ZYXEL-accessSwitch-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for ZYXEL-accessSwitch-MIB.
85
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
85 total| Object Name |
|---|
zyxel OBJECT IDENTIFIER .1.3.6.1.4.1.890 |
RFC1155-SMI Unknown .1.3.6.1.4.1.890 |
products OBJECT IDENTIFIER .1.3.6.1.4.1.890.1 |
accessSwitch OBJECT IDENTIFIER .1.3.6.1.4.1.890.1.5 |
rebootSend a message to the manager that the system is going to reboot.
The variable is the reason why the system reboots. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.1 |
systemShutdownSend a message to the manager that the system is going to shutdown.
The variable is the reason that causes the system to shutdown. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.2 |
overheatSend a message to the manager that the system is overheated.
The variable in the binding list is the current temperature in Celsius
of the system. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.3 |
overheatOverSend a message to the manager that the overheated condition is over.
The variable in the binding list is the current temperature in Celsius
of the system. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.4 |
errLogSend a message to the manager that an error log is created in system.
The variable in the binding list is the content of the error log. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.5 |
fanRpmLowSend a message to the manager that the rpm of the fan is too low.
The variable in the binding list is the current rpm of the fan. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.6 |
fanRpmNormalSend a message to the manager that the low-rpm condition of the fan is over.
The variable in the binding list is the current rpm of the fan. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.7 |
voltageOutOfRangeSend a message to the manager that the voltage of the system is out of range.
The variable in the binding list is the current voltage in volt
of the system. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.8 |
voltageNormalSend a message to the manager that the low-voltage condition is over.
The variable in the binding list is the current voltage in volt
of the system. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.9 |
systemMaintenanceFailureSend a message to the manager that the system maintence operation
fail. The variable in the variable binding indicates the problem. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.10 |
configChangeSend a message to the manager that the system configuration
data is changed. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.11 |
thermalSensorFailureThe trap signifies that the thermal sensor failed. TRAP-TYPE .1.3.6.1.4.1.890.1.5.0.12 |
accessSwitchCommon OBJECT IDENTIFIER .1.3.6.1.4.1.890.1.5.1 |
accessSwitchMgnt OBJECT IDENTIFIER .1.3.6.1.4.1.890.1.5.1.1 |
accessSwitchSystemCurrentStatusThis variable indicates the status of the system.
The sysCurrentStatus is a bit map represented
as a sum, therefore, it can represent multiple defects
simultaneously. The sysNoDefect should be set if and only if
no other flag is set.
The various bit positions are:
1 sysNoDefect
2 sysOverHeat
3 sysFanRpmLow
4 sysVoltageLow
5 sysThermalSensorFailurero INTEGER .1.3.6.1.4.1.890.1.5.1.1.1 |
accessSwitchProblemCauseThe variable is the description of sytsem problem.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.2 |
accessSwitchSystemTemperatureThe variable is the current temperature in Celsius of the system.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.3 |
accessSwitchFanRpmTableA table that contains rpm information about the fans. SEQUENCE OF AccessSwitchFanRpmEntry .1.3.6.1.4.1.890.1.5.1.1.4 |
accessSwitchFanRpmEntryA list of rpm information for each fan. AccessSwitchFanRpmEntry .1.3.6.1.4.1.890.1.5.1.1.4.1 |
accessSwitchFanRpmIndexThe identity of the fan.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.4.1.1 |
accessSwitchFanRpmCurValueThe current rpm of the fan.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.4.1.2 |
accessSwitchFanRpmMaxValueThe maximum rpm ever performed by the fan.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.4.1.3 |
accessSwitchFanRpmMinValueThe minimum rpm ever performed by the fan.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.4.1.4 |
accessSwitchFanRpmLowThreshThe low threshold of the rpm of the fan. If the current rpm is less than
the threshold, the device will initiate the fanRpmLow trap.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.4.1.5 |
accessSwitchFanRpmDescrThe description of the fan (e.g. location, function, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.4.1.6 |
accessSwitchVoltageTableA table that contains voltage information about the system. SEQUENCE OF AccessSwitchVoltageEntry .1.3.6.1.4.1.890.1.5.1.1.5 |
accessSwitchVoltageEntryA list of voltage information for each sensor. AccessSwitchVoltageEntry .1.3.6.1.4.1.890.1.5.1.1.5.1 |
accessSwitchVoltageIndexThe identity of the sensor.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.5.1.1 |
accessSwitchVoltageCurValueThe current voltage detected by the sensor (in milli-voltage).ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.5.1.2 |
accessSwitchVoltageMaxValueThe maximum voltage ever detected by the sensor (in milli-voltage).ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.5.1.3 |
accessSwitchVoltageMinValueThe minimum voltage ever detected by the sensor (in milli-voltage).ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.5.1.4 |
accessSwitchVoltageNominalValueThe nominal voltage which the power should supply (in milli-voltage).ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.5.1.5 |
accessSwitchVoltageLowThreshThe low threshold of the voltage. If the current voltage is less than
the threshold, the device will initiate the voltageLow trap.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.5.1.6 |
accessSwitchVoltageDescrThe description of the voltage (e.g. location, nominal value, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.5.1.7 |
accessSwitchSysTempTableA table that contains temperature information about system. SEQUENCE OF AccessSwitchSysTempEntry .1.3.6.1.4.1.890.1.5.1.1.6 |
accessSwitchSysTempEntryA list of temperature information for each sensor. AccessSwitchSysTempEntry .1.3.6.1.4.1.890.1.5.1.1.6.1 |
accessSwitchSysTempIndexThe identity of the sensor.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.6.1.1 |
accessSwitchSysTempCurValueThe current temperature detected in Celsius by the sensor.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.6.1.2 |
accessSwitchSysTempMaxValueThe maximum temperature ever detected in Celsius by the sensor.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.6.1.3 |
accessSwitchSysTempMinValueThe minimum temperature ever detected in Celsius by the sensor.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.6.1.4 |
accessSwitchSysTempHighThreshThe high threshold of the temperature in Celsius. If the current temperature
is higher than the threshold, the device will initiate the overheat trap.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.6.1.5 |
accessSwitchSysTempDescrThe description of the temperature sensor (e.g. location, function, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.6.1.6 |
accessSwitchMaintenanceThe managed object is for system maintenance. When the EMS
wants to trigger the system maitenance operation, the EMS
shall send SNMP-SET message to set the corresponding bit value
to be 1. The various bit positions are:
BIT 1: config save
BIT 2: reset
BIT 3: local loopback test
BIT 4: remote loopback testrw INTEGER .1.3.6.1.4.1.890.1.5.1.1.7 |
accessSwitchMaintenancePortThe port which the maintenance operation should be performed on.
The value of 0 means the maintenance should be performed on the system.rw INTEGER .1.3.6.1.4.1.890.1.5.1.1.8 |
accessSwitchMaxNumOfStaticVlansThe maximum number of static VLANs which the system supportsro INTEGER .1.3.6.1.4.1.890.1.5.1.1.9 |
acccessSwitchChassisIdThe chassis Id of the modulerw INTEGER .1.3.6.1.4.1.890.1.5.1.1.10 |
accessSwitchSlotIdThe slot Id of the modulerw ASSlotNum .1.3.6.1.4.1.890.1.5.1.1.11 |
accessSwitchModuleTypeThe type of the modulero ASModuleType .1.3.6.1.4.1.890.1.5.1.1.12 |
accessSwitchFWVersionThe firmware version of the access switch.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.13 |
accessSwitchDriverVersionThe driver version of the access port in this access switchro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.14 |
accessSwitchModemCodeVersionThe modem code version of the access port in this access switchro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.15 |
accessSwitchDSLConfOpsThe managed object is for xDSL line configuration. When the EMS
wants to issue the desired operation, the EMS
shall send SNMP-SET message to set the corresponding bit value
to be 1. The various bit positions are:
BIT 1: enable port
BIT 2: disable port
BIT 3: set DSL mode
BIT 4: set profilerw INTEGER .1.3.6.1.4.1.890.1.5.1.1.16 |
accessSwitchDSLConfTargetThe managed object is used for identify the target on which
the line configuration should be performed. The target is encoded
as:
Byte 1~4: reserved
Byte 5~7: each octet specifies a set of eight ports, with the first
octet specifying ports 1 through 8, etc.
Byte 8~10: reservedrw OCTET STRING .1.3.6.1.4.1.890.1.5.1.1.17 |
accessSwitchDSLConfProfileNameThe DSL profile namerw DisplayString .1.3.6.1.4.1.890.1.5.1.1.18 |
accessSwitchDSLConfModeThe DSL mode. The semantic for each bit is:
Bit 1: ADSL, G.lite
Bit 2: ADSL, G.dmt
Bit 3: ADSL, T1.413
Bit 4: ADSL, Autorw INTEGER .1.3.6.1.4.1.890.1.5.1.1.19 |
asPacketForwardingTableThis table includes the configuration of packet forwarding. SEQUENCE OF AsPacketForwardingEntry .1.3.6.1.4.1.890.1.5.1.1.20 |
asPacketForwardingEntryAn entry in asPacketForwardingTable. AsPacketForwardingEntry .1.3.6.1.4.1.890.1.5.1.1.20.1 |
asPacketForwardingPortListThe list defines the ports to which the packets
will be forwarded.rw PortList (Q-BRIDGE-MIB) .1.3.6.1.4.1.890.1.5.1.1.20.1.1 |
asDhcpRelayEnableEnable/disable DHCP relay function.rw Enumeration .1.3.6.1.4.1.890.1.5.1.1.21 |
asDhcpRelayOption82EnableEnable/disable the relay agent information option.rw Enumeration .1.3.6.1.4.1.890.1.5.1.1.22 |
asDhcpRelayOption82InfoUser specific relay agent information.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.23 |
asMaxNumOfDhcpServersThe maximum number of DHCP servers.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.24 |
asDhcpServerTableA table that contains DHCP server information. SEQUENCE OF AsDhcpServerEntry .1.3.6.1.4.1.890.1.5.1.1.25 |
asDhcpServerEntryThe entry of DHCP server table. AsDhcpServerEntry .1.3.6.1.4.1.890.1.5.1.1.25.1 |
asDhcpServerIpThe IP address of the DHCP server.rw IpAddress .1.3.6.1.4.1.890.1.5.1.1.25.1.1 |
asDhcpServerRowStatusThe row status of the DHCP server entry.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.25.1.2 |
asMaxNumberOfRadiusServersThe max number of the RADIUS Servers.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.28 |
asRadiusServerTableA table that contains Radius Server information. SEQUENCE OF AsRadiusServerEntry .1.3.6.1.4.1.890.1.5.1.1.29 |
asRadiusServerEntryThe entry of Radius Server table. AsRadiusServerEntry .1.3.6.1.4.1.890.1.5.1.1.29.1 |
asRadiusServerIndexThe identity of the RADIUS server.ro INTEGER .1.3.6.1.4.1.890.1.5.1.1.29.1.1 |
asRadiusServerIpThe IP address of the Radius Server.rw IpAddress .1.3.6.1.4.1.890.1.5.1.1.29.1.2 |
asRadiusServerPortThe UDP port of the Radius Server.rw INTEGER .1.3.6.1.4.1.890.1.5.1.1.29.1.3 |
asRadiusSharedSecretThe shared secret of the Radius Server.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.29.1.4 |
asRadiusServerRowStatusThe row status of the Radius Server entry.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.890.1.5.1.1.29.1.5 |
asDot1xEnableEnable/disable the 802.1x function.rw Enumeration .1.3.6.1.4.1.890.1.5.1.1.30 |
asDot1xPortTableThis table includes the configuration of 802.1x. SEQUENCE OF AsDot1xPortEntry .1.3.6.1.4.1.890.1.5.1.1.31 |
asDot1xPortEntryAn entry in asDot1xPortTable. AsDot1xPortEntry .1.3.6.1.4.1.890.1.5.1.1.31.1 |
asDot1xPortEnableThe option defines if the port enables 802.1x
settings.rw Enumeration .1.3.6.1.4.1.890.1.5.1.1.31.1.1 |
asDot1xPortControlThe configuration defines the 802.1x port control
type.rw Enumeration .1.3.6.1.4.1.890.1.5.1.1.31.1.2 |
asDot1xPortReAuthEnableThe option defines if the port enables 802.1x
re-authentication.rw Enumeration .1.3.6.1.4.1.890.1.5.1.1.31.1.3 |
asDot1xPortReAuthPeriodThe configuration defines the 802.1x
re-authentication period for each port.rw INTEGER .1.3.6.1.4.1.890.1.5.1.1.31.1.4 |