ADTRAN-AOS-FAN-MIB
The ADTRAN-AOS-FAN-MIB enables SNMP-based monitoring and configuration of cooling fan states, speeds, and failure events on AdtranOS network infrastructure. It facilitates the retrieval of fan operational metrics and the reception of traps to alert administrators of hardware cooling anomalies or component failures.
Imported Objects
Objects
15 total| Object Name |
|---|
adGenAOSFan OBJECT IDENTIFIER .1.3.6.1.4.1.664.5.53.1.8 |
adGenAOSFanTrap OBJECT IDENTIFIER .1.3.6.1.4.1.664.5.53.1.8.0 |
adGenAOSFanFailure NOTIFICATION-TYPE .1.3.6.1.4.1.664.5.53.1.8.0.1 |
adGenAOSFanTrapControl OBJECT IDENTIFIER .1.3.6.1.4.1.664.5.53.1.8.1 |
adGenAOSFanTrapEnablerw Enumeration .1.3.6.1.4.1.664.5.53.1.8.1.1 |
adGenAOSFanInfo OBJECT IDENTIFIER .1.3.6.1.4.1.664.5.53.1.8.2 |
adGenAOSFanNumberro Integer32 .1.3.6.1.4.1.664.5.53.1.8.2.1 |
adGenAOSFanConformance OBJECT IDENTIFIER .1.3.6.1.4.1.664.5.53.99.17 |
adGenAOSFanGroups OBJECT IDENTIFIER .1.3.6.1.4.1.664.5.53.99.17.1 |
adGenAOSFanTrapCfgGroup Unknown .1.3.6.1.4.1.664.5.53.99.17.1.1 |
adGenAOSFanTrapGroup Unknown .1.3.6.1.4.1.664.5.53.99.17.1.2 |
adGenAOSFanNotificationGroup Unknown .1.3.6.1.4.1.664.5.53.99.17.1.3 |
adGenAOSFanCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.664.5.53.99.17.2 |
adGenAOSFanFullCompliance Unknown .1.3.6.1.4.1.664.5.53.99.17.2.1 |
adGenAOSFanMib MODULE-IDENTITY .1.3.6.1.4.1.664.6.10000.53.1.8 |
ADTRAN-AOS-FAN-MIB Technical Reference Overview
The ADTRAN-AOS-FAN-MIB SNMP MIB module published by Adtran defines 15 managed OID objects, including 6 scalar/column metrics, 0 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.664.6.10000.53.1.8. Monitored SNMP traps/notifications include adGenAOSFanFailure.
Key OID Definitions in ADTRAN-AOS-FAN-MIB
.1.3.6.1.4.1.664.6.10000.53.1.8The MIB module defines fan configuration information and traps for AdtranOS products.
.1.3.6.1.4.1.664.5.53.1.8.0.1A fan failure trap signifies that one of the fans inside the chassis has failed.
.1.3.6.1.4.1.664.5.53.99.17.2.1The compliance statement for SNMP entities which implement version 2 of the adGenAosFan MIB. When this MIB is implemented with support for read-write, then such an implementation can claim full compliance.
.1.3.6.1.4.1.664.5.53.99.17.1.3Traps which may be used to enhance event driven management of the chassis's fan.
.1.3.6.1.4.1.664.5.53.1.8.2.1A numerical representation of the chassis's fan.
.1.3.6.1.4.1.664.5.53.99.17.1.1This group contains the objects necessary to enable/disable fan failure traps.
.1.3.6.1.4.1.664.5.53.1.8.1.1This variable indicates whether the system produces the fan failure trap.
.1.3.6.1.4.1.664.5.53.99.17.1.2The objects necessary to control fan notification messages.
More MIBs from Adtran
Browse all AdtranMIBs →The ADTRAN-AOS-VQM MIB module enables monitoring of Voice Quality Management metrics, including MOS scores, packet loss, jitter, and latency, on ADTRAN AOS-based network devices. It facilitates the collection of real-time voice performance data to assess and troubleshoot VoIP call quality across the network infrastructure.
The ADTRAN-AOS-NETWORKMONITOR MIB module enables SNMP-based monitoring of network performance metrics and operational states on ADTRAN AOS (Advanced Operating System) network devices. It provides access to counters and gauges for interface traffic, link status, and system resource utilization to facilitate real-time network health assessment and capacity planning.
Standard SNMP MIB module defining data structures for ADTRAN-ACTDAXL3-MIB.
Standard SNMP MIB module defining data structures for ADTRAN-TSUIQ-MIB.
Standard SNMP MIB module defining data structures for ADTRAN-FRPerform-MIB.