ZYXEL-accessSwitch-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ZYXEL-accessSwitch-MIB.

85
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

85 total
Object Name
zyxel
OBJECT IDENTIFIER
.1.3.6.1.4.1.890
RFC1155-SMI
Unknown
.1.3.6.1.4.1.890
products
OBJECT IDENTIFIER
.1.3.6.1.4.1.890.1
accessSwitch
OBJECT IDENTIFIER
.1.3.6.1.4.1.890.1.5
rebootSend a message to the manager that the system is going to reboot. The variable is the reason why the system reboots.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.1
systemShutdownSend a message to the manager that the system is going to shutdown. The variable is the reason that causes the system to shutdown.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.2
overheatSend a message to the manager that the system is overheated. The variable in the binding list is the current temperature in Celsius of the system.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.3
overheatOverSend a message to the manager that the overheated condition is over. The variable in the binding list is the current temperature in Celsius of the system.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.4
errLogSend a message to the manager that an error log is created in system. The variable in the binding list is the content of the error log.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.5
fanRpmLowSend a message to the manager that the rpm of the fan is too low. The variable in the binding list is the current rpm of the fan.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.6
fanRpmNormalSend a message to the manager that the low-rpm condition of the fan is over. The variable in the binding list is the current rpm of the fan.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.7
voltageOutOfRangeSend a message to the manager that the voltage of the system is out of range. The variable in the binding list is the current voltage in volt of the system.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.8
voltageNormalSend a message to the manager that the low-voltage condition is over. The variable in the binding list is the current voltage in volt of the system.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.9
systemMaintenanceFailureSend a message to the manager that the system maintence operation fail. The variable in the variable binding indicates the problem.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.10
configChangeSend a message to the manager that the system configuration data is changed.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.11
thermalSensorFailureThe trap signifies that the thermal sensor failed.
TRAP-TYPE
.1.3.6.1.4.1.890.1.5.0.12
accessSwitchCommon
OBJECT IDENTIFIER
.1.3.6.1.4.1.890.1.5.1
accessSwitchMgnt
OBJECT IDENTIFIER
.1.3.6.1.4.1.890.1.5.1.1
accessSwitchSystemCurrentStatusThis variable indicates the status of the system. The sysCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sysNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sysNoDefect 2 sysOverHeat 3 sysFanRpmLow 4 sysVoltageLow 5 sysThermalSensorFailurero
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.1
accessSwitchProblemCauseThe variable is the description of sytsem problem.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.2
accessSwitchSystemTemperatureThe variable is the current temperature in Celsius of the system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.3
accessSwitchFanRpmTableA table that contains rpm information about the fans.
SEQUENCE OF AccessSwitchFanRpmEntry
.1.3.6.1.4.1.890.1.5.1.1.4
accessSwitchFanRpmEntryA list of rpm information for each fan.
AccessSwitchFanRpmEntry
.1.3.6.1.4.1.890.1.5.1.1.4.1
accessSwitchFanRpmIndexThe identity of the fan.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.4.1.1
accessSwitchFanRpmCurValueThe current rpm of the fan.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.4.1.2
accessSwitchFanRpmMaxValueThe maximum rpm ever performed by the fan.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.4.1.3
accessSwitchFanRpmMinValueThe minimum rpm ever performed by the fan.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.4.1.4
accessSwitchFanRpmLowThreshThe low threshold of the rpm of the fan. If the current rpm is less than the threshold, the device will initiate the fanRpmLow trap.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.4.1.5
accessSwitchFanRpmDescrThe description of the fan (e.g. location, function, etc.).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.4.1.6
accessSwitchVoltageTableA table that contains voltage information about the system.
SEQUENCE OF AccessSwitchVoltageEntry
.1.3.6.1.4.1.890.1.5.1.1.5
accessSwitchVoltageEntryA list of voltage information for each sensor.
AccessSwitchVoltageEntry
.1.3.6.1.4.1.890.1.5.1.1.5.1
accessSwitchVoltageIndexThe identity of the sensor.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.5.1.1
accessSwitchVoltageCurValueThe current voltage detected by the sensor (in milli-voltage).ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.5.1.2
accessSwitchVoltageMaxValueThe maximum voltage ever detected by the sensor (in milli-voltage).ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.5.1.3
accessSwitchVoltageMinValueThe minimum voltage ever detected by the sensor (in milli-voltage).ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.5.1.4
accessSwitchVoltageNominalValueThe nominal voltage which the power should supply (in milli-voltage).ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.5.1.5
accessSwitchVoltageLowThreshThe low threshold of the voltage. If the current voltage is less than the threshold, the device will initiate the voltageLow trap.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.5.1.6
accessSwitchVoltageDescrThe description of the voltage (e.g. location, nominal value, etc.).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.5.1.7
accessSwitchSysTempTableA table that contains temperature information about system.
SEQUENCE OF AccessSwitchSysTempEntry
.1.3.6.1.4.1.890.1.5.1.1.6
accessSwitchSysTempEntryA list of temperature information for each sensor.
AccessSwitchSysTempEntry
.1.3.6.1.4.1.890.1.5.1.1.6.1
accessSwitchSysTempIndexThe identity of the sensor.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.6.1.1
accessSwitchSysTempCurValueThe current temperature detected in Celsius by the sensor.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.6.1.2
accessSwitchSysTempMaxValueThe maximum temperature ever detected in Celsius by the sensor.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.6.1.3
accessSwitchSysTempMinValueThe minimum temperature ever detected in Celsius by the sensor.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.6.1.4
accessSwitchSysTempHighThreshThe high threshold of the temperature in Celsius. If the current temperature is higher than the threshold, the device will initiate the overheat trap.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.6.1.5
accessSwitchSysTempDescrThe description of the temperature sensor (e.g. location, function, etc.).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.6.1.6
accessSwitchMaintenanceThe managed object is for system maintenance. When the EMS wants to trigger the system maitenance operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: config save BIT 2: reset BIT 3: local loopback test BIT 4: remote loopback testrw
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.7
accessSwitchMaintenancePortThe port which the maintenance operation should be performed on. The value of 0 means the maintenance should be performed on the system.rw
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.8
accessSwitchMaxNumOfStaticVlansThe maximum number of static VLANs which the system supportsro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.9
acccessSwitchChassisIdThe chassis Id of the modulerw
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.10
accessSwitchSlotIdThe slot Id of the modulerw
ASSlotNum
.1.3.6.1.4.1.890.1.5.1.1.11
accessSwitchModuleTypeThe type of the modulero
ASModuleType
.1.3.6.1.4.1.890.1.5.1.1.12
accessSwitchFWVersionThe firmware version of the access switch.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.13
accessSwitchDriverVersionThe driver version of the access port in this access switchro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.14
accessSwitchModemCodeVersionThe modem code version of the access port in this access switchro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.15
accessSwitchDSLConfOpsThe managed object is for xDSL line configuration. When the EMS wants to issue the desired operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: enable port BIT 2: disable port BIT 3: set DSL mode BIT 4: set profilerw
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.16
accessSwitchDSLConfTargetThe managed object is used for identify the target on which the line configuration should be performed. The target is encoded as: Byte 1~4: reserved Byte 5~7: each octet specifies a set of eight ports, with the first octet specifying ports 1 through 8, etc. Byte 8~10: reservedrw
OCTET STRING
.1.3.6.1.4.1.890.1.5.1.1.17
accessSwitchDSLConfProfileNameThe DSL profile namerw
DisplayString
.1.3.6.1.4.1.890.1.5.1.1.18
accessSwitchDSLConfModeThe DSL mode. The semantic for each bit is: Bit 1: ADSL, G.lite Bit 2: ADSL, G.dmt Bit 3: ADSL, T1.413 Bit 4: ADSL, Autorw
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.19
asPacketForwardingTableThis table includes the configuration of packet forwarding.
SEQUENCE OF AsPacketForwardingEntry
.1.3.6.1.4.1.890.1.5.1.1.20
asPacketForwardingEntryAn entry in asPacketForwardingTable.
AsPacketForwardingEntry
.1.3.6.1.4.1.890.1.5.1.1.20.1
asPacketForwardingPortListThe list defines the ports to which the packets will be forwarded.rw
PortList (Q-BRIDGE-MIB)
.1.3.6.1.4.1.890.1.5.1.1.20.1.1
asDhcpRelayEnableEnable/disable DHCP relay function.rw
Enumeration
.1.3.6.1.4.1.890.1.5.1.1.21
asDhcpRelayOption82EnableEnable/disable the relay agent information option.rw
Enumeration
.1.3.6.1.4.1.890.1.5.1.1.22
asDhcpRelayOption82InfoUser specific relay agent information.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.23
asMaxNumOfDhcpServersThe maximum number of DHCP servers.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.24
asDhcpServerTableA table that contains DHCP server information.
SEQUENCE OF AsDhcpServerEntry
.1.3.6.1.4.1.890.1.5.1.1.25
asDhcpServerEntryThe entry of DHCP server table.
AsDhcpServerEntry
.1.3.6.1.4.1.890.1.5.1.1.25.1
asDhcpServerIpThe IP address of the DHCP server.rw
IpAddress
.1.3.6.1.4.1.890.1.5.1.1.25.1.1
asDhcpServerRowStatusThe row status of the DHCP server entry.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.25.1.2
asMaxNumberOfRadiusServersThe max number of the RADIUS Servers.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.28
asRadiusServerTableA table that contains Radius Server information.
SEQUENCE OF AsRadiusServerEntry
.1.3.6.1.4.1.890.1.5.1.1.29
asRadiusServerEntryThe entry of Radius Server table.
AsRadiusServerEntry
.1.3.6.1.4.1.890.1.5.1.1.29.1
asRadiusServerIndexThe identity of the RADIUS server.ro
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.29.1.1
asRadiusServerIpThe IP address of the Radius Server.rw
IpAddress
.1.3.6.1.4.1.890.1.5.1.1.29.1.2
asRadiusServerPortThe UDP port of the Radius Server.rw
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.29.1.3
asRadiusSharedSecretThe shared secret of the Radius Server.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.29.1.4
asRadiusServerRowStatusThe row status of the Radius Server entry.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.890.1.5.1.1.29.1.5
asDot1xEnableEnable/disable the 802.1x function.rw
Enumeration
.1.3.6.1.4.1.890.1.5.1.1.30
asDot1xPortTableThis table includes the configuration of 802.1x.
SEQUENCE OF AsDot1xPortEntry
.1.3.6.1.4.1.890.1.5.1.1.31
asDot1xPortEntryAn entry in asDot1xPortTable.
AsDot1xPortEntry
.1.3.6.1.4.1.890.1.5.1.1.31.1
asDot1xPortEnableThe option defines if the port enables 802.1x settings.rw
Enumeration
.1.3.6.1.4.1.890.1.5.1.1.31.1.1
asDot1xPortControlThe configuration defines the 802.1x port control type.rw
Enumeration
.1.3.6.1.4.1.890.1.5.1.1.31.1.2
asDot1xPortReAuthEnableThe option defines if the port enables 802.1x re-authentication.rw
Enumeration
.1.3.6.1.4.1.890.1.5.1.1.31.1.3
asDot1xPortReAuthPeriodThe configuration defines the 802.1x re-authentication period for each port.rw
INTEGER
.1.3.6.1.4.1.890.1.5.1.1.31.1.4