Home/Catalog/ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB

ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB

AI MIB Summary

The ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB monitors thermal sensor thresholds and generates SNMP traps to alert on over-temperature conditions within AdtranOS-based networking hardware. It facilitates the configuration of temperature limits and the automated notification of thermal events to prevent hardware damage or service interruption.

The MIB module defines over-temperature configuration information and traps for AdtranOS products.
Main OID:
adGenAOSOverTempProtectionMib.1.3.6.1.4.1.664.6.10000.53.1.10
12
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

12 total
Object Name
adGenAOSOverTempProtection
OBJECT IDENTIFIER
.1.3.6.1.4.1.664.5.53.1.10
adGenAOSOverTempProtectionTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.664.5.53.1.10.0
adGenAOSOverTempProtectionWarning
NOTIFICATION-TYPE
.1.3.6.1.4.1.664.5.53.1.10.0.1
adGenAOSOverTempProtectionShutdown
NOTIFICATION-TYPE
.1.3.6.1.4.1.664.5.53.1.10.0.2
adGenAOSOverTempProtectionWarningResume
NOTIFICATION-TYPE
.1.3.6.1.4.1.664.5.53.1.10.0.3
adGenAOSOverTempProtectionShutdownResume
NOTIFICATION-TYPE
.1.3.6.1.4.1.664.5.53.1.10.0.4
adGenAOSOverTempProtectionConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.664.5.53.99.19
adGenAOSOverTempProtectionGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.664.5.53.99.19.1
adGenAOSOverTempProtectionNotificationGroup
Unknown
.1.3.6.1.4.1.664.5.53.99.19.1.1
adGenAOSOverTempProtectionCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.664.5.53.99.19.2
adGenAOSOverTempProtectionFullCompliance
Unknown
.1.3.6.1.4.1.664.5.53.99.19.2.1
adGenAOSOverTempProtectionMib
MODULE-IDENTITY
.1.3.6.1.4.1.664.6.10000.53.1.10

ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB Technical Reference Overview

The ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB SNMP MIB module published by Adtran defines 12 managed OID objects, including 2 scalar/column metrics, 0 SNMP tables, and 4 trap/notification events anchored at base OID .1.3.6.1.4.1.664.6.10000.53.1.10. Monitored SNMP traps/notifications include adGenAOSOverTempProtectionShutdown, adGenAOSOverTempProtectionShutdownResume, adGenAOSOverTempProtectionWarning, adGenAOSOverTempProtectionWarningResume.

Key OID Definitions in ADTRAN-AOS-OVER-TEMP-PROTECTION-MIB

adGenAOSOverTempProtectionMibMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.664.6.10000.53.1.10

The MIB module defines over-temperature configuration information and traps for AdtranOS products.

adGenAOSOverTempProtectionShutdownNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.664.5.53.1.10.0.2

An over-temperature shutdown trap signifies that the shutdown temperature threshold has been exceeded, and the unit will restart into low-power mode.

adGenAOSOverTempProtectionShutdownResumeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.664.5.53.1.10.0.4

An over-temperature shutdown resume trap signifies that the shutdown temperature threshold has been resumed, and the unit has come back to normal mode from low-power mode.

adGenAOSOverTempProtectionWarningNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.664.5.53.1.10.0.1

An over-temperature warning trap signifies that the warning temperature threshold has been exceeded.

adGenAOSOverTempProtectionWarningResumeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.664.5.53.1.10.0.3

An over-temperature warning resume trap signifies that the warning temperature threshold has been resumed back to normal.

adGenAOSOverTempProtectionFullComplianceunknownnot-accessible
.1.3.6.1.4.1.664.5.53.99.19.2.1

The compliance statement for SNMP entities which implement version 2 of the adGenAosOverTempProtection MIB. When the implementation of this MIB supports adGenAOSOverTempProtectionNotificationGroup, then such an implementation can claim full compliance.

adGenAOSOverTempProtectionNotificationGroupunknownnot-accessible
.1.3.6.1.4.1.664.5.53.99.19.1.1

Traps which may be used to enhance event driven management of the chassis's over-temperature protection subsystem.

More MIBs from Adtran

Browse all AdtranMIBs →