Home/Catalog/ARRIS-C3-FPD-MIB

ARRIS-C3-FPD-MIB

AI MIB Summary

The ARRIS-C3-FPD-MIB facilitates SNMP-based monitoring and configuration of the Front Panel Display subsystem on Arris CMTS C3 hardware, specifically managing display state, content rendering, and operational status indicators for the device's physical interface.

This MIB manages the Front Panel Display (FPD) software on the Arris CMTS C3
Main OID:
cmtsC3FPDMIB.1.3.6.1.4.1.4115.1.4.3.3
54
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

54 total
Object Name
cmtsC3FPDMIBThis MIB manages the Front Panel Display (FPD) software on the Arris CMTS C3
MODULE-IDENTITY
.1.3.6.1.4.1.4115.1.4.3.3
dcxFPDObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.4115.1.4.3.3.1
dcxFPDMsgTableTable of Front Panel LCD Messages.
SEQUENCE OF DcxFPDMsgEntry
.1.3.6.1.4.1.4115.1.4.3.3.1.1
dcxFPDMsgEntry.
DcxFPDMsgEntry
.1.3.6.1.4.1.4115.1.4.3.3.1.1.1
dcxFPDMsgIndexIndex used to order the FPD Messages.
Unsigned32
.1.3.6.1.4.1.4115.1.4.3.3.1.1.1.1
dcxFPDMsgStringSpecifies a string that can be displayed on the front panel.rw
OCTET STRING
.1.3.6.1.4.1.4115.1.4.3.3.1.1.1.2
dcxFPDControlGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.4115.1.4.3.3.1.2
dcxFPDAttachedStatusDisplays if the front panel display is attached to the Cmts or not.ro
Enumeration
.1.3.6.1.4.1.4115.1.4.3.3.1.2.1
dcxFPDPowerStatus1Specifies if the primary power supply is working. This is the rightmost power supply. The following values are possible: on(1) and off(2)ro
Enumeration
.1.3.6.1.4.1.4115.1.4.3.3.1.2.2
dcxFPDPowerStatus2Specifies if the secondary power supply is working. This is the leftmost power supply(nearest the fan tray). The following values are possible: on(1) and off(2)ro
Enumeration
.1.3.6.1.4.1.4115.1.4.3.3.1.2.3
dcxFPDTemp1StatusSpecifies the temperature reading for the sensor on the CPU card closest to the CPU.ro
Integer32
.1.3.6.1.4.1.4115.1.4.3.3.1.2.4
dcxFPDTemp2StatusSpecifies the temperature reading for the sensor on the CPU card, on the right hand side.ro
Integer32
.1.3.6.1.4.1.4115.1.4.3.3.1.2.5
dcxFPDTemp3StatusSpecifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX4 and RX5.ro
Integer32
.1.3.6.1.4.1.4115.1.4.3.3.1.2.6
dcxFPDTemp4StatusSpecifies the temperature reading for the sensor on the Kanga card under the Roo cards between RX2 and RX3.ro
Integer32
.1.3.6.1.4.1.4115.1.4.3.3.1.2.7
dcxFPDFan1StatusSpecifies the fan status for the fan nearest the front of the box. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.ro
Enumeration
.1.3.6.1.4.1.4115.1.4.3.3.1.2.8
dcxFPDFan2StatusSpecifies the fan status for the fan 2nd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.ro
Enumeration
.1.3.6.1.4.1.4115.1.4.3.3.1.2.9
dcxFPDFan3StatusSpecifies the fan status for the fan 3rd from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.ro
Enumeration
.1.3.6.1.4.1.4115.1.4.3.3.1.2.10
dcxFPDFan4StatusSpecifies the fan status for the fan 4th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.ro
Enumeration
.1.3.6.1.4.1.4115.1.4.3.3.1.2.11
dcxFPDFan5StatusSpecifies the fan status for the fan 5th from the front. The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.ro
Enumeration
.1.3.6.1.4.1.4115.1.4.3.3.1.2.12
dcxFPDFan6StatusSpecifies the fan status for the fan nearest the back of the box The following values are possible: Rotating(1) and BadRotating(2). BadRotating is set when the fan is operating outside of dcxFPDFanUpperLimit and dcxFPDFanLowerLimit.ro
Enumeration
.1.3.6.1.4.1.4115.1.4.3.3.1.2.13
dcxFPDFanUpperLimitSpecifies the upper fan limit(Upper threshold of expected current draw)rw
Integer32
.1.3.6.1.4.1.4115.1.4.3.3.1.2.14
dcxFPDFanLowerLimitSpecifies the lower fan limit(Lower threshold of expected current draw)rw
Integer32
.1.3.6.1.4.1.4115.1.4.3.3.1.2.15
dcxFPDLCDContrastSpecifies the contrast level for the LCDrw
Integer32
.1.3.6.1.4.1.4115.1.4.3.3.1.2.16
dcxFPDLedSetStatusUsed to turn on or off a Led on the front panelrw
Integer32
.1.3.6.1.4.1.4115.1.4.3.3.1.2.17
dcxFPDHwRevisionSpecifies the front panel h/w revisionro
Integer32
.1.3.6.1.4.1.4115.1.4.3.3.1.2.18
dcxFPDSwRevisionSpecifies the front panel s/w revisionro
Integer32
.1.3.6.1.4.1.4115.1.4.3.3.1.2.19
dcxFPDTrapGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.4115.1.4.3.3.1.3
dcxFPDAttachedFront Panel Display has been attached.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.1
dcxFPDDetachedFront Panel Display has been detached.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.2
dcxFPDFan1FailFan nearest the front of the box failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.3
dcxFPDFan1FailClrFan nearest the front of the box is working
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.4
dcxFPDFan2FailFan 2nd from the front failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.5
dcxFPDFan2FailClrFan 2nd from the front is working
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.6
dcxFPDFan3FailFan 3rd from the front failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.7
dcxFPDFan3FailClrFan 3rd from the front is working
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.8
dcxFPDFan4FailFan 4th from the front failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.9
dcxFPDFan4FailClrFan 4th from the front is working
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.10
dcxFPDFan5FailFan 5th from the front failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.11
dcxFPDFan5FailClrFan 5th from the front is working
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.12
dcxFPDFan6FailFan nearest the back of the box failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.13
dcxFPDFan6FailClrFan nearest the back of the box is working
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.14
dcxFPDPwr1FailRightmost power supply failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.15
dcxFPDPwr1FailClrRightmost power supply is working
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.16
dcxFPDPwr2FailLeftmost power supply failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.17
dcxFPDPwr2FailClrLeftmost power supply is working
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.18
dcxFPDTempOkaySystem temperature is OK
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.19
dcxFPDTempBadSystem temperature is too hot!
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.20
dcxFPDTempCriticalSystem temperature is critical!!!, CMTS will shut itself down!!!!
NOTIFICATION-TYPE
.1.3.6.1.4.1.4115.1.4.3.3.1.3.21
dcxFPDConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.4115.1.4.3.3.1.4
dcxFPDCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.4115.1.4.3.3.1.4.1
dcxFPDComplianceThe compliance statement for devices that implement Arris C3 compliant FPD features
Unknown
.1.3.6.1.4.1.4115.1.4.3.3.1.4.1.1
dcxFPDGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.4115.1.4.3.3.1.4.2
dcxFPDMsgGroupArris C3 FPD message group
Unknown
.1.3.6.1.4.1.4115.1.4.3.3.1.4.2.1
dcxFPDControlConfGroupArris C3 FPD Control group
Unknown
.1.3.6.1.4.1.4115.1.4.3.3.1.4.2.2
ARRIS-C3-FPD-MIB - SNMP MIB Reference | MIBs Explorer