Home/Catalog/ADTRAN-ATLAS-550-MIB

ADTRAN-ATLAS-550-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ADTRAN-ATLAS-550-MIB.

28
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

28 total
Object Name
adtran
OBJECT IDENTIFIER
.1.3.6.1.4.1.664
RFC1155-SMI
Unknown
.1.3.6.1.4.1.664
adMgmt
OBJECT IDENTIFIER
.1.3.6.1.4.1.664.2
adATLAS550mg
OBJECT IDENTIFIER
.1.3.6.1.4.1.664.2.219
adATLAS550ExtAlarmActiveThis trap indicates that an external alarm has been activated via the short circuiting of pins on the RELAY MON connector located on the rear panel of the Atlas 550.
TRAP-TYPE
.1.3.6.1.4.1.664.2.219.0.21900
adATLAS550ExtAlarmInactiveThis trap indicates that an external alarm has been deactivated via the open circuiting of pins on the RELAY MON connector located on the rear panel of the Atlas 550.
TRAP-TYPE
.1.3.6.1.4.1.664.2.219.0.21901
adATLAS550Fpnl
OBJECT IDENTIFIER
.1.3.6.1.4.1.664.2.219.1
adATLAS550FpnlSysLeds
OBJECT IDENTIFIER
.1.3.6.1.4.1.664.2.219.1.1
adATLAS550FpnlPowThis variable indicates if the unit is powererd on or off. The various Power LED states are: Number State Status 1 ON GREEN 2 OFF OFFro
Enumeration
.1.3.6.1.4.1.664.2.219.1.1.1
adATLAS550FpnlSysThis variable indicates the status of the System LED. When the System LED changes state, this variable also changes state. The various system LED states are: Number State Status 1 OK Green 2 Error Red 3 Warning Yellow 4 Flash Update Green Fast 5 Flash Error Red Fast 6 Off Off 7 Green Slow Green Slow 8 Yellow Slow Yellow Slow 9 Yellow Fast Yellow Fast 10 Red Slow Red Slowro
Enumeration
.1.3.6.1.4.1.664.2.219.1.1.2
adATLAS550FpnlEthThis variable indicates if the ethernet module is active. If the unit is not recieving data through a valid ethernet connection, the LED is on. If data is being recieved the LED will occasionally flash. If no ethernet connection is established the LED is off. The various Ethernet LED states are: Number State Status 1 ON GREEN 2 OFF OFF 3 Data is passing Green Slow 3 Green Fast Green Fastro
Enumeration
.1.3.6.1.4.1.664.2.219.1.1.3
adATLAS550FpnlRemThis variable indicates if someone is connected to the Atlas 550 using a telnet session. The various Remote LED states are: Number State Status 1 ON YELLOW 2 OFF OFF 3 Flash Slow Yellow Slow 4 Flash Fast Yellow Fastro
Enumeration
.1.3.6.1.4.1.664.2.219.1.1.4
adATLAS550FpnlNtwkLeds
OBJECT IDENTIFIER
.1.3.6.1.4.1.664.2.219.1.2
adATLAS550FpnlNwTableThe Network LED table.
SEQUENCE OF AdATLAS550FpnlNwEntry
.1.3.6.1.4.1.664.2.219.1.2.1
adATLAS550FpnlNwEntryAn entry in the Network Led table.
AdATLAS550FpnlNwEntry
.1.3.6.1.4.1.664.2.219.1.2.1.1
adATLAS550FpnlNwIndexThis variable indicates which network slots are active on the ATLAS 550.ro
INTEGER
.1.3.6.1.4.1.664.2.219.1.2.1.1.1
adATLAS550FpnlNwOKThis variable indicates the status of the network inteface. The choices for this variable are Number State Status 1 OK Green 2 Flash slow Flash Green Slow 3 Flash Fast Flash green fast 4 OFF OFFro
Enumeration
.1.3.6.1.4.1.664.2.219.1.2.1.1.2
adATLAS550FpnlNwTestThis variable indicates if a loopback, test pattern, or self-test is running on the network inteface. The choices for this variable are Number State Status 1 ON Yellow 2 Flash SLOW Flash yellow slow 3 Flash Fast Flash yellow fast 4 OFF OFFro
Enumeration
.1.3.6.1.4.1.664.2.219.1.2.1.1.3
adATLAS550FpnlNwErrorThis variable indicates an alarm condition has been detected on the network inteface. The choices for this variable are Number State Status 1 Error Red 2 Flash Slow Flash Red Slow 3 Flash Fast Flash Red Fast 3 No error OFFro
Enumeration
.1.3.6.1.4.1.664.2.219.1.2.1.1.4
adATLAS550FpnlNwAlarmThis variable indicates an alarm condition has been detected on the network inteface. The choices for this variable are Number State Status 1 Alarm RED 2 Flash Slow Flash Red Slow 3 Flash Fast Flash Red Fast 4 no Alarms OFFro
Enumeration
.1.3.6.1.4.1.664.2.219.1.2.1.1.5
adATLAS550FpnlModLeds
OBJECT IDENTIFIER
.1.3.6.1.4.1.664.2.219.1.3
adATLAS550FpnlModNumberThis variable indicates the number of module slots that are located on the Atlas Product.ro
INTEGER
.1.3.6.1.4.1.664.2.219.1.3.1
adATLAS550FpnlMLTableThe Module LED Table.
SEQUENCE OF AdATLAS550FpnlMLEntry
.1.3.6.1.4.1.664.2.219.1.3.2
adATLAS550FpnlMLEntryAn entry in the Module LED Table.
AdATLAS550FpnlMLEntry
.1.3.6.1.4.1.664.2.219.1.3.2.1
adATLAS550FpnlMLIndexThis variable indicates the available slots.ro
INTEGER
.1.3.6.1.4.1.664.2.219.1.3.2.1.1
adATLAS550FpnlMLStatusThis variable indicates the status of the card located in the slot determined by the MLIndex variable. The choices for this variable are Number State Status 1 OK Green 2 Warn Yellow 3 Error Red 4 One module is offline or invalid flash Flash Slow Green 5 Both modules are offline or invalid flah Flash Fast Green 6 Flash Slow Yellow Flash Slow Yellow 7 Flash Fast Yellow Flash Fast Yellow 8 One module is not ready Flash Slow Red 9 One module has not response Flash Fast Red 10 Off Offro
Enumeration
.1.3.6.1.4.1.664.2.219.1.3.2.1.2
adATLAS550FpnlMLOnlineThis variable indicates whether the card located in the slot determined by the MLIndex is online or offline. The choices for this variable are Number State Status 1 Online Green 2 Invalid flash memory Flashing Slow Green 3 only one module has active connection Flashing fast Green 4 Offline Offro
Enumeration
.1.3.6.1.4.1.664.2.219.1.3.2.1.3
adATLAS550FpnlMLTestThis variable indicates whether the card located in the slot determined by the MLIndex is in a test mode or not. The choices for this variable are Number State Status 1 Test in Progress Yellow 2 Flashing Flashing Yellow 3 Off Offro
Enumeration
.1.3.6.1.4.1.664.2.219.1.3.2.1.4
ADTRAN-ATLAS-550-MIB - SNMP MIB Reference | MIBs Explorer