SNMP540-MGMT-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
58
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
58 total| Object Name |
|---|
snmp540 OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4 |
IMPORTS Unknown .1.3.6.1.4.1.498.8.4 |
snmp540MIBversionIdentifies the version of the MIB. The format
of the version is x.yzT, where 'x' identifies
the major revision number, 'y'identifies the
minor revision number, 'z' identifies the
typographical revision, and T identifies the
test revision. Acceptable values for the
individual revision components are
as follows
x: 1 - 9
y: 0 - 9
z: 0 - 9
T: A - Z
Upon formal release, no designation for the test
revision will be present.ro Unknown .1.3.6.1.4.1.498.8.4.1 |
snmp540Config OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.2 |
snmp540ActivateCfgThe Activate configuration object.
The value noChange(1), will maintain the
old dataset configuration without saving any
changes. The value activateNewCfg(2),
will activate the latest changes into
the dataset configuration. No configuration
changes will be activated until
the activateNewCfg(2) is performed. Once
activateNewCfg(2) is sent and acknowledged,
the unit will modify its active configuration.
The unit may temporarily be out of service
until the activate has been completed.
A set using noChange(1) value will cause
the snmp540 to discard all unactivated changes.rw Enumeration .1.3.6.1.4.1.498.8.4.2.1 |
snmp540DtePortTypeThe value auto(3) indicates that the electrical
portion of the DTE interface is automatically
detected. The rs232(1) value forces the DTE port
to EIA/TIA-232-E, and v35(2) will force the DTE
port to V.35.rw Enumeration .1.3.6.1.4.1.498.8.4.2.2 |
snmp540EiaTestControl OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.2.3 |
snmp540EiaRlcontrolThe RL Eia Test control lead option.
This option either allows or blocks EIA
initiated test inputs from the DTE
interface.rw Enumeration .1.3.6.1.4.1.498.8.4.2.3.1 |
snmp540EiaLlcontrolThe LL Eia Test control lead option.
This option either allows or blocks EIA
initiated test inputs from the DTE
interface.rw Enumeration .1.3.6.1.4.1.498.8.4.2.3.2 |
snmp540EiaTmcontrolThe Eia Test Mode lead option.
This option controls the operation of
the Test Mode output indication. A
value of (1) allows the Test Mode
output to indicate the snmp540 is
in a test mode. A value of (2)
will block all Test Mode lead
indications.rw Enumeration .1.3.6.1.4.1.498.8.4.2.3.3 |
snmp540LlbDetectThe Latching Loopback test detect option.
This option controls the operation of
the latching loopback detection. A
value of (1) allows, the latching loopback
test pattern will be detected. A value of (2)
will block the detection of latching loopback
pattern.rw Enumeration .1.3.6.1.4.1.498.8.4.2.3.4 |
snmp540Control OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.3 |
snmp540UnitResetThe value reset(2) will cause the snmp540
to perform a cold start. As soon as the
object has been set to reset(2), the snmp540
will begin its reinitialization. A normal(1)
set request will have no effect.rw Enumeration .1.3.6.1.4.1.498.8.4.3.1 |
snmp540AlarmData OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4 |
snmp540PowerUpAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.1 |
snmp540CfgChkSumErrAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.2 |
snmp540StcLoopbackAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.3 |
snmp540NoNtwkLoopCurrentAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.4 |
snmp540LinePairsReversedAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.5 |
snmp540NoSignalAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.6 |
snmp540FpTestAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.7 |
snmp540DSRLossAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.8 |
snmp540DTRLossAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.9 |
snmp540DTPLossAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.10 |
snmp540DCDLossAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.11 |
snmp540RXDLossAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.12 |
snmp540TXDLossAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.13 |
snmp540JitterAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.14 |
snmp540BpvAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.15 |
snmp540FrameLossAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.16 |
snmp540SignalToNoiseAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.17 |
snmp540RxSignalLowAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.4.18 |
snmp540AlarmCfgThr OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.5 |
snmp540AlarmCfgCountWindowThis is the DDS Alarm Threshold Interval. It
specifies the amount of time, 1 to 15 minutes,
in which the threshold setting is to be exceeded
for the alarm to occur.rw INTEGER .1.3.6.1.4.1.498.8.4.5.1 |
snmp540AlarmCfgTableThe GDC snmp540 Alarm Configuration Table. SEQUENCE OF Snmp540AlarmCfgEntry .1.3.6.1.4.1.498.8.4.5.2 |
snmp540AlarmCfgEntryAn entry in the snmp540 alarm table. Snmp540AlarmCfgEntry .1.3.6.1.4.1.498.8.4.5.2.1 |
snmp540AlarmCfgIdentifierThe unique alarm identifier assigned to this
alarm type. The format of this identifier is
an OBJECT IDENTIFIER that has the following
format: {iso(1) org(3) dod(6) internet(1)
private(4) enterprises(1) gdc(498) xxx(x)
alarm(z) yyy(y) where xxx(x) is the
administratively assigned family object
identifier (z) is the object identifier for
alarms in the family defined MIB and yyy(y)
is the administratively assigned alarm
type identifier for this alarm.ro OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.5.2.1.1 |
snmp540AlarmCfgThresholdThis function sets/reads the alarm threshold
settings criteria. This threshold is used
along with the alarm window to determine
the number of instances in a given time frame
for an alarm to occur before the alarm is
considered active.
Alarm Table Entry Range Default
Jitter snmp540JitterAlm 0 to 99% 10%
BPV's snmp540BpvAlm 0 to 99Count 10
Frm Loss snmp540FrameLossAlm 0 to 99Count 10
SNRatio snmp540SignalToNoiseAlm 0 to 50 0
Rx Low snmp540RxSignalLowAlm -50 to 6db -30dBrw INTEGER (-50..99) .1.3.6.1.4.1.498.8.4.5.2.1.2 |
snmp540LineStats OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.6 |
snmp540LineStatsIntervalThe DDS Line Statistics Interval specifies
the amount of LineStats data to be reported.
Measurements are stored every minute and
accumulated. The latest 15 minutes(samples)
of information are always available.
The LineStatsInterval specifies the number
of one minute sample intervals that will
be accumulated and reported.rw INTEGER .1.3.6.1.4.1.498.8.4.6.1 |
snmp540LineStatsTxLevelTransmit level being generated into the
private line circuit. This value
is typically 6db.ro INTEGER .1.3.6.1.4.1.498.8.4.6.2 |
snmp540LineStatsRxInterpretationThis object the characterizes LineStats readings.
Interpretation code Meaning
..................... ...........................
noSignal(1) No line signal is being received.
notAvailable(2) Data is still being accumulated.
signalToNoiseNotMeasured(3) S/N ratio not measured.
allReadingsValid(4) All data reported is in range.
sToNRatioGreaterThanMeasured(5) S/N ratio (greater)
than the value reported in
SignalToNoiseRatio.ro Enumeration .1.3.6.1.4.1.498.8.4.6.3 |
snmp540LineStatsRxLevelThis object reports the receive level
measurement for the selected interval.
The range reported is from -50dB to +6dB.ro INTEGER (-50..6) .1.3.6.1.4.1.498.8.4.6.4 |
snmp540LineStatsSignalToNoiseRatioThis object will the report the signal to
noise ratio ranging from 0db to 50db for
the selected interval. The value is absolute.
If RxInterpretation reports sToNRatioGreaterThanMeasured,
then the actual signal to noise ratio is better than
the value reported here. If RxInterpretation reports
signalToNoiseNotMeasured, the value reported here
is meaningless.ro INTEGER .1.3.6.1.4.1.498.8.4.6.5 |
snmp540LineStatsSignalQualityThis object reports the signal quality of
the line, for the selected interval.ro Enumeration .1.3.6.1.4.1.498.8.4.6.6 |
snmp540LineStatsJitterThis object will the report the percent jitter
of the line, for the selected interval.ro INTEGER .1.3.6.1.4.1.498.8.4.6.7 |
snmp540LineStatsBpvCountThis object will the report the number of bipolar
violation codes received during for the selected
LineStatsInterval.ro INTEGER .1.3.6.1.4.1.498.8.4.6.8 |
snmp540LineStatsFrameLossCountThis object will the report the number frame
losses received for the selected
LineStatsInterval.ro INTEGER .1.3.6.1.4.1.498.8.4.6.9 |
snmp540DiagTest OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.7 |
snmp540DiagTestPatternThe Self Test Pattern choices generated
internally by the snmp540 are 511 Pattern
(snmp540Send511Pattern(2)), 2047 pattern,
(snmp540Send2047Pattern(3)) and 15 bit pattern,
snmp540Send15BitPattern(4).rw Enumeration .1.3.6.1.4.1.498.8.4.7.1 |
snmp540DiagTestExceptionsIndicates exceptions that have occurred
that may affect interpretation of the
test results.
The exception values are:
value exception:
....... .....................................
1 All test results are valid.
2 snmp540DiagBitErrors has been exceeded.ro Enumeration .1.3.6.1.4.1.498.8.4.7.2 |
snmp540DiagBitErrorsThe bit errors of the most recently run
diagnostic test. If TestExceptions reports
bitsOutOfRange, this object should be ignored.ro INTEGER .1.3.6.1.4.1.498.8.4.7.3 |
snmp540DiagBlockErrorsThe block errors of the most recently run
diagnostic test.ro INTEGER .1.3.6.1.4.1.498.8.4.7.4 |
snmp540RlLoopTypeThe value Pn127(1), will use a PN127 loopback
sequence to initiate a remote loopback test.
The value v54(2) will use a V54 loopback
sequence to initiate a remote loopback test.rw Enumeration .1.3.6.1.4.1.498.8.4.7.5 |
snmp540DiagBlocksToSendSpecifies the number of test pattern blocks to
generate during the test. The requested number
of blocks are sent and checked during the test
as a means of verifying circuit and/or unit
integrity. Each block contains 1000 bits of test
pattern. The external selection specifies that
the test be invoked without any test pattern
block generation. The external(9) disables the
automatic test tear-down timer, and requires the
use of an external Bit Error Rate Tester(BERT).
!!!!!!!!!!! WARNING !!!!!!!!!!!!!!!!!!
THE SNMP540 EXTERNAL(9) TEST SELECTION REQUIRES
A POWER-UP RESET TO END THE TEST !!rw Enumeration .1.3.6.1.4.1.498.8.4.7.6 |
snmp540DiagControlThe lineloop(2) selection places the
snmp540 into line loopback mode. The
noTest(1) and telcoLoop(5) are READ ONLY
values. NoTest(1) indicates that no
diagnostic test is in progress. The
value telcoLoop(5) will be reported
when a DSU/CSU test is initiated by
Telco. The value remoteLoop(3) is used
initiate a remote loopback test. The
value resetTestToNorm(4) will halt the
execution of diagnostic test that may be running.rw Enumeration .1.3.6.1.4.1.498.8.4.7.7 |
snmp540Led OBJECT IDENTIFIER .1.3.6.1.4.1.498.8.4.8 |
snmp540LedStatusReturns a bitwise snapshot of the front panel LED state.
Octet 1 bit 7 - not used
bit 6 - NS
bit 5 - SD
bit 4 - RD
bit 3 - RS
bit 2 - CS
bit 1 - CO
bit 0 - TR
Octet 2 bit 7 - not used
bit 6 - NORM
bit 5 - TEST OK
bit 4 - DBU
bit 3 - CO
bit 2 - DATA
bit 1 - RESP
bit 0 - TEST
::= { snmp540Led 1 }
snmp540DeviceSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
ACCESS read-only
STATUS mandatory
DESCRIPTIONro OCTET STRING .1.3.6.1.4.1.498.8.4.9 |