SITEBOSS-450-STD-MIB
MIB module for managing Asentria SiteBoss 450
Main OID:
s450.1.3.6.1.4.1.3052.17
1490
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
1490 total| Object Name |
|---|
s450MIB module for managing Asentria SiteBoss 450 MODULE-IDENTITY .1.3.6.1.4.1.3052.17 |
s450notifications OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.0 |
s450StockContactClosureTrapA stock contact closure trap is issued when a contact closure event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.110 |
s450StockTempTrapA stock temperature trap is issued when a temperature event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.120 |
s450StockHumidityTrapA stock humidity trap is issued when a humidity event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.130 |
s450StockAnalogTrapA stock analog trap is issued when an analog sensor event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.140 |
s450StockOutputTrapA stock output trap is issued when an output event happens. That is, depending on the configuration, when an output changes state for any reason, this trap will be sent. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.150 |
s450StockSchedTrapThe stock scheduled alarm trap is issued when the current time reaches the scheduled alarm time. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.506 |
s450StockImmediateTrapThe stock immediate alarm trap is issued when the user enters the DOTRAP command. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.507 |
s450StockCTSTrapA stock CTS trap is issued when an RS-232 CTS event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.510 |
s450CPEDownTrapA stock CPE Down trap is issued when a CPE Down event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.511 |
s450FuelSensorDisconnectTrapA stock Fuel Sensor Disconnect trap is issued when a Fuel Sensor Disconnect or Connect (Return to Normal) event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.515 |
s450FuelSensorVolumeTrapA stock Fuel Sensor Volume trap is issued when a Fuel Sensor Volume event happens NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.519 |
s450ACPowerMonitorAvgVoltageTrapA stock AC power monitor average voltage trap is issued when an AC power monitor average voltage event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.520 |
s450ACPowerMonitorAvgCurrentTrapA stock AC power monitor average current trap is issued when an AC power monitor average current event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.521 |
s450ACPowerMonitorFrequencyTrapA stock AC power monitor frequency trap is issued when an AC power monitor frequency event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.522 |
s450ACPowerMonitorTRPTrapA stock AC power monitor TRP (total real power) trap is issued when an AC power monitor TRP event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.523 |
s450ACPowerMonitorDisconnectTrapA stock AC power monitor disconnect trap is issued when an AC power monitor disconnect event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.524 |
s450StockScriptTrapA stock script trap is issued when a script triggers an event via a_lib.PostEvent() called with no trap number (or this trap number) specified. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.526 |
s450FuelSensorVolumeSuddenChangeTrapA stock Fuel Sensor Volume Sudden Change trap is issued when a Fuel Sensor Volume Sudden Change event happens NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.527 |
s450FuelSensorVolumeSlowChangeTrapA stock Fuel Sensor Volume Slow Change trap is issued when a Fuel Sensor Volume Slow Change event happens NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.528 |
s450BattMonStringTemperatureTrapA stock Battery Monitor String Temperature trap is issued when a Battery Monitor String Temperature event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.530 |
s450BattMonStringDiffTemperatureTrapA stock Battery Monitor String Differential Temperature trap is issued when a Battery Monitor String Differential Temperature event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.531 |
s450BattMonStringVoltageTrapA stock Battery Monitor String Voltage trap is issued when a Battery Monitor String Voltage event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.532 |
s450BattMonStringChargeLevelTrapA stock Battery Monitor String Charge Level trap is issued when a Battery Monitor String Charge Level event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.533 |
s450BattMonStringChargingCurrentTrapA stock Battery Monitor String Charging Current trap is issued when a Battery Monitor String Charging Current event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.534 |
s450BattMonStringDischargingCurrentTrapA stock Battery Monitor String Discharging Current trap is issued when a Battery Monitor String Discharging Current event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.535 |
s450GeneratorNonStartTrapA stock Generator Non-start trap is issued when the unit commands the generator to start as part of the generator exercising feature, and the generator fails to register as started after 30 seconds (as detected by CC generator running detection). NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.536 |
s450BattMonStringDifferentialVoltageTrapA stock Battery Monitor String Differential Voltage trap is issued when a Battery Monitor String Differential Voltage event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.537 |
s450BattMonStringJarHealthTrapA stock Battery Monitor String Jar Health trap is issued when a Battery Monitor String Jar Health event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.538 |
s450CameraTrapA stock camera trap is issued when a camera event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.539 |
s450ACTotalPowerFactorTrapA stock AC power monitor total power factor trap is issued when an AC power monitor total power factor event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.540 |
s450ResetTrapA stock reset trap is issued when a reset event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.543 |
s450UserTrap1000This user-defined trap is issued when an event happens that causes a trap with specific trap type 1000. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1000 |
s450UserTrap1001This user-defined trap is issued when an event happens that causes a trap with specific trap type 1001. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1001 |
s450UserTrap1002This user-defined trap is issued when an event happens that causes a trap with specific trap type 1002. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1002 |
s450UserTrap1003This user-defined trap is issued when an event happens that causes a trap with specific trap type 1003. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1003 |
s450UserTrap1004This user-defined trap is issued when an event happens that causes a trap with specific trap type 1004. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1004 |
s450UserTrap1005This user-defined trap is issued when an event happens that causes a trap with specific trap type 1005. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1005 |
s450UserTrap1006This user-defined trap is issued when an event happens that causes a trap with specific trap type 1006. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1006 |
s450UserTrap1007This user-defined trap is issued when an event happens that causes a trap with specific trap type 1007. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1007 |
s450UserTrap1008This user-defined trap is issued when an event happens that causes a trap with specific trap type 1008. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1008 |
s450UserTrap1009This user-defined trap is issued when an event happens that causes a trap with specific trap type 1009. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1009 |
s450UserTrap1010This user-defined trap is issued when an event happens that causes a trap with specific trap type 1010. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1010 |
s450UserTrap1011This user-defined trap is issued when an event happens that causes a trap with specific trap type 1011. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1011 |
s450UserTrap1012This user-defined trap is issued when an event happens that causes a trap with specific trap type 1012. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1012 |
s450UserTrap1013This user-defined trap is issued when an event happens that causes a trap with specific trap type 1013. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1013 |
s450UserTrap1014This user-defined trap is issued when an event happens that causes a trap with specific trap type 1014. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1014 |
s450UserTrap1015This user-defined trap is issued when an event happens that causes a trap with specific trap type 1015. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1015 |
s450UserTrap1016This user-defined trap is issued when an event happens that causes a trap with specific trap type 1016. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1016 |
s450UserTrap1017This user-defined trap is issued when an event happens that causes a trap with specific trap type 1017. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1017 |
s450UserTrap1018This user-defined trap is issued when an event happens that causes a trap with specific trap type 1018. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1018 |
s450UserTrap1019This user-defined trap is issued when an event happens that causes a trap with specific trap type 1019. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1019 |
s450UserTrap1020This user-defined trap is issued when an event happens that causes a trap with specific trap type 1020. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1020 |
s450UserTrap1021This user-defined trap is issued when an event happens that causes a trap with specific trap type 1021. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1021 |
s450UserTrap1022This user-defined trap is issued when an event happens that causes a trap with specific trap type 1022. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1022 |
s450UserTrap1023This user-defined trap is issued when an event happens that causes a trap with specific trap type 1023. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1023 |
s450UserTrap1024This user-defined trap is issued when an event happens that causes a trap with specific trap type 1024. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1024 |
s450UserTrap1025This user-defined trap is issued when an event happens that causes a trap with specific trap type 1025. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1025 |
s450UserTrap1026This user-defined trap is issued when an event happens that causes a trap with specific trap type 1026. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1026 |
s450UserTrap1027This user-defined trap is issued when an event happens that causes a trap with specific trap type 1027. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1027 |
s450UserTrap1028This user-defined trap is issued when an event happens that causes a trap with specific trap type 1028. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1028 |
s450UserTrap1029This user-defined trap is issued when an event happens that causes a trap with specific trap type 1029. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1029 |
s450UserTrap1030This user-defined trap is issued when an event happens that causes a trap with specific trap type 1030. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1030 |
s450UserTrap1031This user-defined trap is issued when an event happens that causes a trap with specific trap type 1031. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1031 |
s450UserTrap1032This user-defined trap is issued when an event happens that causes a trap with specific trap type 1032. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1032 |
s450UserTrap1033This user-defined trap is issued when an event happens that causes a trap with specific trap type 1033. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1033 |
s450UserTrap1034This user-defined trap is issued when an event happens that causes a trap with specific trap type 1034. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1034 |
s450UserTrap1035This user-defined trap is issued when an event happens that causes a trap with specific trap type 1035. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1035 |
s450UserTrap1036This user-defined trap is issued when an event happens that causes a trap with specific trap type 1036. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1036 |
s450UserTrap1037This user-defined trap is issued when an event happens that causes a trap with specific trap type 1037. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1037 |
s450UserTrap1038This user-defined trap is issued when an event happens that causes a trap with specific trap type 1038. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1038 |
s450UserTrap1039This user-defined trap is issued when an event happens that causes a trap with specific trap type 1039. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1039 |
s450UserTrap1040This user-defined trap is issued when an event happens that causes a trap with specific trap type 1040. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1040 |
s450UserTrap1041This user-defined trap is issued when an event happens that causes a trap with specific trap type 1041. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1041 |
s450UserTrap1042This user-defined trap is issued when an event happens that causes a trap with specific trap type 1042. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1042 |
s450UserTrap1043This user-defined trap is issued when an event happens that causes a trap with specific trap type 1043. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1043 |
s450UserTrap1044This user-defined trap is issued when an event happens that causes a trap with specific trap type 1044. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1044 |
s450UserTrap1045This user-defined trap is issued when an event happens that causes a trap with specific trap type 1045. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1045 |
s450UserTrap1046This user-defined trap is issued when an event happens that causes a trap with specific trap type 1046. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1046 |
s450UserTrap1047This user-defined trap is issued when an event happens that causes a trap with specific trap type 1047. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1047 |
s450UserTrap1048This user-defined trap is issued when an event happens that causes a trap with specific trap type 1048. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1048 |
s450UserTrap1049This user-defined trap is issued when an event happens that causes a trap with specific trap type 1049. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1049 |
s450UserTrap1050This user-defined trap is issued when an event happens that causes a trap with specific trap type 1050. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1050 |
s450UserTrap1051This user-defined trap is issued when an event happens that causes a trap with specific trap type 1051. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1051 |
s450UserTrap1052This user-defined trap is issued when an event happens that causes a trap with specific trap type 1052. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1052 |
s450UserTrap1053This user-defined trap is issued when an event happens that causes a trap with specific trap type 1053. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1053 |
s450UserTrap1054This user-defined trap is issued when an event happens that causes a trap with specific trap type 1054. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1054 |
s450UserTrap1055This user-defined trap is issued when an event happens that causes a trap with specific trap type 1055. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1055 |
s450UserTrap1056This user-defined trap is issued when an event happens that causes a trap with specific trap type 1056. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1056 |
s450UserTrap1057This user-defined trap is issued when an event happens that causes a trap with specific trap type 1057. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1057 |
s450UserTrap1058This user-defined trap is issued when an event happens that causes a trap with specific trap type 1058. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1058 |
s450UserTrap1059This user-defined trap is issued when an event happens that causes a trap with specific trap type 1059. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1059 |
s450UserTrap1060This user-defined trap is issued when an event happens that causes a trap with specific trap type 1060. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1060 |
s450UserTrap1061This user-defined trap is issued when an event happens that causes a trap with specific trap type 1061. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1061 |
s450UserTrap1062This user-defined trap is issued when an event happens that causes a trap with specific trap type 1062. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1062 |
s450UserTrap1063This user-defined trap is issued when an event happens that causes a trap with specific trap type 1063. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1063 |
s450UserTrap1064This user-defined trap is issued when an event happens that causes a trap with specific trap type 1064. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1064 |
s450UserTrap1065This user-defined trap is issued when an event happens that causes a trap with specific trap type 1065. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1065 |
s450UserTrap1066This user-defined trap is issued when an event happens that causes a trap with specific trap type 1066. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1066 |
s450UserTrap1067This user-defined trap is issued when an event happens that causes a trap with specific trap type 1067. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1067 |
s450UserTrap1068This user-defined trap is issued when an event happens that causes a trap with specific trap type 1068. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1068 |
s450UserTrap1069This user-defined trap is issued when an event happens that causes a trap with specific trap type 1069. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1069 |
s450UserTrap1070This user-defined trap is issued when an event happens that causes a trap with specific trap type 1070. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1070 |
s450UserTrap1071This user-defined trap is issued when an event happens that causes a trap with specific trap type 1071. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1071 |
s450UserTrap1072This user-defined trap is issued when an event happens that causes a trap with specific trap type 1072. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1072 |
s450UserTrap1073This user-defined trap is issued when an event happens that causes a trap with specific trap type 1073. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1073 |
s450UserTrap1074This user-defined trap is issued when an event happens that causes a trap with specific trap type 1074. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1074 |
s450UserTrap1075This user-defined trap is issued when an event happens that causes a trap with specific trap type 1075. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1075 |
s450UserTrap1076This user-defined trap is issued when an event happens that causes a trap with specific trap type 1076. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1076 |
s450UserTrap1077This user-defined trap is issued when an event happens that causes a trap with specific trap type 1077. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1077 |
s450UserTrap1078This user-defined trap is issued when an event happens that causes a trap with specific trap type 1078. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1078 |
s450UserTrap1079This user-defined trap is issued when an event happens that causes a trap with specific trap type 1079. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1079 |
s450UserTrap1080This user-defined trap is issued when an event happens that causes a trap with specific trap type 1080. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1080 |
s450UserTrap1081This user-defined trap is issued when an event happens that causes a trap with specific trap type 1081. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1081 |
s450UserTrap1082This user-defined trap is issued when an event happens that causes a trap with specific trap type 1082. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1082 |
s450UserTrap1083This user-defined trap is issued when an event happens that causes a trap with specific trap type 1083. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1083 |
s450UserTrap1084This user-defined trap is issued when an event happens that causes a trap with specific trap type 1084. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1084 |
s450UserTrap1085This user-defined trap is issued when an event happens that causes a trap with specific trap type 1085. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1085 |
s450UserTrap1086This user-defined trap is issued when an event happens that causes a trap with specific trap type 1086. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1086 |
s450UserTrap1087This user-defined trap is issued when an event happens that causes a trap with specific trap type 1087. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1087 |
s450UserTrap1088This user-defined trap is issued when an event happens that causes a trap with specific trap type 1088. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1088 |
s450UserTrap1089This user-defined trap is issued when an event happens that causes a trap with specific trap type 1089. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1089 |
s450UserTrap1090This user-defined trap is issued when an event happens that causes a trap with specific trap type 1090. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1090 |
s450UserTrap1091This user-defined trap is issued when an event happens that causes a trap with specific trap type 1091. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1091 |
s450UserTrap1092This user-defined trap is issued when an event happens that causes a trap with specific trap type 1092. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1092 |
s450UserTrap1093This user-defined trap is issued when an event happens that causes a trap with specific trap type 1093. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1093 |
s450UserTrap1094This user-defined trap is issued when an event happens that causes a trap with specific trap type 1094. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1094 |
s450UserTrap1095This user-defined trap is issued when an event happens that causes a trap with specific trap type 1095. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1095 |
s450UserTrap1096This user-defined trap is issued when an event happens that causes a trap with specific trap type 1096. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1096 |
s450UserTrap1097This user-defined trap is issued when an event happens that causes a trap with specific trap type 1097. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1097 |
s450UserTrap1098This user-defined trap is issued when an event happens that causes a trap with specific trap type 1098. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1098 |
s450UserTrap1099This user-defined trap is issued when an event happens that causes a trap with specific trap type 1099. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1099 |
s450UserTrap1100This user-defined trap is issued when an event happens that causes a trap with specific trap type 1100. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1100 |
s450UserTrap1101This user-defined trap is issued when an event happens that causes a trap with specific trap type 1101. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1101 |
s450UserTrap1102This user-defined trap is issued when an event happens that causes a trap with specific trap type 1102. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1102 |
s450UserTrap1103This user-defined trap is issued when an event happens that causes a trap with specific trap type 1103. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1103 |
s450UserTrap1104This user-defined trap is issued when an event happens that causes a trap with specific trap type 1104. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1104 |
s450UserTrap1105This user-defined trap is issued when an event happens that causes a trap with specific trap type 1105. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1105 |
s450UserTrap1106This user-defined trap is issued when an event happens that causes a trap with specific trap type 1106. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1106 |
s450UserTrap1107This user-defined trap is issued when an event happens that causes a trap with specific trap type 1107. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1107 |
s450UserTrap1108This user-defined trap is issued when an event happens that causes a trap with specific trap type 1108. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1108 |
s450UserTrap1109This user-defined trap is issued when an event happens that causes a trap with specific trap type 1109. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1109 |
s450UserTrap1110This user-defined trap is issued when an event happens that causes a trap with specific trap type 1110. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1110 |
s450UserTrap1111This user-defined trap is issued when an event happens that causes a trap with specific trap type 1111. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1111 |
s450UserTrap1112This user-defined trap is issued when an event happens that causes a trap with specific trap type 1112. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1112 |
s450UserTrap1113This user-defined trap is issued when an event happens that causes a trap with specific trap type 1113. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1113 |
s450UserTrap1114This user-defined trap is issued when an event happens that causes a trap with specific trap type 1114. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1114 |
s450UserTrap1115This user-defined trap is issued when an event happens that causes a trap with specific trap type 1115. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1115 |
s450UserTrap1116This user-defined trap is issued when an event happens that causes a trap with specific trap type 1116. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1116 |
s450UserTrap1117This user-defined trap is issued when an event happens that causes a trap with specific trap type 1117. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1117 |
s450UserTrap1118This user-defined trap is issued when an event happens that causes a trap with specific trap type 1118. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1118 |
s450UserTrap1119This user-defined trap is issued when an event happens that causes a trap with specific trap type 1119. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1119 |
s450UserTrap1120This user-defined trap is issued when an event happens that causes a trap with specific trap type 1120. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1120 |
s450UserTrap1121This user-defined trap is issued when an event happens that causes a trap with specific trap type 1121. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1121 |
s450UserTrap1122This user-defined trap is issued when an event happens that causes a trap with specific trap type 1122. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1122 |
s450UserTrap1123This user-defined trap is issued when an event happens that causes a trap with specific trap type 1123. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1123 |
s450UserTrap1124This user-defined trap is issued when an event happens that causes a trap with specific trap type 1124. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1124 |
s450UserTrap1125This user-defined trap is issued when an event happens that causes a trap with specific trap type 1125. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1125 |
s450UserTrap1126This user-defined trap is issued when an event happens that causes a trap with specific trap type 1126. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1126 |
s450UserTrap1127This user-defined trap is issued when an event happens that causes a trap with specific trap type 1127. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1127 |
s450UserTrap1128This user-defined trap is issued when an event happens that causes a trap with specific trap type 1128. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1128 |
s450UserTrap1129This user-defined trap is issued when an event happens that causes a trap with specific trap type 1129. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1129 |
s450UserTrap1130This user-defined trap is issued when an event happens that causes a trap with specific trap type 1130. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1130 |
s450UserTrap1131This user-defined trap is issued when an event happens that causes a trap with specific trap type 1131. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1131 |
s450UserTrap1132This user-defined trap is issued when an event happens that causes a trap with specific trap type 1132. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1132 |
s450UserTrap1133This user-defined trap is issued when an event happens that causes a trap with specific trap type 1133. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1133 |
s450UserTrap1134This user-defined trap is issued when an event happens that causes a trap with specific trap type 1134. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1134 |
s450UserTrap1135This user-defined trap is issued when an event happens that causes a trap with specific trap type 1135. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1135 |
s450UserTrap1136This user-defined trap is issued when an event happens that causes a trap with specific trap type 1136. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1136 |
s450UserTrap1137This user-defined trap is issued when an event happens that causes a trap with specific trap type 1137. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1137 |
s450UserTrap1138This user-defined trap is issued when an event happens that causes a trap with specific trap type 1138. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1138 |
s450UserTrap1139This user-defined trap is issued when an event happens that causes a trap with specific trap type 1139. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1139 |
s450UserTrap1140This user-defined trap is issued when an event happens that causes a trap with specific trap type 1140. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1140 |
s450UserTrap1141This user-defined trap is issued when an event happens that causes a trap with specific trap type 1141. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1141 |
s450UserTrap1142This user-defined trap is issued when an event happens that causes a trap with specific trap type 1142. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1142 |
s450UserTrap1143This user-defined trap is issued when an event happens that causes a trap with specific trap type 1143. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1143 |
s450UserTrap1144This user-defined trap is issued when an event happens that causes a trap with specific trap type 1144. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1144 |
s450UserTrap1145This user-defined trap is issued when an event happens that causes a trap with specific trap type 1145. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1145 |
s450UserTrap1146This user-defined trap is issued when an event happens that causes a trap with specific trap type 1146. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1146 |
s450UserTrap1147This user-defined trap is issued when an event happens that causes a trap with specific trap type 1147. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1147 |
s450UserTrap1148This user-defined trap is issued when an event happens that causes a trap with specific trap type 1148. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1148 |
s450UserTrap1149This user-defined trap is issued when an event happens that causes a trap with specific trap type 1149. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1149 |
s450UserTrap1150This user-defined trap is issued when an event happens that causes a trap with specific trap type 1150. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1150 |
s450UserTrap1151This user-defined trap is issued when an event happens that causes a trap with specific trap type 1151. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1151 |
s450UserTrap1152This user-defined trap is issued when an event happens that causes a trap with specific trap type 1152. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1152 |
s450UserTrap1153This user-defined trap is issued when an event happens that causes a trap with specific trap type 1153. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1153 |
s450UserTrap1154This user-defined trap is issued when an event happens that causes a trap with specific trap type 1154. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1154 |
s450UserTrap1155This user-defined trap is issued when an event happens that causes a trap with specific trap type 1155. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1155 |
s450UserTrap1156This user-defined trap is issued when an event happens that causes a trap with specific trap type 1156. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1156 |
s450UserTrap1157This user-defined trap is issued when an event happens that causes a trap with specific trap type 1157. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1157 |
s450UserTrap1158This user-defined trap is issued when an event happens that causes a trap with specific trap type 1158. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1158 |
s450UserTrap1159This user-defined trap is issued when an event happens that causes a trap with specific trap type 1159. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1159 |
s450UserTrap1160This user-defined trap is issued when an event happens that causes a trap with specific trap type 1160. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1160 |
s450UserTrap1161This user-defined trap is issued when an event happens that causes a trap with specific trap type 1161. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1161 |
s450UserTrap1162This user-defined trap is issued when an event happens that causes a trap with specific trap type 1162. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1162 |
s450UserTrap1163This user-defined trap is issued when an event happens that causes a trap with specific trap type 1163. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1163 |
s450UserTrap1164This user-defined trap is issued when an event happens that causes a trap with specific trap type 1164. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1164 |
s450UserTrap1165This user-defined trap is issued when an event happens that causes a trap with specific trap type 1165. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1165 |
s450UserTrap1166This user-defined trap is issued when an event happens that causes a trap with specific trap type 1166. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1166 |
s450UserTrap1167This user-defined trap is issued when an event happens that causes a trap with specific trap type 1167. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1167 |
s450UserTrap1168This user-defined trap is issued when an event happens that causes a trap with specific trap type 1168. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1168 |
s450UserTrap1169This user-defined trap is issued when an event happens that causes a trap with specific trap type 1169. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1169 |
s450UserTrap1170This user-defined trap is issued when an event happens that causes a trap with specific trap type 1170. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1170 |
s450UserTrap1171This user-defined trap is issued when an event happens that causes a trap with specific trap type 1171. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1171 |
s450UserTrap1172This user-defined trap is issued when an event happens that causes a trap with specific trap type 1172. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1172 |
s450UserTrap1173This user-defined trap is issued when an event happens that causes a trap with specific trap type 1173. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1173 |
s450UserTrap1174This user-defined trap is issued when an event happens that causes a trap with specific trap type 1174. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1174 |
s450UserTrap1175This user-defined trap is issued when an event happens that causes a trap with specific trap type 1175. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1175 |
s450UserTrap1176This user-defined trap is issued when an event happens that causes a trap with specific trap type 1176. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1176 |
s450UserTrap1177This user-defined trap is issued when an event happens that causes a trap with specific trap type 1177. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1177 |
s450UserTrap1178This user-defined trap is issued when an event happens that causes a trap with specific trap type 1178. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1178 |
s450UserTrap1179This user-defined trap is issued when an event happens that causes a trap with specific trap type 1179. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1179 |
s450UserTrap1180This user-defined trap is issued when an event happens that causes a trap with specific trap type 1180. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1180 |
s450UserTrap1181This user-defined trap is issued when an event happens that causes a trap with specific trap type 1181. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1181 |
s450UserTrap1182This user-defined trap is issued when an event happens that causes a trap with specific trap type 1182. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1182 |
s450UserTrap1183This user-defined trap is issued when an event happens that causes a trap with specific trap type 1183. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1183 |
s450UserTrap1184This user-defined trap is issued when an event happens that causes a trap with specific trap type 1184. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1184 |
s450UserTrap1185This user-defined trap is issued when an event happens that causes a trap with specific trap type 1185. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1185 |
s450UserTrap1186This user-defined trap is issued when an event happens that causes a trap with specific trap type 1186. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1186 |
s450UserTrap1187This user-defined trap is issued when an event happens that causes a trap with specific trap type 1187. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1187 |
s450UserTrap1188This user-defined trap is issued when an event happens that causes a trap with specific trap type 1188. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1188 |
s450UserTrap1189This user-defined trap is issued when an event happens that causes a trap with specific trap type 1189. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1189 |
s450UserTrap1190This user-defined trap is issued when an event happens that causes a trap with specific trap type 1190. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1190 |
s450UserTrap1191This user-defined trap is issued when an event happens that causes a trap with specific trap type 1191. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1191 |
s450UserTrap1192This user-defined trap is issued when an event happens that causes a trap with specific trap type 1192. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1192 |
s450UserTrap1193This user-defined trap is issued when an event happens that causes a trap with specific trap type 1193. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1193 |
s450UserTrap1194This user-defined trap is issued when an event happens that causes a trap with specific trap type 1194. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1194 |
s450UserTrap1195This user-defined trap is issued when an event happens that causes a trap with specific trap type 1195. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1195 |
s450UserTrap1196This user-defined trap is issued when an event happens that causes a trap with specific trap type 1196. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1196 |
s450UserTrap1197This user-defined trap is issued when an event happens that causes a trap with specific trap type 1197. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1197 |
s450UserTrap1198This user-defined trap is issued when an event happens that causes a trap with specific trap type 1198. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1198 |
s450UserTrap1199This user-defined trap is issued when an event happens that causes a trap with specific trap type 1199. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.17.0.1199 |
status OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.1 |
eventSensorStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.1.1 |
esPointTableThis table organizes 4 basic attributes of points. A point is a particular sensor on an EventSensor (e.g., temperature, humidity, contact closure 2, relay 5, etc.). The 4 point attributes are its name, whether it's in its event state, the point's value as a number and its value as a string. Points are referenced by a point index. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). SEQUENCE OF ESPoint .1.3.6.1.4.1.3052.17.1.1.1 |
esPointEntryEntry for EventSensor point table ESPoint .1.3.6.1.4.1.3052.17.1.1.1.1 |
esIndexESThe part of the point index that refers to an EventSensor. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndexES=2 will now refer to that particular EventSensor.ro Integer32 .1.3.6.1.4.1.3052.17.1.1.1.1.1 |
esIndexPCThe part of the point index that refers to point class. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). The values for this object are: 1=temperature sensor 2=contact closure 3=humidity sensor 4=noise sensor 5=analog input 6=relayro Integer32 .1.3.6.1.4.1.3052.17.1.1.1.1.2 |
esIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with esIndexPC (Point Class or type) and esIndexES (which EventSensor) uniquely defines each point (sensor or relay) attached to a unit. For example, if esIndexES is 3, esIndexPC is 1 and esIndexPoint is 4 then this is the Fourth Temperature Sensor on EventSensor number 3.ro Integer32 .1.3.6.1.4.1.3052.17.1.1.1.1.3 |
esPointNameThe name of the point on an EventSensor. For example, 'AC temp' (in the case of the temperature sensor on an EventSensor). There can be multiple points of the same point class on an EventSensor (e.g., 8 contact closures) and multiple sensor classes on an EventSensor (e.g., temperature, contact closure, humidity). If the point referenced by a given point index is solitary (e.g., temperature sensor, because there can be only one on an EventSensor), then this object reads as '<EventSensor name>'. Setting this object for solitary point indices sets the EventSensor name only. On the other hand, if a given point is among other points of the same point class on an EventSensor, then this object reads as '<Sensor name>'. Setting this object for these NON- solitary point indices sets the sensor name only - not the EventSensor name.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.1.1.1.4 |
esPointInEventStateA number referring to the event state of a point on an EventSensor. This number can have different meanings depending on the point class. If the point class is temperature, humidity, or analog input, then the values of this object are: 1=very low 2=low 3=normal 4=high 5=very high For contact closures the values of this object are: 1=point in event state 2=point in normal state For relays the values of this object are: 1=relay energized (active) 2=relay de-energized (inactive) For any point class and any point, if the event state is undefined, then the value of this object is 0. For any point class except relay, this object is read-only. For relays, setting this object to 1 puts the relay into its active (energized) state. Setting it to 2 puts the relay into its inactive (de-energized) state. Setting it to any value greater than 2 puts the relay into its active state for that many seconds (up to 3600), after which time it puts the relay into its inactive state.rw Integer32 .1.3.6.1.4.1.3052.17.1.1.1.1.5 |
esPointValueIntA read-only number referring to the value of a point on an EventSensor. If the point class is temperature, then this object is the temperature in its configured scale (default is Fahrenheit). If the point class is contact closure or relay, then this object is either 0 (open) or 1 (closed). If the point class is humidity, then this object is the percent relative humidity. If the point class is analog input, then this object is the signed input value in tenths of the configured units. If the point class is relay, then this object is either 1 (active a.k.a. energized) or 0 (inactive a.k.a. de-energized). This object cannot be used to control the relay (use esPointInEventState for that).rw Integer32 (-2147483648..2147483647) .1.3.6.1.4.1.3052.17.1.1.1.1.6 |
esPointValueStrA string referring to the value of a point on an EventSensor. For contact closures this object is either 'Open' or 'Closed'. For relays this object is either 'Active' (energized) or 'Inactive' (de-energized). For temperature and humidity point classes, this object is the string representation of the esPointValueInt object. For temperature, 'C' or 'F' is including in the string to indicate scale. For analog inputs, this object is the string representation of the plus/minus input in the configured units appended with the unit name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.1.1.1.7 |
esPointTimeLastChangeThe time of the last time an event was triggerred for a point on an EventSensor in MM/DD/YY HH:MM:SS format. For contact closures, the possible events are Active and Inactive. For temperature, humidity, and analog inputs, the possible events are Normal, High, Very High, Low, and Very Low. For relays, this object is a null string.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.1.1.1.8 |
esPointTimetickLastChangeThe time of the last time an event was triggerred for a point on an EventSensor in 100ths of seconds since reset. For contact closures, the possible events are Active and Inactive. For temperature, humidity, and analog inputs, the possible events are Normal, High, Very High, Low, and Very Low. For relays, this object is 0.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.3052.17.1.1.1.1.9 |
esPointAliasValueStrFor CC inputs, this is the CC active/inactive alias setting setting value that currently corresponds to the event state. So if the CC input is in the event state, then this object is the active alias setting value. If the CC input is in the normal state, then this object is the inactive alias setting value. For relay/power outputs, this is the output active/inactive alias setting value that currently corresponds to the output state. So if the output is in the active state, then this object is the active alias setting value. If the output is in hte inactive state, then this object is the inactive alias setting value. For non-CC and non-output sensors, this is the same as the esPointValueStr object.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.1.1.1.10 |
dataEventStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.1.2 |
deStatusTableData Event Status Table SEQUENCE OF DEStatus .1.3.6.1.4.1.3052.17.1.2.1 |
deStatusEntryEventSensor status entry DEStatus .1.3.6.1.4.1.3052.17.1.2.1.1 |
deStatusIndexIndex for Data Eventsro Integer32 .1.3.6.1.4.1.3052.17.1.2.1.1.1 |
deStatusNameData Event namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.2.1.1.2 |
deStatusCounterNumber of times a data record has matched this event's equation. Range: 1-999999999ro Integer32 .1.3.6.1.4.1.3052.17.1.2.1.1.3 |
deStatusThresholdNumber of times the equation is matched before an event is triggered. Range: 1-999999999ro Integer32 .1.3.6.1.4.1.3052.17.1.2.1.1.4 |
fuelSensorStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.1.6 |
fsStatusTableFuel sensor status table SEQUENCE OF FSStatus .1.3.6.1.4.1.3052.17.1.6.1 |
fsStatusEntryFuel sensor status table entry FSStatus .1.3.6.1.4.1.3052.17.1.6.1.1 |
fsStatusIndexIndex for fuel sensorsro Integer32 .1.3.6.1.4.1.3052.17.1.6.1.1.1 |
fsStatusNameFuel sensor namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.6.1.1.2 |
fsStatusDeviceStateFuel sensor device statero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.6.1.1.3 |
fsStatusVolumeValueStringFuel volume. Range is -2,147,483,648 to 2,147,483,647. This value reads -999 when the fuel sensor is disconnectedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.6.1.1.4 |
fsStatusVolumePercentLevelHeight of the fluid in the tank expressed as a percentage of the tank height, in hundredths of a percent.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.6.1.1.7 |
fsStatusVolumeInEventStateCurrent event status of the fuel sensor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.6.1.1.8 |
fsStatusCombinedCombined status string intended to be parsed by NMS: deviceState`deviceStateColorCode`percentRounded`valueAsFloat`volumeEventState`volumeEventStateColorCode`capacity`units`namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.6.1.1.9 |
wirelessModemStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.1.7 |
wmsStatusWireless modem statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.1 |
wmsSignalWireless modem Signal strengthro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.2 |
wmsRSSIWireless modem Signal strength (RSSI)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.3 |
wmsBERWireless modem Bit Error Ratero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.4 |
wmsUpdatedWireless modem info last update timero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.5 |
wmsRegistrationWireless modem registration statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.6 |
wmsLACWireless modem Location Area Codero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.7 |
wmsCellIDWireless modem Cell IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.8 |
wmsIMSIWireless modem Internation Mobile Subscriber Identity numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.9 |
wmsPhnumWireless modem phone numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.10 |
wmsLocalIPLocal IP address of modem on wireless networkro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.11 |
wmsMgfIDWireless modem manufacturer IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.12 |
wmsModelIDWireless modem model IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.13 |
wmsIMEIWireless modem International Mobile Equipment Identity numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.14 |
wmsRevIDWireless modem revision IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.15 |
wmsNetNameWireless modem network namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.16 |
wmsGPRSStatusWireless modem (E)GPRS statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.17 |
wmsBandWireless modem bandro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.18 |
wmsChannelWireless modem channelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.19 |
wmsCountryCodeWireless modem country codero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.20 |
wmsNetCodeWireless modem network codero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.21 |
wmsPLMNColorWireless modem PLMN colorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.22 |
wmsBScolorWireless modem BS colorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.23 |
wmsMpRACHWireless modem max power RACHro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.24 |
wmsMinRxLevelWireless modem minimum receive levelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.25 |
wmsBaseCoeffWireless modem base coefficientro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.26 |
wmsSIMStatusWWireless modem SIM statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.27 |
wmsICCIDWireless modem SIM ICCIDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.28 |
wmsModemTypeWireless modem typero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.7.29 |
acPowerMonitorStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.1.8 |
acpmStatusTableAC power monitor status table SEQUENCE OF ACPMStatus .1.3.6.1.4.1.3052.17.1.8.1 |
acpmStatusEntryAC power monitor status table entry ACPMStatus .1.3.6.1.4.1.3052.17.1.8.1.1 |
acpmsIndexIndex for AC power monitorsro Integer32 .1.3.6.1.4.1.3052.17.1.8.1.1.1 |
acpmsNameName for the AC power monitor device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.2 |
acpmsAvgVoltageValueStrAverage voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1). This could be either the average of the phase voltages, or the sum of the phase voltages, depending on device configuration.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.3 |
acpmsAvgVoltageMinStrMinimum average voltage value since last reset, in volts.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.4 |
acpmsAvgVoltageMaxStrMaximum average voltage value since last reset, in volts.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.5 |
acpmsAvgVoltageAvgStrAverage average voltage value since last reset, in volts. This is the unit's average of its measurements of the average voltage reported by the AC power monitor device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.6 |
acpmsAvgVoltageInEventStateEvent state of this AC power monitor voltage (Low, Normal, High, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.7 |
acpmsVoltagePhaseAValueStrPhase A voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.8 |
acpmsVoltagePhaseBValueStrPhase B voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.9 |
acpmsVoltagePhaseCValueStrPhase C voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.10 |
acpmsAvgCurrentValueStrAverage current, in amps. This is calculated using the formula (register * CT ratio * 0.001). This could be either the average of the phase currents, or the sum of the phase currents, depending on device configuration.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.11 |
acpmsAvgCurrentMinStrMinimum average current value since last reset, in amps.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.12 |
acpmsAvgCurrentMaxStrMaximum average current value since last reset, in amps.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.13 |
acpmsAvgCurrentAvgStrAverage average current value since last reset, in amps. This is the unit's average of its measurements of the average current reported by the AC power monitor device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.14 |
acpmsAvgCurrentInEventStateEvent state of this AC power monitor current (Low, Normal, High, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.15 |
acpmsCurrentPhaseAValueStrPhase A current, in amps. This is calculated using the formula (register * CT ratio * 0.001).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.16 |
acpmsCurrentPhaseBValueStrPhase B current, in amps. This is calculated using the formula (register * CT ratio * 0.001).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.17 |
acpmsCurrentPhaseCValueStrPhase C current, in amps. This is calculated using the formula (register * CT ratio * 0.001).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.18 |
acpmsAvgFreqValueStrFrequency, in hertz. On the YD2010, this is calculated using the formula (register * 0.00106813). On the WattsOn, this is calculated using the formula (register * 0.1).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.19 |
acpmsAvgFreqMinStrMinimum frequency value since last reset, in hertz.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.20 |
acpmsAvgFreqMaxStrMaximum frequency value since last reset, in hertz.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.21 |
acpmsAvgFreqAvgStrAverage frequency value since last reset, in hertz. This is the unit's average of its measurements of the average frequency reported by the AC power monitor device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.22 |
acpmsAvgFreqInEventStateEvent state of this AC power monitor frequency (Low, Normal, High, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.23 |
acpmsTRPValueStrTotal real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn models, this is calculated using the formula (register * PT * CT).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.24 |
acpmsTRPMinStrMinimum total real power value since last reset, in watts.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.25 |
acpmsTRPMaxStrMaximum total real power value since last reset, in watts.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.26 |
acpmsTRPAvgStrAverage total real power value since last reset, in watts. This is the unit's average of its measurements of the average total real power reported by the AC power monitor device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.27 |
acpmsTRPInEventStateEvent state of this AC power monitor total real power (Low, Normal, High, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.28 |
acpmsRPPhaseAValueStrPhase A real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.29 |
acpmsRPPhaseBValueStrPhase B real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.30 |
acpmsRPPhaseCValueStrPhase C real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.31 |
acpmsCombinedCombined status string intended to be parsed by NMS: name`deviceState`deviceStateColorCode`voltage`current`frequency`power~voltageEventState`voltageColorCode`currentEventState`currentColorCode`frequencyEventState`frequencyColorCode`powerEventState`powerColorCodero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.32 |
acpmsTPFValueStrTotal power factor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.33 |
acpmsTPFMinStrTotal power factor minimum value since last reset.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.34 |
acpmsTPFMaxStrTotal power factor maximum value since last reset.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.35 |
acpmsTPFAvgStrTotal power factor average value since last reset.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.36 |
acpmsTPFInEventStateTotal power factor event state.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.37 |
acpmsPFPhaseAValueStrPhase A power factor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.38 |
acpmsPFPhaseBValueStrPhase B power factor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.39 |
acpmsPFPhaseCValueStrPhase C power factor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.40 |
acpmsTRcPValueStrTotal reactive power, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.41 |
acpmsTRcPMinStrTotal reactive power minimum value since last reset, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.42 |
acpmsTRcPMaxStrTotal reactive power maximum value since last reset, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.43 |
acpmsTRcPAvgStrTotal reactive power average value since last reset, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.44 |
acpmsRcPPhaseAValueStrPhase A reactive power, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.45 |
acpmsRcPPhaseBValueStrPhase B reactive power, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.46 |
acpmsRcPPhaseCValueStrPhase C reactive power, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.47 |
acpmsTAPValueStrTotal apparent power, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.48 |
acpmsTAPMinStrTotal apparent power minimum value since last reset, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.49 |
acpmsTAPMaxStrTotal apparent power maximum value since last reset, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.50 |
acpmsTAPAvgStrTotal apparent power average value since last reset, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.51 |
acpmsAPPhaseAValueStrPhase A apparent power, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.52 |
acpmsAPPhaseBValueStrPhase B apparent power, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.53 |
acpmsAPPhaseCValueStrPhase C apparent power, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.8.1.1.54 |
acpmsTotalEnergyWhTotal energy, in Wh.ro Integer32 .1.3.6.1.4.1.3052.17.1.8.1.1.55 |
acpmsTotalEnergyVARTotal reactive energy, in VAR.ro Integer32 .1.3.6.1.4.1.3052.17.1.8.1.1.56 |
acpmsTotalEnergyVATotal apparent energy, in VA.ro Integer32 .1.3.6.1.4.1.3052.17.1.8.1.1.57 |
batteryMonitorStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.1.10 |
bmStatusTableBattery monitor status table. SEQUENCE OF BMStatus .1.3.6.1.4.1.3052.17.1.10.1 |
bmStatusEntryBattery monitor status table entry. BMStatus .1.3.6.1.4.1.3052.17.1.10.1.1 |
bmsIndexIndex for battery monitors.ro Integer32 .1.3.6.1.4.1.3052.17.1.10.1.1.1 |
bmsEnableON/OFF enable for this battery monitor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.2 |
bmsNameName for this battery monitor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.3 |
bmsStateThe connected state of the battery monitor. If you unplug the carrier then all three of its battery monitor states will reflect the same state change.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.4 |
bmsStringStateState of the string monitored by its battery monitor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.5 |
bmsTempValueAverage jar temperature value in C or F, depending on scale setting. Displayed as a floating point value. -999.0 means this is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.6 |
bmsTempValueStrAverage jar temperature with appropriate scale appended. Displayed as a floating point value. -999.0 means this is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.7 |
bmsTempEventEvent state of this battery monitor average jar temperature (Low, Normal, High).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.8 |
bmsDiffTempValueDifferential temperature in C or F, depending on scale setting. -999 means this is unknown.ro Integer32 .1.3.6.1.4.1.3052.17.1.10.1.1.9 |
bmsDiffTempValueStrDifferential temperature with appropriate scale (C or F) appended. -999 means this is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.10 |
bmsDiffTempEventEvent state of this battery monitor differential temperature (Very High, High, Normal).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.11 |
bmsVoltageValueTotal battery voltage on the string, in volts. Displayed as a floating point value in format X.X. -999.0 means this is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.12 |
bmsVoltageEventEvent state of this battery monitor string voltage (Low, Normal, High, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.13 |
bmsDiffVoltValueDifferential voltage in volts. Displayed as a floating point value in format X.X. -999.0 means this is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.14 |
bmsDiffVoltEventEvent state of this battery monitor differential voltage (Very High, High, Normal.)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.15 |
bmsCurrentValueCurrent flow on the string, in amperes. Displayed as a floating point value in format X.X. A positive value means the battery string is charging, and a negative value means the battery string is discharging. -999.0 means this is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.16 |
bmsChargingCurrentEventEvent state of this battery monitor charging current (Low, Normal, High, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.17 |
bmsDischargingCurrentEventEvent state of this battery monitor discharging current (Low, Normal, High, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.18 |
bmsChargeLevelValueCharge level of the battery string.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.19 |
bmsChargeLevelEventEvent state of this battery monitor charge level (Very Low, Low, Normal).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.20 |
bmsJarHealthValueJar health of the battery string.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.21 |
bmsJarHealthEventEvent state of this battery monitor jar health (Very Low, Low, Normal).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.22 |
bmsCombinedCombined status string intended to be parsed by NMS: name`deviceState`deviceStateColorCode`stringState`charge`voltage`temp`health~chargeEventState`chargeColorCode`voltageEventState`voltageColorCode`tempEventState`tempColorCode`healthEventState`healthColorCode`numActiveEventsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.1.1.23 |
bmsJarStatusTableThis table organizes per-jar attributes of a battery monitor: 1. voltage 2. temperature. SEQUENCE OF BMJarStatus .1.3.6.1.4.1.3052.17.1.10.2 |
bmJarStatusEntryEntry for battery monitor jar status table. Note this table uses 2 SNMP indexes: the first for which battery monitor and the second for which jar. BMJarStatus .1.3.6.1.4.1.3052.17.1.10.2.1 |
bmjsIndexBMThe part of the index that refers to which battery monitor.ro Integer32 .1.3.6.1.4.1.3052.17.1.10.2.1.1 |
bmjsIndexJarThe part of the index that refers to which jar.ro Integer32 .1.3.6.1.4.1.3052.17.1.10.2.1.2 |
bmjsVoltageValueVoltage of individual battery cell. This is a floating point value in format X.X. -999.0 means this is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.2.1.3 |
bmjsTempValueTemperature of individual battery jar. This is a floating point value. -999.0 means unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.1.10.2.1.4 |
bmjsAdmittanceValueCell admittance of individual jar. This is an integer value. -999 means unknown.ro Integer32 .1.3.6.1.4.1.3052.17.1.10.2.1.5 |
bmjsAdmittanceChangeValuePercent change of cell admittance of individual jar. This is an integer value.ro Integer32 .1.3.6.1.4.1.3052.17.1.10.2.1.6 |
config OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2 |
eventSensorBasics OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.1 |
esNumberEventSensorsThe number of EventSensors recognized by the unit, including the internal EventSensor. Range: 1-17ro Integer32 .1.3.6.1.4.1.3052.17.2.1.1 |
esTableThe table of what EventSensors are attached to the unit, including the internal EventSensor SEQUENCE OF ESExist .1.3.6.1.4.1.3052.17.2.1.2 |
esEntryTable entry for EventSensor table ESExist .1.3.6.1.4.1.3052.17.2.1.2.1 |
esIndexThis number refers to an EventSensor; it has the same meaning as the esIndexES object (see above), except that this object is used only within the esTable branch. This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndex=2 will now refer to that particular EventSensor.ro Integer32 .1.3.6.1.4.1.3052.17.2.1.2.1.1 |
esNameThe name of the EventSensorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.2 |
esIDThe factory-assigned ID of the EventSensorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.3 |
esNumberTempSensorsThe number of temperature sensors on the EventSensorro Integer32 .1.3.6.1.4.1.3052.17.2.1.2.1.4 |
esTempReportingModeDescription of how temperature values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.5 |
esNumberCCsThe number of contact closures on the EventSensor.ro Integer32 .1.3.6.1.4.1.3052.17.2.1.2.1.6 |
esCCReportingModeDescription of how CC values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.7 |
esNumberHumidSensorsThe number of humidity sensors on the EventSensor.ro Integer32 .1.3.6.1.4.1.3052.17.2.1.2.1.8 |
esHumidReportingModeDescription of how humidity sensor values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.9 |
esNumberNoiseSensorsThe number of noise sensors on the EventSensor.ro Integer32 .1.3.6.1.4.1.3052.17.2.1.2.1.10 |
esNoiseReportingModeDescription of how noise sensor values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.11 |
esNumberAirflowSensorsThe number of airflow sensors on the EventSensor.ro Integer32 .1.3.6.1.4.1.3052.17.2.1.2.1.12 |
esAirflowReportingModeDescription of how airflow sensor values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.13 |
esNumberAnalogThe number of analog inputs on the EventSensor.ro Integer32 .1.3.6.1.4.1.3052.17.2.1.2.1.14 |
esAnalogReportingModeDescription of how analog input values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.15 |
esNumberRelayOutputsThe number of relay outputs on the EventSensorro Integer32 .1.3.6.1.4.1.3052.17.2.1.2.1.16 |
esRelayReportingModeDescription of how relay output values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.17 |
esTempCombinedStatusCombined status string intended to be parsed by NMS: name`value`scale`eventState`eventColorCodero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.18 |
esCCCombinedStatusBlock1Combined status string intended to be parsed by NMS: numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventColorCode8`alias8ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.19 |
esCCCombinedStatusBlock2Combined status string intended to be parsed by NMS: numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`eventColorCode16`alias16ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.20 |
esCCCombinedStatusBlock3Combined status string intended to be parsed by NMS: numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value24`eventColorCode24`alias24ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.21 |
esCCCombinedStatusBlock4Combined status string intended to be parsed by NMS: numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value32`eventColorCode32`alias32ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.22 |
esCCCombinedStatusBlock5Combined status string intended to be parsed by NMS: numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value40`eventColorCode40`alias40ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.23 |
esCCCombinedStatusBlock6Combined status string intended to be parsed by NMS: numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value48`eventColorCode48`alias48ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.24 |
esCCCombinedStatusBlock7Combined status string intended to be parsed by NMS: numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value56`eventColorCode56`alias56ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.25 |
esCCCombinedStatusBlock8Combined status string intended to be parsed by NMS: numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`value64`eventColorCode64`alias64ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.26 |
esHumidCombinedStatusCombined status string intended to be parsed by NMS: name`value`eventState`eventColorCodero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.27 |
esAnalogCombinedStatusBlock1Combined status string intended to be parsed by NMS: numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.28 |
esAnalogCombinedStatusBlock2Combined status string intended to be parsed by NMS: numInBlock~name9`value9`units9`eventState9`eventColorCode9~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.29 |
esAnalogCombinedStatusBlock3Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.30 |
esAnalogCombinedStatusBlock4Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.31 |
esAnalogCombinedStatusBlock5Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.32 |
esAnalogCombinedStatusBlock6Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.33 |
esOutputCombinedStatusBlock1Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.34 |
esOutputCombinedStatusBlock2Combined status string intended to be parsed by NMS: numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliaszro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.2.1.35 |
esNewSensorsString representing the number of new (attached but unconfigured) EventSensorsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.1.3 |
eventSensorPointConfig OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.2 |
esPointConfigTempTableThis table organizes 3 basic attributes of temperature sensor points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number (always 1 for temp sensors) Points are referenced by a point config index. The point config index is a string of 2 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor within the context of this emperature point config table ; namely, which EventSensor, and which sensor (a.k.a. point) (always 1 for temperature sensors). SEQUENCE OF ESPointConfigTemp .1.3.6.1.4.1.3052.17.2.2.1 |
esPointConfigTempEntryEntry for EventSensor point config temperature table ESPointConfigTemp .1.3.6.1.4.1.3052.17.2.2.1.1 |
espcTempIndexESThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config temperature table; namely, which EventSensor, and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndexES=2 will now refer to that particular EventSensor.ro Integer32 .1.3.6.1.4.1.3052.17.2.2.1.1.1 |
espcTempIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcTempIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of temperature point configuration.ro Integer32 .1.3.6.1.4.1.3052.17.2.2.1.1.2 |
espcTempEnableON/OFF enable this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.3 |
espcTempScaleScale (C/F) for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.4 |
espcTempDeadbandDeadband for this temperature sensor (in floating-point format)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.5 |
espcTempVHighTempVery high temperature event threshold for this temperature sensor (in floating-point format)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.6 |
espcTempVHighActionsVery high temperature event actions for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.7 |
espcTempVHighTrapnumVery high temperature event trap number for this temperature sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.1.1.8 |
espcTempVHighClassVery high temperature event class for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.9 |
espcTempHighTempHigh temperature event threshold for this temperature sensor (in floating-point format)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.10 |
espcTempHighActionsHigh temperature event actions for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.11 |
espcTempHighTrapnumHigh temperature event trap number for this temperature sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.1.1.12 |
espcTempHighClassHigh temperature event class for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.13 |
espcTempNormalActionsReturn-to-normal event actions for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.14 |
espcTempNormalTrapnumReturn-to-normal event trap number for this temperature sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.1.1.15 |
espcTempNormalClassReturn-to-normal event class for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.16 |
espcTempLowTempLow temperature event threshold for this temperature sensor (in floating-point format)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.17 |
espcTempLowActionsLow temperature event actions for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.18 |
espcTempLowTrapnumLow temperature event trap number for this temperature sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.1.1.19 |
espcTempLowClassLow temperature event class for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.20 |
espcTempVLowTempVery Low temperature event threshold for this temperature sensor (in floating-point format)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.21 |
espcTempVLowActionsVery Low temperature event actions for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.22 |
espcTempVLowTrapnumVery Low temperature event trap number for this temperature sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.1.1.23 |
espcTempVLowClassVery Low temperature event class for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.1.1.24 |
esPointConfigCCTableThis table organizes 3 basic attributes of contact closure points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this contact closure point config table ; namely, which EventSensor and which sensor. SEQUENCE OF ESPointConfigCC .1.3.6.1.4.1.3052.17.2.2.2 |
esPointConfigCCEntryEntry for EventSensor point config contact closure table ESPointConfigCC .1.3.6.1.4.1.3052.17.2.2.2.1 |
espcCCIndexESThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.ro Integer32 .1.3.6.1.4.1.3052.17.2.2.2.1.1 |
espcCCIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcCCIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration.ro Integer32 .1.3.6.1.4.1.3052.17.2.2.2.1.2 |
espcCCEnableON/OFF enable for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.2.1.3 |
espcCCNameName for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.2.1.4 |
espcCCEventStateEvent state for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.2.1.5 |
espcCCThresholdEvent threshold (seconds) for this contact closurerw Integer32 .1.3.6.1.4.1.3052.17.2.2.2.1.6 |
espcCCEventActionsEvent actions for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.2.1.7 |
espcCCEventTrapnumEvent trap number for this contact closurerw Integer32 .1.3.6.1.4.1.3052.17.2.2.2.1.8 |
espcCCEventClassEvent class for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.2.1.9 |
espcCCNormalActionsReturn-to-normal actions for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.2.1.10 |
espcCCNormalTrapnumReturn-to-normal trap number for this contact closurerw Integer32 .1.3.6.1.4.1.3052.17.2.2.2.1.11 |
espcCCNormalClassReturn-to-normal class for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.2.1.12 |
espcCCAlarmAliasEvent alias for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.2.1.13 |
espcCCNormalAliasReturn-to-normal alias for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.2.1.14 |
espcCCNormalThresholdEvent threshold (seconds) for this contact closure to return to normalrw Integer32 .1.3.6.1.4.1.3052.17.2.2.2.1.15 |
esPointConfigHumidTableThis table organizes 3 basic attributes of humidity points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number (always 1 for humidity sensors) Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this humidity point config table ; namely, which EventSensor and which sensor. SEQUENCE OF ESPointConfigHumid .1.3.6.1.4.1.3052.17.2.2.3 |
esPointConfigHumidEntryEntry for EventSensor point config humidity table ESPointConfigHumid .1.3.6.1.4.1.3052.17.2.2.3.1 |
espcHumidIndexESThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.ro Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.1 |
espcHumidIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcHumidIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration.ro Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.2 |
espcHumidEnableON/OFF enable for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.3.1.3 |
espcHumidDeadbandDeadband for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.4 |
espcHumidVHighHumidVery high event threshold for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.5 |
espcHumidVHighActionsVery high event actions for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.3.1.6 |
espcHumidVHighTrapnumVery high event trap number for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.7 |
espcHumidVHighClassVery high event class for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.3.1.8 |
espcHumidHighHumidHigh event threshold for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.9 |
espcHumidHighActionsHigh event actions for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.3.1.10 |
espcHumidHighTrapnumHigh event trap number for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.11 |
espcHumidHighClassHigh event class for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.3.1.12 |
espcHumidNormalActionsReturn-to-normal actions for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.3.1.13 |
espcHumidNormalTrapnumReturn-to-normal trap number for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.14 |
espcHumidNormalClassReturn-to-normal class for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.3.1.15 |
espcHumidLowHumidLow event threshold for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.16 |
espcHumidLowActionsLow event actions for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.3.1.17 |
espcHumidLowTrapnumLow event trap number for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.18 |
espcHumidLowClassLow event class for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.3.1.19 |
espcHumidVLowHumidVery low event threshold for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.20 |
espcHumidVLowActionsVery low event actions for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.3.1.21 |
espcHumidVLowTrapnumVery low event trap number for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.3.1.22 |
espcHumidVLowClassVery low event class for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.3.1.23 |
esPointConfigAITableThis table organizes 3 basic attributes of analog input points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this analog input point config table ; namely, which EventSensor and which sensor. SEQUENCE OF ESPointConfigAnalogInput .1.3.6.1.4.1.3052.17.2.2.5 |
esPointConfigAIEntryEntry for EventSensor point config analog input table ESPointConfigAnalogInput .1.3.6.1.4.1.3052.17.2.2.5.1 |
espcAIIndexESThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.ro Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.1 |
espcAIIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcAIIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration.ro Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.2 |
espcAIEnableON/OFF for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.3 |
espcAIPolarityPolarity for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.4 |
espcAIDeadbandDeadband for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.5 |
espcAIVhighValueVery high event threshold (decivolts or tenths of milliamps) for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.6 |
espcAIVhighActionsVery high event actions for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.7 |
espcAIVhighTrapnumVery high event trap number for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.8 |
espcAIVhighClassVery high event class for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.9 |
espcAIHighValueHigh event threshold (decivolts or tenths of milliamps) for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.10 |
espcAIHighActionsHigh event actions for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.11 |
espcAIHighTrapnumHigh event trap number for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.12 |
espcAIHighClassHigh event class for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.13 |
espcAINormalActionsReturn-to-normal actions for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.14 |
espcAINormalTrapnumReturn-to-normal trap number for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.15 |
espcAINormalClassReturn-to-normal class for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.16 |
espcAILowValueLow event threshold (decivolts or tenths of milliamps) for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.17 |
espcAILowActionsLow event actions for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.18 |
espcAILowTrapnumLow event trap number for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.19 |
espcAILowClassLow event class for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.20 |
espcAIVlowValueVery low event threshold (decivolts or tenths of milliamps) for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.21 |
espcAIVlowActionsVery low event actions for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.22 |
espcAIVlowTrapnumVery low event actions for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.23 |
espcAIVlowClassVery low event class for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.24 |
espcAIConvUnitNameConverstion unit name for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.25 |
espcAIConvHighValueConversion high value for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.26 |
espcAIConvHighUnitConversion high unit value for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.27 |
espcAIConvHighSignConversion high sign for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.28 |
espcAIConvLowValueConversion low value for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.29 |
espcAIConvLowUnitConversion unit low unit value for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.17.2.2.5.1.30 |
espcAIConvLowSignConversion low sign for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.2.5.1.31 |
serialPorts OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.3 |
numberPortsNumber of RS-232 ports found. Range: 2 or 4ro Integer32 .1.3.6.1.4.1.3052.17.2.3.1 |
portConfigTablePort config table SEQUENCE OF PortConfig .1.3.6.1.4.1.3052.17.2.3.2 |
portConfigEntryPort config entry PortConfig .1.3.6.1.4.1.3052.17.2.3.2.1 |
portConfigIndexIndex for portsro Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.1 |
portConfigBaudBaud rate, 19200, 9600, etc.rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.2 |
portConfigDataFormatValue representing word length, parity, and stop bits: 0=8N1, 1=7E1, 2=7O1, 3=7N1, 4=8O2rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.3 |
portConfigStripPtOutputLfsStrip passthrough LFs sent to device on this port: 1=yes, 0=no.rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.4 |
portConfigStripPtInputLfsStrip passthrough LFs received from device on this port: 1=yes, 0=no.rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.5 |
portConfigMaskEnable1=Use the character mask on this port. 0=Do not use the mask. When the mask is enabled, the following ASCII characters are ignored on the port: 0, 1, 4-9, 11, 12, 14-31, 128-255. When the mask is disabled, all characters are accepted on the port.rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.7 |
portConfigDAEnable1=Enable the Data Alarm Evaluator for data on this port. 0=Do not evaluate data on this port.rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.8 |
portConfigStoreAlarmsDPTON/OFF: store alarms received during passthroughrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.9 |
portConfigRecordTimeoutTimeout after last unterminated data received upon which data collected so far is stored as a record.rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.10 |
portConfigDataTypeHow the port interprets incoming data: ASCII/BINARYrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.11 |
portConfigEtxToCRLFON/OFF whether the port translates incoming ETX to CRLFrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.12 |
portConfigMLREnableON/OFF Whether Multiline Records are collected on this port.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.13 |
portConfigMLRStartField1PosPosition of MLR start field 1rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.14 |
portConfigMLRStartField1TextText to match MLR start field 1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.15 |
portConfigMLRStartField2PosPosition of MLR start field 2rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.16 |
portConfigMLRStartField2TextText to match MLR start field 2rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.17 |
portConfigMLRNumLinesBeforeNumber of lines before the starting line which should be included in the MLRrw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.18 |
portConfigMLREndDetectionHow the MLR parser determines what ends an MLR: by FORMULA, number of lines received so far (COUNT), or number of blank lines received so far (BLANKS)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.19 |
portConfigMLRLineCountNumber of lines in the MLR (used by the end detection mode)rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.20 |
portConfigMLREndField1PosPosition of MLR end field 1rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.21 |
portConfigMLREndField1TextText to match MLR end field 1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.22 |
portConfigMLREndField2PosPosition of MLR end field 2rw Integer32 .1.3.6.1.4.1.3052.17.2.3.2.1.23 |
portConfigMLREndField2TextText to match MLR end field 2rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.24 |
portConfigMLRUseComplexRulesON/OFF MLR parser uses complex rules (field possitions/ formulas, etc.)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.25 |
portConfigBufferPTON/OFF records received during passthrough mode are buffered/stored in the databaserw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.26 |
portConfigIdThe text identifer for the portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.3.2.1.27 |
network OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4 |
interface OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1 |
ethernet OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1 |
ethernet1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.1 |
eth1ModeMode of the Ethernet1 interface: STATIC,DHCP,VLANro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.1.1.1.1 |
eth1AddressEthernet1 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.2 |
eth1SubnetMaskEthernet1 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.3 |
eth1RouterEthernet1 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.4 |
eth1VLAN OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.1.5 |
eth1VLAN1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.1 |
eth1VLAN1IDEthernet1 VLAN1 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.1.1 |
eth1VLAN1PriorityEthernet1 VLAN1 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.1.2 |
eth1VLAN1AddressEthernet1 VLAN1 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.1.3 |
eth1VLAN1SubnetMaskEthernet1 VLAN1 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.1.4 |
eth1VLAN1RouterEthernet1 VLAN1 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.1.5 |
eth1VLAN2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.2 |
eth1VLAN2IDEthernet1 VLAN2 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.2.1 |
eth1VLAN2PriorityEthernet1 VLAN2 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.2.2 |
eth1VLAN2AddressEthernet1 VLAN2 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.2.3 |
eth1VLAN2SubnetMaskEthernet1 VLAN2 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.2.4 |
eth1VLAN2RouterEthernet1 VLAN2 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.2.5 |
eth1VLAN3 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.3 |
eth1VLAN3IDEthernet1 VLAN3 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.3.1 |
eth1VLAN3PriorityEthernet1 VLAN3 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.3.2 |
eth1VLAN3AddressEthernet1 VLAN3 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.3.3 |
eth1VLAN3SubnetMaskEthernet1 VLAN3 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.3.4 |
eth1VLAN3RouterEthernet1 VLAN3 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.3.5 |
eth1VLAN4 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.4 |
eth1VLAN4IDEthernet1 VLAN4 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.4.1 |
eth1VLAN4PriorityEthernet1 VLAN4 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.4.2 |
eth1VLAN4AddressEthernet1 VLAN4 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.4.3 |
eth1VLAN4SubnetMaskEthernet1 VLAN4 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.4.4 |
eth1VLAN4RouterEthernet1 VLAN4 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.4.5 |
eth1VLAN5 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.5 |
eth1VLAN5IDEthernet1 VLAN5 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.5.1 |
eth1VLAN5PriorityEthernet1 VLAN5 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.5.2 |
eth1VLAN5AddressEthernet1 VLAN5 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.5.3 |
eth1VLAN5SubnetMaskEthernet1 VLAN5 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.5.4 |
eth1VLAN5RouterEthernet1 VLAN5 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.5.5 |
eth1VLAN6 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.6 |
eth1VLAN6IDEthernet1 VLAN6 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.6.1 |
eth1VLAN6PriorityEthernet1 VLAN6 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.6.2 |
eth1VLAN6AddressEthernet1 VLAN6 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.6.3 |
eth1VLAN6SubnetMaskEthernet1 VLAN6 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.6.4 |
eth1VLAN6RouterEthernet1 VLAN6 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.1.5.6.5 |
eth1MACEthernet1 MACro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.1.1.1.6 |
ethernet2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.2 |
eth2ModeMode of the Ethernet2 interface: STATIC,DHCP,VLANro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.1.1.2.1 |
eth2AddressEthernet2 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.2 |
eth2SubnetMaskEthernet2 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.3 |
eth2RouterEthernet2 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.4 |
eth2VLAN OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.2.5 |
eth2VLAN1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.1 |
eth2VLAN1IDEthernet2 VLAN1 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.1.1 |
eth2VLAN1PriorityEthernet2 VLAN1 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.1.2 |
eth2VLAN1AddressEthernet2 VLAN1 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.1.3 |
eth2VLAN1SubnetMaskEthernet2 VLAN1 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.1.4 |
eth2VLAN1RouterEthernet2 VLAN1 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.1.5 |
eth2VLAN2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.2 |
eth2VLAN2IDEthernet2 VLAN2 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.2.1 |
eth2VLAN2PriorityEthernet2 VLAN2 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.2.2 |
eth2VLAN2AddressEthernet2 VLAN2 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.2.3 |
eth2VLAN2SubnetMaskEthernet2 VLAN2 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.2.4 |
eth2VLAN2RouterEthernet2 VLAN2 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.2.5 |
eth2VLAN3 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.3 |
eth2VLAN3IDEthernet2 VLAN3 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.3.1 |
eth2VLAN3PriorityEthernet2 VLAN3 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.3.2 |
eth2VLAN3AddressEthernet2 VLAN3 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.3.3 |
eth2VLAN3SubnetMaskEthernet2 VLAN3 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.3.4 |
eth2VLAN3RouterEthernet2 VLAN3 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.3.5 |
eth2VLAN4 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.4 |
eth2VLAN4IDEthernet2 VLAN4 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.4.1 |
eth2VLAN4PriorityEthernet2 VLAN4 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.4.2 |
eth2VLAN4AddressEthernet2 VLAN4 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.4.3 |
eth2VLAN4SubnetMaskEthernet2 VLAN4 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.4.4 |
eth2VLAN4RouterEthernet2 VLAN4 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.4.5 |
eth2VLAN5 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.5 |
eth2VLAN5IDEthernet2 VLAN5 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.5.1 |
eth2VLAN5PriorityEthernet2 VLAN5 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.5.2 |
eth2VLAN5AddressEthernet2 VLAN5 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.5.3 |
eth2VLAN5SubnetMaskEthernet2 VLAN5 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.5.4 |
eth2VLAN5RouterEthernet2 VLAN5 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.5.5 |
eth2VLAN6 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.6 |
eth2VLAN6IDEthernet2 VLAN6 IDrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.6.1 |
eth2VLAN6PriorityEthernet2 VLAN6 priorityrw Integer32 .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.6.2 |
eth2VLAN6AddressEthernet2 VLAN6 IP addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.6.3 |
eth2VLAN6SubnetMaskEthernet2 VLAN6 subnet maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.6.4 |
eth2VLAN6RouterEthernet2 VLAN6 routerrw IpAddress .1.3.6.1.4.1.3052.17.2.4.1.1.2.5.6.5 |
eth2MACEthernet2 MACro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.1.1.2.6 |
defaultRouterThe default router/gatewayrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.2 |
dnsTableDNS server address table SEQUENCE OF DNSConfig .1.3.6.1.4.1.3052.17.2.4.3 |
dnsEntryDNS server address entry DNSConfig .1.3.6.1.4.1.3052.17.2.4.3.1 |
dnsIndexIndex for DNS server addressro Integer32 .1.3.6.1.4.1.3052.17.2.4.3.1.1 |
dnsAddressDNS server addressrw IpAddress .1.3.6.1.4.1.3052.17.2.4.3.1.2 |
hostnameThe hostname of the unitrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.4 |
hostTableStatic host table SEQUENCE OF HostConfig .1.3.6.1.4.1.3052.17.2.4.5 |
hostEntryStatic host entry HostConfig .1.3.6.1.4.1.3052.17.2.4.5.1 |
hostIndexIndex for static hostro Integer32 .1.3.6.1.4.1.3052.17.2.4.5.1.1 |
hostDeclarationStatic host declaration string (i.e. 'address hostname')rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.5.1.2 |
ncpDuplexFor network command processor: 1=Input characters are echoed; 0=no echo.rw Integer32 .1.3.6.1.4.1.3052.17.2.4.6 |
ncpTimeoutNetwork command processor inactivity timeoutrw Integer32 .1.3.6.1.4.1.3052.17.2.4.7 |
snmp OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.8 |
snmpAgentEnableON/OFF for snmp agentrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.1 |
snmpNotificationTx OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.8.7 |
snmpNtfnAttemptsMaximum of times the unit attempts to send a notification (trap/inform) in 1 cyclerw Integer32 .1.3.6.1.4.1.3052.17.2.4.8.7.1 |
snmpNtfnTimeoutNumber of seconds between retries of sending a notificationrw Integer32 .1.3.6.1.4.1.3052.17.2.4.8.7.2 |
snmpNtfnCyclesNumber of times the unit attempts a group of attempts to send a notification (a cycle)rw Integer32 .1.3.6.1.4.1.3052.17.2.4.8.7.3 |
snmpNtfnSnoozeMinutes between cyclesrw Integer32 .1.3.6.1.4.1.3052.17.2.4.8.7.4 |
snmpProxy OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.8.8 |
snmpProxyTableTable of SNMP proxy entries SEQUENCE OF SNMPProxyTable .1.3.6.1.4.1.3052.17.2.4.8.8.1 |
snmpProxyEntryEntry for SNMP proxy table SNMPProxyTable .1.3.6.1.4.1.3052.17.2.4.8.8.1.1 |
snmpProxyIndexIndex for SNMP proxy tablero Integer32 .1.3.6.1.4.1.3052.17.2.4.8.8.1.1.1 |
snmpProxyOIDBranchThe OID branch to trigger the proxy function. This should cover the device to proxy.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.8.1.1.2 |
snmpProxyIPThe IP address of the device to proxy.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.8.1.1.3 |
snmpProxyPortThe UDP port on which the device to proxy listens.rw Integer32 .1.3.6.1.4.1.3052.17.2.4.8.8.1.1.4 |
snmpPoll OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.8.9 |
snmpPModeMode of poll operation: OFF or POLL ONLY (just make the results available to view).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.9.1 |
snmpPRequestTableTable of SNMP Poll requests. SEQUENCE OF SNMPPollRequestConfig .1.3.6.1.4.1.3052.17.2.4.8.9.4 |
snmpPRequestEntryEntry for table pf SNMP Poll requests. SNMPPollRequestConfig .1.3.6.1.4.1.3052.17.2.4.8.9.4.1 |
snmpPRequestIndexIndex for table of SNMP Poll requests.ro Integer32 .1.3.6.1.4.1.3052.17.2.4.8.9.4.1.1 |
snmpPRequestDescriptionA description for this single telemetry request; no functional effect.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.9.4.1.2 |
snmpPRequestAgentSNMP Agent IP address or hostname for this single telemetry request.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.9.4.1.3 |
snmpPRequestReadcomSNMP read community for this single telemetry request.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.9.4.1.4 |
snmpPRequestOIDSNMP object identifier for this single telemetry request.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.9.4.1.5 |
snmpPRequestPeriodHow many seconds between periodic SNMP polls of this single telemetry request.rw Integer32 .1.3.6.1.4.1.3052.17.2.4.8.9.4.1.6 |
snmpPRequestResultStatusStatus of the last attempt for this telemetry request.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.9.4.1.10 |
snmpPRequestResultValueThe telemetry value if the last request was successful.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.9.4.1.11 |
snmpPRequestResultTimeThe timestamp of the last telemetry request.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.9.4.1.12 |
snmpPRequestResultTypeThe type of the telemetry as reported by the agent.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.8.9.4.1.13 |
ftpPush OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.9 |
ftpPushEnableEnable FTP push for REGULAR (protocol: FTP) or SECURE (protocol: SFTP) operation, or disable it (OFF)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.1 |
ftpPushServerFTP server to which data should be pushedrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.2 |
ftpPushAccountFTP push accountrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.5 |
ftpPushDirectoryFTP push directoryrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.6 |
ftpPushperiodMinutes between pushesrw Integer32 .1.3.6.1.4.1.3052.17.2.4.9.7 |
ftpPushPushFileTableTable of files to push SEQUENCE OF FTPPushPushFileConfig .1.3.6.1.4.1.3052.17.2.4.9.8 |
ftpPushPushFileEntryEntry for table of files to push FTPPushPushFileConfig .1.3.6.1.4.1.3052.17.2.4.9.8.1 |
ftpPushPushFileIndexIndex for table of files to pushro Integer32 .1.3.6.1.4.1.3052.17.2.4.9.8.1.1 |
ftpPushPushFileON/OFF push this local FILExrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.8.1.2 |
ftpPushPushAuditON/OFF push the audit logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.9 |
ftpPushPushAlarmsON/OFF push the alarms/events filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.10 |
ftpPushRemoteFileTableTable of remote names of files to push SEQUENCE OF FTPPushRemoteFileConfig .1.3.6.1.4.1.3052.17.2.4.9.11 |
ftpPushRemoteFileEntryEntry for table of remote names of files to push FTPPushRemoteFileConfig .1.3.6.1.4.1.3052.17.2.4.9.11.1 |
ftpPushRemoteFileIndexIndex for table of remote names of files to pushro Integer32 .1.3.6.1.4.1.3052.17.2.4.9.11.1.1 |
ftpPushRemoteFileNameremote name of pushed FILEx (name on server)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.11.1.2 |
ftpPushRemoteAlarmNameFilename on server for alarmsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.12 |
ftpPushPassiveON/OFF use ftp passive moderw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.13 |
ftpPushIncludeDateON/OFF include the date in the name of the pushed filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.14 |
ftpPushIncludeTimeON/OFF include the time in the name of the pushed filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.15 |
ftpPushIncludeSeqON/OFF include a sequence number in the name of the pushed filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.9.16 |
routing OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.11 |
ethRoutingEnableON/OFF unit routes IP traffic from Ethernet to PPP/Wirelessrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.11.2 |
ethRoutingNATEnableON/OFF unit applies NAT on routed IP frames egressing the unit on its PPP interfacerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.11.3 |
netSecurity OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.12 |
ipRestriction OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.12.1 |
ipRestrictionTableTable of IP restrictions SEQUENCE OF IPRestrictionConfig .1.3.6.1.4.1.3052.17.2.4.12.1.1 |
ipRestrictionEntryEntry for table of IP restrictions IPRestrictionConfig .1.3.6.1.4.1.3052.17.2.4.12.1.1.1 |
ipRestrictionIndexIndex for table of IP restrictionsro Integer32 .1.3.6.1.4.1.3052.17.2.4.12.1.1.1.1 |
ipRestrictionEnableON/OFF enable this IP restrictionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.12.1.1.1.2 |
ipRestrictionMaskIP restriction maskrw IpAddress .1.3.6.1.4.1.3052.17.2.4.12.1.1.1.3 |
rts OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.13 |
rtsFileTableTable of RTS files SEQUENCE OF RTSFileConfig .1.3.6.1.4.1.3052.17.2.4.13.1 |
rtsFileEntryEntry for table of RTS files RTSFileConfig .1.3.6.1.4.1.3052.17.2.4.13.1.1 |
rtsFileIndexIndex for table of RTS filesro Integer32 .1.3.6.1.4.1.3052.17.2.4.13.1.1.1 |
rtsFileModeRTS mode (OFF,LISTEN,PUSH) for FILExrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.13.1.1.2 |
rtsFileShowAnswerShow answer string upon RTS connect for FILExrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.13.1.1.3 |
rtsFileReqXONON/OFF require XON to start flow for FILExrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.13.1.1.4 |
rtsFileTimeoutIdle connection close timer (0 means no timeout) for FILExrw Integer32 .1.3.6.1.4.1.3052.17.2.4.13.1.1.5 |
rtsFileEmptyCloseON/OFF close the socket when FILEx is emptyrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.13.1.1.6 |
rtsFilePushHostHost to which FILEx should be pushed via RTSrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.13.1.1.7 |
rtsFilePushPortTCP port to which FILEx should be pushed via RTSrw Integer32 .1.3.6.1.4.1.3052.17.2.4.13.1.1.8 |
rtsFilePushRetryTimerRetry timer (seconds) for retrying failed RTS push connect attemptsrw Integer32 .1.3.6.1.4.1.3052.17.2.4.13.1.1.9 |
rtsAlarms OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.13.2 |
rtsAlarmsModeRTS mode (OFF,LISTEN,PUSH) for alarms filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.13.2.1 |
rtsAlarmsShowAnswerShow answer string upon RTS connect for alarms filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.13.2.2 |
rtsAlarmsReqXONON/OFF require XON to start flow for alarms filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.13.2.3 |
rtsAlarmsTimeoutIdle connection close timer (0 means no timeout) for alarms filerw Integer32 .1.3.6.1.4.1.3052.17.2.4.13.2.4 |
rtsAlarmsEmptyCloseON/OFF close the socket when this file is empty for alarms filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.13.2.5 |
rtsAlarmsPushHostHost to which alarms file should be pushed via RTSrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.13.2.6 |
rtsAlarmsPushPortTCP port to which alarms file should be pushed via RTSrw Integer32 .1.3.6.1.4.1.3052.17.2.4.13.2.7 |
rtsAlarmsPushRetryTimerRetry timer (seconds) for retrying failed RTS push connect attemptsrw Integer32 .1.3.6.1.4.1.3052.17.2.4.13.2.8 |
trap OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.14 |
trapInclude OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.14.1 |
trapIncludeDateTimeON/OFF include date and time in stock trap messagerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.14.1.1 |
trapIncludeSiteNameON/OFF include site name in stock trap messagerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.14.1.2 |
trapIncludeSensorIDON/OFF include sensor ID in stock trap messagerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.14.1.3 |
trapIncludeUDNameON/OFF include user defined name in stock trap messagerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.14.1.4 |
trapIncludeUDStateON/OFF include user defined state in stock trap messagerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.14.1.5 |
trapIncludeSourceAddressON/OFF include source IP address in stock trap messagerw IpAddress .1.3.6.1.4.1.3052.17.2.4.14.1.6 |
trapAuthFailEnableON/OFF enable trap sent upon SNMP authentication failurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.14.2 |
wireless OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.16 |
wirelessModeWireless mode (OFF,PERMANENT-EDGE)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.16.1 |
wirelessAPNWireless access point namerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.16.2 |
wirelessIdleTimeoutWireless idle timeoutrw Integer32 .1.3.6.1.4.1.3052.17.2.4.16.3 |
wirelessPINWireless modem SIM PINrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.16.5 |
wirelessDREDefault route enable for wireless network interface. When this is ON, the wireless link, if up, becomes the default route, overriding the default route setting (defaultRouter object). When OFF, the default route setting controls the default route and the wireless link does not become the default route.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.16.9 |
email OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.17 |
emailServerSMTP server to which the unit sends emailrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.17.1 |
emailDomainDomain to use in recipient addressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.17.2 |
emailAuthEnableON/OFF enable SMTP authenticationrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.17.3 |
netAdvanced OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.18 |
arpFilterARP filter coderw Integer32 .1.3.6.1.4.1.3052.17.2.4.18.1 |
web OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.4.19 |
webEnableON/OFF for the web interfacerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.4.19.1 |
webPortTCP port on which web interface listensrw Integer32 .1.3.6.1.4.1.3052.17.2.4.19.2 |
webTimeoutWeb interface session timeout (seconds)rw Integer32 .1.3.6.1.4.1.3052.17.2.4.19.3 |
time OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.8 |
clockText string for date and time; e.g. 'SUN 01/02/98 12:34:27'. When setting this object, only the date and time are required; the unit will ignore a specified day of week because it is calculated from the date and time. When this object is included in a notification as a varbind, it represents the time that the triggering event occurred.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.8.1 |
console OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.10 |
consoleDuplexON/OFF characters echoed on telnet command sessionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.10.1 |
consoleTimeoutMinutes of inactivity after which telnet command session is terminatedrw Integer32 .1.3.6.1.4.1.3052.17.2.10.2 |
consoleConfirmON/OFF Prompt to confirm certain actionsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.10.7 |
unitSecurity OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.11 |
secCore OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.11.1 |
scShowPasswordPromptON/OFF show password prompt upon loginrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.1.1 |
scConsoleLoginRequiredON/OFF login required upon connecting via consolerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.1.2 |
scModemLoginRequiredON/OFF login required upon connecting via modemrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.1.3 |
scTelnetLoginRequiredON/OFF login required upon connecting via Telnetrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.1.4 |
scTelnetPTLoginRequiredON/OFF login required upon connecting via Telnet to pass- through ports (TCP ports 210x)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.1.5 |
scRTSLoginRequiredON/OFF login required upon connecting to RTS (TCP ports 220x)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.1.6 |
scAuthModeAuthentication mode (USERNAME/PW,PW/USERNAME,PASSWORD ONLY)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.1.7 |
scRightsGroupThe set of aliases used for the 8 available rights levelsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.1.8 |
scSecretShared secret for challengesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.1.9 |
secUserTableTable of users SEQUENCE OF SecUserConfig .1.3.6.1.4.1.3052.17.2.11.2 |
secUserEntryEntry for table of users SecUserConfig .1.3.6.1.4.1.3052.17.2.11.2.1 |
secUserIndexIndex for table of usersro Integer32 .1.3.6.1.4.1.3052.17.2.11.2.1.1 |
secUserEnableON/OFF enable userrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.2 |
secUserConnectViaMethods by which user is allowed to connect: L=local (console) T=Telnet F=FTP R=RTS Ss=SSH W=Webrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.5 |
secUserLoginToThe function presented to the user upon login (COMMAND, PASSTHROUGH,MENU)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.6 |
secUserAccessFileThe default access file associated with the userrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.7 |
secUserPTEscapeToThe function presented to the user upon escaping pass- through: currently only MENUrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.9 |
secUserPPPTypeThe kind of PPP access allowed to this user cannot connect via PPP (NONE), can connect but only to the unit (LOCAL), or can connect and route to Ethernet (ROUTING)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.10 |
secUserRightsThe rights level granted to this userrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.11 |
secUserEventsReadAccessDENY/ALLOW user to read the events/alarms filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.13 |
secUserAuditReadAccessDENY/ALLOW user to read the audit logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.14 |
secUserEventsWriteAccessDENY/ALLOW user to delete the events filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.16 |
secUserAuditWriteAccessDENY/ALLOW user to write to the audit logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.17 |
secUserExpirationExpiration date/time of this userrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.18 |
secUserCallbackNumber1Number slot 1 the unit calls for dialbackrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.19 |
secUserCallbackNumber2Number slot 2 the unit calls for dialbackrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.20 |
secUserCallbackNumber3Number slot 3 the unit calls for dialbackrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.21 |
secUserChallengeTelnetModeTelnet challenge mode: when user logs in via telnet, unit allows access (OFF), presents a challenge (CHALLENGE), or unit sends a one-time-password (SEND PASSWORD) to a destination configured by secUserChallengeTelnetSendTorw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.22 |
secUserChallengeModemModeModem challenge mode: when user logs in via modem, unit allows access (OFF), presents a challenge (CHALLENGE), sends a one-time-password (SEND PASSWORD) to a destination configured by secUserChallengeTelnetSendTo, or dials a number (CALLBACK) configured with secUserCallbackNumberxrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.23 |
secUserChallengeConsoleModeConsole challenge mode: when user logs in via console, unit allows access (OFF), or presents a challenge (CHALLENGE)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.24 |
secUserChallengeTelnetSendToEmail action used as the destination address for one-time- password when a user logs in with a challenge mode of SEND PASSWORDrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.25 |
secUserChallengeModemSendToModem action used as the destination phone number for one- time-password when a user logs in with a challenge mode of SEND PASSWORDrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.2.1.26 |
secUserChallengeExpirationTime (in minutes) after which a one-time-password is sent that it can be used to log inrw Integer32 .1.3.6.1.4.1.3052.17.2.11.2.1.27 |
secFactory OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.11.3 |
sfEnableON/OFF enable factory accessrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.3.1 |
sfSecretSecret used for factory accessrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.11.3.2 |
event OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12 |
evCore OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12.1 |
evClassNameTableTable of classes SEQUENCE OF EventClassConfig .1.3.6.1.4.1.3052.17.2.12.1.1 |
evClassNameEntryEntry for table of classes EventClassConfig .1.3.6.1.4.1.3052.17.2.12.1.1.1 |
evClassNameIndexIndex for table of classesro Integer32 .1.3.6.1.4.1.3052.17.2.12.1.1.1.1 |
evClassNameClass name for this slotrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.1.1.1.2 |
evReminderIntervalInterval (minutes) between EventSensor reminder eventsrw Integer32 .1.3.6.1.4.1.3052.17.2.12.1.2 |
evLog OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12.1.3 |
evLogEnableON/OFF enable event logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.1.3.1 |
evLogStoreAlarmON/OFF store data alarms in event logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.1.3.2 |
evLogMaxSizemax size (in KB) of event logrw Integer32 .1.3.6.1.4.1.3052.17.2.12.1.3.3 |
evLogStoreSensorON/OFF store EventSensor events in event logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.1.3.4 |
evLogTimeStampAlarmsON/OFF put timestamps on event log entriesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.1.3.5 |
evLogPrependNameON/OFF prepend data event name to data alarm records in event logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.1.3.6 |
evMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12.1.4 |
evMgmtReprocessNumber of sensors that have generated events since reset. Write this to reprocess each sensor's last generated event since reset. The value to write determines what kind of events should be reprocessed: 'all': all sensor events 'cc': cc events 'temperature': temperature events 'humidity': humidity events 'analog': analog input events 'fuel': fuel sensor events 'acpm': AC power monitor events 'battery': battery monitor eventsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.1.4.3 |
evSched1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12.5 |
evSched1EnableON/OFF enable this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.1 |
evSched1ActionsActions for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.2 |
evSched1MessageMessage for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.3 |
evSched1TrapNumTrap number for this scheduled eventrw Integer32 .1.3.6.1.4.1.3052.17.2.12.5.4 |
evSched1ClassClass for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.5 |
evSched1SundayTime on Sunday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.6 |
evSched1MondayTime on Monday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.7 |
evSched1TuesdayTime on Tuesday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.8 |
evSched1WednesdayTime on Wednesday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.9 |
evSched1ThursdayTime on Thursday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.10 |
evSched1FridayTime on Friday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.11 |
evSched1SaturdayTime on Saturday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.12 |
evSched1ExclusionsExclusions (space-separated MM/DD-formatted dates) for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.5.13 |
evSched2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12.6 |
evSched2EnableON/OFF enable this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.1 |
evSched2ActionsActions for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.2 |
evSched2MessageMessage for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.3 |
evSched2TrapNumTrap number for this scheduled eventrw Integer32 .1.3.6.1.4.1.3052.17.2.12.6.4 |
evSched2ClassClass for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.5 |
evSched2SundayTime on Sunday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.6 |
evSched2MondayTime on Monday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.7 |
evSched2TuesdayTime on Tuesday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.8 |
evSched2WednesdayTime on Wednesday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.9 |
evSched2ThursdayTime on Thursday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.10 |
evSched2FridayTime on Friday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.11 |
evSched2SaturdayTime on Saturday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.12 |
evSched2ExclusionsExclusions (space-separated MM/DD-formatted dates) for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.6.13 |
evShskLowTableTable of serial handshaking low events SEQUENCE OF SerialHandshakingLowEventConfig .1.3.6.1.4.1.3052.17.2.12.7 |
evShskLowEntryEntry for table of serial handshaking low events SerialHandshakingLowEventConfig .1.3.6.1.4.1.3052.17.2.12.7.1 |
evShskLowIndexIndex for table of serial handshaking low eventsro Integer32 .1.3.6.1.4.1.3052.17.2.12.7.1.1 |
evShskLowEnableON/OFF: enable the serial handshaking low event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.7.1.2 |
evShskLowActionsActions for the serial handshaking low event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.7.1.3 |
evShskLowMessageMessage for the serial handshaking low event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.7.1.4 |
evShskLowClassClass for the serial handshaking low event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.7.1.5 |
evShskLowTrapNumTrap number for the serial handshaking low event for this portrw Integer32 .1.3.6.1.4.1.3052.17.2.12.7.1.6 |
evShskHighTableTable of serial handshaking high events SEQUENCE OF SerialHandshakingHighEventConfig .1.3.6.1.4.1.3052.17.2.12.8 |
evShskHighEntryEntry for table of serial handshaking high events SerialHandshakingHighEventConfig .1.3.6.1.4.1.3052.17.2.12.8.1 |
evShskHighIndexIndex for table of serial handshaking high eventsro Integer32 .1.3.6.1.4.1.3052.17.2.12.8.1.1 |
evShskHighEnableON/OFF: enable the serial handshaking high event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.8.1.2 |
evShskHighActionsActions for the serial handshaking high event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.8.1.3 |
evShskHighMessageMessage for the serial handshaking high event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.8.1.4 |
evShskHighClassClass for the serial handshaking high event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.8.1.5 |
evShskHighTrapNumTrap number for the serial handshaking high event for this portrw Integer32 .1.3.6.1.4.1.3052.17.2.12.8.1.6 |
evNoSensor OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12.9 |
evNoSensorTimeoutTimeout (seconds) after which an EventSensor becomes unresponsive that this event is triggeredrw Integer32 .1.3.6.1.4.1.3052.17.2.12.9.1 |
evNoSensorActionsActions for no sensor eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.9.2 |
evNoSensorTrapNumTrap number for no sensor eventrw Integer32 .1.3.6.1.4.1.3052.17.2.12.9.3 |
evNoSensorClassClass for no sensor eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.9.4 |
fuelSensor OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12.11 |
fuelSensorGeneralTableThis table organizes general fuel sensor attributes. SEQUENCE OF FuelSensorConfigGeneral .1.3.6.1.4.1.3052.17.2.12.11.1 |
fsGenEntryEntry for fuel sensor general config table. FuelSensorConfigGeneral .1.3.6.1.4.1.3052.17.2.12.11.1.1 |
fsGenIndexWhich fuel sensor in the fuel sensor general config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.11.1.1.1 |
fsGenNameFuel sensor name.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.1.1.2 |
fsGenSensorTypeType of fuel sensor in use; NONE disables the fuel sensor.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.1.1.3 |
fsGenDistanceUnitDistance units in use when setting and indicating tank dimensions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.1.1.4 |
fsGenRawValueTopAnalog input reading corresponding to the SENSOR FULL point.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.1.1.5 |
fsGenTopOffsetDistance, in the specified distance unit, between the SENSOR FULL point and the TANK FULL point. The value is positive if the SENSOR FULL point is above the TANK FULL point, and negative if it is below.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.1.1.6 |
fsGenRawValueBottomAnalog input reading corresponding to the minimum fluid height measurable by the fuel sensor.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.1.1.7 |
fsGenBottomOffsetDistance, in the specified distance unit, between the SENSOR EMPTY point and the TANK EMPTY point. The value is positive if the SENSOR EMPTY point is above the TANK EMPTY point, and negative if it is below.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.1.1.8 |
fsGenInputESWhich eventsensor contains the analog input associated with this fuel sensor. Allowed values are 200 (for internal ES), or 1-16.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.1.1.9 |
fsGenInputPointWhich analog input point, on the specified eventsensor, that is associated with the fuel sensor.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.1.1.10 |
fsGenFilterAveragingFuel sensor filter averaging factor.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.1.1.11 |
fsGenSysrepEnableFuel sensor System Reporting enable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.1.1.12 |
fsGenSysrepThresholdFuel sensor System Reporting threshold (floating point value).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.1.1.13 |
fsGenSysrepLimitFuel sensor System Reporting limit.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.1.1.14 |
fsGenSysrepPackageFuel sensor System Reporting package number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.1.1.15 |
fsGenSysrepTypeFuel sensor ASM profile type.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.1.1.16 |
fuelSensorTankTableThis table organizes tank-specific fuel sensor attributes. SEQUENCE OF FuelSensorConfigTank .1.3.6.1.4.1.3052.17.2.12.11.2 |
fsTankEntryEntry for fuel sensor tank config table. FuelSensorConfigTank .1.3.6.1.4.1.3052.17.2.12.11.2.1 |
fsTankIndexWhich fuel sensor in the fuel sensor tank config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.11.2.1.1 |
fsTankHeightHeight of the tank, from the TANK EMPTY point to the TANK FULL point, in the specified distance unit (i.e. TANK HEIGHT). This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.2.1.2 |
fsTankDimATank dimension measurement A for certain tank profiles. For HORIZ OVAL, this is the length of the straight section. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.2.1.3 |
fsTankDimBTank dimension measurement B for certain tank profiles. For HORIZ OVAL, this is the radius of the curved section. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.2.1.4 |
fsTankVolumeHow many volume units the tank contains, when full. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.2.1.5 |
fsTankVolumeUnitName of the unit representing fluid volume in the tank. This is only used for display purposes; it does not affect the volume calculation.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.2.1.6 |
fsTankShapeThe shape of the fuel tank. A value of LINEAR produces a fluid volume reading that is directly proportional to fluid height. The HORIZ CYL and HORIZ OVAL settings use a hard-coded formula to calculate the volume. The CUSTOM setting uses a strapping table that must be configured as well (see fuelSensorCustomTankTable).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.2.1.7 |
fuelSensorCustomTankTableThis table organizes the custom tank strapping table. Each fuel sensor has a table of height/volume pairs in service only when the tank shape (fsTankShape) in CUSTOM. This allows the unit to calculate volumes for nonstandard tank shapes, to the degree that accurate height/volume measurements can be configured. This SNMP table has two indexes: the first for which fuel sensor and the second for which height/volume pair. SEQUENCE OF FuelSensorConfigCustomTankStrapping .1.3.6.1.4.1.3052.17.2.12.11.3 |
fsCustomTankEntryEntry for fuel sensor custom tank config table. FuelSensorConfigCustomTankStrapping .1.3.6.1.4.1.3052.17.2.12.11.3.1 |
fsCustomTankIndexFSWhich fuel sensor in the fuel sensor tank config table. This is the first of two indexes for this SNMP table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.11.3.1.1 |
fsCustomTankIndexDatumWhich hight/volume pair: there are 32 pairs per fuel sensor. This is the second of two indexes for this SNMP table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.11.3.1.2 |
fsCustomTankHeightHeight of custom tank height/volume pair. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.3.1.3 |
fsCustomTankVolumeVolume of custom tank height/volume pair. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.3.1.4 |
fuelSensorVolumeTableThis table organizes volume-event-specific fuel sensor attributes. SEQUENCE OF FuelSensorConfigVolume .1.3.6.1.4.1.3052.17.2.12.11.4 |
fsVolumeEntryEntry for fuel sensor volume event config table. FuelSensorConfigVolume .1.3.6.1.4.1.3052.17.2.12.11.4.1 |
fsVolumeIndexWhich fuel sensor in the fuel sensor volume event config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.11.4.1.1 |
fsVolumeEnableEnable fuel sensor volume events.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.2 |
fsVolumeDeadbandFuel sensor deadband (hysteresis). This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.3 |
fsVolumeVHighValueFuel sensor volume very high event threshold value. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.4 |
fsVolumeVHighActionsFuel sensor volume very high event threshold actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.5 |
fsVolumeVHighTrapNumFuel sensor volume very high event threshold trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.4.1.6 |
fsVolumeVHighClassFuel sensor volume very high event threshold class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.7 |
fsVolumeHighValueFuel sensor volume high event threshold value. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.8 |
fsVolumeHighActionsFuel sensor volume high event threshold actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.9 |
fsVolumeHighTrapNumFuel sensor volume high event threshold trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.4.1.10 |
fsVolumeHighClassFuel sensor volume high event threshold class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.11 |
fsVolumeNormalActionsFuel sensor volume return to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.12 |
fsVolumeNormalTrapNumFuel sensor volume return to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.4.1.13 |
fsVolumeNormalClassFuel sensor volume return to normal class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.14 |
fsVolumeLowValueFuel sensor volume low event threshold value. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.15 |
fsVolumeLowActionsFuel sensor volume low event threshold actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.16 |
fsVolumeLowTrapNumFuel sensor volume low event threshold trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.4.1.17 |
fsVolumeLowClassFuel sensor volume low event threshold class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.18 |
fsVolumeVLowValueFuel sensor volume very low event threshold value. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.19 |
fsVolumeVLowActionsFuel sensor volume very low event threshold actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.20 |
fsVolumeVLowTrapNumFuel sensor volume very low event threshold trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.4.1.21 |
fsVolumeVLowClassFuel sensor volume very low event threshold class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.4.1.22 |
fuelSensorDisconnectTableThis table organizes disconnect-event-specific fuel sensor attributes. SEQUENCE OF FuelSensorConfigDisconnect .1.3.6.1.4.1.3052.17.2.12.11.5 |
fsDiscEntryEntry for fuel sensor disconnect event config table. FuelSensorConfigDisconnect .1.3.6.1.4.1.3052.17.2.12.11.5.1 |
fsDiscIndexWhich fuel sensor in the fuel sensor disconnect event config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.11.5.1.1 |
fsDiscEnableFuel sensor disconnect event enable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.5.1.2 |
fsDiscHighValueHigh end of input value range when fuel sensor is disconnected. This is in the units of the analog input value.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.5.1.3 |
fsDiscLowValueLow end of input value range when fuel sensor is disconnected. This is in the units of the analog input value.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.5.1.4 |
fsDiscActionsFuel sensor disconnect event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.5.1.5 |
fsDiscTrapNumFuel sensor disconnect event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.5.1.6 |
fsDiscClassFuel sensor disconnect event class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.5.1.7 |
fsDiscNormalActionsFuel sensor disconnect return to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.5.1.8 |
fsDiscNormalTrapNumFuel sensor disconnect return to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.5.1.9 |
fsDiscNormalClassFuel sensor disconnect return to normal class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.5.1.10 |
fuelSensorSuddenChangeTableThis table organizes sudden-change-event-specific fuel sensor attributes. SEQUENCE OF FuelSensorConfigSuddenChange .1.3.6.1.4.1.3052.17.2.12.11.6 |
fsSuddenChangeEntryEntry for fuel sensor sudden change event config table. FuelSensorConfigSuddenChange .1.3.6.1.4.1.3052.17.2.12.11.6.1 |
fsSuddenChangeIndexWhich fuel sensor in the fuel sensor disconnect event config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.11.6.1.1 |
fsSuddenChangeEnableFuel volume sudden change event enable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.6.1.2 |
fsSuddenChangeTimeFuel volume sudden change event time (minutes): what duration defines 'sudden'.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.6.1.3 |
fsSuddenChangeAmplitudeFuel volume sudden change event amplitude: what amount (in fuel volume units) over the duration (fsSuddenChangeTime) defines enough change.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.6.1.4 |
fsSuddenChangeActionsFuel volume sudden change event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.6.1.5 |
fsSuddenChangeTrapNumFuel volume sudden change event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.6.1.6 |
fsSuddenChangeClassFuel volume sudden change event class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.6.1.7 |
fuelSensorSlowChangeTableThis table organizes slow-change-event-specific fuel sensor attributes. SEQUENCE OF FuelSensorConfigSlowChange .1.3.6.1.4.1.3052.17.2.12.11.7 |
fsSlowChangeEntryEntry for fuel sensor slow change event config table. FuelSensorConfigSlowChange .1.3.6.1.4.1.3052.17.2.12.11.7.1 |
fsSlowChangeIndexWhich fuel sensor in the fuel sensor disconnect event config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.11.7.1.1 |
fsSlowChangeEnableFuel volume slow change event enable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.7.1.2 |
fsSlowChangeTimeFuel volume slow change event time (minutes): what duration defines 'slow'.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.7.1.3 |
fsSlowChangeAmplitudeFuel volume slow change event amplitude: what amount (in fuel volume units) over the duration (fsSlowChangeTime) defines enough change.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.7.1.4 |
fsSlowChangeActionsFuel volume slow change event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.7.1.5 |
fsSlowChangeTrapNumFuel volume slow change event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.11.7.1.6 |
fsSlowChangeClassFuel volume slow change event class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.11.7.1.7 |
acPowerMonitor OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12.12 |
acpmGeneralTableThis table organizes general AC power monitor attributes. SEQUENCE OF ACPMConfigGeneral .1.3.6.1.4.1.3052.17.2.12.12.1 |
acpmGenEntryEntry for AC power monitor general config table. ACPMConfigGeneral .1.3.6.1.4.1.3052.17.2.12.12.1.1 |
acpmGenIndexWhich AC power monitor in the AC power monitor general config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.12.1.1.1 |
acpmGenDeviceModel of the AC power monitor device. The unit needs this setting to know which registers to poll for the various data items, among other things.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.1.1.2 |
acpmGenNameName for the AC power monitor device.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.1.1.3 |
acpmGenAddressModbus address of the AC power monitor device.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.1.1.4 |
acpmGenPtRatioRatio of secondary turns to primary turns on potential transformers (PT).rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.1.1.5 |
acpmGenCtRatioRatio of secondary turns to primary turns on current transformers (CT).rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.1.1.6 |
acpmGenPowerTypeType of power being monitored.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.1.1.7 |
acpmGenSysrepPackageSystem reporting package number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.1.1.8 |
acpmGenSysrepTypeASM profile type.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.1.1.9 |
acpmAvgVoltageTableThis table organizes AC power monitor average voltage attributes. SEQUENCE OF ACPMConfigAvgVoltage .1.3.6.1.4.1.3052.17.2.12.12.2 |
acpmAvgVoltageEntryEntry for AC power monitor average voltage config table. ACPMConfigAvgVoltage .1.3.6.1.4.1.3052.17.2.12.12.2.1 |
acpmAvgVoltageIndexWhich AC power monitor in the AC power monitor average voltage config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.12.2.1.1 |
acpmAvgVoltageEnableEnable AC power monitor average voltage events.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.2 |
acpmAvgVoltageDeadbandDeadband (hysteresis) for average voltage event. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.3 |
acpmAvgVoltageVHighValueVery high event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.4 |
acpmAvgVoltageVHighActionsVery high event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.5 |
acpmAvgVoltageVHighTrapNumVery high event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.2.1.6 |
acpmAvgVoltageVHighClassVery high event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.7 |
acpmAvgVoltageHighValueHigh event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.8 |
acpmAvgVoltageHighActionsHigh event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.9 |
acpmAvgVoltageHighTrapNumHigh event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.2.1.10 |
acpmAvgVoltageHighClassHigh event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.11 |
acpmAvgVoltageNormalActionsReturn to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.12 |
acpmAvgVoltageNormalTrapNumReturn to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.2.1.13 |
acpmAvgVoltageNormalClassReturn to normal class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.14 |
acpmAvgVoltageLowValueLow event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.15 |
acpmAvgVoltageLowActionsLow event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.16 |
acpmAvgVoltageLowTrapNumLow event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.2.1.17 |
acpmAvgVoltageLowClassLow event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.18 |
acpmAvgVoltageVLowValueVery low event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.19 |
acpmAvgVoltageVLowActionsVery low event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.20 |
acpmAvgVoltageVLowTrapNumVery low event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.2.1.21 |
acpmAvgVoltageVLowClassVery low event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.22 |
acpmAvgVoltageSysrepEnableSystem reporting enable for average voltage telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.23 |
acpmAvgVoltageSysrepThresholdSystem reporting threshold for average voltage telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.2.1.24 |
acpmAvgVoltageSysrepLimitSystem reporting limit for average voltage telemetry.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.2.1.25 |
acpmAvgCurrentTableThis table organizes AC power monitor average current attributes. SEQUENCE OF ACPMConfigAvgCurrent .1.3.6.1.4.1.3052.17.2.12.12.3 |
acpmAvgCurrentEntryEntry for AC power monitor average current config table. ACPMConfigAvgCurrent .1.3.6.1.4.1.3052.17.2.12.12.3.1 |
acpmAvgCurrentIndexWhich AC power monitor in the AC power monitor average current config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.12.3.1.1 |
acpmAvgCurrentEnableEnable AC power monitor average current events.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.2 |
acpmAvgCurrentDeadbandDeadband (hysteresis) for average current event. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.3 |
acpmAvgCurrentVHighValueVery high event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.4 |
acpmAvgCurrentVHighActionsVery high event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.5 |
acpmAvgCurrentVHighTrapNumVery high event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.3.1.6 |
acpmAvgCurrentVHighClassVery high event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.7 |
acpmAvgCurrentHighValueHigh event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.8 |
acpmAvgCurrentHighActionsHigh event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.9 |
acpmAvgCurrentHighTrapNumHigh event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.3.1.10 |
acpmAvgCurrentHighClassHigh event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.11 |
acpmAvgCurrentNormalActionsReturn to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.12 |
acpmAvgCurrentNormalTrapNumReturn to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.3.1.13 |
acpmAvgCurrentNormalClassReturn to normal class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.14 |
acpmAvgCurrentLowValueLow event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.15 |
acpmAvgCurrentLowActionsLow event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.16 |
acpmAvgCurrentLowTrapNumLow event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.3.1.17 |
acpmAvgCurrentLowClassLow event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.18 |
acpmAvgCurrentVLowValueVery low event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.19 |
acpmAvgCurrentVLowActionsVery low event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.20 |
acpmAvgCurrentVLowTrapNumVery low event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.3.1.21 |
acpmAvgCurrentVLowClassVery low event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.22 |
acpmAvgCurrentSysrepEnableSystem reporting enable for average current telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.23 |
acpmAvgCurrentSysrepThresholdSystem reporting threshold for average current telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.3.1.24 |
acpmAvgCurrentSysrepLimitSystem reporting limit for average current telemetry.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.3.1.25 |
acpmFreqTableThis table organizes AC power monitor frequency attributes. SEQUENCE OF ACPMConfigFreq .1.3.6.1.4.1.3052.17.2.12.12.4 |
acpmFreqEntryEntry for AC power monitor frequency config table. ACPMConfigFreq .1.3.6.1.4.1.3052.17.2.12.12.4.1 |
acpmFreqIndexWhich AC power monitor in the AC power monitor frequency config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.12.4.1.1 |
acpmFreqEnableEnable AC power monitor frequency events.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.2 |
acpmFreqDeadbandDeadband (hysteresis) for frequency event. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.3 |
acpmFreqVHighValueVery high event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.4 |
acpmFreqVHighActionsVery high event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.5 |
acpmFreqVHighTrapNumVery high event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.4.1.6 |
acpmFreqVHighClassVery high event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.7 |
acpmFreqHighValueHigh event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.8 |
acpmFreqHighActionsHigh event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.9 |
acpmFreqHighTrapNumHigh event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.4.1.10 |
acpmFreqHighClassHigh event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.11 |
acpmFreqNormalActionsReturn to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.12 |
acpmFreqNormalTrapNumReturn to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.4.1.13 |
acpmFreqNormalClassReturn to normal class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.14 |
acpmFreqLowValueLow event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.15 |
acpmFreqLowActionsLow event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.16 |
acpmFreqLowTrapNumLow event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.4.1.17 |
acpmFreqLowClassLow event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.18 |
acpmFreqVLowValueVery low event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.19 |
acpmFreqVLowActionsVery low event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.20 |
acpmFreqVLowTrapNumVery low event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.4.1.21 |
acpmFreqVLowClassVery low event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.22 |
acpmFreqSysrepEnableSystem reporting enable for frequency telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.23 |
acpmFreqSysrepThresholdSystem reporting threshold for frequency telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.4.1.24 |
acpmFreqSysrepLimitSystem reporting limit for frequency telemetry.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.4.1.25 |
acpmTotalRealPowerTableThis table organizes AC power monitor total real power attributes. SEQUENCE OF ACPMConfigTRP .1.3.6.1.4.1.3052.17.2.12.12.5 |
acpmTRPEntryEntry for AC power monitor total real power config table. ACPMConfigTRP .1.3.6.1.4.1.3052.17.2.12.12.5.1 |
acpmTRPIndexWhich AC power monitor in the AC power monitor total real power config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.12.5.1.1 |
acpmTRPEnableEnable AC power monitor total real power events.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.2 |
acpmTRPDeadbandDeadband (hysteresis) for total real power event. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.3 |
acpmTRPVHighValueVery high event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.4 |
acpmTRPVHighActionsVery high event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.5 |
acpmTRPVHighTrapNumVery high event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.5.1.6 |
acpmTRPVHighClassVery high event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.7 |
acpmTRPHighValueHigh event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.8 |
acpmTRPHighActionsHigh event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.9 |
acpmTRPHighTrapNumHigh event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.5.1.10 |
acpmTRPHighClassHigh event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.11 |
acpmTRPNormalActionsReturn to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.12 |
acpmTRPNormalTrapNumReturn to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.5.1.13 |
acpmTRPNormalClassReturn to normal class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.14 |
acpmTRPLowValueLow event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.15 |
acpmTRPLowActionsLow event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.16 |
acpmTRPLowTrapNumLow event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.5.1.17 |
acpmTRPLowClassLow event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.18 |
acpmTRPVLowValueVery low event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.19 |
acpmTRPVLowActionsVery low event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.20 |
acpmTRPVLowTrapNumVery low event trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.5.1.21 |
acpmTRPVLowClassVery low event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.22 |
acpmTRPSysrepEnableSystem reporting enable for total real power telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.23 |
acpmTRPSysrepThresholdSystem reporting threshold for total real power telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.5.1.24 |
acpmTRPSysrepLimitSystem reporting limit for total real power telemetry.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.5.1.25 |
acpmDisconnectTableThis table organizes AC power monitor device disconnect event attributes. SEQUENCE OF ACPMConfigDisconnect .1.3.6.1.4.1.3052.17.2.12.12.6 |
acpmDisconnectEntryEntry for AC power monitor device disconnect event config table. ACPMConfigDisconnect .1.3.6.1.4.1.3052.17.2.12.12.6.1 |
acpmDisconnectIndexWhich AC power monitor in the AC power monitor device disconnect event config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.12.6.1.1 |
acpmDisconnectEnableEnable AC power monitor device disconnect event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.6.1.2 |
acpmDisconnectActionsActions for disconnect event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.6.1.3 |
acpmDisconnectTrapNumTrap number for disconnect event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.6.1.4 |
acpmDisconnectClassClass for disconnect event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.6.1.5 |
acpmDisconnectNormalActionsActions for disconnect return to normal event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.6.1.6 |
acpmDisconnectNormalTrapNumTrap number for disconnect return to normal event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.6.1.7 |
acpmDisconnectNormalClassClass for disconnect return to normal event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.6.1.8 |
acpmTotalPowerFactorTableThis table organizes AC power monitor device total power factor event attributes. SEQUENCE OF ACPMConfigTotalPowerFactor .1.3.6.1.4.1.3052.17.2.12.12.7 |
acpmTPFEntryEntry for AC power monitor device total power factor event config table. ACPMConfigTotalPowerFactor .1.3.6.1.4.1.3052.17.2.12.12.7.1 |
acpmTPFIndexWhich AC power monitor in the AC power monitor device disconnect event config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.12.7.1.1 |
acpmTPFEnableEnable AC power monitor device disconnect event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.2 |
acpmTPFDeadbandDeadband (hysteresis).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.3 |
acpmTPFNormalActionsNormal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.4 |
acpmTPFNormalTrapNumNormal trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.7.1.5 |
acpmTPFNormalClassNormal class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.6 |
acpmTPFLowValueLow threshold.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.7 |
acpmTPFLowActionsLow actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.8 |
acpmTPFLowTrapNumLow trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.7.1.9 |
acpmTPFLowClassLow class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.10 |
acpmTPFVLowValueVery Low threshold.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.11 |
acpmTPFVLowActionsVery Low actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.12 |
acpmTPFVLowTrapNumVery Low trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.7.1.13 |
acpmTPFVLowClassVery Low class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.14 |
acpmTPFSysrepEnableSystem reporting enable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.15 |
acpmTPFSysrepThresholdSystem reporting threshold.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.12.7.1.16 |
acpmTPFSysrepLimitSystem reporting limit.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.12.7.1.17 |
batteryMonitor OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12.14 |
batteryMonitorGeneralTableThis table organizes general battery monitor attributes. SEQUENCE OF BatteryMonitorConfigGeneral .1.3.6.1.4.1.3052.17.2.12.14.1 |
bmGenEntryEntry for battery monitor general config table. BatteryMonitorConfigGeneral .1.3.6.1.4.1.3052.17.2.12.14.1.1 |
bmGenIndexWhich battery monitor in the battery monitor general config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.14.1.1.1 |
bmGenEnableWhich battery monitor in the battery monitor general config table.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.1.1.2 |
bmGenNameName for this battery monitor.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.1.1.3 |
bmGenBatteryQuantityNumber of batteries in the string.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.1.1.4 |
bmGenBatteryCapacityCapacity of the individual batteries in the string, in amp-hours. A single value applies to all batteries; that is, they are assumed to be all of the same capacity.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.1.1.5 |
bmGenBatteryNominalVoltageNominal voltage of the individual batteries in the string, in volts. A single value applies to all batteres; that is, they are assumed to be all of the same voltage. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.1.1.6 |
bmGenSysrepPackageSystem reporting package number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.1.1.7 |
bmGenSysrepTypeSystem reporting ASM profile type.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.1.1.8 |
batteryMonitorDeviceTableThis table organizes temperature battery monitor attributes. SEQUENCE OF BatteryMonitorConfigDevice .1.3.6.1.4.1.3052.17.2.12.14.2 |
bmDeviceEntryEntry for battery monitor temperature config table. BatteryMonitorConfigDevice .1.3.6.1.4.1.3052.17.2.12.14.2.1 |
bmDeviceIndexWhich battery monitor in the battery monitor device config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.14.2.1.1 |
bmDeviceTypeThe type of hardware battery monitor unit associated with this battery monitor.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.2.1.2 |
bmDeviceESThe ES index of the hardware battery monitor unit associated with this battery monitor. This setting only pertains to the ES-BMU.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.2.1.3 |
bmDeviceIPThe IP address of the hardware battery monitor unit associated with this battery monitor.rw IpAddress .1.3.6.1.4.1.3052.17.2.12.14.2.1.4 |
bmDeviceReadcomThe SNMP read community of the hardware battery monitor unit associated with this battery monitor.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.2.1.5 |
bmDeviceInputStringWhich string on the hardware battery monitor unit is associated with this battery monitor.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.2.1.6 |
bmDeviceCTSizeThe rating of the DC current sensor, in amperes. If this value is set to 0, then string current will not be measured. This setting only pertains to the ES-BMU.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.2.1.7 |
batteryMonitorTempTableThis table organizes temperature battery monitor attributes. SEQUENCE OF BatteryMonitorConfigTemp .1.3.6.1.4.1.3052.17.2.12.14.3 |
bmTempEntryEntry for battery monitor temperature config table. BatteryMonitorConfigTemp .1.3.6.1.4.1.3052.17.2.12.14.3.1 |
bmTempIndexWhich battery monitor in the battery monitor temperature config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.14.3.1.1 |
bmTempEnableEnable/disable temperature event. This event is based on the average temperature of the jars in the string.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.2 |
bmTempDeadbandDeadband in degrees F or C, depending on scale setting of sensor referenced by bmGenDeviceES. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.3 |
bmTempScaleTemperature scale; this affects how temperature values are represented, and also how the temperature alarm thresholds and deadbands are interpreted.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.4 |
bmTempHighValueVery high event threshold in degrees F or C, depending on scale setting referenced by bmGenDeviceES. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.5 |
bmTempHighActionsActions for very high temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.6 |
bmTempHighTrapNumTrap number for high temperature event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.3.1.7 |
bmTempHighClassClass for high temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.8 |
bmTempNormalActionsActions for return to normal temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.9 |
bmTempNormalTrapNumTrap number for return to normal temperature event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.3.1.10 |
bmTempNormalClassClass for return to normal temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.11 |
bmTempLowValueLow event threshold in degrees F or C, depending on scale setting. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.12 |
bmTempLowActionsActions for low temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.13 |
bmTempLowTrapNumTrap number for low temperature event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.3.1.14 |
bmTempLowClassTrap number for low temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.15 |
bmTempSysrepEnableSystem reporting enable for temperature telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.16 |
bmTempSysrepThresholdSystem reporting threshold for temperature telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.3.1.17 |
bmTempSysrepLimitSystem reporting limit for temperature telemetry.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.3.1.18 |
batteryMonitorDiffTempTableThis table organizes differential temperature battery monitor attributes. SEQUENCE OF BatteryMonitorConfigDiffTemp .1.3.6.1.4.1.3052.17.2.12.14.4 |
bmDiffTempEntryEntry for battery monitor differential temperature config table. BatteryMonitorConfigDiffTemp .1.3.6.1.4.1.3052.17.2.12.14.4.1 |
bmDiffTempIndexWhich battery monitor in the battery monitor differential temperature config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.14.4.1.1 |
bmDiffTempEnableEnable/disable differential temperature event. This event is based on the differential between the average temperature of the batteries in the string, and ambient temperature (ambient - string temperature).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.4.1.2 |
bmDiffTempDeadbandDeadband in degrees F or C, depending on scale setting.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.4.1.3 |
bmDiffTempVHighValueVery high event threshold in degrees F or C, depending on scale setting.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.4.1.4 |
bmDiffTempVHighActionsActions for very high differential temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.4.1.5 |
bmDiffTempVHighTrapNumTrap number for very high differential temperature event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.4.1.6 |
bmDiffTempVHighClassClass for very high differential temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.4.1.7 |
bmDiffTempHighValueHigh event threshold in degrees F or C, depending on scale setting.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.4.1.8 |
bmDiffTempHighActionsActions for high differential temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.4.1.9 |
bmDiffTempHighTrapNumTrap number for high differential temperature event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.4.1.10 |
bmDiffTempHighClassClass for high differential temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.4.1.11 |
bmDiffTempNormalActionsActions for return to normal differential temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.4.1.12 |
bmDiffTempNormalTrapNumTrap number for return to normal differential temperature event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.4.1.13 |
bmDiffTempNormalClassClass for return to normal differential temperature event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.4.1.14 |
bmDiffTempSysrepEnableSystem reporting enable for differential temperature telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.4.1.15 |
bmDiffTempSysrepThresholdSystem reporting threshold for differential temperature telemetry.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.4.1.16 |
bmDiffTempSysrepLimitSystem reporting limit for differential temperature telemetry.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.4.1.17 |
batteryMonitorVoltageTableThis table organizes battery monitor voltage attributes. SEQUENCE OF BatteryMonitorConfigVoltage .1.3.6.1.4.1.3052.17.2.12.14.5 |
bmVoltageEntryEntry for battery monitor voltage config table. BatteryMonitorConfigVoltage .1.3.6.1.4.1.3052.17.2.12.14.5.1 |
bmVoltageIndexWhich battery monitor in the battery monitor voltage config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.14.5.1.1 |
bmVoltageEnableEnable/disable voltage event. This event is based on the total voltage output of the batteries in the string.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.2 |
bmVoltageDeadbandDeadband in volts. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.3 |
bmVoltageVHighValueVery high event threshold, in volts. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.4 |
bmVoltageVHighActionsActions for very high voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.5 |
bmVoltageVHighTrapNumTrap number for very high voltage event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.5.1.6 |
bmVoltageVHighClassClass for very high voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.7 |
bmVoltageHighValueHigh event threshold, in volts. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.8 |
bmVoltageHighActionsActions for high voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.9 |
bmVoltageHighTrapNumTrap number for high voltage event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.5.1.10 |
bmVoltageHighClassClass for high voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.11 |
bmVoltageNormalActionsActions for return to normal voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.12 |
bmVoltageNormalTrapNumTrap number for return to normal voltage event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.5.1.13 |
bmVoltageNormalClassClass for return to normal voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.14 |
bmVoltageLowValueLow event threshold, in volts. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.15 |
bmVoltageLowActionsActions for low voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.16 |
bmVoltageLowTrapNumTrap number for low voltage event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.5.1.17 |
bmVoltageLowClassClass for low voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.18 |
bmVoltageVLowValueVery Low event threshold, in volts. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.19 |
bmVoltageVLowActionsActions for very low voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.20 |
bmVoltageVLowTrapNumTrap number for very low voltage event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.5.1.21 |
bmVoltageVLowClassClass for very low voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.22 |
bmVoltageSysrepEnableSystem reporting enable for voltage telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.23 |
bmVoltageSysrepThresholdSystem reporting threshold for voltage telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.5.1.24 |
bmVoltageSysrepLimitSystem reporting limit for voltage telemetry.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.5.1.25 |
batteryMonitorDiffVoltTableThis table organizes differential voltage battery monitor attributes. SEQUENCE OF BatteryMonitorConfigDiffVolt .1.3.6.1.4.1.3052.17.2.12.14.6 |
bmDiffVoltEntryEntry for battery monitor differential voltage config table. BatteryMonitorConfigDiffVolt .1.3.6.1.4.1.3052.17.2.12.14.6.1 |
bmDiffVoltIndexWhich battery monitor in the battery monitor differential voltage config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.14.6.1.1 |
bmDiffVoltEnableEnable/disable differential voltage event. This event is based on the differential between the highest and lowest jar voltages within the string.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.2 |
bmDiffVoltDeadbandDeadband in volts.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.3 |
bmDiffVoltVHighValueVery high event threshold in volts. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.4 |
bmDiffVoltVHighActionsActions for very high differential voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.5 |
bmDiffVoltVHighTrapNumTrap number for very high differential voltage event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.6.1.6 |
bmDiffVoltVHighClassClass for very high differential voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.7 |
bmDiffVoltHighValueHigh event threshold in volts. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.8 |
bmDiffVoltHighActionsActions for high differential voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.9 |
bmDiffVoltHighTrapNumTrap number for high differential voltage event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.6.1.10 |
bmDiffVoltHighClassClass for high differential voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.11 |
bmDiffVoltNormalActionsActions for return to normal differential voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.12 |
bmDiffVoltNormalTrapNumTrap number for return to normal differential voltage event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.6.1.13 |
bmDiffVoltNormalClassClass for return to normal differential voltage event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.14 |
bmDiffVoltSysrepEnableSystem reporting enable for differential voltage telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.15 |
bmDiffVoltSysrepThresholdSystem reporting threshold for differential voltage telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.6.1.16 |
bmDiffVoltSysrepLimitSystem reporting limit for differential voltage telemetry.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.6.1.17 |
batteryMonitorChargingCurrentTableThis table organizes battery monitor charging current attributes. SEQUENCE OF BatteryMonitorConfigChargingCurrent .1.3.6.1.4.1.3052.17.2.12.14.7 |
bmChargingCurrentEntryEntry for battery monitor differential charging current config table. BatteryMonitorConfigChargingCurrent .1.3.6.1.4.1.3052.17.2.12.14.7.1 |
bmChargingCurrentIndexWhich battery monitor in the battery monitor charging current config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.14.7.1.1 |
bmChargingCurrentEnableEnable/disable charging current event. This event is based on positive current flow (i.e. current flowing into the battery string).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.2 |
bmChargingCurrentDeadbandDeadband in amperes. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.3 |
bmChargingCurrentVHighValueVery high event threshold, in volts. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.4 |
bmChargingCurrentVHighActionsActions for very high charging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.5 |
bmChargingCurrentVHighTrapNumTrap number for very high charging current event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.7.1.6 |
bmChargingCurrentVHighClassClass for very high charging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.7 |
bmChargingCurrentHighValueHigh event threshold, in volts. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.8 |
bmChargingCurrentHighActionsActions for high charging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.9 |
bmChargingCurrentHighTrapNumTrap number for high charging current event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.7.1.10 |
bmChargingCurrentHighClassClass for high charging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.11 |
bmChargingCurrentNormalActionsActions for return to normal charging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.12 |
bmChargingCurrentNormalTrapNumTrap number for return to normal charging current event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.7.1.13 |
bmChargingCurrentNormalClassClass for return to normal charging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.14 |
bmChargingCurrentSysrepEnableSystem reporting enable for charging current telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.15 |
bmChargingCurrentSysrepThresholdSystem reporting threshold for charging current telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.7.1.16 |
bmChargingCurrentSysrepLimitSystem reporting limit for charging current telemetry.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.7.1.17 |
batteryMonitorDischargingCurrentTableThis table organizes battery monitor discharging current attributes. SEQUENCE OF BatteryMonitorConfigDischargingCurrent .1.3.6.1.4.1.3052.17.2.12.14.8 |
bmDischargingCurrentEntryEntry for battery monitor differential discharging current config table. BatteryMonitorConfigDischargingCurrent .1.3.6.1.4.1.3052.17.2.12.14.8.1 |
bmDischargingCurrentIndexWhich battery monitor in the battery monitor discharging current config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.14.8.1.1 |
bmDischargingCurrentEnableEnable/disable discharging current event. This event is based on positive current flow (i.e. current flowing into the battery string).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.2 |
bmDischargingCurrentDeadbandDeadband in amperes. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.3 |
bmDischargingCurrentVHighValueVery high event threshold, in volts. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.4 |
bmDischargingCurrentVHighActionsActions for very high discharging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.5 |
bmDischargingCurrentVHighTrapNumTrap number for very high discharging current event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.8.1.6 |
bmDischargingCurrentVHighClassClass for very high discharging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.7 |
bmDischargingCurrentHighValueHigh event threshold, in volts. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.8 |
bmDischargingCurrentHighActionsActions for high discharging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.9 |
bmDischargingCurrentHighTrapNumTrap number for high discharging current event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.8.1.10 |
bmDischargingCurrentHighClassClass for high discharging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.11 |
bmDischargingCurrentNormalActionsActions for return to normal discharging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.12 |
bmDischargingCurrentNormalTrapNumTrap number for return to normal discharging current event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.8.1.13 |
bmDischargingCurrentNormalClassClass for return to normal discharging current event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.14 |
bmDischargingCurrentSysrepEnableSystem reporting enable for discharging current telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.15 |
bmDischargingCurrentSysrepThresholdSystem reporting threshold for discharging current telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.8.1.16 |
bmDischargingCurrentSysrepLimitSystem reporting limit for discharging current telemetry.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.8.1.17 |
batteryMonitorChargeLevelTableThis table organizes battery monitor charge level attributes. SEQUENCE OF BatteryMonitorConfigChargeLevel .1.3.6.1.4.1.3052.17.2.12.14.9 |
bmChargeLevelEntryEntry for battery monitor charge level config table. BatteryMonitorConfigChargeLevel .1.3.6.1.4.1.3052.17.2.12.14.9.1 |
bmChargeLevelIndexWhich battery monitor in the battery monitor charge level config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.14.9.1.1 |
bmChargeLevelEnableEnable/disable charge level event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.9.1.2 |
bmChargeLevelNormalActionsActions for return to normal charge level event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.9.1.3 |
bmChargeLevelNormalTrapNumTrap number for return to normal charge level event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.9.1.4 |
bmChargeLevelNormalClassClass for return to normal charge level event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.9.1.5 |
bmChargeLevelLowActionsActions for low charge level event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.9.1.6 |
bmChargeLevelLowTrapNumTrap number for low charge level event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.9.1.7 |
bmChargeLevelLowClassClass for low charge level event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.9.1.8 |
bmChargeLevelVLowActionsActions for very low charge level event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.9.1.9 |
bmChargeLevelVLowTrapNumTrap number for very low charge level event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.9.1.10 |
bmChargeLevelVLowClassClass for very low charge level event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.9.1.11 |
bmChargeLevelSysrepEnableSystem reporting enable for charge level telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.9.1.12 |
batteryMonitorJarHealthTableThis table organizes battery monitor jar health attributes. SEQUENCE OF BatteryMonitorConfigJarHealth .1.3.6.1.4.1.3052.17.2.12.14.10 |
bmJarHealthEntryEntry for battery monitor jar health config table. BatteryMonitorConfigJarHealth .1.3.6.1.4.1.3052.17.2.12.14.10.1 |
bmJarHealthIndexWhich battery monitor in the battery monitor jar health config table.ro Integer32 .1.3.6.1.4.1.3052.17.2.12.14.10.1.1 |
bmJarHealthEnableEnable/disable jar health event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.10.1.2 |
bmJarHealthNormalActionsActions for return to normal jar health event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.10.1.3 |
bmJarHealthNormalTrapNumTrap number for return to normal jar health event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.10.1.4 |
bmJarHealthNormalClassClass for return to normal jar health event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.10.1.5 |
bmJarHealthLowActionsActions for low jar health event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.10.1.6 |
bmJarHealthLowTrapNumTrap number for low jar health event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.10.1.7 |
bmJarHealthLowClassClass for low jar health event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.10.1.8 |
bmJarHealthVLowActionsActions for very low jar health event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.10.1.9 |
bmJarHealthVLowTrapNumTrap number for very low jar health event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.14.10.1.10 |
bmJarHealthVLowClassClass for very low jar health event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.10.1.11 |
bmJarHealthSysrepEnableSystem reporting enable for jar health telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.14.10.1.12 |
evReset OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12.16 |
evResetEnableEnable/disable reset event. This event is triggered when the unit finishes booting.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.16.1 |
evResetDelayNumber of seconds to wait after unit finishes booting before triggering the reset event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.16.2 |
evResetActionsActions for reset event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.16.3 |
evResetMessageMessage for reset event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.16.4 |
evResetTrapnumTrap number for reset event.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.16.5 |
evResetClassClass (severity) for reset event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.16.6 |
evGlobal OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.12.18 |
evGlobalActionsGlobal event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.12.18.2 |
evGlobalTrapnumGlobal trap number.rw Integer32 .1.3.6.1.4.1.3052.17.2.12.18.3 |
action OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.14 |
actionSched OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.14.3 |
actionSchedEnableON/OFF enable action schedulerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.14.3.1 |
actionSchedBeginaction schedule begin time (HH:MM)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.14.3.2 |
actionSchedEndaction schedule end time (HH:MM)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.14.3.3 |
actionSchedWeekdaysOnlyON/OFF whether the action schedule applies to weekdays only (ON) or all days (OFF)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.14.3.4 |
actionAsentria OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.14.4 |
actionAsentriaRequireAckON/OFF Asentria action requires an ack from the receiverrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.14.4.1 |
actionAsentriaVersionversion 1.0 or 1.1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.14.4.2 |
actionAsentriaTCPPortTCP port used for TCP-based Asentria alarmsrw Integer32 .1.3.6.1.4.1.3052.17.2.14.4.3 |
actionHostTableTable of network hosts to use for network-based actions SEQUENCE OF ActionHostConfig .1.3.6.1.4.1.3052.17.2.14.6 |
actionHostEntryEntry for table of network hosts to use for network-based actions ActionHostConfig .1.3.6.1.4.1.3052.17.2.14.6.1 |
actionHostIndexIndex for table of network hosts to use for network-based actionsro Integer32 .1.3.6.1.4.1.3052.17.2.14.6.1.1 |
actionHostHostname/IP address used as destination for network-based action (e.g., trap)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.14.6.1.2 |
actionEmailTableTable of email addresses to use for email actions SEQUENCE OF ActionEmailConfig .1.3.6.1.4.1.3052.17.2.14.7 |
actionEmailEntryEntry for table of email addresses to use for email actions ActionEmailConfig .1.3.6.1.4.1.3052.17.2.14.7.1 |
actionEmailIndexIndex for table of email addresses to use for email actionsro Integer32 .1.3.6.1.4.1.3052.17.2.14.7.1.1 |
actionEmailemail addressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.14.7.1.2 |
actionParseErrorWhen a user attempts to configure an invalid action setting/ object, this object says why it was invalid.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.14.8 |
sys OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.16 |
sysTime OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.16.1 |
sysTimeAutoDSTON/OFF automatically adjust for Daylight Savings Timerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.1.1 |
sysTimeGMTOffsetAbsolute value of offset (hours) from GMT of the timezonerw Integer32 .1.3.6.1.4.1.3052.17.2.16.1.2 |
sysTimeGMTDirectionDirection (AHEAD/BEHIND) of timezone relative to GMTrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.1.3 |
sysTimeNet OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.16.1.4 |
sysTimeNetEnableNetwork time moderw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.1.4.1 |
sysTimeNetHostTableTable of hosts to use for network time services SEQUENCE OF NetworkTimeHostConfig .1.3.6.1.4.1.3052.17.2.16.1.4.2 |
sysTimeNetHostEntryEntry for table of hosts to use for network time services NetworkTimeHostConfig .1.3.6.1.4.1.3052.17.2.16.1.4.2.1 |
sysTimeNetHostIndexIndex for table of hosts to use for network time servicesro Integer32 .1.3.6.1.4.1.3052.17.2.16.1.4.2.1.1 |
sysTimeNetHosthost to use for network time servicesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.1.4.2.1.2 |
sysPT OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.16.2 |
sysPTTimeoutTimeout (minutes) of inactivity after which a pass-through session is terminated (0 means it never terminates)rw Integer32 .1.3.6.1.4.1.3052.17.2.16.2.1 |
sysPTEndPausenumber of 16ths of a second between escape characters received on pass-through origin IO handle that are reuired for the escape characters to register as pass-through escape characters in the pass-through escape sequence. Set to 0 to make the escape character register as part of the pass- through escape sequence without requiring a pause.rw Integer32 .1.3.6.1.4.1.3052.17.2.16.2.2 |
sysMTUMaximum transfer unit for ethernet interfacesrw Integer32 .1.3.6.1.4.1.3052.17.2.16.3 |
sysAnswerStringString displayed upon loginrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.4 |
sysEventFileIDID string for events filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.6 |
sysEscapeCharacterDecimal ASCII code of the system escape characterrw Integer32 .1.3.6.1.4.1.3052.17.2.16.7 |
sysTimeStamp OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.16.8 |
sysTimeStampTimeFormatFormat of time stamp: HH:MM,HH:MM:SS,BLANKrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.8.1 |
sysTimeStampDateFormatFormat of date stamp: MM/DD,MM/DD/YY,MM/DD/YYYY,BLANKrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.8.2 |
sysTimeStampSpaceAfterON/OFF Inlude a space after timestamprw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.8.3 |
sysLog OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.16.9 |
sysLogModeSyslog mode: disabled, emit UDP (REMOTE), save in a rotating file set (FILE), or emit on a listening socket (SERVER)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.9.1 |
sysLoghostSyslog host: destination machine when syslog mode is REMOTErw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.9.2 |
sysLogFilterString describing what functions place data in the syslogrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.9.3 |
sysLogFileSizeSize (in KB) of syslog files (when syslog mode is SERVER or FILE)rw Integer32 .1.3.6.1.4.1.3052.17.2.16.9.4 |
sysLogFileCountNumber of files in syslog file set (when syslog mode is SERVER or FILE)rw Integer32 .1.3.6.1.4.1.3052.17.2.16.9.5 |
sysLogListenPortTCP port on which the unit listens for a connection on which syslog data is dumped (when syslog mode is SERVER)rw Integer32 .1.3.6.1.4.1.3052.17.2.16.9.6 |
sysCRDB OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.16.10 |
sysCRDBCapacityCapacity of Call Record Database (in KB)ro Integer32 .1.3.6.1.4.1.3052.17.2.16.10.1 |
sysCRDBPercentFullPercent of the CRDB usedro Integer32 .1.3.6.1.4.1.3052.17.2.16.10.2 |
sysCRDBFileIDTableTable of CRDB file IDs SEQUENCE OF CRDBFileIDConfig .1.3.6.1.4.1.3052.17.2.16.10.3 |
sysCRDBFileIDEntryEntry for table of CRDB file IDs CRDBFileIDConfig .1.3.6.1.4.1.3052.17.2.16.10.3.1 |
sysCRDBFileIDIndexIndex for table of CRDB file IDsro Integer32 .1.3.6.1.4.1.3052.17.2.16.10.3.1.1 |
sysCRDBFileIDID of CRDB file for this port-associated file xrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.10.3.1.2 |
sysCRDBFileEnforceMinTableTable of CRDB file minimum size enforcement settings SEQUENCE OF CRDBFileEnforceMinConfig .1.3.6.1.4.1.3052.17.2.16.10.4 |
sysCRDBFileEnforceMinEntryEntry for table of CRDB file minimum size enforcement settings CRDBFileEnforceMinConfig .1.3.6.1.4.1.3052.17.2.16.10.4.1 |
sysCRDBFileEnforceMinIndexIndex for table of CRDB file minimum size enforcement settingsro Integer32 .1.3.6.1.4.1.3052.17.2.16.10.4.1.1 |
sysCRDBFileEnforceMinON/OFF: enforce minimum size for this CRDB file xrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.10.4.1.2 |
sysCharMaskCharacter mask used for ignoring certain characters on serial ports when assembling data records (when port mode is ASCII)rw OCTET STRING .1.3.6.1.4.1.3052.17.2.16.11 |
sysPromptPrompt to use in a commnand sessionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.12 |
sysBootStatusString describing the boot status of the unit (Booted OK/ still bootingro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.13 |
sysLoc OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.16.14 |
sysLocLatitudeLatitude portion of geographic coordinates as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.14.1 |
sysLocLongitudeLongitude portion of geographic coordinates as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.14.2 |
sysLocXOffsetX-offset portion of geographic coordinates as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.14.3 |
sysLocYOffsetY offset portion of geographic coordinates as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.14.4 |
sysLocAngleAngle portion of geographic coordinates as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.14.5 |
sysLocAltitudeAltitude as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.14.6 |
sysFileTransfer OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.16.17 |
sysFileTransferStatusStart/cancel file transfer, or check transfer status. To start, set this object to 'start'. To cancel, set this object to 'cancel'. To check status, get the objectrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.17.1 |
sysFileTransferURLURL (describing protocol, host, directory, and file) on which file transfer function operates.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.17.2 |
sysFileTransferUsernameUsername for user account at the resource specified by sysFileTransferURL.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.17.3 |
sysFileTransferPasswordPassword for user account at the resource specified by sysFileTransferURL.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.17.4 |
sysUpdate OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.16.18 |
sysUpdateStatusCheck time/result of last update attempt.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.16.18.1 |
auditLog OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.17 |
auditLogEnableON/OFF enable audit logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.17.1 |
auditLogStoreResetsON/OFF audit log stores when the unit resetsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.17.2 |
auditLogStoreCommandsON/OFF audit log stores commands entered in a command sessionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.17.3 |
auditLogStoreRelaysON/OFF audit log stores relay activityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.17.4 |
auditLogStoreAlarmActionsON/OFF audit log stores action delivery activityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.17.5 |
auditLogStorePwdFailuresON/OFF audit log stores when user was denied loginrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.17.6 |
auditLogStoreLoginsON/OFF audit log stores when a user was allowed loginrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.17.7 |
auditLogStoreSHSKON/OFF audit log stores serial handshaking status (regardless of serial handshaking event)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.17.8 |
auditLogStorePassthroughON/OFF audit log stores pass-through activityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.17.9 |
auditLogStoreInactivityON/OFF audit log stores when sessions expire due to inactivityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.17.10 |
auditLogStorePollingON/OFF audit log stores CRDB polling activityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.17.11 |
auditLogMaxSizeMaximum size (in KB) of audit logrw Integer32 .1.3.6.1.4.1.3052.17.2.17.12 |
scripting OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.18 |
scrGlobalEnableON/OFF enable scriptingrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.1 |
scrDTRCtrlPortEnableTableTable of DTR control port enables SEQUENCE OF ScriptingDTRCtrlPortEnableConfig .1.3.6.1.4.1.3052.17.2.18.2 |
scrDTRCtrlPortEnableEntryEntry for table of DTR control port enables ScriptingDTRCtrlPortEnableConfig .1.3.6.1.4.1.3052.17.2.18.2.1 |
scrDTRCtrlPortEnableIndexIndex for table of DTR control port enablesro Integer32 .1.3.6.1.4.1.3052.17.2.18.2.1.1 |
scrDTRCtrlPortEnableON/OFF enable DTR control of scripting for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.2.1.2 |
scrTableTable of scripts SEQUENCE OF ScriptingConfig .1.3.6.1.4.1.3052.17.2.18.3 |
scrEntryEntry for table of scripts ScriptingConfig .1.3.6.1.4.1.3052.17.2.18.3.1 |
scrIndexIndex for table of scriptsro Integer32 .1.3.6.1.4.1.3052.17.2.18.3.1.1 |
scrEnableON/OFF enable this scriptrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.3.1.2 |
scrNameName of this scriptrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.3.1.3 |
scrFilenameFilename for this scriptrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.3.1.4 |
scrRunAlwaysON/OFF: this script always runsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.3.1.5 |
scrRunAtStartupON/OFF: this script runs at startuprw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.3.1.6 |
scrRunScheduledON/OFF: this script runs at a certain time of dayrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.3.1.7 |
scrScheduleTimeTime of day (HH:MM) this script is scheduled to runrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.3.1.8 |
scrArgumentsArguments for this scriptrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.3.1.9 |
scrRepeatIntervalHow often this script runs (minutes)rw Integer32 .1.3.6.1.4.1.3052.17.2.18.3.1.10 |
scrVolatileStringTableTable of volatile string settings for use in scripts. SEQUENCE OF ScriptingVolatileString .1.3.6.1.4.1.3052.17.2.18.4 |
scrVolatileStringEntryEntry for table of volatile script string settings ScriptingVolatileString .1.3.6.1.4.1.3052.17.2.18.4.1 |
scrVolatileStringIndexIndex for table of volatile script string settingsro Integer32 .1.3.6.1.4.1.3052.17.2.18.4.1.1 |
scrVolatileStringVolatile string for use in scripts. Use this object to cache frequently-changing string values or string values that do not need to persist through reset. This object corresponds to the scripting.vstring[] setting key branch; use those keys in scripts and you can view or change their values with this object.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.4.1.2 |
scrVolatileIntTableTable of volatile integer settings for use in scripts. SEQUENCE OF ScriptingVolatileInt .1.3.6.1.4.1.3052.17.2.18.5 |
scrVolatileIntEntryEntry for table of volatile script integer settings ScriptingVolatileInt .1.3.6.1.4.1.3052.17.2.18.5.1 |
scrVolatileIntIndexIndex for table of volatile script integer settingsro Integer32 .1.3.6.1.4.1.3052.17.2.18.5.1.1 |
scrVolatileIntVolatile integer for use in scripts. Use this object to cache frequently-changing integer values or integer values that do not need to persist through reset. This object corresponds to the scripting.vint[] setting key branch; use those keys in scripts and you can view or change their values with this object.rw Integer32 .1.3.6.1.4.1.3052.17.2.18.5.1.2 |
scrNonVolatileStringTableTable of non-volatile string settings for use in scripts. SEQUENCE OF ScriptingNonVolatileString .1.3.6.1.4.1.3052.17.2.18.6 |
scrNonVolatileStringEntryEntry for table of non-volatile script string settings ScriptingNonVolatileString .1.3.6.1.4.1.3052.17.2.18.6.1 |
scrNonVolatileStringIndexIndex for table of non-volatile script string settingsro Integer32 .1.3.6.1.4.1.3052.17.2.18.6.1.1 |
scrNonVolatileStringNon-volatile string for use in scripts. Use this object to store values that need to persist through reset. This object corresponds to the scripting.nvstring[] setting key branch; use those keys in scripts and you can view or change their values with this object. Note: to store frequently- changing integers, use the scrVolatileString object, otherwise your scripts may cause unnecessary wear of the non-volatile storage medium on the unit.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.18.6.1.2 |
scrNonVolatileIntTableTable of non-volatile integer settings for use in scripts. SEQUENCE OF ScriptingNonVolatileInt .1.3.6.1.4.1.3052.17.2.18.7 |
scrNonVolatileIntEntryEntry for table of non-volatile script integer settings ScriptingNonVolatileInt .1.3.6.1.4.1.3052.17.2.18.7.1 |
scrNonVolatileIntIndexIndex for table of non-volatile script integer settingsro Integer32 .1.3.6.1.4.1.3052.17.2.18.7.1.1 |
scrNonVolatileIntNon-volatile integer for use in scripts. Use this object to store integer values that need to persist through reset. This object corresponds to the scripting.nvint[] setting key branch; use those keys in scripts and you can view or change their values with this object. Note: to store frequently- changing integers, use the scrVolatileInt object, otherwise your scripts may cause unnecessary wear of the non-volatile storage medium on the unit.rw Integer32 .1.3.6.1.4.1.3052.17.2.18.7.1.2 |
generator OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.19 |
genSet OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.19.1 |
genSetEnableEnable genset functionality; that is, a generator is in use.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.19.1.1 |
genSetRelay OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.19.1.2 |
genSetRelayEsWhich EventSensor has the relay which starts the generator.rw Integer32 .1.3.6.1.4.1.3052.17.2.19.1.2.1 |
genSetRelayPointWhich relay starts the generator.rw Integer32 .1.3.6.1.4.1.3052.17.2.19.1.2.2 |
genSetRelayRunningstateWhich relay state corresponds with the generator starting/running.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.19.1.2.3 |
genSetCC OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.19.1.3 |
genSetCCEnableEnable generator running detection functionality; that is, the associated CC is valid for determining if generator is running.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.19.1.3.1 |
genSetCCEsWhich CC EventSensor has the CC which is connected to the genertor running detection monitor.rw Integer32 .1.3.6.1.4.1.3052.17.2.19.1.3.2 |
genSetCCPointWhich CC is connected to the genertor running detection monitor.rw Integer32 .1.3.6.1.4.1.3052.17.2.19.1.3.3 |
genSetCCRunningStateWhich CC physical state corresponds with the generator running.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.19.1.3.4 |
genRun OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.19.2 |
genRunModeGenerator Exercising function main operating mode; set to INHIBIT to inhibit exercising the generator.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.19.2.1 |
genRunSchedSchedule number(s) which govern(s) when Generator Exercising function runs.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.19.2.2 |
genRunDurationNumber of seconds that generator should run, started when the generator needs to start by SCHEDULE or by being forced to start.rw Integer32 .1.3.6.1.4.1.3052.17.2.19.2.3 |
genRunForceWrite 1 to this to force the generator exercising to start. Always reads as 0.rw Integer32 .1.3.6.1.4.1.3052.17.2.19.2.4 |
genRunReqasmRequire ASM connectivity before starting the generator from a schedule.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.19.2.5 |
genRunStatusStatus of Generator Exercising function.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.19.2.6 |
genRunNonstartEvent OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.19.2.7 |
genRunNonstartEventEnableEnable generator non-start event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.19.2.7.1 |
genRunNonstartEventActionsActions for generator non-start event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.19.2.7.2 |
genRunNonstartEventTrapTrap number for generator non-start event.rw Integer32 .1.3.6.1.4.1.3052.17.2.19.2.7.3 |
genRunNonstartEventClassClass (severity) for generator non-start event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.19.2.7.4 |
calendar OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.2.20 |
schedTableTable of schedules SEQUENCE OF ScheduleConfig .1.3.6.1.4.1.3052.17.2.20.1 |
schedEntryEntry for table of schedules. ScheduleConfig .1.3.6.1.4.1.3052.17.2.20.1.1 |
schedIndexIndex for table of schedules.ro Integer32 .1.3.6.1.4.1.3052.17.2.20.1.1.1 |
schedEnableEnable this schedule.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.2 |
schedStartThis is of the form 'mm/dd/yy hh:mm:ss'. This controls on which date/time the schedule starts.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.3 |
schedRepeatModeControls in which way the schedule should repeat.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.4 |
schedRepeatFreqControls how often the schedule should repeat: every nth day, week, month, or year.rw Integer32 .1.3.6.1.4.1.3052.17.2.20.1.1.5 |
schedRepeatEndModeControls how the repeating schedule should end.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.6 |
schedRepeatEndAfterNumber of times this schedule should be repeated; relevant when the repeat end mode is AFTER.rw Integer32 .1.3.6.1.4.1.3052.17.2.20.1.1.7 |
schedRepeatEndOnDate/time (in the form 'mm/yy/dd hh:mm:ss' or blank string) after which repeating should end, relevant when repeat end mode is ON DATE.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.8 |
schedRepeatWeeklySunRun this schedule on Sunday(s); relevant when repeat mode is weekly.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.9 |
schedRepeatWeeklyMonRun this schedule on Monday(s); relevant when repeat mode is weekly.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.10 |
schedRepeatWeeklyTueRun this schedule on Tuesday(s); relevant when repeat mode is weekly.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.11 |
schedRepeatWeeklyWedRun this schedule on Wednesday(s); relevant when repeat mode is weekly.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.12 |
schedRepeatWeeklyThuRun this schedule on Thursday(s); relevant when repeat mode is weekly.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.13 |
schedRepeatWeeklyFriRun this schedule on Friday(s); relevant when repeat mode is weekly.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.14 |
schedRepeatWeeklySatRun this schedule on Saturday(s); relevant when repeat mode is weekly.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.15 |
schedRepeatMonthlyModeEACH means the schedule runs on specific dates of the month. ON THE means the schedule runs on calculated dates of the month according to which day that month starts.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.16 |
schedRepeatMonthlyDatesComma-separated list of dates of a month on which this schedule should run, relevant when repeat monthly mode is EACH.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.17 |
schedRepeatMonthlyOnTheControls on which day of the month this schedule should run, relevant when repeat monthly mode is ON THE.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.18 |
schedRepeatMonthlyOnDayControls the day of week on which this schedule is run, relevant when repeat monthly mode is ON THErw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.19 |
schedRepeatYearlyJanRun this schedule in January, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.20 |
schedRepeatYearlyFebRun this schedule in February, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.21 |
schedRepeatYearlyMarRun this schedule in March, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.22 |
schedRepeatYearlyAprRun this schedule in April, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.23 |
schedRepeatYearlyMayRun this schedule in May, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.24 |
schedRepeatYearlyJunRun this schedule in June, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.25 |
schedRepeatYearlyJulRun this schedule in July, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.26 |
schedRepeatYearlyAugRun this schedule in August, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.27 |
schedRepeatYearlySepRun this schedule in September, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.28 |
schedRepeatYearlyOctRun this schedule in October, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.29 |
schedRepeatYearlyNovRun this schedule in November, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.30 |
schedRepeatYearlyDecRun this schedule in December, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.31 |
schedRepeatYearlyOnTheControls on which day of the month this schedule should run, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.32 |
schedRepeatYearlyOnDayControls the day of week on which this schedule is run, relevant when repeat mode is YEARLY.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.33 |
schedNextTriggerWhen this schedule will next trigger.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.2.20.1.1.34 |
productIds OBJECT IDENTIFIER .1.3.6.1.4.1.3052.17.3 |
siteNameSite Name string; Max 40 characters.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.3.1 |
thisProductThis is a factory configured string for the product name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.3.2 |
stockTrapStringThe message defined for the event that triggers a trap.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.3.3 |
trapEventTypeNumberThe user-defined trap variable for the type of event that happened. Here are the definitions: 4 SCHEDULED 7 Serial Handshaking Low 8 Serial Handshaking High 10 Contact Closure Active 11 Contact Closure Inactive 12 Temperature High 13 Temperature Very High 14 Temperature Low 15 Temperature Very Low 16 Temperature Return to Normal 17 Humidity High 18 Humidity Very High 19 Humidity Low 20 Humidity Very Low 21 Humidity Return to Normal 26 Analog High 27 Analog Very High 28 Analog Low 29 Analog Very Low 30 Analog Normal 40 EventSensor Unresponsive 100 Contact Closure Active Reminder 101 Temperature High Reminder 102 Temperature High Very Reminder 103 Temperature Low Reminder 104 Temperature Very Low Reminder 105 Humidity High Reminder 106 Humidity Very High Reminder 107 Humidity Low Reminder 108 Humidity Very Low Reminder 109 Analog High Reminder 110 Analog Very High Reminder 111 Analog Low Reminder 112 Analog Very Low Reminderro Integer32 .1.3.6.1.4.1.3052.17.3.4 |
trapEventTypeNameThe user-defined trap variable for the string corresponding to the event type.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.3.5 |
trapIncludedValueThe user-defined trap variable for the generic included value.ro Integer32 (-2147483648..2147483647) .1.3.6.1.4.1.3052.17.3.6 |
trapIncludedStringThe user-defined trap variable for the generic included string.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.3.7 |
trapTypeStringThe cause of the trap, added for DL880 compatibility.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.3.8 |
trapEventClassNumberThe user-defined trap variable for the configurable class number associated with the triggering event.ro Integer32 .1.3.6.1.4.1.3052.17.3.9 |
trapEventClassNameThe user-defined trap variable for the configurable class name associated with the class number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.3.10 |
keyInterfaceThis object represents a setting key interface. When setting this object, the value to set is the 'sk' command you would enter on the command line (without the 'sk'). To get the result of the operation, read this object after you write it. For example, to configure EventSensor 1 contact closure 34 event actions to be an SNMP InformRequest to host foo, set this object to: 'event.sensor[1].cc[34].eventactions=inform(foo)'. The SNMP response is the result of the operation: if setting that key to that value was a success then the SNMP response will be a success and the response value will be what you had set. If you subsequently read this object then you will see a message 'OK: ...'. If setting that key to that value failed then the SNMP response will be a failure (a badValue response). If you subsequently read this object then the value returned is the reason that setting that key to that value failed. For another example, to read user 3's pass-through access for port 7, set this object to: 'sec.user[3].port[7].ptaccess'. The SNMP response is the result of the operation: if reading that key is a success then the SNMP response will be a success and the response value will be what you had SET (i.e., the opertion of reading a key, which is just the key itself with no '=' operator, and this is not the key value you want to read). If you subsequently read this object then the value returned is the value of the key you want to read. If reading that key failed (e.g., if the key is invalid) then the SNMP response to your SNMP set operation (the value you set being the invalid key to read) will be a failure (a badValue response). If you subsequently read this object then the value returned is the reason that reading that key failed (i.e., 'invalid key').rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.17.4 |