SL12-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
248
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
248 total| Object Name |
|---|
asentria OBJECT IDENTIFIER .1.3.6.1.4.1.3052 |
RFC1155-SMI Unknown .1.3.6.1.4.1.3052 |
sl12 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41 |
contact1ActiveTrapSent to show Contact 1 is in the alarm state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20001 |
contact2ActiveTrapSent to show Contact 2 is in the alarm state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20002 |
contact3ActiveTrapSent to show Contact 3 is in the alarm state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20003 |
contact4ActiveTrapSent to show Contact 4 is in the alarm state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20004 |
contact5ActiveTrapSent to show Contact 5 is in the alarm state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20005 |
contact6ActiveTrapSent to show Contact 6 is in the alarm state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20006 |
tempHighTrapSent to show Temp exceeded High Temp Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20010 |
tempVeryHighTrapSent to show Temp exceeded Very High Temp Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20011 |
tempLowTrapSent to show Temp went below Low Temp Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20012 |
tempVeryLowTrapSent to show Temp went below Very Low Temp Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20013 |
humidityHighTrapSent to show humidity exceeded High humidity Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20020 |
humidityVeryHighTrapSent to show humidity exceeded Very High humidity Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20021 |
humidityLowTrapSent to show humidity went below Low humidity Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20022 |
humidityVeryLowTrapSent to show humidity went below Very Low humidity Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20023 |
analog1HighTrapSent to show analog1 exceeded High analog1 Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20030 |
analog1VeryHighTrapSent to show analog1 exceeded Very High analog1 Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20031 |
analog1LowTrapSent to show analog1 went below Low analog1 Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20032 |
analog1VeryLowTrapSent to show analog1 went below Very Low analog1 Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20033 |
analog2HighTrapSent to show analog2 exceeded High analog2 Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20040 |
analog2VeryHighTrapSent to show analog2 exceeded Very High analog2 Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20041 |
analog2LowTrapSent to show analog2 went below Low analog2 Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20042 |
analog2VeryLowTrapSent to show analog2 went below Very Low analog2 Threshold TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20043 |
contactESActiveTrapSent to show EventSensor contact is in the alarm state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20101 |
tempESHighTrapSent to show Temp exceeded High Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20110 |
tempESVeryHighTrapSent to show Temp exceeded Very High Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20111 |
tempESLowTrapSent to show Temp went below Low Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20112 |
tempESVeryLowTrapSent to show Temp went below Very Low Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20113 |
humidityESHighTrapSent to show humidity exceeded High Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20120 |
humidityESVeryHighTrapSent to show humidity exceeded Very High Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20121 |
humidityESLowTrapSent to show humidity went below Low Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20122 |
humidityESVeryLowTrapSent to show humidity went below Very Low Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20123 |
voltageESHighTrapSent to show voltage exceeded High Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20130 |
voltageESVeryHighTrapSent to show voltage exceeded Very High Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20131 |
voltageESLowTrapSent to show voltage went below Low Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20132 |
voltageESVeryLowTrapSent to show voltage went below Very Low Threshold on an EventSensor TRAP-TYPE .1.3.6.1.4.1.3052.41.0.20133 |
contact1NormalTrapSent to show Contact 1 is in the normal state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21001 |
contact2NormalTrapSent to show Contact 2 is in the normal state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21002 |
contact3NormalTrapSent to show Contact 3 is in the normal state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21003 |
contact4NormalTrapSent to show Contact 4 is in the normal state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21004 |
contact5NormalTrapSent to show Contact 5 is in the normal state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21005 |
contact6NormalTrapSent to show Contact 6 is in the normal state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21006 |
tempNormalTrapSent to show Temp went back to Normal range TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21010 |
humidityNormalTrapSent to show Humidity went back to Normal range TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21020 |
analog1NormalTrapSent to show analog1 went back to Normal range TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21030 |
analog2NormalTrapSent to show analog2 went back to Normal range TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21040 |
contactESNormalTrapSend to show EventSensor contact has returned to normal state TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21101 |
tempESNormalTrapSent to show EventSensor Temp went back to Normal range TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21110 |
humidityESNormalTrapSent to show EventSensor Humidity went back to Normal range TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21120 |
voltageESNormalTrapSent to show EventSensor voltage went back to Normal range TRAP-TYPE .1.3.6.1.4.1.3052.41.0.21130 |
testTrapSent for testing the SNMP interface TRAP-TYPE .1.3.6.1.4.1.3052.41.0.22000 |
device OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.1 |
serialNumber8-character serial numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.1.1 |
firmwareVersionFirmware version text stringro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.1.2 |
siteIDSite Identifier, up to 12 characters.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.1.3 |
snmpManagerThis is snmp manager #1rwdeprecated IpAddress .1.3.6.1.4.1.3052.41.1.4 |
forceTrapsAny write non-zero forces set of traps to be send to the SNMP Managerrw INTEGER .1.3.6.1.4.1.3052.41.1.6 |
thisTrapTextA text string included in all trapsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.1.7 |
alarmStatusA text status of all alarmsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.1.8 |
snmpManager1SNMP manager #1rw IpAddress .1.3.6.1.4.1.3052.41.1.9 |
snmpManager2SNMP manager #2rw IpAddress .1.3.6.1.4.1.3052.41.1.10 |
snmpManager3SNMP manager #3rw IpAddress .1.3.6.1.4.1.3052.41.1.11 |
snmpManager4SNMP manager #4rw IpAddress .1.3.6.1.4.1.3052.41.1.12 |
statusRepeatHours0=none, 1-24 Number of Hours between Status Traps being Sentrw INTEGER .1.3.6.1.4.1.3052.41.1.13 |
serialTimeout5-30, Minutes of non-activity timeout on serial setuprw INTEGER .1.3.6.1.4.1.3052.41.1.14 |
powerupTrapsend0-no, 1-yes, send traps for all sensors on poweruprw INTEGER .1.3.6.1.4.1.3052.41.1.15 |
netlossTrapsend0-no, 1-yes, send traps for detected netloss and back uprw INTEGER .1.3.6.1.4.1.3052.41.1.16 |
buildID5-chars max text for build identifierro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.1.17 |
contacts OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.2 |
contact1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.2.1 |
contact1NameName for contact, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.2.1.1 |
contact1StateCurrent State of Contact, 0-open 1-closedro INTEGER .1.3.6.1.4.1.3052.41.2.1.2 |
contact1AlarmEnable0-alarms disabled 1-alarms enabledrw INTEGER .1.3.6.1.4.1.3052.41.2.1.3 |
contact1ActiveDirection0-alarm on open 1-alarm on closedrw INTEGER .1.3.6.1.4.1.3052.41.2.1.4 |
contact1ThresholdNumber of seconds that the contact must remain in a state before generating a trap, range 0-255rw INTEGER .1.3.6.1.4.1.3052.41.2.1.5 |
contact1ReturnNormalTrap0-return to normal traps not sent, 1-sentrw INTEGER .1.3.6.1.4.1.3052.41.2.1.6 |
contact1TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm traps.rw INTEGER .1.3.6.1.4.1.3052.41.2.1.7 |
contact1Severity1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.2.1.8 |
contact2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.2.2 |
contact2NameName for contact, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.2.2.1 |
contact2StateCurrent State of Contact, 0-open 1-closedro INTEGER .1.3.6.1.4.1.3052.41.2.2.2 |
contact2AlarmEnable0-no alarms 1-alarms enabledrw INTEGER .1.3.6.1.4.1.3052.41.2.2.3 |
contact2ActiveDirection0-alarm on open 1-alarm on closedrw INTEGER .1.3.6.1.4.1.3052.41.2.2.4 |
contact2ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw INTEGER .1.3.6.1.4.1.3052.41.2.2.5 |
contact2ReturnNormalTrap0-not sent, 1-sentrw INTEGER .1.3.6.1.4.1.3052.41.2.2.6 |
contact2TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm trapsrw INTEGER .1.3.6.1.4.1.3052.41.2.2.7 |
contact2Severity1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.2.2.8 |
contact3 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.2.3 |
contact3NameName for contact, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.2.3.1 |
contact3StateCurrent State of Contact, 0-open 1-closedro INTEGER .1.3.6.1.4.1.3052.41.2.3.2 |
contact3AlarmEnable0-no alarms 1-alarms enabledrw INTEGER .1.3.6.1.4.1.3052.41.2.3.3 |
contact3ActiveDirection0-alarm on open 1-alarm on closedrw INTEGER .1.3.6.1.4.1.3052.41.2.3.4 |
contact3ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw INTEGER .1.3.6.1.4.1.3052.41.2.3.5 |
contact3ReturnNormalTrap0-not sent, 1-sentrw INTEGER .1.3.6.1.4.1.3052.41.2.3.6 |
contact3TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm trapsrw INTEGER .1.3.6.1.4.1.3052.41.2.3.7 |
contact3Severity1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.2.3.8 |
contact4 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.2.4 |
contact4NameName for contact, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.2.4.1 |
contact4StateCurrent State of Contact, 0-open 1-closedro INTEGER .1.3.6.1.4.1.3052.41.2.4.2 |
contact4AlarmEnable0-no alarms 1-alarms enabledrw INTEGER .1.3.6.1.4.1.3052.41.2.4.3 |
contact4ActiveDirection0-alarm on open 1-alarm on closedrw INTEGER .1.3.6.1.4.1.3052.41.2.4.4 |
contact4ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw INTEGER .1.3.6.1.4.1.3052.41.2.4.5 |
contact4ReturnNormalTrap0-not sent, 1-sentrw INTEGER .1.3.6.1.4.1.3052.41.2.4.6 |
contact4TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm trapsrw INTEGER .1.3.6.1.4.1.3052.41.2.4.7 |
contact4Severity1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.2.4.8 |
contact5 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.2.5 |
contact5NameName for contact, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.2.5.1 |
contact5StateCurrent State of Contact, 0-open 1-closedro INTEGER .1.3.6.1.4.1.3052.41.2.5.2 |
contact5AlarmEnable0-no alarms 1-alarms enabledrw INTEGER .1.3.6.1.4.1.3052.41.2.5.3 |
contact5ActiveDirection0-alarm on open 1-alarm on closedrw INTEGER .1.3.6.1.4.1.3052.41.2.5.4 |
contact5ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw INTEGER .1.3.6.1.4.1.3052.41.2.5.5 |
contact5ReturnNormalTrap0-not sent, 1-sentrw INTEGER .1.3.6.1.4.1.3052.41.2.5.6 |
contact5TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm trapsrw INTEGER .1.3.6.1.4.1.3052.41.2.5.7 |
contact5Severity1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.2.5.8 |
contact6 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.2.6 |
contact6NameName for contact, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.2.6.1 |
contact6StateCurrent State of Contact, 0-open 1-closedro INTEGER .1.3.6.1.4.1.3052.41.2.6.2 |
contact6AlarmEnable0-no alarms 1-alarms enabledrw INTEGER .1.3.6.1.4.1.3052.41.2.6.3 |
contact6ActiveDirection0-alarm on open 1-alarm on closedrw INTEGER .1.3.6.1.4.1.3052.41.2.6.4 |
contact6ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw INTEGER .1.3.6.1.4.1.3052.41.2.6.5 |
contact6ReturnNormalTrap0-not sent, 1-sentrw INTEGER .1.3.6.1.4.1.3052.41.2.6.6 |
contact6TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm traps.rw INTEGER .1.3.6.1.4.1.3052.41.2.6.7 |
contact6Severity1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.2.6.8 |
relays OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.3 |
relay1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.3.1 |
relay1NameName for relay, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.3.1.1 |
relay1CurrentState0-opened, 1-closedrw INTEGER .1.3.6.1.4.1.3052.41.3.1.2 |
relay1PowerupState0-opened, 1-closedrw INTEGER .1.3.6.1.4.1.3052.41.3.1.3 |
relay2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.3.2 |
relay2NameName for relay, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.3.2.1 |
relay2CurrentState0-opened, 1-closedrw INTEGER .1.3.6.1.4.1.3052.41.3.2.2 |
relay2PowerupState0-opened, 1-closedrw INTEGER .1.3.6.1.4.1.3052.41.3.2.3 |
tempsensor OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.4 |
tempValueCurrent Temperature Value, in C or F based on 1.3.6.1.4.1.3052.41.4.10ro INTEGER .1.3.6.1.4.1.3052.41.4.1 |
tempAlarmEnable0=alarms disabled, 1=alarms enabledrw INTEGER .1.3.6.1.4.1.3052.41.4.2 |
tempHighLevelLevel at which the High alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.4.3 |
tempVeryHighLevelLevel at which the Very High alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.4.4 |
tempLowLevelLevel at which the Low alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.4.5 |
tempVeryLowLevelLevel at which the Very Low alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.4.6 |
tempAlarmThresholdSeconds must be in a range to be an alarmrw INTEGER .1.3.6.1.4.1.3052.41.4.7 |
tempReturnNormalTrap0-not sent, 1-send trap on return to normal rangerw INTEGER .1.3.6.1.4.1.3052.41.4.8 |
tempTrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm traps.rw INTEGER .1.3.6.1.4.1.3052.41.4.9 |
tempMode0=all temp readings and levels in degrees F, 1=in degrees Crw INTEGER .1.3.6.1.4.1.3052.41.4.10 |
tempHighSeverityHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.4.11 |
tempVeryHighSeverityVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.4.12 |
tempLowSeverityLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.4.13 |
tempVeryLowSeverityVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.4.14 |
tempNameName for temperature sensor, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.4.15 |
humiditysensor OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.5 |
humidityValueCurrent Relative Humidity Value (0-100%)ro INTEGER .1.3.6.1.4.1.3052.41.5.1 |
humidityAlarmEnable0=alarms disabled, 1=alarms enabledrw INTEGER .1.3.6.1.4.1.3052.41.5.2 |
humidityHighLevelLevel at which the High alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.5.3 |
humidityVeryHighLevelLevel at which the Very High alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.5.4 |
humidityLowLevelLevel at which the Low alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.5.5 |
humidityVeryLowLevelLevel at which the Very Low alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.5.6 |
humidityAlarmThresholdSeconds must be in a range to be an alarmrw INTEGER .1.3.6.1.4.1.3052.41.5.7 |
humidityReturnNormalTrap0-not sent, 1-send trap on return to normal rangerw INTEGER .1.3.6.1.4.1.3052.41.5.8 |
humidityTrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm traps.rw INTEGER .1.3.6.1.4.1.3052.41.5.9 |
humidityHighSeverityHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.5.10 |
humidityVeryHighSeverityVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.5.11 |
humidityLowSeverityLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.5.12 |
humidityVeryLowSeverityVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.5.13 |
humidityNameName for humidity sensor, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.5.14 |
passthrough OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.6 |
ptNeedPassword0-no 1-yes, is password required for passthrough connection.rw INTEGER .1.3.6.1.4.1.3052.41.6.1 |
ptSayLoginText0-no 1-yes, is passthrough login text displayed on connection.rw INTEGER .1.3.6.1.4.1.3052.41.6.2 |
ptLoginText0-24 char string which may be displayed on socket connection.
Requires that ptSayLoginText be enabled to display this string.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.6.3 |
ptSaySiteID0-no 1-yes, is SiteID displayed on pass through connection.rw INTEGER .1.3.6.1.4.1.3052.41.6.4 |
ptUsername0-16 char string for Username used in serial passthrough connectionsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.6.5 |
ptPassword0-16 char string for Password used in serial passthrough connectionsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.6.6 |
ptTimeoutnumber of minutes (1-255) of idle activity (both directions) which causes disconnect. 0-neverrw INTEGER .1.3.6.1.4.1.3052.41.6.7 |
ptEscCharASCII character code (e.g, Escape=27) which if entered on the tcp port three times
in a row causes disconnect. 0-nonerw INTEGER .1.3.6.1.4.1.3052.41.6.8 |
ptLfstripToPort0-no 1-yes linefeed characters received on TCP connection are removed from stream to serial portrw INTEGER .1.3.6.1.4.1.3052.41.6.9 |
ptLfstripFromPort0-no 1-yes linefeed characters received on serial port are removed from stream to TCP connectionrw INTEGER .1.3.6.1.4.1.3052.41.6.10 |
ptSerialBaudrate300 600 1200 2400 4800 9600 19200 baud are allowed valuesrw INTEGER .1.3.6.1.4.1.3052.41.6.11 |
ptSerialWordlength7 or 8 bit word selectionrw INTEGER .1.3.6.1.4.1.3052.41.6.12 |
ptSerialParityN E O are allowed values for parity (none, even, odd) [a single-character string]rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.6.13 |
ptTCPPortnumberIP port number for passthrough connection (range 1024-65534)rw INTEGER .1.3.6.1.4.1.3052.41.6.14 |
ftp OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.7 |
ftpUsername0-16 char string for Username used in ftp server for updatesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.7.1 |
ftpPassword0-16 char string for Password used in ftp server for updatesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.7.2 |
analog OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.8 |
analog1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.8.1 |
analog1ValueValue of current analog reading, in 1/100 volt, +- 9999 rangero INTEGER .1.3.6.1.4.1.3052.41.8.1.1 |
analog1AlarmEnable0=no alarms, 1=send alarmsrw INTEGER .1.3.6.1.4.1.3052.41.8.1.2 |
analog1HighLevelLevel at which the High alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.8.1.3 |
analog1VeryHighLevelLevel at which the Very High alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.8.1.4 |
analog1LowLevelLevel at which the Low alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.8.1.5 |
analog1VeryLowLevelLevel at which the Very Low alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.8.1.6 |
analog1AlarmThresholdSeconds must be in a range to be an alarmrw INTEGER .1.3.6.1.4.1.3052.41.8.1.7 |
analog1ReturnNormalTrap0-not sent, 1-send trap on return to normal rangerw INTEGER .1.3.6.1.4.1.3052.41.8.1.8 |
analog1TrapRepeat0-no repeats else number of minutes between repeats of traprw INTEGER .1.3.6.1.4.1.3052.41.8.1.9 |
analog1HighSeverityHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.8.1.10 |
analog1VeryHighSeverityVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.8.1.11 |
analog1LowSeverityLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.8.1.12 |
analog1VeryLowSeverityVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.8.1.13 |
analog1NameName for analog sensor 1, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.8.1.14 |
analog2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.8.2 |
analog2ValueValue of current analog reading, in 1/100 volt, +- 9999 rangero INTEGER .1.3.6.1.4.1.3052.41.8.2.1 |
analog2AlarmEnable0=no alarms, 1=send alarmsrw INTEGER .1.3.6.1.4.1.3052.41.8.2.2 |
analog2HighLevelLevel at which the High alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.8.2.3 |
analog2VeryHighLevelLevel at which the Very High alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.8.2.4 |
analog2LowLevelLevel at which the Low alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.8.2.5 |
analog2VeryLowLevelLevel at which the Very Low alarm goes activerw INTEGER .1.3.6.1.4.1.3052.41.8.2.6 |
analog2AlarmThresholdSeconds must be in a range to be an alarmrw INTEGER .1.3.6.1.4.1.3052.41.8.2.7 |
analog2ReturnNormalTrap0-not sent, 1-send trap on return to normal rangerw INTEGER .1.3.6.1.4.1.3052.41.8.2.8 |
analog2TrapRepeat0-no repeats else number of minutes between repeats of traprw INTEGER .1.3.6.1.4.1.3052.41.8.2.9 |
analog2HighSeverityHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.8.2.10 |
analog2VeryHighSeverityVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.8.2.11 |
analog2LowSeverityLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.8.2.12 |
analog2VeryLowSeverityVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw INTEGER .1.3.6.1.4.1.3052.41.8.2.13 |
analog2NameName for analog sensor 2, up to 30 charactersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.8.2.14 |
eventSensorStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.10 |
esPointTableThis table organizes 4 basic attributes of points. A point
is a particular sensor on an EventSensor (e.g., temperature,
humidity, contact closure 2, relay 5, etc.). The 4 point
attributes are its name, whether it's in its event state,
the point's value as a number and its value as a string.
Points are referenced by a point index. The point index
is a string of 3 numbers separated by periods.
It contains all the information necessary for getting a piece
of data off an event sensor; namely, which EventSensor,
point class, and which-sensor-of-that-class (a.k.a. point). SEQUENCE OF ESPoint .1.3.6.1.4.1.3052.41.10.1 |
esPointEntryEntry for EventSensor point table ESPoint .1.3.6.1.4.1.3052.41.10.1.1 |
esIndexESThe part of the point index that refers to an
EventSensor.
The point index is a string of 3 numbers separated
by periods. It contains all the information
necessary for getting a piece of data off an event
sensor; namely, which EventSensor, point class,
and which-sensor-of-that-class (a.k.a. point).
This object's allowable values are 1 through 4,
which refer to attached EventSensors.
The number corresponding to an EventSensor is
determined by the user at the initial configuration
time. If there is an internal sensor in the unit,
it will always be the first item in the Sensor
Events setup menu.
For example, if a new EventSensor is configured as
the 2nd entry AFTER the internal EventSensor (if
one exists) in the Sensor Events Setup Menu, then
that EventSensor will be known from then on as
EventSensor 2. All point indeces with esIndexES=2
will now refer to that particular EventSensor.ro INTEGER .1.3.6.1.4.1.3052.41.10.1.1.1 |
esIndexPCThe part of the point index that refers to point class.
The point index is a string of 3 numbers separated by periods.
It contains all the information necessary for getting a piece
of data off an event sensor; namely, which EventSensor,
point class, and which-sensor-of-that-class (a.k.a. point).
The values for this object are:
1=temperature sensor
2=contact closure
3=humidity sensor
4=noise sensor
5=analog input
6=relayro INTEGER .1.3.6.1.4.1.3052.41.10.1.1.2 |
esIndexPointThe part of the point index that delineates which
sensor on the EventSensor.
So this combined with esIndexPC (Point Class or type)
and esIndexES (which EventSensor) uniquely defines each
point (sensor or relay) attached to a unit. For
example, if esIndexES is 3, esIndexPC is 1 and
esIndexPoint is 4 then this is the Fourth Temperature
Sensor on EventSensor number 3.ro INTEGER .1.3.6.1.4.1.3052.41.10.1.1.3 |
esPointNameThe name of the point on an EventSensor. For example,
'AC temp' (in the case of the temperature sensor on an
EventSensor).
There can be multiple points of the same point class on an
EventSensor (e.g., 8 contact closures) and multiple sensor
classes on an EventSensor (e.g., temperature, contact closure,
humidity).
If the point referenced by a given point index is solitary
(e.g., temperature sensor, because there can be only one on
an EventSensor), then this object reads as '<EventSensor
name>'. Setting this object for solitary point indices sets
the EventSensor name only.
On the other hand, if a given point is among other points of
the same point class on an EventSensor, then this object reads
as '<Sensor name>'. Setting this object for these NON-
solitary point indices sets the sensor name only - not the
EventSensor name.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.10.1.1.4 |
esPointInEventStateA number referring to the event state of a point
on an EventSensor. This number can have different
meanings depending on the point class.
If the point class is temperature, humidity, or
analog input, then the values of this object are:
1=very low
2=low
3=normal
4=high
5=very high
For contact closures and relays the values of this
object are:
1=point in event state
2=point in normal state
For any point class and any point, if the event
state is undefined, then the value of this object
is 0.
For any point class except relay, this object is
read-only. For relays, setting this object to 1
puts the relay into its open state.
Setting it to 2 puts the relay into its closed
state.rw INTEGER .1.3.6.1.4.1.3052.41.10.1.1.5 |
esPointValueIntA number referring to the value of a point on an
EventSensor.
If the point class is temperature, then this object
is the temperature in its configured scale (default
is Fahrenheit).
If the point class is contact closure or relay, then
this object is either 0 (open) or 1 (closed).
If the point class is humidity, then this object
is the percent relative humidity.
If the point class is analog input, then this
object is the signed input value in tenths of the
configured units.
For any point class except relay, this object is
read-only. For relays, setting this object to 1
closes the relay, while setting it to 0 opens it.
This works regardless of the control mode of the
relay.rw INTEGER (-32768..32767) .1.3.6.1.4.1.3052.41.10.1.1.6 |
esPointValueStrA string referring to the value of a point on an
EventSensor.
For contact closures and relays this object is
either 'Open' or 'Closed'.
For temperature and humidity point classes, this
object is the string representation of the
esPointValueInt object. For temperature, 'C' or
'F' is including in the string to indicate scale.
For analog inputs, this object is the string
representation of the plus/minus input in volts.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.10.1.1.7 |
eventSensorConfig OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.11 |
esNumberEventSensorsThe number of EventSensors recognized by the SL12
Range: 0-4ro INTEGER .1.3.6.1.4.1.3052.41.11.1 |
esTableThe table of what EventSensors are attached to the unit SEQUENCE OF ESExist .1.3.6.1.4.1.3052.41.11.2 |
esEntryTable entry for EventSensor table ESExist .1.3.6.1.4.1.3052.41.11.2.1 |
esIndexThis number refers to an EventSensor; it has the
same meaning as the esIndexES object (see above),
except that this object is used only within the
esTable branch.
This object's allowable values are 1 through 4,
which refer to additional attached EventSensors.
The number corresponding to an EventSensor is
determined by the user at the initial configuration
time.ro INTEGER .1.3.6.1.4.1.3052.41.11.2.1.1 |
esIDThe factory-assigned ID of the EventSensorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.11.2.1.2 |
esNumberTempSensorsThe number of temperature sensors on the EventSensorro INTEGER .1.3.6.1.4.1.3052.41.11.2.1.3 |
esTempReportingModeDescription of how temperature values should
be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.11.2.1.4 |
esNumberCCsThe number of contact closures on the EventSensor.ro INTEGER .1.3.6.1.4.1.3052.41.11.2.1.5 |
esCCReportingModeDescription of how CC values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.11.2.1.6 |
esNumberHumidSensorsThe number of humidity sensors on the EventSensor.ro INTEGER .1.3.6.1.4.1.3052.41.11.2.1.7 |
esHumidReportingModeDescription of how humidity sensor values should be
interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.11.2.1.8 |
esNumberAnalogThe number of analog inputs on the EventSensor.ro INTEGER .1.3.6.1.4.1.3052.41.11.2.1.13 |
esAnalogReportingModeDescription of how analog input values should be
interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.11.2.1.14 |
esNumberRelayOutputsThe number of relay outputs on the EventSensorro INTEGER .1.3.6.1.4.1.3052.41.11.2.1.15 |
esRelayReportingModeDescription of how relay output values
should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.11.2.1.16 |
techsupport OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.99 |
techsupportIPAddressMay read or Set IP Address, takes effect on restartrw IpAddress .1.3.6.1.4.1.3052.41.99.1 |
techsupportNetMaskMay read or Set NetMask, takes effect on restartrw IpAddress .1.3.6.1.4.1.3052.41.99.2 |
techsupportRouterMay read or Set Router IP Address, takes effect on restartrw IpAddress .1.3.6.1.4.1.3052.41.99.3 |
techsupportRestartReads as 0, any Write resets unit so new IP, Netmask, Router may be usedrw INTEGER .1.3.6.1.4.1.3052.41.99.4 |
techsupportVersionNumberVersion Number of Firmwarerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.41.99.5 |
mibend OBJECT IDENTIFIER .1.3.6.1.4.1.3052.41.100 |
mibendObjectAn object after all active mib items, to help some managers compilero INTEGER .1.3.6.1.4.1.3052.41.100.1 |