should be used for the first time access to the system. This ID will not be accepted once a real user ID is added.ro
LogonID
.1.3.6.1.4.1.4253.1.1.5
mfgDfltPasswdDefault one-time password to go with the default user ID. The password may contain non-printable characters up to 10 ASCII characters. Passwords are hashed and are for comparison onlyro
HashedPasswd
.1.3.6.1.4.1.4253.1.1.6
mfgNumShelvesNumber of shelves in the chassis. This number reflects the number of rows of the table below. This number is automatically adjusted everytime a row is added to the table below.ro
CardShelf
.1.3.6.1.4.1.4253.1.1.9
mfgShelfTableThis table represents the number of shelves and the number of slots per shelf in the chassis.
SEQUENCE OF MfgShelfEntry
.1.3.6.1.4.1.4253.1.1.10
mfgShelfEntrySpecifies the index for each row in the table below
MfgShelfEntry
.1.3.6.1.4.1.4253.1.1.10.1
mfgShelfIDInteger ID of each shelf in the chassis. The shelf number is always one for both GM1608 and GM3217. In the case of of GM3234, the bottom shelf is 1 while the top shelf is 2. As for GMX128, the order of numbering is from the top shelf to the bottom shelf. In other words, the top shelf is assigned 1.ro
CardShelf
.1.3.6.1.4.1.4253.1.1.10.1.1
mfgNumSlotstotal number of slots in a given shelf.ro
CardSlot
.1.3.6.1.4.1.4253.1.1.10.1.2
mfgCRCChecksum32 bit CRC of the manufacturing section. This CRC is automatically calculated everytime information is updated from the manufacturing section. The manufacturing section is static once the chassis leaves the LuxN manufacturing premise.ro
DisplayString
.1.3.6.1.4.1.4253.1.1.11
mfgChassisTypeType of chassis.ro
ChassisType
.1.3.6.1.4.1.4253.1.1.12
mfgPsTypeType of power supplies.ro
Enumeration
.1.3.6.1.4.1.4253.1.1.13
mfgCleiNumCLEI number for the chassis.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.1.14
cp
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.2
cpIpAddressIP Address of the Active Communication Processorrw
IpAddress
.1.3.6.1.4.1.4253.1.2.1
cpNetMaskNet mask for the Active Communication Processorrw
IpAddress
.1.3.6.1.4.1.4253.1.2.2
cpMIBVersionVersion of the LuxN MIB implemented by this device. This value may be reset everytime a new CP code is downloaded.ro
VersionString
.1.3.6.1.4.1.4253.1.2.3
cpBootPromVerThe current version string of the Boot PROM codero
VersionString
.1.3.6.1.4.1.4253.1.2.4
cpROMSizeTotal Size of the ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.2.5
cpNumSubDivNumber of the subdivisions of the ROM.ro
INTEGER
.1.3.6.1.4.1.4253.1.2.6
cpSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF CpSubDivEntry
.1.3.6.1.4.1.4253.1.2.7
cpSubDivEntrySpecifies the index for each row in the table below
CpSubDivEntry
.1.3.6.1.4.1.4253.1.2.7.1
cpSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.ro
INTEGER
.1.3.6.1.4.1.4253.1.2.7.1.1
cpSubDivDescrDisplay Name of each Sub Division in ROMro
DisplayString
.1.3.6.1.4.1.4253.1.2.7.1.2
cpSubDivSizeSize of each sub division in ROM in bytesro
INTEGER
.1.3.6.1.4.1.4253.1.2.7.1.3
cpSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.2.7.1.4
cpSubDivImgVersionDisplay Version of each Images in ROM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.2.7.1.5
cpSubDivImgDBVersionDisplay Database Version of each Images in ROM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.2.7.1.6
cpTableThis table represents the information for each active or standby communication processor
SEQUENCE OF CpEntry
.1.3.6.1.4.1.4253.1.2.8
cpEntrySpecifies the index for each row in the table below
CpEntry
.1.3.6.1.4.1.4253.1.2.8.1
cpCardShelfThe shelf the card is in.ro
CardShelf
.1.3.6.1.4.1.4253.1.2.8.1.1
cpCardSlotThe slot within the shelf the card is in.ro
CardSlot
.1.3.6.1.4.1.4253.1.2.8.1.2
cpModeType of the communication processor. The valid types are Active or Standby.ro
RedundancyMode
.1.3.6.1.4.1.4253.1.2.8.1.3
cpDsgntdModeDesignation Type of the communication processor. The valid types are Active or Standby.ro
RedundancyMode
.1.3.6.1.4.1.4253.1.2.8.1.4
cpStateThe state of the CP card.ro
CardState
.1.3.6.1.4.1.4253.1.2.8.1.5
cpMacAddrMAC address of the Communication processor in HEXro
OCTET STRING
.1.3.6.1.4.1.4253.1.2.8.1.6
cpNameDisplay (Network) name of the Communication processorrw
DisplayString
.1.3.6.1.4.1.4253.1.2.8.1.7
cpMfgDateDate and Time of manufacturing of the CP card
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.2.8.1.8
cpSerialNumSerial # of the CP card.ro
SerialString
.1.3.6.1.4.1.4253.1.2.8.1.9
cpModelTypeModel type of the CP.ro
CardType
.1.3.6.1.4.1.4253.1.2.8.1.10
cpFWVersionIDThe current version string of the CP FW codero
VersionString
.1.3.6.1.4.1.4253.1.2.8.1.11
cpSetStateInstruct the CP to do a warmboot. A get on this will always return an other.rw
RebootType
.1.3.6.1.4.1.4253.1.2.8.1.12
cpHWNameDisplay Hardware name of the CP Card.ro
DisplayString
.1.3.6.1.4.1.4253.1.2.8.1.13
cpCleiNumCLEI number of the mux/dmux Card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.2.8.1.14
cpModelNumModel number of the CP card. Up to 15 charactersro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.2.8.1.15
cpSetModeToggle the Active/Standby mode of the active CP.rw
RedundancyMode
.1.3.6.1.4.1.4253.1.2.9
cpSNMPTrapHost1IP Address of the first SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.10
cpSNMPTrapHost2IP Address of the second SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.11
cpSNMPTrapHost3IP Address of the third SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.12
cpSNMPSendTrapIf set to true, traps will be sent out. If set to false, traps will not be sent out. This variable is reset to true (enable) on each boot cycle.rw
Boolean
.1.3.6.1.4.1.4253.1.2.13
cpGatewayGateway IP Address of the Active Communication Processor. A NULL IP address means Gateway hasn't been configured.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.14
cpMaxSessionsMaximum allowed Telnet Sessions on the Active Communication Processor. Valid values are 1 to 6.rw
INTEGER
.1.3.6.1.4.1.4253.1.2.15
cpSessionTimeoutMaximum timeout (in seconds) that can be set for a Telnet session on the Active Communication Processor. Valid values are greater than 30 secs.rw
INTEGER
.1.3.6.1.4.1.4253.1.2.16
cpDateCurrent Date on the Active Communication Processor. The format is in the form of mm-dd-yy in which mm is the two digit month, dd is the two digit day of the month, and yy is the two digit year.rw
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.2.17
cpTimeCurrent Time on the Active Communication Processor. The format is in the form of hh:mm:ss in which hh is the hour, mm is the minute and ss is the second. The valid values for hour goes from 0 to 23. In order to work with LuxN NMS, it needs to be set to GMT timerw
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.2.18
cpGetCommunityUser configurable SNMP Get Community String.rw
EncryptedCommunity
.1.3.6.1.4.1.4253.1.2.19
cpSetCommunityUser Configurable SNMP Set Community String.rw
EncryptedCommunity
.1.3.6.1.4.1.4253.1.2.20
cpSystemNameUser Configurable System Name.rw
DisplayString
.1.3.6.1.4.1.4253.1.2.21
cpSNMPTrapCommunity1User configurable trap community string for first trap host. Will return an error if the corresponding trap host is invalid or not set.rw
EncryptedCommunity
.1.3.6.1.4.1.4253.1.2.22
cpSNMPTrapCommunity2User configurable trap community string for second trap host. Will return an error if the corresponding trap host is invalid or not set.rw
EncryptedCommunity
.1.3.6.1.4.1.4253.1.2.23
cpSNMPTrapCommunity3User configurable trap community string for third trap host. Will return an error if the corresponding trap host is invalid or not set.rw
EncryptedCommunity
.1.3.6.1.4.1.4253.1.2.24
cpHttpHTTP server enabled or not.
Enumeration
.1.3.6.1.4.1.4253.1.2.25
cpIMNIpAddressIMN Ip address. Use for IP/IWMrw
IpAddress
.1.3.6.1.4.1.4253.1.2.26
cpUpsrModeUPSR mode: enable and disable.rw
Enumeration
.1.3.6.1.4.1.4253.1.2.27
cpAutoModuleUpdateFlag to automatically enable/disable module update.rw
Enumeration
.1.3.6.1.4.1.4253.1.2.28
cpSNMPTrapHost4IP Address of the fourth SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.29
cpSNMPTrapHost5IP Address of the fifth SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.30
cpSNMPTrapCommunity4User configurable trap community string for fourth trap host. Will return an error if the corresponding trap host is invalid or not set.rw
EncryptedCommunity
.1.3.6.1.4.1.4253.1.2.31
cpSNMPTrapCommunity5User configurable trap community string for fifth trap host. Will return an error if the corresponding trap host is invalid or not set.rw
EncryptedCommunity
.1.3.6.1.4.1.4253.1.2.32
cpSNMPTrapHostPort1User configurable trap port for the first trap host. Default value is 162rw
INTEGER
.1.3.6.1.4.1.4253.1.2.33
cpSNMPTrapHostPort2User configurable trap port for the second trap host. Default value is 162rw
INTEGER
.1.3.6.1.4.1.4253.1.2.34
cpSNMPTrapHostPort3User configurable trap port for the third trap host. Default value is 162rw
INTEGER
.1.3.6.1.4.1.4253.1.2.35
cpSNMPTrapHostPort4User configurable trap port for the fourth trap host. Default value is 162rw
INTEGER
.1.3.6.1.4.1.4253.1.2.36
cpSNMPTrapHostPort5User configurable trap port for the fifth trap host. Default value is 162rw
INTEGER
.1.3.6.1.4.1.4253.1.2.37
cpRedunSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory of redundant (standby) MPM
SEQUENCE OF CpRedunSubDivEntry
.1.3.6.1.4.1.4253.1.2.38
cpRedunSubDivEntrySpecifies the index for each row in the table below
CpRedunSubDivEntry
.1.3.6.1.4.1.4253.1.2.38.1
cpRedunSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.ro
INTEGER
.1.3.6.1.4.1.4253.1.2.38.1.1
cpRedunSubDivDescrDisplay Name of each Sub Division in ROMro
DisplayString
.1.3.6.1.4.1.4253.1.2.38.1.2
cpRedunSubDivImgVersionDisplay Version of each Images in ROM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.2.38.1.3
cpRedunSubDivImgDBVersionDisplay Database Version of each Images in ROM.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.2.38.1.4
cpTimezoneSpecifies the internation time zone used by the MPM to determine system time. The time zone is only used to system time calculations when NTP is enabledrw
Timezone
.1.3.6.1.4.1.4253.1.2.39
cpNtpStateSpecifies whether NTP support is enabled or disabled.rw
Enumeration
.1.3.6.1.4.1.4253.1.2.40
cpNtpTimeserverSpecifies the NTP time server queries for updates.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.41
cpNtpUpdateIntervalSpecifies the NTP time update interval in minutes.rw
INTEGER
.1.3.6.1.4.1.4253.1.2.42
cpTelnetClientEnable/disable telnet client for active telnet sessions.rw
Enumeration
.1.3.6.1.4.1.4253.1.2.43
cpLogMaskSet the log mask. The masks are equivalent to syslog priorities.rw
Enumeration
.1.3.6.1.4.1.4253.1.2.44
cpLogServer1IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.45
cpLogServer2IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.46
cpLogServer3IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.47
cpLogServer4IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.48
cpLogServer5IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected.rw
IpAddress
.1.3.6.1.4.1.4253.1.2.49
cc
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.3
ccBootPromVerThe current version string of the CC Boot PROM code
VersionString
.1.3.6.1.4.1.4253.1.3.1
ccROMSizeTotal Size of the CC ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.3.2
ccNumSubDivNumber of the subdivisions of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.3.3
ccSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF CcSubDivEntry
.1.3.6.1.4.1.4253.1.3.4
ccSubDivEntrySpecifies the index for each row in the table below
CcSubDivEntry
.1.3.6.1.4.1.4253.1.3.4.1
ccSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.3.4.1.1
ccSubDivDescrDisplay Name of each Sub Division in ROM
DisplayString
.1.3.6.1.4.1.4253.1.3.4.1.2
ccSubDivSizeSize of each sub division in ROM in kilobytes
INTEGER
.1.3.6.1.4.1.4253.1.3.4.1.3
ccSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.3.4.1.4
ccNumberNumber of CC rows in the following table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.3.5
ccTableThis table represents the information for each channel card
SEQUENCE OF CcEntry
.1.3.6.1.4.1.4253.1.3.6
ccEntrySpecifies the index for each row in the table below
CcEntry
.1.3.6.1.4.1.4253.1.3.6.1
ccCardLocationLocation of the card. Valid values are: Local in the same chassis, or remote to this chassisro
CardLocation
.1.3.6.1.4.1.4253.1.3.6.1.1
ccCardShelfThe shelf the card is in. Valid values are: 1 to 2ro
CardShelf
.1.3.6.1.4.1.4253.1.3.6.1.2
ccCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.3.6.1.3
ccMfgDateDate and Time of calibration of the CC cardro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.3.6.1.4
ccSerialNumSerial # of the CC card.ro
SerialString
.1.3.6.1.4.1.4253.1.3.6.1.5
ccModelTypeModel type of the channel card.ro
CardType
.1.3.6.1.4.1.4253.1.3.6.1.6
ccNameUser configurable name of the channel cardrw
CardName
.1.3.6.1.4.1.4253.1.3.6.1.7
ccFWVersionIDThe current version string of the CC FW codero
VersionString
.1.3.6.1.4.1.4253.1.3.6.1.8
ccMfgBiasCurrentBias current for the optical laser. This is the preset manufacturing valuero
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.9
ccMfgModulationThe frequency modulation for the optical laser. This value is the preset manufacturing value.ro
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.10
ccMfgApcThe APC value. This value is the preset manufacturing valuero
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.11
ccMfgIwmModulationThe frequency modulation for the IWM channel. This value is the preset manufacturing valuero
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.12
ccMfgRefClockThe value of the reference clock in decimal notation. For a given value, like 1660-EN, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor. This value is the preset manufacturing value.
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.13
ccMfgClockDivThe clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale.
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.14
ccBandwidthThe bandwidth of the channel card.rw
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.15
ccSetStateInstruct the CC to do a warmboot or loopback. A get on this will always return an other.rw
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.16
connMuxChassisThe connected mux chassis.
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.17
connMuxShelfThe connected mux shelf.ro
ShelfInput
.1.3.6.1.4.1.4253.1.3.6.1.18
connMuxSlotThe connected mux slot.ro
SlotInput
.1.3.6.1.4.1.4253.1.3.6.1.19
connMuxPortThe connected mux port.ro
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.20
connDemuxChassisThe connected demux chassis.
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.21
connDemuxShelfThe connected demux shelf.ro
ShelfInput
.1.3.6.1.4.1.4253.1.3.6.1.22
connDemuxSlotThe connected demux slot.ro
SlotInput
.1.3.6.1.4.1.4253.1.3.6.1.23
connDemuxPortThe connected demux port.ro
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.24
ccModelNumModel number of the CC card. Up to 15 charactersro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.3.6.1.25
ccLinkITUNumLink ITU number of the CC card. Up to 15 charactersro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.3.6.1.26
ccLinkWavelengthLink Wavelength of the CC cardro
DisplayString
.1.3.6.1.4.1.4253.1.3.6.1.27
ccLaserTypeLaser Type of the Channel Card.ro
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.28
ccRecvDiodeReceive Diode of the Channel Card.ro
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.29
ccLinkAutoDisableFlag to enable/disable the CPE link when the threshold value crosses the lower hysteresis limit. The default value is disable. CPE disable with CPE Rx pass through is identical to normal CPE disable with the added feature that the remote CPE Tx will be disabled if a loss of light condition is detected on the local CPE Rx.rw
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.30
ccLinkNameLink name for fiber between the local and the remote cc card.rw
LinkName
.1.3.6.1.4.1.4253.1.3.6.1.31
ccCsimModuleWhether colorSIM module is physically present, not installed or preconfigured.ro
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.32
ccHWNameDisplay Hardware name of the CC Card.ro
CardName
.1.3.6.1.4.1.4253.1.3.6.1.33
ccBackpackModulePresence of Backpack module, installed or not Installed.ro
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.34
ccBackpackRxITUNumberRx ITU number of backpack.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.3.6.1.35
ccBackpackTxITUNumberTx ITU number of backpack.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.3.6.1.36
ccBackpackRxInsertionLossRx Insertion loss of backpack.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.3.6.1.37
ccBackpackTxInsertionLossTx Insertion loss of backpack.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.3.6.1.38
ccBackpackRxExpressLossRx Express loss of backpack.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.3.6.1.39
ccBackpackTxExpressLossTx Express loss of backpack.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.3.6.1.40
ccSwitchByShelfSlotInitiate manual UPSR switching by shelf and slot.rw
DisplayString
.1.3.6.1.4.1.4253.1.3.6.1.41
ccPathIDUpsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.3.6.1.42
ccCpeDisableThresholdCPE Disable Threshold (Link Rx Power) in dBm. The limit is from -32 to -8, but input should be an absolute value if using mib browser. A value of 0 in this field indicates that UPSR is not supported. This value will not take affect until ccLinkAutoDisable has been enabled.rw
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.43
ccCpeReEnableThresholdCPE Re-enable threshold (Link Rx Power) in dBm. The limit is from -31 to -7, but input should be an absolute value if using mib browser. A value of 0 in this field indicates that UPSR is not supported. This value will not take affect until ccLinkAutoDisable has been enabled.rw
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.44
connTxNonMuxDmuxCardTypeType of module connected to Tx port of OCM.ro
CardType
.1.3.6.1.4.1.4253.1.3.6.1.45
connTxNonMuxDmuxPortConn port for CC's Tx port.Possible values based on card types that can connect to OCM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCMU/OCMITU/MCMT1/MCME1/OCM10G/OCM10G: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.ro
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.46
connTxNonMuxDmuxShelfThe shelf the card conn to Tx port of OCM. Valid values are: 1 to 10.ro
ShelfInput
.1.3.6.1.4.1.4253.1.3.6.1.47
connTxNonMuxDmuxSlotThe slot within the shelf the card conn to Tx port of OCM.ro
SlotInput
.1.3.6.1.4.1.4253.1.3.6.1.48
connRxNonMuxDmuxCardTypeType of module connected to Rx port of OCM.ro
CardType
.1.3.6.1.4.1.4253.1.3.6.1.49
connRxNonMuxDmuxPortConn port for CC's Rx port.Possible values based on card types that can connect to OCM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCMU/OCMITU/MCMT1/MCME1/OCM10G/OCM10G: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.ro
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.50
connRxNonMuxDmuxShelfThe shelf the card conn to Rx port of OCM. Valid values are: 1 to 10.ro
ShelfInput
.1.3.6.1.4.1.4253.1.3.6.1.51
connRxNonMuxDmuxSlotThe slot within the shelf the card conn to Rx port of OCM.ro
SlotInput
.1.3.6.1.4.1.4253.1.3.6.1.52
ccUpsrModeUPSR mode for CC card: primary or backup. If not in upsr configuration, value is na. This value will not take affect until ccLinkAutoDisable has been enabled.rw
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.53
ccPairShelfThe shelf of other CC card in pair.rw
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.54
ccPairSlotThe slot of other CC card in pair. Input 0 to unpair OCMs and delete RSM connections if any.rw
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.55
ccAdminStateAdministrative control over that cc card. Default value is enable. When disabled, no alarms/events gets generated. For remote CC, the default value is disabledrw
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.56
ccRegenPairShelfThe shelf of other CC card in OCM regeneration pair. This value will not take affect until ccLinkAutoDisable has been enabled.rw
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.57
ccRegenPairSlotThe slot of other CC card in OCM regeneration pair. Input 0 to unpair OCMs involved. This value will not take affect until ccLinkAutoDisable has been enabled.rw
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.58
ccCleiNumCLEI number of the CC Card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.3.6.1.59
connCpeTxMcmescShelfThe connected MCMESC shelf.ro
ShelfInput
.1.3.6.1.4.1.4253.1.3.6.1.60
connCpeTxMcmescSlotThe connected MCMESC slot.ro
SlotInput
.1.3.6.1.4.1.4253.1.3.6.1.61
connCpeTxMcmescPortThe connected MCMESC port. 1=Link Tx, 2=Link Rx.ro
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.62
connCpeRxMcmescShelfThe connected MCMESC shelf.ro
ShelfInput
.1.3.6.1.4.1.4253.1.3.6.1.63
connCpeRxMcmescSlotThe connected MCMESC slot.ro
SlotInput
.1.3.6.1.4.1.4253.1.3.6.1.64
connCpeRxMcmescPortThe connected MCMESC port. 1=Link Tx, 2=Link Rx.ro
Enumeration
.1.3.6.1.4.1.4253.1.3.6.1.65
ccNumPortsTotal port numbers on each CC card.ro
INTEGER
.1.3.6.1.4.1.4253.1.3.6.1.66
mux
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.4
muxBootPromVerThe current version string of the Mux Boot PROM code
VersionString
.1.3.6.1.4.1.4253.1.4.1
muxROMSizeTotal Size of the ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.4.2
muxNumSubDivNumber of the subdivisions of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.4.3
muxSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF MuxSubDivEntry
.1.3.6.1.4.1.4253.1.4.4
muxSubDivEntrySpecifies the index for each row in the table below
MuxSubDivEntry
.1.3.6.1.4.1.4253.1.4.4.1
muxSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.4.4.1.1
muxSubDivDescrDisplay Name of each Sub Division in ROM
DisplayString
.1.3.6.1.4.1.4253.1.4.4.1.2
muxSubDivSizeSize of each sub division in ROM in kilobytes
INTEGER
.1.3.6.1.4.1.4253.1.4.4.1.3
muxSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.4.4.1.4
muxNumberNumber of MUX rows in the following table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.4.5
muxTableThis table represents the information for each MUX card
SEQUENCE OF MuxEntry
.1.3.6.1.4.1.4253.1.4.6
muxEntrySpecifies the index for each row in the table below
MuxEntry
.1.3.6.1.4.1.4253.1.4.6.1
muxCardLocationLocation of the module. Valid values are: Local in the same chassis, or remote to this chassisro
CardLocation
.1.3.6.1.4.1.4253.1.4.6.1.1
muxCardShelfThe shelf the card is in.ro
CardShelf
.1.3.6.1.4.1.4253.1.4.6.1.2
muxCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.4.6.1.3
muxModelNumModel number for module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.4.6.1.4
muxMfgDateDate and Time of manufacturing of the module
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.4.6.1.5
muxSerialNumSerial # of the module.ro
SerialString
.1.3.6.1.4.1.4253.1.4.6.1.6
muxModelTypeModel type of the modulero
CardType
.1.3.6.1.4.1.4253.1.4.6.1.7
muxNameUser configurable name of the modulerw
CardName
.1.3.6.1.4.1.4253.1.4.6.1.8
muxFWVersionIDThe current version string of the FW codero
VersionString
.1.3.6.1.4.1.4253.1.4.6.1.9
muxSetStateInstruct the mux to do a warmboot. A get on this will always return an other.rw
RebootType
.1.3.6.1.4.1.4253.1.4.6.1.10
muxNumPortsTotal port numbers on each MUX card. Should be sixro
INTEGER
.1.3.6.1.4.1.4253.1.4.6.1.11
muxUpgradeFlagThe MUX card's status is upgradable or not.ro
Enumeration
.1.3.6.1.4.1.4253.1.4.6.1.12
muxHWNameDisplay Hardware name of the mux/dmux Card.ro
CardName
.1.3.6.1.4.1.4253.1.4.6.1.13
muxPathIDUpsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.4.6.1.14
muxAdminStateAdministrative control over that mux card. Default value is enable. When disabled, no alarms/events gets generated.rw
Enumeration
.1.3.6.1.4.1.4253.1.4.6.1.15
muxCleiNumCLEI number of the mux/dmux Card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.4.6.1.16
muxChannelSpacingITU channel spacing for the mux/demux card. Only valid for MD100-40 and BD4 Modules.ro
INTEGER
.1.3.6.1.4.1.4253.1.4.6.1.17
muxStartItuFirst ITU channel supported by the module. Only valid for MD100-40 and BD4 Modules.ro
INTEGER
.1.3.6.1.4.1.4253.1.4.6.1.18
muxEndItuLast ITU channel supported by the module. Only valid for MD100-40 and BD4 Modules.ro
INTEGER
.1.3.6.1.4.1.4253.1.4.6.1.19
muxChannelsPerBandNumber of channels per optical band supported by the module. Only valid for BD-4 and MD100-40 module.ro
INTEGER
.1.3.6.1.4.1.4253.1.4.6.1.20
muxBandsNumber of bands supported by the module. Only valid for BD-4 and MD100-40 module.ro
INTEGER
.1.3.6.1.4.1.4253.1.4.6.1.21
muxPortNumberNumber of MUX's port rows in the following table. This number is automatically updated whenever a new row is added to the table below.Basically a product of # of mux cards and # of ports on each card. Hence it would have a value of 6, 12, 18 etc..ro
INTEGER
.1.3.6.1.4.1.4253.1.4.7
muxPortTableThis table represents the information for each MUX card's port.
SEQUENCE OF MuxPortEntry
.1.3.6.1.4.1.4253.1.4.8
muxPortEntrySpecifies the index for each row in the table below
MuxPortEntry
.1.3.6.1.4.1.4253.1.4.8.1
muxPortCardLocationLocation of the MUX's port. Valid values are: Local in the same chassis, or remote to this chassisro
CardLocation
.1.3.6.1.4.1.4253.1.4.8.1.1
muxPortCardShelfThe shelf the card is in. Valid values are: 1 to 2.ro
CardShelf
.1.3.6.1.4.1.4253.1.4.8.1.2
muxPortCardSlotThe slot within the shelf the card is in.ro
SlotInput
.1.3.6.1.4.1.4253.1.4.8.1.3
muxPortIndexPort's index. Ports 1 through 4 can be use for connection with OCM family or MCMT1/MCME1 only.ro
INTEGER
.1.3.6.1.4.1.4253.1.4.8.1.4
muxWavelengthPort's wavelength: either ITU number or actual wavelength in nm. Supported by all Mux modules except MD100-40 & BD4.ro
INTEGER
.1.3.6.1.4.1.4253.1.4.8.1.5
muxInsertLossMux Port insertion Loss range. Supported by all Mux modules except MD100-40 & BD4.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.4.8.1.6
muxConnCardTypeModule type connected to mux port. Supported by all Mux modules except MD100-40 & BD4.rw
CardType
.1.3.6.1.4.1.4253.1.4.8.1.7
muxConnLocationThe chassis's location of the card conn to. Supported by all Mux modules except MD100-40 & BD4.rw
CardLocation
.1.3.6.1.4.1.4253.1.4.8.1.8
muxConnShelfThe shelf the card conn to. Valid values are: 1 to 2. Supported by all Mux modules except MD100-40 & BD4.rw
ShelfInput
.1.3.6.1.4.1.4253.1.4.8.1.9
muxConnSlotThe slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0. Supported by all Mux modules except MD100-40 & BD4.rw
SlotInput
.1.3.6.1.4.1.4253.1.4.8.1.10
muxConnPortConn port for MUX/DMUX's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4.rw
INTEGER
.1.3.6.1.4.1.4253.1.4.8.1.11
muxPortTypeType of the MUX's port. Supported by all Mux modules except MD100-40 & BD4.ro
Enumeration
.1.3.6.1.4.1.4253.1.4.8.1.12
muxConnChassisIDChassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node. Supported by all Mux modules except MD100-40 & BD4.rw
DisplayString
.1.3.6.1.4.1.4253.1.4.8.1.13
muxConnSystemNameSystem Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node. Supported by all Mux modules except MD100-40 & BD4.rw
DisplayString
.1.3.6.1.4.1.4253.1.4.8.1.14
muxConnIpAddressIpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node. Supported by all Mux modules except MD100-40 & BD4.rw
IpAddress
.1.3.6.1.4.1.4253.1.4.8.1.15
muxPortAvgInsertionLossAverage port insertion loss for the port category. Valid only for MD100-40 & BD4 modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.4.8.1.16
muxPortMaxInsertionLossMaximum port insertion loss for the port category. Valid only for MD100-40 & BD4 modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.4.8.1.17
muxPortTapRatioTap ratio for the port category. Valid only for MD100-40 & BD4 modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.4.8.1.18
ps
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.5
psNumberNumber of PS (power supply) rows in the following table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.5.1
psTableThis table represents the information for each PS module.
SEQUENCE OF PsEntry
.1.3.6.1.4.1.4253.1.5.2
psEntrySpecifies the index for each row in the table below
PsEntry
.1.3.6.1.4.1.4253.1.5.2.1
psIDThe module ID the ps module is in. Valid values are: 1 to 4
INTEGER
.1.3.6.1.4.1.4253.1.5.2.1.1
psModeMode of the PS module. Valid values are: active or standby
RedundancyMode
.1.3.6.1.4.1.4253.1.5.2.1.2
psMfgDateDate and Time of manufacturing of the PS module.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.5.2.1.3
psSerialNumSerial # of the PS module. Not Supported Yet.
SerialString
.1.3.6.1.4.1.4253.1.5.2.1.4
psModelTypeModel type of the PS module. Up to 10 characters. Not Supported Yet.
ModelString
.1.3.6.1.4.1.4253.1.5.2.1.5
download
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.6
dlFtpTableThis table represents the information for each FTP server
SEQUENCE OF DlFtpEntry
.1.3.6.1.4.1.4253.1.6.1
dlFtpEntrySpecifies the index for each row in the table below
DlFtpEntry
.1.3.6.1.4.1.4253.1.6.1.1
dlFtpIpThe IP address of the FTP server.rw
IpAddress
.1.3.6.1.4.1.4253.1.6.1.1.1
dlFtpLogonIDThe FTP user ID for this FTP server. Up to 15 chars.rw
LogonID
.1.3.6.1.4.1.4253.1.6.1.1.2
dlFtpPasswdPassword for the above FTP Logon ID. This password is NOT hashed. Proper security access is required to set and view this element. Most FTP connections, however, are using anonymous logon ID with no special password requirements.rw
DisplayString
.1.3.6.1.4.1.4253.1.6.1.1.3
dlFtpModeFTP server modes. The choices are: active or passive, active may be necessary for users behind a firewall.rw
FtpMode
.1.3.6.1.4.1.4253.1.6.1.1.4
dlFtpPortFTP port. This port is used in conjunction with the FTP IP address for establishing a connection to the FTP server. Any valid IP port may be entered. Setting this element to zero (0) will cause the standard FTP port (21) to be used.rw
INTEGER
.1.3.6.1.4.1.4253.1.6.1.1.5
dlPreQualTableThis table represents the information for each PreQual table.
SEQUENCE OF DlPreQualEntry
.1.3.6.1.4.1.4253.1.6.2
dlPreQualEntrySpecifies the index for each row in the table below
DlPreQualEntry
.1.3.6.1.4.1.4253.1.6.2.1
dlPreQualTypeVersionThe Image type and version to be prequalified before downloading. The string format is : type,version. The prequal action will be taken after setting version.rw
DisplayString
.1.3.6.1.4.1.4253.1.6.2.1.1
dlPreQualResultThe result after comparing type and version of the selected download image with the compatibility matrix. The result is either compatible, incompatible or unknown version. (Not available at this time). The default is compatible.ro
Enumeration
.1.3.6.1.4.1.4253.1.6.2.1.2
dlDownloadTableThis table represents the information for download and activation.
SEQUENCE OF DlDownloadEntry
.1.3.6.1.4.1.4253.1.6.3
dlDownloadEntrySpecifies the index for each row in the table below
DlDownloadEntry
.1.3.6.1.4.1.4253.1.6.3.1
dlTypeThe Image type to be downloaded or to be activated. The valid values are: all, mpms, boot, macf, mcme1, mcmesc-code, mcmt1, mpm, ocm, ocm10g, oet, osam, osam-hp/lp, rsm, upsm, uob. When choosing all, all non-mpm images are downloaded, the dlLocation should be set to local, dlShelf and dlSlot should be set to 0, dlFilename should be set to the path under which all the non-mpm images are put. When choosing mpms, mpm's two associated images, boot and mpm run code image, are downloaded, the dlLocation should be set to local, dlShelf and dlSlot should be set to active mpm's shelf and slot, dlFilename should be set to the path under which the two images are put. To MCME1/MCMT1 modules, mcm-fpag image will automatically be downloaded when mcme1 or mcmt1 is selected.rw
DownloadType
.1.3.6.1.4.1.4253.1.6.3.1.1
dlLocationThe location to be downloaded or to be activated. The choices are: local, remote or both. (Only local and remote are supported at this time, LuxnOS has only local choice and is not supported yet. When dlType is set to all, only local is supported.rw
DownloadLocation
.1.3.6.1.4.1.4253.1.6.3.1.2
dlShelfThe destination shelf. When dlType is set to all, dlShelf should be set to 0.rw
DownloadShelf
.1.3.6.1.4.1.4253.1.6.3.1.3
dlSlotThe slot within the selected shelf. When dlType is set to all, dlSlot should be set to 0.rw
DownloadSlot
.1.3.6.1.4.1.4253.1.6.3.1.4
dlFilenameThe filename and path of the file to be downloaded -up to 255 characters. When dlType is set to all, the dlFilename field should be set to the path of the directory where the non-mpm images are stored. When dlType is set to mpms, the dlFilename field should be set to the path of the directory where the boot and mpm images are stored. The download action (imageupdate) will be taken after setting the dlFilename field.rw
DisplayString
.1.3.6.1.4.1.4253.1.6.3.1.5
dlActivateActivate the backup image at the selected location. To MCMESC, no, activateBackupFirmware, activateBackupFPGA and activateBackupFirmwareAndFPGA are applicable. To MCMT1/MCME1, no and activateBackupFirmwareAndFPGA are applicable. To other modules, no and activateBackupFirmware are applicable. When choosing activateForAllLineCards, the dlShelf and dlSlot sholud be set to 0.rw
Enumeration
.1.3.6.1.4.1.4253.1.6.3.1.6
dlExportTypeThe image indicated by dlType is to be exported to the dlFilename using FTP. Ths element is reset to none(1) after each export.rw
Enumeration
.1.3.6.1.4.1.4253.1.6.3.1.7
dlOSTableThis table represents the information for LuxnOS table.
SEQUENCE OF DlOSEntry
.1.3.6.1.4.1.4253.1.6.4
dlOSEntrySpecifies the index for each row in the table below
DlOSEntry
.1.3.6.1.4.1.4253.1.6.4.1
dlOSIndexThe Integer ID for each LuxnOS.
INTEGER
.1.3.6.1.4.1.4253.1.6.4.1.1
dlOSVersionDisplay the LuxnOS version.
VersionString
.1.3.6.1.4.1.4253.1.6.4.1.2
dlOSStateDisplay the LuxnOS state: operating(1) is the current operating LuxnOS, backup(2)is the backup LuxnOS.
OSState
.1.3.6.1.4.1.4253.1.6.4.1.3
dlOSRelDateDisplay the release date of the LuxnOS.
ReleaseDate
.1.3.6.1.4.1.4253.1.6.4.1.4
dlUpdateOSDisplay and select Update LuxnOS Mode: toggle(1) to toggle between operating and backup LuxnOS, revert(2) to copy LuxnOS from the backup to the operating area. The action will be taken after setting UpdateOS .
UpdateOSMode
.1.3.6.1.4.1.4253.1.6.5
fadm
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.7
fadmBootPromVerThe current version string of the OADM Boot PROM code
VersionString
.1.3.6.1.4.1.4253.1.7.1
fadmROMSizeTotal Size of the ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.7.2
fadmNumSubDivNumber of the subdivisions of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.7.3
fadmSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF FadmSubDivEntry
.1.3.6.1.4.1.4253.1.7.4
fadmSubDivEntrySpecifies the index for each row in the table below
FadmSubDivEntry
.1.3.6.1.4.1.4253.1.7.4.1
fadmSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.7.4.1.1
fadmSubDivDescrDisplay Name of each Sub Division in ROM
DisplayString
.1.3.6.1.4.1.4253.1.7.4.1.2
fadmSubDivSizeSize of each sub division in ROM in kilobytes
INTEGER
.1.3.6.1.4.1.4253.1.7.4.1.3
fadmSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.7.4.1.4
fadmNumberNumber of FADM rows in the following table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.7.5
fadmTableThis table represents the information for each OADM module
SEQUENCE OF FadmEntry
.1.3.6.1.4.1.4253.1.7.6
fadmEntrySpecifies the index for each row in the table below
FadmEntry
.1.3.6.1.4.1.4253.1.7.6.1
fadmCardLocationLocation of the FADM Module.ro
CardLocation
.1.3.6.1.4.1.4253.1.7.6.1.1
fadmCardShelfThe shelf of the Module is in. Valid values are: 1, 2 or 3 depending on the chassis type.ro
CardShelf
.1.3.6.1.4.1.4253.1.7.6.1.2
fadmCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 21 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.7.6.1.3
fadmMfgDateDate and Time of manufacturing of the FADM card
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.7.6.1.4
fadmSerialNumSerial # of the FADM card.ro
SerialString
.1.3.6.1.4.1.4253.1.7.6.1.5
fadmModelTypeModel type of the FADMro
CardType
.1.3.6.1.4.1.4253.1.7.6.1.6
fadmNameDisplay (Network) name of the FADM Cardrw
CardName
.1.3.6.1.4.1.4253.1.7.6.1.7
fadmFWVersionIDThe current version string of the FADM FW codero
VersionString
.1.3.6.1.4.1.4253.1.7.6.1.8
fadmSetStateInstruct the fadm to do a warmboot. A get on this will always return an other.rw
RebootType
.1.3.6.1.4.1.4253.1.7.6.1.9
fadmNumPortsTotal port numbers of FADM module.ro
INTEGER
.1.3.6.1.4.1.4253.1.7.6.1.10
fadmUpgradeFlagThe FADM module's status is upgradeable or not.ro
Enumeration
.1.3.6.1.4.1.4253.1.7.6.1.11
fadmModelNumModel # of the FADM card. Up to 15 charactersro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.7.6.1.12
fadmITUNumber1Port 1's ITU wavelength.ro
INTEGER
.1.3.6.1.4.1.4253.1.7.6.1.13
fadmITUNumber2ro
INTEGER
.1.3.6.1.4.1.4253.1.7.6.1.14
fadmInsertionLoss1Port 1's insertion loss in dB.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.7.6.1.15
fadmInsertionLoss2
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.7.6.1.16
fadmExpressLossInternal express port's insertion loss in dB.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.7.6.1.17
fadmHWNameDisplay Hardware name of the FADM Card.ro
CardName
.1.3.6.1.4.1.4253.1.7.6.1.18
fadmPathIDUpsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.7.6.1.19
fadmAdminStateAdministrative control over that fadm card. Default value is enable. When disabled, no alarms/events gets generated.rw
Enumeration
.1.3.6.1.4.1.4253.1.7.6.1.20
fadmCleiNumCLEI number of the fadm Card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.7.6.1.21
fadmBandOptical band supported by the module. Valid only for BP-5 and BP-10 modules.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.7.6.1.22
fadmChannelsPerBandNumber of channels per optical band supported by the module. Only valid for BP-5 and BP-10module.ro
INTEGER
.1.3.6.1.4.1.4253.1.7.6.1.23
fadmStartItuFirst ITU channel supported by the module. Valid only for BP-5 and BP-10 modules.ro
INTEGER
.1.3.6.1.4.1.4253.1.7.6.1.24
fadmEndItuLast ITU channel supported by the module. Valid only for BP-5 and BP-10 modules.ro
INTEGER
.1.3.6.1.4.1.4253.1.7.6.1.25
fadmPortTableThis table represents the physical connection for each FADM card's port.
SEQUENCE OF FadmPortEntry
.1.3.6.1.4.1.4253.1.7.7
fadmPortEntrySpecifies the index for each row in the table below
FadmPortEntry
.1.3.6.1.4.1.4253.1.7.7.1
fadmPortCardShelfThe shelf the card is in. Valid values are: 1 to 2.ro
CardShelf
.1.3.6.1.4.1.4253.1.7.7.1.1
fadmPortCardSlotThe slot within the shelf the card is in.ro
SlotInput
.1.3.6.1.4.1.4253.1.7.7.1.2
fadmPortTypeType of the FADM port. The order is CLI compatible. For FADM model type, the ports are listed on the left columnro
Enumeration
.1.3.6.1.4.1.4253.1.7.7.1.3
fadmConnLocationThe chassis's location of the card conn to.rw
CardLocation
.1.3.6.1.4.1.4253.1.7.7.1.4
fadmConnIpAddressIpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the noderw
IpAddress
.1.3.6.1.4.1.4253.1.7.7.1.5
fadmConnChassisIDChassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local noderw
DisplayString
.1.3.6.1.4.1.4253.1.7.7.1.6
fadmConnSystemNameSystem Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node.rw
DisplayString
.1.3.6.1.4.1.4253.1.7.7.1.7
fadmConnCardTypeModule type connected to fadm port.rw
CardType
.1.3.6.1.4.1.4253.1.7.7.1.8
fadmConnPortConn port for FADM's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.rw
INTEGER
.1.3.6.1.4.1.4253.1.7.7.1.9
fadmConnShelfThe shelf the card conn to. Valid values are: 1 to 2.rw
ShelfInput
.1.3.6.1.4.1.4253.1.7.7.1.10
fadmConnSlotThe slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.7.7.1.11
oppm
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.8
oppmBootPromVerThe current version string of the oppm Boot PROM code
VersionString
.1.3.6.1.4.1.4253.1.8.1
oppmROMSizeTotal Size of the ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.8.2
oppmNumSubDivNumber of the subdivisions of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.8.3
oppmSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF OppmSubDivEntry
.1.3.6.1.4.1.4253.1.8.4
oppmSubDivEntrySpecifies the index for each row in the table below
OppmSubDivEntry
.1.3.6.1.4.1.4253.1.8.4.1
oppmSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.8.4.1.1
oppmSubDivDescrDisplay Name of each Sub Division in ROM
DisplayString
.1.3.6.1.4.1.4253.1.8.4.1.2
oppmSubDivSizeSize of each sub division in ROM in kilobytes
INTEGER
.1.3.6.1.4.1.4253.1.8.4.1.3
oppmSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.8.4.1.4
oppmNumberNumber of OPPM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
INTEGER
.1.3.6.1.4.1.4253.1.8.5
oppmTableThis table represents the information for each OPPM card
SEQUENCE OF OppmEntry
.1.3.6.1.4.1.4253.1.8.6
oppmEntrySpecifies the index for each row in the table below
OppmEntry
.1.3.6.1.4.1.4253.1.8.6.1
oppmCardLocationLocation of the OPPM card. Valid values are: Local in the same chassis, or remote to this chassis
CardLocation
.1.3.6.1.4.1.4253.1.8.6.1.1
oppmCardShelfThe shelf the card is in. Valid values are: 1 to 2
CardShelf
.1.3.6.1.4.1.4253.1.8.6.1.2
oppmCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
SlotInput
.1.3.6.1.4.1.4253.1.8.6.1.3
oppmModelNumOppm's model number.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.8.6.1.4
oppmMfgDateDate and Time of manufacturing of the OPPM card
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.8.6.1.5
oppmSerialNumSerial # of the OPPM card.
SerialString
.1.3.6.1.4.1.4253.1.8.6.1.6
oppmModelTypeModel type of the OPPM
CardType
.1.3.6.1.4.1.4253.1.8.6.1.7
oppmNameDisplay (Network) name of the OPPM Card
CardName
.1.3.6.1.4.1.4253.1.8.6.1.8
oppmFWVersionIDThe current version string of the OPPM FW code
VersionString
.1.3.6.1.4.1.4253.1.8.6.1.9
oppmSetStateInstruct the oppm to do a warmboot. A get on this will always return an other.
RebootType
.1.3.6.1.4.1.4253.1.8.6.1.10
oppmTxInsertLossTransmit insertion loss.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.8.6.1.12
oppmRxInsertLossReceive insertion loss.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.8.6.1.13
oppmUpgradeFlagThe oppm card's status is upgradable or not.
Enumeration
.1.3.6.1.4.1.4253.1.8.6.1.14
oppmSwitchinstruct the OPPM to take on an action, such as: switch to link A or link B A get would alway return other(1).
Enumeration
.1.3.6.1.4.1.4253.1.8.6.1.15
oppmMarginForSwitchConfigurable switching margin in dB for protection switch to occur.
INTEGER
.1.3.6.1.4.1.4253.1.8.6.1.16
oppmHighAlarmMarginHigh alarm margin for input signal strength displayed in dB unit
INTEGER
.1.3.6.1.4.1.4253.1.8.6.1.17
oppmConfigCommitThis allows the current module configuration, such as oppmMarginForSwitch, to be stored in permanent storage.
Enumeration
.1.3.6.1.4.1.4253.1.8.6.1.18
oppmHWNameDisplay Hardware name of the OPPM Card.
CardName
.1.3.6.1.4.1.4253.1.8.6.1.19
oppmLinkAPathIDOppmm LinkA Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
PathIdName
.1.3.6.1.4.1.4253.1.8.6.1.20
oppmLinkBPathIDOppm LinkB Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
PathIdName
.1.3.6.1.4.1.4253.1.8.6.1.21
oppmAdminStateAdministrative control over that oppm card. Default value is enable. When disabled, no alarms/events gets generated.
Enumeration
.1.3.6.1.4.1.4253.1.8.6.1.22
oppmCleiNumCLEI number of the oppm Card.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.8.6.1.23
oppmSwitchStateThe switching state. Switching state may be either auto or forced. The auto state means automatic switching is enabled. Forced state means swithcing is disabled and has been forced to the current active link.
Enumeration
.1.3.6.1.4.1.4253.1.8.6.1.24
oppmPortTableThis table represents the physical connection for each OPPM card's port.
SEQUENCE OF OppmPortEntry
.1.3.6.1.4.1.4253.1.8.7
oppmPortEntrySpecifies the index for each row in the table below
OppmPortEntry
.1.3.6.1.4.1.4253.1.8.7.1
oppmPortCardShelfThe shelf the card is in. Valid values are: 1 to 2.
CardShelf
.1.3.6.1.4.1.4253.1.8.7.1.1
oppmPortCardSlotThe slot within the shelf the card is in.
SlotInput
.1.3.6.1.4.1.4253.1.8.7.1.2
oppmPortTypeType of the OPPM's port.rw
Enumeration
.1.3.6.1.4.1.4253.1.8.7.1.3
oppmConnLocationThe chassis's location of the card conn to.
CardLocation
.1.3.6.1.4.1.4253.1.8.7.1.4
oppmConnIpAddressIpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node
IpAddress
.1.3.6.1.4.1.4253.1.8.7.1.5
oppmConnChassisIDChassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node
DisplayString
.1.3.6.1.4.1.4253.1.8.7.1.6
oppmConnSystemNameSystem Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node.
DisplayString
.1.3.6.1.4.1.4253.1.8.7.1.7
oppmConnCardTypeModule type connected to oppm port.
CardType
.1.3.6.1.4.1.4253.1.8.7.1.8
oppmConnPortConn port for OPPM's port. Possible values based on card types that can connect to OPPM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.
INTEGER
.1.3.6.1.4.1.4253.1.8.7.1.9
oppmConnShelfThe shelf the card conn to. Valid values are: 1 to 2.
ShelfInput
.1.3.6.1.4.1.4253.1.8.7.1.10
oppmConnSlotThe slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0.
SlotInput
.1.3.6.1.4.1.4253.1.8.7.1.11
mcm
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.9
mcmBootPromVerThe current version string of the mcmt1/mcme1 Boot PROM code
VersionString
.1.3.6.1.4.1.4253.1.9.1
mcmROMSizeTotal Size of the ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.9.2
mcmNumSubDivNumber of the subdivisions of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.9.3
mcmSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF McmSubDivEntry
.1.3.6.1.4.1.4253.1.9.4
mcmSubDivEntrySpecifies the index for each row in the table below
McmSubDivEntry
.1.3.6.1.4.1.4253.1.9.4.1
mcmSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.9.4.1.1
mcmSubDivDescrDisplay Name of each Sub Division in ROM
DisplayString
.1.3.6.1.4.1.4253.1.9.4.1.2
mcmSubDivSizeSize of each sub division in ROM in kilobytes
INTEGER
.1.3.6.1.4.1.4253.1.9.4.1.3
mcmSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.9.4.1.4
mcmNumberNumber of ADM rows in the following table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.9.5
mcmTableThis table represents the information for each mcmt1/mcme1 module
SEQUENCE OF McmEntry
.1.3.6.1.4.1.4253.1.9.6
mcmEntrySpecifies the index for each row in the table below
McmEntry
.1.3.6.1.4.1.4253.1.9.6.1
mcmCardLocationLocation of the mcmt1/mcme1 Module.ro
CardLocation
.1.3.6.1.4.1.4253.1.9.6.1.1
mcmCardShelfThe shelf of the mcmt1/mcme1 is in. Valid values are: 1..2ro
CardShelf
.1.3.6.1.4.1.4253.1.9.6.1.2
mcmCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 21 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.9.6.1.3
mcmMfgDateDate and Time of calibration of the mcmt1/mcme1 cardro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.9.6.1.4
mcmSerialNumSerial # of the mcmt1/mcme1 card.ro
SerialString
.1.3.6.1.4.1.4253.1.9.6.1.5
mcmModelTypeModel type of the mcmt1/mcme1ro
CardType
.1.3.6.1.4.1.4253.1.9.6.1.6
mcmNameDisplay (Network) name of the MCMT1/MCME1 Modulerw
CardName
.1.3.6.1.4.1.4253.1.9.6.1.7
mcmFWVersionIDThe current version string of the MCMT1/MCME1 FW codero
VersionString
.1.3.6.1.4.1.4253.1.9.6.1.8
mcmAdminStateAdministrative control over that mcmt1/mcme1 card. Default value is enable. When disabled, no alarms/events gets generated.rw
Enumeration
.1.3.6.1.4.1.4253.1.9.6.1.9
mcmLaserTemperatureTemperature of the Laser. Not yet supported
INTEGER
.1.3.6.1.4.1.4253.1.9.6.1.10
mcmBandwidthmcmt1/mcme1 module's line rate.
Enumeration
.1.3.6.1.4.1.4253.1.9.6.1.11
mcmSetStateInstruct the mcmt1/mcme1 card to do either a reset or loopback. A get on this will always return an other.rw
Enumeration
.1.3.6.1.4.1.4253.1.9.6.1.12
mcmNumPortsTotal port numbers of MCMT1/MCME1 module.ro
INTEGER
.1.3.6.1.4.1.4253.1.9.6.1.13
mcmUpgradeFlagThe MCMT1/MCME1 module's status is upgradable or not.ro
Enumeration
.1.3.6.1.4.1.4253.1.9.6.1.14
mcmEthernetStatusThe MCMT1/MCME1 module's Ethernet status is down or up.rw
Enumeration
.1.3.6.1.4.1.4253.1.9.6.1.15
mcmTimingPortThe MCMT1/MCME1 module's port clock srcro
Enumeration
.1.3.6.1.4.1.4253.1.9.6.1.16
mcmModelNumThe mcmt1/mcme1 port's model numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.9.6.1.17
mcmMfgBiasCurrentBias current for the optical laser. This is the preset manufacturing valuero
INTEGER
.1.3.6.1.4.1.4253.1.9.6.1.18
mcmMfgModulationThe frequency modulation for the optical laser. This value is the preset manufacturing value.ro
INTEGER
.1.3.6.1.4.1.4253.1.9.6.1.19
mcmMfgApcThe APC value. This value is the preset manufacturing valuero
INTEGER
.1.3.6.1.4.1.4253.1.9.6.1.20
mcmMfgIwmModulationThe frequency modulation for the IWM channel. This value is the preset manufacturing valuero
INTEGER
.1.3.6.1.4.1.4253.1.9.6.1.21
mcmconnMuxShelfThe connected mux shelf.ro
ShelfInput
.1.3.6.1.4.1.4253.1.9.6.1.22
mcmconnMuxSlotThe connected mux slot.ro
SlotInput
.1.3.6.1.4.1.4253.1.9.6.1.23
mcmconnMuxPortThe connected mux port.ro
INTEGER
.1.3.6.1.4.1.4253.1.9.6.1.24
mcmconnDemuxShelfThe connected demux shelf.ro
ShelfInput
.1.3.6.1.4.1.4253.1.9.6.1.25
mcmconnDemuxSlotThe connected demux slot.ro
SlotInput
.1.3.6.1.4.1.4253.1.9.6.1.26
mcmconnDemuxPortThe connected demux port.ro
INTEGER
.1.3.6.1.4.1.4253.1.9.6.1.27
mcmTimingPriorityThe clock source priority in descending order in the format of a,b,c,d,e,f in which a through f should be replaced with 1 through 6 which has the same meaning as the options of mcmTimingPort and are repeated as follows: 0 - unknown 1 - internal 2 - link 3 - t1Port1 4 - t1Port2 5 - t1Port3 6 - t1Port4 For example, '2,5,4,6,3,1' will set the priority of the clock source with link first, followed by t1Port3, followed by t1Port2, followed by t1Port4, followed by t1Port1, followed by internal.rw
DisplayString
.1.3.6.1.4.1.4253.1.9.6.1.28
mcmLinkNameUser configurable Link name for the connection between the local and remote MCM/MCME1 Modulesrw
LinkName
.1.3.6.1.4.1.4253.1.9.6.1.29
mcmEthernetModeThis allows the ethernet mode configured as auto detect, forced 10M, or forced 100M.rw
Enumeration
.1.3.6.1.4.1.4253.1.9.6.1.30
mcmHWNameDisplay Hardware name of the MCMT1/MCME1 Card.ro
CardName
.1.3.6.1.4.1.4253.1.9.6.1.31
mcmLinkWaveLengthLink Wavelength of the MCMT1/MCME1 cardro
DisplayString
.1.3.6.1.4.1.4253.1.9.6.1.32
mcmFpgaVersionIDThe current version string of the MCMT1/MCME1 FPGA.ro
VersionString
.1.3.6.1.4.1.4253.1.9.6.1.33
mcmPathIDUpsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.9.6.1.34
mcmCleiNumCLEI number of the mcmt1/mcme1 Card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.9.6.1.35
mcmItuNumITU number of the mcmt1/mcme1 Card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.9.6.1.36
mcmPortNumberNumber of MCMT1/MCME1 rows in the following table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.9.7
mcmPortTableThis table represents the information for each MCMT1/MCME1 module's port.
SEQUENCE OF McmPortEntry
.1.3.6.1.4.1.4253.1.9.8
mcmPortEntrySpecifies the index for each row in the table below
McmPortEntry
.1.3.6.1.4.1.4253.1.9.8.1
mcmPortCardLocationLocation of the MCMT1/MCME1 port. Valid values are: Local in the same chassis, or remote to this chassisro
CardLocation
.1.3.6.1.4.1.4253.1.9.8.1.1
mcmPortCardShelfThe shelf the card is in. Valid values are: 1..2.ro
CardShelf
.1.3.6.1.4.1.4253.1.9.8.1.2
mcmPortCardSlotThe slot within the shelf the Module is in. Valid values are: 1 to 17ro
SlotInput
.1.3.6.1.4.1.4253.1.9.8.1.3
mcmPortIndexPort's index.ro
INTEGER
.1.3.6.1.4.1.4253.1.9.8.1.4
mcmPortConnectionPort's connection status.rw
Enumeration
.1.3.6.1.4.1.4253.1.9.8.1.5
mcmPortFramingType of framing. esf(1) and d4(2) are for mcmt1. crc4(3) is for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, CRC4, hence, operation of setting will return an error.rw
Enumeration
.1.3.6.1.4.1.4253.1.9.8.1.6
mcmPortLineCodingType of line coding. b8zs(1) and ami(2) are for mcmt1. hdb3(3) is for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, HDB3, hence, operation of setting will return an error.rw
Enumeration
.1.3.6.1.4.1.4253.1.9.8.1.7
mcmPortLineEqualizerThe Line equilizer. ft0to133(1), ft133to266(2), ft266to399(3), ft399to533(4), and ft533to655(5) are for mcmt1. minus43dB(6) is for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, -43dB, hence, operation of setting will return an error.rw
Enumeration
.1.3.6.1.4.1.4253.1.9.8.1.8
mcmPortImpedancePort impedance. ohms-100(1) is for mcmt1. ohms-75(2) and ohms-120(3) are for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, 75 ohm, hence, operation of setting will return an error.ro
Enumeration
.1.3.6.1.4.1.4253.1.9.8.1.9
fn
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.10
fnNumberNumber of fn rows in the following table. This number is automatically updated whenever a new row is added to the table below.
INTEGER
.1.3.6.1.4.1.4253.1.10.1
fnTableThis table represents the information for each fn.
SEQUENCE OF FnEntry
.1.3.6.1.4.1.4253.1.10.2
fnEntrySpecifies the index for each row in the table below
FnEntry
.1.3.6.1.4.1.4253.1.10.2.1
fnIDThe slot ID the fn is in. Valid values are: 1 to 4
INTEGER
.1.3.6.1.4.1.4253.1.10.2.1.1
fnMfgDateDate and Time of manufacturing of the fn
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.10.2.1.2
fnSerialNumSerial # of the fn. Not Supported Yet.
SerialString
.1.3.6.1.4.1.4253.1.10.2.1.3
fnModelTypeModel type of the fn. Up to 10 characters. Not Supported Yet.
ModelString
.1.3.6.1.4.1.4253.1.10.2.1.4
csim
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.11
csimSysModeThe ColorSim Mode of the Chassis. The value Enable means that the ColorSim feature is enabled for all the interface cards. An action element, returns other on a get request.rw
Enumeration
.1.3.6.1.4.1.4253.1.11.1
csimTableEach entry in this table represents the information for each colorsim card.
SEQUENCE OF CsimEntry
.1.3.6.1.4.1.4253.1.11.2
csimEntrySpecifies the index for each row in the table below.
CsimEntry
.1.3.6.1.4.1.4253.1.11.2.1
csimLocationLocation of the card. Valid values are: Local in the same chassis, or remote to this chassis.ro
CardLocation
.1.3.6.1.4.1.4253.1.11.2.1.1
csimShelfThe shelf the card is in. Valid values are: 1 to 10ro
CardShelf
.1.3.6.1.4.1.4253.1.11.2.1.2
csimSlotThis card occupies two slots currently.ro
SlotInput
.1.3.6.1.4.1.4253.1.11.2.1.3
csimModeThe Mode of ColorSIM for this entry. The Modes are Enable or Disable.rw
Enumeration
.1.3.6.1.4.1.4253.1.11.2.1.4
csimDCModeThe Data Collection Mode of ColorSIM.rw
Enumeration
.1.3.6.1.4.1.4253.1.11.2.1.5
csimGatingIntvlThe Gating Interval in seconds in which the incoming data stream is being monitored for errors.rw
INTEGER
.1.3.6.1.4.1.4253.1.11.2.1.6
csimUpdtIntvlNumber of gating intervals to be processed before the data is logged for reporting purposes.rw
INTEGER
.1.3.6.1.4.1.4253.1.11.2.1.7
csimSEIThresholdThe SEI Threshold of ColorSIM specifies the maximum number of errored bits that may have occurred during a single gating interval before the interval is considered Severely Errorred. The Threshold values are in the form of x.ye-z.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.11.2.1.8
rpsm
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.12
rpsmBootPromVerThe current version string of the rpsm Boot PROM code
VersionString
.1.3.6.1.4.1.4253.1.12.1
rpsmROMSizeTotal Size of the ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.12.2
rpsmNumSubDivNumber of the subdivisions of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.12.3
rpsmSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF RpsmSubDivEntry
.1.3.6.1.4.1.4253.1.12.4
rpsmSubDivEntrySpecifies the index for each row in the table below
RpsmSubDivEntry
.1.3.6.1.4.1.4253.1.12.4.1
rpsmSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.12.4.1.1
rpsmSubDivDescrDisplay Name of each Sub Division in ROM
DisplayString
.1.3.6.1.4.1.4253.1.12.4.1.2
rpsmSubDivSizeSize of each sub division in ROM in kilobytes
INTEGER
.1.3.6.1.4.1.4253.1.12.4.1.3
rpsmSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.12.4.1.4
rpsmNumberNumber of RPSM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
INTEGER
.1.3.6.1.4.1.4253.1.12.5
rpsmTableThis table represents the information for each RPSM card
SEQUENCE OF RpsmEntry
.1.3.6.1.4.1.4253.1.12.6
rpsmEntrySpecifies the index for each row in the table below
RpsmEntry
.1.3.6.1.4.1.4253.1.12.6.1
rpsmCardLocationLocation of the RPSM card. Valid values are: Local in the same chassis, or remote to this chassis.
CardLocation
.1.3.6.1.4.1.4253.1.12.6.1.1
rpsmCardShelfThe shelf the card is in. Valid values are: 1 to 2.
CardShelf
.1.3.6.1.4.1.4253.1.12.6.1.2
rpsmCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
SlotInput
.1.3.6.1.4.1.4253.1.12.6.1.3
rpsmModelNumRPSM's model number.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.12.6.1.4
rpsmOpticsMfgDateDate and Time of manufacturing of the optics on the RPSM card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.12.6.1.5
rpsmSerialNumSerial # of the RPSM card.
SerialString
.1.3.6.1.4.1.4253.1.12.6.1.6
rpsmModelTypeModel type of the RPSM.
Enumeration
.1.3.6.1.4.1.4253.1.12.6.1.7
rpsmHWNameManufacturing Hardware name of the RPSM Card.
CardName
.1.3.6.1.4.1.4253.1.12.6.1.8
rpsmFWVersionIDThe current version string of the RPSM FW code
VersionString
.1.3.6.1.4.1.4253.1.12.6.1.9
rpsmCardNameUser configurable card name.
CardName
.1.3.6.1.4.1.4253.1.12.6.1.10
rpsmFWNameRPSM's Firmware Name.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.12.6.1.11
rpsmFWDateDate and Time of latest Firmware of the RPSM card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.12.6.1.12
rpsmHWVersionIDThe current version string of the RPSM HW code.
VersionString
.1.3.6.1.4.1.4253.1.12.6.1.13
rpsmHWDateDate and Time of Hardware of the RPSM card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.12.6.1.14
rpsmSetStateInstruct the rpsm to do a warmboot. A get on this will always return an other.
RebootType
.1.3.6.1.4.1.4253.1.12.6.1.15
rpsmExpressLossInsertion loss for the expressed channel through the RPSM module in dB.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.12.6.1.16
rpsmMarginForSwitchSwitching threshold in dB for protection switch to occur.
INTEGER (-40..0)
.1.3.6.1.4.1.4253.1.12.6.1.17
rpsmMinProtPowerForSwitchMinimum protection link's light power in dBm to allow protection switching to occur.
INTEGER (-40..0)
.1.3.6.1.4.1.4253.1.12.6.1.18
rpsmDeBounceDebounce in number of times to measure low light power before protection switch.
INTEGER
.1.3.6.1.4.1.4253.1.12.6.1.19
rpsmBlackOutTimeBlack out time in unit of 0.1 second after protection switch to allow another protection switch to occur again.
INTEGER
.1.3.6.1.4.1.4253.1.12.6.1.20
rpsmSwitchinstruct the RPSM to take on an action, such as: switch to link A or link B. A get would alway return other(1).
Enumeration
.1.3.6.1.4.1.4253.1.12.6.1.21
rpsmAddDropLossInsertion loss of the Add/Drop path through the RPSM module in dB.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.12.6.1.22
rpsmPathIDUpsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
PathIdName
.1.3.6.1.4.1.4253.1.12.6.1.23
rpsmAdminStateAdministrative control over that rpsm card. Default value is enable. When disabled, no alarms/events gets generated.
Enumeration
.1.3.6.1.4.1.4253.1.12.6.1.24
rpsmPortTableThis table represents the physical connection for each RPSM card's port.
SEQUENCE OF RpsmPortEntry
.1.3.6.1.4.1.4253.1.12.7
rpsmPortEntrySpecifies the index for each row in the table below
RpsmPortEntry
.1.3.6.1.4.1.4253.1.12.7.1
rpsmPortCardShelfThe shelf the card is in. Valid values are: 1 to 2.
CardShelf
.1.3.6.1.4.1.4253.1.12.7.1.1
rpsmPortCardSlotThe slot within the shelf the card is in.
SlotInput
.1.3.6.1.4.1.4253.1.12.7.1.2
rpsmPortTypeType of the RPSM's port. The order is CLI compatible.
Enumeration
.1.3.6.1.4.1.4253.1.12.7.1.3
rpsmConnCardTypeType of connection. Valid values are ocmu(2), ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21), osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc... A zero will be used for no connections.
INTEGER
.1.3.6.1.4.1.4253.1.12.7.1.4
rpsmConnPortConn port for RPSM's port.Possible values based on card types that can connect to RPSM are: OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN W4CM/W4CD: 1=1510, 2=1530, 3=1550, 4=1570, 5=EXP, 6=IN/OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT OSAM: 1=IN, 2=OUT FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx
INTEGER
.1.3.6.1.4.1.4253.1.12.7.1.5
rpsmConnShelfThe shelf the card conn to. Valid values are: 1 to 2.
ShelfInput
.1.3.6.1.4.1.4253.1.12.7.1.6
rpsmConnSlotThe slot within the shelf the card conn to.
SlotInput
.1.3.6.1.4.1.4253.1.12.7.1.7
rsdm
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.13
rsdmBootPromVerThe current version string of the rsdm Boot PROM code
VersionString
.1.3.6.1.4.1.4253.1.13.1
rsdmROMSizeTotal Size of the ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.13.2
rsdmNumSubDivNumber of the subdivisions of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.13.3
rsdmSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF RsdmSubDivEntry
.1.3.6.1.4.1.4253.1.13.4
rsdmSubDivEntrySpecifies the index for each row in the table below
RsdmSubDivEntry
.1.3.6.1.4.1.4253.1.13.4.1
rsdmSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.13.4.1.1
rsdmSubDivDescrDisplay Name of each Sub Division in ROM
DisplayString
.1.3.6.1.4.1.4253.1.13.4.1.2
rsdmSubDivSizeSize of each sub division in ROM in kilobytes
INTEGER
.1.3.6.1.4.1.4253.1.13.4.1.3
rsdmSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.13.4.1.4
rsdmNumberNumber of RSDM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
INTEGER
.1.3.6.1.4.1.4253.1.13.5
rsdmTableThis table represents the information for each RSDM card
SEQUENCE OF RsdmEntry
.1.3.6.1.4.1.4253.1.13.6
rsdmEntrySpecifies the index for each row in the table below
RsdmEntry
.1.3.6.1.4.1.4253.1.13.6.1
rsdmCardLocationLocation of the RSDM card. Valid values are: Local in the same chassis, or remote to this chassis.
CardLocation
.1.3.6.1.4.1.4253.1.13.6.1.1
rsdmCardShelfThe shelf the card is in. Valid values are: 1 to 2
CardShelf
.1.3.6.1.4.1.4253.1.13.6.1.2
rsdmCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
SlotInput
.1.3.6.1.4.1.4253.1.13.6.1.3
rsdmModelNumRSDM's model number.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.13.6.1.4
rsdmOpticsMfgDateDate and Time of manufacturing of the optics on the RSDM card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.13.6.1.5
rsdmSerialNumSerial # of the RSDM card.
SerialString
.1.3.6.1.4.1.4253.1.13.6.1.6
rsdmModelTypeModel type of the RSDM.
Enumeration
.1.3.6.1.4.1.4253.1.13.6.1.7
rsdmHWNameDisplay Hardware name of the RSDM Card.
CardName
.1.3.6.1.4.1.4253.1.13.6.1.8
rsdmCardNameUser configurable name of the RSDM Card.
CardName
.1.3.6.1.4.1.4253.1.13.6.1.9
rsdmFWVersionIDThe current version string of the RSDM FW code
VersionString
.1.3.6.1.4.1.4253.1.13.6.1.10
rsdmFWNameRSDM's Firmware Name.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.13.6.1.11
rsdmFWDateDate and Time of latest Firmware of the RSDM card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.13.6.1.12
rsdmHWVersionIDThe current version string of the RSDM HW code.
VersionString
.1.3.6.1.4.1.4253.1.13.6.1.13
rsdmHWDateDate and Time of Hardware of the RSDM card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.13.6.1.14
rsdmSetStateInstruct the rsdm to do a warmboot. A get on this will always return an other.
RebootType
.1.3.6.1.4.1.4253.1.13.6.1.15
rsdmRxITUNumberReceive port's ITU wavelength number.
INTEGER
.1.3.6.1.4.1.4253.1.13.6.1.16
rsdmTxITUNumberTransmit port's ITU wavelength number.
INTEGER
.1.3.6.1.4.1.4253.1.13.6.1.17
rsdmRxInsertionLossReceive port's insertion loss in dB.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.13.6.1.18
rsdmTxInsertionLossTransmit port's insertion loss in dB.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.13.6.1.19
rsdmExpressLossInsertion loss for the expressed channel through the RSDM module in dB.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.13.6.1.20
rsdmMarginForSwitchSwitching threshold in dB for protection switch to occur.
INTEGER (-40..0)
.1.3.6.1.4.1.4253.1.13.6.1.21
rsdmMinProtPowerForSwitchMinimum protection link's light power in dBm to allow protection switching to occur.
INTEGER (-40..0)
.1.3.6.1.4.1.4253.1.13.6.1.22
rsdmDeBounceDebounce in number of times to measure low light power before protection switch.
INTEGER
.1.3.6.1.4.1.4253.1.13.6.1.23
rsdmBlackOutTimeBlack out time in unit of 0.1 second after protection switch to allow another protection switch to occur again.
INTEGER
.1.3.6.1.4.1.4253.1.13.6.1.24
rsdmSwitchInstruct the RSDM to take on an action, such as: switch to link A or link B. A snmp get would always return other(1).
Enumeration
.1.3.6.1.4.1.4253.1.13.6.1.25
rsdmPathIDUpsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
PathIdName
.1.3.6.1.4.1.4253.1.13.6.1.26
rsdmAdminStateAdministrative control over that rsdm card. Default value is enable. When disabled, no alarms/events gets generated.
Enumeration
.1.3.6.1.4.1.4253.1.13.6.1.27
rsdmPortTableThis table represents the physical connection for each RSDM card's port.
SEQUENCE OF RsdmPortEntry
.1.3.6.1.4.1.4253.1.13.7
rsdmPortEntrySpecifies the index for each row in the table below
RsdmPortEntry
.1.3.6.1.4.1.4253.1.13.7.1
rsdmPortCardShelfThe shelf the card is in. Valid values are: 1 to 2.
CardShelf
.1.3.6.1.4.1.4253.1.13.7.1.1
rsdmPortCardSlotThe slot within the shelf the card is in.
SlotInput
.1.3.6.1.4.1.4253.1.13.7.1.2
rsdmPortTypeType of the RSDM's port. The order is CLI compatible.
Enumeration
.1.3.6.1.4.1.4253.1.13.7.1.3
rsdmConnCardTypeType of connection. Valid values are ocmu(2), ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21), osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc... A zero will be used for no connections.
CardType
.1.3.6.1.4.1.4253.1.13.7.1.4
rsdmConnPortConn port for RSDM's port.Possible values based on card types that can connect to RSDM are: OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN W4CM/W4CD: 1=1510, 2=1530, 3=1550, 4=1570, 5=EXP, 6=IN/OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT OSAM: 1=IN, 2=OUT FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx
INTEGER
.1.3.6.1.4.1.4253.1.13.7.1.5
rsdmConnShelfThe shelf the card conn to. Valid values are: 1 to 2.
ShelfInput
.1.3.6.1.4.1.4253.1.13.7.1.6
rsdmConnSlotThe slot within the shelf the card conn to.
SlotInput
.1.3.6.1.4.1.4253.1.13.7.1.7
rtdm
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.14
rtdmBootPromVerThe current version string of the RTDM Boot PROM code
VersionString
.1.3.6.1.4.1.4253.1.14.1
rtdmROMSizeTotal Size of the ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.14.2
rtdmNumSubDivNumber of the subdivisions of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.14.3
rtdmSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF RtdmSubDivEntry
.1.3.6.1.4.1.4253.1.14.4
rtdmSubDivEntrySpecifies the index for each row in the table below
RtdmSubDivEntry
.1.3.6.1.4.1.4253.1.14.4.1
rtdmSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.14.4.1.1
rtdmSubDivDescrDisplay Name of each Sub Division in ROM
DisplayString
.1.3.6.1.4.1.4253.1.14.4.1.2
rtdmSubDivSizeSize of each sub division in ROM in kilobytes
INTEGER
.1.3.6.1.4.1.4253.1.14.4.1.3
rtdmSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.14.4.1.4
rtdmNumberNumber of RTDM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
INTEGER
.1.3.6.1.4.1.4253.1.14.5
rtdmTableThis table represents the information for each RTDM card
SEQUENCE OF RtdmEntry
.1.3.6.1.4.1.4253.1.14.6
rtdmEntrySpecifies the index for each row in the table below
RtdmEntry
.1.3.6.1.4.1.4253.1.14.6.1
rtdmCardLocationLocation of the RTDM card. Valid values are: Local in the same chassis, or remote to this chassis
CardLocation
.1.3.6.1.4.1.4253.1.14.6.1.1
rtdmCardShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.1.14.6.1.2
rtdmCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
SlotInput
.1.3.6.1.4.1.4253.1.14.6.1.3
rtdmModelNumModel number for RTDM.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.14.6.1.4
rtdmOpticsMfgDateDate and Time of manufacturing of the optics on the RTDM card
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.14.6.1.5
rtdmSerialNumSerial # of the RTDM card.
SerialString
.1.3.6.1.4.1.4253.1.14.6.1.6
rtdmModelTypeModel type of the RTDM
Enumeration
.1.3.6.1.4.1.4253.1.14.6.1.7
rtdmHWNameDisplay (Network) name of the RTDM Card
CardName
.1.3.6.1.4.1.4253.1.14.6.1.8
rtdmFWVersionIDThe current version string of the RTDM FW code
VersionString
.1.3.6.1.4.1.4253.1.14.6.1.9
rtdmCardNameUser configurable card name.
CardName
.1.3.6.1.4.1.4253.1.14.6.1.10
rtdmFWNameRTDM's Firmware Name.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.14.6.1.11
rtdmFWDateDate and Time of latest Firmware of the RTDM card
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.14.6.1.12
rtdmHWVersionIDThe current version string of the RTDM HW code
VersionString
.1.3.6.1.4.1.4253.1.14.6.1.13
rtdmHWDateDate and Time of Hardware of the RTDM card
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.14.6.1.14
rtdmSetStateInstruct the rtdm to do a warmboot. A get on this will always return an other.
RebootType
.1.3.6.1.4.1.4253.1.14.6.1.15
rtdmCommonEInsertionLossThe RTDM Common path East's insertion loss in dB.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.14.6.1.16
rtdmCommonWInsertionLossThe RTDM Common path West's insertion loss in dB.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.14.6.1.17
rtdmMonEastInsertionLossThe RTDM Monitor East Path's insertion loss in dB.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.14.6.1.18
rtdmMonWestInsertionLossThe RTDM Monitor West Path's insertion loss in dB.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.14.6.1.19
rtdmPathIDUpsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
PathIdName
.1.3.6.1.4.1.4253.1.14.6.1.20
rtdmAdminStateAdministrative control over that rtdm card. Default value is enable. When disabled, no alarms/events gets generated.
Enumeration
.1.3.6.1.4.1.4253.1.14.6.1.21
rtdmPortTableThis table represents the physical connection for each RTDM card's port.
SEQUENCE OF RtdmPortEntry
.1.3.6.1.4.1.4253.1.14.7
rtdmPortEntrySpecifies the index for each row in the table below
RtdmPortEntry
.1.3.6.1.4.1.4253.1.14.7.1
rtdmPortCardShelfThe shelf the card is in. Valid values are: 1 to 2.
CardShelf
.1.3.6.1.4.1.4253.1.14.7.1.1
rtdmPortCardSlotThe slot within the shelf the card is in.
SlotInput
.1.3.6.1.4.1.4253.1.14.7.1.2
rtdmPortTypeType of the RTDM's port. The order is CLI compatible.
Enumeration
.1.3.6.1.4.1.4253.1.14.7.1.3
rtdmConnCardTypeType of connection. Valid values are ocmu(2), ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21), osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc...
INTEGER
.1.3.6.1.4.1.4253.1.14.7.1.4
rtdmConnPortConn port for RTDM's port.Possible values based on card types that can connect to RTDM are: OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN W4CM/W4CD: 1=1510, 2=1530, 3=1550, 4=1570, 5=EXP, 6=IN/OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT OSAM: 1=IN, 2=OUT FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx
INTEGER
.1.3.6.1.4.1.4253.1.14.7.1.5
rtdmConnShelfThe shelf the card conn to. Valid values are: 1 to 2.
ShelfInput
.1.3.6.1.4.1.4253.1.14.7.1.6
rtdmConnSlotThe slot within the shelf the card conn to. A zero will be used for no connections.
SlotInput
.1.3.6.1.4.1.4253.1.14.7.1.7
osam
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.15
osamBootPromVerThe current version string of the osam boot prom code.
VersionString
.1.3.6.1.4.1.4253.1.15.1
osamROMSizeTotal Size of the ROM in Kilobytes.
INTEGER
.1.3.6.1.4.1.4253.1.15.2
osamNumSubDivNumber of the ROM's subdivisions.
INTEGER
.1.3.6.1.4.1.4253.1.15.3
osamSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF OsamSubDivEntry
.1.3.6.1.4.1.4253.1.15.4
osamSubDivEntrySpecifies the index for each row in the table below
OsamSubDivEntry
.1.3.6.1.4.1.4253.1.15.4.1
osamSubDivIndexInteger ID of each subdivision.
INTEGER
.1.3.6.1.4.1.4253.1.15.4.1.1
osamSubDivDescrDisplay name of each subdivision.
DisplayString
.1.3.6.1.4.1.4253.1.15.4.1.2
osamSubDivSizeSize of each subdivision in Kbytes.
INTEGER
.1.3.6.1.4.1.4253.1.15.4.1.3
osamSubDivOffsetStarting address of each sub division in HEX format.
OCTET STRING
.1.3.6.1.4.1.4253.1.15.4.1.4
osamNumberNumber of rows in the osam table.ro
INTEGER
.1.3.6.1.4.1.4253.1.15.5
osamTableThis table represents the information for each osam card
SEQUENCE OF OsamEntry
.1.3.6.1.4.1.4253.1.15.6
osamEntrySpecifies the index for each row in the table below
OsamEntry
.1.3.6.1.4.1.4253.1.15.6.1
osamCardLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.15.6.1.1
osamCardShelfThe shelf number in which the module is plugged in.ro
CardShelf
.1.3.6.1.4.1.4253.1.15.6.1.2
osamCardSlotThe slot number in which the module is plugged in. If a 0 is written into this mib element, the module will be deleted from the system.rw
INTEGER
.1.3.6.1.4.1.4253.1.15.6.1.3
osamModelNumManufacturing model number of the module.ro
ModelNum
.1.3.6.1.4.1.4253.1.15.6.1.4
osamSerialNumUnique serial number of the module.ro
SerialString
.1.3.6.1.4.1.4253.1.15.6.1.5
osamModelTypeModel type of the module.ro
CardType
.1.3.6.1.4.1.4253.1.15.6.1.6
osamHWNameManufacturing Hardware name of the module.ro
CardName
.1.3.6.1.4.1.4253.1.15.6.1.7
osamHWVersionIDThe current hardware version string of the module.ro
VersionString
.1.3.6.1.4.1.4253.1.15.6.1.8
osamHWDateDate of manufacturing of the electronics portion of the module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.15.6.1.9
osamFWNameManufacturing Firmware name of the module.ro
CardName
.1.3.6.1.4.1.4253.1.15.6.1.10
osamFWVersionIDThe current firmware version string of the module.ro
VersionString
.1.3.6.1.4.1.4253.1.15.6.1.11
osamFWDateRelease date for the firmware of the module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.15.6.1.12
osamCardNameUser configurable card name for the module.rw
CardName
.1.3.6.1.4.1.4253.1.15.6.1.13
osamSetStateInstruct the osam module to do a reset. A get on this will always return other.rw
RebootType
.1.3.6.1.4.1.4253.1.15.6.1.14
osamLaserStateThe operational state of the laser.ro
FlagType
.1.3.6.1.4.1.4253.1.15.6.1.15
osamOperationModeOperation mode of the module. powerControlled(3) is not supported by OSAM modules. currentControlled(1) is not supported OSAM-HP/LP modules.rw
Enumeration
.1.3.6.1.4.1.4253.1.15.6.1.16
osamLaserBiasCurrentConstant current in mA to be used by the module when the operation mode is set to currentControlled. This value can't be set if operation mode is set to gainControlled. Applicable only to OSAM modulerw
INTEGER
.1.3.6.1.4.1.4253.1.15.6.1.17
osamAmplifierGainConstant gain in dB to be used by the module when the operation mode is set to gainControlled. This value can't be set if operation mode is set to currentControlled. Not applicable to OSAM-HP/LP modulerw
INTEGER
.1.3.6.1.4.1.4253.1.15.6.1.18
osamConfigCommitThis allows the current module configuration to be stored in permanent storage.rw
Enumeration
.1.3.6.1.4.1.4253.1.15.6.1.19
osamNoiseFigureThe calibrated noise figure of the gain block in dB. Applicable only to OSAM modulero
INTEGER
.1.3.6.1.4.1.4253.1.15.6.1.20
osamPathIDUpsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.15.6.1.21
osamAdminStateAdministrative control over that osam card. Default value is enable. When disabled, no alarms/events gets generated.rw
Enumeration
.1.3.6.1.4.1.4253.1.15.6.1.22
osam2NoiseFigureThe calibrated noise figure of the gain block in dBm. Applicable only to OSAM-HP/LP modulero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.15.6.1.23
osam2GainReqConstant gain in dB to be used by the module when the operation mode is set to gainControlled. This value can't be set if operation mode is set to powerControlled. Range is 0-16.5db(LP) and 0-23.3db(HP) Applicable only to OSAM-HP/LP modulerw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.15.6.1.24
osam2OpPowerReqConstant output power in dBm to be used by the module when the operation mode is set to powerControlled. This value can't be set if operation mode is set to gainControlled. Range is 0-9dbm (LP) and 0-18dbm(HP) Applicable only to OSAM-HP/LP modulerw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.15.6.1.25
osamCleiNumCLEI number of the osam Card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.15.6.1.26
osamNumPortsTotal port numbers on each OSAM card.ro
INTEGER
.1.3.6.1.4.1.4253.1.15.6.1.27
osamPortTableThis table represents the physical connection for each OSAM card's port.
SEQUENCE OF OsamPortEntry
.1.3.6.1.4.1.4253.1.15.7
osamPortEntrySpecifies the index for each row in the table below
OsamPortEntry
.1.3.6.1.4.1.4253.1.15.7.1
osamPortCardShelfThe shelf the card is in. Valid values are: 1 to 2.ro
CardShelf
.1.3.6.1.4.1.4253.1.15.7.1.1
osamPortCardSlotThe slot within the shelf the card is in.ro
SlotInput
.1.3.6.1.4.1.4253.1.15.7.1.2
osamPortTypeType of the OSAM's port.rw
Enumeration
.1.3.6.1.4.1.4253.1.15.7.1.3
osamConnCardTypeModule type connectioned to osam port.rw
CardType
.1.3.6.1.4.1.4253.1.15.7.1.4
osamConnPortConn port for OSAM's port. Possible values based on card types that can be connected to OSAM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.rw
INTEGER
.1.3.6.1.4.1.4253.1.15.7.1.5
osamConnShelfThe shelf the card conn to. Valid values are: 1 to 2.rw
ShelfInput
.1.3.6.1.4.1.4253.1.15.7.1.6
osamConnSlotThe slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.15.7.1.7
osamPortCardTypeType of OSAM module.ro
CardType
.1.3.6.1.4.1.4253.1.15.7.1.8
osamConnLocationThe chassis's location of the card connected to.ro
CardLocation
.1.3.6.1.4.1.4253.1.15.7.1.9
osamConnChassisIDChassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.15.7.1.10
osamConnSystemNameSystem Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.15.7.1.11
osamConnIpAddressIpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node.ro
IpAddress
.1.3.6.1.4.1.4253.1.15.7.1.12
rsm
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.16
rsmBootPromVerThe current version string of the rsm Boot PROM code
VersionString
.1.3.6.1.4.1.4253.1.16.1
rsmROMSizeTotal Size of the ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.16.2
rsmNumSubDivNumber of the subdivisions of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.16.3
rsmSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF RsmSubDivEntry
.1.3.6.1.4.1.4253.1.16.4
rsmSubDivEntrySpecifies the index for each row in the table below
RsmSubDivEntry
.1.3.6.1.4.1.4253.1.16.4.1
rsmSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.16.4.1.1
rsmSubDivDescrDisplay Name of each Sub Division in ROM
DisplayString
.1.3.6.1.4.1.4253.1.16.4.1.2
rsmSubDivSizeSize of each sub division in ROM in kilobytes
INTEGER
.1.3.6.1.4.1.4253.1.16.4.1.3
rsmSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.16.4.1.4
rsmNumberNumber of RSM rows in the following table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.16.5
rsmTableThis table represents the information for each RSM card
SEQUENCE OF RsmEntry
.1.3.6.1.4.1.4253.1.16.6
rsmEntrySpecifies the index for each row in the table below
RsmEntry
.1.3.6.1.4.1.4253.1.16.6.1
rsmCardLocationLocation of the RSM card. Valid values are: Local in the same chassis.ro
CardLocation
.1.3.6.1.4.1.4253.1.16.6.1.1
rsmCardShelfThe shelf the card is in. Valid values are: 1 to 2.ro
CardShelf
.1.3.6.1.4.1.4253.1.16.6.1.2
rsmCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.16.6.1.3
rsmModelNumRSM's model number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.16.6.1.4
rsmOpticsMfgDateDate and Time of manufacturing of the optics on the RSM card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.16.6.1.5
rsmSerialNumSerial # of the RSM card.ro
SerialString
.1.3.6.1.4.1.4253.1.16.6.1.6
rsmModelTypeModel type of the RSM.ro
CardType
.1.3.6.1.4.1.4253.1.16.6.1.7
rsmHWNameManufacturing Hardware name of the RSM Card.ro
CardName
.1.3.6.1.4.1.4253.1.16.6.1.8
rsmCardNameUser configurable card name.rw
CardName
.1.3.6.1.4.1.4253.1.16.6.1.9
rsmFWNameRSM's Firmware Name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.16.6.1.10
rsmFWVersionIDThe current version string of the RSM FW code.ro
VersionString
.1.3.6.1.4.1.4253.1.16.6.1.11
rsmFWDateDate and Time of latest Firmware of the RSM card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.16.6.1.12
rsmSetStateInstruct the rsm to do a warmboot. A get on this will always return an other.rw
RebootType
.1.3.6.1.4.1.4253.1.16.6.1.13
rsmRxInsertionLossInsertion loss for Rx Path.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.16.6.1.14
rsmRxComInsertionLossInsertion loss for Rx Com Path.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.16.6.1.15
rsmWorkingWavelengthThe RSM ITU number.ro
INTEGER
.1.3.6.1.4.1.4253.1.16.6.1.16
rsmLinkAPathIDRsm LinkA Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.16.6.1.17
rsmLinkBPathIDRsm LinkB Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.16.6.1.18
rsmAdminStateAdministrative control over that rsm card. Default value is enable. When disabled, no alarms/events gets generated.rw
Enumeration
.1.3.6.1.4.1.4253.1.16.6.1.19
rsmCleiNumCLEI number of the rsm Card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.16.6.1.20
rsmNumPortsTotal port numbers on each RSM card.ro
INTEGER
.1.3.6.1.4.1.4253.1.16.6.1.21
rsmPortTableThis table represents the information for each RSM card's port.
SEQUENCE OF RsmPortEntry
.1.3.6.1.4.1.4253.1.16.7
rsmPortEntrySpecifies the index for each row in the table below
RsmPortEntry
.1.3.6.1.4.1.4253.1.16.7.1
rsmPortCardShelfThe shelf the card is in. Valid values are: 1 to 2.ro
CardShelf
.1.3.6.1.4.1.4253.1.16.7.1.1
rsmPortCardSlotThe slot within the shelf the card is in.ro
SlotInput
.1.3.6.1.4.1.4253.1.16.7.1.2
rsmPortTypeType of the RSM's port. The order is CLI compatible.ro
Enumeration
.1.3.6.1.4.1.4253.1.16.7.1.3
rsmConnCardTypeModule type connected to rsm port. The valid module types are OCM10G/OCME/OCMITU/OCMU.rw
CardType
.1.3.6.1.4.1.4253.1.16.7.1.4
rsmConnShelfThe shelf the card conn to. Valid values are: 1 to 2.rw
ShelfInput
.1.3.6.1.4.1.4253.1.16.7.1.5
rsmConnSlotThe slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.16.7.1.6
rsmConnPortConn port for RSM's port. Only OCM10G/OCME/OCMITU/OCMU can be connected to RSM. The possible values are: OCM10G/OCME/OCMITU/OCMU: 3=CPE Tx, 4=CPE Rxrw
INTEGER
.1.3.6.1.4.1.4253.1.16.7.1.7
upsm
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.17
upsmBootPromVerThe current version string of the rsm Boot PROM code
VersionString
.1.3.6.1.4.1.4253.1.17.1
upsmROMSizeTotal Size of the ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.17.2
upsmNumSubDivNumber of the subdivisions of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.17.3
upsmSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF UpsmSubDivEntry
.1.3.6.1.4.1.4253.1.17.4
upsmSubDivEntrySpecifies the index for each row in the table below
UpsmSubDivEntry
.1.3.6.1.4.1.4253.1.17.4.1
upsmSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.17.4.1.1
upsmSubDivDescrDisplay Name of each Sub Division in ROM
DisplayString
.1.3.6.1.4.1.4253.1.17.4.1.2
upsmSubDivSizeSize of each sub division in ROM in kilobytes
INTEGER
.1.3.6.1.4.1.4253.1.17.4.1.3
upsmSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.17.4.1.4
upsmNumberNumber of UPSM rows in the following table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.17.5
upsmTableThis table represents the information for each UPSM card
SEQUENCE OF UpsmEntry
.1.3.6.1.4.1.4253.1.17.6
upsmEntrySpecifies the index for each row in the table below
UpsmEntry
.1.3.6.1.4.1.4253.1.17.6.1
upsmCardLocationLocation of the UPSM card. Valid values are: Local in the same chassis.ro
CardLocation
.1.3.6.1.4.1.4253.1.17.6.1.1
upsmCardShelfThe shelf the card is in. Valid values are: 1 to 2.ro
INTEGER
.1.3.6.1.4.1.4253.1.17.6.1.2
upsmCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.rw
INTEGER
.1.3.6.1.4.1.4253.1.17.6.1.3
upsmModelNumUPSM's model number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.17.6.1.4
upsmOpticsMfgDateDate and Time of manufacturing of the optics on the UPSM card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.17.6.1.5
upsmSerialNumSerial # of the UPSM card.ro
SerialString
.1.3.6.1.4.1.4253.1.17.6.1.6
upsmModelTypeModel type of the UPSM.ro
CardType
.1.3.6.1.4.1.4253.1.17.6.1.7
upsmHWNameManufacturing Hardware name of the UPSM Card.ro
CardName
.1.3.6.1.4.1.4253.1.17.6.1.8
upsmCardNameUser configurable card name.rw
CardName
.1.3.6.1.4.1.4253.1.17.6.1.9
upsmFWNameUPSM's Firmware Name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.17.6.1.10
upsmFWVersionIDThe current version string of the UPSM FW code.ro
VersionString
.1.3.6.1.4.1.4253.1.17.6.1.11
upsmFWDateDate and Time of latest Firmware of the UPSM card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.17.6.1.12
upsmSetStateInstruct the upsm to do a warmboot. A get on this will always return an other.rw
RebootType
.1.3.6.1.4.1.4253.1.17.6.1.13
upsmRxInsertionLossInsertion loss for Rx Path.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.17.6.1.14
upsmTxInsertionLossInsertion loss for Tx Path.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.17.6.1.15
upsmMarginForSwitchThe UPSM switching threshold for protection switch to occur. The limit is from -32 to -6. Switching threshold must be 1 dBm or more less than the minimum switch power.rw
INTEGER (-32..-6)
.1.3.6.1.4.1.4253.1.17.6.1.16
upsmMinProtPowerForSwitchThe minimum protection link power to allow protection switch to function. The limit is from -30 to -5. This value should be 1 dBm or more greater than the switch margin.rw
INTEGER (-30..-5)
.1.3.6.1.4.1.4253.1.17.6.1.17
upsmDebounceThe number of times to measure low power condition before performing protection switch.ro
INTEGER
.1.3.6.1.4.1.4253.1.17.6.1.18
upsmBlackOutTimeThe time after protection switch before allowing another protection switch.ro
INTEGER
.1.3.6.1.4.1.4253.1.17.6.1.19
upsmSwitchThe Link switch control. switchToLinkA or switchToLinkB option would disable auto switch functionality. Auto switch functionality can be turned on by setting to enableAutoSwitch optionrw
Enumeration
.1.3.6.1.4.1.4253.1.17.6.1.20
upsmLinkAPathIDUpsm LinkA Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.17.6.1.21
upsmLinkBPathIDUpsm LinkB Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.17.6.1.22
upsmAdminStateAdministrative control over that upsm card. Default value is enable. When disabled, no alarms/events gets generated.rw
Enumeration
.1.3.6.1.4.1.4253.1.17.6.1.23
upsmCleiNumCLEI number of the upsm Card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.17.6.1.24
upsmSwitchStateThe switching state. Switching state may be either auto or forced. The auto state means automatic switching is enabled. Forced state means swithcing is disabled and has been forced to the current active link.ro
Enumeration
.1.3.6.1.4.1.4253.1.17.6.1.25
upsmNumPortsTotal port numbers on each UPSM card.ro
INTEGER
.1.3.6.1.4.1.4253.1.17.6.1.26
upsmPortTableThis table represents the information for each UPSM card's port.
SEQUENCE OF UpsmPortEntry
.1.3.6.1.4.1.4253.1.17.7
upsmPortEntrySpecifies the index for each row in the table below
UpsmPortEntry
.1.3.6.1.4.1.4253.1.17.7.1
upsmPortCardShelfThe shelf the card is in. Valid values are: 1 to 2.ro
CardShelf
.1.3.6.1.4.1.4253.1.17.7.1.1
upsmPortCardSlotThe slot within the shelf the card is in.ro
SlotInput
.1.3.6.1.4.1.4253.1.17.7.1.2
upsmPortTypeType of the UPSM's port. The order is CLI compatible.ro
Enumeration
.1.3.6.1.4.1.4253.1.17.7.1.3
upsmConnLocationThe chassis's location of the card conn to.rw
CardLocation
.1.3.6.1.4.1.4253.1.17.7.1.4
upsmConnIpAddressIpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the noderw
IpAddress
.1.3.6.1.4.1.4253.1.17.7.1.5
upsmConnChassisIDChassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local noderw
DisplayString
.1.3.6.1.4.1.4253.1.17.7.1.6
upsmConnSystemNameSystem Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node.rw
DisplayString
.1.3.6.1.4.1.4253.1.17.7.1.7
upsmConnCardTypeModule type connected to upsm port.rw
CardType
.1.3.6.1.4.1.4253.1.17.7.1.8
upsmConnPortConn port for UPSM's port. Possible values based on card types that can connect to UPSM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.rw
INTEGER
.1.3.6.1.4.1.4253.1.17.7.1.9
upsmConnShelfThe shelf the card conn to. Valid values are: 1 to 2.rw
ShelfInput
.1.3.6.1.4.1.4253.1.17.7.1.10
upsmConnSlotThe slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.17.7.1.11
mcmesc
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.18
mcmescBootPromVerThe current version string of the mcmesc Boot PROM code
VersionString
.1.3.6.1.4.1.4253.1.18.1
mcmescROMSizeTotal Size of the ROM in Kilobyes
INTEGER
.1.3.6.1.4.1.4253.1.18.2
mcmescNumSubDivNumber of the subdivisions of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.18.3
mcmescSubDivTableThis table represents the number of sub divisions and the size of each subdivision in ROM memory
SEQUENCE OF McmescSubDivEntry
.1.3.6.1.4.1.4253.1.18.4
mcmescSubDivEntrySpecifies the index for each row in the table below
McmescSubDivEntry
.1.3.6.1.4.1.4253.1.18.4.1
mcmescSubDivIndexInteger ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
INTEGER
.1.3.6.1.4.1.4253.1.18.4.1.1
mcmescSubDivDescrDisplay Name of each Sub Division in ROM
DisplayString
.1.3.6.1.4.1.4253.1.18.4.1.2
mcmescSubDivSizeSize of each sub division in ROM in kilobytes
INTEGER
.1.3.6.1.4.1.4253.1.18.4.1.3
mcmescSubDivOffsetStarting address of each sub division in the ROM in HEX notation.
OCTET STRING
.1.3.6.1.4.1.4253.1.18.4.1.4
mcmescNumberNumber of rows in the following table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.18.5
mcmescTableThis table represents the information for each mcmesc module
SEQUENCE OF McmescEntry
.1.3.6.1.4.1.4253.1.18.6
mcmescEntrySpecifies the index for each row in the table below
McmescEntry
.1.3.6.1.4.1.4253.1.18.6.1
mcmescCardLocationLocation of the mcmesc Module.ro
CardLocation
.1.3.6.1.4.1.4253.1.18.6.1.1
mcmescCardShelfThe shelf of the mcmesc is in. Valid values are: 1..2ro
CardShelf
.1.3.6.1.4.1.4253.1.18.6.1.2
mcmescCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.18.6.1.3
mcmescMfgDateDate and Time of calibration of the mcmesc cardro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.18.6.1.4
mcmescSerialNumSerial # of the mcmesc card.ro
SerialString
.1.3.6.1.4.1.4253.1.18.6.1.5
mcmescModelTypeModel type of the mcmescro
CardType
.1.3.6.1.4.1.4253.1.18.6.1.6
mcmescModelNumModel number of the MCMESC card. Up to 15 charactersro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.18.6.1.7
mcmescNameDisplay (Network) name of the MCMESC Modulerw
CardName
.1.3.6.1.4.1.4253.1.18.6.1.8
mcmescHWNameDisplay Hardware name of the MCMESC Card.ro
CardName
.1.3.6.1.4.1.4253.1.18.6.1.9
mcmescNumPortsTotal port numbers of MCM module.ro
INTEGER
.1.3.6.1.4.1.4253.1.18.6.1.10
mcmescFWVersionIDThe current version string of the MCMESC FW codero
VersionString
.1.3.6.1.4.1.4253.1.18.6.1.11
mcmesc2ndFWVersionIDThe version string of the MCMESC second FW codero
VersionString
.1.3.6.1.4.1.4253.1.18.6.1.12
mcmescFPGAVersionIDThe current version string of the MCMESC FPGA codero
VersionString
.1.3.6.1.4.1.4253.1.18.6.1.13
mcmesc2ndFPGAVersionIDThe version string of the MCMESC second FPGA codero
VersionString
.1.3.6.1.4.1.4253.1.18.6.1.14
mcmescBoardSerialNumSerial # of the MCMESC board.ro
SerialString
.1.3.6.1.4.1.4253.1.18.6.1.15
mcmescBoardVersionIDThe version string of the MCMESC boardro
VersionString
.1.3.6.1.4.1.4253.1.18.6.1.16
mcmescDaughterBoard1SerialNumSerial # of the MCMESC daughter board 1.ro
SerialString
.1.3.6.1.4.1.4253.1.18.6.1.17
mcmescDaughterBoard1VersionIDThe version string of the MCMESC daughter board 1ro
VersionString
.1.3.6.1.4.1.4253.1.18.6.1.18
mcmescDaughterBoard2SerialNumSerial # of the MCMESC daughter board 2.ro
SerialString
.1.3.6.1.4.1.4253.1.18.6.1.19
mcmescDaughterBoard2VersionIDThe version string of the MCMESC daughter board 2ro
VersionString
.1.3.6.1.4.1.4253.1.18.6.1.20
mcmescCleiNumCLEI number of the MCMESC Card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.18.6.1.21
mcmescLinkWavelengthLink Wavelength of the MCMESC cardro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.18.6.1.22
mcmescLinkSfpSerialNumLink port's SFP serial number.ro
SfpSerialString
.1.3.6.1.4.1.4253.1.18.6.1.23
mcmescAdminStateAdministrative control over that MCMESC card. Default value is enable. When disabled, no alarms/events gets generated.rw
Enumeration
.1.3.6.1.4.1.4253.1.18.6.1.24
mcmescLinkNameLink name for fiber between the local and the remote MCMESC card.rw
LinkName
.1.3.6.1.4.1.4253.1.18.6.1.25
mcmescPathIDUpsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.18.6.1.26
mcmescOverrideMPM overrides the settings stored on MCMESC card upon detecting it. Default value is no. Not applicable to remote MCMESC.rw
Enumeration
.1.3.6.1.4.1.4253.1.18.6.1.27
mcmescPerfIntervalThe interval, in seconds, in which MCMESC collects the performance data, ranging 60 to 3600.rw
INTEGER
.1.3.6.1.4.1.4253.1.18.6.1.28
mcmescCpeRxSigLowThresholdThe threshold of reporting CPE port Rx signal low alarm, in dBm, ranging from -29 to -7.rw
INTEGER (-29..-7)
.1.3.6.1.4.1.4253.1.18.6.1.29
mcmescLinkRxSigLowThresholdThe threshold of reporting Link Rx signal low alarm, in dBm, ranging from -29 to -7.rw
INTEGER (-29..-7)
.1.3.6.1.4.1.4253.1.18.6.1.30
mcmescCpeErrEventThresholdThe threshold of reporting CPE error event, in the form of 1.0E-x. Only x needs to be set and will be read. The range of x is from 5 to 15, however, input should be an absolute value if using mib browser. This threshold should be lower than the value of mcmescCpeErrAlarmThreshold, i.e., the absolute value should be higher than of mcmescCpeErrAlarmThreshold.rw
INTEGER
.1.3.6.1.4.1.4253.1.18.6.1.31
mcmescCpeErrAlarmThresholdThe threshold of reporting CPE error alarm, in the form of 1.0E-x. The range of x is from 4 to 14, however, input should be an absolute value if using mib browser. This threshold should be higher than the value of mcmescCpeErrEventThreshold, i.e., the absolute value should be lower than of mcmescCpeErrEventThreshold.rw
INTEGER
.1.3.6.1.4.1.4253.1.18.6.1.32
mcmescLinkErrEventThresholdThe threshold of reporting LINK error event, in the form of 1.0E-x. The range of x is from 5 to 15, however, input should be an absolute value if using mib browser. This threshold should be lower than the value of mcmescLinkErrAlarmThreshold, i.e., the absolute value should be higher than of mcmescLinkErrAlarmThreshold.rw
INTEGER
.1.3.6.1.4.1.4253.1.18.6.1.33
mcmescLinkErrAlarmThresholdThe threshold of reporting LINK error alarm, in the form of 1.0E-x. The range of x is from 4 to 14, however, input should be an absolute value if using mib browser. This threshold should be higher than the value of mcmescLinkErrEventThreshold, i.e., the absolute value should be lower than of mcmescLinkErrEventThreshold.rw
INTEGER
.1.3.6.1.4.1.4253.1.18.6.1.34
mcmescTestSequenceTurn on or off the test-sequence on link. The operation will take place on the remote MCMESC if it's connected.rw
FlagType
.1.3.6.1.4.1.4253.1.18.6.1.35
mcmescConnMuxShelfThe connected W4CM/UPSM shelf.ro
ShelfInput
.1.3.6.1.4.1.4253.1.18.6.1.36
mcmescConnMuxSlotThe connected W4CM/UPSM slot.ro
SlotInput
.1.3.6.1.4.1.4253.1.18.6.1.37
mcmescConnMuxPortThe connected W4CM/UPSM port. W4CM: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT; UPSM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.ro
INTEGER
.1.3.6.1.4.1.4253.1.18.6.1.38
mcmescConnDemuxShelfThe connected W4CD/UPSM shelf.ro
ShelfInput
.1.3.6.1.4.1.4253.1.18.6.1.39
mcmescConnDemuxSlotThe connected W4CD/UPSM slot.ro
SlotInput
.1.3.6.1.4.1.4253.1.18.6.1.40
mcmescConnDemuxPortThe connected W4CD/UPSM port. W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT; UPSM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.ro
INTEGER
.1.3.6.1.4.1.4253.1.18.6.1.41
mcmescConnTxOcmShelfThe connected OCM shelf (from MCMESC's Link Tx).ro
ShelfInput
.1.3.6.1.4.1.4253.1.18.6.1.42
mcmescConnTxOcmSlotThe connected OCM slot (from MCMESC's Link Tx).ro
SlotInput
.1.3.6.1.4.1.4253.1.18.6.1.43
mcmescConnTxOcmPortThe connected OCM port (from MCMESC's Link Tx). 3=OCM's CPE-Tx, 4=OCM's Rx. Only 4 is valid.ro
Enumeration
.1.3.6.1.4.1.4253.1.18.6.1.44
mcmescConnTxOcmShelfSlotAdd a connection from MCMESC Link-Tx to an OCM CPE-Rx by specifying the OCM's shelf and slot. The format is shlef,slot. If either MCMESC Link-Tx or specified OCM CPE-Rx has already had connection, an error will be returned. If the card specified by shelf,slot is not ocm type, an error will be returned. A get on this variable will always return 0,0.rw
DisplayString
.1.3.6.1.4.1.4253.1.18.6.1.45
mcmescConnTxOcmDeleteDelete a connection from MCMESC Link-Tx to an OCM CPE-Rx. If MCMESC's Link-Tx has no connection with any OCM's CPE-Rx, an error will be returned. A get on this variable will always return an other.rw
Enumeration
.1.3.6.1.4.1.4253.1.18.6.1.46
mcmescConnRxOcmShelfThe connected OCM shelf (from MCMESC's Link Rx).ro
ShelfInput
.1.3.6.1.4.1.4253.1.18.6.1.47
mcmescConnRxOcmSlotThe connected OCM slot (from MCMESC's Link Rx).rw
SlotInput
.1.3.6.1.4.1.4253.1.18.6.1.48
mcmescConnRxOcmPortThe connected OCM port (from MCMESC's Link Rx). 3=OCM's CPE-Tx, 4=OCM's Rx. Only 3 is valid.rw
Enumeration
.1.3.6.1.4.1.4253.1.18.6.1.49
mcmescConnRxOcmShelfSlotAdd a connection from MCMESC Link-Rx to an OCM CPE-Tx by specifying the OCM's shelf and slot. The format is shlef,slot. If either MCMESC Link-Tx or specified OCM CPE-Rx has already had connection, an error will be returned. If the card specified by shelf,slot is not ocm type, an error will be returned. A get on this variable will always return 0,0rw
DisplayString
.1.3.6.1.4.1.4253.1.18.6.1.50
mcmescConnRxOcmDeleteDelete a connection from MCMESC Link-Rx to an OCM CPE-Tx. If MCMESC's Link-Rx has no connection with any OCM's CPE-Tx, an error will be returned. A get on this variable will always return an other.rw
Enumeration
.1.3.6.1.4.1.4253.1.18.6.1.51
mcmescSetStateInstruct the mcmesc card to do either a reset or loopback. A get on this will always return an other. If the card is in self-test, an error will be returned. If the card is already in any loopback, and try to turn on another loopback, an error will be returned.rw
Enumeration
.1.3.6.1.4.1.4253.1.18.6.1.52
mcmescLinkClrErrCountInstruct the mcmesc card to clear the bit-error count for link port. A get on this will always return an other.rw
Enumeration
.1.3.6.1.4.1.4253.1.18.6.1.53
mcmescPortNumberNumber of MCMESC rows in the following table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.18.7
mcmescPortTableThis table represents the information for each MCMESC module's port.
SEQUENCE OF McmescPortEntry
.1.3.6.1.4.1.4253.1.18.8
mcmescPortEntrySpecifies the index for each row in the table below
McmescPortEntry
.1.3.6.1.4.1.4253.1.18.8.1
mcmescPortCardLocationLocation of the MCMESC port. Valid values are: Local in the same chassis, or remote to this chassis.ro
CardLocation
.1.3.6.1.4.1.4253.1.18.8.1.1
mcmescPortCardShelfThe shelf the card is in. Valid values are: 1..2.ro
CardShelf
.1.3.6.1.4.1.4253.1.18.8.1.2
mcmescPortCardSlotThe slot within the shelf the Module is in. Valid values are: 1 to 17.ro
SlotInput
.1.3.6.1.4.1.4253.1.18.8.1.3
mcmescPortIndexCPE port's index. Valid values are: 1 to 12.ro
INTEGER
.1.3.6.1.4.1.4253.1.18.8.1.4
mcmescPortSfpSerialNumCPE port's SFP serial number.ro
SfpSerialString
.1.3.6.1.4.1.4253.1.18.8.1.5
mcmescPortConnectionStateCPE port's connection status.rw
Enumeration
.1.3.6.1.4.1.4253.1.18.8.1.6
mcmescPortClrErrCountInstruct the mcmesc card to clear the bit-error count for a CPE port. A get on this will always return an other.rw
Enumeration
.1.3.6.1.4.1.4253.1.18.8.1.7
systemConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.21
sysAddCardAdd card operation given type, shelf, slot, and optionally sub card type. The format is (type,shelf, slot[,optional]). If the fourth optional parameter is present, for OCMITU/OCMU, its value should be 1 to indicate OCMITU/OCMU with CSIM; for MCMESC, its value should be 0 or 1 to indicate MPM will not overide or will override the settings stored on MCMESC upon detecting it. Different types of card: OCMU: 2 //with or without csim module OCMI: 3 //with or without csim module OFCM: 4 OFCD: 5 FADM: 6 MCMT1: 8 W4CD: 10 W2CM/D: 13 OSAM: 20 W4CM: 21 RSM: 22 UPSM: 23 OCME: 24 OCM10G: 27 OSAM-LP: 29 OSAM-HP: 30 MCMESC: 33 WFADM: 34 MCME1: 35 MD100-1: 36 MD100-40: 37 TAP: 38 MD100-5 39 MD100-10 40 OCM10GLR 41 BD-4 42 BP-10 43 DMM 45 BP-5 46 OSC 48 OCM2 49 OCM10GF 50 OCM2-4G 51 OET 52 UOB 53 FC8G 54 MD100P 55 CWDM-BD4 56 For example, to add a FADM card in shelf 1, slot 8, this variable will be set to 6,1,8. To add an OCMI card with colorsim module in shelf 1, slot 7, this variable will be set to 3,1,7,1. To add an MCMESC card with override option in shelf 1, slot 7, this variable will be set to 33,1,7,1. A get on this will return 0,0,0,0rw
DisplayString
.1.3.6.1.4.1.4253.1.21.1
sysAlarmCtrlThe Master Control for Alarms. Will enable or disable all external and visual alarms of the system. The default state is enable.rw
Enumeration
.1.3.6.1.4.1.4253.1.21.2
sysAlarmCriticalTurns on or off all external critical audible and visual alarms.rw
Enumeration
.1.3.6.1.4.1.4253.1.21.3
sysAlarmMajorTurns on or off all external major and minor audible and visual alarms.rw
Enumeration
.1.3.6.1.4.1.4253.1.21.4
sysAlarmSerialEnables or disables the flow of TL1 alarms to the serial port.rw
Enumeration
.1.3.6.1.4.1.4253.1.21.5
sysAlarmAutoCutoffEnables or disables the AutoCutoff feature for dry-contact alarm closuresrw
Enumeration
.1.3.6.1.4.1.4253.1.21.6
sysAddRouteAdd route operation given local shelf, local slot, destination IP address and route Type. The format is (shelf, slot, route Type, destination IP). Different types of route types are: external Route: 1 (Route to an external non LuxN node) internal Route: 2 (Route to a LuxN node in the network) For example, to add an internal route to a LuxN node with IP address 192.162.6.65 from local shelf 1, slot 6 this variable would be set to 1,6,3,192.162.6.65 For adding an external route, shelf & slot needs to be zero. For e.g To add an external route to destination address 192.168.9.99, this variable needs to be set to 0,0,192.168.9.99 A get on this will return 0,0,0,0 NO LONGER SUPPORTED, user now needs to use sysImnAddRoute
DisplayString
.1.3.6.1.4.1.4253.1.21.7
sysDeleteRouteDelete route operation given local shelf, local slot & destination IP address . The format is (shelf, slot, destination IP). For example, to delete a route to a LuxN node with IP address 192.162.6.65 from local shelf 1, slot 6 this variable would be set to 1,6,192.162.6.65 A get on this will return 0,0,0 NO LONGER SUPPORTED, user now needs to use sysImnAddRoute
DisplayString
.1.3.6.1.4.1.4253.1.21.8
sysSwitchByPathIdInitiate UPSR switching by Path ID.rw
PathIdName
.1.3.6.1.4.1.4253.1.21.9
sysSwitchAllSwitch all CC cards that have backup.rw
Enumeration
.1.3.6.1.4.1.4253.1.21.10
sysAlarmMinorTurns on or off all external minor audible and visual alarms.rw
Enumeration
.1.3.6.1.4.1.4253.1.21.11
sysDelCfgDbAction to delete configuration database. MPM would reboot after the database is deleted. A get on it will return otherrw
Enumeration
.1.3.6.1.4.1.4253.1.21.12
sysImnAddRouteAdd route operation. It takes destination IP address, IP mask and the route metric. The format is (destination IP, IP mask, routeMetric). A get on this will return 0.0.0.0,0.0.0.0,0rw
DisplayString
.1.3.6.1.4.1.4253.1.21.13
sysImnDeleteRouteDelete route operation. It takes destination IP address and IP mask. The format is (destination IP, IP mask=). A get on this will return 0.0.0.0,0.0.0.0rw
DisplayString
.1.3.6.1.4.1.4253.1.21.14
sysExtAlarmInputTableThis table represents the input information for each external alarm indicator
SEQUENCE OF SysExtAlarmInputEntry
.1.3.6.1.4.1.4253.1.21.17
sysExtAlarmInputEntrySpecifies the index for each row in the table below
SysExtAlarmInputEntry
.1.3.6.1.4.1.4253.1.21.17.1
sysExtAlarmInputIdId of an external alarm indicator. Valid values are: 1 to 6ro
INTEGER
.1.3.6.1.4.1.4253.1.21.17.1.1
sysExtAlarmInputConfigurable value for an external alarm indicator. Default value is off. For the chassis with old sensor board, the value is na and is not settable.rw
Enumeration
.1.3.6.1.4.1.4253.1.21.17.1.2
sysExtAlarmInputNameUser configurable name for an external alarm input indicator. For the chassis with old sensor board, the value is na and is not settable.rw
AlarmType
.1.3.6.1.4.1.4253.1.21.17.1.3
sysAudioAlarmMode for audio alarm. Default is off. For non-carrier-class chassis, it is narw
Enumeration
.1.3.6.1.4.1.4253.1.21.18
sysAudioAlarmSeverityControls for audio alarm. When the control is set to minor, it will go off for all minor and up alarms. Default is major. For non-carrier-class chassis, it is na. These control only make sense for audio alarm in brief or continous moderw
Enumeration
.1.3.6.1.4.1.4253.1.21.19
sysRdbcopyForces a database copy to the standby MPM. Reading this element will always return 'other'. This element can only be set to 'copydb'. If the standby MPM is present then a database copy will be initiated, otherwise an error will be return.rw
Enumeration
.1.3.6.1.4.1.4253.1.21.20
sysRdbcopyStatusDisplays the percentage done for forced database copies. No value is returned if a forced database copy is not in progress.ro
INTEGER
.1.3.6.1.4.1.4253.1.21.21
sysSDMRequestsQueuedDisplays the number of requests in the SDM queue.ro
INTEGER
.1.3.6.1.4.1.4253.1.21.22
sysModuleupdateJobsWaitingDisplays the number of module updates jobs from the current request that must wait until one or more of the jobs progressing completes. This element will only be returned if one or more module update jobs are in progress.ro
INTEGER
.1.3.6.1.4.1.4253.1.21.23
sysModuleupdateJobsTableThis table defines the module update jobs in progress. Table entries will only be reutrned if one for more module update jobs are in progress.
SEQUENCE OF SysModuleupdateJobsEntry
.1.3.6.1.4.1.4253.1.21.24
sysModuleupdateJobsEntrySpecifies the index for each row in the table below
SysModuleupdateJobsEntry
.1.3.6.1.4.1.4253.1.21.24.1
sysModupdShelfShelf of the module being updated. For remote updates this will be the shelf of the local module through the update occurs.ro
INTEGER
.1.3.6.1.4.1.4253.1.21.24.1.1
sysModupdSlotSlot of the module being updated. For remote updates this will be the slot of the local module through the update occurs.ro
INTEGER
.1.3.6.1.4.1.4253.1.21.24.1.2
sysModupdLocationLocation (local or remote) of the module being updatedro
CardLocation
.1.3.6.1.4.1.4253.1.21.24.1.3
sysModupdRmtStationRemote station of the module being updatedro
INTEGER
.1.3.6.1.4.1.4253.1.21.24.1.4
sysModupdCardtypeType of module being updated.ro
CardType
.1.3.6.1.4.1.4253.1.21.24.1.5
sysModupdPercentDonePercentage of update completed.ro
INTEGER
.1.3.6.1.4.1.4253.1.21.24.1.6
sysSNMPKeepaliveEnableEnable or disable SNMP keep alive functionality.rw
Enumeration
.1.3.6.1.4.1.4253.1.21.25
sysSNMPKeepaliveIntervalSet the SNMP keep alive interval in minutes.rw
INTEGER
.1.3.6.1.4.1.4253.1.21.26
topology
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.22
topologyTableThis table represents the link topology between local and remote cards
SEQUENCE OF TopologyEntry
.1.3.6.1.4.1.4253.1.22.1
topologyEntrySpecifies the index for each row in the table below
TopologyEntry
.1.3.6.1.4.1.4253.1.22.1.1
topologyNearEndCardShelfShelf of the near end card.ro
CardShelf
.1.3.6.1.4.1.4253.1.22.1.1.1
topologyNearEndCardSlotSlot of the near end card. Input 0 will delete the topology link.rw
CardSlot
.1.3.6.1.4.1.4253.1.22.1.1.2
topologyNearEndCardPortIndexNear end optical link port.ro
PortIndex
.1.3.6.1.4.1.4253.1.22.1.1.3
topologyNearEndCardTypeCard type of the near end card.ro
CardType
.1.3.6.1.4.1.4253.1.22.1.1.4
topologyFarEndChassisIDChassis ID of the far end chassis. Part of manufacturing inforo
NodeName
.1.3.6.1.4.1.4253.1.22.1.1.5
topologyFarEndSystemNameName of the far end node/chassis. Not supported for remote TMM masters.ro
NodeName
.1.3.6.1.4.1.4253.1.22.1.1.6
topologyFarEndNodeIpAddressIpAddress of the far end chassis. Not supported for remote TMM masters.ro
IpAddress
.1.3.6.1.4.1.4253.1.22.1.1.7
topologyFarEndNodeCardShelfShelf of the far end modulero
CardShelf
.1.3.6.1.4.1.4253.1.22.1.1.8
topologyFarEndNodeCardSlotSlot of the far end modulero
CardSlot
.1.3.6.1.4.1.4253.1.22.1.1.9
topologyFarEndNodeCardPortIndexFar end optical link port.ro
PortIndex
.1.3.6.1.4.1.4253.1.22.1.1.10
topologyLinkStatusStatus of the link to indicate if active or downro
Enumeration
.1.3.6.1.4.1.4253.1.22.1.1.11
topologyFarEndNodeCardTypeCard type of the far end card.ro
CardType
.1.3.6.1.4.1.4253.1.22.1.1.12
topologyDiscoverAn action to rediscover the complete topology A get would alway return other(1).rw
Enumeration
.1.3.6.1.4.1.4253.1.22.2
routing
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.23
routingTableThis table represents dynamic and static routing information
SEQUENCE OF RoutingEntry
.1.3.6.1.4.1.4253.1.23.1
routingEntrySpecifies the index for each row in the table below
RoutingEntry
.1.3.6.1.4.1.4253.1.23.1.1
routeLocalCCShelfShelf of the local CC card.
CardShelf
.1.3.6.1.4.1.4253.1.23.1.1.1
routeLocalCCSlotSlot of the local CC card.
CardSlot
.1.3.6.1.4.1.4253.1.23.1.1.2
routeIpDestAddressDestination IP address. Not supported for remote TMM masters.
IpAddress
.1.3.6.1.4.1.4253.1.23.1.1.3
routeDestTypeDestination route type. External means destination is not part of LuxN network. Internal means destination is one of the LuxN node
Enumeration
.1.3.6.1.4.1.4253.1.23.1.1.4
routeModeIs the route added statically(manually) or dynamically(automatic)
Enumeration
.1.3.6.1.4.1.4253.1.23.1.1.5
imnDynamicRoutingTableThis table represents IMN based dynamic routing information
SEQUENCE OF ImnDynamicRoutingEntry
.1.3.6.1.4.1.4253.1.23.2
imnDynamicRoutingEntrySpecifies the index for each row in the table below
ImnDynamicRoutingEntry
.1.3.6.1.4.1.4253.1.23.2.1
imnDynamicRouteIpDestDestination IP address. Not supported for remote TMM masters.ro
IpAddress
.1.3.6.1.4.1.4253.1.23.2.1.1
imnDynamicRouteIpMaskDestination's IP mask address. Not supported for remote TMM masters.ro
IpAddress
.1.3.6.1.4.1.4253.1.23.2.1.2
imnDynamicRouteMetricCost associated with this route.ro
INTEGER
.1.3.6.1.4.1.4253.1.23.2.1.3
imnDynamicRouteNextHopNeighbour node of this route.ro
IpAddress
.1.3.6.1.4.1.4253.1.23.2.1.4
imnDynamicRouteSysNameDestination system name associated with route.ro
DisplayString
.1.3.6.1.4.1.4253.1.23.2.1.5
imnRouteUpdateTimerTime in seconds for the route table to get updated/propagated Default value is 30 seconds.rw
INTEGER
.1.3.6.1.4.1.4253.1.23.3
imnRouteKeepAliveTimerTime in seconds before neighbors enter unreachable state after communication is lost. This value has to be greater than or equal to imnRouteUpdateTimer Default value is 60 secondsrw
INTEGER
.1.3.6.1.4.1.4253.1.23.4
imnRouteUnReachableTimerTime in seconds before Neighbors in unreachable state are deleted from the route table. This value has to greater than or equal to imnRouteUpdateTimer Default value is 60 secondsrw
INTEGER
.1.3.6.1.4.1.4253.1.23.5
imnRouteModeEnable/Disable IMN functionality. Default is disabledrw
Enumeration
.1.3.6.1.4.1.4253.1.23.6
imnStaticRoutingTableThis table represents IMN based static routing information
SEQUENCE OF ImnStaticRoutingEntry
.1.3.6.1.4.1.4253.1.23.7
imnStaticRoutingEntrySpecifies the index for each row in the table below
ImnStaticRoutingEntry
.1.3.6.1.4.1.4253.1.23.7.1
imnStaticRouteIpDestDestination IP address. Not supported for remote TMM masters.ro
IpAddress
.1.3.6.1.4.1.4253.1.23.7.1.1
imnStaticRouteIpMaskDestination's IP mask address. Not supported for remote TMM masters.ro
IpAddress
.1.3.6.1.4.1.4253.1.23.7.1.2
imnStaticRouteMetricCost associated with this route.ro
INTEGER
.1.3.6.1.4.1.4253.1.23.7.1.3
imnRouteMaxMetricMaximum acceptable metric count before the routes gets dropped. Default value is 255. Ideally this value should be greater than imnStaticRouteMetricrw
INTEGER
.1.3.6.1.4.1.4253.1.23.8
ring
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.24
ringNumTotal number of ring configured in the list.ro
INTEGER
.1.3.6.1.4.1.4253.1.24.1
ringTableThis table represent the ring information
SEQUENCE OF RingEntry
.1.3.6.1.4.1.4253.1.24.2
ringEntrySpecifies the index for each row in the table below
RingEntry
.1.3.6.1.4.1.4253.1.24.2.1
ringIndexThe ringIndex and also the index of the ring table.
INTEGER
.1.3.6.1.4.1.4253.1.24.2.1.1
ringIDRingID Name for UPSR. Empty string will remove and deassociate the RingID with the PathIDs. You always has one dummy entry for adding another ring.rw
RingIdName
.1.3.6.1.4.1.4253.1.24.2.1.2
ringPathID1PathID 1 associate with this ring.rw
PathIdName
.1.3.6.1.4.1.4253.1.24.2.1.3
ringPathID2PathID 2 associate with this ring.rw
PathIdName
.1.3.6.1.4.1.4253.1.24.2.1.4
ringPath1RemoteIPIP Address of the neighbor node associated with path 1ro
IpAddress
.1.3.6.1.4.1.4253.1.24.2.1.5
ringPath1RemoteChassisIdChassis ID of the neighbor node associated with path 1ro
DisplayString
.1.3.6.1.4.1.4253.1.24.2.1.6
ringPath2RemoteIPIP Address of the neighbor node associated with path 2ro
IpAddress
.1.3.6.1.4.1.4253.1.24.2.1.7
ringPath2RemoteChassisIdChassis ID of the neighbor node associated with path 2ro
DisplayString
.1.3.6.1.4.1.4253.1.24.2.1.8
tap
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.25
tapNumberNumber of TAP rows in the following table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.25.1
tapTableThis table represents the information for each TAP module
SEQUENCE OF TapEntry
.1.3.6.1.4.1.4253.1.25.2
tapEntrySpecifies the index for each row in the table below
TapEntry
.1.3.6.1.4.1.4253.1.25.2.1
tapCardLocationLocation of the module. Valid values are: Local in the same chassis, or remote to this chassisro
CardLocation
.1.3.6.1.4.1.4253.1.25.2.1.1
tapCardShelfThe shelf the card is in.ro
CardShelf
.1.3.6.1.4.1.4253.1.25.2.1.2
tapCardSlotThe slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.25.2.1.3
tapModelNumModel number for module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.25.2.1.4
tapMfgDateDate and Time of manufacturing of the module
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.25.2.1.5
tapSerialNumSerial number of the module.ro
SerialString
.1.3.6.1.4.1.4253.1.25.2.1.6
tapModelTypeModel type of the modulero
CardType
.1.3.6.1.4.1.4253.1.25.2.1.7
tapNameUser configurable name of the modulerw
CardName
.1.3.6.1.4.1.4253.1.25.2.1.8
tapFWVersionIDThe current version string of the FW codero
VersionString
.1.3.6.1.4.1.4253.1.25.2.1.9
tapHWNameDisplay Hardware name of the module.ro
CardName
.1.3.6.1.4.1.4253.1.25.2.1.10
tapPathIDUpsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.25.2.1.11
tapAdminStateAdministrative control over that TAP card. Default value is enable. When disabled, no alarms/events gets generated.rw
Enumeration
.1.3.6.1.4.1.4253.1.25.2.1.12
tapCleiNumCLEI number for the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.25.2.1.13
tapNumPortsTotal port numbers on each TAP card.ro
INTEGER
.1.3.6.1.4.1.4253.1.25.2.1.14
voadm
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.26
voadmNumberNumber of rows in the voadm table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.26.1
voadmTableThis table represents the information for each VOADM card
SEQUENCE OF VoadmEntry
.1.3.6.1.4.1.4253.1.26.2
voadmEntrySpecifies the index for each row in the table below
VoadmEntry
.1.3.6.1.4.1.4253.1.26.2.1
voadmCardLocationLocation of the module. VOADM modules will always be seen as local modules.ro
CardLocation
.1.3.6.1.4.1.4253.1.26.2.1.1
voadmCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.26.2.1.2
voadmCardSlotThe slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.26.2.1.3
voadmSerialNumModule serial number.ro
SerialString
.1.3.6.1.4.1.4253.1.26.2.1.4
voadmModelNumModule model number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.2.1.5
voadmHwNameModule hardware name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.2.1.6
voadmHwVersionIDModule hardware version.ro
VersionString
.1.3.6.1.4.1.4253.1.26.2.1.7
voadmMfgDateDate and Time of manufacturing of the modulero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.2.1.8
voadmFwNameModule firmware name.ro
CardName
.1.3.6.1.4.1.4253.1.26.2.1.9
voadmFwVersionIDFirmware version.ro
VersionString
.1.3.6.1.4.1.4253.1.26.2.1.10
voadmFwDateFirmware release date and time.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.2.1.11
voadmAdminStateAdministrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.rw
Enumeration
.1.3.6.1.4.1.4253.1.26.2.1.12
voadmModelTypeModel type of the module.ro
CardType
.1.3.6.1.4.1.4253.1.26.2.1.13
voadmNameUser configurable name of the module.rw
CardName
.1.3.6.1.4.1.4253.1.26.2.1.14
voadmSetStateInstruct the module to do a warmboot. A get on this will always return 'other'.rw
RebootType
.1.3.6.1.4.1.4253.1.26.2.1.15
voadmPathIDPath ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.26.2.1.16
voadmCleiNumCLEI number of the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.2.1.17
voadmActiveChannelsNumber of active channels connected to the module. The allowed inpu range depends on the module type: MD100-5 1 to 5 MD100-10 1 to 10rw
INTEGER
.1.3.6.1.4.1.4253.1.26.2.1.18
voadmStartItuFirst ITU channel supported by the module.ro
INTEGER
.1.3.6.1.4.1.4253.1.26.2.1.19
voadmEndItuLast ITU channel supported by the module.ro
INTEGER
.1.3.6.1.4.1.4253.1.26.2.1.20
voadmNumPortsTotal port numbers on each VOADM card.ro
INTEGER
.1.3.6.1.4.1.4253.1.26.2.1.21
voadmPortTableThis table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
SEQUENCE OF VoadmPortEntry
.1.3.6.1.4.1.4253.1.26.3
voadmPortEntrySpecifies the index for each row in the table below
VoadmPortEntry
.1.3.6.1.4.1.4253.1.26.3.1
voadmPortCardLocationLocation of the module. VOADM modules will always be seen as local modules.ro
CardLocation
.1.3.6.1.4.1.4253.1.26.3.1.1
voadmPortCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.26.3.1.2
voadmPortCardSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.26.3.1.3
voadmPortTypePort type for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.26.3.1.4
voadmPortModePort mode. This value will not be stored in the database until the port set point is set.rw
Enumeration
.1.3.6.1.4.1.4253.1.26.3.1.5
voadmPortSetPointPort set point. Valid range depends on the port mode: Fixed Attentuation 0.0 to 20.0 (dB) Fixed Power -30.0 to 15.0 (dBm) Untils are omitted when setting.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.6
voadmPortMinChanInputPowerMinimum input power for each active channel. Valid range for Mux and Demux ports is -30.0 to 15.0 dBmrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.7
voadmPortMinChanOutputPowerMinimum output power for each active channel. Valid range depends on port: Mux -20.0 to 15.0 dBm Demux -30.0 to -8.0 dBm.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.8
voadmPortMaxChanOutputPowerMaximum output power for each active channel. Valid range depends on port: Mux -20.0 to 15.0 dBm Demux -30.0 to -8.0 dBm.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.9
voadmPortToleranceUpperBoundUpper bound for allowable power/attenuation error. Valid range is 0.2 to 10.0 dB.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.10
voadmPortToleranceLowerBoundLower bound for allowable power/attenuation error. Valid range is 0.2 to 10.0 dB.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.11
voadmPortTotalInputPowerPower reading from input detector. Valid range: -30 to 15 dBmro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.12
voadmPortPerChanInputPowerTotal input power divided by number of active channels. Valid range: -30 to 15 dBmro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.13
voadmPortTotalOutputPowerPower reading from output detector. Valid range: -30 to 15 dBmro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.14
voadmPortPerChanOutputPowerTotal output power divided by number of active channels. Valid range: -30 to 15 dBmro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.15
voadmPortMeasuredAttenDifference between total input power and total output power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.16
voadmPortAvgInsertLossAverage insertion loss for ports.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.17
voadmPortAvgExpressLossAverage express los for ports.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.26.3.1.18
zmsConfigSync
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.27
zmsConfigSyncExistsIndicates whether or not there exists records to be sent to the ZMS config synch manager for changes that have been made by CLI/HTTP to the data base.ro
Boolean
.1.3.6.1.4.1.4253.1.27.1
zmsConfigSyncOverflowIndicates whether or not the device had to discard update data base records due to resource constraints. If TRUE, traps will be sent to the ZMS Config Synch Manager indicating a download of the entire data base is required.ro
Boolean
.1.3.6.1.4.1.4253.1.27.2
zmsConfigSyncPriorityIndicates the highest priority configuration synchronization trap outstanding. This flag is set to none at boot time and whenever a file of synchronization changes has been sent to ZMS. If a parameter change has been made to either the same or lower prioirty, the device does not have to send a change notification to ZMS. Higher priority fields must immediately cause traps to be sent to ZMS.ro
Enumeration
.1.3.6.1.4.1.4253.1.27.3
zmsConfigSyncActionUsed by ZMS when it wants to create a list of config synch records. It must first write the filename expected and then set the action. The create list action allows the device to determine whether the complete database (synchoverflow occured) needs to be sent or only those records that have been modified. create full list specifies that ZMS would like to receive the complete database.rw
Enumeration
.1.3.6.1.4.1.4253.1.27.4
zmsConfigSyncFileNameFile Name to be used when creating the config synch records.rw
ZmsFileName
.1.3.6.1.4.1.4253.1.27.5
zmsConfigSyncStatusUsed by Config Sync Acgent when processing a request to create a list of config synch records.ro
Enumeration
.1.3.6.1.4.1.4253.1.27.6
zmsConfigSyncUserNameUser Name to be used when sending the config synch records. When read, the last user name is returned.rw
ZmsAdminString
.1.3.6.1.4.1.4253.1.27.7
zmsConfigSyncUserPasswordPassword to be used when sending the config synch records. For use in FTP authentication. When read, always returns the NULL stringrw
ZmsAdminString
.1.3.6.1.4.1.4253.1.27.8
zmsIpAddressThis is the ZMS IP address for which configuration synchronization messages and any other special handling is performed.rw
IpAddress
.1.3.6.1.4.1.4253.1.27.9
dmm
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.28
dmmNumberNumber of rows in the dmm table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.28.1
dmmTableThis table represents the information for each DMM card
SEQUENCE OF DmmEntry
.1.3.6.1.4.1.4253.1.28.2
dmmEntrySpecifies the index for each row in the table below
DmmEntry
.1.3.6.1.4.1.4253.1.28.2.1
dmmCardLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.28.2.1.1
dmmCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.28.2.1.2
dmmCardSlotThe slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.28.2.1.3
dmmSerialNumModule serial number.ro
SerialString
.1.3.6.1.4.1.4253.1.28.2.1.4
dmmModelNumModule model number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.28.2.1.5
dmmHwNameModule hardware name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.28.2.1.6
dmmHwVersionIDModule hardware version.ro
VersionString
.1.3.6.1.4.1.4253.1.28.2.1.7
dmmMfgDateDate and Time of manufacturing of the modulero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.28.2.1.8
dmmFwNameModule firmware name.ro
CardName
.1.3.6.1.4.1.4253.1.28.2.1.9
dmmFwVersionIDFirmware version.ro
VersionString
.1.3.6.1.4.1.4253.1.28.2.1.10
dmmFwDateFirmware release date and time.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.28.2.1.11
dmmAdminStateAdministrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.rw
Enumeration
.1.3.6.1.4.1.4253.1.28.2.1.12
dmmModelTypeModel type of the module.ro
CardType
.1.3.6.1.4.1.4253.1.28.2.1.13
dmmNameUser configurable name of the module.rw
CardName
.1.3.6.1.4.1.4253.1.28.2.1.14
dmmSetStateInstruct the module to do a warmboot. A get on this will always return 'other'.rw
Enumeration
.1.3.6.1.4.1.4253.1.28.2.1.15
dmmPathIDPath ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.28.2.1.16
dmmLinkNameLink name for fiber between the local and the remote card.rw
LinkName
.1.3.6.1.4.1.4253.1.28.2.1.17
dmmCleiNumCLEI number of the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.28.2.1.18
dmmNumPortsTotal port numbers on each DMM card.ro
INTEGER
.1.3.6.1.4.1.4253.1.28.2.1.19
dmmFpgaRevFPGA revision for the module.ro
INTEGER
.1.3.6.1.4.1.4253.1.28.2.1.20
dmmPortTableThis table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
SEQUENCE OF DmmPortEntry
.1.3.6.1.4.1.4253.1.28.3
dmmPortEntrySpecifies the index for each row in the table below
DmmPortEntry
.1.3.6.1.4.1.4253.1.28.3.1
dmmPortLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.28.3.1.1
dmmPortShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.28.3.1.2
dmmPortSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.28.3.1.3
dmmPortIndexPort for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.28.3.1.4
dmmPortLineRatePort line rate. Valid only for ports 1 and 2.rw
Enumeration
.1.3.6.1.4.1.4253.1.28.3.1.5
dmmPortAutoDisableFlag to enable/disable the CPE link when a fault is detected. Far end CPE disable is identical to normal CPE disable with the added feature that the local CPE Tx will be disabled if a loss of light condition is detected on the remote CPE Rx.rw
Enumeration
.1.3.6.1.4.1.4253.1.28.3.1.6
dmmPortModePort mode.ro
Enumeration
.1.3.6.1.4.1.4253.1.28.3.1.7
dmmPortItuPort ITU number. The ITU number is determined from the SFP wavelength.ro
INTEGER
.1.3.6.1.4.1.4253.1.28.3.1.8
dmmPortWavelengthWavelength from port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.28.3.1.9
dmmPortRxPowerReceive power reported by port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.28.3.1.10
dmmPortTxStateState of port SFP transmitter.ro
Enumeration
.1.3.6.1.4.1.4253.1.28.3.1.11
dmmPortTxReachOptical reach in meters reported by port SFP.ro
INTEGER
.1.3.6.1.4.1.4253.1.28.3.1.12
dmmPortSfpSerialNumberPort SFP serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.28.3.1.13
dmmPortSfpConnectorTypePort SFP connector type.ro
Enumeration
.1.3.6.1.4.1.4253.1.28.3.1.14
dmmConnTableThis table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
SEQUENCE OF DmmConnEntry
.1.3.6.1.4.1.4253.1.28.4
dmmConnEntrySpecifies the index for each row in the table below
DmmConnEntry
.1.3.6.1.4.1.4253.1.28.4.1
dmmConnCardLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.28.4.1.1
dmmConnCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.28.4.1.2
dmmConnCardSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.28.4.1.3
dmmConnCardPortTypePort for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.28.4.1.4
dmmConnCardTypeModule type connected to port.ro
CardType
.1.3.6.1.4.1.4253.1.28.4.1.5
dmmConnLocationThe chassis location of the card connected to this port.ro
CardLocation
.1.3.6.1.4.1.4253.1.28.4.1.6
dmmConnShelfThe shelf of the card connected to this portro
ShelfInput
.1.3.6.1.4.1.4253.1.28.4.1.7
dmmConnSlotThe slot of the card connected to this portro
SlotInput
.1.3.6.1.4.1.4253.1.28.4.1.8
dmmConnPortConn port for the DMM's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4.ro
INTEGER
.1.3.6.1.4.1.4253.1.28.4.1.9
ocm10gf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.29
ocm10gfNumberNumber of rows in the ocm10gf table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.29.1
ocm10gfTableThis table represents the information for each OCM10GF card
SEQUENCE OF Ocm10gfEntry
.1.3.6.1.4.1.4253.1.29.2
ocm10gfEntrySpecifies the index for each row in the table below
Ocm10gfEntry
.1.3.6.1.4.1.4253.1.29.2.1
ocm10gfCardLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.29.2.1.1
ocm10gfCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.29.2.1.2
ocm10gfCardSlotThe slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.29.2.1.3
ocm10gfSerialNumModule serial number.ro
SerialString
.1.3.6.1.4.1.4253.1.29.2.1.4
ocm10gfModelNumModule model number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.29.2.1.5
ocm10gfHwNameModule hardware name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.29.2.1.6
ocm10gfHwVersionIDModule hardware version.ro
VersionString
.1.3.6.1.4.1.4253.1.29.2.1.7
ocm10gfMfgDateDate and Time of manufacturing of the modulero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.29.2.1.8
ocm10gfFwNameModule firmware name.ro
CardName
.1.3.6.1.4.1.4253.1.29.2.1.9
ocm10gfFwVersionIDFirmware version.ro
VersionString
.1.3.6.1.4.1.4253.1.29.2.1.10
ocm10gfFwDateFirmware release date and time.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.29.2.1.11
ocm10gfModelTypeModel type of the module.ro
CardType
.1.3.6.1.4.1.4253.1.29.2.1.12
ocm10gfNameUser configurable name of the module.rw
CardName
.1.3.6.1.4.1.4253.1.29.2.1.13
ocm10gfLineRatePort line rate. Valid only for ports 1 and 2.rw
Enumeration
.1.3.6.1.4.1.4253.1.29.2.1.14
ocm10gfAutoDisableFlag to enable/disable the CPE link when a fault is detected. Far end CPE disable is identical to normal CPE disable with the added feature that the local CPE Tx will be disabled if a loss of light condition is detected on the remote CPE Rx.rw
Enumeration
.1.3.6.1.4.1.4253.1.29.2.1.15
ocm10gfLinkNameLink name for fiber between the local and the remote card.rw
LinkName
.1.3.6.1.4.1.4253.1.29.2.1.16
ocm10gfPathIDPath ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.29.2.1.17
ocm10gfAdminStateAdministrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.rw
Enumeration
.1.3.6.1.4.1.4253.1.29.2.1.18
ocm10gfSetStateInstruct the module to do a warmboot. A get on this will always return 'other'.rw
Enumeration
.1.3.6.1.4.1.4253.1.29.2.1.19
ocm10gfCleiNumCLEI number of the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.29.2.1.20
ocm10gfNumPortsTotal port numbers on each OCM10GF card.ro
INTEGER
.1.3.6.1.4.1.4253.1.29.2.1.21
ocm10gfFpgaRevFPGA revision for the module.ro
INTEGER
.1.3.6.1.4.1.4253.1.29.2.1.22
ocm10gfPortTableThis table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
SEQUENCE OF Ocm10gfPortEntry
.1.3.6.1.4.1.4253.1.29.3
ocm10gfPortEntrySpecifies the index for each row in the table below
Ocm10gfPortEntry
.1.3.6.1.4.1.4253.1.29.3.1
ocm10gfPortLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.29.3.1.1
ocm10gfPortShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.29.3.1.2
ocm10gfPortSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.29.3.1.3
ocm10gfPortIndexPort for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.29.3.1.4
ocm10gfPortModePort mode.ro
Enumeration
.1.3.6.1.4.1.4253.1.29.3.1.5
ocm10gfPortWavelengthWavelength from port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.29.3.1.6
ocm10gfPortRxPowerReceive power reported by port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.29.3.1.7
ocm10gfPortTxStateState of port SFP transmitter.ro
Enumeration
.1.3.6.1.4.1.4253.1.29.3.1.8
ocm10gfPortTxReachOptical reach in meters reported by port SFP.ro
INTEGER
.1.3.6.1.4.1.4253.1.29.3.1.9
ocm10gfPortXfpSerialNumberPort SFP serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.29.3.1.10
ocm10gfConnTableThis table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
SEQUENCE OF Ocm10gfConnEntry
.1.3.6.1.4.1.4253.1.29.4
ocm10gfConnEntrySpecifies the index for each row in the table below
Ocm10gfConnEntry
.1.3.6.1.4.1.4253.1.29.4.1
ocm10gfConnCardLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.29.4.1.1
ocm10gfConnCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.29.4.1.2
ocm10gfConnCardSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.29.4.1.3
ocm10gfConnCardPortTypePort for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.29.4.1.4
ocm10gfConnCardTypeModule type connected to port.ro
CardType
.1.3.6.1.4.1.4253.1.29.4.1.5
ocm10gfConnLocationThe chassis location of the card connected to this port.ro
CardLocation
.1.3.6.1.4.1.4253.1.29.4.1.6
ocm10gfConnShelfThe shelf of the card connected to this portro
ShelfInput
.1.3.6.1.4.1.4253.1.29.4.1.7
ocm10gfConnSlotThe slot of the card connected to this portro
SlotInput
.1.3.6.1.4.1.4253.1.29.4.1.8
ocm10gfConnPortConn port for the OCM10GF's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4.ro
INTEGER
.1.3.6.1.4.1.4253.1.29.4.1.9
ocm2
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.30
ocm2NumberNumber of rows in the ocm2 table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.30.1
ocm2TableThis table represents the information for each OCM2 card
SEQUENCE OF Ocm2Entry
.1.3.6.1.4.1.4253.1.30.2
ocm2EntrySpecifies the index for each row in the table below
Ocm2Entry
.1.3.6.1.4.1.4253.1.30.2.1
ocm2CardLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.30.2.1.1
ocm2CardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.30.2.1.2
ocm2CardSlotThe slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.30.2.1.3
ocm2SerialNumModule serial number.ro
SerialString
.1.3.6.1.4.1.4253.1.30.2.1.4
ocm2ModelNumModule model number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.30.2.1.5
ocm2HwNameModule hardware name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.30.2.1.6
ocm2HwVersionIDModule hardware version.ro
VersionString
.1.3.6.1.4.1.4253.1.30.2.1.7
ocm2MfgDateDate and Time of manufacturing of the modulero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.30.2.1.8
ocm2FwNameModule firmware name.ro
CardName
.1.3.6.1.4.1.4253.1.30.2.1.9
ocm2FwVersionIDFirmware version.ro
VersionString
.1.3.6.1.4.1.4253.1.30.2.1.10
ocm2FwDateFirmware release date and time.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.30.2.1.11
ocm2ModelTypeModel type of the module.ro
CardType
.1.3.6.1.4.1.4253.1.30.2.1.12
ocm2NameUser configurable name of the module.rw
CardName
.1.3.6.1.4.1.4253.1.30.2.1.13
ocm2Link1LineRateLink 1 line rate.rw
Enumeration
.1.3.6.1.4.1.4253.1.30.2.1.14
ocm2Link1AutoDisableFlag to enable/disable automatic CPE disable for Link 1.rw
Enumeration
.1.3.6.1.4.1.4253.1.30.2.1.15
ocm2Link1LinkNameLink 1 link name for fiber between the local and the remote card.rw
LinkName
.1.3.6.1.4.1.4253.1.30.2.1.16
ocm2Link1PathIDLink 1 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.30.2.1.17
ocm2Link2LineRateLink 2 line rate.rw
Enumeration
.1.3.6.1.4.1.4253.1.30.2.1.18
ocm2Link2AutoDisableFlag to enable/disable automatic CPE disable for Link 2.rw
Enumeration
.1.3.6.1.4.1.4253.1.30.2.1.19
ocm2Link2LinkNameLink 2 link name for fiber between the local and the remote card.rw
LinkName
.1.3.6.1.4.1.4253.1.30.2.1.20
ocm2Link2PathIDLink 2 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.30.2.1.21
ocm2AdminStateAdministrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.rw
Enumeration
.1.3.6.1.4.1.4253.1.30.2.1.22
ocm2SetStateInstruct the module to do a warmboot. A get on this will always return 'other'.rw
Enumeration
.1.3.6.1.4.1.4253.1.30.2.1.23
ocm2CleiNumCLEI number of the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.30.2.1.24
ocm2NumPortsTotal port numbers on each OCM2 card.ro
INTEGER
.1.3.6.1.4.1.4253.1.30.2.1.25
ocm2RegenModeSet or clear OCM2 regen mode.rw
Enumeration
.1.3.6.1.4.1.4253.1.30.2.1.26
ocm2FpgaRevFPGA revision for the module.ro
INTEGER
.1.3.6.1.4.1.4253.1.30.2.1.27
ocm2PortTableThis table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
SEQUENCE OF Ocm2PortEntry
.1.3.6.1.4.1.4253.1.30.3
ocm2PortEntrySpecifies the index for each row in the table below
Ocm2PortEntry
.1.3.6.1.4.1.4253.1.30.3.1
ocm2PortLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.30.3.1.1
ocm2PortShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.30.3.1.2
ocm2PortSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.30.3.1.3
ocm2PortIndexPort for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.30.3.1.4
ocm2PortModePort mode.ro
Enumeration
.1.3.6.1.4.1.4253.1.30.3.1.5
ocm2PortItuPort ITU number. The ITU number is determined from the SFP wavelength.ro
INTEGER
.1.3.6.1.4.1.4253.1.30.3.1.6
ocm2PortWavelengthWavelength from port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.30.3.1.7
ocm2PortRxPowerReceive power reported by port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.30.3.1.8
ocm2PortTxStateState of port SFP transmitter.ro
Enumeration
.1.3.6.1.4.1.4253.1.30.3.1.9
ocm2PortTxReachOptical reach in meters reported by port SFP.ro
INTEGER
.1.3.6.1.4.1.4253.1.30.3.1.10
ocm2PortSfpSerialNumberPort SFP serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.30.3.1.11
ocm2ConnTableThis table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
SEQUENCE OF Ocm2ConnEntry
.1.3.6.1.4.1.4253.1.30.4
ocm2ConnEntrySpecifies the index for each row in the table below
Ocm2ConnEntry
.1.3.6.1.4.1.4253.1.30.4.1
ocm2ConnCardLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.30.4.1.1
ocm2ConnCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.30.4.1.2
ocm2ConnCardSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.30.4.1.3
ocm2ConnCardPortTypePort for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.30.4.1.4
ocm2ConnCardTypeModule type connected to port.ro
CardType
.1.3.6.1.4.1.4253.1.30.4.1.5
ocm2ConnLocationThe chassis location of the card connected to this port.ro
CardLocation
.1.3.6.1.4.1.4253.1.30.4.1.6
ocm2ConnShelfThe shelf of the card connected to this portro
ShelfInput
.1.3.6.1.4.1.4253.1.30.4.1.7
ocm2ConnSlotThe slot of the card connected to this portro
SlotInput
.1.3.6.1.4.1.4253.1.30.4.1.8
ocm2ConnPortConn port for the OCM2's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4.ro
INTEGER
.1.3.6.1.4.1.4253.1.30.4.1.9
osc
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.31
oscNumberNumber of rows in the osc table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.31.1
oscTableThis table represents the information for each OSC card
SEQUENCE OF OscEntry
.1.3.6.1.4.1.4253.1.31.2
oscEntrySpecifies the index for each row in the table below
OscEntry
.1.3.6.1.4.1.4253.1.31.2.1
oscCardLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.31.2.1.1
oscCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.31.2.1.2
oscCardSlotThe slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.31.2.1.3
oscSerialNumModule serial number.ro
SerialString
.1.3.6.1.4.1.4253.1.31.2.1.4
oscModelNumModule model number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.31.2.1.5
oscHwNameModule hardware name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.31.2.1.6
oscHwVersionIDModule hardware version.ro
VersionString
.1.3.6.1.4.1.4253.1.31.2.1.7
oscMfgDateDate and Time of manufacturing of the modulero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.31.2.1.8
oscFwNameModule firmware name.ro
CardName
.1.3.6.1.4.1.4253.1.31.2.1.9
oscFwVersionIDFirmware version.ro
VersionString
.1.3.6.1.4.1.4253.1.31.2.1.10
oscFwDateFirmware release date and time.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.31.2.1.11
oscAdminStateAdministrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.rw
Enumeration
.1.3.6.1.4.1.4253.1.31.2.1.12
oscModelTypeModel type of the module.ro
CardType
.1.3.6.1.4.1.4253.1.31.2.1.13
oscNameUser configurable name of the module.rw
CardName
.1.3.6.1.4.1.4253.1.31.2.1.14
oscPathIDPath ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.31.2.1.15
oscSetStateInstruct the module to do a warmboot. A get on this will always return 'other'.rw
Enumeration
.1.3.6.1.4.1.4253.1.31.2.1.16
oscCleiNumCLEI number of the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.31.2.1.17
oscNumPortsTotal port numbers on each OSC card.ro
INTEGER
.1.3.6.1.4.1.4253.1.31.2.1.18
oscFpgaRevFPGA revision for the module.ro
INTEGER
.1.3.6.1.4.1.4253.1.31.2.1.19
oscPortTableThis table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
SEQUENCE OF OscPortEntry
.1.3.6.1.4.1.4253.1.31.3
oscPortEntrySpecifies the index for each row in the table below
OscPortEntry
.1.3.6.1.4.1.4253.1.31.3.1
oscPortLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.31.3.1.1
oscPortShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.31.3.1.2
oscPortSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.31.3.1.3
oscPortIndexPort for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.31.3.1.4
oscPortItuPort ITU number. The ITU number is determined from the SFP wavelength.ro
INTEGER
.1.3.6.1.4.1.4253.1.31.3.1.5
oscPortWavelengthWavelength from port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.31.3.1.6
oscPortRxPowerReceive power reported by port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.31.3.1.7
oscPortTxStateState of port SFP transmitter.ro
Enumeration
.1.3.6.1.4.1.4253.1.31.3.1.8
oscPortTxReachOptical reach in meters reported by port SFP.ro
INTEGER
.1.3.6.1.4.1.4253.1.31.3.1.9
oscPortSfpSerialNumberPort SFP serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.31.3.1.10
ocm4g
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.32
ocm4gNumberNumber of rows in the ocm4g table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.32.1
ocm4gTableThis table represents the information for each OCM4G card
SEQUENCE OF Ocm4gEntry
.1.3.6.1.4.1.4253.1.32.2
ocm4gEntrySpecifies the index for each row in the table below
Ocm4gEntry
.1.3.6.1.4.1.4253.1.32.2.1
ocm4gCardLocationLocation of the module.ro
Enumeration
.1.3.6.1.4.1.4253.1.32.2.1.1
ocm4gCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.32.2.1.2
ocm4gCardSlotThe slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.32.2.1.3
ocm4gSerialNumModule serial number.ro
SerialString
.1.3.6.1.4.1.4253.1.32.2.1.4
ocm4gModelNumModule model number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.32.2.1.5
ocm4gHwNameModule hardware name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.32.2.1.6
ocm4gHwVersionIDModule hardware version.ro
VersionString
.1.3.6.1.4.1.4253.1.32.2.1.7
ocm4gMfgDateDate and Time of manufacturing of the modulero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.32.2.1.8
ocm4gFwNameModule firmware name.ro
CardName
.1.3.6.1.4.1.4253.1.32.2.1.9
ocm4gFwVersionIDFirmware version.ro
VersionString
.1.3.6.1.4.1.4253.1.32.2.1.10
ocm4gFwDateFirmware release date and time.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.32.2.1.11
ocm4gModelTypeModel type of the module.ro
CardType
.1.3.6.1.4.1.4253.1.32.2.1.12
ocm4gNameUser configurable name of the module.rw
CardName
.1.3.6.1.4.1.4253.1.32.2.1.13
ocm4gLink1LineRateLink 1 line rate.rw
Enumeration
.1.3.6.1.4.1.4253.1.32.2.1.14
ocm4gLink1AutoDisableFlag to enable/disable automatic CPE disable for Link 1.rw
Enumeration
.1.3.6.1.4.1.4253.1.32.2.1.15
ocm4gLink1LinkNameLink 1 link name for fiber between the local and the remote card.rw
LinkName
.1.3.6.1.4.1.4253.1.32.2.1.16
ocm4gLink1PathIDLink 1 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.32.2.1.17
ocm4gLink2LineRateLink 2 line rate.rw
Enumeration
.1.3.6.1.4.1.4253.1.32.2.1.18
ocm4gLink2AutoDisableFlag to enable/disable automatic CPE disable for Link 2.rw
Enumeration
.1.3.6.1.4.1.4253.1.32.2.1.19
ocm4gLink2LinkNameLink 2 link name for fiber between the local and the remote card.rw
LinkName
.1.3.6.1.4.1.4253.1.32.2.1.20
ocm4gLink2PathIDLink 2 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.rw
PathIdName
.1.3.6.1.4.1.4253.1.32.2.1.21
ocm4gAdminStateAdministrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.rw
Enumeration
.1.3.6.1.4.1.4253.1.32.2.1.22
ocm4gSetStateInstruct the module to do a warmboot. A get on this will always return 'other'.rw
Enumeration
.1.3.6.1.4.1.4253.1.32.2.1.23
ocm4gCleiNumCLEI number of the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.32.2.1.24
ocm4gNumPortsTotal port numbers on each OCM4G card.ro
INTEGER
.1.3.6.1.4.1.4253.1.32.2.1.25
ocm4gFpgaRevFPGA revision for the module.ro
INTEGER
.1.3.6.1.4.1.4253.1.32.2.1.26
ocm4gPortTableThis table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
SEQUENCE OF Ocm4gPortEntry
.1.3.6.1.4.1.4253.1.32.3
ocm4gPortEntrySpecifies the index for each row in the table below
Ocm4gPortEntry
.1.3.6.1.4.1.4253.1.32.3.1
ocm4gPortLocationLocation of the module.ro
Enumeration
.1.3.6.1.4.1.4253.1.32.3.1.1
ocm4gPortShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.32.3.1.2
ocm4gPortSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.32.3.1.3
ocm4gPortIndexPort for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.32.3.1.4
ocm4gPortModePort mode.ro
Enumeration
.1.3.6.1.4.1.4253.1.32.3.1.5
ocm4gPortItuPort ITU number. The ITU number is determined from the SFP wavelength.ro
INTEGER
.1.3.6.1.4.1.4253.1.32.3.1.6
ocm4gPortWavelengthWavelength from port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.32.3.1.7
ocm4gPortRxPowerReceive power reported by port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.32.3.1.8
ocm4gPortTxStateState of port SFP transmitter.ro
Enumeration
.1.3.6.1.4.1.4253.1.32.3.1.9
ocm4gPortTxReachOptical reach in meters reported by port SFP.ro
INTEGER
.1.3.6.1.4.1.4253.1.32.3.1.10
ocm4gPortSfpSerialNumberPort SFP serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.32.3.1.11
ocm4gConnTableThis table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
SEQUENCE OF Ocm4gConnEntry
.1.3.6.1.4.1.4253.1.32.4
ocm4gConnEntrySpecifies the index for each row in the table below
Ocm4gConnEntry
.1.3.6.1.4.1.4253.1.32.4.1
ocm4gConnCardLocationLocation of the module.ro
Enumeration
.1.3.6.1.4.1.4253.1.32.4.1.1
ocm4gConnCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.32.4.1.2
ocm4gConnCardSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.32.4.1.3
ocm4gConnCardPortTypePort for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.32.4.1.4
ocm4gConnCardTypeModule type connected to port.ro
CardType
.1.3.6.1.4.1.4253.1.32.4.1.5
ocm4gConnLocationThe chassis location of the card connected to this port.ro
Enumeration
.1.3.6.1.4.1.4253.1.32.4.1.6
ocm4gConnShelfThe shelf of the card connected to this portro
ShelfInput
.1.3.6.1.4.1.4253.1.32.4.1.7
ocm4gConnSlotThe slot of the card connected to this portro
SlotInput
.1.3.6.1.4.1.4253.1.32.4.1.8
ocm4gConnPortConn port for the OCM4G's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4.ro
INTEGER
.1.3.6.1.4.1.4253.1.32.4.1.9
oet
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.33
oetNumberNumber of rows in the oet table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.33.1
oetTableThis table represents the information for each OET card
SEQUENCE OF OetEntry
.1.3.6.1.4.1.4253.1.33.2
oetEntrySpecifies the index for each row in the table below
OetEntry
.1.3.6.1.4.1.4253.1.33.2.1
oetCardLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.33.2.1.1
oetCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.33.2.1.2
oetCardSlotThe slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.33.2.1.3
oetSerialNumModule serial number.ro
SerialString
.1.3.6.1.4.1.4253.1.33.2.1.4
oetModelNumModule model number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.33.2.1.5
oetHwNameModule hardware name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.33.2.1.6
oetHwVersionIDModule hardware version.ro
VersionString
.1.3.6.1.4.1.4253.1.33.2.1.7
oetMfgDateDate and Time of manufacturing of the modulero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.33.2.1.8
oetFwNameModule firmware name.ro
CardName
.1.3.6.1.4.1.4253.1.33.2.1.9
oetFwVersionIDFirmware version.ro
VersionString
.1.3.6.1.4.1.4253.1.33.2.1.10
oetFwDateFirmware release date and time.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.33.2.1.11
oetModelTypeModel type of the module.ro
CardType
.1.3.6.1.4.1.4253.1.33.2.1.12
oetNameUser configurable name of the module.rw
CardName
.1.3.6.1.4.1.4253.1.33.2.1.13
oetCleiNumCLEI number of the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.33.2.1.14
oetFpgaRevMBFPGA revision for the module's mother board.ro
INTEGER
.1.3.6.1.4.1.4253.1.33.2.1.15
oetFpgaRevDBFPGA revision for the module's daughter board.ro
INTEGER
.1.3.6.1.4.1.4253.1.33.2.1.16
oetCpldRevCPLD revision for the module.ro
INTEGER
.1.3.6.1.4.1.4253.1.33.2.1.17
oetOpModeOperating Mode (1=Mux Mode, 2=Switch Mode).rw
Enumeration
.1.3.6.1.4.1.4253.1.33.2.1.18
oetProtModeMux Protection.rw
Enumeration
.1.3.6.1.4.1.4253.1.33.2.1.19
oetEAPSModeEthernet Automatic Protection Switching.rw
Enumeration
.1.3.6.1.4.1.4253.1.33.2.1.20
oetAdminStateAdministrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.rw
Enumeration
.1.3.6.1.4.1.4253.1.33.2.1.21
oetSetStateInstruct the module to do a warmboot. A get on this will always return 'other'.rw
Enumeration
.1.3.6.1.4.1.4253.1.33.2.1.22
oetConfigInProgressConfigured changes are pending, Apply Changes required to finish.ro
Enumeration
.1.3.6.1.4.1.4253.1.33.2.1.23
oetApplyChangesUpdate device with pending configuration changes. Read returns 'na'.rw
Enumeration
.1.3.6.1.4.1.4253.1.33.2.1.24
oetLinkTableThis table represents the information for each of the Link ports on the module.
SEQUENCE OF OetLinkEntry
.1.3.6.1.4.1.4253.1.33.3
oetLinkEntrySpecifies the index for each row in the table below
OetLinkEntry
.1.3.6.1.4.1.4253.1.33.3.1
oetLinkLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.33.3.1.1
oetLinkShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.33.3.1.2
oetLinkSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.33.3.1.3
oetLinkIndexLink for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.33.3.1.4
oetLinkEnableEnables or disables the link.rw
Enumeration
.1.3.6.1.4.1.4253.1.33.3.1.5
oetLinkProtocolProtocol.rw
Enumeration
.1.3.6.1.4.1.4253.1.33.3.1.6
oetLinkNameLink name for fiber between the local and the remote card.rw
CardName
.1.3.6.1.4.1.4253.1.33.3.1.7
oetLinkVlanIdsComma List of VLAN Ids - single and ranges.rw
DisplayString
.1.3.6.1.4.1.4253.1.33.3.1.8
oetLinkConfigInProgressConfigured changes are pending, Apply Changes required to finish.ro
Enumeration
.1.3.6.1.4.1.4253.1.33.3.1.9
oetLinkApplyChangesUpdate device with pending configuration changes. Read returns 'na'.rw
Enumeration
.1.3.6.1.4.1.4253.1.33.3.1.10
oetLinkModeLink mode.ro
Enumeration
.1.3.6.1.4.1.4253.1.33.3.1.11
oetLinkItuLink ITU number. The ITU number is determined from the XFP wavelength.ro
INTEGER
.1.3.6.1.4.1.4253.1.33.3.1.12
oetLinkWavelengthWavelength from Link XFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.33.3.1.13
oetLinkRxPowerReceive power reported by Link XFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.33.3.1.14
oetLinkTxStateState of Link XFP transmitter.ro
Enumeration
.1.3.6.1.4.1.4253.1.33.3.1.15
oetLinkTxReachOptical reach in meters reported by Link XFP.ro
INTEGER
.1.3.6.1.4.1.4253.1.33.3.1.16
oetLinkXfpSerialNumberLink XFP serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.33.3.1.17
oetPortTableThis table represents the information for each of the CPE ports on the module.
SEQUENCE OF OetPortEntry
.1.3.6.1.4.1.4253.1.33.4
oetPortEntrySpecifies the index for each row in the table below
OetPortEntry
.1.3.6.1.4.1.4253.1.33.4.1
oetPortLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.33.4.1.1
oetPortShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.33.4.1.2
oetPortSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.33.4.1.3
oetPortIndexPort for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.33.4.1.4
oetPortEnableEnables or disables the port.rw
Enumeration
.1.3.6.1.4.1.4253.1.33.4.1.5
oetPortALSDAuto Laser Shutoffrw
Enumeration
.1.3.6.1.4.1.4253.1.33.4.1.6
oetPortFlowControlEnable or disable the port's flow control.rw
Enumeration
.1.3.6.1.4.1.4253.1.33.4.1.7
oetPortVlanIdNetwork ID must be between 1 to 200.rw
INTEGER
.1.3.6.1.4.1.4253.1.33.4.1.8
oetPortNamePort name.rw
CardName
.1.3.6.1.4.1.4253.1.33.4.1.9
oetPortConfigInProgressConfigured changes are pending, Apply Changes required to finish.ro
Enumeration
.1.3.6.1.4.1.4253.1.33.4.1.10
oetPortApplyChangesUpdate device with pending configuration changes. Read returns 'na'.rw
Enumeration
.1.3.6.1.4.1.4253.1.33.4.1.11
oetPortModePort mode.ro
Enumeration
.1.3.6.1.4.1.4253.1.33.4.1.12
oetPortItuPort ITU number. The ITU number is determined from the SFP wavelength.ro
INTEGER
.1.3.6.1.4.1.4253.1.33.4.1.13
oetPortWavelengthWavelength from Port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.33.4.1.14
oetPortRxPowerReceive power reported by Port SFP.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.33.4.1.15
oetPortTxStateState of Port SFP transmitter.ro
Enumeration
.1.3.6.1.4.1.4253.1.33.4.1.16
oetPortTxReachOptical reach in meters reported by Port SFP.ro
INTEGER
.1.3.6.1.4.1.4253.1.33.4.1.17
oetPortSfpSerialNumberPort SFP serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.33.4.1.18
uob
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.34
uobNumberNumber of rows in the uob table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.34.1
uobTableThis table represents the information for each UOB card
SEQUENCE OF UobEntry
.1.3.6.1.4.1.4253.1.34.2
uobEntrySpecifies the index for each row in the table below
UobEntry
.1.3.6.1.4.1.4253.1.34.2.1
uobCardLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.34.2.1.1
uobCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.34.2.1.2
uobCardSlotThe slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.34.2.1.3
uobSerialNumModule serial number.ro
SerialString
.1.3.6.1.4.1.4253.1.34.2.1.4
uobModelNumModule model number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.34.2.1.5
uobHwNameModule hardware name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.34.2.1.6
uobHwVersionIDModule hardware version.ro
VersionString
.1.3.6.1.4.1.4253.1.34.2.1.7
uobMfgDateDate and Time of manufacturing of the modulero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.34.2.1.8
uobFwNameModule firmware name.ro
CardName
.1.3.6.1.4.1.4253.1.34.2.1.9
uobFwVersionIDFirmware version.ro
VersionString
.1.3.6.1.4.1.4253.1.34.2.1.10
uobFwDateFirmware release date and time.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.34.2.1.11
uobModelTypeModel type of the module.ro
CardType
.1.3.6.1.4.1.4253.1.34.2.1.12
uobCfgNameUser configurable name of the module.rw
CardName
.1.3.6.1.4.1.4253.1.34.2.1.13
uobModuleNamename of the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.34.2.1.14
uobAdminStateAdministrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.rw
Enumeration
.1.3.6.1.4.1.4253.1.34.2.1.15
uobSetStateInstruct the module to do a warmboot. A get on this will always return 'other'.rw
Enumeration
.1.3.6.1.4.1.4253.1.34.2.1.16
uobCleiNumCLEI number of the module.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.34.2.1.17
uobFpgaRevFPGA revision for the module.ro
INTEGER
.1.3.6.1.4.1.4253.1.34.2.1.18
uobOperationModeInvalid, Constain Power, Constant Gain, Disabled. Constain Power(1) is not valid on Fixed modules.rw
Enumeration
.1.3.6.1.4.1.4253.1.34.2.1.19
uobOutPoweruobModuleName - Configured Power in dBm T17VO - range: -13.0 to 17.5 T17VR - range: -13.0 to 17.5 T20FR - range: -7.0 to 20.10 T15FR - range: -7.0 to 15.10rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.34.2.1.20
uobGainuobModuleName - Configured Gain in dB T17VO - range: 10.0 to 20.0 T17VR - range: 10.0 to 20.0 T20FR - range: 16.0 to 28.0 default:22 T15FR - range: 16.0 to 28.0 default:22rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.34.2.1.21
uobGainTiltuobModuleName - Configured Gain Tilt in dB T17VO - range: -2.0 to 2.0 T17VR - range: -2.0 to 2.0rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.34.2.1.22
uobLosModeNo effect, Disabled in all modes, Disabled in Power Mode onlyrw
Enumeration
.1.3.6.1.4.1.4253.1.34.2.1.23
uobLosThresholduobModuleName - Configured Los Threshold in dBm T17VO - range: -100.0 to 45.0 default: -31 T17VR - range: -100.0 to 45.0 default: -31 T20FR - range: -40.0 to -5.0 default: -35 T15FR - range: -40.0 to -5.0 default: -35rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.34.2.1.24
uobRflThresholduobModuleName - Configured Rfl Threshold in dB T17VO - range: 0.0 to 50.0 T17VR - range: -23.0 to -14.0 T20FR - range: -23.0 to -14.0 T15FR - range: -23.0 to -14.0rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.34.2.1.25
fc8g
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.1.35
fc8gNumberNumber of rows in the fc8g table. This number is automatically updated whenever a new row is added to the table below.ro
INTEGER
.1.3.6.1.4.1.4253.1.35.1
fc8gTableThis table represents the information for each FC8G card
SEQUENCE OF Fc8gEntry
.1.3.6.1.4.1.4253.1.35.2
fc8gEntrySpecifies the index for each row in the table below
Fc8gEntry
.1.3.6.1.4.1.4253.1.35.2.1
fc8gCardLocationLocation of the module.ro
Enumeration
.1.3.6.1.4.1.4253.1.35.2.1.1
fc8gCardShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.35.2.1.2
fc8gCardSlotThe slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.rw
SlotInput
.1.3.6.1.4.1.4253.1.35.2.1.3
fc8gSerialNumModule serial number.ro
SerialString
.1.3.6.1.4.1.4253.1.35.2.1.4
fc8gModelNumModule model number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.35.2.1.5
fc8gHwNameModule hardware name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.35.2.1.6
fc8gHwVersionIDModule hardware version.ro
VersionString
.1.3.6.1.4.1.4253.1.35.2.1.7
fc8gMfgDateDate and Time of manufacturing of the modulero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.35.2.1.8
fc8gFwNameModule firmware name.ro
CardName
.1.3.6.1.4.1.4253.1.35.2.1.9
fc8gFwVersionIDFirmware version.ro
VersionString
.1.3.6.1.4.1.4253.1.35.2.1.10
fc8gFwDateFirmware release date and time.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.35.2.1.11
fc8gModelTypeModel type of the module.ro
CardType
.1.3.6.1.4.1.4253.1.35.2.1.12
fc8gNameUser configurable name of the module.rw
CardName
.1.3.6.1.4.1.4253.1.35.2.1.13
fc8gLink1DataRateLink 1 Data rate.rw
Enumeration
.1.3.6.1.4.1.4253.1.35.2.1.14
fc8gCpe1AutoDisableFlag to enable/disable automatic CPE disable for Link 1.rw
Enumeration
.1.3.6.1.4.1.4253.1.35.2.1.15
fc8gCpe1LaserEnabledFlag to enable/disable the CPE laser for Link 1.rw
Enumeration
.1.3.6.1.4.1.4253.1.35.2.1.16
fc8gLink1LaserEnabledFlag to enable/disable the LINK laser for Link 1.rw
Enumeration
.1.3.6.1.4.1.4253.1.35.2.1.17
fc8gLink2DataRateLink 2 Data rate.rw
Enumeration
.1.3.6.1.4.1.4253.1.35.2.1.18
fc8gCpe2AutoDisableFlag to enable/disable automatic CPE disable for Link 2.rw
Enumeration
.1.3.6.1.4.1.4253.1.35.2.1.19
fc8gCpe2LaserEnabledFlag to enable/disable the CPE laser for Link 2.rw
Enumeration
.1.3.6.1.4.1.4253.1.35.2.1.20
fc8gLink2LaserEnabledFlag to enable/disable the LINK laser for Link 2.rw
Enumeration
.1.3.6.1.4.1.4253.1.35.2.1.21
fc8gAdminStateAdministrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.rw
Enumeration
.1.3.6.1.4.1.4253.1.35.2.1.22
fc8gSetStateInstruct the module to do a warmboot or loopback. Successive loopbacks can be issued. A get on this will always return 'other'.rw
Enumeration
.1.3.6.1.4.1.4253.1.35.2.1.23
fc8gPortTableThis table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
SEQUENCE OF Fc8gPortEntry
.1.3.6.1.4.1.4253.1.35.3
fc8gPortEntrySpecifies the index for each row in the table below
Fc8gPortEntry
.1.3.6.1.4.1.4253.1.35.3.1
fc8gPortLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.1.35.3.1.1
fc8gPortShelfThe shelf where the module resides.ro
CardShelf
.1.3.6.1.4.1.4253.1.35.3.1.2
fc8gPortSlotThe slot within the shelf where the module resides.ro
SlotInput
.1.3.6.1.4.1.4253.1.35.3.1.3
fc8gPortIndexPort for which the below values apply.ro
Enumeration
.1.3.6.1.4.1.4253.1.35.3.1.4
fc8gPortNamePort name.ro
CardName
.1.3.6.1.4.1.4253.1.35.3.1.5
fc8gPortModePort mode.ro
Enumeration
.1.3.6.1.4.1.4253.1.35.3.1.6
fc8gPortWavelengthPort wavelength.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.35.3.1.7
fc8gPortRxPowerReported port receive power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.35.3.1.8
fc8gPortTxStateState of port transmitter.ro
Enumeration
.1.3.6.1.4.1.4253.1.35.3.1.9
fc8gPortTxReachPort optical reach in meters.ro
INTEGER
.1.3.6.1.4.1.4253.1.35.3.1.10
fc8gPortSfpXfpSerialNumberPort SFP/XFP serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.1.35.3.1.11
performance
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2
current1
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1
systemPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.1
sysStatusThe global status of the system as computed based on the traps (events) that are generated. Choices are: Critical, Major, Minor or Normal.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.1.1
sysClearStatusReset the system state to Normal. The value of reset means set the state to Normal. A get on this will always return other. Note: This element is now made not-accessible as sysStatus is now a read-only element
ResetType
.1.3.6.1.4.1.4253.2.1.1.2
sysClearCountersReset all performance counters in this 15 minutes time interval to zero. The value of reset means to reset the counters to zero. A get on this will always return other.rw
ResetType
.1.3.6.1.4.1.4253.2.1.1.3
sysLastBootTimeThe date and time of the last system boot. This time represents the boot time of a CP card. It is also anonymous with the power-up cycle of the chassis.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.1.4
sysAvailTimeThe number of seconds in this time slot (15 minutes) that the system has been up and running. This will generally be the same as 15 minutes in seconds (900), but, if the system has been reboot in the last 15 minutes interval, then it represents the number of seconds the system has been up. The criteria for the system available time is having at least one CP running with atmost non-service affecting minor alarm system statusro
Counter
.1.3.6.1.4.1.4253.2.1.1.5
sysErrFreeSecsThe number of seconds in this time slot (15 minutes) that the device has not experienced any alarms. This counter is across all cards in the chassis. The system must be in Normal status for this counter to be incremented.ro
Counter
.1.3.6.1.4.1.4253.2.1.1.6
sysExhaustTemperatureTemperature of the Chassis. Units of dgree centigrade.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.1.7
downloadPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.2
dlStatusThe global status of the download task. The download task (download to the device) is either ftp-inprogress, module update inprogrss or currently idle. Since only one download at the time is handled by the system, this flag is set to inprogress as soon as any download starts. It is reset back to idle when the download is completed. This flag is set to idle on system startup. This flag can be remotely set to idle if a previous FTP download was interrupted.rw
DownloadStatus
.1.3.6.1.4.1.4253.2.1.2.1
dlOkDownloadsThe number of successful downloads in this time interval (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.2.2
dlBadDownloadsThe number of failed downloads in this time interval (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.2.3
dlLongestTimeLongest time for any download, in seconds, in this time interval (15 minutes).ro
Gauge
.1.3.6.1.4.1.4253.2.1.2.4
dlLongestSizeLongest download size for any download, in bytes, in this time interval (15 minutes).ro
Gauge
.1.3.6.1.4.1.4253.2.1.2.5
cpPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.3
cpNumEventsTotal number of events received by the active CP in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.3.1
cpTrapsSentTotal number of traps sent by the active CP in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.3.2
cpSNMPCmdsRcvdTotal number of SNMP commands received by the active CP in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.3.3
cpCounterFlagTurns software counters On or Off.rw
FlagType
.1.3.6.1.4.1.4253.2.1.3.4
cpCntrTableThis table represents the information for each entry of the software counters. It is only applicable to the active MPM card.
SEQUENCE OF CpCntrEntry
.1.3.6.1.4.1.4253.2.1.3.5
cpCntrEntrySpecifies the index for each row in the table below
CpCntrEntry
.1.3.6.1.4.1.4253.2.1.3.5.1
cpCntrShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the value of the current active CP card.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.3.5.1.1
cpCntrSlotThe slot within the shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the value of the current active CP card.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.3.5.1.2
cpCntrTypeThe type of the software counter data in this row. The data is collected for the SPI data channels.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.3.5.1.3
cpTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.3.5.1.4
cpTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.3.5.1.5
cpBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.3.5.1.6
cpTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.3.5.1.7
cpBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.3.5.1.8
cpBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.3.5.1.9
cpMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.3.5.1.10
cpBufAllocFailNumber of buffer allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.3.5.1.11
cpEcbAllocFailNumber of Event Control Block allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.3.5.1.12
cpClearCntrsIf the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.3.5.1.13
cpPerfTableThis table represents the information for performance data collected for each communication processor
SEQUENCE OF CpPerfEntry
.1.3.6.1.4.1.4253.2.1.3.6
cpPerfEntrySpecifies the index for each row in the table below
CpPerfEntry
.1.3.6.1.4.1.4253.2.1.3.6.1
cpPerfShelfThe shelf the card is in. Valid values are: 1 to 2ro
CardShelf
.1.3.6.1.4.1.4253.2.1.3.6.1.1
cpPerfSlotThe slot within the shelf the card is in. Valid values are: 1 to 3ro
CardSlot
.1.3.6.1.4.1.4253.2.1.3.6.1.2
cpPerfModeThe valid types are: active CP or standby CPro
RedundancyMode
.1.3.6.1.4.1.4253.2.1.3.6.1.3
cpPerfStateThe status of the communication card. The status' are: online, offline, empty, loopback or diagnostics.ro
CardState
.1.3.6.1.4.1.4253.2.1.3.6.1.4
cpPerfStatusThe status of the communication processor. This status represents the state of the communication processor and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.3.6.1.5
cpLastBootTimeThe date and time of the last boot for this CP.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.3.6.1.6
cpAvailTimeThe number of seconds in this time slot (15 minutes) that this CP has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.3.6.1.7
cpErrFreeSecsThe number of seconds in this time slot (15 minutes) that this CP has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.3.6.1.8
ccPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.4
ccNumEventsTotal number of events received for all CC's in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.4.1
ccCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF CcCntrEntry
.1.3.6.1.4.1.4253.2.1.4.2
ccCntrEntrySpecifies the index for each row in the table below
CcCntrEntry
.1.3.6.1.4.1.4253.2.1.4.2.1
ccCntrLocationThe location of the CC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known CC cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.4.2.1.1
ccCntrShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) CC cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.4.2.1.2
ccCntrSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) CC cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.4.2.1.3
ccCntrTypeThe type of the software counter data in this row. The data is collected for the SPI data channels.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.4.2.1.4
ccCounterFlagTurns software counters, both On or both Off for this CC. When set to Off, both counters statistic information will be cleared.rw
FlagType
.1.3.6.1.4.1.4253.2.1.4.2.1.5
ccTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.4.2.1.6
ccTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.4.2.1.7
ccBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.4.2.1.8
ccTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.4.2.1.9
ccBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.4.2.1.10
ccBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.4.2.1.11
ccMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.4.2.1.12
ccBufAllocFailNumber of buffer allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.4.2.1.13
ccEcbAllocFailNumber of Event Control Block allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.4.2.1.14
ccClearCntrsIf the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.4.2.1.15
ccPerfTableThis table represents the information for performance data collected for each channel card
SEQUENCE OF CcPerfEntry
.1.3.6.1.4.1.4253.2.1.4.3
ccPerfEntrySpecifies the index for each row in the table below
CcPerfEntry
.1.3.6.1.4.1.4253.2.1.4.3.1
ccPerfLocationThe location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.4.3.1.1
ccPerfShelfThe shelf the card is in. Valid values are: 1 to 10ro
CardShelf
.1.3.6.1.4.1.4253.2.1.4.3.1.2
ccPerfSlotThe slot within the shelf the card is in. Valid values are: 4 to 42ro
CardSlot
.1.3.6.1.4.1.4253.2.1.4.3.1.3
ccPerfStateThe state of the channel card. The states' are: online, offline, empty, loopback or diagnostics.ro
CardState
.1.3.6.1.4.1.4253.2.1.4.3.1.4
ccPerfStatusThe status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.4.3.1.5
ccLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.4.3.1.6
ccAvailTimeThe number of seconds in this time slot (15 minutes) that this CC has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.4.3.1.7
ccErrFreeSecsThe number of seconds in this time slot (15 minutes) that this CC has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.4.3.1.8
ccBiasCurrentBias current for the optical laser.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.4.3.1.9
ccModulationThe frequency modulation for the optical laser.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.4.3.1.10
ccApcThe APC value.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.4.3.1.11
ccIwmModulationThe frequency modulation for the IWM channel.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.4.3.1.12
ccLaserOnOffThe laser On/Off flag.ro
FlagType
.1.3.6.1.4.1.4253.2.1.4.3.1.13
ccTemperatureThe current temperature, or the operating temperature of the optical device.ro
Gauge
.1.3.6.1.4.1.4253.2.1.4.3.1.14
ccIntensityThe intensity of the optical light.ro
Gauge
.1.3.6.1.4.1.4253.2.1.4.3.1.15
ccSignalStrengthThe current signal strength for the optical path.ro
Gauge
.1.3.6.1.4.1.4253.2.1.4.3.1.16
ccLossOfLightIf set to true, no laser light is present. If set to false, no loss of light has occurred.ro
Boolean
.1.3.6.1.4.1.4253.2.1.4.3.1.17
ccSignalDetectIf set to true, signal is detected. If set to false, no signal is present. Replaced with ccCpeRxSigDetect
Boolean
.1.3.6.1.4.1.4253.2.1.4.3.1.18
ccRefClockThe value of the reference clock in decimal notation. For a given value, like 1660, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor.
Enumeration
.1.3.6.1.4.1.4253.2.1.4.3.1.19
ccClockDivThe clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale.
Enumeration
.1.3.6.1.4.1.4253.2.1.4.3.1.20
ccLinkTxPwrStatusThis indicates whether the link transmit power is within the normal range of operation.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.4.3.1.21
ccLinkRxSigStrStatusThis indicates whether the link's receive signal is within the normal range of operation.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.4.3.1.22
ccCpeRxSigDetectThis indicates whether there is presence of CPE receive signalro
Enumeration
.1.3.6.1.4.1.4253.2.1.4.3.1.23
ccLinkIWMStatusThis indicates the current status of IWM. This value is only applicable to remote OCMsro
Enumeration
.1.3.6.1.4.1.4253.2.1.4.3.1.24
ccLinkSummaryStatusThis is the result of a logical and operation of all the individual link status. If any of the attributes is N/A, except for the local local IWM status, this value is N/Aro
Enumeration
.1.3.6.1.4.1.4253.2.1.4.3.1.25
ccProtectionModeUPSR Protection Mode: active, standby and n/a.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.4.3.1.26
ccLinkRxSigStrLink's received signal strength in dBm.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.4.3.1.27
muxPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.5
muxNumEventsTotal number of all traps (events) generated by all MUX's in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.5.1
muxPerfTableThis table represents the information for performance data collected for each mux/demux card
SEQUENCE OF MuxPerfEntry
.1.3.6.1.4.1.4253.2.1.5.2
muxPerfEntrySpecifies the index for each row in the table below
MuxPerfEntry
.1.3.6.1.4.1.4253.2.1.5.2.1
muxPerfLocationThe location of the card. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.5.2.1.1
muxPerfShelfThe shelf the card is in. Valid values are: 1 to 10ro
CardShelf
.1.3.6.1.4.1.4253.2.1.5.2.1.2
muxPerfSlotThe slot within the shelf the card is in. Valid values are: 1 to 42ro
CardSlot
.1.3.6.1.4.1.4253.2.1.5.2.1.3
muxTypeThe type of the mux. The choices are: mux or demux.ro
CardType
.1.3.6.1.4.1.4253.2.1.5.2.1.4
muxPerfStateThe state of the mux card. The states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.5.2.1.5
muxPerfStatusThe status of the mux card. This status represents the status of the mux card and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.5.2.1.6
muxLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.5.2.1.7
muxAvailTimeThe number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.5.2.1.8
muxErrFreeSecsThe number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.5.2.1.9
psPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.6
psNumEventsTotal number of all traps (events) generated by all Power Supplies in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.6.1
psVoltageLevel3pt4VoltVoltage Level of the 3.4 V power supply.ro
DisplayString
.1.3.6.1.4.1.4253.2.1.6.2
psVoltageLevel5pt1VoltVoltage Level of the 5.1 V power supply.ro
DisplayString
.1.3.6.1.4.1.4253.2.1.6.3
psVoltageLevel12VoltVoltage Level of the 12 V power supply.ro
DisplayString
.1.3.6.1.4.1.4253.2.1.6.4
psPerfTableThis table represents the information for performance data collected for each power supply card
SEQUENCE OF PsPerfEntry
.1.3.6.1.4.1.4253.2.1.6.5
psPerfEntrySpecifies the index for each row in the table below
PsPerfEntry
.1.3.6.1.4.1.4253.2.1.6.5.1
psPerfIDThe module ID where the PS is plugged in.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.6.5.1.1
psPerfTypeThe type of the power supply.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.6.5.1.2
psPerfStateThe state of the power supply module.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.6.5.1.3
psPerfStatusThe status of the power supply module. This status represents the status of the ps module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.6.5.1.4
psVoltageLevelFeedAVoltage Level of the -48 VDC input from Feed A.ro
DisplayString
.1.3.6.1.4.1.4253.2.1.6.6
psVoltageLevelFeedBVoltage Level of the -48 VDC input from Feed B.ro
DisplayString
.1.3.6.1.4.1.4253.2.1.6.7
psBreakerConditionFeedAState of Feed A breaker.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.6.8
psPerfStatusFeedAState of Feed A breaker. Failed if it goes into shutdown condition Unknown if the corresponding breaker is openro
Enumeration
.1.3.6.1.4.1.4253.2.1.6.9
psBreakerConditionFeedBState of Feed B breaker.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.6.10
psPerfStatusFeedBState of Feed B. Failed if it goes into shutdown condition Unknown if the corresponding breaker is openro
Enumeration
.1.3.6.1.4.1.4253.2.1.6.11
fadmPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.7
fadmNumEventsTotal number of all traps (events) generated by all MUX's in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.7.1
fadmPerfTableThis table represents the information for performance data collected for each fadm card
SEQUENCE OF FadmPerfEntry
.1.3.6.1.4.1.4253.2.1.7.2
fadmPerfEntrySpecifies the index for each row in the table below
FadmPerfEntry
.1.3.6.1.4.1.4253.2.1.7.2.1
fadmPerfLocationThe location of the card. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.7.2.1.1
fadmPerfShelfThe shelf the card is in. Valid values are: 1 to 10ro
CardShelf
.1.3.6.1.4.1.4253.2.1.7.2.1.2
fadmPerfSlotThe slot within the shelf the card is in. Valid values are: 1 to 42ro
CardSlot
.1.3.6.1.4.1.4253.2.1.7.2.1.3
fadmPerfStateThe status of the fadm card. The states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.7.2.1.4
fadmPerfStatusThe status of the fadm card. This status represents the status of the fadm card and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.7.2.1.5
fadmLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.7.2.1.6
fadmAvailTimeThe number of seconds in this time slot (15 minutes) that this fadm card has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.7.2.1.7
fadmErrFreeSecsThe number of seconds in this time slot (15 minutes) that this fadm card has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.7.2.1.8
oppmPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.8
oppmNumEventsTotal number of all traps (events) generated by all OPPM's in this time slot (15 minutes).
Counter
.1.3.6.1.4.1.4253.2.1.8.1
oppmPerfTableThis table represents the information for performance data collected for each oppm card
SEQUENCE OF OppmPerfEntry
.1.3.6.1.4.1.4253.2.1.8.2
oppmPerfEntrySpecifies the index for each row in the table below
OppmPerfEntry
.1.3.6.1.4.1.4253.2.1.8.2.1
oppmPerfLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.1.8.2.1.1
oppmPerfShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.1.8.2.1.2
oppmPerfSlotThe slot within the shelf the card is in. Valid values are: 4 to 42
CardSlot
.1.3.6.1.4.1.4253.2.1.8.2.1.3
oppmPerfStateThe state of the oppm card. The states are: online, offline.
CardState
.1.3.6.1.4.1.4253.2.1.8.2.1.4
oppmPerfStatusThe status of the oppm card. This status represents the status of the oppm card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.1.8.2.1.5
oppmLinkAStateThe state of the oppm card. The states are: linked, notLinked.
Enumeration
.1.3.6.1.4.1.4253.2.1.8.2.1.6
oppmLinkAStatusThe status of the card channel. This status represents the status of the link A of the card and in general is different from the status of the card.
Enumeration
.1.3.6.1.4.1.4253.2.1.8.2.1.7
oppmLinkBStateThe state of the oppm card link B. The states are: linked, notLinked.
Enumeration
.1.3.6.1.4.1.4253.2.1.8.2.1.8
oppmLinkBStatusThe status of the card channel. This status represents the status of the link B of the card and in general is different from the status of the card.
Enumeration
.1.3.6.1.4.1.4253.2.1.8.2.1.9
oppmLastBootTimeThe date and time of the last boot for this card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.8.2.1.10
oppmAvailTimeThe number of seconds in this time slot (15 minutes) that this oppm card has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.1.8.2.1.11
oppmErrFreeSecsThe number of seconds in this time slot (15 minutes) that this oppm card has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.1.8.2.1.12
oppmWorkingPowerworking power displayed in dBm unit
INTEGER
.1.3.6.1.4.1.4253.2.1.8.2.1.13
oppmProtectPowerprotect power displayed in dBm unit
INTEGER
.1.3.6.1.4.1.4253.2.1.8.2.1.14
mcmPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.9
mcmNumEventsTotal number of events received for all mcmt1's/mcme1's in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.9.1
mcmCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF McmCntrEntry
.1.3.6.1.4.1.4253.2.1.9.2
mcmCntrEntrySpecifies the index for each row in the table below
McmCntrEntry
.1.3.6.1.4.1.4253.2.1.9.2.1
mcmCntrLocationThe location of the mcmt1/mcme1 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmt1/mcme1 cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.9.2.1.1
mcmCntrShelfThe shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.9.2.1.2
mcmCntrSlotThe slot within the shelf the card is in. Valid values are: 1 to 21. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.9.2.1.3
mcmCntrTypeThe type of the software counter data in this row. The data is collected for the SPI data channels.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.9.2.1.4
mcmCounterFlagTurns software counters On or Off for this mcmt1/mcme1.rw
FlagType
.1.3.6.1.4.1.4253.2.1.9.2.1.5
mcmTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.2.1.6
mcmTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.2.1.7
mcmBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.2.1.8
mcmTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.2.1.9
mcmBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.2.1.10
mcmBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.2.1.11
mcmMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.2.1.12
mcmBufAllocFailNumber of buffer allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.2.1.13
mcmEcbAllocFailNumber of Event Control Block allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.2.1.14
mcmClearCntrsIf the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.9.2.1.15
mcmPerfTableThis table represents the information for performance data collected for each mcmt1/mcme1 card
SEQUENCE OF McmPerfEntry
.1.3.6.1.4.1.4253.2.1.9.3
mcmPerfEntrySpecifies the index for each row in the table below
McmPerfEntry
.1.3.6.1.4.1.4253.2.1.9.3.1
mcmPerfLocationThe location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) mcmt1/mcme1 cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.9.3.1.1
mcmPerfShelfThe shelf the card is in. Valid values are: 1 to 3ro
CardShelf
.1.3.6.1.4.1.4253.2.1.9.3.1.2
mcmPerfSlotThe slot within the shelf the card is in. Valid values are: 1 to 21ro
CardSlot
.1.3.6.1.4.1.4253.2.1.9.3.1.3
mcmPerfStateThe state of the mcmt1/mcme1 card. The states' are: online, offline, empty, loopback or diagnostics.ro
CardState
.1.3.6.1.4.1.4253.2.1.9.3.1.4
mcmPerfStatusThe status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.9.3.1.5
mcmLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.9.3.1.6
mcmAvailTimeThe number of seconds in this time slot (15 minutes) that this mcmt1/mcme1 has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.9.3.1.7
mcmErrFreeSecsThe number of seconds in this time slot (15 minutes) that this mcmt1/mcme1 has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.3.1.8
mcmBiasCurrentBias current for the optical laser. This value can be set remotelyro
INTEGER
.1.3.6.1.4.1.4253.2.1.9.3.1.9
mcmModulationThe frequency modulation for the optical laser. This value can be adjusted remotely.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.9.3.1.10
mcmApcThe APC value. This value can be set remotely.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.9.3.1.11
mcmIwmModulationThe frequency modulation for the IWM channel. This value can be adjusted remotely.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.9.3.1.12
mcmLaserOnOffThe laser On/Off flag. This value can be set remotely.ro
FlagType
.1.3.6.1.4.1.4253.2.1.9.3.1.13
mcmTemperatureThe current temperature, or the operating temperature of the optical device.ro
Gauge
.1.3.6.1.4.1.4253.2.1.9.3.1.14
mcmIntensityThe intensity of the optical light. This value can be set remotely.ro
Gauge
.1.3.6.1.4.1.4253.2.1.9.3.1.15
mcmSignalStrengthThe current signal strength for the optical path.ro
Gauge
.1.3.6.1.4.1.4253.2.1.9.3.1.16
mcmLossOfLightIf set to true, no laser light is present. If set to false, no loss of light has occurred.ro
Boolean
.1.3.6.1.4.1.4253.2.1.9.3.1.17
mcmSignalDetectIf set to true, signal is detected. If set to false, no signal is present.ro
Boolean
.1.3.6.1.4.1.4253.2.1.9.3.1.18
mcmPortCurrTableThis table represents the information for each MCMT1/MCME1 port's current counters.
SEQUENCE OF McmPortCurrEntry
.1.3.6.1.4.1.4253.2.1.9.4
mcmPortCurrEntrySpecifies the index for each row in the table below
McmPortCurrEntry
.1.3.6.1.4.1.4253.2.1.9.4.1
mcmPortCurrCardLocationLocation of the MCMT1/MCME1 port. Valid values are: Local in the same chassis, or remote to this chassisro
CardLocation
.1.3.6.1.4.1.4253.2.1.9.4.1.1
mcmPortCurrCardShelfThe shelf the card is in. Valid values are: 2..3.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.9.4.1.2
mcmPortCurrCardSlotThe slot within the shelf the Module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.9.4.1.3
mcmPortCurrIndexPort's index.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.9.4.1.4
mcmPortCurrASsMCMT1/MCME1 port's ASs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.4.1.5
mcmPortCurrFrameASsMCMT1/MCME1 port's FrameASs counter less than 15 mins.
Counter
.1.3.6.1.4.1.4253.2.1.9.4.1.6
mcmPortCurrFEsMCMT1/MCME1 port's FEs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.4.1.7
mcmPortCurrCRCErrsMCMT1/MCME1 port's CRC errs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.4.1.8
mcmPortCurrSESsMCMT1/MCME1 port's SESs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.4.1.9
mcmPortCurrSEFSsMCMT1/MCME1 port's SEFSs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.4.1.10
mcmPortCurrUASsMCMT1/MCME1 port's UASs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.4.1.11
mcmPortCurrLESsMCMT1/MCME1 port's LESs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.4.1.12
mcmPortCurrBESsMCMT1/MCME1 port's BESs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.4.1.13
mcmPortCurrDMsMCMT1/MCME1 port's DMSs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.4.1.14
mcmPortCurrLCVsMCMT1/MCME1 port's LCVs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.1.9.4.1.15
fnPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.10
fnNumEventsTotal number of all traps (events) generated by all Fans in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.10.1
fnPerfTableThis table represents the information for performance data collected for each fan module.
SEQUENCE OF FnPerfEntry
.1.3.6.1.4.1.4253.2.1.10.2
fnPerfEntrySpecifies the index for each row in the table below
FnPerfEntry
.1.3.6.1.4.1.4253.2.1.10.2.1
fnPerfIDThe module ID where the fan module is plugged in.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.10.2.1.1
fnPerfStateThe state of the fan module.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.10.2.1.2
fnPerfStatusThe status of the fan module. This status represents the status of the fan module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.10.2.1.3
csimPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.11
csimNumEventsThis variable keeps track of the number of events related to ColorSIM. The reason this has been made obsolete is that all colorsim related events would eventually be part of ocm events
Counter
.1.3.6.1.4.1.4253.2.1.11.1
csimCurrentTableThis table represents the information for each colorsim card in the most current interval
SEQUENCE OF CsimCurrentEntry
.1.3.6.1.4.1.4253.2.1.11.2
csimCurrentEntrySpecifies the index for each row in the table below.
CsimCurrentEntry
.1.3.6.1.4.1.4253.2.1.11.2.1
csimCurrentLocationLocation of the ColorSIM modulero
CardLocation
.1.3.6.1.4.1.4253.2.1.11.2.1.1
csimCurrentShelfThe shelf of the ColorSIM modulero
CardShelf
.1.3.6.1.4.1.4253.2.1.11.2.1.2
csimCurrentSlotThe Slot of the ColorSIM modulero
CardSlot
.1.3.6.1.4.1.4253.2.1.11.2.1.3
csimCurrentEFIsThe counter associated with the number of Error Free Interval Counts in the current update (default: 15 minutes) interval.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.11.2.1.4
csimCurrentEIsThe counter associated with the number of Errored Interval Counts in the current update (default: 15 minutes) interval.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.11.2.1.5
csimCurrentSEIsThe counter associated with the number of Severly Errored Interval Counts in the current update (default:15 minutes) interval.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.11.2.1.6
csimCurrentBERsThe counter associated with the number of Bit Error Rates Counts in the current update (default: 15 minutes) interval. The unit will be in the form of x.ye-z.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.11.2.1.7
csimCurrentUAIsThe counter associated with the number of Unavailable Interval Counts in the current update (default: 15 minutes) interval.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.11.2.1.8
csimCurrentGIsThe number of gating intervals over which the data was collected.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.11.2.1.9
csimCurrentDateTimeTime in seconds elasped since 01/01/1970 00:00:00 GMT. Assuming local time is same as GMTro
INTEGER
.1.3.6.1.4.1.4253.2.1.11.2.1.10
rpsmPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.12
rpsmNumEventsTotal number of all traps (events) generated by all RPSM's in this time slot (15 minutes).
Counter
.1.3.6.1.4.1.4253.2.1.12.1
rpsmPerfTableThis table represents the information for performance data collected for each rpsm card
SEQUENCE OF RpsmPerfEntry
.1.3.6.1.4.1.4253.2.1.12.2
rpsmPerfEntrySpecifies the index for each row in the table below
RpsmPerfEntry
.1.3.6.1.4.1.4253.2.1.12.2.1
rpsmPerfLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.1.12.2.1.1
rpsmPerfShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.1.12.2.1.2
rpsmPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.1.12.2.1.3
rpsmPerfStateThe state of the rpsm card. The possible states are: online, offline, empty, loopback or diag.
CardState
.1.3.6.1.4.1.4253.2.1.12.2.1.4
rpsmPerfStatusThe status of the rpsm card. This status represents the status of the rpsm card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.1.12.2.1.5
rpsmLinkEastStateThe link state of path East, whether light is being detected. The states are: linked, notLinked.
Enumeration
.1.3.6.1.4.1.4253.2.1.12.2.1.6
rpsmLinkEastStatusThe status of the card channel. This status represents the status of the link East of the card and in general is different from the status of the card.
Enumeration
.1.3.6.1.4.1.4253.2.1.12.2.1.7
rpsmLinkWestStateThe link state of path West, whether light is being detected. The states are: linked, notLinked.
Enumeration
.1.3.6.1.4.1.4253.2.1.12.2.1.8
rpsmLinkWestStatusThe status of the card channel. This status represents the status of the link West of the card and in general is different from the status of the card.
Enumeration
.1.3.6.1.4.1.4253.2.1.12.2.1.9
rpsmLastBootTimeThe date and time of the last boot for this card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.12.2.1.10
rpsmAvailTimeThe number of seconds in this time slot (15 minutes) that this rpsm has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.1.12.2.1.11
rpsmErrFreeSecsThe number of seconds in this time slot (15 minutes) that this rpsm has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.1.12.2.1.12
rpsmWorkingPowerWorking link power of the RPSM card in dBm.
INTEGER
.1.3.6.1.4.1.4253.2.1.12.2.1.13
rpsmProtectionPowerProtection link power of the RPSM card in dBm.
INTEGER
.1.3.6.1.4.1.4253.2.1.12.2.1.14
rsdmPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.13
rsdmNumEventsTotal number of all traps (events) generated by all RSDM's in this time slot (15 minutes).
Counter
.1.3.6.1.4.1.4253.2.1.13.1
rsdmPerfTableThis table represents the information for performance data collected for each rsdm card
SEQUENCE OF RsdmPerfEntry
.1.3.6.1.4.1.4253.2.1.13.2
rsdmPerfEntrySpecifies the index for each row in the table below
RsdmPerfEntry
.1.3.6.1.4.1.4253.2.1.13.2.1
rsdmPerfLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.1.13.2.1.1
rsdmPerfShelfThe shelf the card is in.
CardShelf
.1.3.6.1.4.1.4253.2.1.13.2.1.2
rsdmPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.1.13.2.1.3
rsdmPerfStateThe state of the rsdm card. The states are: online, offline.
CardState
.1.3.6.1.4.1.4253.2.1.13.2.1.4
rsdmPerfStatusThe status of the rsdm card. This status represents the status of the rsdm card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.1.13.2.1.5
rsdmLinkEastStateThe link state of path A, whether light is being detected. The states are: linked, notLinked.
Enumeration
.1.3.6.1.4.1.4253.2.1.13.2.1.6
rsdmLinkEastStatusThe status of the card channel. This status represents the status of the link East of the card and in general is different from the status of the card.
Enumeration
.1.3.6.1.4.1.4253.2.1.13.2.1.7
rsdmLinkWestStateThe link state of path West, whether light is being detected. The states are: linked, notLinked.
Enumeration
.1.3.6.1.4.1.4253.2.1.13.2.1.8
rsdmLinkWestStatusThe status of the card channel. This status represents the status of the link West of the card and in general is different from the status of the card.
Enumeration
.1.3.6.1.4.1.4253.2.1.13.2.1.9
rsdmLastBootTimeThe date and time of the last boot for this card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.13.2.1.10
rsdmAvailTimeThe number of seconds in this time slot (15 minutes) that this rsdm card has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.1.13.2.1.11
rsdmErrFreeSecsThe number of seconds in this time slot (15 minutes) that this rsdm card has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.1.13.2.1.12
rsdmWorkingPowerWorking link power of the RSDM card in dBm.
INTEGER
.1.3.6.1.4.1.4253.2.1.13.2.1.13
rsdmProtectionPowerProtection link power of the RSDM card in dBm.
INTEGER
.1.3.6.1.4.1.4253.2.1.13.2.1.14
rtdmPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.14
rtdmNumEventsTotal number of all traps (events) generated by all RTDM's in this time slot (15 minutes).
Counter
.1.3.6.1.4.1.4253.2.1.14.1
rtdmPerfTableThis table represents the information for performance data collected for each rtdm card
SEQUENCE OF RtdmPerfEntry
.1.3.6.1.4.1.4253.2.1.14.2
rtdmPerfEntrySpecifies the index for each row in the table below
RtdmPerfEntry
.1.3.6.1.4.1.4253.2.1.14.2.1
rtdmPerfLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.1.14.2.1.1
rtdmPerfShelfThe shelf the card is in.
CardShelf
.1.3.6.1.4.1.4253.2.1.14.2.1.2
rtdmPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.1.14.2.1.3
rtdmPerfStateThe state of the rtdm card. The states are: online, offline, empty, loopback or diag.
CardState
.1.3.6.1.4.1.4253.2.1.14.2.1.4
rtdmPerfStatusThe status of the rtdm card. This status represents the status of the rtdm card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.1.14.2.1.5
rtdmLastBootTimeThe date and time of the last boot for this card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.14.2.1.6
rtdmAvailTimeThe number of seconds in this time slot (15 minutes) that this rtdm has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.1.14.2.1.7
rtdmErrFreeSecsThe number of seconds in this time slot (15 minutes) that this rtdm has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.1.14.2.1.8
osamPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.15
osamNumEventsTotal number of events received for all osam's in the most current 15 minutes slot.ro
Counter
.1.3.6.1.4.1.4253.2.1.15.1
osamCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF OsamCntrEntry
.1.3.6.1.4.1.4253.2.1.15.2
osamCntrEntrySpecifies the index for each row in the table below
OsamCntrEntry
.1.3.6.1.4.1.4253.2.1.15.2.1
osamCntrLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.15.2.1.1
osamCntrShelfThe shelf number in which the module is plugged in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.15.2.1.2
osamCntrSlotThe slot number in which the module is plugged in.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.15.2.1.3
osamCntrKeepAlivePktSentThe total number of keep alive packets sent.ro
Counter
.1.3.6.1.4.1.4253.2.1.15.2.1.4
osamCntrKeepAlivePktRcvdThe total number of keep alive packets received.ro
Counter
.1.3.6.1.4.1.4253.2.1.15.2.1.5
osamCntrKeepAliveBadPktRcvdThe total number of bad keep alive data packets received.ro
Counter
.1.3.6.1.4.1.4253.2.1.15.2.1.6
osamPerfTableThis table represents the information for performance data collected for each osam card
SEQUENCE OF OsamPerfEntry
.1.3.6.1.4.1.4253.2.1.15.3
osamPerfEntrySpecifies the index for each row in the table below
OsamPerfEntry
.1.3.6.1.4.1.4253.2.1.15.3.1
osamPerfLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.15.3.1.1
osamPerfShelfThe shelf number in which the module is plugged in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.15.3.1.2
osamPerfSlotThe slot number in which the module is plugged in.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.15.3.1.3
osamPerfStateThe current state of the module.ro
CardState
.1.3.6.1.4.1.4253.2.1.15.3.1.4
osamPerfStatusThe current alarm status of the channel.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.15.3.1.5
osamPerfLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.6
osamPerfAvailTimeThe number of seconds in the most current 15 minutes interval that this module has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.1.15.3.1.7
osamPerfErrFreeSecsThe number of seconds in the most current 15 minutes interval that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.15.3.1.8
osamPerfAprStatusThe status of the automatic power reduction mode. Not applicable to OSAM-HP/LP modulero
FlagType
.1.3.6.1.4.1.4253.2.1.15.3.1.9
osamPerfInputPowerThe power at the input in dBm. Not applicable to OSAM-HP/LP modulero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.10
osamPerfBFDPowerThe back facet diode reading in the pump laser; related to the power output of the pump laser. This values isn't calibrated and doesn't have a unit. Not applicable to OSAM-HP/LP modulero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.11
osamPerfOutputPowerThe power at the output port in dBm.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.12
osamPerfAPRDetector1PowerThe automatic power reduction detector 1 reading in dBm. Two readings are provided for redundancy purposes. Not applicable to OSAM-HP/LP modulero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.13
osamPerfAPRDetector2PowerThe automatic power reduction detector 2 reading in dBm. Two readings are provided for redundancy purposes. Not applicable to OSAM-HP/LP modulero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.14
osamPerfLaserTemperatureThe pump laser temperature in degree Celsius. Not applicable to OSAM-HP/LP modulero
INTEGER
.1.3.6.1.4.1.4253.2.1.15.3.1.15
osamPerfTecCurrentThe Thermo-Electric Cooler current in mA. Not applicable to OSAM-HP/LP modulero
INTEGER
.1.3.6.1.4.1.4253.2.1.15.3.1.16
osamPerfBiasCurrentThe measured pump laser bias current in mA. Not applicable to OSAM-HP/LP modulero
INTEGER
.1.3.6.1.4.1.4253.2.1.15.3.1.17
osamPerfAmplifierGainThe measured overall amplifier gain in dB.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.18
osamPerfPCBTemperatureThe temperature of the printed circuit board in degree Celsius.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.15.3.1.19
osam2PerfPump1BFDPowerThe back facet diode reading in pump 1 laser; related to the power output of the pump laser. Unit to represent the value is DAC (Digital to Analog converter)ro
INTEGER
.1.3.6.1.4.1.4253.2.1.15.3.1.20
osam2PerfPump2BFDPowerThe back facet diode reading in pump 2 laser; related to the power output of the pump laser. Unit to represent the value is DAC (Digital to Analog converter). Applicable only for OSAM-HP modulero
INTEGER
.1.3.6.1.4.1.4253.2.1.15.3.1.21
osam2PerfPump1IBiasIndicates the bias current of Pump 1 in mA. The range of values of bias current range from 40 mA - barely turning on, to MaxIbias - maximum operating current recommended by the manufacturer. Pump IBias is used internally to set off alarms and to indicate the health of the module.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.15.3.1.22
osam2PerfPump2IBiasIndicates the bias current of Pump 2 in mA. The range of values of bias current range from 40 mA - barely turning on, to MaxIbias - maximum operating current recommended by the manufacturer. Pump IBias is used internally to set off alarms and to indicate the health of the module. Applicable only for OSAM-HP modulero
INTEGER
.1.3.6.1.4.1.4253.2.1.15.3.1.23
osam2PerfPump1ITECIndicates the current level in mA of Thermal Electric Cooler (TEC) used for cooling laser pump 1.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.15.3.1.24
osam2PerfPump2ITECIndicates the current level in mA of Thermal Electric Cooler (TEC) used for cooling laser pump 2. Applicable only for OSAM-HPro
INTEGER
.1.3.6.1.4.1.4253.2.1.15.3.1.25
osam2PerfPump1TempLaser pump (#1) temperature in degree celciusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.26
osam2PerfPump2TempLaser pump (#2) temperature in degree celcius Applicable only for OSAM-HP modulero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.27
osam2PerfGBInputPowerGain block input power in dBm.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.28
osam2PerfGBOutputPowerGain block output power in dBm with attenuation set to zero.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.29
osam2PerfAttenuationIndicates optical attenuation in dB imposed by variable optical attenuator(VOA)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.15.3.1.30
rsmPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.16
rsmNumEventsTotal number of all traps (events) generated by all RSM's in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.16.1
rsmPerfTableThis table represents the information for performance data collected for each rsm card
SEQUENCE OF RsmPerfEntry
.1.3.6.1.4.1.4253.2.1.16.2
rsmPerfEntrySpecifies the index for each row in the table below
RsmPerfEntry
.1.3.6.1.4.1.4253.2.1.16.2.1
rsmPerfLocationThe location of the card.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.16.2.1.1
rsmPerfShelfThe shelf the card is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.16.2.1.2
rsmPerfSlotThe slot within the shelf the card is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.16.2.1.3
rsmPerfStateThe state of the rsm card. The possible states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.16.2.1.4
rsmPerfStatusThe status of the rsm card. This status represents the status of the rsm card and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.16.2.1.5
rsmLinkAStateThe link state of path A (East), whether light is being detected. The states are: linked, notLinked.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.16.2.1.6
rsmLinkAStatusThe status of the card channel. This status represents the status of the link A (East) of the card and in general is different from the status of the card.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.16.2.1.7
rsmLinkBStateThe link state of path B (West), whether light is being detected. The states are: linked, notLinked.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.16.2.1.8
rsmLinkBStatusThe status of the card channel. This status represents the status of the link B (West) of the card and in general is different from the status of the card.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.16.2.1.9
rsmLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.16.2.1.10
rsmAvailTimeThe number of seconds in this time slot (15 minutes) that this rsm has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.16.2.1.11
rsmErrFreeSecsThe number of seconds in this time slot (15 minutes) that this rsm has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.16.2.1.12
rsmWorkingPowerWorking link power of the RSM card in dBm.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.16.2.1.13
rsmProtectionPowerProtection link power of the RSM card in dBm.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.16.2.1.14
upsmPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.17
upsmNumEventsTotal number of all traps (events) generated by all UPSM's in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.17.1
upsmPerfTableThis table represents the information for performance data collected for each upsm card
SEQUENCE OF UpsmPerfEntry
.1.3.6.1.4.1.4253.2.1.17.2
upsmPerfEntrySpecifies the index for each row in the table below
UpsmPerfEntry
.1.3.6.1.4.1.4253.2.1.17.2.1
upsmPerfLocationThe location of the card.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.17.2.1.1
upsmPerfShelfThe shelf the card is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.17.2.1.2
upsmPerfSlotThe slot within the shelf the card is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.17.2.1.3
upsmPerfStateThe state of the upsm card. The possible states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.17.2.1.4
upsmPerfStatusThe status of the upsm card. This status represents the status of the upsm card and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.17.2.1.5
upsmLinkAStateThe link state of path A (East), whether light is being detected. The states are: linked, notLinked.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.17.2.1.6
upsmLinkAStatusThe status of the card channel. This status represents the status of the link A (East) of the card and in general is different from the status of the card.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.17.2.1.7
upsmLinkBStateThe link state of path B (West), whether light is being detected. The states are: linked, notLinked.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.17.2.1.8
upsmLinkBStatusThe status of the card channel. This status represents the status of the link B (West) of the card and in general is different from the status of the card.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.17.2.1.9
upsmLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.17.2.1.10
upsmAvailTimeThe number of seconds in this time slot (15 minutes) that this upsm has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.17.2.1.11
upsmErrFreeSecsThe number of seconds in this time slot (15 minutes) that this upsm has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.17.2.1.12
upsmWorkingPowerWorking link power of the UPSM card in dBm.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.17.2.1.13
upsmProtectionPowerProtection link power of the UPSM card in dBm.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.17.2.1.14
mcmescPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.18
mcmescNumEventsTotal number of events received for all mcmesc's in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.18.1
mcmescCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF McmescCntrEntry
.1.3.6.1.4.1.4253.2.1.18.2
mcmescCntrEntrySpecifies the index for each row in the table below
McmescCntrEntry
.1.3.6.1.4.1.4253.2.1.18.2.1
mcmescCntrLocationThe location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.18.2.1.1
mcmescCntrShelfThe shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.18.2.1.2
mcmescCntrSlotThe slot within the shelf the card is in. Valid values are: 1 to 21. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.18.2.1.3
mcmescCntrTypeThe type of the software counter data in this row. The data is collected for the SPI data channels.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.18.2.1.4
mcmescCounterFlagTurns software counters On or Off for this mcmesc.rw
FlagType
.1.3.6.1.4.1.4253.2.1.18.2.1.5
mcmescTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.18.2.1.6
mcmescTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.18.2.1.7
mcmescBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.18.2.1.8
mcmescTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.18.2.1.9
mcmescBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.18.2.1.10
mcmescBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.18.2.1.11
mcmescMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.18.2.1.12
mcmescClearCntrsIf the value is reset, all software counters are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.18.2.1.13
mcmescPerfTableThis table represents the information for performance data collected for each mcmesc card
SEQUENCE OF McmescPerfEntry
.1.3.6.1.4.1.4253.2.1.18.3
mcmescPerfEntrySpecifies the index for each row in the table below
McmescPerfEntry
.1.3.6.1.4.1.4253.2.1.18.3.1
mcmescPerfLocationThe location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) mcmesc cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.18.3.1.1
mcmescPerfShelfThe shelf the card is in. Valid values are: 1 to 3ro
CardShelf
.1.3.6.1.4.1.4253.2.1.18.3.1.2
mcmescPerfSlotThe slot within the shelf the card is in. Valid values are: 1 to 21ro
CardSlot
.1.3.6.1.4.1.4253.2.1.18.3.1.3
mcmescPerfStateThe state of the mcmesc card. The states' are: online, offline, empty, loopback or diagnostics.ro
CardState
.1.3.6.1.4.1.4253.2.1.18.3.1.4
mcmescPerfStatusThe status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.18.3.1.5
mcmescLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.3.1.6
mcmescAvailTimeThe number of seconds in this time slot (15 minutes) that this mcmesc has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.18.3.1.7
mcmescPortCurrTableThis table represents the information for each mcmesc cpe port's current counters.
SEQUENCE OF McmescPortCurrEntry
.1.3.6.1.4.1.4253.2.1.18.4
mcmescPortCurrEntrySpecifies the index for each row in the table below
McmescPortCurrEntry
.1.3.6.1.4.1.4253.2.1.18.4.1
mcmescPortCurrCardLocationLocation of the MCMESC CPE port. Valid values are: Local in the same chassis, or remote to this chassisro
CardLocation
.1.3.6.1.4.1.4253.2.1.18.4.1.1
mcmescPortCurrCardShelfThe shelf the card is in. Valid values are: 2..3.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.18.4.1.2
mcmescPortCurrCardSlotThe slot within the shelf the Module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.18.4.1.3
mcmescPortCurrPortCPE port's index.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.18.4.1.4
mcmescPortCurrRxSigCPE port's receive signal power.ro
DisplayString
.1.3.6.1.4.1.4253.2.1.18.4.1.5
mcmescPortCurrDurationmcmesc CPE port's current ongoing interval duration.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.4.1.6
mcmescPortCurrEnsmcmesc CPE port's enabled seconds during current ongoing interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.4.1.7
mcmescPortCurrLossmcmesc CPE port's loss of signal seconds during current ongoing interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.4.1.8
mcmescPortCurrCrcErrmcmesc CPE port's CRC error counter during current ongoing interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.4.1.9
mcmescPortCurrOobErrmcmesc CPE port's Out-Of-Band error counter during current ongoing interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.4.1.10
mcmescPortCurrRdpErrmcmesc CPE port's Running Disparity error counter during current ongoing interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.4.1.11
mcmescPortCurrBermcmesc CPE port's BER, in the form of x.yE-z.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.4.1.12
mcmescLinkCurrTableThis table represents the information for each mcmesc cpe port's current counters.
SEQUENCE OF McmescLinkCurrEntry
.1.3.6.1.4.1.4253.2.1.18.5
mcmescLinkCurrEntrySpecifies the index for each row in the table below
McmescLinkCurrEntry
.1.3.6.1.4.1.4253.2.1.18.5.1
mcmescLinkCurrCardLocationLocation of the MCMESC CPE port. Valid values are: Local in the same chassis, or remote to this chassisro
CardLocation
.1.3.6.1.4.1.4253.2.1.18.5.1.1
mcmescLinkCurrCardShelfThe shelf the card is in. Valid values are: 2..3.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.18.5.1.2
mcmescLinkCurrCardSlotThe slot within the shelf the Module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.18.5.1.3
mcmescLinkCurrRxSigLink port's receive signal power.ro
DisplayString
.1.3.6.1.4.1.4253.2.1.18.5.1.4
mcmescLinkCurrDurationmcmesc LINK port's current ongoing interval duration.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.5.1.5
mcmescLinkCurrTsosmcmesc LINK port's test-sequence on seconds during current ongoing interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.5.1.6
mcmescLinkCurrLossmcmesc LINK port's loss of signal seconds during current ongoing interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.5.1.7
mcmescLinkCurrCrcErrmcmesc LINK port's CRC error counter during current ongoing interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.5.1.8
mcmescLinkCurrOobErrmcmesc LINK port's Out-Of-Band error counter during current ongoing interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.5.1.9
mcmescLinkCurrRdpErrmcmesc LINK port's Running Disparity error counter during current ongoing interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.5.1.10
mcmescLinkCurrBermcmesc LINK port's BER, in the form of x.yE-z.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.18.5.1.11
routingPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.21
imnRoutingPerfTableThis table represents the information for performance data collected for each route
SEQUENCE OF ImnRoutingPerfEntry
.1.3.6.1.4.1.4253.2.1.21.1
imnRoutingPerfEntrySpecifies the index for each row in the table below
ImnRoutingPerfEntry
.1.3.6.1.4.1.4253.2.1.21.1.1
imnRoutePerfIpDestDestination IP address. Not supported for remote TMM masters.ro
IpAddress
.1.3.6.1.4.1.4253.2.1.21.1.1.1
imnRoutePerfStatusIs the route active, comatose or deadro
Enumeration
.1.3.6.1.4.1.4253.2.1.21.1.1.2
tapPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.22
tapNumEventsTotal number of all traps (events) generated by all TAP modules in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.22.1
tapPerfTableThis table represents the information for performance data collected for each TAP module.
SEQUENCE OF TapPerfEntry
.1.3.6.1.4.1.4253.2.1.22.2
tapPerfEntrySpecifies the index for each row in the table below
TapPerfEntry
.1.3.6.1.4.1.4253.2.1.22.2.1
tapPerfLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.22.2.1.1
tapPerfShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.22.2.1.2
tapPerfSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.22.2.1.3
tapTypeModule type.ro
CardType
.1.3.6.1.4.1.4253.2.1.22.2.1.4
tapPerfStateThe state of the TAP module. The states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.22.2.1.5
tapPerfStatusThe status of the TAP module. This status represents the status of the TAP module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.22.2.1.6
tapLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.22.2.1.7
tapAvailTimeThe number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.22.2.1.8
tapErrFreeSecsThe number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.22.2.1.9
voadmPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.23
voadmNumEventsTotal number of all traps (events) generated by all VOADM modules in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.23.1
voadmPerfTableThis table represents the information for performance data collected for each VOADM module.
SEQUENCE OF VoadmPerfEntry
.1.3.6.1.4.1.4253.2.1.23.2
voadmPerfEntrySpecifies the index for each row in the table below
VoadmPerfEntry
.1.3.6.1.4.1.4253.2.1.23.2.1
voadmPerfLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.23.2.1.1
voadmPerfShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.23.2.1.2
voadmPerfSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.23.2.1.3
voadmTypeModule type.ro
CardType
.1.3.6.1.4.1.4253.2.1.23.2.1.4
voadmPerfStateThe state of the VOADM module. The states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.23.2.1.5
voadmPerfStatusThe status of the VOADM module. This status represents the status of the VOADM module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.23.2.1.6
voadmLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.23.2.1.7
voadmAvailTimeThe number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.23.2.1.8
voadmErrFreeSecsThe number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.23.2.1.9
dmmPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.24
dmmNumEventsTotal number of all traps (events) generated by all DMM modules in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.24.1
dmmPerfTableThis table represents the information for performance data collected for each DMM module.
SEQUENCE OF DmmPerfEntry
.1.3.6.1.4.1.4253.2.1.24.2
dmmPerfEntrySpecifies the index for each row in the table below
DmmPerfEntry
.1.3.6.1.4.1.4253.2.1.24.2.1
dmmPerfLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.24.2.1.1
dmmPerfShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.24.2.1.2
dmmPerfSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.24.2.1.3
dmmPerfStateThe state of the DMM module. The states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.24.2.1.4
dmmPerfStatusThe status of the DMM module. This status represents the status of the DMM module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.24.2.1.5
dmmLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.24.2.1.6
dmmAvailTimeThe number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.24.2.1.7
dmmErrFreeSecsThe number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.24.2.1.8
dmmCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF DmmCntrEntry
.1.3.6.1.4.1.4253.2.1.24.3
dmmCntrEntrySpecifies the index for each row in the table below
DmmCntrEntry
.1.3.6.1.4.1.4253.2.1.24.3.1
dmmCntrLocationThe location of the DMM card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known DMM cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.24.3.1.1
dmmCntrShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) DMM cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.24.3.1.2
dmmCntrSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) DMM cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.24.3.1.3
dmmCntrTypeThe type of the software counter data in this row.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.24.3.1.4
dmmTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.24.3.1.5
dmmTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.24.3.1.6
dmmTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.24.3.1.7
dmmBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.24.3.1.8
dmmBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.24.3.1.9
dmmBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.24.3.1.10
dmmMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.24.3.1.11
dmmClearCntrsIf the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.24.3.1.12
dmmPmTableThis table represents the information for each entry for the software counters.
SEQUENCE OF DmmPmEntry
.1.3.6.1.4.1.4253.2.1.24.4
dmmPmEntrySpecifies the index for each row in the table below
DmmPmEntry
.1.3.6.1.4.1.4253.2.1.24.4.1
dmmPmLocationThe location of the DMM card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known DMM cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.24.4.1.1
dmmPmShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) DMM cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.24.4.1.2
dmmPmSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) DMM cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.24.4.1.3
dmmPmTypeThe type of the software counter data in this row.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.24.4.1.4
dmmPmErrorsThe number of packets errors since port last came online.ro
Counter
.1.3.6.1.4.1.4253.2.1.24.4.1.5
dmmPmErredSecsThe number of erred seconds since port last came online.ro
Counter
.1.3.6.1.4.1.4253.2.1.24.4.1.6
dmmStartTimeThe date/time the port came last online.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.24.4.1.7
dmmClearPmCntrsIf the value is reset, all PM counters for this port are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.24.4.1.8
dmmPmRxPowerPort receive power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.24.4.1.9
dmmPmTxPowerPort receive power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.24.4.1.10
ocm10gfPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.25
ocm10gfNumEventsTotal number of all traps (events) generated by all OCM10GF modules in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.25.1
ocm10gfPerfTableThis table represents the information for performance data collected for each OCM10GF module.
SEQUENCE OF Ocm10gfPerfEntry
.1.3.6.1.4.1.4253.2.1.25.2
ocm10gfPerfEntrySpecifies the index for each row in the table below
Ocm10gfPerfEntry
.1.3.6.1.4.1.4253.2.1.25.2.1
ocm10gfPerfLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.25.2.1.1
ocm10gfPerfShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.25.2.1.2
ocm10gfPerfSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.25.2.1.3
ocm10gfPerfStateThe state of the OCM10GF module. The states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.25.2.1.4
ocm10gfPerfStatusThe status of the OCM10GF module. This status represents the status of the OCM10GF module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.25.2.1.5
ocm10gfLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.2.1.6
ocm10gfAvailTimeThe number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.25.2.1.7
ocm10gfErrFreeSecsThe number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.25.2.1.8
ocm10gfCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF Ocm10gfCntrEntry
.1.3.6.1.4.1.4253.2.1.25.3
ocm10gfCntrEntrySpecifies the index for each row in the table below
Ocm10gfCntrEntry
.1.3.6.1.4.1.4253.2.1.25.3.1
ocm10gfCntrLocationThe location of the OCM10GF card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM10GF cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.25.3.1.1
ocm10gfCntrShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.25.3.1.2
ocm10gfCntrSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.25.3.1.3
ocm10gfCntrTypeThe type of the software counter data in this row.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.25.3.1.4
ocm10gfTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.25.3.1.5
ocm10gfTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.25.3.1.6
ocm10gfTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.25.3.1.7
ocm10gfBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.25.3.1.8
ocm10gfBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.25.3.1.9
ocm10gfBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.25.3.1.10
ocm10gfMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.25.3.1.11
ocm10gfClearCntrsIf the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.25.3.1.12
ocm10gfPmTableThis table represents the information for each entry for the software counters.
SEQUENCE OF Ocm10gfPmEntry
.1.3.6.1.4.1.4253.2.1.25.4
ocm10gfPmEntrySpecifies the index for each row in the table below
Ocm10gfPmEntry
.1.3.6.1.4.1.4253.2.1.25.4.1
ocm10gfPmLocationThe location of the OCM10GF card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM10GF cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.25.4.1.1
ocm10gfPmShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.25.4.1.2
ocm10gfPmSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.25.4.1.3
ocm10gfPmNumIntervalsro
INTEGER
.1.3.6.1.4.1.4253.2.1.25.4.1.4
ocm10gfPmLinkRxPwrro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.5
ocm10gfPmLinkTxPwrro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.6
ocm10gfPmLinkFecErrorsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.7
ocm10gfPmLinkUncorrectedFecErrsro
Counter
.1.3.6.1.4.1.4253.2.1.25.4.1.8
ocm10gfPmLinkCorrectedFecErrsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.9
ocm10gfPmLinkCorrectedOnesErrro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.10
ocm10gfPmLinkErredSecondsro
Counter
.1.3.6.1.4.1.4253.2.1.25.4.1.11
ocm10gfPmCpeRxPwrro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.12
ocm10gfPmCpeTxPwrro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.13
ocm10gfPmCpeSonetRxB2Errsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.14
ocm10gfPmCpeSonetTxB2Errsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.15
ocm10gfPmCpe10GbeRxTotalPktsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.16
ocm10gfPmCpe10GbeRxErredPktsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.17
ocm10gfPmCpe10GbeTxTotalPktsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.18
ocm10gfPmCpe10gbeTxErredPktsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.25.4.1.19
ocm10gfPmCpeErredSecondsro
Counter
.1.3.6.1.4.1.4253.2.1.25.4.1.20
ocm10gfClearPmCntrsIf the value is reset, all PM counters for this port are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.25.4.1.21
ocm2Perf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.26
ocm2NumEventsTotal number of all traps (events) generated by all OCM2 modules in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.26.1
ocm2PerfTableThis table represents the information for performance data collected for each OCM2 module.
SEQUENCE OF Ocm2PerfEntry
.1.3.6.1.4.1.4253.2.1.26.2
ocm2PerfEntrySpecifies the index for each row in the table below
Ocm2PerfEntry
.1.3.6.1.4.1.4253.2.1.26.2.1
ocm2PerfLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.26.2.1.1
ocm2PerfShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.26.2.1.2
ocm2PerfSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.26.2.1.3
ocm2PerfStateThe state of the OCM2 module. The states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.26.2.1.4
ocm2PerfStatusThe status of the OCM2 module. This status represents the status of the OCM2 module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.26.2.1.5
ocm2LastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.26.2.1.6
ocm2AvailTimeThe number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.26.2.1.7
ocm2ErrFreeSecsThe number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.26.2.1.8
ocm2CntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF Ocm2CntrEntry
.1.3.6.1.4.1.4253.2.1.26.3
ocm2CntrEntrySpecifies the index for each row in the table below
Ocm2CntrEntry
.1.3.6.1.4.1.4253.2.1.26.3.1
ocm2CntrLocationThe location of the OCM2 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM2 cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.26.3.1.1
ocm2CntrShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM2 cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.26.3.1.2
ocm2CntrSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM2 cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.26.3.1.3
ocm2CntrTypeThe type of the software counter data in this row.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.26.3.1.4
ocm2TotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.26.3.1.5
ocm2TotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.26.3.1.6
ocm2TotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.26.3.1.7
ocm2BadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.26.3.1.8
ocm2BytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.26.3.1.9
ocm2BytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.26.3.1.10
ocm2MsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.26.3.1.11
ocm2ClearCntrsIf the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.26.3.1.12
ocm2PmTableThis table represents the information for each entry for the software counters.
SEQUENCE OF Ocm2PmEntry
.1.3.6.1.4.1.4253.2.1.26.4
ocm2PmEntrySpecifies the index for each row in the table below
Ocm2PmEntry
.1.3.6.1.4.1.4253.2.1.26.4.1
ocm2PmLocationThe location of the OCM2 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM2 cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.26.4.1.1
ocm2PmShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM2 cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.26.4.1.2
ocm2PmSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM2 cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.26.4.1.3
ocm2PmLinkRxPwrLink receive power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.26.4.1.5
ocm2PmLinkTxPwrLink transmit power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.26.4.1.6
ocm2PmCpeRxPwrCPE receive power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.26.4.1.7
ocm2PmCpeTxPwrCPE transmit power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.26.4.1.8
ocm2PmNumLinkRxIntervalsThe of intervals (seconds) over which the link Rx statistics have been accumulated.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.26.4.1.9
ocm2PmLinkRxErrorsLink receive errors.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.26.4.1.10
ocm2PmLinkRxErredSecondsLink receive errored seconds.ro
Counter
.1.3.6.1.4.1.4253.2.1.26.4.1.11
ocm2PmNumCpeRxIntervalsThe of intervals (seconds) over which the CPE Rx statistics have been accumulated.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.26.4.1.12
ocm2PmCpeRxErrorsCPE receive errors.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.26.4.1.13
ocm2PmCpeRxErredSecondsCPE receive errored seconds.ro
Counter
.1.3.6.1.4.1.4253.2.1.26.4.1.14
ocm2PmNumCpeTxIntervalsThe of intervals (seconds) over which the CPE Tx statistics have been accumulated.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.26.4.1.15
ocm2PmCpeTxErrorsCPE transmit errors.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.26.4.1.16
ocm2PmCpeTxErredSecondsCPE transmit errored seconds.ro
Counter
.1.3.6.1.4.1.4253.2.1.26.4.1.17
ocm2ClearPmCntrsIf the value is reset, all PM counters for this port are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.26.4.1.18
oscPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.27
oscNumEventsTotal number of all traps (events) generated by all OSC modules in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.27.1
oscPerfTableThis table represents the information for performance data collected for each OSC module.
SEQUENCE OF OscPerfEntry
.1.3.6.1.4.1.4253.2.1.27.2
oscPerfEntrySpecifies the index for each row in the table below
OscPerfEntry
.1.3.6.1.4.1.4253.2.1.27.2.1
oscPerfLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.27.2.1.1
oscPerfShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.27.2.1.2
oscPerfSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.27.2.1.3
oscPerfStateThe state of the OSC module. The states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.27.2.1.4
oscPerfStatusThe status of the OSC module. This status represents the status of the OSC module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.27.2.1.5
oscLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.27.2.1.6
oscAvailTimeThe number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.27.2.1.7
oscErrFreeSecsThe number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.27.2.1.8
oscCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF OscCntrEntry
.1.3.6.1.4.1.4253.2.1.27.3
oscCntrEntrySpecifies the index for each row in the table below
OscCntrEntry
.1.3.6.1.4.1.4253.2.1.27.3.1
oscCntrLocationThe location of the OSC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OSC cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.27.3.1.1
oscCntrShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OSC cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.27.3.1.2
oscCntrSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OSC cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.27.3.1.3
oscCntrTypeThe type of the software counter data in this row.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.27.3.1.4
oscTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.27.3.1.5
oscTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.27.3.1.6
oscTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.27.3.1.7
oscBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.27.3.1.8
oscBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.27.3.1.9
oscBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.27.3.1.10
oscMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.27.3.1.11
oscClearCntrsIf the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.27.3.1.12
oscPmTableThis table represents the information for each entry for the software counters.
SEQUENCE OF OscPmEntry
.1.3.6.1.4.1.4253.2.1.27.4
oscPmEntrySpecifies the index for each row in the table below
OscPmEntry
.1.3.6.1.4.1.4253.2.1.27.4.1
oscPmLocationThe location of the OSC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OSC cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.27.4.1.1
oscPmShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OSC cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.27.4.1.2
oscPmSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OSC cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.27.4.1.3
oscPmErrorsThe number of packets errors since port last came online.ro
Counter
.1.3.6.1.4.1.4253.2.1.27.4.1.4
oscPmErredSecsThe number of erred seconds since port last came online.ro
Counter
.1.3.6.1.4.1.4253.2.1.27.4.1.5
oscStartTimeThe date/time the port came last online.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.27.4.1.6
oscClearPmCntrsIf the value is reset, all PM counters for this port are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.27.4.1.7
ocm4gPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.28
ocm4gNumEventsTotal number of all traps (events) generated by all OCM4G modules in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.28.1
ocm4gPerfTableThis table represents the information for performance data collected for each OCM4G module.
SEQUENCE OF Ocm4gPerfEntry
.1.3.6.1.4.1.4253.2.1.28.2
ocm4gPerfEntrySpecifies the index for each row in the table below
Ocm4gPerfEntry
.1.3.6.1.4.1.4253.2.1.28.2.1
ocm4gPerfLocationThe location of the module. Choices are local or remote.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.28.2.1.1
ocm4gPerfShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.28.2.1.2
ocm4gPerfSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.28.2.1.3
ocm4gPerfStateThe state of the OCM4G module. The states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.28.2.1.4
ocm4gPerfStatusThe status of the OCM4G module. This status represents the status of the OCM4G module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.28.2.1.5
ocm4gLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.28.2.1.6
ocm4gAvailTimeThe number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.28.2.1.7
ocm4gErrFreeSecsThe number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.28.2.1.8
ocm4gCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF Ocm4gCntrEntry
.1.3.6.1.4.1.4253.2.1.28.3
ocm4gCntrEntrySpecifies the index for each row in the table below
Ocm4gCntrEntry
.1.3.6.1.4.1.4253.2.1.28.3.1
ocm4gCntrLocationThe location of the OCM4G card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM4G cards.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.28.3.1.1
ocm4gCntrShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM4G cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.28.3.1.2
ocm4gCntrSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM4G cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.28.3.1.3
ocm4gCntrTypeThe type of the software counter data in this row.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.28.3.1.4
ocm4gTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.28.3.1.5
ocm4gTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.28.3.1.6
ocm4gTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.28.3.1.7
ocm4gBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.28.3.1.8
ocm4gBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.28.3.1.9
ocm4gBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.28.3.1.10
ocm4gMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.1.28.3.1.11
ocm4gClearCntrsIf the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.28.3.1.12
ocm4gPmTableThis table represents the information for each entry for the software counters.
SEQUENCE OF Ocm4gPmEntry
.1.3.6.1.4.1.4253.2.1.28.4
ocm4gPmEntrySpecifies the index for each row in the table below
Ocm4gPmEntry
.1.3.6.1.4.1.4253.2.1.28.4.1
ocm4gPmLocationThe location of the OCM4G card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM4G cards.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.28.4.1.1
ocm4gPmShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM4G cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.28.4.1.2
ocm4gPmSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM4G cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.28.4.1.3
ocm4gPmLinkRxPwrLink receive power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.28.4.1.5
ocm4gPmLinkTxPwrLink transmit power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.28.4.1.6
ocm4gPmCpeRxPwrCPE receive power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.28.4.1.7
ocm4gPmCpeTxPwrCPE transmit power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.28.4.1.8
ocm4gPmNumLinkRxIntervalsThe of intervals (seconds) over which the link Rx statistics have been accumulated.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.28.4.1.9
ocm4gPmLinkRxErrorsLink receive errors.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.28.4.1.10
ocm4gPmLinkRxErredSecondsLink receive errored seconds.ro
Counter
.1.3.6.1.4.1.4253.2.1.28.4.1.11
ocm4gPmNumCpeRxIntervalsThe of intervals (seconds) over which the CPE Rx statistics have been accumulated.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.28.4.1.12
ocm4gPmCpeRxErrorsCPE receive errors.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.28.4.1.13
ocm4gPmCpeRxErredSecondsCPE receive errored seconds.ro
Counter
.1.3.6.1.4.1.4253.2.1.28.4.1.14
ocm4gPmNumCpeTxIntervalsThe of intervals (seconds) over which the CPE Tx statistics have been accumulated.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.28.4.1.15
ocm4gPmCpeTxErrorsCPE transmit errors.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.28.4.1.16
ocm4gPmCpeTxErredSecondsCPE transmit errored seconds.ro
Counter
.1.3.6.1.4.1.4253.2.1.28.4.1.17
ocm4gClearPmCntrsIf the value is reset, all PM counters for this port are reset to zero. A get on this will always return otherrw
ResetType
.1.3.6.1.4.1.4253.2.1.28.4.1.18
oetPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.29
oetNumEventsTotal number of all traps (events) generated by all OET modules in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.29.1
oetPerfTableThis table represents the information for performance data collected for each OET module.
SEQUENCE OF OetPerfEntry
.1.3.6.1.4.1.4253.2.1.29.2
oetPerfEntrySpecifies the index for each row in the table below
OetPerfEntry
.1.3.6.1.4.1.4253.2.1.29.2.1
oetPerfLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.29.2.1.1
oetPerfShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.29.2.1.2
oetPerfSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.29.2.1.3
oetPerfStateThe state of the OET module. The states are: online, offline, empty, loopback or diag.ro
CardState
.1.3.6.1.4.1.4253.2.1.29.2.1.4
oetPerfStatusThe status of the OET module. This status represents the status of the OET module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.29.2.1.5
oetLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.2.1.6
oetAvailTimeThe number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.29.2.1.7
oetErrFreeSecsThe number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.29.2.1.8
oetPmLinkTableThis table represents the information for each entry for the OET Link ports.
SEQUENCE OF OetPmLinkEntry
.1.3.6.1.4.1.4253.2.1.29.3
oetPmLinkEntrySpecifies the index for each row in the table below
OetPmLinkEntry
.1.3.6.1.4.1.4253.2.1.29.3.1
oetPmLinkLocationThe location of the OET card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OET cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.29.3.1.1
oetPmLinkShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OET cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.29.3.1.2
oetPmLinkSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OET cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.29.3.1.3
oetPmLinkNumIntervalsThe of intervals (seconds) over which the link statistics have been accumulated.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.29.3.1.5
oetPmLinkRxPwrLink receive power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.3.1.6
oetPmLinkRxBytesLink Rx Bytes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.3.1.7
oetPmLinkRxFcsErrsLink Rx FCS Errors.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.3.1.8
oetPmLinkTxPwrLink Tx power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.3.1.9
oetPmLinkTxTempPump temp in Cro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.3.1.10
oetPmLinkTxBytesLink Tx Bytes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.3.1.11
oetPmLinkFecTxFEC Link Tx.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.3.1.12
oetPmLinkFecCorrected1sFEC Corrected '1'sro
INTEGER
.1.3.6.1.4.1.4253.2.1.29.3.1.13
oetPmLinkFecCorrected0sFEC Corrected '0'sro
INTEGER
.1.3.6.1.4.1.4253.2.1.29.3.1.14
oetPmLinkFecCorrectedBitFEC Corrected Bitsro
INTEGER
.1.3.6.1.4.1.4253.2.1.29.3.1.15
oetPmLinkFecCorrectedByteFEC Corrected Bytesro
INTEGER
.1.3.6.1.4.1.4253.2.1.29.3.1.16
oetPmLinkFecUncorrectedByteFEC Uncorrected Bytesro
INTEGER
.1.3.6.1.4.1.4253.2.1.29.3.1.17
oetPmLinkFecBlockFEC Block Numberro
INTEGER
.1.3.6.1.4.1.4253.2.1.29.3.1.18
oetPmPortTableThis table represents the information for each entry for the OET CPE ports.
SEQUENCE OF OetPmPortEntry
.1.3.6.1.4.1.4253.2.1.29.4
oetPmPortEntrySpecifies the index for each row in the table below
OetPmPortEntry
.1.3.6.1.4.1.4253.2.1.29.4.1
oetPmPortLocationThe location of the OET card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OET cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.29.4.1.1
oetPmPortShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OET cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.29.4.1.2
oetPmPortSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OET cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.29.4.1.3
oetPmPortIndexPort for which the statistics are for.ro
Enumeration
.1.3.6.1.4.1.4253.2.1.29.4.1.4
oetPmPortNumIntervalsThe of intervals (seconds) over which the port statistics have been accumulated.ro
INTEGER
.1.3.6.1.4.1.4253.2.1.29.4.1.5
oetPmPortRxPwrPort receive power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.4.1.6
oetPmPortRxBytesPort Rx Bytes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.4.1.7
oetPmPortRxFcsErrsPort Rx FCS Errors.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.4.1.8
oetPmPortTxPwrLink Tx power.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.4.1.9
oetPmPortTxTempPump temp in Cro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.4.1.10
oetPmPortTxBytesPort Tx Bytes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.29.4.1.11
uobPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.30
uobNumEventsTotal number of all traps (events) generated by all UOB modules in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.30.1
uobPerfTableThis table represents the information for performance data collected for each UOB module.
SEQUENCE OF UobPerfEntry
.1.3.6.1.4.1.4253.2.1.30.2
uobPerfEntrySpecifies the index for each row in the table below
UobPerfEntry
.1.3.6.1.4.1.4253.2.1.30.2.1
uobPerfLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.30.2.1.1
uobPerfShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.30.2.1.2
uobPerfSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.30.2.1.3
uobPerfStateThe state of the UOB module. The states are: online = 2 and offline = 3ro
CardState
.1.3.6.1.4.1.4253.2.1.30.2.1.4
uobPerfStatusThis status represents the status of the UOB module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.30.2.1.5
uobLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.30.2.1.6
uobAvailTimeThe number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.30.2.1.7
uobErrFreeSecsThe number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.30.2.1.8
uobPmTableThis table represents the information for each entry for the software counters.
SEQUENCE OF UobPmEntry
.1.3.6.1.4.1.4253.2.1.30.3
uobPmEntrySpecifies the index for each row in the table below
UobPmEntry
.1.3.6.1.4.1.4253.2.1.30.3.1
uobPmLocationThe location of the UOB card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known UOB cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.30.3.1.1
uobPmShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) UOB cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.30.3.1.2
uobPmSlotThe slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) UOB cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.30.3.1.3
uobPmSystemStatusSystem Statusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.30.3.1.4
uobPmPumpCurrentPump Current in mAro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.30.3.1.5
uobPmPumpTempPump temp in Cro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.30.3.1.6
uobPmInputPowerInput pwr in dBmro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.30.3.1.7
uobPmOutPowerOutput pwr in dBmro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.30.3.1.8
uobPmTotalGainTotal gain in dBro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.30.3.1.9
uobPmReflectionReflection in dBro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.30.3.1.10
fc8gPerf
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.1.31
fc8gNumEventsTotal number of all traps (events) generated by all FC8G modules in this time slot (15 minutes).ro
Counter
.1.3.6.1.4.1.4253.2.1.31.1
fc8gPerfTableThis table represents the information for performance data collected for each FC8G module.
SEQUENCE OF Fc8gPerfEntry
.1.3.6.1.4.1.4253.2.1.31.2
fc8gPerfEntrySpecifies the index for each row in the table below
Fc8gPerfEntry
.1.3.6.1.4.1.4253.2.1.31.2.1
fc8gPerfLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.1.31.2.1.1
fc8gPerfShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.1.31.2.1.2
fc8gPerfSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.1.31.2.1.3
fc8gPerfStateThe state of the FC8G module. The states are: online, offline, empty or loopback.ro
CardState
.1.3.6.1.4.1.4253.2.1.31.2.1.4
fc8gPerfStatusThe status of the FC8G module. This status represents the status of the FC8G module and in general is different from the status of the system.ro
CardStatus
.1.3.6.1.4.1.4253.2.1.31.2.1.5
fc8gLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.1.31.2.1.6
fc8gAvailTimeThe number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).ro
Counter
.1.3.6.1.4.1.4253.2.1.31.2.1.7
fc8gErrFreeSecsThe number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.1.31.2.1.8
historical
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2
systemHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.1
sysHistTableThis table represents the information for historical data collected for the overall system
SEQUENCE OF SysHistEntry
.1.3.6.1.4.1.4253.2.2.1.1
sysHistEntrySpecifies the index for each row in the table below
SysHistEntry
.1.3.6.1.4.1.4253.2.2.1.1.1
sysHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.1.1.1.1
sysHLastBootTimeThe date and time of the last system boot. This time represents the boot time of a CP card. It is also anonymous with the power-up cycle of the chassis.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.1.1.1.2
sysHAvailTimeThe number of seconds since the system has been up and running. The criteria for the system available time is having at least one CP running with atmost non-service affecting minor alarm system statusro
Counter
.1.3.6.1.4.1.4253.2.2.1.1.1.3
sysHErrFreeSecsThe number of seconds that the device has not experienced any alarms. This counter is across all cards in the chassis. The system must be in Normal status for this counter to be incremented.ro
Counter
.1.3.6.1.4.1.4253.2.2.1.1.1.4
downloadHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.2
dlHistTableThis table represents the information for historical data collected for the download process
SEQUENCE OF DlHistEntry
.1.3.6.1.4.1.4253.2.2.2.1
dlHistEntrySpecifies the index for each row in the table below
DlHistEntry
.1.3.6.1.4.1.4253.2.2.2.1.1
dlHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.2.1.1.1
dlHOkDownloadsThe number of successful downloadsro
Counter
.1.3.6.1.4.1.4253.2.2.2.1.1.2
dlHBadDownloadsThe number of failed downloadsro
Counter
.1.3.6.1.4.1.4253.2.2.2.1.1.3
dlHLongestTimeLongest time for any download, in secondsro
Gauge
.1.3.6.1.4.1.4253.2.2.2.1.1.4
dlHLongestSizeLongest download size for any download, in bytesro
Gauge
.1.3.6.1.4.1.4253.2.2.2.1.1.5
cpHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.3
cpHistTableThis table represents the information for historical data collected for the communication card
SEQUENCE OF CpHistEntry
.1.3.6.1.4.1.4253.2.2.3.1
cpHistEntrySpecifies the index for each row in the table below
CpHistEntry
.1.3.6.1.4.1.4253.2.2.3.1.1
cpHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.3.1.1.1
cpHNumEventsTotal number of events received by the active CPro
Counter
.1.3.6.1.4.1.4253.2.2.3.1.1.2
cpHTrapsSentTotal number of traps sent by the active CPro
Counter
.1.3.6.1.4.1.4253.2.2.3.1.1.3
cpHSNMPCmdsRcvdTotal number of SNMP commands received by the active CP.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.1.1.4
cpHCntrTableThis table represents the information for each entry for the software counters. It is only applicable to the active MPM card.
SEQUENCE OF CpHCntrEntry
.1.3.6.1.4.1.4253.2.2.3.2
cpHCntrEntrySpecifies the index for each row in the table below
CpHCntrEntry
.1.3.6.1.4.1.4253.2.2.3.2.1
cpHCntrModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.3.2.1.1
cpHCntrShelfThe shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the value of the current active CP card.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.3.2.1.2
cpHCntrSlotThe slot within the shelf the card is in. The system automatically determines the right value for this entry based on the value of the current active CP card.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.3.2.1.3
cpHCntrTypeThe type of the software counter data in this row. The data is collected for the SPI data channels.ro
Enumeration
.1.3.6.1.4.1.4253.2.2.3.2.1.4
cpHTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.2.1.5
cpHTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.2.1.6
cpHBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.2.1.7
cpHTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.2.1.8
cpHBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.2.1.9
cpHBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.2.1.10
cpHMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.2.1.11
cpHBufAllocFailNumber of buffer allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.2.1.12
cpHEcbAllocFailNumber of Event Control Block allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.2.1.13
cpHHistTableThis table represents the information for performance data collected for each communication processor
SEQUENCE OF CpHHistEntry
.1.3.6.1.4.1.4253.2.2.3.3
cpHHistEntrySpecifies the index for each row in the table below
CpHHistEntry
.1.3.6.1.4.1.4253.2.2.3.3.1
cpHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.3.3.1.1
cpHHistShelfThe shelf the card is in. Valid values are: 1 to 10ro
CardShelf
.1.3.6.1.4.1.4253.2.2.3.3.1.2
cpHHistSlotThe slot within the shelf the card is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.3.3.1.3
cpHLastBootTimeThe date and time of the last boot for this CP.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.3.3.1.4
cpHAvailTimeThe number of seconds that this CP has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.3.1.5
cpHErrFreeSecsThe number of seconds that this CP has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.3.3.1.6
ccHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.4
ccHistTableThis table represents the information for historical data collected for the channel card
SEQUENCE OF CcHistEntry
.1.3.6.1.4.1.4253.2.2.4.1
ccHistEntrySpecifies the index for each row in the table below
CcHistEntry
.1.3.6.1.4.1.4253.2.2.4.1.1
ccHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.4.1.1.1
ccHNumEventsTotal number of events received for all CC'sro
Counter
.1.3.6.1.4.1.4253.2.2.4.1.1.2
ccHCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF CcHCntrEntry
.1.3.6.1.4.1.4253.2.2.4.2
ccHCntrEntrySpecifies the index for each row in the table below
CcHCntrEntry
.1.3.6.1.4.1.4253.2.2.4.2.1
ccHCntrModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.4.2.1.1
ccHCntrLocationThe location of the CC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known CC cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.4.2.1.2
ccHCntrShelfThe shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the known (available) CC cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.4.2.1.3
ccHCntrSlotThe slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) CC cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.4.2.1.4
ccHCntrTypeThe type of the software counter data in this row. The data is collected for the SPI data channels.ro
Enumeration
.1.3.6.1.4.1.4253.2.2.4.2.1.5
ccHTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.4.2.1.6
ccHTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.4.2.1.7
ccHBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.4.2.1.8
ccHTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.4.2.1.9
ccHBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.4.2.1.10
ccHBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.4.2.1.11
ccHMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.4.2.1.12
ccHBufAllocFailNumber of buffer allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.4.2.1.13
ccHEcbAllocFailNumber of Event Control Block allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.4.2.1.14
ccHHistTableThis table represents the information for performance data collected for each channel card
SEQUENCE OF CcHHistEntry
.1.3.6.1.4.1.4253.2.2.4.3
ccHHistEntrySpecifies the index for each row in the table below
CcHHistEntry
.1.3.6.1.4.1.4253.2.2.4.3.1
ccHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.4.3.1.1
ccHHistLocationThe location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.4.3.1.2
ccHHistShelfThe shelf the card is in. Valid values are: 1 to 10ro
CardShelf
.1.3.6.1.4.1.4253.2.2.4.3.1.3
ccHHistSlotThe slot within the shelf the card is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.4.3.1.4
ccHLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.4.3.1.5
ccHAvailTimeThe number of seconds that this CC has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.4.3.1.6
ccHErrFreeSecsThe number of seconds that this CC has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.4.3.1.7
muxHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.5
muxHistTableThis table represents the information for historical data collected for the mux/demux card
SEQUENCE OF MuxHistEntry
.1.3.6.1.4.1.4253.2.2.5.1
muxHistEntrySpecifies the index for each row in the table below
MuxHistEntry
.1.3.6.1.4.1.4253.2.2.5.1.1
muxHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.5.1.1.1
muxHNumEventsTotal number of all traps (events) generated by all MUX's.ro
Counter
.1.3.6.1.4.1.4253.2.2.5.1.1.2
muxHHistTableThis table represents the information for performance data collected for each mux/demux card
SEQUENCE OF MuxHHistEntry
.1.3.6.1.4.1.4253.2.2.5.2
muxHHistEntrySpecifies the index for each row in the table below
MuxHHistEntry
.1.3.6.1.4.1.4253.2.2.5.2.1
muxHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.5.2.1.1
muxHHistLocationThe location of the card. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.5.2.1.2
muxHHistShelfThe shelf the card is in. Valid values are: 1 to 10ro
CardShelf
.1.3.6.1.4.1.4253.2.2.5.2.1.3
muxHHistSlotThe slot within the shelf the card is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.5.2.1.4
muxHHistTypeThe type of the mux. The choices are: mux or demux.ro
Enumeration
.1.3.6.1.4.1.4253.2.2.5.2.1.5
muxHLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.5.2.1.6
muxHAvailTimeThe number of seconds that this Mux has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.5.2.1.7
muxHErrFreeSecsThe number of seconds that this mux has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.5.2.1.8
psHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.6
psHistTableThis table represents the information for historical data collected for the power supply card
SEQUENCE OF PsHistEntry
.1.3.6.1.4.1.4253.2.2.6.1
psHistEntrySpecifies the index for each row in the table below
PsHistEntry
.1.3.6.1.4.1.4253.2.2.6.1.1
psHModeThe mode of the data collection. Valid values are: daily or longterm.
HistoryMode
.1.3.6.1.4.1.4253.2.2.6.1.1.1
psHNumEventsTotal number of all traps (events) generated by all Power Supplies.
Counter
.1.3.6.1.4.1.4253.2.2.6.1.1.2
fadmHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.7
fadmHistTableThis table represents the information for historical data collected for the fadm card
SEQUENCE OF FadmHistEntry
.1.3.6.1.4.1.4253.2.2.7.1
fadmHistEntrySpecifies the index for each row in the table below
FadmHistEntry
.1.3.6.1.4.1.4253.2.2.7.1.1
fadmHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.7.1.1.1
fadmHNumEventsTotal number of all traps (events) generated by all FADM's.ro
Counter
.1.3.6.1.4.1.4253.2.2.7.1.1.2
fadmHHistTableThis table represents the information for performance data collected for each fadm card
SEQUENCE OF FadmHHistEntry
.1.3.6.1.4.1.4253.2.2.7.2
fadmHHistEntrySpecifies the index for each row in the table below
FadmHHistEntry
.1.3.6.1.4.1.4253.2.2.7.2.1
fadmHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.7.2.1.1
fadmHHistLocationThe location of the card. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.7.2.1.2
fadmHHistShelfThe shelf the card is in. Valid values are: 1 to 10ro
CardShelf
.1.3.6.1.4.1.4253.2.2.7.2.1.3
fadmHHistSlotThe slot within the shelf the card is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.7.2.1.4
fadmHLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.7.2.1.6
fadmHAvailTimeThe number of seconds that this Mux has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.7.2.1.7
fadmHErrFreeSecsThe number of seconds that this mux has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.7.2.1.8
oppmHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.8
oppmHistTableThis table represents the information for historical data collected for the oppm card
SEQUENCE OF OppmHistEntry
.1.3.6.1.4.1.4253.2.2.8.1
oppmHistEntrySpecifies the index for each row in the table below
OppmHistEntry
.1.3.6.1.4.1.4253.2.2.8.1.1
oppmHModeThe mode of the data collection. Valid values are: daily or longterm.
HistoryMode
.1.3.6.1.4.1.4253.2.2.8.1.1.1
oppmHNumEventsTotal number of all traps (events) generated by all OPPM's.
Counter
.1.3.6.1.4.1.4253.2.2.8.1.1.2
oppmHHistTableThis table represents the information for performance data collected for each fadm card
SEQUENCE OF OppmHHistEntry
.1.3.6.1.4.1.4253.2.2.8.2
oppmHHistEntrySpecifies the index for each row in the table below
OppmHHistEntry
.1.3.6.1.4.1.4253.2.2.8.2.1
oppmHHistModeThe mode of the data collection. Valid values are: daily or longterm.
HistoryMode
.1.3.6.1.4.1.4253.2.2.8.2.1.1
oppmHHistLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.2.8.2.1.2
oppmHHistShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.2.8.2.1.3
oppmHHistSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.2.8.2.1.4
oppmHLastBootTimeThe date and time of the last boot for this card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.8.2.1.6
oppmHAvailTimeThe number of seconds that this Mux has been up and running.
Counter
.1.3.6.1.4.1.4253.2.2.8.2.1.7
oppmHErrFreeSecsThe number of seconds that this mux has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.2.8.2.1.8
mcmHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.9
mcmHistTableThis table represents the information for historical data collected for the channel card
SEQUENCE OF McmHistEntry
.1.3.6.1.4.1.4253.2.2.9.1
mcmHistEntrySpecifies the index for each row in the table below
McmHistEntry
.1.3.6.1.4.1.4253.2.2.9.1.1
mcmHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.9.1.1.1
mcmHNumEventsTotal number of events received for all mcmt1's/mcme1'sro
Counter
.1.3.6.1.4.1.4253.2.2.9.1.1.2
mcmHCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF McmHCntrEntry
.1.3.6.1.4.1.4253.2.2.9.2
mcmHCntrEntrySpecifies the index for each row in the table below
McmHCntrEntry
.1.3.6.1.4.1.4253.2.2.9.2.1
mcmHCntrModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.9.2.1.1
mcmHCntrLocationThe location of the mcm/mcme1 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmt1/mcme1 cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.9.2.1.2
mcmHCntrShelfThe shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.9.2.1.3
mcmHCntrSlotThe slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.9.2.1.4
mcmHCntrTypeThe type of the software counter data in this row. The data is collected for the SPI data channels.ro
Enumeration
.1.3.6.1.4.1.4253.2.2.9.2.1.5
mcmHTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.2.1.6
mcmHTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.2.1.7
mcmHBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.2.1.8
mcmHTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.2.1.9
mcmHBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.2.1.10
mcmHBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.2.1.11
mcmHMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.2.1.12
mcmHBufAllocFailNumber of buffer allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.2.1.13
mcmHEcbAllocFailNumber of Event Control Block allocation failures for the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.2.1.14
mcmPortHIntervalTableThis table represents the information for each entry for the mcmt1/mcme1 port counters.
SEQUENCE OF McmPortHIntervalEntry
.1.3.6.1.4.1.4253.2.2.9.3
mcmPortHIntervalEntrySpecifies the index for each row in the table below
McmPortHIntervalEntry
.1.3.6.1.4.1.4253.2.2.9.3.1
mcmPortHIntervalLocationThe location of the mcm/mcme1 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcm/mcme1 cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.9.3.1.1
mcmPortHIntervalShelfThe shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.9.3.1.2
mcmPortHIntervalSlotThe slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.9.3.1.3
mcmPortHIntervalPortThe port within the shelf the card is in. Valid values are: 1 to 4. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.9.3.1.4
mcmPortHIntervalNumberThe Interval number of the ds1 port. Valid values are: 1 to 96. The system automatically determines the right value for this entry based on the known (available) interval number.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.9.3.1.5
mcmPortHIntervalASsMCMT1/MCME1 port's ASs counter for specific interval.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.3.1.6
mcmPortHIntervalFrameASsMCMT1/MCME1 port's FrameASs counter for specific interval.
Counter
.1.3.6.1.4.1.4253.2.2.9.3.1.7
mcmPortHIntervalFEsMCMT1/MCME1 port's FEs counter for specific interval.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.3.1.8
mcmPortHIntervalCRCErrsMCMT1/MCME1 port's CRC errs counter for specific interval.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.3.1.9
mcmPortHIntervalSESsMCMT1/MCME1 port's SESs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.3.1.10
mcmPortHIntervalSEFSsMCMT1/MCME1 port's SEFSs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.3.1.11
mcmPortHIntervalUASsMCMT1/MCME1 port's UASs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.3.1.12
mcmPortHIntervalLESsMCMT1/MCME1 port's LESs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.3.1.13
mcmPortHIntervalBESsMCMT1/MCME1 port's BESs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.3.1.14
mcmPortHIntervalDMsMCMT1/MCME1 port's DMSs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.3.1.15
mcmPortHIntervalLCVsMCMT1/MCME1 port's LCVs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.3.1.16
mcmPortHTotalTableThis table represents the information for each entry for the mcmt1/mcme1 port counters.
SEQUENCE OF McmPortHTotalEntry
.1.3.6.1.4.1.4253.2.2.9.4
mcmPortHTotalEntrySpecifies the index for each row in the table below
McmPortHTotalEntry
.1.3.6.1.4.1.4253.2.2.9.4.1
mcmPortHTotalLocationThe location of the mcm card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcm/mcme1 cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.9.4.1.1
mcmPortHTotalShelfThe shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.9.4.1.2
mcmPortHTotalSlotThe slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.9.4.1.3
mcmPortHTotalPortThe port within the shelf the card is in. Valid values are: 1 to 4. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.9.4.1.4
mcmPortHTotalASsMCMT1/MCME1 port's ASs counter for the last 24 hrs.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.4.1.5
mcmPortHTotalFrameASsMCMT1/MCME1 port's FrameASs counter for the last 24 hrs.
Counter
.1.3.6.1.4.1.4253.2.2.9.4.1.6
mcmPortHTotalFEsMCMT1/MCME1 port's FEs counter for the last 24 hrs.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.4.1.7
mcmPortHTotalCRCErrsMCMT1/MCME1 port's CRC errs counter for the last 24 hrs.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.4.1.8
mcmPortHTotalSESsMCMT1/MCME1 port's SESs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.4.1.9
mcmPortHTotalSEFSsMCMT1/MCME1 port's SEFSs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.4.1.10
mcmPortHTotalUASsMCMT1/MCME1 port's UASs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.4.1.11
mcmPortHTotalLESsMCMT1/MCME1 port's LESs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.4.1.12
mcmPortHTotalBESsMCMT1/MCME1 port's BESs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.4.1.13
mcmPortHTotalDMsMCMT1/MCME1 port's DMSs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.4.1.14
mcmPortHTotalLCVsMCMT1/MCME1 port's LCVs counter less than 15 mins.ro
Counter
.1.3.6.1.4.1.4253.2.2.9.4.1.15
fnHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.10
fnHistTableThis table represents the information for historical data collected for the fan modules
SEQUENCE OF FnHistEntry
.1.3.6.1.4.1.4253.2.2.10.1
fnHistEntrySpecifies the index for each row in the table below
FnHistEntry
.1.3.6.1.4.1.4253.2.2.10.1.1
fnHModeThe mode of the data collection. Valid values are: daily or longterm.
HistoryMode
.1.3.6.1.4.1.4253.2.2.10.1.1.1
fnHNumEventsTotal number of all traps (events) generated by all fan modules.
Counter
.1.3.6.1.4.1.4253.2.2.10.1.1.2
csimHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.11
csimHistTableThis table represents the information for historical data collected for the ColorSIM
SEQUENCE OF CsimHistEntry
.1.3.6.1.4.1.4253.2.2.11.1
csimHistEntrySpecifies the index for each row in the table below
CsimHistEntry
.1.3.6.1.4.1.4253.2.2.11.1.1
csimHModeThe mode of the data collection. Valid values are: daily or longterm. The reason this has been made obsolete is that all colorsim related events would eventually be part of ocm events
HistoryMode
.1.3.6.1.4.1.4253.2.2.11.1.1.1
csimHNumEventsThis variable keeps track of the number of events related to ColorSIM. The reason this has been made obsolete is that all colorsim related events would eventually be part of ocm events
Counter
.1.3.6.1.4.1.4253.2.2.11.1.1.2
csimHistIntervalTableThis table represents the information for each colorsim card.
SEQUENCE OF CsimHistIntervalEntry
.1.3.6.1.4.1.4253.2.2.11.2
csimHistIntervalEntrySpecifies the index for each row in the table below
CsimHistIntervalEntry
.1.3.6.1.4.1.4253.2.2.11.2.1
csimIntervalLocationLocation of the ColorSIM modulero
CardLocation
.1.3.6.1.4.1.4253.2.2.11.2.1.1
csimIntervalShelfThe shelf of the ColorSIM modulero
CardShelf
.1.3.6.1.4.1.4253.2.2.11.2.1.2
csimIntervalSlotThe Slot of the ColorSIM modulero
CardSlot
.1.3.6.1.4.1.4253.2.2.11.2.1.3
csimIntervalNumberThis variable indicates the interval for which the set of statistics data is available.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.11.2.1.4
csimIntervalEFIsThe counter associated with the number of Error Free Interval Counts in this interval.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.11.2.1.5
csimIntervalEIsThe counter associated with the number of Errored Interval Counts in this interval.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.11.2.1.6
csimIntervalSEIsThe counter associated with the number of Severely Errored Interval Counts in this interval.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.11.2.1.7
csimIntervalBERsThe counter associated with the number of Bit Error Rate Counts in this interval. The unit is in the form of x.ye-z.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.11.2.1.8
csimIntervalUAIsThe counter associated with the number of Unavailable Interval Counts in this interval.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.11.2.1.9
csimIntervalValidDataThis variable indicates if the data for this interval is valid. Not supported
Boolean
.1.3.6.1.4.1.4253.2.2.11.2.1.10
csimIntervalDateTimeTime in seconds elasped since 01/01/1970 00:00:00 GMT for this interval. Assuming local time is same as GMTro
INTEGER
.1.3.6.1.4.1.4253.2.2.11.2.1.11
rpsmHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.12
rpsmHistTableThis table represents the information for historical data collected for the rpsm card
SEQUENCE OF RpsmHistEntry
.1.3.6.1.4.1.4253.2.2.12.1
rpsmHistEntrySpecifies the index for each row in the table below
RpsmHistEntry
.1.3.6.1.4.1.4253.2.2.12.1.1
rpsmHModeThe mode of the data collection. Valid values are: daily or longterm.
HistoryMode
.1.3.6.1.4.1.4253.2.2.12.1.1.1
rpsmHNumEventsTotal number of all traps (events) generated by all RPSM's.
Counter
.1.3.6.1.4.1.4253.2.2.12.1.1.2
rpsmHHistTableThis table represents the information for performance data collected for each rpsm card
SEQUENCE OF RpsmHHistEntry
.1.3.6.1.4.1.4253.2.2.12.2
rpsmHHistEntrySpecifies the index for each row in the table below
RpsmHHistEntry
.1.3.6.1.4.1.4253.2.2.12.2.1
rpsmHHistModeThe mode of the data collection. Valid values are: daily or longterm.
HistoryMode
.1.3.6.1.4.1.4253.2.2.12.2.1.1
rpsmHHistLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.2.12.2.1.2
rpsmHHistShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.2.12.2.1.3
rpsmHHistSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.2.12.2.1.4
rpsmHLastBootTimeThe date and time of the last boot for this card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.12.2.1.6
rpsmHAvailTimeThe number of seconds that this rpsm has been up and running.
Counter
.1.3.6.1.4.1.4253.2.2.12.2.1.7
rpsmHErrFreeSecsThe number of seconds that this rpsm has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.2.12.2.1.8
rsdmHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.13
rsdmHistTableThis table represents the information for historical data collected for the rsdm card
SEQUENCE OF RsdmHistEntry
.1.3.6.1.4.1.4253.2.2.13.1
rsdmHistEntrySpecifies the index for each row in the table below
RsdmHistEntry
.1.3.6.1.4.1.4253.2.2.13.1.1
rsdmHModeThe mode of the data collection. Valid values are: daily or longterm.
HistoryMode
.1.3.6.1.4.1.4253.2.2.13.1.1.1
rsdmHNumEventsTotal number of all traps (events) generated by all RSDM's.
Counter
.1.3.6.1.4.1.4253.2.2.13.1.1.2
rsdmHHistTableThis table represents the information for performance data collected for each rsdm card.
SEQUENCE OF RsdmHHistEntry
.1.3.6.1.4.1.4253.2.2.13.2
rsdmHHistEntrySpecifies the index for each row in the table below
RsdmHHistEntry
.1.3.6.1.4.1.4253.2.2.13.2.1
rsdmHHistModeThe mode of the data collection. Valid values are: daily or longterm.
HistoryMode
.1.3.6.1.4.1.4253.2.2.13.2.1.1
rsdmHHistLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.2.13.2.1.2
rsdmHHistShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.2.13.2.1.3
rsdmHHistSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.2.13.2.1.4
rsdmHLastBootTimeThe date and time of the last boot for this card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.13.2.1.6
rsdmHAvailTimeThe number of seconds that this rsdm has been up and running.
Counter
.1.3.6.1.4.1.4253.2.2.13.2.1.7
rsdmHErrFreeSecsThe number of seconds that this rsdm has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.2.13.2.1.8
rtdmHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.14
rtdmHistTableThis table represents the information for historical data collected for the rtdm card
SEQUENCE OF RtdmHistEntry
.1.3.6.1.4.1.4253.2.2.14.1
rtdmHistEntrySpecifies the index for each row in the table below
RtdmHistEntry
.1.3.6.1.4.1.4253.2.2.14.1.1
rtdmHModeThe mode of the data collection. Valid values are: daily or longterm.
HistoryMode
.1.3.6.1.4.1.4253.2.2.14.1.1.1
rtdmHNumEventsTotal number of all traps (events) generated by all rtdm's.
Counter
.1.3.6.1.4.1.4253.2.2.14.1.1.2
rtdmHHistTableThis table represents the information for performance data collected for each rtdm card.
SEQUENCE OF RtdmHHistEntry
.1.3.6.1.4.1.4253.2.2.14.2
rtdmHHistEntrySpecifies the index for each row in the table below
RtdmHHistEntry
.1.3.6.1.4.1.4253.2.2.14.2.1
rtdmHHistModeThe mode of the data collection. Valid values are: daily or longterm.
HistoryMode
.1.3.6.1.4.1.4253.2.2.14.2.1.1
rtdmHHistLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.2.14.2.1.2
rtdmHHistShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.2.14.2.1.3
rtdmHHistSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.2.14.2.1.4
rtdmHLastBootTimeThe date and time of the last boot for this card.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.14.2.1.5
rtdmHAvailTimeThe number of seconds that this rtdm has been up and running.
Counter
.1.3.6.1.4.1.4253.2.2.14.2.1.6
rtdmHErrFreeSecsThe number of seconds that this rtdm has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.2.14.2.1.7
osamHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.15
osamHistTableThis table represents the information for historical data collected for the osam module.
SEQUENCE OF OsamHistEntry
.1.3.6.1.4.1.4253.2.2.15.1
osamHistEntrySpecifies the index for each row in the table below
OsamHistEntry
.1.3.6.1.4.1.4253.2.2.15.1.1
osamHModeThe mode of data collection.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.15.1.1.1
osamHNumEventsTotal number of events received for all osam's.ro
Counter
.1.3.6.1.4.1.4253.2.2.15.1.1.2
osamHHistTableThis table represents the information for historical performance data collected for each osam module.
SEQUENCE OF OsamHHistEntry
.1.3.6.1.4.1.4253.2.2.15.2
osamHHistEntrySpecifies the index for each row in the table below
OsamHHistEntry
.1.3.6.1.4.1.4253.2.2.15.2.1
osamHHistModeThe mode of the data collection.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.15.2.1.1
osamHHistLocationLocation of the module.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.15.2.1.2
osamHHistShelfThe shelf number in which the module is plugged in.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.15.2.1.3
osamHHistSlotThe slot number in which the module is plugged in.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.15.2.1.4
osamHHistLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.15.2.1.5
osamHHistAvailTimeThe number of seconds since the start of this historical mode that this module has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.15.2.1.6
osamHHistErrFreeSecsThe number of seconds since the start of this historical mode that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.15.2.1.7
rsmHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.16
rsmHistTableThis table represents the information for historical data collected for the rsm card
SEQUENCE OF RsmHistEntry
.1.3.6.1.4.1.4253.2.2.16.1
rsmHistEntrySpecifies the index for each row in the table below
RsmHistEntry
.1.3.6.1.4.1.4253.2.2.16.1.1
rsmHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.16.1.1.1
rsmHNumEventsTotal number of all traps (events) generated by all RSM's.ro
Counter
.1.3.6.1.4.1.4253.2.2.16.1.1.2
rsmHHistTableThis table represents the information for performance data collected for each rsm card.
SEQUENCE OF RsmHHistEntry
.1.3.6.1.4.1.4253.2.2.16.2
rsmHHistEntrySpecifies the index for each row in the table below
RsmHHistEntry
.1.3.6.1.4.1.4253.2.2.16.2.1
rsmHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.16.2.1.1
rsmHHistLocationThe location of the card.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.16.2.1.2
rsmHHistShelfThe shelf the card is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.16.2.1.3
rsmHHistSlotThe slot within the shelf the card is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.16.2.1.4
rsmHLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.16.2.1.6
rsmHAvailTimeThe number of seconds that this rsm has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.16.2.1.7
rsmHErrFreeSecsThe number of seconds that this rsm has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.16.2.1.8
upsmHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.17
upsmHistTableThis table represents the information for historical data collected for the upsm card
SEQUENCE OF UpsmHistEntry
.1.3.6.1.4.1.4253.2.2.17.1
upsmHistEntrySpecifies the index for each row in the table below
UpsmHistEntry
.1.3.6.1.4.1.4253.2.2.17.1.1
upsmHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.17.1.1.1
upsmHNumEventsTotal number of all traps (events) generated by all UPSM's.ro
Counter
.1.3.6.1.4.1.4253.2.2.17.1.1.2
upsmHHistTableThis table represents the information for performance data collected for each upsm card.
SEQUENCE OF UpsmHHistEntry
.1.3.6.1.4.1.4253.2.2.17.2
upsmHHistEntrySpecifies the index for each row in the table below
UpsmHHistEntry
.1.3.6.1.4.1.4253.2.2.17.2.1
upsmHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.17.2.1.1
upsmHHistLocationThe location of the card.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.17.2.1.2
upsmHHistShelfThe shelf the card is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.17.2.1.3
upsmHHistSlotThe slot within the shelf the card is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.17.2.1.4
upsmHLastBootTimeThe date and time of the last boot for this card.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.17.2.1.6
upsmHAvailTimeThe number of seconds that this upsm has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.17.2.1.7
upsmHErrFreeSecsThe number of seconds that this upsm has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.17.2.1.8
mcmescHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.18
mcmescHistTableThis table represents the information for historical data collected for the channel card
SEQUENCE OF McmescHistEntry
.1.3.6.1.4.1.4253.2.2.18.1
mcmescHistEntrySpecifies the index for each row in the table below
McmescHistEntry
.1.3.6.1.4.1.4253.2.2.18.1.1
mcmescHModeThe mode of the data collection. Valid values are: daily or long term.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.18.1.1.1
mcmescHNumEventsTotal number of events received for all mcmesc'sro
Counter
.1.3.6.1.4.1.4253.2.2.18.1.1.2
mcmescHCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF McmescHCntrEntry
.1.3.6.1.4.1.4253.2.2.18.2
mcmescHCntrEntrySpecifies the index for each row in the table below
McmescHCntrEntry
.1.3.6.1.4.1.4253.2.2.18.2.1
mcmescHCntrModeThe mode of the data collection. Valid values are: daily or long term.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.18.2.1.1
mcmescHCntrLocationThe location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.18.2.1.2
mcmescHCntrShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.18.2.1.3
mcmescHCntrSlotThe slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.18.2.1.4
mcmescHCntrTypeThe type of the software counter data in this row. The data is collected for the SPI data channels.ro
Enumeration
.1.3.6.1.4.1.4253.2.2.18.2.1.5
mcmescHTotPktSentThe number of data packets sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.2.1.6
mcmescHTotPktRcvdThe number of data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.2.1.7
mcmescHBadPktRcvdThe number of bad data packets received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.2.1.8
mcmescHTotBadTransThe number of bad data transmissions over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.2.1.9
mcmescHBytesSentTotal number of bytes sent over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.2.1.10
mcmescHBytesRcvdTotal number of data bytes received over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.2.1.11
mcmescHMsgsDlvrdThe number of complete messages delivered over the given data channel.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.2.1.12
mcmescPortHIntervalTableThis table represents the information for each entry for the mcmesc port counters.
SEQUENCE OF McmescPortHIntervalEntry
.1.3.6.1.4.1.4253.2.2.18.3
mcmescPortHIntervalEntrySpecifies the index for each row in the table below
McmescPortHIntervalEntry
.1.3.6.1.4.1.4253.2.2.18.3.1
mcmescPortHIntervalLocationThe location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.18.3.1.1
mcmescPortHIntervalShelfThe shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.18.3.1.2
mcmescPortHIntervalSlotThe slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.18.3.1.3
mcmescPortHIntervalPortThe CPE port within the shelf the card is in. Valid values are: 1 to 12. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.18.3.1.4
mcmescPortHIntervalNumberThe interval number. Valid values are: 1 to 96, where 1 indicates the most recently completed interval.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.18.3.1.5
mcmescPortHIntervalDurationMCMESC CPE port's duration, in seconds, for specific interval. The * indicates an incomplete interval resulted from interval setting change.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.3.1.6
mcmescPortHIntervalEnsMCMESC CPE port's enabled seconds for specific interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.3.1.7
mcmescPortHIntervalLossMCMESC CPE port's loss of signal seconds for specific interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.3.1.8
mcmescPortHIntervalCrcErrMCMESC CPE port's CRC errs counter for specific interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.3.1.9
mcmescPortHIntervalOobErrMCMESC CPE port's Out-of-band error counter for specific interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.3.1.10
mcmescPortHIntervalRdpErrMCMESC CPE port's Running Disparity error counter for specific interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.3.1.11
mcmescLinkHIntervalTableThis table represents the information for each entry for the mcmesc port counters.
SEQUENCE OF McmescLinkHIntervalEntry
.1.3.6.1.4.1.4253.2.2.18.4
mcmescLinkHIntervalEntrySpecifies the index for each row in the table below
McmescLinkHIntervalEntry
.1.3.6.1.4.1.4253.2.2.18.4.1
mcmescLinkHIntervalLocationThe location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.18.4.1.1
mcmescLinkHIntervalShelfThe shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.18.4.1.2
mcmescLinkHIntervalSlotThe slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.18.4.1.3
mcmescLinkHIntervalNumberThe interval number. Valid values are: 1 to 96, where 1 indicates the most recently completed interval.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.18.4.1.4
mcmescLinkHIntervalDurationMCMESC link port's duration, in seconds, for specific interval. The * indicates an incomplete interval resulted from interval setting change.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.4.1.5
mcmescLinkHIntervalTsosMCMESC link port's test-sequence on seconds for specific interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.4.1.6
mcmescLinkHIntervalLossMCMESC link port's loss of signal seconds for specific interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.4.1.7
mcmescLinkHIntervalCrcErrMCMESC link port's CRC errs counter for specific interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.4.1.8
mcmescLinkHIntervalOobErrMCMESC link port's Out-of-band error counter for specific interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.4.1.9
mcmescLinkHIntervalRdpErrMCMESC link port's Running Disparity error counter for specific interval.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.4.1.10
mcmescPortHTotalTableThis table represents the information for each mcmesc cpe port's total counters of up to 96 intervals.
SEQUENCE OF McmescPortHTotalEntry
.1.3.6.1.4.1.4253.2.2.18.5
mcmescPortHTotalEntrySpecifies the index for each row in the table below
McmescPortHTotalEntry
.1.3.6.1.4.1.4253.2.2.18.5.1
mcmescPortHTotalCardLocationLocation of the MCMESC CPE port. Valid values are: Local in the same chassis, or remote to this chassisro
CardLocation
.1.3.6.1.4.1.4253.2.2.18.5.1.1
mcmescPortHTotalCardShelfThe shelf the card is in. Valid values are: 1..2.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.18.5.1.2
mcmescPortHTotalCardSlotThe slot within the shelf the Module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.18.5.1.3
mcmescPortHTotalPortCPE port's index.ro
INTEGER
.1.3.6.1.4.1.4253.2.2.18.5.1.4
mcmescPortHTotalDurationMCMESC CPE port's total duration of up to 96 intervals.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.5.1.5
mcmescPortHTotalEnsMCMESC CPE port's total enabled seconds during up to 96 intervals.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.5.1.6
mcmescPortHTotalLossMCMESC CPE port's total loss of signal seconds during up to 96 intervals.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.5.1.7
mcmescPortHTotalCrcErrMCMESC CPE port's total CRC error counter during up to 96 intervals.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.5.1.8
mcmescPortHTotalOobErrMCMESC CPE port's total Out-Of-Band error counter during up to 96 intervals.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.5.1.9
mcmescPortHTotalRdpErrMCMESC CPE port's total Running Disparity error counter during up to 96 intervals.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.5.1.10
mcmescLinkHTotalTableThis table represents the information for each mcmesc cpe port's total counters of up to 96 intervals.
SEQUENCE OF McmescLinkHTotalEntry
.1.3.6.1.4.1.4253.2.2.18.6
mcmescLinkHTotalEntrySpecifies the index for each row in the table below
McmescLinkHTotalEntry
.1.3.6.1.4.1.4253.2.2.18.6.1
mcmescLinkHTotalCardLocationLocation of the MCMESC link port. Valid values are: Local in the same chassis, or remote to this chassisro
CardLocation
.1.3.6.1.4.1.4253.2.2.18.6.1.1
mcmescLinkHTotalCardShelfThe shelf the card is in. Valid values are: 1..2.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.18.6.1.2
mcmescLinkHTotalCardSlotThe slot within the shelf the Module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.18.6.1.3
mcmescLinkHTotalDurationMCMESC link port's total duration of up to 96 intervals.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.6.1.4
mcmescLinkHTotalTsosMCMESC link port's total test-sequence on seconds during up to 96 intervals.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.6.1.5
mcmescLinkHTotalLossMCMESC link port's total loss of signal seconds during up to 96 intervals.ro
Counter
.1.3.6.1.4.1.4253.2.2.18.6.1.6
mcmescLinkHTotalCrcErrMCMESC link port's total CRC error counter during up to 96 intervals.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.6.1.7
mcmescLinkHTotalOobErrMCMESC link port's total Out-Of-Band error counter during up to 96 intervals.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.6.1.8
mcmescLinkHTotalRdpErrMCMESC link port's total Running Disparity error counter during up to 96 intervals.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.18.6.1.9
tapHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.19
tapHistTableThis table represents the information for historical data collected for the TAP module.
SEQUENCE OF TapHistEntry
.1.3.6.1.4.1.4253.2.2.19.1
tapHistEntrySpecifies the index for each row in the table below
TapHistEntry
.1.3.6.1.4.1.4253.2.2.19.1.1
tapHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.19.1.1.1
tapHNumEventsTotal number of all traps (events) generated by all TAP modules.ro
Counter
.1.3.6.1.4.1.4253.2.2.19.1.1.2
tapHHistTableThis table represents the information for performance data collected for each TAP module
SEQUENCE OF TapHHistEntry
.1.3.6.1.4.1.4253.2.2.19.2
tapHHistEntrySpecifies the index for each row in the table below
TapHHistEntry
.1.3.6.1.4.1.4253.2.2.19.2.1
tapHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.19.2.1.1
tapHHistLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.19.2.1.2
tapHHistShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.19.2.1.3
tapHHistSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.19.2.1.4
tapHHistTypeModule type.ro
CardType
.1.3.6.1.4.1.4253.2.2.19.2.1.5
tapHLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.19.2.1.6
tapHAvailTimeThe number of seconds that this module has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.19.2.1.7
tapHErrFreeSecsThe number of seconds that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.19.2.1.8
voadmHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.20
voadmHistTableThis table represents the information for historical data collected for the VOADM module.
SEQUENCE OF VoadmHistEntry
.1.3.6.1.4.1.4253.2.2.20.1
voadmHistEntrySpecifies the index for each row in the table below
VoadmHistEntry
.1.3.6.1.4.1.4253.2.2.20.1.1
voadmHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.20.1.1.1
voadmHNumEventsTotal number of all traps (events) generated by all VOADM modules.ro
Counter
.1.3.6.1.4.1.4253.2.2.20.1.1.2
voadmHHistTableThis table represents the information for performance data collected for each VOADM module
SEQUENCE OF VoadmHHistEntry
.1.3.6.1.4.1.4253.2.2.20.2
voadmHHistEntrySpecifies the index for each row in the table below
VoadmHHistEntry
.1.3.6.1.4.1.4253.2.2.20.2.1
voadmHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.20.2.1.1
voadmHHistLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.20.2.1.2
voadmHHistShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.20.2.1.3
voadmHHistSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.20.2.1.4
voadmHHistTypeModule type.ro
CardType
.1.3.6.1.4.1.4253.2.2.20.2.1.5
voadmHLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.20.2.1.6
voadmHAvailTimeThe number of seconds that this module has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.20.2.1.7
voadmHErrFreeSecsThe number of seconds that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.20.2.1.8
dmmHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.21
dmmHistTableThis table represents the information for historical data collected for the DMM module.
SEQUENCE OF DmmHistEntry
.1.3.6.1.4.1.4253.2.2.21.1
dmmHistEntrySpecifies the index for each row in the table below
DmmHistEntry
.1.3.6.1.4.1.4253.2.2.21.1.1
dmmHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.21.1.1.1
dmmHNumEventsTotal number of all traps (events) generated by all DMM modules.ro
Counter
.1.3.6.1.4.1.4253.2.2.21.1.1.2
dmmHHistTableThis table represents the information for performance data collected for each DMM module
SEQUENCE OF DmmHHistEntry
.1.3.6.1.4.1.4253.2.2.21.2
dmmHHistEntrySpecifies the index for each row in the table below
DmmHHistEntry
.1.3.6.1.4.1.4253.2.2.21.2.1
dmmHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.21.2.1.1
dmmHHistLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.21.2.1.2
dmmHHistShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.21.2.1.3
dmmHHistSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.21.2.1.4
dmmHLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.21.2.1.5
dmmHAvailTimeThe number of seconds that this module has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.21.2.1.6
dmmHErrFreeSecsThe number of seconds that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.21.2.1.7
ocm10gfHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.22
ocm10gfHistTableThis table represents the information for historical data collected for the OCM10GF module.
SEQUENCE OF Ocm10gfHistEntry
.1.3.6.1.4.1.4253.2.2.22.1
ocm10gfHistEntrySpecifies the index for each row in the table below
Ocm10gfHistEntry
.1.3.6.1.4.1.4253.2.2.22.1.1
ocm10gfHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.22.1.1.1
ocm10gfHNumEventsTotal number of all traps (events) generated by all OCM10GF modules.ro
Counter
.1.3.6.1.4.1.4253.2.2.22.1.1.2
ocm10gfHHistTableThis table represents the information for performance data collected for each OCM10GF module
SEQUENCE OF Ocm10gfHHistEntry
.1.3.6.1.4.1.4253.2.2.22.2
ocm10gfHHistEntrySpecifies the index for each row in the table below
Ocm10gfHHistEntry
.1.3.6.1.4.1.4253.2.2.22.2.1
ocm10gfHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.22.2.1.1
ocm10gfHHistLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.22.2.1.2
ocm10gfHHistShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.22.2.1.3
ocm10gfHHistSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.22.2.1.4
ocm10gfHLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.22.2.1.5
ocm10gfHAvailTimeThe number of seconds that this module has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.22.2.1.6
ocm10gfHErrFreeSecsThe number of seconds that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.22.2.1.7
ocm2Hist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.23
ocm2HistTableThis table represents the information for historical data collected for the OCM2 module.
SEQUENCE OF Ocm2HistEntry
.1.3.6.1.4.1.4253.2.2.23.1
ocm2HistEntrySpecifies the index for each row in the table below
Ocm2HistEntry
.1.3.6.1.4.1.4253.2.2.23.1.1
ocm2HModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.23.1.1.1
ocm2HNumEventsTotal number of all traps (events) generated by all OCM2 modules.ro
Counter
.1.3.6.1.4.1.4253.2.2.23.1.1.2
ocm2HHistTableThis table represents the information for performance data collected for each OCM2 module
SEQUENCE OF Ocm2HHistEntry
.1.3.6.1.4.1.4253.2.2.23.2
ocm2HHistEntrySpecifies the index for each row in the table below
Ocm2HHistEntry
.1.3.6.1.4.1.4253.2.2.23.2.1
ocm2HHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.23.2.1.1
ocm2HHistLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.23.2.1.2
ocm2HHistShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.23.2.1.3
ocm2HHistSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.23.2.1.4
ocm2HLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.23.2.1.5
ocm2HAvailTimeThe number of seconds that this module has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.23.2.1.6
ocm2HErrFreeSecsThe number of seconds that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.23.2.1.7
oscHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.24
oscHistTableThis table represents the information for historical data collected for the OSC module.
SEQUENCE OF OscHistEntry
.1.3.6.1.4.1.4253.2.2.24.1
oscHistEntrySpecifies the index for each row in the table below
OscHistEntry
.1.3.6.1.4.1.4253.2.2.24.1.1
oscHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.24.1.1.1
oscHNumEventsTotal number of all traps (events) generated by all OSC modules.ro
Counter
.1.3.6.1.4.1.4253.2.2.24.1.1.2
oscHHistTableThis table represents the information for performance data collected for each OSC module
SEQUENCE OF OscHHistEntry
.1.3.6.1.4.1.4253.2.2.24.2
oscHHistEntrySpecifies the index for each row in the table below
OscHHistEntry
.1.3.6.1.4.1.4253.2.2.24.2.1
oscHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.24.2.1.1
oscHHistLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.24.2.1.2
oscHHistShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.24.2.1.3
oscHHistSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.24.2.1.4
oscHLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.24.2.1.5
oscHAvailTimeThe number of seconds that this module has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.24.2.1.6
oscHErrFreeSecsThe number of seconds that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.24.2.1.7
ocm4gHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.25
ocm4gHistTableThis table represents the information for historical data collected for the OCM4G module.
SEQUENCE OF Ocm4gHistEntry
.1.3.6.1.4.1.4253.2.2.25.1
ocm4gHistEntrySpecifies the index for each row in the table below
Ocm4gHistEntry
.1.3.6.1.4.1.4253.2.2.25.1.1
ocm4gHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.25.1.1.1
ocm4gHNumEventsTotal number of all traps (events) generated by all OCM4G modules.ro
Counter
.1.3.6.1.4.1.4253.2.2.25.1.1.2
ocm4gHHistTableThis table represents the information for performance data collected for each OCM4G module
SEQUENCE OF Ocm4gHHistEntry
.1.3.6.1.4.1.4253.2.2.25.2
ocm4gHHistEntrySpecifies the index for each row in the table below
Ocm4gHHistEntry
.1.3.6.1.4.1.4253.2.2.25.2.1
ocm4gHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.25.2.1.1
ocm4gHHistLocationThe location of the module. Choices are local or remote.ro
Enumeration
.1.3.6.1.4.1.4253.2.2.25.2.1.2
ocm4gHHistShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.25.2.1.3
ocm4gHHistSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.25.2.1.4
ocm4gHLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.25.2.1.5
ocm4gHAvailTimeThe number of seconds that this module has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.25.2.1.6
ocm4gHErrFreeSecsThe number of seconds that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.25.2.1.7
oetHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.26
uobHist
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.2.27
uobHistTableThis table represents the information for historical data collected for the UOB module.
SEQUENCE OF UobHistEntry
.1.3.6.1.4.1.4253.2.2.27.1
uobHistEntrySpecifies the index for each row in the table below
UobHistEntry
.1.3.6.1.4.1.4253.2.2.27.1.1
uobHModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.27.1.1.1
uobHNumEventsTotal number of all traps (events) generated by all UOB modules.ro
Counter
.1.3.6.1.4.1.4253.2.2.27.1.1.2
uobHHistTableThis table represents the information for performance data collected for each UOB module
SEQUENCE OF UobHHistEntry
.1.3.6.1.4.1.4253.2.2.27.2
uobHHistEntrySpecifies the index for each row in the table below
UobHHistEntry
.1.3.6.1.4.1.4253.2.2.27.2.1
uobHHistModeThe mode of the data collection. Valid values are: daily or longterm.ro
HistoryMode
.1.3.6.1.4.1.4253.2.2.27.2.1.1
uobHHistLocationThe location of the module. Choices are local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.2.2.27.2.1.2
uobHHistShelfThe shelf the module is in.ro
CardShelf
.1.3.6.1.4.1.4253.2.2.27.2.1.3
uobHHistSlotThe slot within the shelf the module is in.ro
CardSlot
.1.3.6.1.4.1.4253.2.2.27.2.1.4
uobHLastBootTimeThe date and time of the last boot for this module.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.2.2.27.2.1.5
uobHAvailTimeThe number of seconds that this module has been up and running.ro
Counter
.1.3.6.1.4.1.4253.2.2.27.2.1.6
uobHErrFreeSecsThe number of seconds that this module has not experienced any alarms.ro
Counter
.1.3.6.1.4.1.4253.2.2.27.2.1.7
specialConditions
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3
systemCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.1
sysCStatusThe global status of the system as computed based on the traps (events) that are generated. Choices are: Critical, Major, Minor or Normal.
CardStatus
.1.3.6.1.4.1.4253.2.3.1.1
sysCSetModeIf on, the special conditions counters will be activated. These counters continue counting until the mode is off. On startup, this flag is off.
FlagType
.1.3.6.1.4.1.4253.2.3.1.2
sysCAvailTimeThe number of seconds since this mode is started that the system has been up and running. The Criteria for the system available time is having at least one CP running with atmost non-service affecting minor alarm system status
Counter
.1.3.6.1.4.1.4253.2.3.1.3
sysCErrFreeSecsThe number of seconds since this mode is started that the device has not experienced any alarms. This counter is across all cards in the chassis. The system must be in Normal status for this counter to be incremented.
Counter
.1.3.6.1.4.1.4253.2.3.1.4
downloadCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.2
dlCStatusThe global status of the download task. The download task (download to the device) is either ftp-inprogress, module update inprogress or currently idle. Since only one download at the time is handled by the system, this flag is set to inprogress as soon as any download starts. It is reset back to idle when the download is completed. This flag is set to idle on system startup. This flag can be remotely set to idle if a previous FTP download was interrupted.
DownloadStatus
.1.3.6.1.4.1.4253.2.3.2.1
dlCOkDownloadsThe number of successful downloads in this time interval (15 minutes).
Counter
.1.3.6.1.4.1.4253.2.3.2.2
dlCBadDownloadsThe number of failed downloads in this time interval (15 minutes).
Counter
.1.3.6.1.4.1.4253.2.3.2.3
dlCLongestTimeLongest time for any download, in seconds, in this time interval (15 minutes).
Gauge
.1.3.6.1.4.1.4253.2.3.2.4
dlCLongestSizeLongest download size for any download, in bytes, in this time interval (15 minutes).
Gauge
.1.3.6.1.4.1.4253.2.3.2.5
dlCCounterFlagTurns software counters On or Off.
FlagType
.1.3.6.1.4.1.4253.2.3.2.6
cpCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.3
cpCNumEventsTotal number of events received by the active CP since this mode was activated.
Counter
.1.3.6.1.4.1.4253.2.3.3.1
cpCTrapsSentTotal number of traps sent by the active CP since this mode was activated.
Counter
.1.3.6.1.4.1.4253.2.3.3.2
cpCSNMPCmdsRcvdTotal number of SNMP commands received by the active CP since this mode was activated.
Counter
.1.3.6.1.4.1.4253.2.3.3.3
cpCCounterFlagTurns software counters On or Off.
FlagType
.1.3.6.1.4.1.4253.2.3.3.4
cpCCntrTableThis table represents the information for each entry for the software counters. It is only applicable to the active MPM card.
SEQUENCE OF CpCCntrEntry
.1.3.6.1.4.1.4253.2.3.3.5
cpCCntrEntrySpecifies the index for each row in the table below
CpCCntrEntry
.1.3.6.1.4.1.4253.2.3.3.5.1
cpCCntrShelfThe shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the value of the current active CP card.
CardShelf
.1.3.6.1.4.1.4253.2.3.3.5.1.1
cpCCntrSlotThe slot within the shelf the card is in. The system automatically determines the right value for this entry based on the value of the current active CP card.
CardSlot
.1.3.6.1.4.1.4253.2.3.3.5.1.2
cpCCntrTypeThe type of the software counter data in this row. The data is collected for the SPI data channels.
Enumeration
.1.3.6.1.4.1.4253.2.3.3.5.1.3
cpCTotPktSentThe number of data packets sent over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.3.5.1.4
cpCTotPktRcvdThe number of data packets received over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.3.5.1.5
cpCBadPktRcvdThe number of bad data packets received over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.3.5.1.6
cpCTotBadTransThe number of bad data transmissions over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.3.5.1.7
cpCBytesSentTotal number of bytes sent over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.3.5.1.8
cpCBytesRcvdTotal number of data bytes received over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.3.5.1.9
cpCMsgsDlvrdThe number of complete messages delivered over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.3.5.1.10
cpCBufAllocFailNumber of buffer allocation failures for the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.3.5.1.11
cpCEcbAllocFailNumber of Event Control Block allocation failures for the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.3.5.1.12
cpCPerfTableThis table represents the information for performance data collected for each communication processor
SEQUENCE OF CpCPerfEntry
.1.3.6.1.4.1.4253.2.3.3.6
cpCPerfEntrySpecifies the index for each row in the table below
CpCPerfEntry
.1.3.6.1.4.1.4253.2.3.3.6.1
cpCPerfShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.3.3.6.1.1
cpCPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.3.6.1.2
cpCPerfModeThe valid types are: active CP or standby CP
RedundancyMode
.1.3.6.1.4.1.4253.2.3.3.6.1.3
cpCPerfStateThe state of the communication card. The states are: online, offline, empty, loopback or diagnostics.
CardState
.1.3.6.1.4.1.4253.2.3.3.6.1.4
cpCPerfStatusThe status of the communication processor. This status represents the state of the communication processor and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.3.6.1.5
cpCAvailTimeThe number of seconds since this mode is started that this CP has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.3.3.6.1.7
cpCErrFreeSecsThe number of seconds since this mode is started that this CP has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.3.6.1.8
ccCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.4
ccCNumEventsTotal number of events received for all CC's since this mode was started.
Counter
.1.3.6.1.4.1.4253.2.3.4.1
ccCCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF CcCCntrEntry
.1.3.6.1.4.1.4253.2.3.4.2
ccCCntrEntrySpecifies the index for each row in the table below
CcCCntrEntry
.1.3.6.1.4.1.4253.2.3.4.2.1
ccCCntrLocationThe location of the CC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known CC cards.
CardLocation
.1.3.6.1.4.1.4253.2.3.4.2.1.1
ccCCntrShelfThe shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the known (available) CC cards.
CardShelf
.1.3.6.1.4.1.4253.2.3.4.2.1.2
ccCCntrSlotThe slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) CC cards.
CardSlot
.1.3.6.1.4.1.4253.2.3.4.2.1.3
ccCCntrTypeThe type of the software counter data in this row. The data is collected for the SPI data channels.
Enumeration
.1.3.6.1.4.1.4253.2.3.4.2.1.4
ccCCounterFlagTurns software counters, both On or both Off for this CC. When Off Clears both counters Statistic information
FlagType
.1.3.6.1.4.1.4253.2.3.4.2.1.5
ccCTotPktSentThe number of data packets sent over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.4.2.1.6
ccCTotPktRcvdThe number of data packets received over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.4.2.1.7
ccCBadPktRcvdThe number of bad data packets received over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.4.2.1.8
ccCTotBadTransThe number of bad data transmissions over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.4.2.1.9
ccCBytesSentTotal number of bytes sent over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.4.2.1.10
ccCBytesRcvdTotal number of data bytes received over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.4.2.1.11
ccCMsgsDlvrdThe number of complete messages delivered over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.4.2.1.12
ccCBufAllocFailNumber of buffer allocation failures for the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.4.2.1.13
ccCEcbAllocFailNumber of Event Control Block allocation failures for the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.4.2.1.14
ccCClearCntrsIf the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other.
ResetType
.1.3.6.1.4.1.4253.2.3.4.2.1.15
ccCPerfTableThis table represents the information for performance data collected for each channel card.
SEQUENCE OF CcCPerfEntry
.1.3.6.1.4.1.4253.2.3.4.3
ccCPerfEntrySpecifies the index for each row in the table below
CcCPerfEntry
.1.3.6.1.4.1.4253.2.3.4.3.1
ccCPerfLocationThe location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards.
CardLocation
.1.3.6.1.4.1.4253.2.3.4.3.1.1
ccCPerfShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.3.4.3.1.2
ccCPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.4.3.1.3
ccCPerfStateThe state of the channel card. The states' are: online, offline, empty, loopback or diagnostics.
CardState
.1.3.6.1.4.1.4253.2.3.4.3.1.4
ccCPerfStatusThe status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.4.3.1.5
ccCAvailTimeThe number of seconds in this time slot (15 minutes) that this CC has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.3.4.3.1.6
ccCErrFreeSecsThe number of seconds in this time slot (15 minutes) that this CC has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.4.3.1.7
ccCBiasCurrentBias current for the optical laser.
INTEGER
.1.3.6.1.4.1.4253.2.3.4.3.1.8
ccCModulationThe frequency modulation for the optical laser.
INTEGER
.1.3.6.1.4.1.4253.2.3.4.3.1.9
ccCApcThe APC value.
INTEGER
.1.3.6.1.4.1.4253.2.3.4.3.1.10
ccCIwmModulationThe frequency modulation for the IWM channel.
INTEGER
.1.3.6.1.4.1.4253.2.3.4.3.1.11
ccCLaserOnOffThe laser On/Off flag.
FlagType
.1.3.6.1.4.1.4253.2.3.4.3.1.12
ccCTemperatureThe current temperature, or the operating temperature of the optical device.
Gauge
.1.3.6.1.4.1.4253.2.3.4.3.1.13
ccCIntensityThe intensity of the optical light.
Gauge
.1.3.6.1.4.1.4253.2.3.4.3.1.14
ccCSignalStrengthThe current signal strength for the optical path.
Gauge
.1.3.6.1.4.1.4253.2.3.4.3.1.15
ccCLossOfLightIf set to true, no laser light is present. If set to false, no loss of light has occurred.
Boolean
.1.3.6.1.4.1.4253.2.3.4.3.1.16
ccCSignalDetectIf set to true, signal is detected. If set to false, no signal is present.
Boolean
.1.3.6.1.4.1.4253.2.3.4.3.1.17
ccCRefClockThe value of the reference clock in decimal notation. For a given value, like 1660, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor.
Enumeration
.1.3.6.1.4.1.4253.2.3.4.3.1.18
ccCClockDivThe clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale.
Enumeration
.1.3.6.1.4.1.4253.2.3.4.3.1.19
ccCProtectionModeUPSR Protection Mode: active, standby and na.
Enumeration
.1.3.6.1.4.1.4253.2.3.4.3.1.20
muxCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.5
muxCNumEventsTotal number of all traps (events) generated by all MUX's since this mode is started.
Counter
.1.3.6.1.4.1.4253.2.3.5.1
muxCPerfTableThis table represents the information for performance data collected for each mux/demux card
SEQUENCE OF MuxCPerfEntry
.1.3.6.1.4.1.4253.2.3.5.2
muxCPerfEntrySpecifies the index for each row in the table below
MuxCPerfEntry
.1.3.6.1.4.1.4253.2.3.5.2.1
muxCPerfLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.3.5.2.1.1
muxCPerfShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.3.5.2.1.2
muxCPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.5.2.1.3
muxCTypeThe type of the mux. The choices are: mux or demux.
Enumeration
.1.3.6.1.4.1.4253.2.3.5.2.1.4
muxCPerfStateThe status of the mux card. The states are: online, offline, empty, loopback or diag.
CardState
.1.3.6.1.4.1.4253.2.3.5.2.1.5
muxCPerfStatusThe status of the mux card. This status represents the status of the mux card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.5.2.1.6
muxCAvailTimeThe number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.3.5.2.1.7
muxCErrFreeSecsThe number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.5.2.1.8
muxCCounterFlagTurns special condition software counters On or Off for this card. Default is off.
FlagType
.1.3.6.1.4.1.4253.2.3.5.3
psCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.6
psCNumEventsTotal number of all traps (events) generated by all Power Supplies since this mode is started.
Counter
.1.3.6.1.4.1.4253.2.3.6.1
psCVoltageLevel3pt3VoltVoltage Level of the 3.3 V power supply. Need to divide this value by ten to get the actual voltage level.
INTEGER
.1.3.6.1.4.1.4253.2.3.6.2
psCVoltageLevel5VoltVoltage Level of the 5 V power supply. Need to divide this value by ten to get the actual voltage level.
INTEGER
.1.3.6.1.4.1.4253.2.3.6.3
psCVoltageLevel12VoltVoltage Level of the 12 V power supply. Need to divide this value by ten to get the actual voltage level.
INTEGER
.1.3.6.1.4.1.4253.2.3.6.4
psCPerfTableThis table represents the information for performance data collected for each power supply card
SEQUENCE OF PsCPerfEntry
.1.3.6.1.4.1.4253.2.3.6.5
psCPerfEntrySpecifies the index for each row in the table below
PsCPerfEntry
.1.3.6.1.4.1.4253.2.3.6.5.1
psCPerfIDThe module id where ps is in. Valid values are: 1 to 4
INTEGER
.1.3.6.1.4.1.4253.2.3.6.5.1.1
psCPerfTypeThe type of the power supply card. The choices are: active (primary PS) or standby.
RedundancyMode
.1.3.6.1.4.1.4253.2.3.6.5.1.2
psCPerfStateThe state of the power supply card. The states are: online, offline, empty, loopback or diagnostics.
CardState
.1.3.6.1.4.1.4253.2.3.6.5.1.3
psCPerfStatusThe status of the power supply card. This status represents the status of the ps card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.6.5.1.4
fadmCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.7
fadmCNumEventsTotal number of all traps (events) generated by all FADM's since this mode is started.
Counter
.1.3.6.1.4.1.4253.2.3.7.1
fadmCCounterFlagTurns software counters On or Off for this FADM.
FlagType
.1.3.6.1.4.1.4253.2.3.7.2
fadmCPerfTableThis table represents the information for performance data collected for each fadm card
SEQUENCE OF FadmCPerfEntry
.1.3.6.1.4.1.4253.2.3.7.3
fadmCPerfEntrySpecifies the index for each row in the table below
FadmCPerfEntry
.1.3.6.1.4.1.4253.2.3.7.3.1
fadmCPerfLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.3.7.3.1.1
fadmCPerfShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.3.7.3.1.2
fadmCPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.7.3.1.3
fadmCPerfStateThe status of the mux card. The states are: online, offline, empty, loopback or diag.
CardState
.1.3.6.1.4.1.4253.2.3.7.3.1.5
fadmCPerfStatusThe status of the mux card. This status represents the status of the mux card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.7.3.1.6
fadmCAvailTimeThe number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.3.7.3.1.7
fadmCErrFreeSecsThe number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.7.3.1.8
oppmCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.8
oppmCNumEventsTotal number of all traps (events) generated by all OPPMs' since this mode is started.
Counter
.1.3.6.1.4.1.4253.2.3.8.1
oppmCPerfTableThis table represents the information for performance data collected for each oppm card
SEQUENCE OF OppmCPerfEntry
.1.3.6.1.4.1.4253.2.3.8.2
oppmCPerfEntrySpecifies the index for each row in the table below
OppmCPerfEntry
.1.3.6.1.4.1.4253.2.3.8.2.1
oppmCPerfLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.3.8.2.1.1
oppmCPerfShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.3.8.2.1.2
oppmCPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.8.2.1.3
oppmCPerfStateThe status of the oppm card. The states are: online, offline, empty, loopback or diag.
CardState
.1.3.6.1.4.1.4253.2.3.8.2.1.4
oppmCPerfStatusThe status of the oppm card. This status represents the status of the oppm card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.8.2.1.5
oppmCAvailTimeThe number of seconds in this time slot (15 minutes) that this oppm has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.3.8.2.1.6
oppmCErrFreeSecsThe number of seconds in this time slot (15 minutes) that this oppm has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.8.2.1.7
oppmCCounterFlagTurns special condition software counters On or Off for this card. Default is off.
FlagType
.1.3.6.1.4.1.4253.2.3.8.3
mcmCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.9
mcmCNumEventsTotal number of events received for all MCM's since this mode was started.
Counter
.1.3.6.1.4.1.4253.2.3.9.1
mcmCCntrTableThis table represents the information for each entry for the software counters.
SEQUENCE OF McmCCntrEntry
.1.3.6.1.4.1.4253.2.3.9.2
mcmCCntrEntrySpecifies the index for each row in the table below
McmCCntrEntry
.1.3.6.1.4.1.4253.2.3.9.2.1
mcmCCntrLocationThe location of the MCM card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known MCM cards.
CardLocation
.1.3.6.1.4.1.4253.2.3.9.2.1.1
mcmCCntrShelfThe shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the known (available) MCM cards.
CardShelf
.1.3.6.1.4.1.4253.2.3.9.2.1.2
mcmCCntrSlotThe slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) MCM cards.
CardSlot
.1.3.6.1.4.1.4253.2.3.9.2.1.3
mcmCCntrTypeThe type of the software counter data in this row. The data is collected for the SPI data channels.
Enumeration
.1.3.6.1.4.1.4253.2.3.9.2.1.4
mcmCCounterFlagTurns software counters On or Off for this MCM.
FlagType
.1.3.6.1.4.1.4253.2.3.9.2.1.5
mcmCTotPktSentThe number of data packets sent over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.9.2.1.6
mcmCTotPktRcvdThe number of data packets received over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.9.2.1.7
mcmCBadPktRcvdThe number of bad data packets received over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.9.2.1.8
mcmCTotBadTransThe number of bad data transmissions over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.9.2.1.9
mcmCBytesSentTotal number of bytes sent over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.9.2.1.10
mcmCBytesRcvdTotal number of data bytes received over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.9.2.1.11
mcmCMsgsDlvrdThe number of complete messages delivered over the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.9.2.1.12
mcmCBufAllocFailNumber of buffer allocation failures for the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.9.2.1.13
mcmCEcbAllocFailNumber of Event Control Block allocation failures for the given data channel.
Counter
.1.3.6.1.4.1.4253.2.3.9.2.1.14
mcmCClearCntrsIf the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other.
ResetType
.1.3.6.1.4.1.4253.2.3.9.2.1.15
mcmCPerfTableThis table represents the information for performance data collected for each channel card
SEQUENCE OF McmCPerfEntry
.1.3.6.1.4.1.4253.2.3.9.3
mcmCPerfEntrySpecifies the index for each row in the table below
McmCPerfEntry
.1.3.6.1.4.1.4253.2.3.9.3.1
mcmCPerfLocationThe location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards.
CardLocation
.1.3.6.1.4.1.4253.2.3.9.3.1.1
mcmCPerfShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.3.9.3.1.2
mcmCPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.9.3.1.3
mcmCPerfStateThe state of the channel card. The states' are: online, offline, empty, loopback or diagnostics.
CardState
.1.3.6.1.4.1.4253.2.3.9.3.1.4
mcmCPerfStatusThe status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.9.3.1.5
mcmCAvailTimeThe number of seconds in this time slot (15 minutes) that this CC has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.3.9.3.1.6
mcmCErrFreeSecsThe number of seconds in this time slot (15 minutes) that this MCM has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.9.3.1.7
mcmCBiasCurrentBias current for the optical laser.
INTEGER
.1.3.6.1.4.1.4253.2.3.9.3.1.8
mcmCModulationThe frequency modulation for the optical laser.
INTEGER
.1.3.6.1.4.1.4253.2.3.9.3.1.9
mcmCApcThe APC value.
INTEGER
.1.3.6.1.4.1.4253.2.3.9.3.1.10
mcmCIwmModulationThe frequency modulation for the IWM channel.
INTEGER
.1.3.6.1.4.1.4253.2.3.9.3.1.11
mcmCLaserOnOffThe laser On/Off flag.
FlagType
.1.3.6.1.4.1.4253.2.3.9.3.1.12
mcmCTemperatureThe current temperature, or the operating temperature of the optical device.
Gauge
.1.3.6.1.4.1.4253.2.3.9.3.1.13
mcmCIntensityThe intensity of the optical light.
Gauge
.1.3.6.1.4.1.4253.2.3.9.3.1.14
mcmCSignalStrengthThe current signal strength for the optical path.
Gauge
.1.3.6.1.4.1.4253.2.3.9.3.1.15
mcmCLossOfLightIf set to true, no laser light is present. If set to false, no loss of light has occurred.
Boolean
.1.3.6.1.4.1.4253.2.3.9.3.1.16
mcmCSignalDetectIf set to true, signal is detected. If set to false, no signal is present.
Boolean
.1.3.6.1.4.1.4253.2.3.9.3.1.17
mcmCRefClockThe value of the reference clock in decimal notation. For a given value, like 1660, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor.
Enumeration
.1.3.6.1.4.1.4253.2.3.9.3.1.18
mcmCClockDivThe clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale.
Enumeration
.1.3.6.1.4.1.4253.2.3.9.3.1.19
mcmPortCCntrTableThis table represents the information for each MCM port's current counters.
SEQUENCE OF McmPortCCntrEntry
.1.3.6.1.4.1.4253.2.3.9.4
mcmPortCCntrEntrySpecifies the index for each row in the table below
McmPortCCntrEntry
.1.3.6.1.4.1.4253.2.3.9.4.1
mcmPortCCntrCardLocationLocation of the MCM port. Valid values are: Local in the same chassis, or remote to this chassis
CardLocation
.1.3.6.1.4.1.4253.2.3.9.4.1.1
mcmPortCCntrCardShelfThe shelf the card is in. Valid values are: 2..3.
CardShelf
.1.3.6.1.4.1.4253.2.3.9.4.1.2
mcmPortCCntrCardSlotThe slot within the shelf the Module is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.9.4.1.3
mcmPortCCntrIndexPort's index.
INTEGER
.1.3.6.1.4.1.4253.2.3.9.4.1.4
mcmPortCCntrASsmcm port's ASs counter less than 15 mins.
Counter
.1.3.6.1.4.1.4253.2.3.9.4.1.5
mcmPortCCntrFEsMCM port's FEs counter less than 15 mins.
Counter
.1.3.6.1.4.1.4253.2.3.9.4.1.7
mcmPortCCntrCRCErrsMCM port's CRC errs counter less than 15 mins.
Counter
.1.3.6.1.4.1.4253.2.3.9.4.1.8
mcmPortCCntrSESsmcm port's SESs counter less than 15 mins.
Counter
.1.3.6.1.4.1.4253.2.3.9.4.1.9
mcmPortCCntrSEFSsMCM port's SEFSs counter less than 15 mins.
Counter
.1.3.6.1.4.1.4253.2.3.9.4.1.10
mcmPortCCntrUASsMCM port's UASs counter less than 15 mins.
Counter
.1.3.6.1.4.1.4253.2.3.9.4.1.11
mcmPortCCntrLESsMCM port's LESs counter less than 15 mins.
Counter
.1.3.6.1.4.1.4253.2.3.9.4.1.12
mcmPortCCntrBESsMCM port's BESs counter less than 15 mins.
Counter
.1.3.6.1.4.1.4253.2.3.9.4.1.13
mcmPortCCntrDMsMCM port's DMSs counter less than 15 mins.
Counter
.1.3.6.1.4.1.4253.2.3.9.4.1.14
mcmPortCCntrLCVsMCM port's LCVs counter less than 15 mins.
Counter
.1.3.6.1.4.1.4253.2.3.9.4.1.15
fnCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.10
fnCNumEventsTotal number of all traps (events) generated by all Fans since this mode is started.
Counter
.1.3.6.1.4.1.4253.2.3.10.1
fnCPerfTableThis table represents the information for performance data collected for each fan module.
SEQUENCE OF FnCPerfEntry
.1.3.6.1.4.1.4253.2.3.10.2
fnCPerfEntrySpecifies the index for each row in the table below
FnCPerfEntry
.1.3.6.1.4.1.4253.2.3.10.2.1
fnCPerfIDThe module ID where the fan module is plugged in.
INTEGER
.1.3.6.1.4.1.4253.2.3.10.2.1.1
fnCPerfStateThe state of the fan module.
Enumeration
.1.3.6.1.4.1.4253.2.3.10.2.1.2
fnCPerfStatusThe status of the fan module. This status represents the status of the fan module and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.10.2.1.3
rpsmCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.12
rpsmCNumEventsTotal number of all traps (events) generated by all RPSMs' since this mode is started.
Counter
.1.3.6.1.4.1.4253.2.3.12.1
rpsmCPerfTableThis table represents the information for performance data collected for each rpsm card
SEQUENCE OF RpsmCPerfEntry
.1.3.6.1.4.1.4253.2.3.12.2
rpsmCPerfEntrySpecifies the index for each row in the table below
RpsmCPerfEntry
.1.3.6.1.4.1.4253.2.3.12.2.1
rpsmCPerfLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.3.12.2.1.1
rpsmCPerfShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.3.12.2.1.2
rpsmCPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.12.2.1.3
rpsmCPerfStateThe state of the rpsm card. The states are: online, offline, empty, loopback or diag.
CardState
.1.3.6.1.4.1.4253.2.3.12.2.1.4
rpsmCPerfStatusThe status of the rpsm card. This status represents the status of the rpsm card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.12.2.1.5
rpsmCAvailTimeThe number of seconds in this time slot (15 minutes) that this rpsm has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.3.12.2.1.6
rpsmCErrFreeSecsThe number of seconds in this time slot (15 minutes) that this rpsm has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.12.2.1.7
rpsmCCounterFlagTurns special condition software counters On or Off for this card. Default is off.
FlagType
.1.3.6.1.4.1.4253.2.3.12.3
rsdmCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.13
rsdmCNumEventsTotal number of all traps (events) generated by all RSDMs' since this mode is started.
Counter
.1.3.6.1.4.1.4253.2.3.13.1
rsdmCPerfTableThis table represents the information for performance data collected for each oppm card
SEQUENCE OF RsdmCPerfEntry
.1.3.6.1.4.1.4253.2.3.13.2
rsdmCPerfEntrySpecifies the index for each row in the table below
RsdmCPerfEntry
.1.3.6.1.4.1.4253.2.3.13.2.1
rsdmCPerfLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.3.13.2.1.1
rsdmCPerfShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.3.13.2.1.2
rsdmCPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.13.2.1.3
rsdmCPerfStateThe state of the rsdm card. The states are: online, offline, empty, loopback or diag.
CardState
.1.3.6.1.4.1.4253.2.3.13.2.1.4
rsdmCPerfStatusThe status of the rsdm card. This status represents the status of the rsdm card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.13.2.1.5
rsdmCAvailTimeThe number of seconds in this time slot (15 minutes) that this rsdm has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.3.13.2.1.6
rsdmCErrFreeSecsThe number of seconds in this time slot (15 minutes) that this rsdm has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.13.2.1.7
rsdmCCounterFlagTurns special condition software counters On or Off for this card. Default is off.
FlagType
.1.3.6.1.4.1.4253.2.3.13.3
rtdmCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.14
rtdmCNumEventsTotal number of all traps (events) generated by all RTDM's since this mode is started.
Counter
.1.3.6.1.4.1.4253.2.3.14.1
rtdmCPerfTableThis table represents the information for performance data collected for each mux/demux card
SEQUENCE OF RtdmCPerfEntry
.1.3.6.1.4.1.4253.2.3.14.2
rtdmCPerfEntrySpecifies the index for each row in the table below
RtdmCPerfEntry
.1.3.6.1.4.1.4253.2.3.14.2.1
rtdmCPerfLocationThe location of the card. Choices are local or remote.
CardLocation
.1.3.6.1.4.1.4253.2.3.14.2.1.1
rtdmCPerfShelfThe shelf the card is in. Valid values are: 1 to 10
CardShelf
.1.3.6.1.4.1.4253.2.3.14.2.1.2
rtdmCPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.14.2.1.3
rtdmCPerfStateThe status of the mux card. The states are: online, offline, empty, loopback or diag.
CardState
.1.3.6.1.4.1.4253.2.3.14.2.1.4
rtdmCPerfStatusThe status of the mux card. This status represents the status of the mux card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.14.2.1.5
rtdmCAvailTimeThe number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.3.14.2.1.6
rtdmCErrFreeSecsThe number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.14.2.1.7
rtdmCCounterFlagTurns special condition software counters On or Off for this card. Default is off.
FlagType
.1.3.6.1.4.1.4253.2.3.14.3
osamCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.15
osamCNumEventsTotal number of events received for all osam's since this mode was started.
Counter
.1.3.6.1.4.1.4253.2.3.15.1
osamCPerfTableThis table represents the information for special conditions performance data collected for each osam module.
SEQUENCE OF OsamCPerfEntry
.1.3.6.1.4.1.4253.2.3.15.2
osamCPerfEntrySpecifies the index for each row in the table below
OsamCPerfEntry
.1.3.6.1.4.1.4253.2.3.15.2.1
osamCPerfLocationLocation of the module.
CardLocation
.1.3.6.1.4.1.4253.2.3.15.2.1.1
osamCPerfShelfThe shelf number in which the module is plugged in.
CardShelf
.1.3.6.1.4.1.4253.2.3.15.2.1.2
osamCPerfSlotThe slot number in which the module is plugged in.
INTEGER
.1.3.6.1.4.1.4253.2.3.15.2.1.3
osamCPerfStateThe current state of the module.
CardState
.1.3.6.1.4.1.4253.2.3.15.2.1.4
osamCPerfStatusThe current alarm status of the channel.
CardStatus
.1.3.6.1.4.1.4253.2.3.15.2.1.5
osamCPerfAvailTimeThe number of seconds since the start of this mode that this module has been up and running.
Counter
.1.3.6.1.4.1.4253.2.3.15.2.1.6
osamCPerfErrFreeSecsThe number of seconds since the start of this mode that this module has been experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.15.2.1.7
osamCPerfCounterFlagTurns osam special condition software counters on and off. Default is off.
FlagType
.1.3.6.1.4.1.4253.2.3.15.3
rsmCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.16
rsmCNumEventsTotal number of all traps (events) generated by all RSMs' since this mode is started.
Counter
.1.3.6.1.4.1.4253.2.3.16.1
rsmCPerfTableThis table represents the information for performance data collected for each rsm card
SEQUENCE OF RsmCPerfEntry
.1.3.6.1.4.1.4253.2.3.16.2
rsmCPerfEntrySpecifies the index for each row in the table below
RsmCPerfEntry
.1.3.6.1.4.1.4253.2.3.16.2.1
rsmCPerfLocationThe location of the card.
CardLocation
.1.3.6.1.4.1.4253.2.3.16.2.1.1
rsmCPerfShelfThe shelf the card is in.
CardShelf
.1.3.6.1.4.1.4253.2.3.16.2.1.2
rsmCPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.16.2.1.3
rsmCPerfStateThe state of the rsm card. The states are: online, offline, empty, loopback or diag.
CardState
.1.3.6.1.4.1.4253.2.3.16.2.1.4
rsmCPerfStatusThe status of the rsm card. This status represents the status of the rsm card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.16.2.1.5
rsmCAvailTimeThe number of seconds in this time slot (15 minutes) that this rsm has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.3.16.2.1.6
rsmCErrFreeSecsThe number of seconds in this time slot (15 minutes) that this rsm has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.16.2.1.7
rsmCCounterFlagTurns special condition software counters On or Off for this card. Default is off.
FlagType
.1.3.6.1.4.1.4253.2.3.16.3
upsmCond
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.2.3.17
upsmCNumEventsTotal number of all traps (events) generated by all UPSMs' since this mode is started.
Counter
.1.3.6.1.4.1.4253.2.3.17.1
upsmCPerfTableThis table represents the information for performance data collected for each upsm card
SEQUENCE OF UpsmCPerfEntry
.1.3.6.1.4.1.4253.2.3.17.2
upsmCPerfEntrySpecifies the index for each row in the table below
UpsmCPerfEntry
.1.3.6.1.4.1.4253.2.3.17.2.1
upsmCPerfLocationThe location of the card.
CardLocation
.1.3.6.1.4.1.4253.2.3.17.2.1.1
upsmCPerfShelfThe shelf the card is in.
CardShelf
.1.3.6.1.4.1.4253.2.3.17.2.1.2
upsmCPerfSlotThe slot within the shelf the card is in.
CardSlot
.1.3.6.1.4.1.4253.2.3.17.2.1.3
upsmCPerfStateThe state of the upsm card. The states are: online, offline, empty, loopback or diag.
CardState
.1.3.6.1.4.1.4253.2.3.17.2.1.4
upsmCPerfStatusThe status of the upsm card. This status represents the status of the upsm card and in general is different from the status of the system.
CardStatus
.1.3.6.1.4.1.4253.2.3.17.2.1.5
upsmCAvailTimeThe number of seconds in this time slot (15 minutes) that this upsm has been up and running. This will generally be the same as 15 minutes in seconds (900).
Counter
.1.3.6.1.4.1.4253.2.3.17.2.1.6
upsmCErrFreeSecsThe number of seconds in this time slot (15 minutes) that this upsm has not experienced any alarms.
Counter
.1.3.6.1.4.1.4253.2.3.17.2.1.7
upsmCCounterFlagTurns special condition software counters On or Off for this card. Default is off.
FlagType
.1.3.6.1.4.1.4253.2.3.17.3
faults
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.3
eventLog
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.3.1
eveTrapThresholdThreshold before events of the same type are no longer sent. Default can be a number as small as 1.
INTEGER
.1.3.6.1.4.1.4253.3.1.1
eveNumEventsNumber of events logged in the table below. This counter is automatically set by the software.ro
EventBuffer
.1.3.6.1.4.1.4253.3.1.2
eveLogTableThis table represents the information for the event log buffer. There are a maximum of 700 entries in the event log. The events are kept in a circular buffer fashion with eveSeqNum going from 1 to 9999.
SEQUENCE OF EveLogEntry
.1.3.6.1.4.1.4253.3.1.3
eveLogEntrySpecifies the index for each row in the table below
EveLogEntry
.1.3.6.1.4.1.4253.3.1.3.1
eveDateTimeThe date and time of the event logged in the bufferro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.1.3.1.1
eveEventIdThe event ID assigned to this event.ro
INTEGER
.1.3.6.1.4.1.4253.3.1.3.1.2
eveSeverityThe severity of this event. Could be critical, major, minor, or normal (informational).ro
TrapStatus
.1.3.6.1.4.1.4253.3.1.3.1.3
eveSysStatusThe current status of the system. Could be critical, major, minor, or normal (informational).ro
CardStatus
.1.3.6.1.4.1.4253.3.1.3.1.4
eveSourceA five to seven tuple string composed of the following items: System Name:card type (MPM, OCMITU, OFCM, etc.). location (L for local, R[number] for remote with optional station number). shelf #. slot id[. port #][:link name(optional depending on card type)] [:ring name(optional)] [:path name(optional)]. When an event applies to all slots of the whole chassis, 0 will be displayed for both shelf and slot. Example: SystemInSunnyvale:OCMITU.L.1.6:ITU23ro
DisplayString
.1.3.6.1.4.1.4253.3.1.3.1.5
eveDescrA string signifying the cause of the error in natural language (preferrably English) format.ro
DisplayString
.1.3.6.1.4.1.4253.3.1.3.1.6
eveTrapIf set to True, this event was sent as a trap. If set to False, this event was merely logged and not sent as a trap.ro
Boolean
.1.3.6.1.4.1.4253.3.1.3.1.7
eveSeqNumThe unique sequence number for this event entry in the event log.ro
INTEGER
.1.3.6.1.4.1.4253.3.1.3.1.8
eveDeleteLogIf the value is reset, the event log table of the active cp is deleted - meaning all the log entries are flushed!!rw
ResetType
.1.3.6.1.4.1.4253.3.1.4
eveLastEntryDateTimeDate and time stamp of the last event log entry. This provides quick access into the last event log entry.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.1.5
eveHundredthEntryDateTimeDate and time stamp of the most recent 100th event log entry. This provides quick access into retrieving the most recent 100 event log entries. If less than 100 entries exist in the event log, the return value contains all zeroes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.1.6
eveTwoHundredthEntryDateTimeDate and time stamp of the most recent 200th event log entry. This provides quick access into retrieving the most recent 200 event log entries. If less than 200 entries exist in the event log, the return value contains all zeroes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.1.7
eveThreeHundredthEntryDateTimeDate and time stamp of the most recent 300th event log entry. This provides quick access into retrieving the most recent 300 event log entries. If less than 300 entries exist in the event log, the return value contains all zeroes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.1.8
eveFourHundredthEntryDateTimeDate and time stamp of the most recent 400th event log entry. This provides quick access into retrieving the most recent 400 event log entries. If less than 400 entries exist in the event log, the return value contains all zeroes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.1.9
eveFiveHundredthEntryDateTimeDate and time stamp of the most recent 500th event log entry. This provides quick access into retrieving the most recent 500 event log entries. If less than 500 entries exist in the event log, the return value contains all zeroes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.1.10
eveSixHundredthEntryDateTimeDate and time stamp of the most recent 600th event log entry. This provides quick access into retrieving the most recent 600 event log entries. If less than 600 entries exist in the event log, the return value contains all zeroes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.1.11
eveSevenHundredthEntryDateTimeDate and time stamp of the most recent 700th event log entry. This provides quick access into retrieving the most recent 700 event log entries. If less than 700 entries exist in the event log, the return value contains all zeroes.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.1.12
eveEightHundredthEntryDateTimeDate and time stamp of the most recent 800th event log entry. This provides quick access into retrieving the most recent 800 event log entries. If less than 800 entries exist in the event log, the return value contains all zeroes.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.1.13
eveNineHundredthEntryDateTimeDate and time stamp of the most recent 900th event log entry. This provides quick access into retrieving the most recent 900 event log entries. If less than 900 entries exist in the event log, the return value contains all zeroes.
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.1.14
userLog
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.3.2
usrNumLogsNumber of user events logged in the table below. This counter is automatically set by the software.
UserBuffer
.1.3.6.1.4.1.4253.3.2.1
usrLogTableThis table represents the information for user event log buffer
SEQUENCE OF UsrLogEntry
.1.3.6.1.4.1.4253.3.2.2
usrLogEntrySpecifies the index for each row in the table below
UsrLogEntry
.1.3.6.1.4.1.4253.3.2.2.1
usrDateTimeThe date and time of the event logged in the buffer
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.2.2.1.1
usrLogonIdThe Logon ID of the user causing this event to be logged.
LogonID
.1.3.6.1.4.1.4253.3.2.2.1.2
usrTargetA four tuple string composed of the following items: location (remote or local), type (cp, cc, mux or ps), shelf, and slot id. The tuples are separated by comma. Example: local,cp,b,1. This column identifies which subsystem was affected by the user action.
DisplayString
.1.3.6.1.4.1.4253.3.2.2.1.3
usrLogDescrA string signifying the action logged in natural language (preferrably English) format.
DisplayString
.1.3.6.1.4.1.4253.3.2.2.1.4
usrTrapIf set to True, this user event was sent as a trap. If set to False, this event was merely logged and not sent as a trap.
Boolean
.1.3.6.1.4.1.4253.3.2.2.1.5
diagnostics
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.3.3
diagModeNumNumber of cards in diagnostics mode in the table below. This counter is automatically set by the software.ro
INTEGER
.1.3.6.1.4.1.4253.3.3.1
diagModeTableThis table represents the information for each card in diagnostics mode.
SEQUENCE OF DiagModeEntry
.1.3.6.1.4.1.4253.3.3.2
diagModeEntrySpecifies the index for each row in the table below
DiagModeEntry
.1.3.6.1.4.1.4253.3.3.2.1
diagLocationThe location of the card: local or remotero
CardLocation
.1.3.6.1.4.1.4253.3.3.2.1.1
diagShelfThe shelf in which the card is located.ro
CardShelf
.1.3.6.1.4.1.4253.3.3.2.1.2
diagSlotThe card slot in which the card is located.ro
CardSlot
.1.3.6.1.4.1.4253.3.3.2.1.3
diagSetModeIf on, the card will be in diagnostics mode. If off, the card comes out of diagnostics mode.ro
Enumeration
.1.3.6.1.4.1.4253.3.3.2.1.4
diagTestNumNumber of built-in diagnostics tests in the table below.ro
INTEGER
.1.3.6.1.4.1.4253.3.3.3
diagTestTableThis table represents the information for each built-in diagnostics test.
SEQUENCE OF DiagTestEntry
.1.3.6.1.4.1.4253.3.3.4
diagTestEntrySpecifies the index for each row in the table below
DiagTestEntry
.1.3.6.1.4.1.4253.3.3.4.1
diagTestIdThe name of the built-in diagnostics test.rw
Enumeration
.1.3.6.1.4.1.4253.3.3.4.1.1
diagTLocationThe location of the card to run the test onrw
CardLocation
.1.3.6.1.4.1.4253.3.3.4.1.2
diagTShelfThe shelf in which the card is located.rw
CardShelf
.1.3.6.1.4.1.4253.3.3.4.1.3
diagTSlotThe card slot in which the card is located.rw
CardSlot
.1.3.6.1.4.1.4253.3.3.4.1.4
diagParam1The first parameter, if any to pass to the built-in test module. This parameter may be NULL to signify no run-time parameters. If there is a parameter in, any data type, it should be passed as a String equivalent.rw
DisplayString
.1.3.6.1.4.1.4253.3.3.4.1.5
diagParam2The second parameter, if any to pass to the built-in test module. This parameter may be NULL to signify no more run-time parameters. If there is a parameter in any data type, it should be passed as a String equivalent.rw
DisplayString
.1.3.6.1.4.1.4253.3.3.4.1.6
diagParam3The third parameter, if any to pass to the built-in test module. This parameter may be NULL to signify no more run-time parameters. If there is a parameter in any data type, it should be passed as a String equivalent.rw
DisplayString
.1.3.6.1.4.1.4253.3.3.4.1.7
diagTSetModeIf on, the given test will be run on the given card. The value off has no effect in this case and is ignored.rw
FlagType
.1.3.6.1.4.1.4253.3.3.4.1.8
diagSelfTest
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.3.3.5
mcmescSelfTest
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.3.3.5.1
mcmescSelfTestTableThis table represents the self-test results for mcmesc link port.
SEQUENCE OF McmescSelfTestEntry
.1.3.6.1.4.1.4253.3.3.5.1.1
mcmescSelfTestEntrySpecifies the index for each row in the table below
McmescSelfTestEntry
.1.3.6.1.4.1.4253.3.3.5.1.1.1
mcmescSelfTestLocationThe location of the card: local or remote. The self test is applicable to local mcmesc only.ro
CardLocation
.1.3.6.1.4.1.4253.3.3.5.1.1.1.1
mcmescSelfTestShelfThe shelf in which the card is located.ro
CardShelf
.1.3.6.1.4.1.4253.3.3.5.1.1.1.2
mcmescSelfTestSlotThe card slot in which the card is located.ro
CardSlot
.1.3.6.1.4.1.4253.3.3.5.1.1.1.3
mcmescSelfTestStartInitiate a self-test. A get on this will always return an other. Any outstanding loopbacks will be turned off before starting self-test.rw
Enumeration
.1.3.6.1.4.1.4253.3.3.5.1.1.1.4
mcmescSelfTestResultIndicate an overall result of the latest self-test. The value inprogress(3) will be given if a self-test is in progress. The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult show the detail result of each individual test item.ro
Enumeration
.1.3.6.1.4.1.4253.3.3.5.1.1.1.5
mcmescSelfTestSeqNumIndicate a sequece number associated with the latest complete self test. The sring of inprogress will be given if a self-test is in progress. The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult show the detail result of each individual test item.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.3.5.1.1.1.6
mcmescSelfTestTimeStampIndicate the time stamp associated with the latest complete self test. The value inprogress(3) will be given if a self-test is in progress. The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult show the detail result of each individual test item.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.3.5.1.1.1.7
mcmescLinkSelfTestResultTableThis table represents the self-test results for mcmesc link port.
SEQUENCE OF McmescLinkSelfTestResultEntry
.1.3.6.1.4.1.4253.3.3.5.1.2
mcmescLinkSelfTestResultEntrySpecifies the index for each row in the table below
McmescLinkSelfTestResultEntry
.1.3.6.1.4.1.4253.3.3.5.1.2.1
mcmescLinkSelfTestLocationThe location of the card: local or remote. The self test is applicable to local mcmesc only.ro
CardLocation
.1.3.6.1.4.1.4253.3.3.5.1.2.1.1
mcmescLinkSelfTestShelfThe shelf in which the card is located.ro
CardShelf
.1.3.6.1.4.1.4253.3.3.5.1.2.1.2
mcmescLinkSelfTestSlotThe card slot in which the card is located.ro
CardSlot
.1.3.6.1.4.1.4253.3.3.5.1.2.1.3
mcmescLinkSelfTestTxI2cIndicate the link port's Tx I2C self-test result. The value inprogress(3) will be given if a self-test is in progress.ro
Enumeration
.1.3.6.1.4.1.4253.3.3.5.1.2.1.4
mcmescLinkSelfTestCdrI2cIndicate the link port's CDR I2C self-test result. The value inprogress(3) will be given if a self-test is in progress.ro
Enumeration
.1.3.6.1.4.1.4253.3.3.5.1.2.1.5
mcmescLinkSelfTestDataPathIndicate the link port's data path self-test result. The value inprogress(3) will be given if a self-test is in progress.ro
Enumeration
.1.3.6.1.4.1.4253.3.3.5.1.2.1.6
mcmescPortSelfTestResultTableThis table represents the self-test results for mcmesc CPE port.
SEQUENCE OF McmescPortSelfTestResultEntry
.1.3.6.1.4.1.4253.3.3.5.1.3
mcmescPortSelfTestResultEntrySpecifies the index for each row in the table below
McmescPortSelfTestResultEntry
.1.3.6.1.4.1.4253.3.3.5.1.3.1
mcmescPortSelfTestLocationThe location of the card: local or remote. The self test is applicable to local mcmesc only.ro
CardLocation
.1.3.6.1.4.1.4253.3.3.5.1.3.1.1
mcmescPortSelfTestShelfThe shelf in which the card is located.ro
CardShelf
.1.3.6.1.4.1.4253.3.3.5.1.3.1.2
mcmescPortSelfTestSlotThe card slot in which the card is located.ro
CardSlot
.1.3.6.1.4.1.4253.3.3.5.1.3.1.3
mcmescPortSelfTestPortThe CPE port's index.ro
INTEGER
.1.3.6.1.4.1.4253.3.3.5.1.3.1.4
mcmescPortSelfTestTxI2cIndicate the CPE port's Tx I2C self-test result. The value inprogress(3) will be given if a self-test is in progress.ro
Enumeration
.1.3.6.1.4.1.4253.3.3.5.1.3.1.5
mcmescPortSelfTestCdrI2cIndicate the CPE port's CDR I2C self-test result. The value inprogress(3) will be given if a self-test is in progress.ro
Enumeration
.1.3.6.1.4.1.4253.3.3.5.1.3.1.6
mcmescPortSelfTestTxDataPathIndicate the CPE port's Tx data path self-test result. The value inprogress(3) will be given if a self-test is in progress.ro
Enumeration
.1.3.6.1.4.1.4253.3.3.5.1.3.1.7
mcmescPortSelfTestRxDataPathIndicate the CPE port's Rx data path self-test result. The value inprogress(3) will be given if a self-test is in progress.ro
Enumeration
.1.3.6.1.4.1.4253.3.3.5.1.3.1.8
alarmLog
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.3.4
alarmNumEventsNumber of alarms logged in the table below. This counter is automatically set by the software. The max is 300 entries.ro
INTEGER
.1.3.6.1.4.1.4253.3.4.1
alarmLogTableThis table represents the information for the alarm log buffer
SEQUENCE OF AlarmLogEntry
.1.3.6.1.4.1.4253.3.4.2
alarmLogEntrySpecifies the index for each row in the table below
AlarmLogEntry
.1.3.6.1.4.1.4253.3.4.2.1
alarmFirstDateTimeThe date and time for the first alarm occurrence.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.4.2.1.1
alarmTagA unique tag used to identify the alarm entry.ro
INTEGER
.1.3.6.1.4.1.4253.3.4.2.1.2
alarmLastDateTimeThe date and time for the most recent alarm occurrence. If this is the first time occurrence, it would be same as alarmFirstDateTime.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.3.4.2.1.3
alarmEventIdThe event ID assigned to this alarm.ro
INTEGER
.1.3.6.1.4.1.4253.3.4.2.1.4
alarmSeverityThe severity of this alarm. Could be critical, major, or minor.ro
Enumeration
.1.3.6.1.4.1.4253.3.4.2.1.5
alarmSourceA five to seven tuple string composed of the following items: System Name:card type (MPM, OCMITU, OFCM, etc.). location (L for local, R[number] for remote with optional station number). shelf #. slot id[. port #][:link name(optional depending on card type)][:ring name (optional)] [:pathname(optional)]. When an event applies to all slots of the whole chassis, 0 will be displayed for both shelf and slot. Example: SystemInSunnyvale:OCMITU.L.1.6:ITU23ro
DisplayString
.1.3.6.1.4.1.4253.3.4.2.1.6
alarmDescrA string signifying the cause of the error in natural language (preferrably English) format.ro
DisplayString
.1.3.6.1.4.1.4253.3.4.2.1.7
alarmCntNumber of times alarm has occurred(from the same source).ro
INTEGER
.1.3.6.1.4.1.4253.3.4.2.1.8
alarmAckAcknowledge or unacknowledge the active alarm. Ack will remove its contribution to the external dry contact alarm closure. Default is unacknowledged.rw
Enumeration
.1.3.6.1.4.1.4253.3.4.2.1.9
alarmClearAn action to clear the alarm from the alarm log. If alarm persists, another alarm will be sent. A GET operation would always return other(1).rw
Enumeration
.1.3.6.1.4.1.4253.3.4.2.1.10
alarmLastChangeTime ticks in microseconds of when the last change was made to the alarm log. This includes ack/unack, clear, and alarm addition/deletion.ro
INTEGER
.1.3.6.1.4.1.4253.3.4.3
security
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.4
userSecMgmt
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.4.1
usrNumUsersNumber of user Logons in the table below. This counter is automatically set by the software.ro
INTEGER
.1.3.6.1.4.1.4253.4.1.1
usrSecTableThis table represents the information for each user logon entry.
SEQUENCE OF UsrSecEntry
.1.3.6.1.4.1.4253.4.1.2
usrSecEntrySpecifies the index for each row in the table below
UsrSecEntry
.1.3.6.1.4.1.4253.4.1.2.1
usrSecLogonIdThe unique logon ID assigned to each user. This field should only be written by users that are in the right security role.rw
LogonID
.1.3.6.1.4.1.4253.4.1.2.1.1
usrSecPasswdThe hashed password for each unique logon ID. To turn the user account off, typically the password is set to some fixed value. Fixed passwords are not accepted as valid passwords. Since this field is one-way hashed, it can be safely read without compromising the security of the system.rw
HashedPasswd
.1.3.6.1.4.1.4253.4.1.2.1.2
usrSecRoleThe role associated with each user logon ID. This is an index into the system role(s) table.rw
INTEGER
.1.3.6.1.4.1.4253.4.1.2.1.3
usrSecFullNameThe full name of the user associated with each unique logon ID.rw
DisplayString
.1.3.6.1.4.1.4253.4.1.2.1.4
usrSecActDateTimeThe Time & Date of the user account activation.ro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.4.1.2.1.5
usrSecLastDateTimeThe Time & Date of the last user logon to the systemro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4253.4.1.2.1.6
usrSecSetLastDateTimeAn action to set the Time & Date of the last user logon to the current systemtime.rw
ResetType
.1.3.6.1.4.1.4253.4.1.2.1.7
systemSecMgmt
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.4.2
secNumRolesNumber of system security roles in the table below. This counter is automatically set by the software.
INTEGER
.1.3.6.1.4.1.4253.4.2.1
secRoleTableThis table represents the information for each system security role entry.
SEQUENCE OF SecRoleEntry
.1.3.6.1.4.1.4253.4.2.2
secRoleEntrySpecifies the index for each row in the table below
SecRoleEntry
.1.3.6.1.4.1.4253.4.2.2.1
secRoleEach row in this table defines a unique security role.
EntityName
.1.3.6.1.4.1.4253.4.2.2.1.1
secRoleDescrThe full narrated description of each security Role.
DisplayString
.1.3.6.1.4.1.4253.4.2.2.1.2
secNumGroupsNumber of entity groups in the table below. This counter is automatically set by the software.
INTEGER
.1.3.6.1.4.1.4253.4.2.3
secGroupTableThis table represents the information for each entity group entry.
SEQUENCE OF SecGroupEntry
.1.3.6.1.4.1.4253.4.2.4
secGroupEntrySpecifies the index for each row in the table below
SecGroupEntry
.1.3.6.1.4.1.4253.4.2.4.1
secGroupEach row in this table defines a grouping of entities or elements from the MIB.
EntityName
.1.3.6.1.4.1.4253.4.2.4.1.1
secGroupRoleThe containment of this group within a security role. Under the given schema, each Role may have zero or more entity groups. Given an entity group, it may have been contained within one or more roles.
EntityName
.1.3.6.1.4.1.4253.4.2.4.1.2
secNumElementsNumber of elements or entities in the table below. This counter is automatically set by the software.
INTEGER
.1.3.6.1.4.1.4253.4.2.5
secElementTableThis table represents the information for each entity or element in the MIB.
SEQUENCE OF SecElementEntry
.1.3.6.1.4.1.4253.4.2.6
secElementEntrySpecifies the index for each row in the table below
SecElementEntry
.1.3.6.1.4.1.4253.4.2.6.1
secElementEach row in this table defines an element or entity from the MIB.
EntityName
.1.3.6.1.4.1.4253.4.2.6.1.1
secElementAccessThe original access mode for this element from the MIB.
Enumeration
.1.3.6.1.4.1.4253.4.2.6.1.2
secElementOIDThe original SNMP OID for this element from the MIB.
DisplayString
.1.3.6.1.4.1.4253.4.2.6.1.3
secElementTypeThe original type for this element from the MIB.
Enumeration
.1.3.6.1.4.1.4253.4.2.6.1.4
secElementParentThe original parent name for this element from the MIB. The parent is either a table or a subgroup.
EntityName
.1.3.6.1.4.1.4253.4.2.6.1.5
secNumElmntGrpNumber of element-to-group mappings in the table below. This counter is automatically set by the software.
INTEGER
.1.3.6.1.4.1.4253.4.2.7
secElmntGrpTableThis table represents the information for each element-to-group mapping.
SEQUENCE OF SecElmntGrpEntry
.1.3.6.1.4.1.4253.4.2.8
secElmntGrpEntrySpecifies the index for each row in the table below
SecElmntGrpEntry
.1.3.6.1.4.1.4253.4.2.8.1
elmntNameEach row in this table defines a mapping of elements to groups. This column is an index into the secElementTable.
EntityName
.1.3.6.1.4.1.4253.4.2.8.1.1
grpNameEach row in this table defines a mapping of elements to groups. This column is an index into the secGroupTable.
EntityName
.1.3.6.1.4.1.4253.4.2.8.1.2
elmntGrpAccessThe access mode assigned to each element/group entry. Under the given schema, each group may have zero or more MIB elements. Given an element, it may have been contained within one or more groups. The access mode specified here defines what is the granted access mode to the named element contained in this group. Note, the granted access right can never exceed that of the actual MIB access privilege.
Enumeration
.1.3.6.1.4.1.4253.4.2.8.1.3
netSecMgmt
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.4.3
radiusSecMgmt
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.4.3.1
radiusAuthOrderThe authentication order used when validating a user login id and password.rw
Enumeration
.1.3.6.1.4.1.4253.4.3.1.1
radiusNasIdentifierNAS-Identifier for the MPM.rw
DisplayString
.1.3.6.1.4.1.4253.4.3.1.2
radiusDefaultRealmDefault realm used for radius authentication. This realm is not used for local authentication.rw
DisplayString
.1.3.6.1.4.1.4253.4.3.1.3
radiusTimeoutTimeout when sending an authentication request to a radius server.rw
INTEGER
.1.3.6.1.4.1.4253.4.3.1.4
radiusRetriesNumber of times to resend requests when a timeout occurs.rw
INTEGER
.1.3.6.1.4.1.4253.4.3.1.5
radiusSecTableRadius server table.
SEQUENCE OF RadiusSecEntry
.1.3.6.1.4.1.4253.4.3.1.6
radiusSecEntrySpecifies the index for each row in the table below
RadiusSecEntry
.1.3.6.1.4.1.4253.4.3.1.6.1
radiusServerIndexIndex into the radius server table. This index also specifies the server order used for sending authentication requests.ro
INTEGER
.1.3.6.1.4.1.4253.4.3.1.6.1.1
radiusServerAddressIP address of the radius server. Setting the address to 0 will delete the server entry.rw
IpAddress
.1.3.6.1.4.1.4253.4.3.1.6.1.2
radiusServerPortRadius port used for authentication requests.rw
INTEGER
.1.3.6.1.4.1.4253.4.3.1.6.1.3
radiusServerSecretSecret shared with authentication server.rw
DisplayString
.1.3.6.1.4.1.4253.4.3.1.6.1.4
radiusAddServerAdd server to the server table. Servers are added to the first available entry in the server table. To add a server provide server IP address, radius port, and shared secret in the format '<ip address>,<port>, <secret>'. All fields are required. a get on this element will return '0,0,0'.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4253.4.3.1.7
sshSecMgmt
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.4.3.2
sshModeEnables or disables the SSH server. Enabling SSH will disable the built in telnet server. Disabling SSH will enable the telnet server.rw
Enumeration
.1.3.6.1.4.1.4253.4.3.2.1
sshKeySizeThe size (in bits) of the DSS key to generate. Key size must be a multiple of 8 and between 512 and 1024 bits.rw
INTEGER
.1.3.6.1.4.1.4253.4.3.2.2
sshMaxSessionsThe maximum number of SSH sessions that can be active at one time. Setting this element will also affect the number of telnet sessions that can be active at a time.rw
INTEGER
.1.3.6.1.4.1.4253.4.3.2.3
sshGenKeySetting this element to genDssKey(2) will cause a new DSS key to be generated. The process of generating a new key can take some time (several minutes) and may cause significant system slowdown until the process is complete. Reading this element will always return other(1).rw
Enumeration
.1.3.6.1.4.1.4253.4.3.2.4
accounting
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.5
cpAcct
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.5.1
acctCPTableThis table represents the information for each system accounting data maintained for each CP.
SEQUENCE OF AcctCPEntry
.1.3.6.1.4.1.4253.5.1.1
acctCPEntrySpecifies the index for each row in the table below
AcctCPEntry
.1.3.6.1.4.1.4253.5.1.1.1
acctCPShelfThe shelf in which the given CP card is placed.ro
CardShelf
.1.3.6.1.4.1.4253.5.1.1.1.1
acctCPSlotThe slot in which the given CP card is placed.ro
CardSlot
.1.3.6.1.4.1.4253.5.1.1.1.2
acctCPDsgnActThe total time this CP has been designated Active
Counter
.1.3.6.1.4.1.4253.5.1.1.1.3
acctCPDsgnStdbyThe total time this CP has been designated Standby
Counter
.1.3.6.1.4.1.4253.5.1.1.1.4
acctCPActiveThe total time this CP has actually been the primaryro
Counter
.1.3.6.1.4.1.4253.5.1.1.1.5
acctCPStandbyThe total time this CP has actually been the standbyro
Counter
.1.3.6.1.4.1.4253.5.1.1.1.6
acctCPUpTimeThe total time since this CP has been commissionedro
Counter
.1.3.6.1.4.1.4253.5.1.1.1.7
acctCPUnAvailThe total time this CP has not been available due to an alarm, diag testing or being put offlinero
Counter
.1.3.6.1.4.1.4253.5.1.1.1.8
acctCPResetCntrsIf reset, the CP accounting counters will be reset to 0. A get on this will always return other.rw
ResetType
.1.3.6.1.4.1.4253.5.1.1.1.9
ccAcct
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.5.2
acctCCTableThis table represents the information for each system accounting data maintained for each CC.
SEQUENCE OF AcctCCEntry
.1.3.6.1.4.1.4253.5.2.1
acctCCEntrySpecifies the index for each row in the table below
AcctCCEntry
.1.3.6.1.4.1.4253.5.2.1.1
acctCCLocationThe location of the CC card: local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.5.2.1.1.1
acctCCShelfThe shelf in which the given CC card is placed.ro
CardShelf
.1.3.6.1.4.1.4253.5.2.1.1.2
acctCCSlotThe slot in which the given CC card is placed.ro
CardSlot
.1.3.6.1.4.1.4253.5.2.1.1.3
acctCCUpTimeThe total time since this CC has been commissionedro
Counter
.1.3.6.1.4.1.4253.5.2.1.1.4
acctCCUnAvailThe total time this CC has not been available due to an alarm, diag testing or being put offlinero
Counter
.1.3.6.1.4.1.4253.5.2.1.1.5
acctCCResetCntrsIf reset, the CC accounting counters will be reset to 0. A get on this will always return other.rw
ResetType
.1.3.6.1.4.1.4253.5.2.1.1.6
mcmAcct
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.5.3
acctmcmTableThis table represents the information for each system accounting data maintained for each MCMT1/MCME1.
SEQUENCE OF AcctmcmEntry
.1.3.6.1.4.1.4253.5.3.1
acctmcmEntrySpecifies the index for each row in the table below
AcctmcmEntry
.1.3.6.1.4.1.4253.5.3.1.1
acctmcmLocationThe location of the MCMT1/MCME1 card: local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.5.3.1.1.1
acctmcmShelfThe shelf in which the given MCMT1/MCME1 card is placed.ro
CardShelf
.1.3.6.1.4.1.4253.5.3.1.1.2
acctmcmSlotThe slot in which the given MCMT1/MCME1 card is placed.ro
CardSlot
.1.3.6.1.4.1.4253.5.3.1.1.3
acctmcmUpTimeThe total time since this MCMT1/MCME1 has been commissionedro
Counter
.1.3.6.1.4.1.4253.5.3.1.1.4
acctmcmUnAvailThe total time this MCMT1/MCME1 has not been available due to an alarm, diag testing or being put offlinero
Counter
.1.3.6.1.4.1.4253.5.3.1.1.5
acctmcmResetCntrsIf reset, the MCMT1/MCME1 accounting counters will be reset to 0. A get on this will always return other.rw
ResetType
.1.3.6.1.4.1.4253.5.3.1.1.6
mcmescAcct
OBJECT IDENTIFIER
.1.3.6.1.4.1.4253.5.4
acctmcmescTableThis table represents the information for each system accounting data maintained for each MCMESC.
SEQUENCE OF AcctmcmescEntry
.1.3.6.1.4.1.4253.5.4.1
acctmcmescEntrySpecifies the index for each row in the table below
AcctmcmescEntry
.1.3.6.1.4.1.4253.5.4.1.1
acctmcmescLocationThe location of the MCMESC card: local or remote.ro
CardLocation
.1.3.6.1.4.1.4253.5.4.1.1.1
acctmcmescShelfThe shelf in which the given MCMESC card is placed.ro
CardShelf
.1.3.6.1.4.1.4253.5.4.1.1.2
acctmcmescSlotThe slot in which the given MCMESC card is placed.ro
CardSlot
.1.3.6.1.4.1.4253.5.4.1.1.3
acctmcmescUpTimeThe total time since this MCMESC has been commissioned.ro
Counter
.1.3.6.1.4.1.4253.5.4.1.1.4
acctmcmescUnAvailThe total time this MCMESC has not been available due to an alarm, diag testing or being put offline.ro
Counter
.1.3.6.1.4.1.4253.5.4.1.1.5
acctmcmescResetCntrsIf reset, the MCMESC accounting counters will be reset to 0. A get on this will always return other.ro
ResetType
.1.3.6.1.4.1.4253.5.4.1.1.6