Home/Catalog/ALPHA-NOTIFICATION-MIB

ALPHA-NOTIFICATION-MIB

AI MIB Summary

The ALPHA-NOTIFICATION-MIB defines the standardized trap and inform message structures for system controllers, enabling the transmission of critical operational events and fault conditions to an SNMP management station. This module facilitates real-time alerting on device status changes, hardware failures, or configuration anomalies without requiring active polling.

This MIB defines the notification block(s) available in system controllers.
Main OID:
alphaAlarmNotifications.1.3.6.1.4.1.7309.100
10
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

10 total
Object Name
alphaAlarmNotificationsThis MIB defines the notification block(s) available in system controllers.
MODULE-IDENTITY
.1.3.6.1.4.1.7309.100
alphaAlarmActiveStateSNMPv2 notification varbinds start with SysUptime and Notification Oid as the first two in the list by default. The first varbind in this definition would be the third varbind in the raw output of the notification. An instance of the alarm indicated by alarmActiveModelPointer has been raised against the entity indicated by alarmActiveResourceId. The state of the alarm is indicated by the alarmModelState. The description of the alarm along with its source is indicated by the alarmModelDescription and componentListStaticName respectively. componentListSnmpId provides the Id set to the source of the alarm. The agent must throttle the generation of consecutive alarmActiveState traps so that there is at least a two-second gap between traps of this type against the same alarmActiveModelPointer and alarmActiveResourceId. When traps are throttled, they are queued for sending at a future time. A management application should periodically check the value of alarmActiveLastChanged to detect any missed alarmActiveState notification-events, e.g., due to throttling or transmission loss.
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.100.1
alphaAlarmClearStateSNMPv2 notification varbinds start with SysUptime and Notification Oid as the first two in the list by default. The first varbind in this definition would be the third varbind in the raw output of the notification. An instance of the alarm indicated by alarmActiveModelPointer has been cleared against the entity indicated by alarmActiveResourceId. The state of the alarm is indicated by the alarmModelState. The description of the alarm along with its source is indicated by the alarmModelDescription and componentListStaticName respectively. componentListSnmpId provides the Id set to the source of the alarm. The agent must throttle the generation of consecutive alarmActiveClear traps so that there is at least a two-second gap between traps of this type against the same alarmActiveModelPointer and alarmActiveResourceId. When traps are throttled, they are queued for sending at a future time. A management application should periodically check the value of alarmActiveLastChanged to detect any missed alarmClearState notification-events, e.g., due to throttling or transmission loss.
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.100.2
alphaAlarmNotificationConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.100.102
alphaAlarmNotificationCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.100.102.1
alphaAlarmNotificationGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.100.102.1.2
alphaAlarmNotificationsExtension
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.101
alarmSeverityUser defined value used for filtering purposes.ro
Integer32
.1.3.6.1.4.1.7309.101.1
alarmCustomDescriptionUser defined value used for filtering purposes.ro
OCTET STRING
.1.3.6.1.4.1.7309.101.2
alarmPriorityUser defined value used for filtering purposes.ro
OCTET STRING
.1.3.6.1.4.1.7309.101.3

More MIBs from Alpha

Browse all AlphaMIBs →
SITE-MONITORING-MIB

The SITE-MONITORING-MIB structures SNMP OIDs to categorize and organize management data for Alpha Innovations hardware based on specific design center architectures. This module facilitates the monitoring of site-specific operational metrics and device states within the vendor's proprietary network infrastructure.

552 objects→
AlphaPowerSystem-MIB

AlphaPowerSystem-MIB facilitates SNMP monitoring of DC power system devices within Cordex series controllers, specifically exposing the `dcPwrSysDevice` information block for tracking power subsystem status and operational parameters.

226 objects→
Argus-MIB

The Argus-MIB facilitates SNMP monitoring of SM-series system controllers, specifically exposing the `dcPwrSysDevice` information block to track DC power system status and device health metrics.

217 objects→
Inverter-MIB

SNMP MIB module

133 objects→
ALPHA-RESOURCE-MIB

The ALPHA-RESOURCE-MIB provides standardized SNMP access to hardware resource utilization metrics, such as CPU load, memory consumption, and storage capacity, within system controllers. This module enables network management systems to monitor critical performance thresholds and capacity planning data for ALPHA vendor infrastructure.

94 objects→
Argus-Power-System-MIB

The Argus-Power-System-MIB facilitates SNMP monitoring of CXC-series RMU controllers, specifically exposing the `upsDevice` information block to track Uninterruptible Power Supply (UPS) status, battery conditions, and power system health metrics.

83 objects→