Home/Catalog/SUN-SNMP-NETRA-CT-RSC-MIB

SUN-SNMP-NETRA-CT-RSC-MIB

AI MIB Summary

The SUN-SNMP-NETRA-CT-RSC-MIB enables remote out-of-band management and monitoring of Sun Netra CT 400 and 800 server chassis via the Sun Remote System Control (RSC) firmware. It provides SNMP-accessible metrics for hardware power states, system health sensors, and console redirection sessions to facilitate server recovery and configuration without physical access.

The MIB module for the Netra ct 400/800 Remote System Control Products
Main OID:
netraCtRscMIB.1.3.6.1.4.1.42.2.65.2
130
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

130 total
Object Name
netraCtRscMIBThe MIB module for the Netra ct 400/800 Remote System Control Products
MODULE-IDENTITY
.1.3.6.1.4.1.42.2.65.2
netraCtRscObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.1
netraCtRscAdminObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.1.1
netraCtRscAdminRscResetSetting this will soft Reset only the RSC (Remote System Controller) card. The clear(2) setting is read-only for this variable. This variable will always read as clear(2).rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.1.1
netraCtRscAdminHostResetSetting netraCtRscAdminHostReset will cause either send a break to the host, or will toggle a hard reset line. A break will be sent if netraCtRscPanicDump conatins the value of on(1).Otherwise, a hard reset will occur. The clear(2) setting is read-only for this variable. This variable will always reads as clear(2).rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.1.2
netraCtRscAdminXirSends a hardware xir pulse to the host when set to true. This variable resets itself to clear(2) after the negation of the pulse.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.1.3
netraCtRscAdminNmiSends a hardware nmi pulse to the host when set to true. This variable resets itself to clear(2) after the negation of the pulse.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.1.4
netraCtRscAdminBreakSends a break to the Host when this is set. The clear(2) setting is read-only for this variable. This variable will always read as clear(2).rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.1.5
netraCtRscConfigObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.1.2
netraCtRscGlobalPageFlagAn on(1) to this variable will enable paging for RSC alerts. An off(2) will disable paging.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.2.1
netraCtRscGlobalEmailFlagAn on(1) to this variable will enable email for RSC alerts. An off(2) will disable email.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.2.2
netraCtRscGlobalIPModeFlagIP mode global flagrw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.2.3
netraCtRscGlobalPPPFlagserial configuration flag indicating whether PPP should be the default.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.2.4
netraCtRscHostnamename of Host connected to RSCrw
DisplayString
.1.3.6.1.4.1.42.2.65.2.1.2.5
netraCtRscCustomerInfoCustomer information used in the message generated for a pager or email alertrw
DisplayString
.1.3.6.1.4.1.42.2.65.2.1.2.6
netraCtRscVersionBootMajorRSC Firmware BootMonitor Revision Major Numberro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.2.7
netraCtRscVersionBootMinorRSC Firmware BootMonitor Revision Minor Numberro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.2.8
netraCtRscVersionBootMicroRSC Firmware BootMonitor Revision Micro Numberro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.2.9
netraCtRscVersionMainMajorRSC Core RSC Revision Major Numberro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.2.10
netraCtRscVersionMainMinorRSC Core RSC Revision Minor Numberro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.2.11
netraCtRscVersionMainMicroRSC Core RSC Revision Micro Numberro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.2.12
netraCtRscVersionFirmwareMajorRSC Core Firmware Revision Major Numberro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.2.13
netraCtRscVersionFirmwareMinorRSC Core Firmware Revision Minor Numberro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.2.14
netraCtRscVersionFirmwareMicroRSC Core Firmware Revision Micro Numberro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.2.15
netraCtRscTODRSC time of dayrw
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.42.2.65.2.1.2.16
netraCtRscEscapeset the first character of the 2-character escape sequencerw
DisplayString
.1.3.6.1.4.1.42.2.65.2.1.2.17
netraCtRscHostWatchDogRebootRSC monitors a heartbeat from the Solaris host. If this heartbeat is late, then a message will be logged, and an alarm will be set. If netraCtRscHostWatchDogReboot is on, then the solaris host will also be rebooted.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.2.18
netraCtRscHostWatchDogTimeoutRSC monitors a heartbeat from the Solaris host. This variable indicates the maximum tolerable number of seconds between heartbeats, before RSC will set alarm0. A setting of 0 indicates that the heartbeat should not be monitored.rw
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.2.19
netraCtRscPanicDumpIf set to true when netraCtRscAdminHostReset is set, then a break will be sent to the host, causing a core dump to be saved on the host. Otherwise, the setting of netraCtRscAdminHostReset will cause a hardware reset.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.2.20
netraCtRscSerial2Objs
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.1.3
netraCtRscSerial2Modeserial port 2 configuration mode.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.1
netraCtRscSerial2Parityserial port 2 parity mode.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.2
netraCtRscSerial2Stopserial port 2 stop bits.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.3
netraCtRscSerial2Dataserial port 2 data bits.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.4
netraCtRscSerial2Baudserial port 2 baud rate.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.5
netraCtRscSerial2HwFlowcontrolserial port 2 Hardware Flowcontrol.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.6
netraCtRscSerial2Inactivityserial port 2 inactivity.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.7
netraCtRscSerial2PagerOneConfigprimary pager number for RSC.rw
DisplayString
.1.3.6.1.4.1.42.2.65.2.1.3.8
netraCtRscSerial2PagerTwoConfigsecondary pager number for RSCrw
DisplayString
.1.3.6.1.4.1.42.2.65.2.1.3.9
netraCtRscSerial2PagerOneBaudprimary pager baud rate.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.10
netraCtRscSerial2PagerTwoBaudsecondary pager baud rate.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.11
netraCtRscSerial2PagerOneParityprimary pager parity mode.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.12
netraCtRscSerial2PagerTwoParitysecondary pager parity mode.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.13
netraCtRscSerial2PagerOneStopprimary pager stop bits.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.14
netraCtRscSerial2PagerTwoStopsecondary pager stop bits.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.15
netraCtRscSerial2PagerOneDataprimary pager data bits.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.16
netraCtRscSerial2PagerTwoDatasecondary pager data bits.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.3.17
netraCtRscSerial2PagerOneInitprimary pager modem init string.rw
DisplayString
.1.3.6.1.4.1.42.2.65.2.1.3.18
netraCtRscSerial2PagerTwoInitsecondary pager modem init string.rw
DisplayString
.1.3.6.1.4.1.42.2.65.2.1.3.19
netraCtRscSerial2PagerOnePasswordprimary pager TAP password.rw
DisplayString
.1.3.6.1.4.1.42.2.65.2.1.3.20
netraCtRscSerial2PagerTwoPasswordsecondary pager TAP password.rw
DisplayString
.1.3.6.1.4.1.42.2.65.2.1.3.21
netraCtRscModemObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.1.4
netraCtRscModemParitymodem parity mode.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.4.1
netraCtRscModemStopmodem stop bits.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.4.2
netraCtRscModemDatamodem data bits.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.4.3
netraCtRscCountryCodecountry specified using CCITT internaional dial-plan number.rw
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.4.4
netraCtRscModemModelthe modem type used on the netraCtRsc card.ro
DisplayString
.1.3.6.1.4.1.42.2.65.2.1.4.5
netraCtRscEnetObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.1.5
netraCtRscMacAddressEthernet address for RSC.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.42.2.65.2.1.5.1
netraCtRscEnetTpeLinkTestDetermines whether tpe-link-test should be set of clear. This should be off when interfacing with older-style hubs that don't support heartbeat.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.5.2
netraCtRscIPAddressconfigured IP address for RSC.rw
IpAddress
.1.3.6.1.4.1.42.2.65.2.1.5.3
netraCtRscIpMaskconfigured IP netmask for RSC.rw
IpAddress
.1.3.6.1.4.1.42.2.65.2.1.5.4
netraCtRscIpGatewayconfigured IP gateway for RSC.rw
IpAddress
.1.3.6.1.4.1.42.2.65.2.1.5.5
netraCtRscSNMPHostAddressconfigured SNMP server for RSC alerts.rw
IpAddress
.1.3.6.1.4.1.42.2.65.2.1.5.6
netraCtRscMailHostAddressAddress of Mail Server.rw
IpAddress
.1.3.6.1.4.1.42.2.65.2.1.5.7
netraCtRscMailUseremail address for RSC alerts.rw
DisplayString
.1.3.6.1.4.1.42.2.65.2.1.5.8
netraCtRscPPPLocalIPPPP local IP address.rw
IpAddress
.1.3.6.1.4.1.42.2.65.2.1.5.9
netraCtRscPPPRemoteIPPPP remote IP address.rw
IpAddress
.1.3.6.1.4.1.42.2.65.2.1.5.10
netraCtRscMailHostAddressBackupBackup Address of Mail Server. when no IP address is configured for mail server, back up IP address becomes first IP address of mailhostrw
IpAddress
.1.3.6.1.4.1.42.2.65.2.1.5.11
netraCtRscEnvObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.1.6
netraCtRscSystemTypeSystem Type. This will currently return one of the following 2 strings: NetraCt400 , or NetraCt800.ro
DisplayString ( SIZE
.1.3.6.1.4.1.42.2.65.2.1.6.1
netraCtRscPowerSupplyCountThe total number of Power Supply FRUs in the platform.ro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.2
netraCtRscPowerSupplyTableA table listing the characteristics of the Power-Supply FRU.
SEQUENCE OF NetraCtRscPowerSupplyEntry
.1.3.6.1.4.1.42.2.65.2.1.6.3
netraCtRscPowerSupplyEntryan entry (conceptual row) in the netraCtRscPowerSupplyTable
NetraCtRscPowerSupplyEntry
.1.3.6.1.4.1.42.2.65.2.1.6.3.1
netraCtRscPowerSupplyIndexEntry number for this Power-Supply FRU row.ro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.3.1.1
netraCtRscPowerSupplyPresentPower-Supply FRU is present.ro
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.6.3.1.2
netraCtRscPowerSupplyOperStateThe current status of the Power-Supply FRU.ro
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.6.3.1.3
netraCtRscPowerSupplyAdminStateSetting this value to on(1) requests that the power supply be turned on. Setting this value to off(2) requests that the power supply be turned off.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.6.3.1.4
netraCtRscAlarmCountNumber of Alarm Ports in this Platformro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.4
netraCtRscAlarmTablea table listing the available Alarm Ports.
SEQUENCE OF NetraCtRscAlarmEntry
.1.3.6.1.4.1.42.2.65.2.1.6.5
netraCtRscAlarmEntryan entry (conceptual row) in the netraCtRscAlarmTable.
NetraCtRscAlarmEntry
.1.3.6.1.4.1.42.2.65.2.1.6.5.1
netraCtRscAlarmIndexrow index into Alarm Port table
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.5.1.1
netraCtRscAlarmIDAlarm identifier. The current Netra ct 400/800 Alarm Cards currently supports Alarm IDs of 0,1,2, and 3.ro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.5.1.2
netraCtRscAlarmOperStateThis returns the current value of the Alarm, which may have been set by either software due to environmental conditions, such as Fan failure, or manually, by the setting of netraCtRscAlarmAdminState.ro
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.6.5.1.3
netraCtRscAlarmAdminStateThis reflects the requested state of an alarm port by the SNMP manager.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.6.5.1.4
netraCtRscAlarmPrefixThe Alarm Prefix that will associate an FRU type to an alarm. Currently supported definitions are: cpuunit(1), software(2), powersupply(3), temperature(4), fan(5). 6 through 9 are reserved for future expansion. 10 through 255 are undefined, and can be configured for user-defined messages and alarming.ro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.5.1.5
netraCtRscFanCountMaximum number of Fan Tray FRUs in Platformro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.6
netraCtRscFanTablea table listing the characteristics of the Fan Tray FRU.
SEQUENCE OF NetraCtRscFanEntry
.1.3.6.1.4.1.42.2.65.2.1.6.7
netraCtRscFanEntryan entry (conceptual row) in the netraCtRscFanTable.
NetraCtRscFanEntry
.1.3.6.1.4.1.42.2.65.2.1.6.7.1
netraCtRscFanIndexrow index into Fan FRU tablero
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.7.1.1
netraCtRscFanPresentFan FRU is presentro
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.6.7.1.2
netraCtRscFanStatusThe current status of the Fan FRU. unknown will be returned if the status is unknown.ro
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.6.7.1.3
netraCtRscTemperatureCountMaximum number of temperature sensors on Platformro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.8
netraCtRscTemperatureTablea table listing the contents of the event log as an array of strings.
SEQUENCE OF NetraCtRscTemperatureEntry
.1.3.6.1.4.1.42.2.65.2.1.6.9
netraCtRscTemperatureEntryan entry (conceptual row) in the netraCtRscTemperatureTable.
NetraCtRscTemperatureEntry
.1.3.6.1.4.1.42.2.65.2.1.6.9.1
netraCtRscTemperatureIndexcurrent row of the Temperature sensorro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.9.1.1
netraCtRscTemperatureValidThe current temperature at this sensor is known. If the temperature cannot be obtained, then false will be returned, and netraCtRscTemperatureValue should not be considered to be valid.ro
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.6.9.1.2
netraCtRscTemperatureValuecurrent temperature at this sensorro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.9.1.3
netraCtRscTemperatureLowWarnlow warning threshold for this temperature sensorro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.9.1.4
netraCtRscTemperatureHighWarnhigh warning threshold for this temperature sensorro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.6.9.1.5
netraCtRscTemperatureDesctextual description of the Temperature sensorro
DisplayString ( SIZE
.1.3.6.1.4.1.42.2.65.2.1.6.9.1.6
netraCtRscLogObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.1.7
netraCtRscEventLogCountcurrent number of lines in the event logro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.7.1
netraCtRscEventLogTablea table listing the contents of the event log as an array of strings.
SEQUENCE OF NetraCtRscEventLogEntry
.1.3.6.1.4.1.42.2.65.2.1.7.2
netraCtRscEventLogEntryan entry (conceptual row) in the netraCtRscEventLogTable.
NetraCtRscEventLogEntry
.1.3.6.1.4.1.42.2.65.2.1.7.2.1
netraCtRscEventLogIndexThe index of the entry. The oldest entry will start at index 0. The most recent entry will be found at the index equal to netraCtRscEventLogCount - 1.ro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.7.2.1.1
netraCtRscEventLogTimeStampevent timestampro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.42.2.65.2.1.7.2.1.2
netraCtRscEventLogMessagetextual description of an event.ro
DisplayString ( SIZE
.1.3.6.1.4.1.42.2.65.2.1.7.2.1.3
netraCtRscOrigConsoleLogCountcurrent number of lines in the original console log.ro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.7.3
netraCtRscOrigConsoleLogTablea table listing the contents of the original console log as an array of strings.
SEQUENCE OF NetraCtRscOrigConsoleLogEntry
.1.3.6.1.4.1.42.2.65.2.1.7.4
netraCtRscOrigConsoleLogEntryan entry (conceptual row) in the netraCtRscOrigConsoleLogTable.
NetraCtRscOrigConsoleLogEntry
.1.3.6.1.4.1.42.2.65.2.1.7.4.1
netraCtRscOrigConsoleLogIndexThe index of the entry. The oldest entry will start at index 0. The most recent entry will be found at the index equal to netraCtRscOrigConsoleLogCount - 1.ro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.7.4.1.1
netraCtRscOrigConsoleLogTimeStampOriginal Console Log timestampro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.42.2.65.2.1.7.4.1.2
netraCtRscOrigConsoleLogMessagetextual description of an event.ro
DisplayString ( SIZE
.1.3.6.1.4.1.42.2.65.2.1.7.4.1.3
netraCtRscConsoleLogCountcurrent number of lines in the console log.ro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.7.5
netraCtRscConsoleLogTablea table listing the contents of the console log as an array of strings.
SEQUENCE OF NetraCtRscConsoleLogEntry
.1.3.6.1.4.1.42.2.65.2.1.7.6
netraCtRscConsoleLogEntryan entry (conceptual row) in the netraCtRscConsoleLogTable.
NetraCtRscConsoleLogEntry
.1.3.6.1.4.1.42.2.65.2.1.7.6.1
netraCtRscConsoleLogIndexThe index of the entry. The oldest entry will start at index 0. The most recent entry will be found at the index equal to netraCtRscConsoleLogCount - 1.ro
INTEGER
.1.3.6.1.4.1.42.2.65.2.1.7.6.1.1
netraCtRscConsoleLogTimeStampConsole Log timestampro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.42.2.65.2.1.7.6.1.2
netraCtRscConsoleLogMessagetextual description of an event.ro
DisplayString ( SIZE
.1.3.6.1.4.1.42.2.65.2.1.7.6.1.3
netraCtRscConsoleResetWhen set, the console log is reset so that the current log is copied over to the original console log, and the the console log will be cleared. All new console messages will then go to the console log.clear(2) setting is read-only.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.1.7.7
netraCtRscEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.2
netraCtRscTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.2.0
netraCtRscEventEvent used to notify the snmp manager of a new RSC event. An event is generated when one of the values: netraCtRscAlarmOperState, in the Table:netraCtRscAlarmTable changes state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.42.2.65.2.2.0.1
netraCtRscExpmnt
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.3
netraCtRscRccConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.42.2.65.2.3.1
netraCtRscRCCPowerOnEnableIf set to false, masks the RCC PowerOn command.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.3.1.1
netraCtRscRCCPowerOffEnableIf set to false, masks the RCC PowerOff command.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.3.1.2
netraCtRscRCCResetEnableIf set to false, masks the RCC Reset command.rw
Enumeration
.1.3.6.1.4.1.42.2.65.2.3.1.3
netraCtRscRCCLinkNum2-byte string that defines the RCC Linknum address.rw
DisplayString ( SIZE(2) )
.1.3.6.1.4.1.42.2.65.2.3.1.4
SUN-SNMP-NETRA-CT-RSC-MIB - SNMP MIB Reference | MIBs Explorer