MIB module for managing Asentria SiteBoss 572
Main OID:
s572.1.3.6.1.4.1.3052.20
1500
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
1500 total| Object Name |
|---|
s572MIB module for managing Asentria SiteBoss 572 MODULE-IDENTITY .1.3.6.1.4.1.3052.20 |
s572Notifications OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.0 |
s572StockContactClosureTrapA stock contact closure trap is issued when a contact closure event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.110 |
s572StockTempTrapA stock temperature trap is issued when a temperature event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.120 |
s572StockHumidityTrapA stock humidity trap is issued when a humidity event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.130 |
s572StockAnalogTrapA stock analog trap is issued when an analog sensor event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.140 |
s572StockOutputTrapA stock output trap is issued when an output event happens. That is, depending on the configuration, when an output changes state for any reason, this trap will be sent. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.150 |
s572StockPDCurrentTrapA stock analog trap is issued when a power distribution current event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.180 |
s572StockPDVoltageTrapA stock analog trap is issued when a power distribution voltage event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.190 |
s572StockPDFuseTrapA stock analog trap is issued when a power distribution fuse event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.210 |
s572StockDataAlarmTrapThe stock data alarm trap is issued when a data alarm happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.503 |
s572StockNoDataAlarmTrapThe stock no-data alarm trap is issued when the unit has received no data for a configured interval within a configured schedule. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.505 |
s572StockSchedTrapThe stock scheduled alarm trap is issued when the current time reaches the scheduled alarm time. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.506 |
s572StockImmediateTrapThe stock immediate alarm trap is issued when the user enters the DOTRAP command. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.507 |
s572StockCTSTrapA stock CTS trap is issued when an RS-232 CTS event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.510 |
s572CPEDownTrapA stock CPE Down trap is issued when a CPE Down event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.511 |
s572FuelSensorDisconnectTrapA stock Fuel Sensor Disconnect trap is issued when a Fuel Sensor Disconnect or Connect (Return to Normal) event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.515 |
s572FuelSensorVolumeTrapA stock Fuel Sensor Volume trap is issued when a Fuel Sensor Volume event happens NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.519 |
s572ACPowerMonitorAvgVoltageTrapA stock AC power monitor average voltage trap is issued when an AC power monitor average voltage event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.520 |
s572ACPowerMonitorAvgCurrentTrapA stock AC power monitor average current trap is issued when an AC power monitor average current event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.521 |
s572ACPowerMonitorFrequencyTrapA stock AC power monitor frequency trap is issued when an AC power monitor frequency event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.522 |
s572ACPowerMonitorTRPTrapA stock AC power monitor TRP (total real power) trap is issued when an AC power monitor TRP event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.523 |
s572ACPowerMonitorDisconnectTrapA stock AC power monitor disconnect trap is issued when an AC power monitor disconnect event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.524 |
s572StockLoadSheddingTrapA stock Load Shedding trap is issued when a Load Shedding event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.525 |
s572StockScriptTrapA stock script trap is issued when a script triggers an event via a_lib.PostEvent() called with no trap number (or this trap number) specified. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.526 |
s572FuelSensorVolumeSuddenChangeTrapA stock Fuel Sensor Volume Sudden Change trap is issued when a Fuel Sensor Volume Sudden Change event happens NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.527 |
s572FuelSensorVolumeSlowChangeTrapA stock Fuel Sensor Volume Slow Change trap is issued when a Fuel Sensor Volume Slow Change event happens NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.528 |
s572ACTotalPowerFactorTrapA stock AC power monitor total power factor trap is issued when an AC power monitor total power factor event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.540 |
s572ResetTrapA stock reset trap is issued when a reset event happens. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.543 |
s572UserTrap1000This user-defined trap is issued when an event happens that causes a trap with specific trap type 1000. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1000 |
s572UserTrap1001This user-defined trap is issued when an event happens that causes a trap with specific trap type 1001. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1001 |
s572UserTrap1002This user-defined trap is issued when an event happens that causes a trap with specific trap type 1002. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1002 |
s572UserTrap1003This user-defined trap is issued when an event happens that causes a trap with specific trap type 1003. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1003 |
s572UserTrap1004This user-defined trap is issued when an event happens that causes a trap with specific trap type 1004. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1004 |
s572UserTrap1005This user-defined trap is issued when an event happens that causes a trap with specific trap type 1005. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1005 |
s572UserTrap1006This user-defined trap is issued when an event happens that causes a trap with specific trap type 1006. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1006 |
s572UserTrap1007This user-defined trap is issued when an event happens that causes a trap with specific trap type 1007. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1007 |
s572UserTrap1008This user-defined trap is issued when an event happens that causes a trap with specific trap type 1008. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1008 |
s572UserTrap1009This user-defined trap is issued when an event happens that causes a trap with specific trap type 1009. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1009 |
s572UserTrap1010This user-defined trap is issued when an event happens that causes a trap with specific trap type 1010. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1010 |
s572UserTrap1011This user-defined trap is issued when an event happens that causes a trap with specific trap type 1011. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1011 |
s572UserTrap1012This user-defined trap is issued when an event happens that causes a trap with specific trap type 1012. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1012 |
s572UserTrap1013This user-defined trap is issued when an event happens that causes a trap with specific trap type 1013. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1013 |
s572UserTrap1014This user-defined trap is issued when an event happens that causes a trap with specific trap type 1014. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1014 |
s572UserTrap1015This user-defined trap is issued when an event happens that causes a trap with specific trap type 1015. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1015 |
s572UserTrap1016This user-defined trap is issued when an event happens that causes a trap with specific trap type 1016. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1016 |
s572UserTrap1017This user-defined trap is issued when an event happens that causes a trap with specific trap type 1017. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1017 |
s572UserTrap1018This user-defined trap is issued when an event happens that causes a trap with specific trap type 1018. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1018 |
s572UserTrap1019This user-defined trap is issued when an event happens that causes a trap with specific trap type 1019. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1019 |
s572UserTrap1020This user-defined trap is issued when an event happens that causes a trap with specific trap type 1020. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1020 |
s572UserTrap1021This user-defined trap is issued when an event happens that causes a trap with specific trap type 1021. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1021 |
s572UserTrap1022This user-defined trap is issued when an event happens that causes a trap with specific trap type 1022. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1022 |
s572UserTrap1023This user-defined trap is issued when an event happens that causes a trap with specific trap type 1023. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1023 |
s572UserTrap1024This user-defined trap is issued when an event happens that causes a trap with specific trap type 1024. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1024 |
s572UserTrap1025This user-defined trap is issued when an event happens that causes a trap with specific trap type 1025. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1025 |
s572UserTrap1026This user-defined trap is issued when an event happens that causes a trap with specific trap type 1026. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1026 |
s572UserTrap1027This user-defined trap is issued when an event happens that causes a trap with specific trap type 1027. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1027 |
s572UserTrap1028This user-defined trap is issued when an event happens that causes a trap with specific trap type 1028. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1028 |
s572UserTrap1029This user-defined trap is issued when an event happens that causes a trap with specific trap type 1029. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1029 |
s572UserTrap1030This user-defined trap is issued when an event happens that causes a trap with specific trap type 1030. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1030 |
s572UserTrap1031This user-defined trap is issued when an event happens that causes a trap with specific trap type 1031. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1031 |
s572UserTrap1032This user-defined trap is issued when an event happens that causes a trap with specific trap type 1032. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1032 |
s572UserTrap1033This user-defined trap is issued when an event happens that causes a trap with specific trap type 1033. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1033 |
s572UserTrap1034This user-defined trap is issued when an event happens that causes a trap with specific trap type 1034. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1034 |
s572UserTrap1035This user-defined trap is issued when an event happens that causes a trap with specific trap type 1035. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1035 |
s572UserTrap1036This user-defined trap is issued when an event happens that causes a trap with specific trap type 1036. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1036 |
s572UserTrap1037This user-defined trap is issued when an event happens that causes a trap with specific trap type 1037. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1037 |
s572UserTrap1038This user-defined trap is issued when an event happens that causes a trap with specific trap type 1038. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1038 |
s572UserTrap1039This user-defined trap is issued when an event happens that causes a trap with specific trap type 1039. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1039 |
s572UserTrap1040This user-defined trap is issued when an event happens that causes a trap with specific trap type 1040. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1040 |
s572UserTrap1041This user-defined trap is issued when an event happens that causes a trap with specific trap type 1041. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1041 |
s572UserTrap1042This user-defined trap is issued when an event happens that causes a trap with specific trap type 1042. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1042 |
s572UserTrap1043This user-defined trap is issued when an event happens that causes a trap with specific trap type 1043. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1043 |
s572UserTrap1044This user-defined trap is issued when an event happens that causes a trap with specific trap type 1044. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1044 |
s572UserTrap1045This user-defined trap is issued when an event happens that causes a trap with specific trap type 1045. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1045 |
s572UserTrap1046This user-defined trap is issued when an event happens that causes a trap with specific trap type 1046. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1046 |
s572UserTrap1047This user-defined trap is issued when an event happens that causes a trap with specific trap type 1047. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1047 |
s572UserTrap1048This user-defined trap is issued when an event happens that causes a trap with specific trap type 1048. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1048 |
s572UserTrap1049This user-defined trap is issued when an event happens that causes a trap with specific trap type 1049. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1049 |
s572UserTrap1050This user-defined trap is issued when an event happens that causes a trap with specific trap type 1050. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1050 |
s572UserTrap1051This user-defined trap is issued when an event happens that causes a trap with specific trap type 1051. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1051 |
s572UserTrap1052This user-defined trap is issued when an event happens that causes a trap with specific trap type 1052. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1052 |
s572UserTrap1053This user-defined trap is issued when an event happens that causes a trap with specific trap type 1053. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1053 |
s572UserTrap1054This user-defined trap is issued when an event happens that causes a trap with specific trap type 1054. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1054 |
s572UserTrap1055This user-defined trap is issued when an event happens that causes a trap with specific trap type 1055. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1055 |
s572UserTrap1056This user-defined trap is issued when an event happens that causes a trap with specific trap type 1056. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1056 |
s572UserTrap1057This user-defined trap is issued when an event happens that causes a trap with specific trap type 1057. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1057 |
s572UserTrap1058This user-defined trap is issued when an event happens that causes a trap with specific trap type 1058. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1058 |
s572UserTrap1059This user-defined trap is issued when an event happens that causes a trap with specific trap type 1059. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1059 |
s572UserTrap1060This user-defined trap is issued when an event happens that causes a trap with specific trap type 1060. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1060 |
s572UserTrap1061This user-defined trap is issued when an event happens that causes a trap with specific trap type 1061. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1061 |
s572UserTrap1062This user-defined trap is issued when an event happens that causes a trap with specific trap type 1062. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1062 |
s572UserTrap1063This user-defined trap is issued when an event happens that causes a trap with specific trap type 1063. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1063 |
s572UserTrap1064This user-defined trap is issued when an event happens that causes a trap with specific trap type 1064. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1064 |
s572UserTrap1065This user-defined trap is issued when an event happens that causes a trap with specific trap type 1065. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1065 |
s572UserTrap1066This user-defined trap is issued when an event happens that causes a trap with specific trap type 1066. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1066 |
s572UserTrap1067This user-defined trap is issued when an event happens that causes a trap with specific trap type 1067. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1067 |
s572UserTrap1068This user-defined trap is issued when an event happens that causes a trap with specific trap type 1068. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1068 |
s572UserTrap1069This user-defined trap is issued when an event happens that causes a trap with specific trap type 1069. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1069 |
s572UserTrap1070This user-defined trap is issued when an event happens that causes a trap with specific trap type 1070. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1070 |
s572UserTrap1071This user-defined trap is issued when an event happens that causes a trap with specific trap type 1071. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1071 |
s572UserTrap1072This user-defined trap is issued when an event happens that causes a trap with specific trap type 1072. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1072 |
s572UserTrap1073This user-defined trap is issued when an event happens that causes a trap with specific trap type 1073. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1073 |
s572UserTrap1074This user-defined trap is issued when an event happens that causes a trap with specific trap type 1074. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1074 |
s572UserTrap1075This user-defined trap is issued when an event happens that causes a trap with specific trap type 1075. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1075 |
s572UserTrap1076This user-defined trap is issued when an event happens that causes a trap with specific trap type 1076. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1076 |
s572UserTrap1077This user-defined trap is issued when an event happens that causes a trap with specific trap type 1077. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1077 |
s572UserTrap1078This user-defined trap is issued when an event happens that causes a trap with specific trap type 1078. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1078 |
s572UserTrap1079This user-defined trap is issued when an event happens that causes a trap with specific trap type 1079. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1079 |
s572UserTrap1080This user-defined trap is issued when an event happens that causes a trap with specific trap type 1080. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1080 |
s572UserTrap1081This user-defined trap is issued when an event happens that causes a trap with specific trap type 1081. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1081 |
s572UserTrap1082This user-defined trap is issued when an event happens that causes a trap with specific trap type 1082. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1082 |
s572UserTrap1083This user-defined trap is issued when an event happens that causes a trap with specific trap type 1083. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1083 |
s572UserTrap1084This user-defined trap is issued when an event happens that causes a trap with specific trap type 1084. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1084 |
s572UserTrap1085This user-defined trap is issued when an event happens that causes a trap with specific trap type 1085. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1085 |
s572UserTrap1086This user-defined trap is issued when an event happens that causes a trap with specific trap type 1086. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1086 |
s572UserTrap1087This user-defined trap is issued when an event happens that causes a trap with specific trap type 1087. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1087 |
s572UserTrap1088This user-defined trap is issued when an event happens that causes a trap with specific trap type 1088. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1088 |
s572UserTrap1089This user-defined trap is issued when an event happens that causes a trap with specific trap type 1089. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1089 |
s572UserTrap1090This user-defined trap is issued when an event happens that causes a trap with specific trap type 1090. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1090 |
s572UserTrap1091This user-defined trap is issued when an event happens that causes a trap with specific trap type 1091. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1091 |
s572UserTrap1092This user-defined trap is issued when an event happens that causes a trap with specific trap type 1092. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1092 |
s572UserTrap1093This user-defined trap is issued when an event happens that causes a trap with specific trap type 1093. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1093 |
s572UserTrap1094This user-defined trap is issued when an event happens that causes a trap with specific trap type 1094. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1094 |
s572UserTrap1095This user-defined trap is issued when an event happens that causes a trap with specific trap type 1095. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1095 |
s572UserTrap1096This user-defined trap is issued when an event happens that causes a trap with specific trap type 1096. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1096 |
s572UserTrap1097This user-defined trap is issued when an event happens that causes a trap with specific trap type 1097. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1097 |
s572UserTrap1098This user-defined trap is issued when an event happens that causes a trap with specific trap type 1098. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1098 |
s572UserTrap1099This user-defined trap is issued when an event happens that causes a trap with specific trap type 1099. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1099 |
s572UserTrap1100This user-defined trap is issued when an event happens that causes a trap with specific trap type 1100. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1100 |
s572UserTrap1101This user-defined trap is issued when an event happens that causes a trap with specific trap type 1101. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1101 |
s572UserTrap1102This user-defined trap is issued when an event happens that causes a trap with specific trap type 1102. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1102 |
s572UserTrap1103This user-defined trap is issued when an event happens that causes a trap with specific trap type 1103. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1103 |
s572UserTrap1104This user-defined trap is issued when an event happens that causes a trap with specific trap type 1104. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1104 |
s572UserTrap1105This user-defined trap is issued when an event happens that causes a trap with specific trap type 1105. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1105 |
s572UserTrap1106This user-defined trap is issued when an event happens that causes a trap with specific trap type 1106. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1106 |
s572UserTrap1107This user-defined trap is issued when an event happens that causes a trap with specific trap type 1107. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1107 |
s572UserTrap1108This user-defined trap is issued when an event happens that causes a trap with specific trap type 1108. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1108 |
s572UserTrap1109This user-defined trap is issued when an event happens that causes a trap with specific trap type 1109. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1109 |
s572UserTrap1110This user-defined trap is issued when an event happens that causes a trap with specific trap type 1110. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1110 |
s572UserTrap1111This user-defined trap is issued when an event happens that causes a trap with specific trap type 1111. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1111 |
s572UserTrap1112This user-defined trap is issued when an event happens that causes a trap with specific trap type 1112. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1112 |
s572UserTrap1113This user-defined trap is issued when an event happens that causes a trap with specific trap type 1113. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1113 |
s572UserTrap1114This user-defined trap is issued when an event happens that causes a trap with specific trap type 1114. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1114 |
s572UserTrap1115This user-defined trap is issued when an event happens that causes a trap with specific trap type 1115. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1115 |
s572UserTrap1116This user-defined trap is issued when an event happens that causes a trap with specific trap type 1116. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1116 |
s572UserTrap1117This user-defined trap is issued when an event happens that causes a trap with specific trap type 1117. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1117 |
s572UserTrap1118This user-defined trap is issued when an event happens that causes a trap with specific trap type 1118. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1118 |
s572UserTrap1119This user-defined trap is issued when an event happens that causes a trap with specific trap type 1119. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1119 |
s572UserTrap1120This user-defined trap is issued when an event happens that causes a trap with specific trap type 1120. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1120 |
s572UserTrap1121This user-defined trap is issued when an event happens that causes a trap with specific trap type 1121. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1121 |
s572UserTrap1122This user-defined trap is issued when an event happens that causes a trap with specific trap type 1122. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1122 |
s572UserTrap1123This user-defined trap is issued when an event happens that causes a trap with specific trap type 1123. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1123 |
s572UserTrap1124This user-defined trap is issued when an event happens that causes a trap with specific trap type 1124. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1124 |
s572UserTrap1125This user-defined trap is issued when an event happens that causes a trap with specific trap type 1125. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1125 |
s572UserTrap1126This user-defined trap is issued when an event happens that causes a trap with specific trap type 1126. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1126 |
s572UserTrap1127This user-defined trap is issued when an event happens that causes a trap with specific trap type 1127. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1127 |
s572UserTrap1128This user-defined trap is issued when an event happens that causes a trap with specific trap type 1128. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1128 |
s572UserTrap1129This user-defined trap is issued when an event happens that causes a trap with specific trap type 1129. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1129 |
s572UserTrap1130This user-defined trap is issued when an event happens that causes a trap with specific trap type 1130. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1130 |
s572UserTrap1131This user-defined trap is issued when an event happens that causes a trap with specific trap type 1131. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1131 |
s572UserTrap1132This user-defined trap is issued when an event happens that causes a trap with specific trap type 1132. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1132 |
s572UserTrap1133This user-defined trap is issued when an event happens that causes a trap with specific trap type 1133. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1133 |
s572UserTrap1134This user-defined trap is issued when an event happens that causes a trap with specific trap type 1134. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1134 |
s572UserTrap1135This user-defined trap is issued when an event happens that causes a trap with specific trap type 1135. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1135 |
s572UserTrap1136This user-defined trap is issued when an event happens that causes a trap with specific trap type 1136. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1136 |
s572UserTrap1137This user-defined trap is issued when an event happens that causes a trap with specific trap type 1137. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1137 |
s572UserTrap1138This user-defined trap is issued when an event happens that causes a trap with specific trap type 1138. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1138 |
s572UserTrap1139This user-defined trap is issued when an event happens that causes a trap with specific trap type 1139. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1139 |
s572UserTrap1140This user-defined trap is issued when an event happens that causes a trap with specific trap type 1140. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1140 |
s572UserTrap1141This user-defined trap is issued when an event happens that causes a trap with specific trap type 1141. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1141 |
s572UserTrap1142This user-defined trap is issued when an event happens that causes a trap with specific trap type 1142. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1142 |
s572UserTrap1143This user-defined trap is issued when an event happens that causes a trap with specific trap type 1143. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1143 |
s572UserTrap1144This user-defined trap is issued when an event happens that causes a trap with specific trap type 1144. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1144 |
s572UserTrap1145This user-defined trap is issued when an event happens that causes a trap with specific trap type 1145. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1145 |
s572UserTrap1146This user-defined trap is issued when an event happens that causes a trap with specific trap type 1146. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1146 |
s572UserTrap1147This user-defined trap is issued when an event happens that causes a trap with specific trap type 1147. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1147 |
s572UserTrap1148This user-defined trap is issued when an event happens that causes a trap with specific trap type 1148. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1148 |
s572UserTrap1149This user-defined trap is issued when an event happens that causes a trap with specific trap type 1149. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1149 |
s572UserTrap1150This user-defined trap is issued when an event happens that causes a trap with specific trap type 1150. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1150 |
s572UserTrap1151This user-defined trap is issued when an event happens that causes a trap with specific trap type 1151. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1151 |
s572UserTrap1152This user-defined trap is issued when an event happens that causes a trap with specific trap type 1152. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1152 |
s572UserTrap1153This user-defined trap is issued when an event happens that causes a trap with specific trap type 1153. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1153 |
s572UserTrap1154This user-defined trap is issued when an event happens that causes a trap with specific trap type 1154. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1154 |
s572UserTrap1155This user-defined trap is issued when an event happens that causes a trap with specific trap type 1155. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1155 |
s572UserTrap1156This user-defined trap is issued when an event happens that causes a trap with specific trap type 1156. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1156 |
s572UserTrap1157This user-defined trap is issued when an event happens that causes a trap with specific trap type 1157. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1157 |
s572UserTrap1158This user-defined trap is issued when an event happens that causes a trap with specific trap type 1158. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1158 |
s572UserTrap1159This user-defined trap is issued when an event happens that causes a trap with specific trap type 1159. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1159 |
s572UserTrap1160This user-defined trap is issued when an event happens that causes a trap with specific trap type 1160. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1160 |
s572UserTrap1161This user-defined trap is issued when an event happens that causes a trap with specific trap type 1161. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1161 |
s572UserTrap1162This user-defined trap is issued when an event happens that causes a trap with specific trap type 1162. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1162 |
s572UserTrap1163This user-defined trap is issued when an event happens that causes a trap with specific trap type 1163. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1163 |
s572UserTrap1164This user-defined trap is issued when an event happens that causes a trap with specific trap type 1164. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1164 |
s572UserTrap1165This user-defined trap is issued when an event happens that causes a trap with specific trap type 1165. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1165 |
s572UserTrap1166This user-defined trap is issued when an event happens that causes a trap with specific trap type 1166. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1166 |
s572UserTrap1167This user-defined trap is issued when an event happens that causes a trap with specific trap type 1167. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1167 |
s572UserTrap1168This user-defined trap is issued when an event happens that causes a trap with specific trap type 1168. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1168 |
s572UserTrap1169This user-defined trap is issued when an event happens that causes a trap with specific trap type 1169. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1169 |
s572UserTrap1170This user-defined trap is issued when an event happens that causes a trap with specific trap type 1170. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1170 |
s572UserTrap1171This user-defined trap is issued when an event happens that causes a trap with specific trap type 1171. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1171 |
s572UserTrap1172This user-defined trap is issued when an event happens that causes a trap with specific trap type 1172. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1172 |
s572UserTrap1173This user-defined trap is issued when an event happens that causes a trap with specific trap type 1173. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1173 |
s572UserTrap1174This user-defined trap is issued when an event happens that causes a trap with specific trap type 1174. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1174 |
s572UserTrap1175This user-defined trap is issued when an event happens that causes a trap with specific trap type 1175. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1175 |
s572UserTrap1176This user-defined trap is issued when an event happens that causes a trap with specific trap type 1176. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1176 |
s572UserTrap1177This user-defined trap is issued when an event happens that causes a trap with specific trap type 1177. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1177 |
s572UserTrap1178This user-defined trap is issued when an event happens that causes a trap with specific trap type 1178. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1178 |
s572UserTrap1179This user-defined trap is issued when an event happens that causes a trap with specific trap type 1179. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1179 |
s572UserTrap1180This user-defined trap is issued when an event happens that causes a trap with specific trap type 1180. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1180 |
s572UserTrap1181This user-defined trap is issued when an event happens that causes a trap with specific trap type 1181. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1181 |
s572UserTrap1182This user-defined trap is issued when an event happens that causes a trap with specific trap type 1182. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1182 |
s572UserTrap1183This user-defined trap is issued when an event happens that causes a trap with specific trap type 1183. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1183 |
s572UserTrap1184This user-defined trap is issued when an event happens that causes a trap with specific trap type 1184. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1184 |
s572UserTrap1185This user-defined trap is issued when an event happens that causes a trap with specific trap type 1185. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1185 |
s572UserTrap1186This user-defined trap is issued when an event happens that causes a trap with specific trap type 1186. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1186 |
s572UserTrap1187This user-defined trap is issued when an event happens that causes a trap with specific trap type 1187. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1187 |
s572UserTrap1188This user-defined trap is issued when an event happens that causes a trap with specific trap type 1188. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1188 |
s572UserTrap1189This user-defined trap is issued when an event happens that causes a trap with specific trap type 1189. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1189 |
s572UserTrap1190This user-defined trap is issued when an event happens that causes a trap with specific trap type 1190. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1190 |
s572UserTrap1191This user-defined trap is issued when an event happens that causes a trap with specific trap type 1191. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1191 |
s572UserTrap1192This user-defined trap is issued when an event happens that causes a trap with specific trap type 1192. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1192 |
s572UserTrap1193This user-defined trap is issued when an event happens that causes a trap with specific trap type 1193. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1193 |
s572UserTrap1194This user-defined trap is issued when an event happens that causes a trap with specific trap type 1194. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1194 |
s572UserTrap1195This user-defined trap is issued when an event happens that causes a trap with specific trap type 1195. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1195 |
s572UserTrap1196This user-defined trap is issued when an event happens that causes a trap with specific trap type 1196. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1196 |
s572UserTrap1197This user-defined trap is issued when an event happens that causes a trap with specific trap type 1197. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1197 |
s572UserTrap1198This user-defined trap is issued when an event happens that causes a trap with specific trap type 1198. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1198 |
s572UserTrap1199This user-defined trap is issued when an event happens that causes a trap with specific trap type 1199. NOTIFICATION-TYPE .1.3.6.1.4.1.3052.20.0.1199 |
status OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.1 |
eventSensorStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.1.1 |
esPointTableThis table organizes 4 basic attributes of points. A point is a particular sensor on an EventSensor (e.g., temperature, humidity, contact closure 2, output 5, etc.). The 4 point attributes are its name, whether it's in its event state, the point's value as a number and its value as a string. Points are referenced by a point index. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). SEQUENCE OF ESPoint .1.3.6.1.4.1.3052.20.1.1.1 |
esPointEntryEntry for EventSensor point table ESPoint .1.3.6.1.4.1.3052.20.1.1.1.1 |
esIndexESThe part of the point index that refers to an EventSensor. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndexES=2 will now refer to that particular EventSensor.ro Integer32 .1.3.6.1.4.1.3052.20.1.1.1.1.1 |
esIndexPCThe part of the point index that refers to point class. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). The values for this object are: 1=temperature sensor 2=contact closure 3=humidity sensor 4=noise sensor 5=analog input 6=output (relay output or power output)ro Integer32 .1.3.6.1.4.1.3052.20.1.1.1.1.2 |
esIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with esIndexPC (Point Class or type) and esIndexES (which EventSensor) uniquely defines each point (sensor or output) attached to a unit. For example, if esIndexES is 3, esIndexPC is 1 and esIndexPoint is 4 then this is the Fourth Temperature Sensor on EventSensor number 3.ro Integer32 .1.3.6.1.4.1.3052.20.1.1.1.1.3 |
esPointNameThe name of the point on an EventSensor. For example, 'AC temp' (in the case of the temperature sensor on an EventSensor). There can be multiple points of the same point class on an EventSensor (e.g., 8 contact closures) and multiple sensor classes on an EventSensor (e.g., temperature, contact closure, humidity). If the point referenced by a given point index is solitary (e.g., temperature sensor, because there can be only one on an EventSensor), then this object reads as '<EventSensor name>'. Setting this object for solitary point indices sets the EventSensor name only. On the other hand, if a given point is among other points of the same point class on an EventSensor, then this object reads as '<Sensor name>'. Setting this object for these NON- solitary point indices sets the sensor name only - not the EventSensor name.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.1.1.1.4 |
esPointInEventStateA number referring to the event state of a point on an EventSensor. This number can have different meanings depending on the point class. If the point class is temperature, humidity, or analog input, then the values of this object are: 1=very low 2=low 3=normal 4=high 5=very high For contact closures the values of this object are: 1=point in event state 2=point in normal state For outputs the values of this object is the numeric code for the logical state of the output: 1 or 2. The logical state of the output is either active/inactive for relay outputs or on/off for power outputs. The logical state of the output has different nomenclature depending on the type of the output (relay output or power output): 1=active (for relay output) or on (for power output) 2=inactive (for relay output) or off (for power output) This is not necessarily representative of physical state of the output. Physical state is energized/de-energized, for both relay and power outputs. For relay outputs, the active logical state corresponds to either the energized physical state or the de-energized physical state depending on how the relay output is configured. For power outputs, the on logical state always corresponds to the energized physical state. For any point class and any point, if the event state is undefined, then the value of this object is 0. For any point class except output, this object is read-only. For outputs, setting this object to 1 puts the output into its active logical state. Setting this object to 2 puts the output into its inactive logical state. Setting this object to any value greater than 2 puts the output into its active logical state for that many seconds (up to 3600), after which time it puts the output into its inactive logical state.rw Integer32 .1.3.6.1.4.1.3052.20.1.1.1.1.5 |
esPointValueIntA read-only number referring to the value of a point on an EventSensor. If the point class is temperature, then this object is the temperature in its configured scale (default is Fahrenheit). If the point class is contact closure, then this object is either 0 (open) or 1 (closed). If the point class is humidity, then this object is the percent relative humidity. If the point class is analog input, then this object is the signed input value in tenths of the configured units. If the point class is an output, then this object is the numeric code for the physical state of the output. 0=de-energized 1=energized This object cannot be used to control the output, i.e, change its logical or physical state (instead use the esPointInEventState object).rw Integer32 (-2147483648..2147483647) .1.3.6.1.4.1.3052.20.1.1.1.1.6 |
esPointValueStrA string referring to the value of a point on an EventSensor. For contact closures this object is either 'Open' or 'Closed'. For outputs this object is a concatenation of the logical state and physical state, separated by '/'. For a relay output this object can be one of the following 4 possible values: Active/Energized Inactive/Energized Active/De-energized Inactve/De-energized For a power output this object can be one of the following 2 possible values: On/Energized Off/De-energized For temperature and humidity point classes, this object is the string representation of the esPointValueInt object. For temperature, 'C' or 'F' is including in the string to indicate scale. For analog inputs, this object is the string representation of the plus/minus input in the configured units appended with the unit name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.1.1.1.7 |
esPointTimeLastChangeThe time of the last time an event was triggerred for a point on an EventSensor in MM/DD/YY HH:MM:SS format. For contact closures, the possible events are Active and Inactive. For temperature, humidity, and analog inputs, the possible events are Normal, High, Very High, Low, and Very Low. For outputs, this object is a null string.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.1.1.1.8 |
esPointTimetickLastChangeThe time of the last time an event was triggerred for a point on an EventSensor in 100ths of seconds since reset. For contact closures, the possible events are Active and Inactive. For temperature, humidity, and analog inputs, the possible events are Normal, High, Very High, Low, and Very Low. For outputs, this object is 0.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.3052.20.1.1.1.1.9 |
dataEventStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.1.2 |
deStatusTableData Event Status Table SEQUENCE OF DEStatus .1.3.6.1.4.1.3052.20.1.2.1 |
deStatusEntryEventSensor status entry DEStatus .1.3.6.1.4.1.3052.20.1.2.1.1 |
deStatusIndexIndex for Data Eventsro Integer32 .1.3.6.1.4.1.3052.20.1.2.1.1.1 |
deStatusNameData Event namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.2.1.1.2 |
deStatusCounterNumber of times a data record has matched this event's equation. Range: 1-999999999ro Integer32 .1.3.6.1.4.1.3052.20.1.2.1.1.3 |
deStatusThresholdNumber of times the equation is matched before an event is triggered. Range: 1-999999999ro Integer32 .1.3.6.1.4.1.3052.20.1.2.1.1.4 |
modemStatusstatus of modem (idle, dialing, connected, etc.)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.3 |
modemCLIDLogTableTable of numbers of recent dialing parties SEQUENCE OF ModemCLIDLogConfig .1.3.6.1.4.1.3052.20.1.4 |
modemCLIDLogEntryEntry for table of CLID log entries ModemCLIDLogConfig .1.3.6.1.4.1.3052.20.1.4.1 |
modemCLIDLogIndexIndex for table of CLID log entriesro Integer32 .1.3.6.1.4.1.3052.20.1.4.1.1 |
modemCLIDLogNumberrecently logged number of dialing partyrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.4.1.2 |
powerDistributionStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.1.5 |
pdConfigPower Distribution output configurationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.1 |
pdNextGen OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.1.5.4 |
pdnTableTable of power distribution objects arranged according to next-generation methodology (i.e., using multiple PowerBoss power distributors in addition to the on-board power distributor). SEQUENCE OF PowerDistribNextGen .1.3.6.1.4.1.3052.20.1.5.4.1 |
pdnEntryEntry for table of power distribution objects arranged according to next-generation methodology (i.e., using multiple PowerBoss power distributors in addition to the on-board power distributor). PowerDistribNextGen .1.3.6.1.4.1.3052.20.1.5.4.1.1 |
pdnIndexPDIndex for table of power distribution objects, specifically the index that refers to which power distributor. A value of 200 means the internal power distributor. A value from 1 to 16 refers to an external power distributor (PowerBoss), and is the same value as esIndexES, which refers to the PowerBoss as an EventSensor in the eventSensorStatus object table. In other words, pdnIndexPD is the same as esIndexES: esIndexES is used to refer to the PowerBoss as an eventsensor (i.e., control outputs), while pdnIndexPD is used to refer to the PowerBoss when used for power distribution monitoring (i.e., to alarm on output current/voltage/fuse status).ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.1 |
pdnIndexOutputIndex for table of power distribution objects, specifically the index that refers to which output on the power distributor specified by pdnIndexPD. For objects where the output is irrelevant, this index should be 1.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.2 |
pdnConfigThe number of outputs on the power distributor specified by pdnIndexPD. pdnIndexOutput should be 1 for this object.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.3 |
pdnMainCurrentInEventStateThe event state of the current (i.e. Amps) event of the power distributor specified by pdnIndexPD. pdnIndexOutput should be 1 for this object. Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High', 'Very High'.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.4 |
pdnMainCurrentValueThe current drawn, in mA, for the power distributor specified by pdnIndexPD. If pdnIndexPD is 200 then this is the internal power distributor and refers to the current drawn by the S572 (which is comprised of the internal power distributor and ancillary internal equipment) and all equipment powered by the S572's internal power outputs. If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) and refers to the current drawn by that PowerBoss and all equipment powered by that PowerBoss. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.5 |
pdnMainCurrentValueStrEssentially pdnMainCurrentValue formatted as a string in units of Amps, with 3 decimal places. pdnIndexOutput should be 1 for this object.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.6 |
pdnMainCurrentDeadbandThe deadband, in mA, for the main current sensor for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.7 |
pdnMainCurrentVHighCurrentThe current, in mA, for the main current sensor's Very High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.8 |
pdnMainCurrentHighCurrentThe current, in mA, for the main current sensor's High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.9 |
pdnMainCurrentLowCurrentThe current, in mA, for the main current sensor's Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.10 |
pdnMainCurrentVLowCurrentThe current, in mA, for the main current sensor's Very Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.11 |
pdnMainVoltageInEventStateThe event state of the voltage event of the power distributor specified by pdnIndexPD. pdnIndexOutput should be 1 for this object. Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High', 'Very High'.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.12 |
pdnMainVoltageValueThe voltage, in mV, at the power distributor specified by pdnIndexPD. If pdnIndexPD is 200 then this is the internal power distributor and refers to the voltage at the S572 (which is comprised of the internal power distributor and ancillary internal equipment) and all equipment powered by the S572's internal power outputs. If pdnIndexPD is 1-16 then this is an external power distributor (PowerBoss) and refers to the voltage at that PowerBoss and all equipment powered by that PowerBoss. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.13 |
pdnMainVoltageValueStrEssentially pdnMainVoltageValue formatted as a string in units of Volts, with 3 decimal places. pdnIndexOutput should be 1 for this object.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.14 |
pdnMainVoltageDeadbandThe deadband, in mV, for the main voltage sensor for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.15 |
pdnMainVoltageVHighVoltageThe voltage, in mA, for the main voltage sensor's Very High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.16 |
pdnMainVoltageHighVoltageThe voltage, in mV, for the main voltage sensor's High event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.17 |
pdnMainVoltageLowVoltageThe voltage, in mV, for the main voltage sensor's Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.18 |
pdnMainVoltageVLowVoltageThe voltage, in mV, for the main voltage sensor's Very Low event threshold, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.19 |
pdnMainPowerValueThe power, in Watts, for the power distributor specified by pdIndexPD. pdnIndexOutput should be 1 for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.20 |
pdnMainPowerValueStrThe power, in Watts, for the power distributor specified by pdIndexPD, formatted as a string with the unit name 'Watts'. pdnIndexOutput should be 1 for this object.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.21 |
pdnOutputCurrentInEventStateThe event state of the current (i.e. Amps) event of the power distributor output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=200 and pdnIndexOutput=2, this refers to power output #2 of the internal power distributor. Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High', 'Very High'.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.22 |
pdnOutputCurrentValueThe current drawn, in mA, for the power distributor output specified by pdnIndexPD and pdIndexOutput. If pdnIndexPD is 200 then this is the internal power distributor and refers to the current drawn by a specific power output on the S572. If pdIndexPD is 3 then this is an external power distributor (PowerBoss) identified as 'power distributor 3' and refers to the current drawn by a specific power output on that PowerBoss. The specific power output is specified by pdIndexOutput.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.23 |
pdnOutputCurrentValueStrEssentially pdnOutputCurrentValue formatted as a string in units of Amps, with 3 decimal places.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.24 |
pdnOutputCurrentDeadbandThe deadband, in mA, for the main current sensor for the power distributor specified by pdIndexPD. The power output is specified by pdnIndexOutput.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.25 |
pdnOutputCurrentVHighCurrentThe current, in mA, for a specific power output's current sensor Very High event threshold, for the power distributor specified by pdIndexPD. The power output is specified by pdnIndexOutput.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.26 |
pdnOutputCurrentHighCurrentThe current, in mA, for a specific power output's current sensor High event threshold, for the power distributor specified by pdIndexPD. The power output is specified by pdnIndexOutput for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.27 |
pdnOutputCurrentLowCurrentThe current, in mA, for a specific power output's current sensor Low event threshold, for the power distributor specified by pdIndexPD. The power output is specified by pdnIndexOutput for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.28 |
pdnOutputCurrentVLowCurrentThe current, in mA, for a specific power output's current sensor Very Low event threshold, for the power distributor specified by pdIndexPD. The power output is specified by pdnIndexOutput for this object.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.29 |
pdnOutputFuseInEventStateThe event state of the fuse event of the power distributor output specified by pdnIndexPD and pdnIndexOutput. E.g., for pdnIndexPD=14 and pdnIndexOutput=2, this refers to power output #2 of the external power distributor (PowerBoss), identified as 'power distributor 14'. Possible values for this object are: 'Very Low', 'Low', 'Normal', 'High', 'Very High'. This object exists only for power distributors with fuse monitoring support.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.30 |
pdnOutputFuseValueStrThe state of the fuse of the power distributor output specified by pdnIndexPD and pdnIndexOutput. Possible values for this object are: 'BLOWN' and 'OK'. This object exists only for power distributors with fuse monitoring support.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.31 |
pdnMainCombinedStatusCombined status string intended to be parsed by NMS: format: voltageColorCode`voltageEventState`voltageValue`mainCurrentColorCode`mainCurrentEventState`mainCurrentValue`deviceCurrentValue`mainPowerValuero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.32 |
pdnOutputCombinedStatusBlock1Combined status string intended to be parsed by NMS: format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.33 |
pdnOutputCombinedStatusBlock2Combined status string intended to be parsed by NMS: format: numInBlock~outputCurrentColorCode1`outputCurrentEventState1`outputCurrentValue1`fuseColorCode1`fuseValue1~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.34 |
pdnDeviceCurrentValueCurrent drawn by device in mA. For the internal power distributor device, this is the current drawn by the SiteBoss 571. For an external power distributor device (PowerBoss), this is the current drawn by the PowerBoss. This object exists only for power distributors with device current monitoring support.ro Integer32 .1.3.6.1.4.1.3052.20.1.5.4.1.1.35 |
pdnDeviceCurrentValueStrCurrent drawn by device as a string with units (Amps). For the internal power distributor device, this is the current drawn by the SiteBoss 571. For an external power distributor device (PowerBoss), this is the current drawn by the PowerBoss. This object exists only for power distributors with device current monitoring support.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.4.1.1.36 |
pdSystem OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.1.5.5 |
pdSystemCurrentTotal current drawn by all power distributors in system; that is, the sum of all pdnMainCurrentValue objects for all connected power distributors: internal and external.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.5.1 |
pdSystemPowerTotal power used by all power distributors in system; that is, the sum of all pdnMainPowerValue objects for all connected power distributors: internal and external.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.5.2 |
pdSystemLowVoltShutdownEnablePower Distribution Low Voltage Shutdown Enabled.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.5.5.3 |
pdSystemLowVoltShutdownLowValuePower Distribution Low Voltage Shutdown Low Value.rw Integer32 .1.3.6.1.4.1.3052.20.1.5.5.4 |
pdSystemLowVoltShutdownNormalValuePower Distribution Low Voltage Shutdown Normal Value.rw Integer32 .1.3.6.1.4.1.3052.20.1.5.5.5 |
fuelSensorStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.1.6 |
fsStatusTableFuel sensor status table SEQUENCE OF FSStatus .1.3.6.1.4.1.3052.20.1.6.1 |
fsStatusEntryFuel sensor status table entry FSStatus .1.3.6.1.4.1.3052.20.1.6.1.1 |
fsStatusIndexIndex for fuel sensorsro Integer32 .1.3.6.1.4.1.3052.20.1.6.1.1.1 |
fsStatusNameFuel sensor namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.6.1.1.2 |
fsStatusDeviceStateFuel sensor device statero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.6.1.1.3 |
fsStatusVolumeValueStringFuel volume. Range is -2,147,483,648 to 2,147,483,647. This value reads -999 when the fuel sensor is disconnectedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.6.1.1.4 |
fsStatusVolumePercentLevelHeight of the fluid in the tank expressed as a percentage of the tank height, in hundredths of a percent.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.6.1.1.7 |
fsStatusVolumeInEventStateCurrent event status of the fuel sensor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.6.1.1.8 |
fsStatusCombinedCombined status string intended to be parsed by NMS: deviceState`deviceStateColorCode`percentRounded`valueAsFloat`volumeEventState`volumeEventStateColorCode`capacity`units`namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.6.1.1.9 |
wirelessModemStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.1.7 |
wmsStatusWireless modem statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.1 |
wmsSignalWireless modem Signal strengthro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.2 |
wmsRSSIWireless modem Signal strength (RSSI)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.3 |
wmsBERWireless modem Bit Error Ratero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.4 |
wmsUpdatedWireless modem info last update timero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.5 |
wmsRegistrationWireless modem registration statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.6 |
wmsLACWireless modem Location Area Codero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.7 |
wmsCellIDWireless modem Cell IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.8 |
wmsIMSIWireless modem Internation Mobile Subscriber Identity numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.9 |
wmsPhnumWireless modem phone numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.10 |
wmsLocalIPLocal IP address of modem on wireless networkro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.11 |
wmsMgfIDWireless modem manufacturer IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.12 |
wmsModelIDWireless modem model IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.13 |
wmsIMEIWireless modem International Mobile Equipment Identity numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.14 |
wmsRevIDWireless modem revision IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.15 |
wmsNetNameWireless modem network namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.16 |
wmsGPRSStatusWireless modem (E)GPRS statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.17 |
wmsBandWireless modem bandro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.18 |
wmsChannelWireless modem channelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.19 |
wmsCountryCodeWireless modem country codero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.20 |
wmsNetCodeWireless modem network codero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.21 |
wmsPLMNColorWireless modem PLMN colorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.22 |
wmsBScolorWireless modem BS colorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.23 |
wmsMpRACHWireless modem max power RACHro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.24 |
wmsMinRxLevelWireless modem minimum receive levelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.25 |
wmsBaseCoeffWireless modem base coefficientro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.26 |
wmsSIMStatusWWireless modem SIM statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.27 |
wmsICCIDWireless modem SIM ICCIDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.28 |
wmsModemTypeWireless modem typero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.7.29 |
acPowerMonitorStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.1.8 |
acpmStatusTableAC power monitor status table SEQUENCE OF ACPMStatus .1.3.6.1.4.1.3052.20.1.8.1 |
acpmStatusEntryAC power monitor status table entry ACPMStatus .1.3.6.1.4.1.3052.20.1.8.1.1 |
acpmsIndexIndex for AC power monitorsro Integer32 .1.3.6.1.4.1.3052.20.1.8.1.1.1 |
acpmsNameName for the AC power monitor device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.2 |
acpmsAvgVoltageValueStrAverage voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1). This could be either the average of the phase voltages, or the sum of the phase voltages, depending on device configuration.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.3 |
acpmsAvgVoltageMinStrMinimum average voltage value since last reset, in volts.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.4 |
acpmsAvgVoltageMaxStrMaximum average voltage value since last reset, in volts.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.5 |
acpmsAvgVoltageAvgStrAverage average voltage value since last reset, in volts. This is the unit's average of its measurements of the average voltage reported by the AC power monitor device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.6 |
acpmsAvgVoltageInEventStateEvent state of this AC power monitor voltage (Low, Normal, High, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.7 |
acpmsVoltagePhaseAValueStrPhase A voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.8 |
acpmsVoltagePhaseBValueStrPhase B voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.9 |
acpmsVoltagePhaseCValueStrPhase C voltage, in volts. This is calculated using the formula (register * PT ratio * 0.1).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.10 |
acpmsAvgCurrentValueStrAverage current, in amps. This is calculated using the formula (register * CT ratio * 0.001). This could be either the average of the phase currents, or the sum of the phase currents, depending on device configuration.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.11 |
acpmsAvgCurrentMinStrMinimum average current value since last reset, in amps.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.12 |
acpmsAvgCurrentMaxStrMaximum average current value since last reset, in amps.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.13 |
acpmsAvgCurrentAvgStrAverage average current value since last reset, in amps. This is the unit's average of its measurements of the average current reported by the AC power monitor device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.14 |
acpmsAvgCurrentInEventStateEvent state of this AC power monitor current (Low, Normal, High, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.15 |
acpmsCurrentPhaseAValueStrPhase A current, in amps. This is calculated using the formula (register * CT ratio * 0.001).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.16 |
acpmsCurrentPhaseBValueStrPhase B current, in amps. This is calculated using the formula (register * CT ratio * 0.001).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.17 |
acpmsCurrentPhaseCValueStrPhase C current, in amps. This is calculated using the formula (register * CT ratio * 0.001).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.18 |
acpmsAvgFreqValueStrFrequency, in hertz. On the YD2010, this is calculated using the formula (register * 0.00106813). On the WattsOn, this is calculated using the formula (register * 0.1).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.19 |
acpmsAvgFreqMinStrMinimum frequency value since last reset, in hertz.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.20 |
acpmsAvgFreqMaxStrMaximum frequency value since last reset, in hertz.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.21 |
acpmsAvgFreqAvgStrAverage frequency value since last reset, in hertz. This is the unit's average of its measurements of the average frequency reported by the AC power monitor device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.22 |
acpmsAvgFreqInEventStateEvent state of this AC power monitor frequency (Low, Normal, High, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.23 |
acpmsTRPValueStrTotal real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn models, this is calculated using the formula (register * PT * CT).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.24 |
acpmsTRPMinStrMinimum total real power value since last reset, in watts.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.25 |
acpmsTRPMaxStrMaximum total real power value since last reset, in watts.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.26 |
acpmsTRPAvgStrAverage total real power value since last reset, in watts. This is the unit's average of its measurements of the average total real power reported by the AC power monitor device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.27 |
acpmsTRPInEventStateEvent state of this AC power monitor total real power (Low, Normal, High, etc.).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.28 |
acpmsRPPhaseAValueStrPhase A real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.29 |
acpmsRPPhaseBValueStrPhase B real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.30 |
acpmsRPPhaseCValueStrPhase C real power, in watts. On the YD2010, this is calculated using the formula (register * PT ratio * CT ratio * Urg * 0.4), where Urg is the voltage range taken from register 0x30A. On the WattsOn, this is calculated using the formula (register * PT * CT).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.31 |
acpmsCombinedCombined status string intended to be parsed by NMS: name`deviceState`deviceStateColorCode`voltage`current`frequency`power~voltageEventState`voltageColorCode`currentEventState`currentColorCode`frequencyEventState`freuencyColorCode`powerEventState`powerColorCodero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.32 |
acpmsTPFValueStrTotal power factor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.33 |
acpmsTPFMinStrTotal power factor minimum value since last reset.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.34 |
acpmsTPFMaxStrTotal power factor maximum value since last reset.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.35 |
acpmsTPFAvgStrTotal power factor average value since last reset.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.36 |
acpmsTPFInEventStateTotal power factor event state.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.37 |
acpmsPFPhaseAValueStrPhase A power factor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.38 |
acpmsPFPhaseBValueStrPhase B power factor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.39 |
acpmsPFPhaseCValueStrPhase C power factor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.40 |
acpmsTRcPValueStrTotal reactive power, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.41 |
acpmsTRcPMinStrTotal reactive power minimum value since last reset, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.42 |
acpmsTRcPMaxStrTotal reactive power maximum value since last reset, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.43 |
acpmsTRcPAvgStrTotal reactive power average value since last reset, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.44 |
acpmsRcPPhaseAValueStrPhase A reactive power, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.45 |
acpmsRcPPhaseBValueStrPhase B reactive power, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.46 |
acpmsRcPPhaseCValueStrPhase C reactive power, in VAR.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.47 |
acpmsTAPValueStrTotal apparent power, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.48 |
acpmsTAPMinStrTotal apparent power minimum value since last reset, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.49 |
acpmsTAPMaxStrTotal apparent power maximum value since last reset, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.50 |
acpmsTAPAvgStrTotal apparent power average value since last reset, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.51 |
acpmsAPPhaseAValueStrPhase A apparent power, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.52 |
acpmsAPPhaseBValueStrPhase B apparent power, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.53 |
acpmsAPPhaseCValueStrPhase C apparent power, in VA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.8.1.1.54 |
acpmsTotalEnergyWhTotal energy, in Wh.ro Integer32 .1.3.6.1.4.1.3052.20.1.8.1.1.55 |
acpmsTotalEnergyVARTotal reactive energy, in VAR.ro Integer32 .1.3.6.1.4.1.3052.20.1.8.1.1.56 |
acpmsTotalEnergyVATotal apparent energy, in VA.ro Integer32 .1.3.6.1.4.1.3052.20.1.8.1.1.57 |
aisgStatus OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.1.9 |
aisgsPowerAISG power statero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.1 |
aisgsBaseStationIDAISG base station IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.2 |
aisgsALDTableThe table of what AISG ALDs (Antenna Line Devices) are attached to the unit. SEQUENCE OF AISGALD .1.3.6.1.4.1.3052.20.1.9.3 |
aisgsALDEntryTable entry for AISG ALD table AISGALD .1.3.6.1.4.1.3052.20.1.9.3.1 |
aisgsALDIndexThis number refers to an ALD; it is the ALD # as shown in the web UI and CLI.ro Integer32 .1.3.6.1.4.1.3052.20.1.9.3.1.1 |
aisgsALDSectorIDThe sector ID of this ALD.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.2 |
aisgsALDTypeThe type of ALD (SR or MR).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.3 |
aisgsALDDescriptionUser-defined description for this ALD.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.4 |
aisgsALDStatusStatus of this ALD (i.e., OFF, OK, UNRSP, ALARM).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.5 |
aisgsALDIDThe ID/serial number of this ALD.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.6 |
aisgsALDTiltThe current tilt value of this ALD.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.7 |
aisgsALDHwVersionThe hardware version of this ALD.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.8 |
aisgsALDSwVersionThe software version of this ALD.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.9 |
aisgsALDModelThe model number of this ALD.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.10 |
aisgsALDAntennaModelThe model number of the antenna associated with this ALD. Note that not all ALDs have this.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.11 |
aisgsALDMinTiltThe minimum tilt value of this ALD, as determined by the ALD's loaded configuration file. A nonsensical value here indicates that the ALD is not configured.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.12 |
aisgsALDMaxTiltThe maximum tilt value of this ALD, as determined by the ALD's loaded configuration file. A nonsensical value here indicates that the ALD is not configured.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.13 |
aisgsALDAISGVersionThe AISG version of this ALD. E.g., 1.1, 2.0.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.3.1.14 |
aisgsFileTableThe table of what AISG files are currently loaded on the unit. SEQUENCE OF AISGFile .1.3.6.1.4.1.3052.20.1.9.4 |
aisgsFileEntryTable entry for AISG File table AISGFile .1.3.6.1.4.1.3052.20.1.9.4.1 |
aisgsFileIndexIndex for AISG File table. This defines the local store (local to the unit) of files residing on the unit that are available to be loaded onto ALDs.ro Integer32 .1.3.6.1.4.1.3052.20.1.9.4.1.1 |
aisgsFileNameName of AISG file (specified by user).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.4.1.2 |
aisgsFileTypeType of AISG file (e.g., SOFTWARE or CONFIG)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.4.1.3 |
aisgsFileVersionVersion of AISG file as reported by the ALD running this software. This is for SOFTWARE files, so that the unit can know when (during auto config) it does not need to load software onto an ALD (i.e., if the ALD already has this software version loaded).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.4.1.4 |
aisgsAutoTableThe table of AISG automatic configuration slots on the unit. These slots describe what the unit should do automatically (load software, load config, calibrate, tilt) upon finding the ALD during a scan, on the specific basis of any ALD matching the vendor and ALD model defined in a row of this table. SEQUENCE OF AISGAuto .1.3.6.1.4.1.3052.20.1.9.5 |
aisgsAutoEntryTable entry for AISG Auto table AISGAuto .1.3.6.1.4.1.3052.20.1.9.5.1 |
aisgsAutoIndexIndex for AISG Auto table.ro Integer32 .1.3.6.1.4.1.3052.20.1.9.5.1.1 |
aisgsAutoVendorThe two-letter vendor code for this automatic configuration table row.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.5.1.2 |
aisgsAutoALDModelThe ALD model number this automatic configuration table row.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.5.1.3 |
aisgsAutoSoftwareThe software file name of this automatic configuration table row.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.5.1.4 |
aisgsAutoConfigThe configuration file name of this automatic configuration table row.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.5.1.5 |
aisgsAutoTiltThe tilt value for this automatic configuration table row. Any ALD not already auto-configured by the unit will be tilted to this value, if its vendor and model number match the vendor and ALD model number of this table row.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.5.1.6 |
aisgsAAATableThe table of AISG antenna-ALD associations slots on the unit. These slots describe what antenna serial number and what sector ID the unit should assign to an ALD that is undergoing automatic configuration. SEQUENCE OF AISGAAA .1.3.6.1.4.1.3052.20.1.9.6 |
aisgsAAAEntryTable entry for AISG AAA table AISGAAA .1.3.6.1.4.1.3052.20.1.9.6.1 |
aisgsAAAIndexIndex for AISG AAA table.ro Integer32 .1.3.6.1.4.1.3052.20.1.9.6.1.1 |
aisgsAAAALDIDThe ID/serial number of the ALD for this AAA table row.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.6.1.2 |
aisgsAAAAntennaSNThe user-specified antenna serial number for this AAA table row. An ALD that the unit finds with this ID/serial number will be assigned this antenna serial number. This happens only during auto-configuration of the ALD, which happens only once for an ALD.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.6.1.3 |
aisgsAAASectorIDThe user-specified sector ID for this AAA table row. An ALD that the unit finds with this ID/serial number will be assigned this sector ID. This happens only during auto-configuration of the ALD, which happens only once for an ALD.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.1.9.6.1.4 |
config OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2 |
eventSensorBasics OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.1 |
esNumberEventSensorsThe number of EventSensors recognized by the unit, including the internal EventSensor. Range: 1-17ro Integer32 .1.3.6.1.4.1.3052.20.2.1.1 |
esTableThe table of what EventSensors are attached to the unit, including the internal EventSensor SEQUENCE OF ESExist .1.3.6.1.4.1.3052.20.2.1.2 |
esEntryTable entry for EventSensor table ESExist .1.3.6.1.4.1.3052.20.2.1.2.1 |
esIndexThis number refers to an EventSensor; it has the same meaning as the esIndexES object (see above), except that this object is used only within the esTable branch. This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndex=2 will now refer to that particular EventSensor.ro Integer32 .1.3.6.1.4.1.3052.20.2.1.2.1.1 |
esNameThe name of the EventSensorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.2 |
esIDThe factory-assigned ID of the EventSensorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.3 |
esNumberTempSensorsThe number of temperature sensors on the EventSensorro Integer32 .1.3.6.1.4.1.3052.20.2.1.2.1.4 |
esTempReportingModeDescription of how temperature values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.5 |
esNumberCCsThe number of contact closures on the EventSensor.ro Integer32 .1.3.6.1.4.1.3052.20.2.1.2.1.6 |
esCCReportingModeDescription of how CC values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.7 |
esNumberHumidSensorsThe number of humidity sensors on the EventSensor.ro Integer32 .1.3.6.1.4.1.3052.20.2.1.2.1.8 |
esHumidReportingModeDescription of how humidity sensor values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.9 |
esNumberNoiseSensorsThe number of noise sensors on the EventSensor.ro Integer32 .1.3.6.1.4.1.3052.20.2.1.2.1.10 |
esNoiseReportingModeDescription of how noise sensor values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.11 |
esNumberAirflowSensorsThe number of airflow sensors on the EventSensor.ro Integer32 .1.3.6.1.4.1.3052.20.2.1.2.1.12 |
esAirflowReportingModeDescription of how airflow sensor values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.13 |
esNumberAnalogThe number of analog inputs on the EventSensor.ro Integer32 .1.3.6.1.4.1.3052.20.2.1.2.1.14 |
esAnalogReportingModeDescription of how analog input values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.15 |
esNumberOutputsThe number of outputs (relay or power) on the EventSensorro Integer32 .1.3.6.1.4.1.3052.20.2.1.2.1.16 |
esOutputReportingModeDescription of how output values should be interpreted.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.17 |
esTempCombinedStatusCombined status string intended to be parsed by NMS: name`value`scale`eventState`eventColorCodero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.18 |
esCCCombinedStatusBlock1Combined status string intended to be parsed by NMS: numInBlock~name1`value1`eventColorCode1`alias1~name2`value2`eventColorCode2`alias2~...name8`value8`eventColorCode8`alias8ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.19 |
esCCCombinedStatusBlock2Combined status string intended to be parsed by NMS: numInBlock~name9`value9`eventColorCode9`alias9~name10`value10`eventColorCode10`alias10~...name16`value16`eventColorCode16`alias16ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.20 |
esCCCombinedStatusBlock3Combined status string intended to be parsed by NMS: numInBlock~name17`value17`eventColorCode17`alias17~name18`value18`eventColorCode18`alias18~...name24`value24`eventColorCode24`alias24ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.21 |
esCCCombinedStatusBlock4Combined status string intended to be parsed by NMS: numInBlock~name25`value25`eventColorCode25`alias25~name26`value26`eventColorCode26`alias26~...name32`value32`eventColorCode32`alias32ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.22 |
esCCCombinedStatusBlock5Combined status string intended to be parsed by NMS: numInBlock~name33`value33`eventColorCode33`alias33~name34`value34`eventColorCode34`alias35~...name40`value40`eventColorCode40`alias40ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.23 |
esCCCombinedStatusBlock6Combined status string intended to be parsed by NMS: numInBlock~name41`value41`eventColorCode41`alias41~name42`value42`eventColorCode42`alias43~...name48`value48`eventColorCode48`alias48ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.24 |
esCCCombinedStatusBlock7Combined status string intended to be parsed by NMS: numInBlock~name49`value49`eventColorCode49`alias49~name50`value50`eventColorCode50`alias50~...name56`value56`eventColorCode56`alias56ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.25 |
esCCCombinedStatusBlock8Combined status string intended to be parsed by NMS: numInBlock~name57`value57`eventColorCode57`alias57~name57`value57`eventColorCode564`alias57~...name64`value64`eventColorCode64`alias64ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.26 |
esHumidCombinedStatusCombined status string intended to be parsed by NMS: name`value`eventState`eventColorCodero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.27 |
esAnalogCombinedStatusBlock1Combined status string intended to be parsed by NMS: numInBlock~name1`value1`units1`eventState`eventColorCode1~name2`value2`units2`eventState`eventColorCode2~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.28 |
esAnalogCombinedStatusBlock2Combined status string intended to be parsed by NMS: numInBlock~name9`value9`units9`eventState9`eventColorCode9~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.29 |
esAnalogCombinedStatusBlock3Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.30 |
esAnalogCombinedStatusBlock4Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.31 |
esAnalogCombinedStatusBlock5Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.32 |
esAnalogCombinedStatusBlock6Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.33 |
esOutputCombinedStatusBlock1Combined status string intended to be parsed by NMS: numInBlock~namex`valuex`unitsx`eventStatex`eventColorCodex~...ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.34 |
esOutputCombinedStatusBlock2Combined status string intended to be parsed by NMS: numInBlock`namex`valuex`aliasx~namey`valuey`aliasy~...namez`valuez`aliaszro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.2.1.35 |
esNewSensorsString representing the number of new (attached but unconfigured) EventSensorsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.1.3 |
eventSensorPointConfig OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.2 |
esPointConfigTempTableThis table organizes 3 basic attributes of temperature sensor points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number (always 1 for temp sensors) Points are referenced by a point config index. The point config index is a string of 2 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor within the context of this emperature point config table ; namely, which EventSensor, and which sensor (a.k.a. point) (always 1 for temperature sensors). SEQUENCE OF ESPointConfigTemp .1.3.6.1.4.1.3052.20.2.2.1 |
esPointConfigTempEntryEntry for EventSensor point config temperature table ESPointConfigTemp .1.3.6.1.4.1.3052.20.2.2.1.1 |
espcTempIndexESThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config temperature table; namely, which EventSensor, and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndexES=2 will now refer to that particular EventSensor.ro Integer32 .1.3.6.1.4.1.3052.20.2.2.1.1.1 |
espcTempIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcTempIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of temperature point configuration.ro Integer32 .1.3.6.1.4.1.3052.20.2.2.1.1.2 |
espcTempEnableON/OFF enable this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.3 |
espcTempScaleScale (C/F) for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.4 |
espcTempDeadbandDeadband for this temperature sensor (in floating-point format)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.5 |
espcTempVHighTempVery high temperature event threshold for this temperature sensor (in floating-point format)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.6 |
espcTempVHighActionsVery high temperature event actions for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.7 |
espcTempVHighTrapnumVery high temperature event trap number for this temperature sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.1.1.8 |
espcTempVHighClassVery high temperature event class for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.9 |
espcTempHighTempHigh temperature event threshold for this temperature sensor (in floating-point format)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.10 |
espcTempHighActionsHigh temperature event actions for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.11 |
espcTempHighTrapnumHigh temperature event trap number for this temperature sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.1.1.12 |
espcTempHighClassHigh temperature event class for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.13 |
espcTempNormalActionsReturn-to-normal event actions for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.14 |
espcTempNormalTrapnumReturn-to-normal event trap number for this temperature sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.1.1.15 |
espcTempNormalClassReturn-to-normal event class for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.16 |
espcTempLowTempLow temperature event threshold for this temperature sensor (in floating-point format)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.17 |
espcTempLowActionsLow temperature event actions for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.18 |
espcTempLowTrapnumLow temperature event trap number for this temperature sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.1.1.19 |
espcTempLowClassLow temperature event class for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.20 |
espcTempVLowTempVery Low temperature event threshold for this temperature sensor (in floating-point format)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.21 |
espcTempVLowActionsVery Low temperature event actions for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.22 |
espcTempVLowTrapnumVery Low temperature event trap number for this temperature sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.1.1.23 |
espcTempVLowClassVery Low temperature event class for this temperature sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.1.1.24 |
esPointConfigCCTableThis table organizes 3 basic attributes of contact closure points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this contact closure point config table ; namely, which EventSensor and which sensor. SEQUENCE OF ESPointConfigCC .1.3.6.1.4.1.3052.20.2.2.2 |
esPointConfigCCEntryEntry for EventSensor point config contact closure table ESPointConfigCC .1.3.6.1.4.1.3052.20.2.2.2.1 |
espcCCIndexESThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.ro Integer32 .1.3.6.1.4.1.3052.20.2.2.2.1.1 |
espcCCIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcCCIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration.ro Integer32 .1.3.6.1.4.1.3052.20.2.2.2.1.2 |
espcCCEnableON/OFF enable for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.2.1.3 |
espcCCNameName for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.2.1.4 |
espcCCEventStateEvent state for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.2.1.5 |
espcCCThresholdEvent threshold (seconds) for this contact closurerw Integer32 .1.3.6.1.4.1.3052.20.2.2.2.1.6 |
espcCCEventActionsEvent actions for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.2.1.7 |
espcCCEventTrapnumEvent trap number for this contact closurerw Integer32 .1.3.6.1.4.1.3052.20.2.2.2.1.8 |
espcCCEventClassEvent class for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.2.1.9 |
espcCCNormalActionsReturn-to-normal actions for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.2.1.10 |
espcCCNormalTrapnumReturn-to-normal trap number for this contact closurerw Integer32 .1.3.6.1.4.1.3052.20.2.2.2.1.11 |
espcCCNormalClassReturn-to-normal class for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.2.1.12 |
espcCCAlarmAliasEvent alias for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.2.1.13 |
espcCCNormalAliasReturn-to-normal alias for this contact closurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.2.1.14 |
espcCCNormalThresholdEvent threshold (seconds) for this contact closure to return to normalrw Integer32 .1.3.6.1.4.1.3052.20.2.2.2.1.15 |
espcCCOverrideGlobalReminderOverride global reminder interval (evReminderInterval) for this CC.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.2.1.16 |
espcCCReminderIntervalIndividual reminder interval for this CC, applicable when the global reminder is overriden.rw Integer32 .1.3.6.1.4.1.3052.20.2.2.2.1.17 |
esPointConfigHumidTableThis table organizes 3 basic attributes of humidity points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number (always 1 for humidity sensors) Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this humidity point config table ; namely, which EventSensor and which sensor. SEQUENCE OF ESPointConfigHumid .1.3.6.1.4.1.3052.20.2.2.3 |
esPointConfigHumidEntryEntry for EventSensor point config humidity table ESPointConfigHumid .1.3.6.1.4.1.3052.20.2.2.3.1 |
espcHumidIndexESThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.ro Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.1 |
espcHumidIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcHumidIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration.ro Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.2 |
espcHumidEnableON/OFF enable for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.3.1.3 |
espcHumidDeadbandDeadband for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.4 |
espcHumidVHighHumidVery high event threshold for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.5 |
espcHumidVHighActionsVery high event actions for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.3.1.6 |
espcHumidVHighTrapnumVery high event trap number for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.7 |
espcHumidVHighClassVery high event class for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.3.1.8 |
espcHumidHighHumidHigh event threshold for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.9 |
espcHumidHighActionsHigh event actions for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.3.1.10 |
espcHumidHighTrapnumHigh event trap number for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.11 |
espcHumidHighClassHigh event class for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.3.1.12 |
espcHumidNormalActionsReturn-to-normal actions for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.3.1.13 |
espcHumidNormalTrapnumReturn-to-normal trap number for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.14 |
espcHumidNormalClassReturn-to-normal class for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.3.1.15 |
espcHumidLowHumidLow event threshold for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.16 |
espcHumidLowActionsLow event actions for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.3.1.17 |
espcHumidLowTrapnumLow event trap number for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.18 |
espcHumidLowClassLow event class for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.3.1.19 |
espcHumidVLowHumidVery low event threshold for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.20 |
espcHumidVLowActionsVery low event actions for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.3.1.21 |
espcHumidVLowTrapnumVery low event trap number for this humidity sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.3.1.22 |
espcHumidVLowClassVery low event class for this humidity sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.3.1.23 |
esPointConfigAITableThis table organizes 3 basic attributes of analog input points. A point is a particular sensor on an EventSensor. The 3 point attributes organizes in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this analog input point config table ; namely, which EventSensor and which sensor. SEQUENCE OF ESPointConfigAnalogInput .1.3.6.1.4.1.3052.20.2.2.5 |
esPointConfigAIEntryEntry for EventSensor point config analog input table ESPointConfigAnalogInput .1.3.6.1.4.1.3052.20.2.2.5.1 |
espcAIIndexESThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.ro Integer32 .1.3.6.1.4.1.3052.20.2.2.5.1.1 |
espcAIIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcAIIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of contact closure point configuration.ro Integer32 .1.3.6.1.4.1.3052.20.2.2.5.1.2 |
espcAIEnableON/OFF for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.3 |
espcAIDeadbandDeadband for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.5 |
espcAIVhighValueVery high event threshold (decivolts or tenths of milliamps) for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.6 |
espcAIVhighActionsVery high event actions for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.7 |
espcAIVhighTrapnumVery high event trap number for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.5.1.8 |
espcAIVhighClassVery high event class for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.9 |
espcAIHighValueHigh event threshold (decivolts or tenths of milliamps) for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.10 |
espcAIHighActionsHigh event actions for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.11 |
espcAIHighTrapnumHigh event trap number for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.5.1.12 |
espcAIHighClassHigh event class for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.13 |
espcAINormalActionsReturn-to-normal actions for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.14 |
espcAINormalTrapnumReturn-to-normal trap number for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.5.1.15 |
espcAINormalClassReturn-to-normal class for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.16 |
espcAILowValueLow event threshold (decivolts or tenths of milliamps) for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.17 |
espcAILowActionsLow event actions for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.18 |
espcAILowTrapnumLow event trap number for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.5.1.19 |
espcAILowClassLow event class for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.20 |
espcAIVlowValueVery low event threshold (decivolts or tenths of milliamps) for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.21 |
espcAIVlowActionsVery low event actions for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.22 |
espcAIVlowTrapnumVery low event actions for this analog input sensorrw Integer32 .1.3.6.1.4.1.3052.20.2.2.5.1.23 |
espcAIVlowClassVery low event class for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.24 |
espcAIConvUnitNameConverstion unit name for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.25 |
espcAIConvHighValueConversion high value for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.26 |
espcAIConvHighUnitConversion high unit value for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.27 |
espcAIConvLowValueConversion low value for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.29 |
espcAIConvLowUnitConversion unit low unit value for this analog input sensorrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.30 |
espcAIDisplayFormatAnalog input display formatrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.5.1.32 |
esPointConfigOutputTableThis table organizes configuration items for output points. A point is a particular sensor on an EventSensor. The 3 point attributes organized in this table are: 1. the configuration item (e.g., enable, name, etc.) 2. the eventsensor on which this point resides 3. the point number Points are referenced by a point config index. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the context of this output config table ; namely, which EventSensor and which sensor. SEQUENCE OF ESPointConfigOutput .1.3.6.1.4.1.3052.20.2.2.6 |
esPointConfigOutputEntryEntry for EventSensor point config output table ESPointConfigOutput .1.3.6.1.4.1.3052.20.2.2.6.1 |
espcOutputIndexESThe part of the point index that refers to an EventSensor. The point config index is a string of 2 numbers separated by a period. It contains all the information necessary for getting a piece of data off an event sensor within the the context of the eventsensor point config contact closure table; namely, which EventSensor and which sensor (a.k.a. point). This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.ro Integer32 .1.3.6.1.4.1.3052.20.2.2.6.1.1 |
espcOutputIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with espcOutputIndexES (which EventSensor) uniquely defines each point attached to a unit within the context of output point configuration.ro Integer32 .1.3.6.1.4.1.3052.20.2.2.6.1.2 |
espcOutputEnableEnables the output event for this output. This has no effect on whether the relay changes state, only on whether a state change triggers an event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.3 |
espcOutputActiveStateWhich state is considered the active state: energized/de-energized.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.4 |
espcOutputTypeOutput type: RELAY, POWER, SSR, TTL.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.5 |
espcOutputAliasValueOutput alias corresponding to its event state.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.6 |
espcOutputAliasColorOutput color corresponding to its event state.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.7 |
espcOutputActiveAliasAlias for the output active state.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.10 |
espcOutputActiveColorOutput color (as rendered in the web UI, in RGB hex format) corresponding to the output active state.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.11 |
espcOutputActiveActionsActions for the output active event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.12 |
espcOutputActiveTrapnumActions for the output active event.rw Integer32 .1.3.6.1.4.1.3052.20.2.2.6.1.13 |
espcOutputActiveClassClass (severity) for the output active event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.14 |
espcOutputInactiveAliasAlias for the output inactive state.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.20 |
espcOutputInactiveColorOutput color (as rendered in the web UI, in RGB hex format) corresponding to the output inactive state.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.21 |
espcOutputInactiveActionsActions for the output inactive event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.22 |
espcOutputInactiveTrapnumActions for the output inactive event.rw Integer32 .1.3.6.1.4.1.3052.20.2.2.6.1.23 |
espcOutputInactiveClassClass (severity) for the output inactive event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.2.6.1.24 |
serialPorts OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.3 |
numberPortsNumber of RS-232 ports found. Range: 2 or 4ro Integer32 .1.3.6.1.4.1.3052.20.2.3.1 |
portConfigTablePort config table SEQUENCE OF PortConfig .1.3.6.1.4.1.3052.20.2.3.2 |
portConfigEntryPort config entry PortConfig .1.3.6.1.4.1.3052.20.2.3.2.1 |
portConfigIndexIndex for portsro Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.1 |
portConfigBaudBaud rate, 19200, 9600, etc.rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.2 |
portConfigDataFormatValue representing word length, parity, and stop bits: 0=8N1, 1=7E1, 2=7O1, 3=7N1, 4=8O2rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.3 |
portConfigStripPtOutputLfsStrip passthrough LFs sent to device on this port: 1=yes, 0=no.rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.4 |
portConfigStripPtInputLfsStrip passthrough LFs received from device on this port: 1=yes, 0=no.rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.5 |
portConfigMaskEnable1=Use the character mask on this port. 0=Do not use the mask. When the mask is enabled, the following ASCII characters are ignored on the port: 0, 1, 4-9, 11, 12, 14-31, 128-255. When the mask is disabled, all characters are accepted on the port.rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.7 |
portConfigDAEnable1=Enable the Data Alarm Evaluator for data on this port. 0=Do not evaluate data on this port.rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.8 |
portConfigStoreAlarmsDPTON/OFF: store alarms received during passthroughrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.9 |
portConfigRecordTimeoutTimeout after last unterminated data received upon which data collected so far is stored as a record.rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.10 |
portConfigDataTypeHow the port interprets incoming data: ASCII/BINARYrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.11 |
portConfigEtxToCRLFON/OFF whether the port translates incoming ETX to CRLFrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.12 |
portConfigMLREnableON/OFF Whether Multiline Records are collected on this port.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.13 |
portConfigMLRStartField1PosPosition of MLR start field 1rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.14 |
portConfigMLRStartField1TextText to match MLR start field 1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.15 |
portConfigMLRStartField2PosPosition of MLR start field 2rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.16 |
portConfigMLRStartField2TextText to match MLR start field 2rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.17 |
portConfigMLRNumLinesBeforeNumber of lines before the starting line which should be included in the MLRrw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.18 |
portConfigMLREndDetectionHow the MLR parser determines what ends an MLR: by FORMULA, number of lines received so far (COUNT), or number of blank lines received so far (BLANKS)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.19 |
portConfigMLRLineCountNumber of lines in the MLR (used by the end detection mode)rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.20 |
portConfigMLREndField1PosPosition of MLR end field 1rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.21 |
portConfigMLREndField1TextText to match MLR end field 1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.22 |
portConfigMLREndField2PosPosition of MLR end field 2rw Integer32 .1.3.6.1.4.1.3052.20.2.3.2.1.23 |
portConfigMLREndField2TextText to match MLR end field 2rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.24 |
portConfigMLRUseComplexRulesON/OFF MLR parser uses complex rules (field possitions/ formulas, etc.)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.25 |
portConfigBufferPTON/OFF records received during passthrough mode are buffered/stored in the databaserw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.26 |
portConfigIdThe text identifer for the portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.27 |
portConfigModeMode of the serial port.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.28 |
portConfigHskHandshaking mode of the serial port.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.3.2.1.29 |
network OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4 |
interface OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1 |
ethernet OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1 |
ethernet1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.1 |
eth1ModeMode of the Ethernet1 interface: STATIC,DHCP,VLANro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.1.1 |
eth1AddressEthernet1 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.2 |
eth1SubnetMaskEthernet1 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.3 |
eth1RouterEthernet1 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.4 |
eth1VLAN OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.1.5 |
eth1VLAN1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.1 |
eth1VLAN1IDEthernet1 VLAN1 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.1.1 |
eth1VLAN1PriorityEthernet1 VLAN1 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.1.2 |
eth1VLAN1AddressEthernet1 VLAN1 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.1.3 |
eth1VLAN1SubnetMaskEthernet1 VLAN1 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.1.4 |
eth1VLAN1RouterEthernet1 VLAN1 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.1.5 |
eth1VLAN2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.2 |
eth1VLAN2IDEthernet1 VLAN2 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.2.1 |
eth1VLAN2PriorityEthernet1 VLAN2 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.2.2 |
eth1VLAN2AddressEthernet1 VLAN2 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.2.3 |
eth1VLAN2SubnetMaskEthernet1 VLAN2 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.2.4 |
eth1VLAN2RouterEthernet1 VLAN2 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.2.5 |
eth1VLAN3 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.3 |
eth1VLAN3IDEthernet1 VLAN3 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.3.1 |
eth1VLAN3PriorityEthernet1 VLAN3 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.3.2 |
eth1VLAN3AddressEthernet1 VLAN3 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.3.3 |
eth1VLAN3SubnetMaskEthernet1 VLAN3 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.3.4 |
eth1VLAN3RouterEthernet1 VLAN3 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.3.5 |
eth1VLAN4 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.4 |
eth1VLAN4IDEthernet1 VLAN4 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.4.1 |
eth1VLAN4PriorityEthernet1 VLAN4 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.4.2 |
eth1VLAN4AddressEthernet1 VLAN4 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.4.3 |
eth1VLAN4SubnetMaskEthernet1 VLAN4 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.4.4 |
eth1VLAN4RouterEthernet1 VLAN4 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.4.5 |
eth1VLAN5 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.5 |
eth1VLAN5IDEthernet1 VLAN5 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.5.1 |
eth1VLAN5PriorityEthernet1 VLAN5 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.5.2 |
eth1VLAN5AddressEthernet1 VLAN5 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.5.3 |
eth1VLAN5SubnetMaskEthernet1 VLAN5 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.5.4 |
eth1VLAN5RouterEthernet1 VLAN5 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.5.5 |
eth1VLAN6 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.6 |
eth1VLAN6IDEthernet1 VLAN6 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.6.1 |
eth1VLAN6PriorityEthernet1 VLAN6 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.6.2 |
eth1VLAN6AddressEthernet1 VLAN6 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.6.3 |
eth1VLAN6SubnetMaskEthernet1 VLAN6 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.6.4 |
eth1VLAN6RouterEthernet1 VLAN6 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.1.5.6.5 |
eth1MACEthernet1 MACro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.1.6 |
eth1IPv6 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.1.7 |
eth1IPv6ModeControls IPv6 operation for this Ethernet interface.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.1.7.1 |
eth1IPv6Static OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.1.7.2 |
eth1IPv6StaticAddresshe static IPv6 address to use for this interface when in operating in STATIC mode.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.1.7.2.1 |
eth1IPv6StaticRouterThe IPv6 router to engage as the default router when this interface operates in STATIC mode.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.1.7.2.2 |
eth1IPv6Auto OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.1.7.3 |
eth1IPv6AutoAddress1One of the automatically-acquired IPv6 addresses.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.1.7.3.1 |
eth1IPv6AutoAddress2One of the automatically-acquired IPv6 addresses.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.1.7.3.2 |
eth1IPv6AutoAddress3One of the automatically-acquired IPv6 addresses.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.1.7.3.3 |
eth1IPv6AutoAddress4One of the automatically-acquired IPv6 addresses.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.1.7.3.4 |
eth1IPv6LinkLocalAddressThe link local IPv6 address for this interface. This is present when the IPv6 mode is not OFF.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.1.7.4 |
ethernet2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.2 |
eth2ModeMode of the Ethernet2 interface: STATIC,DHCP,VLANro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.2.1 |
eth2AddressEthernet2 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.2 |
eth2SubnetMaskEthernet2 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.3 |
eth2RouterEthernet2 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.4 |
eth2VLAN OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.2.5 |
eth2VLAN1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.1 |
eth2VLAN1IDEthernet2 VLAN1 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.1.1 |
eth2VLAN1PriorityEthernet2 VLAN1 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.1.2 |
eth2VLAN1AddressEthernet2 VLAN1 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.1.3 |
eth2VLAN1SubnetMaskEthernet2 VLAN1 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.1.4 |
eth2VLAN1RouterEthernet2 VLAN1 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.1.5 |
eth2VLAN2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.2 |
eth2VLAN2IDEthernet2 VLAN2 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.2.1 |
eth2VLAN2PriorityEthernet2 VLAN2 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.2.2 |
eth2VLAN2AddressEthernet2 VLAN2 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.2.3 |
eth2VLAN2SubnetMaskEthernet2 VLAN2 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.2.4 |
eth2VLAN2RouterEthernet2 VLAN2 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.2.5 |
eth2VLAN3 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.3 |
eth2VLAN3IDEthernet2 VLAN3 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.3.1 |
eth2VLAN3PriorityEthernet2 VLAN3 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.3.2 |
eth2VLAN3AddressEthernet2 VLAN3 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.3.3 |
eth2VLAN3SubnetMaskEthernet2 VLAN3 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.3.4 |
eth2VLAN3RouterEthernet2 VLAN3 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.3.5 |
eth2VLAN4 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.4 |
eth2VLAN4IDEthernet2 VLAN4 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.4.1 |
eth2VLAN4PriorityEthernet2 VLAN4 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.4.2 |
eth2VLAN4AddressEthernet2 VLAN4 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.4.3 |
eth2VLAN4SubnetMaskEthernet2 VLAN4 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.4.4 |
eth2VLAN4RouterEthernet2 VLAN4 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.4.5 |
eth2VLAN5 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.5 |
eth2VLAN5IDEthernet2 VLAN5 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.5.1 |
eth2VLAN5PriorityEthernet2 VLAN5 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.5.2 |
eth2VLAN5AddressEthernet2 VLAN5 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.5.3 |
eth2VLAN5SubnetMaskEthernet2 VLAN5 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.5.4 |
eth2VLAN5RouterEthernet2 VLAN5 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.5.5 |
eth2VLAN6 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.6 |
eth2VLAN6IDEthernet2 VLAN6 IDrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.6.1 |
eth2VLAN6PriorityEthernet2 VLAN6 priorityrw Integer32 .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.6.2 |
eth2VLAN6AddressEthernet2 VLAN6 IP addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.6.3 |
eth2VLAN6SubnetMaskEthernet2 VLAN6 subnet maskrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.6.4 |
eth2VLAN6RouterEthernet2 VLAN6 routerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.1.1.2.5.6.5 |
eth2MACEthernet2 MACro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.2.6 |
eth2IPv6 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.2.7 |
eth2IPv6ModeControls IPv6 operation for this Ethernet interface.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.2.7.1 |
eth2IPv6Static OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.2.7.2 |
eth2IPv6StaticAddresshe static IPv6 address to use for this interface when in operating in STATIC mode.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.2.7.2.1 |
eth2IPv6StaticRouterThe IPv6 router to engage as the default router when this interface operates in STATIC mode.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.2.7.2.2 |
eth2IPv6Auto OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.1.1.2.7.3 |
eth2IPv6AutoAddress1One of the automatically-acquired IPv6 addresses.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.2.7.3.1 |
eth2IPv6AutoAddress2One of the automatically-acquired IPv6 addresses.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.2.7.3.2 |
eth2IPv6AutoAddress3One of the automatically-acquired IPv6 addresses.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.2.7.3.3 |
eth2IPv6AutoAddress4One of the automatically-acquired IPv6 addresses.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.2.7.3.4 |
eth2IPv6LinkLocalAddressThe link local IPv6 address for this interface. This is present when the IPv6 mode is not OFF.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.1.1.2.7.4 |
defaultRouterThe default router/gatewayrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.2 |
dnsTableDNS server address table SEQUENCE OF DNSConfig .1.3.6.1.4.1.3052.20.2.4.3 |
dnsEntryDNS server address entry DNSConfig .1.3.6.1.4.1.3052.20.2.4.3.1 |
dnsIndexIndex for DNS server addressro Integer32 .1.3.6.1.4.1.3052.20.2.4.3.1.1 |
dnsAddressDNS server addressrw IpAddress .1.3.6.1.4.1.3052.20.2.4.3.1.2 |
hostnameThe hostname of the unitrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.4 |
hostTableStatic host table SEQUENCE OF HostConfig .1.3.6.1.4.1.3052.20.2.4.5 |
hostEntryStatic host entry HostConfig .1.3.6.1.4.1.3052.20.2.4.5.1 |
hostIndexIndex for static hostro Integer32 .1.3.6.1.4.1.3052.20.2.4.5.1.1 |
hostDeclarationStatic host declaration string (i.e. 'address hostname')rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.5.1.2 |
ncpDuplexFor network command processor: 1=Input characters are echoed; 0=no echo.rw Integer32 .1.3.6.1.4.1.3052.20.2.4.6 |
ncpTimeoutNetwork command processor inactivity timeoutrw Integer32 .1.3.6.1.4.1.3052.20.2.4.7 |
snmp OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.8 |
snmpAgentEnableON/OFF for snmp agentrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.1 |
snmpNotificationCaptureEnableON/OFF unit receives and stores SNMP traps/informsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.5 |
snmpNotificationCaptureFileFile to which unit stores received SNMP traps/informsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.6 |
snmpNotificationTx OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.8.7 |
snmpNtfnAttemptsMaximum of times the unit attempts to send a notification (trap/inform) in 1 cyclerw Integer32 .1.3.6.1.4.1.3052.20.2.4.8.7.1 |
snmpNtfnTimeoutNumber of seconds between retries of sending a notificationrw Integer32 .1.3.6.1.4.1.3052.20.2.4.8.7.2 |
snmpNtfnCyclesNumber of times the unit attempts a group of attempts to send a notification (a cycle)rw Integer32 .1.3.6.1.4.1.3052.20.2.4.8.7.3 |
snmpNtfnSnoozeMinutes between cyclesrw Integer32 .1.3.6.1.4.1.3052.20.2.4.8.7.4 |
snmpPoll OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.8.9 |
snmpPModeMode of poll operation: OFF, POLL ONLY (just make the results available to view), or POLL BUFFER (store the results).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.1 |
snmpPBufferFileCRDB file in which data is stored.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.2 |
snmpPBufferAllPeriodPeriod (in seconds) that, if non-zero, all results are buffered in the CRDB regardless of the threshold.rw Integer32 .1.3.6.1.4.1.3052.20.2.4.8.9.3 |
snmpPRequestTableTable of SNMP Poll requests. SEQUENCE OF SNMPPollRequestConfig .1.3.6.1.4.1.3052.20.2.4.8.9.4 |
snmpPRequestEntryEntry for table pf SNMP Poll requests. SNMPPollRequestConfig .1.3.6.1.4.1.3052.20.2.4.8.9.4.1 |
snmpPRequestIndexIndex for table of SNMP Poll requests.ro Integer32 .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.1 |
snmpPRequestDescriptionA description for this single telemetry request; no functional effect.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.2 |
snmpPRequestAgentSNMP Agent IP address or hostname for this single telemetry request.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.3 |
snmpPRequestReadcomSNMP read community for this single telemetry request.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.4 |
snmpPRequestOIDSNMP object identifier for this single telemetry request.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.5 |
snmpPRequestPeriodHow many seconds between periodic SNMP polls of this single telemetry request.rw Integer32 .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.6 |
snmpPRequestIDA textual field that is part of the record containing the telemetry result.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.7 |
snmpPRequestThresholdControls when new data is stored upon a successful telemetry request.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.8 |
snmpPRequestResultStatusStatus of the last attempt for this telemetry request.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.10 |
snmpPRequestResultValueThe telemetry value if the last request was successful.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.11 |
snmpPRequestResultTimeThe timestamp of the last telemetry request.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.12 |
snmpPRequestResultTypeThe type of the telemetry as reported by the agent.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.8.9.4.1.13 |
ftpPush OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.9 |
ftpPushEnableEnable FTP push for REGULAR (protocol: FTP) or SECURE (protocol: SFTP) operation, or disable it (OFF)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.1 |
ftpPushServerFTP server to which data should be pushedrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.2 |
ftpPushAccountFTP push accountrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.5 |
ftpPushDirectoryFTP push directoryrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.6 |
ftpPushperiodMinutes between pushesrw Integer32 .1.3.6.1.4.1.3052.20.2.4.9.7 |
ftpPushPushFileTableTable of files to push SEQUENCE OF FTPPushPushFileConfig .1.3.6.1.4.1.3052.20.2.4.9.8 |
ftpPushPushFileEntryEntry for table of files to push FTPPushPushFileConfig .1.3.6.1.4.1.3052.20.2.4.9.8.1 |
ftpPushPushFileIndexIndex for table of files to pushro Integer32 .1.3.6.1.4.1.3052.20.2.4.9.8.1.1 |
ftpPushPushFileON/OFF push this local FILExrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.8.1.2 |
ftpPushPushAuditON/OFF push the audit logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.9 |
ftpPushPushAlarmsON/OFF push the alarms/events filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.10 |
ftpPushRemoteFileTableTable of remote names of files to push SEQUENCE OF FTPPushRemoteFileConfig .1.3.6.1.4.1.3052.20.2.4.9.11 |
ftpPushRemoteFileEntryEntry for table of remote names of files to push FTPPushRemoteFileConfig .1.3.6.1.4.1.3052.20.2.4.9.11.1 |
ftpPushRemoteFileIndexIndex for table of remote names of files to pushro Integer32 .1.3.6.1.4.1.3052.20.2.4.9.11.1.1 |
ftpPushRemoteFileNameremote name of pushed FILEx (name on server)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.11.1.2 |
ftpPushRemoteAlarmNameFilename on server for alarmsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.12 |
ftpPushPassiveON/OFF use ftp passive moderw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.13 |
ftpPushIncludeDateON/OFF include the date in the name of the pushed filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.14 |
ftpPushIncludeTimeON/OFF include the time in the name of the pushed filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.15 |
ftpPushIncludeSeqON/OFF include a sequence number in the name of the pushed filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.16 |
ftpPushPermissionsUnix permissions to apply to pushed files (octal notation).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.9.17 |
ppp OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.10 |
pppDial OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.10.1 |
pppDialEnableON/OFF PPP dialout enabledrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.10.1.1 |
pppDialNumberphone number to dialrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.10.1.2 |
pppDialIdleTimeoutSeconds of inactivity after which the unit disconnectsrw Integer32 .1.3.6.1.4.1.3052.20.2.4.10.1.5 |
pppDialRetriesNumber of dialing retries for PPPrw Integer32 .1.3.6.1.4.1.3052.20.2.4.10.1.6 |
pppDialCDTimeoutNumber of seconds to wait after dialing for CD before giving uprw Integer32 .1.3.6.1.4.1.3052.20.2.4.10.1.7 |
pppDialLoginTimeoutSeconds to wait to negotiate PPP after connectingrw Integer32 .1.3.6.1.4.1.3052.20.2.4.10.1.8 |
pppDialMdmInitModem init string to use when dialing PPPrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.10.1.9 |
pppDialSuggestIPIP address to suggest as the unit's end (local end) of the PPP linkrw IpAddress .1.3.6.1.4.1.3052.20.2.4.10.1.10 |
pppDialPlainLoginON/OFF look for login/password prompt before negotiating PPPrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.10.1.11 |
pppHost OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.10.2 |
pppHostEnableON/OFF Unit accepts PPP negotiationrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.10.2.1 |
pppHostIdleTimeoutSeconds of inactivity after which PPP-hosted link will terminaterw Integer32 .1.3.6.1.4.1.3052.20.2.4.10.2.2 |
pppHostLocalIPLocal IP address to negotiaterw IpAddress .1.3.6.1.4.1.3052.20.2.4.10.2.3 |
pppHostRemoteIPRemote IP address to hand out to PPP peerrw IpAddress .1.3.6.1.4.1.3052.20.2.4.10.2.4 |
routing OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.11 |
pppRoutingEnableON/OFF unit routes IP traffic from PPP/Wireless to Ethernetrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.11.1 |
ethRoutingEnableON/OFF unit routes IP traffic from Ethernet to PPP/Wirelessrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.11.2 |
ethRoutingNATEnableON/OFF unit applies NAT on routed IP frames egressing the unit on its PPP interfacerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.11.3 |
routingInterfaceWhen Ethernet routing is enabled (routing.1), this is the Ethernet interface to which IP frames received on PPP are routedrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.11.4 |
eth2WanRoutingEnableMake ETH2 operate as a WAN port to route outbound traffic arriving on ETH1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.11.5 |
netSecurity OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.12 |
ipRestriction OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.12.1 |
ipRestrictionTableTable of IP restrictions SEQUENCE OF IPRestrictionConfig .1.3.6.1.4.1.3052.20.2.4.12.1.1 |
ipRestrictionEntryEntry for table of IP restrictions IPRestrictionConfig .1.3.6.1.4.1.3052.20.2.4.12.1.1.1 |
ipRestrictionIndexIndex for table of IP restrictionsro Integer32 .1.3.6.1.4.1.3052.20.2.4.12.1.1.1.1 |
ipRestrictionEnableON/OFF enable this IP restrictionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.12.1.1.1.2 |
ipRestrictionMaskIP restriction maskrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.12.1.1.1.3 |
rts OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.13 |
rtsFileTableTable of RTS files SEQUENCE OF RTSFileConfig .1.3.6.1.4.1.3052.20.2.4.13.1 |
rtsFileEntryEntry for table of RTS files RTSFileConfig .1.3.6.1.4.1.3052.20.2.4.13.1.1 |
rtsFileIndexIndex for table of RTS filesro Integer32 .1.3.6.1.4.1.3052.20.2.4.13.1.1.1 |
rtsFileModeRTS mode (OFF,LISTEN,PUSH) for FILExrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.13.1.1.2 |
rtsFileShowAnswerShow answer string upon RTS connect for FILExrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.13.1.1.3 |
rtsFileReqXONON/OFF require XON to start flow for FILExrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.13.1.1.4 |
rtsFileTimeoutIdle connection close timer (0 means no timeout) for FILExrw Integer32 .1.3.6.1.4.1.3052.20.2.4.13.1.1.5 |
rtsFileEmptyCloseON/OFF close the socket when FILEx is emptyrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.13.1.1.6 |
rtsFilePushHostHost to which FILEx should be pushed via RTSrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.13.1.1.7 |
rtsFilePushPortTCP port to which FILEx should be pushed via RTSrw Integer32 .1.3.6.1.4.1.3052.20.2.4.13.1.1.8 |
rtsFilePushRetryTimerRetry timer (seconds) for retrying failed RTS push connect attemptsrw Integer32 .1.3.6.1.4.1.3052.20.2.4.13.1.1.9 |
rtsAlarms OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.13.2 |
rtsAlarmsModeRTS mode (OFF,LISTEN,PUSH) for alarms filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.13.2.1 |
rtsAlarmsShowAnswerShow answer string upon RTS connect for alarms filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.13.2.2 |
rtsAlarmsReqXONON/OFF require XON to start flow for alarms filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.13.2.3 |
rtsAlarmsTimeoutIdle connection close timer (0 means no timeout) for alarms filerw Integer32 .1.3.6.1.4.1.3052.20.2.4.13.2.4 |
rtsAlarmsEmptyCloseON/OFF close the socket when this file is empty for alarms filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.13.2.5 |
rtsAlarmsPushHostHost to which alarms file should be pushed via RTSrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.13.2.6 |
rtsAlarmsPushPortTCP port to which alarms file should be pushed via RTSrw Integer32 .1.3.6.1.4.1.3052.20.2.4.13.2.7 |
rtsAlarmsPushRetryTimerRetry timer (seconds) for retrying failed RTS push connect attemptsrw Integer32 .1.3.6.1.4.1.3052.20.2.4.13.2.8 |
trap OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.14 |
trapInclude OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.14.1 |
trapIncludeDateTimeON/OFF include date and time in stock trap messagerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.14.1.1 |
trapIncludeSiteNameON/OFF include site name in stock trap messagerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.14.1.2 |
trapIncludeSensorIDON/OFF include sensor ID in stock trap messagerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.14.1.3 |
trapIncludeUDNameON/OFF include user defined name in stock trap messagerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.14.1.4 |
trapIncludeUDStateON/OFF include user defined state in stock trap messagerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.14.1.5 |
trapIncludeSourceAddressON/OFF include source IP address in stock trap messagerw IpAddress .1.3.6.1.4.1.3052.20.2.4.14.1.6 |
trapAuthFailEnableON/OFF enable trap sent upon SNMP authentication failurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.14.2 |
routeTest OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.15 |
routeTestEnableON/OFF enable route testingrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.15.1 |
routeTestPeriodThe period which a route is considered validrw Integer32 .1.3.6.1.4.1.3052.20.2.4.15.2 |
routeTestAddressTableTable of route testing addresses SEQUENCE OF RouteTestConfig .1.3.6.1.4.1.3052.20.2.4.15.3 |
routeTestAddressEntryEntry for table of RTS files RouteTestConfig .1.3.6.1.4.1.3052.20.2.4.15.3.1 |
routeTestAddressIndexIndex for table of RTS filesro Integer32 .1.3.6.1.4.1.3052.20.2.4.15.3.1.1 |
routeTestAddressAddress to ping to see if the route to it is validrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.15.3.1.2 |
wireless OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.16 |
wirelessModeWireless mode (OFF,PERMANENT-EDGE)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.16.1 |
wirelessAPNWireless access point namerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.16.2 |
wirelessIdleTimeoutWireless idle timeoutrw Integer32 .1.3.6.1.4.1.3052.20.2.4.16.3 |
wirelessPINWireless modem SIM PINrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.16.5 |
wirelessDREDefault route enable for wireless network interface. When this is ON, the wireless link, if up, becomes the default route, overriding the default route setting (defaultRouter object). When OFF, the default route setting controls the default route and the wireless link does not become the default route.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.16.9 |
wirelessPPPUsernameUsername for PPP-based wireless modem connections.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.16.10 |
wirelessFirewallEnable wireless modem firewall.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.16.11 |
wirelessKeepaliveThresholdMinutes of no RX activity before sending keep-alive.rw Integer32 .1.3.6.1.4.1.3052.20.2.4.16.12 |
wirelessPPPDebugEnable wireless modem PPP debug.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.16.13 |
wirelessConnectivity OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.16.20 |
wirelessConnEnableEnable wireless modem connectivity check.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.16.20.1 |
wirelessConnCheckIntervalWireless connectivity check interval in minutes.rw Integer32 .1.3.6.1.4.1.3052.20.2.4.16.20.2 |
wirelessConnFailThresholdWireless connectivity fail threshold.rw Integer32 .1.3.6.1.4.1.3052.20.2.4.16.20.3 |
wirelessConnIP1Wireless connectivity check IP address 1.rw IpAddress .1.3.6.1.4.1.3052.20.2.4.16.20.10 |
wirelessConnIP2Wireless connectivity check IP address 2.rw IpAddress .1.3.6.1.4.1.3052.20.2.4.16.20.11 |
email OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.17 |
emailServerSMTP server to which the unit sends emailrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.17.1 |
emailDomainDomain to use in recipient addressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.17.2 |
emailAuthEnableON/OFF enable SMTP authenticationrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.17.3 |
netAdvanced OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.18 |
arpFilterARP filter coderw Integer32 .1.3.6.1.4.1.3052.20.2.4.18.1 |
web OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.19 |
webEnableON/OFF for the web interfacerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.19.1 |
webPortTCP port on which web interface listensrw Integer32 .1.3.6.1.4.1.3052.20.2.4.19.2 |
webTimeoutWeb interface session timeout (seconds)rw Integer32 .1.3.6.1.4.1.3052.20.2.4.19.3 |
ipv6 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.21 |
ipv6DefaultRouterThe IPv6 default router in use.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.21.1 |
cpe OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.4.22 |
cpeTableTable of CPEs SEQUENCE OF CPEConfig .1.3.6.1.4.1.3052.20.2.4.22.1 |
cpeEntryEntry for table of CPEs CPEConfig .1.3.6.1.4.1.3052.20.2.4.22.1.1 |
cpeIndexIndex for table of CPEsro Integer32 .1.3.6.1.4.1.3052.20.2.4.22.1.1.1 |
cpeHostCPE host (IP address or DNS name)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.22.1.1.2 |
cpeNameCPE name, informational onlyrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.22.1.1.3 |
cpeDescriptionCPE description, informational onlyrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.22.1.1.4 |
cpeKeepaliveNumber of seconds between each successful ping request.rw Integer32 .1.3.6.1.4.1.3052.20.2.4.22.1.1.5 |
cpeThresholdNumber of unsuccessful pings that triggers the CPE event.rw Integer32 .1.3.6.1.4.1.3052.20.2.4.22.1.1.6 |
cpeEventReminderIntervalCPE event reminder interval (minutes).rw Integer32 .1.3.6.1.4.1.3052.20.2.4.22.1.1.7 |
cpeKeepaliveTicksCPE ping period in 16ths of a second (nonzero overrides keepalive).rw Integer32 .1.3.6.1.4.1.3052.20.2.4.22.1.1.20 |
cpePingSizeNumber of bytes in CPE ping payloadrw Integer32 .1.3.6.1.4.1.3052.20.2.4.22.1.1.21 |
cpeInfoResetSet any number to reset CPE ping stats.ro Integer32 .1.3.6.1.4.1.3052.20.2.4.22.1.1.30 |
cpeInfoNumReqTotal number of requests transmitted.ro Integer32 .1.3.6.1.4.1.3052.20.2.4.22.1.1.31 |
cpeInfoNumGoodRespTotal number of non-corrupt responses.ro Integer32 .1.3.6.1.4.1.3052.20.2.4.22.1.1.32 |
cpeInfoNumBadRespTotal number of corrupt responses.ro Integer32 .1.3.6.1.4.1.3052.20.2.4.22.1.1.33 |
cpeInfoNumLostRespTotal number of requests with no response.ro Integer32 .1.3.6.1.4.1.3052.20.2.4.22.1.1.34 |
cpeInfoPercentLossPercent loss (missing responses / total requests).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.22.1.1.35 |
cpeInfoPercentBadPercent corrupt (corrupt responses / total requests).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.4.22.1.1.36 |
modem OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.5 |
modemFormatModem data format (8N1,7E1,7O1,7N1)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.5.1 |
modemInitStringInit string for modemrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.5.2 |
modemCallAttemptsMax mumber of times the modem should try to call out until successful connectrw Integer32 .1.3.6.1.4.1.3052.20.2.5.4 |
modemCallDelayMinimum delay (seconds) between calloutsrw Integer32 .1.3.6.1.4.1.3052.20.2.5.5 |
modemCmdTimoutNumber of minutes after which an idle command session via modem is terminatedrw Integer32 .1.3.6.1.4.1.3052.20.2.5.6 |
modemGotoWhen a user connects, where that user is routed (command session, passthrough to port 1, passthrough to port 2, etc.)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.5.7 |
modemClid OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.5.8 |
modemCLIDEnableON/OFF Calling Line Identification securityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.5.8.1 |
modemCLIDNumberTableTable of authorized callers identified by phone number SEQUENCE OF ModemCLIDNumberConfig .1.3.6.1.4.1.3052.20.2.5.8.2 |
modemCLIDNumberEntryEntry for table of CLID numbers ModemCLIDNumberConfig .1.3.6.1.4.1.3052.20.2.5.8.2.1 |
modemCLIDNumberIndexIndex for table of CLID numbersro Integer32 .1.3.6.1.4.1.3052.20.2.5.8.2.1.1 |
modemCLIDNumberauhorized CLID numberrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.5.8.2.1.2 |
modemTAPInitStringInit string to use for TAP (pager) connectionsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.5.9 |
modemTAP8N1ON/OFF: use 8N1 data/parity/stop for TAP connectionsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.5.10 |
time OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.8 |
clockText string for date and time; e.g. 'SUN 01/02/98 12:34:27'. When setting this object, only the date and time are required; the unit will ignore a specified day of week because it is calculated from the date and time. When this object is included in a notification as a varbind, it represents the time that the triggering event occurred.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.8.1 |
console OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.10 |
consoleDuplexON/OFF characters echoed on telnet command sessionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.10.1 |
consoleTimeoutMinutes of inactivity after which telnet command session is terminatedrw Integer32 .1.3.6.1.4.1.3052.20.2.10.2 |
consoleBaudConsole baud raterw Integer32 .1.3.6.1.4.1.3052.20.2.10.4 |
consoleFormatConsole data format (8N1,7E1,7O1,7N1,8O2)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.10.5 |
consoleHskConsole handshaking moderw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.10.6 |
consoleConfirmON/OFF Prompt to confirm certain actionsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.10.7 |
unitSecurity OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.11 |
secCore OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.11.1 |
scShowPasswordPromptON/OFF show password prompt upon loginrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.1.1 |
scConsoleLoginRequiredON/OFF login required upon connecting via consolerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.1.2 |
scModemLoginRequiredON/OFF login required upon connecting via modemrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.1.3 |
scTelnetLoginRequiredON/OFF login required upon connecting via Telnetrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.1.4 |
scTelnetPTLoginRequiredON/OFF login required upon connecting via Telnet to pass- through ports (TCP ports 210x)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.1.5 |
scRTSLoginRequiredON/OFF login required upon connecting to RTS (TCP ports 220x)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.1.6 |
scAuthModeAuthentication mode (USERNAME/PW,PW/USERNAME,PASSWORD ONLY)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.1.7 |
scRightsGroupThe set of aliases used for the 8 available rights levelsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.1.8 |
scSecretShared secret for challengesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.1.9 |
secUserTableTable of users SEQUENCE OF SecUserConfig .1.3.6.1.4.1.3052.20.2.11.2 |
secUserEntryEntry for table of users SecUserConfig .1.3.6.1.4.1.3052.20.2.11.2.1 |
secUserIndexIndex for table of usersro Integer32 .1.3.6.1.4.1.3052.20.2.11.2.1.1 |
secUserEnableON/OFF enable userrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.2 |
secUserConnectViaMethods by which user is allowed to connect: L=local (console) T=Telnet M=modem F=FTP R=RTS S=SSHrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.5 |
secUserLoginToThe function presented to the user upon login (COMMAND, PASSTHROUGH,MENU)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.6 |
secUserAccessFileThe default access file associated with the userrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.7 |
secUserPTEscapeToThe function presented to the user upon escaping pass- through: currently only MENUrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.9 |
secUserPPPTypeThe kind of PPP access allowed to this user cannot connect via PPP (NONE), can connect but only to the unit (LOCAL), or can connect and route to Ethernet (ROUTING)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.10 |
secUserRightsThe rights level granted to this userrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.11 |
secUserEventsReadAccessDENY/ALLOW user to read the events/alarms filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.13 |
secUserAuditReadAccessDENY/ALLOW user to read the audit logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.14 |
secUserEventsWriteAccessDENY/ALLOW user to delete the events filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.16 |
secUserAuditWriteAccessDENY/ALLOW user to write to the audit logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.17 |
secUserExpirationExpiration date/time of this userrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.18 |
secUserCallbackNumber1Number slot 1 the unit calls for dialbackrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.19 |
secUserCallbackNumber2Number slot 2 the unit calls for dialbackrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.20 |
secUserCallbackNumber3Number slot 3 the unit calls for dialbackrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.21 |
secUserChallengeTelnetModeTelnet challenge mode: when user logs in via telnet, unit allows access (OFF), presents a challenge (CHALLENGE), or unit sends a one-time-password (SEND PASSWORD) to a destination configured by secUserChallengeTelnetSendTorw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.22 |
secUserChallengeModemModeModem challenge mode: when user logs in via modem, unit allows access (OFF), presents a challenge (CHALLENGE), sends a one-time-password (SEND PASSWORD) to a destination configured by secUserChallengeTelnetSendTo, or dials a number (CALLBACK) configured with secUserCallbackNumberxrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.23 |
secUserChallengeConsoleModeConsole challenge mode: when user logs in via console, unit allows access (OFF), or presents a challenge (CHALLENGE)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.24 |
secUserChallengeTelnetSendToEmail action used as the destination address for one-time- password when a user logs in with a challenge mode of SEND PASSWORDrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.25 |
secUserChallengeModemSendToModem action used as the destination phone number for one- time-password when a user logs in with a challenge mode of SEND PASSWORDrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.2.1.26 |
secUserChallengeExpirationTime (in minutes) after which a one-time-password is sent that it can be used to log inrw Integer32 .1.3.6.1.4.1.3052.20.2.11.2.1.27 |
secFactory OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.11.3 |
sfEnableON/OFF enable factory accessrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.3.1 |
sfSecretSecret used for factory accessrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.11.3.2 |
secSSH OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.11.4 |
secVPN OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.11.5 |
event OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12 |
evCore OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.1 |
evClassNameTableTable of classes SEQUENCE OF EventClassConfig .1.3.6.1.4.1.3052.20.2.12.1.1 |
evClassNameEntryEntry for table of classes EventClassConfig .1.3.6.1.4.1.3052.20.2.12.1.1.1 |
evClassNameIndexIndex for table of classesro Integer32 .1.3.6.1.4.1.3052.20.2.12.1.1.1.1 |
evClassNameClass name for this slotrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.1.1.1.2 |
evReminderIntervalInterval (minutes) between EventSensor reminder eventsrw Integer32 .1.3.6.1.4.1.3052.20.2.12.1.2 |
evLog OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.1.3 |
evLogEnableON/OFF enable event logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.1.3.1 |
evLogStoreAlarmON/OFF store data alarms in event logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.1.3.2 |
evLogMaxSizemax size (in KB) of event logrw Integer32 .1.3.6.1.4.1.3052.20.2.12.1.3.3 |
evLogStoreSensorON/OFF store EventSensor events in event logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.1.3.4 |
evLogTimeStampAlarmsON/OFF put timestamps on event log entriesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.1.3.5 |
evLogPrependNameON/OFF prepend data event name to data alarm records in event logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.1.3.6 |
evMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.1.4 |
evMgmtReprocessNumber of sensors that have generated events since reset. Write this to reprocess each sensor's last generated event since reset. The value to write determines what kind of events should be reprocessed: 'all': all sensor events 'cc': cc events 'temperature': temperature events 'humidity': humidity events 'analog': analog input eventsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.1.4.3 |
evData OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.2 |
evdCore OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.2.1 |
evdExitOnTrueON/OFF: Data alarm evaluator stops checking record against alarm equations when it finds an equation that matchesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.1.1 |
evdFilterActionWhat happens to a record that matches an equation: REJECT/ACCEPTrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.1.2 |
evdWildCardCharCharacter (in decimal ASCII code format) used to indicate wildcards in data alarm equationrw Integer32 .1.3.6.1.4.1.3052.20.2.12.2.1.3 |
evdTableTable of data events SEQUENCE OF DataEventConfig .1.3.6.1.4.1.3052.20.2.12.2.2 |
evdEntryEntry for table of data events DataEventConfig .1.3.6.1.4.1.3052.20.2.12.2.2.1 |
evdIndexIndex for table of data eventsro Integer32 .1.3.6.1.4.1.3052.20.2.12.2.2.1.1 |
evdEnableON/OFF enable this data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.2.1.2 |
evdNameName for this data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.2.1.3 |
evdEquationEquation for this data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.2.1.4 |
evdThresholdNumber of equation matches that must happen to trigger this data eventrw Integer32 .1.3.6.1.4.1.3052.20.2.12.2.2.1.5 |
evdAutoClearON/OFF this data alarm is automatically cleared (re-armed) upon reaching the threshold number of matchesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.2.1.6 |
evdClearIntervalInterval at which this alarm is automatically cleared (no bearing with evdAutoClear)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.2.1.7 |
evdClearTimeTie of day (HH:MM) at which this data alarm is cleared (no bearing with evdAutoClear)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.2.1.8 |
evdActionsActions for this data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.2.1.9 |
evdClassClass for this data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.2.1.10 |
evdTrapNumTrap number for this eventrw Integer32 .1.3.6.1.4.1.3052.20.2.12.2.2.1.11 |
evdModeALARM/FILTER: what is happens when this data event triggers: either generate actions (mode=ALARM) )or ACCEPT/REJECT (via evdFilterAction) the record (mode=FILTER)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.2.1.12 |
evdFieldTableTable of data event fields SEQUENCE OF DataEventFieldConfig .1.3.6.1.4.1.3052.20.2.12.2.3 |
evdFieldEntryEntry for table of data event fields DataEventFieldConfig .1.3.6.1.4.1.3052.20.2.12.2.3.1 |
evdFieldIndexIndex for table of data event fieldsro Integer32 .1.3.6.1.4.1.3052.20.2.12.2.3.1.1 |
evdFieldStartStart position (1-based) for this data event fieldrw Integer32 .1.3.6.1.4.1.3052.20.2.12.2.3.1.2 |
evdFieldLengthNumber of characters this data event field occupiesrw Integer32 .1.3.6.1.4.1.3052.20.2.12.2.3.1.3 |
evdFieldNameStart position (1-based) for this data event fieldrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.3.1.4 |
evdFieldLineLine number (1-based, for multiline records) for this data event fieldrw Integer32 .1.3.6.1.4.1.3052.20.2.12.2.3.1.5 |
evdFieldTypeAlpha/Numeric type for this data event fieldrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.3.1.6 |
evdMacroTableTable of data event macros SEQUENCE OF DataEventMacroConfig .1.3.6.1.4.1.3052.20.2.12.2.4 |
evdMacroEntryEntry for table of data event macros DataEventMacroConfig .1.3.6.1.4.1.3052.20.2.12.2.4.1 |
evdMacroIndexIndex for table of data event macrosro Integer32 .1.3.6.1.4.1.3052.20.2.12.2.4.1.1 |
evdMacroNameName of this macro for use in data event equationsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.4.1.2 |
evdMacroEquationEquation for this data event macrorw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.2.4.1.3 |
evNoData1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.3 |
evNoData1EnableON/OFF enable this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.3.1 |
evNoData1ActionsActions for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.3.2 |
evNoData1MessageMessage for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.3.3 |
evNoData1TrapNumTrap number for this no data eventrw Integer32 .1.3.6.1.4.1.3052.20.2.12.3.4 |
evNoData1ClassClass for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.3.5 |
evNoData1Sched1BeginSchedule 1 begin time (HH:MM) for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.3.6 |
evNoData1Sched1EndSchedule 1 end time (HH:MM) for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.3.7 |
evNoData1Sched1DurationDuration (minutes) for schedule 1 of this no data eventrw Integer32 .1.3.6.1.4.1.3052.20.2.12.3.8 |
evNoData1Sched2BeginSchedule 2 begin time (HH:MM) for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.3.9 |
evNoData1Sched2EndSchedule 2 end time (HH:MM) for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.3.10 |
evNoData1Sched2DurationDuration (minutes) for schedule 2 of this no data eventrw Integer32 .1.3.6.1.4.1.3052.20.2.12.3.11 |
evNoData1PortEnableTableTable of no data event 1 port enables SEQUENCE OF NoDataEvent1PortEnableConfig .1.3.6.1.4.1.3052.20.2.12.3.12 |
evNoData1PortEnableEntryEntry for table of no data event 1 port enables NoDataEvent1PortEnableConfig .1.3.6.1.4.1.3052.20.2.12.3.12.1 |
evNoData1PortEnableIndexIndex for table of no data event 1 port enablesro Integer32 .1.3.6.1.4.1.3052.20.2.12.3.12.1.1 |
evNoData1PortEnableON/OFF: no data event 1 observes this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.3.12.1.2 |
evNoData1ExclusionsExclusions (space-separated MM/DD-formatted dates) for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.3.13 |
evNoData1DaysDays of the week on which this no event is activerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.3.14 |
evNoData2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.4 |
evNoData2EnableON/OFF enable this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.4.1 |
evNoData2ActionsActions for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.4.2 |
evNoData2MessageMessage for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.4.3 |
evNoData2TrapNumTrap number for this no data eventrw Integer32 .1.3.6.1.4.1.3052.20.2.12.4.4 |
evNoData2ClassClass for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.4.5 |
evNoData2Sched1BeginSchedule 1 begin time (HH:MM) for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.4.6 |
evNoData2Sched1EndSchedule 1 end time (HH:MM) for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.4.7 |
evNoData2Sched1DurationDuration (minutes) for schedule 1 of this no data eventrw Integer32 .1.3.6.1.4.1.3052.20.2.12.4.8 |
evNoData2Sched2BeginSchedule 2 begin time (HH:MM) for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.4.9 |
evNoData2Sched2EndSchedule 2 end time (HH:MM) for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.4.10 |
evNoData2Sched2DurationDuration (minutes) for schedule 2 of this no data eventrw Integer32 .1.3.6.1.4.1.3052.20.2.12.4.11 |
evNoData2PortEnableTableTable of no data event 2 port enables SEQUENCE OF NoDataEvent2PortEnableConfig .1.3.6.1.4.1.3052.20.2.12.4.12 |
evNoData2PortEnableEntryEntry for table of no data event 2 port enables NoDataEvent2PortEnableConfig .1.3.6.1.4.1.3052.20.2.12.4.12.1 |
evNoData2PortEnableIndexIndex for table of no data event 2 port enablesro Integer32 .1.3.6.1.4.1.3052.20.2.12.4.12.1.1 |
evNoData2PortEnableON/OFF: no data event 2 observes this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.4.12.1.2 |
evNoData2ExclusionsExclusions (space-separated MM/DD-formatted dates) for this no data eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.4.13 |
evNoData2DaysDays of the week on which this no event is activerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.4.14 |
evSched1 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.5 |
evSched1EnableON/OFF enable this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.1 |
evSched1ActionsActions for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.2 |
evSched1MessageMessage for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.3 |
evSched1TrapNumTrap number for this scheduled eventrw Integer32 .1.3.6.1.4.1.3052.20.2.12.5.4 |
evSched1ClassClass for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.5 |
evSched1SundayTime on Sunday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.6 |
evSched1MondayTime on Monday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.7 |
evSched1TuesdayTime on Tuesday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.8 |
evSched1WednesdayTime on Wednesday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.9 |
evSched1ThursdayTime on Thursday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.10 |
evSched1FridayTime on Friday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.11 |
evSched1SaturdayTime on Saturday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.12 |
evSched1ExclusionsExclusions (space-separated MM/DD-formatted dates) for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.5.13 |
evSched2 OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.6 |
evSched2EnableON/OFF enable this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.1 |
evSched2ActionsActions for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.2 |
evSched2MessageMessage for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.3 |
evSched2TrapNumTrap number for this scheduled eventrw Integer32 .1.3.6.1.4.1.3052.20.2.12.6.4 |
evSched2ClassClass for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.5 |
evSched2SundayTime on Sunday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.6 |
evSched2MondayTime on Monday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.7 |
evSched2TuesdayTime on Tuesday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.8 |
evSched2WednesdayTime on Wednesday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.9 |
evSched2ThursdayTime on Thursday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.10 |
evSched2FridayTime on Friday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.11 |
evSched2SaturdayTime on Saturday (HH:MM) when this scheduled event triggersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.12 |
evSched2ExclusionsExclusions (space-separated MM/DD-formatted dates) for this scheduled eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.6.13 |
evShskLowTableTable of serial handshaking low events SEQUENCE OF SerialHandshakingLowEventConfig .1.3.6.1.4.1.3052.20.2.12.7 |
evShskLowEntryEntry for table of serial handshaking low events SerialHandshakingLowEventConfig .1.3.6.1.4.1.3052.20.2.12.7.1 |
evShskLowIndexIndex for table of serial handshaking low eventsro Integer32 .1.3.6.1.4.1.3052.20.2.12.7.1.1 |
evShskLowEnableON/OFF: enable the serial handshaking low event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.7.1.2 |
evShskLowActionsActions for the serial handshaking low event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.7.1.3 |
evShskLowMessageMessage for the serial handshaking low event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.7.1.4 |
evShskLowClassClass for the serial handshaking low event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.7.1.5 |
evShskLowTrapNumTrap number for the serial handshaking low event for this portrw Integer32 .1.3.6.1.4.1.3052.20.2.12.7.1.6 |
evShskHighTableTable of serial handshaking high events SEQUENCE OF SerialHandshakingHighEventConfig .1.3.6.1.4.1.3052.20.2.12.8 |
evShskHighEntryEntry for table of serial handshaking high events SerialHandshakingHighEventConfig .1.3.6.1.4.1.3052.20.2.12.8.1 |
evShskHighIndexIndex for table of serial handshaking high eventsro Integer32 .1.3.6.1.4.1.3052.20.2.12.8.1.1 |
evShskHighEnableON/OFF: enable the serial handshaking high event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.8.1.2 |
evShskHighActionsActions for the serial handshaking high event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.8.1.3 |
evShskHighMessageMessage for the serial handshaking high event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.8.1.4 |
evShskHighClassClass for the serial handshaking high event for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.8.1.5 |
evShskHighTrapNumTrap number for the serial handshaking high event for this portrw Integer32 .1.3.6.1.4.1.3052.20.2.12.8.1.6 |
evNoSensor OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.9 |
evNoSensorTimeoutTimeout (seconds) after which an EventSensor becomes unresponsive that this event is triggeredrw Integer32 .1.3.6.1.4.1.3052.20.2.12.9.1 |
evNoSensorActionsActions for no sensor eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.9.2 |
evNoSensorTrapNumTrap number for no sensor eventrw Integer32 .1.3.6.1.4.1.3052.20.2.12.9.3 |
evNoSensorClassClass for no sensor eventrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.9.4 |
fuelSensor OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.11 |
fuelSensorGeneralTableThis table organizes general fuel sensor attributes. SEQUENCE OF FuelSensorConfigGeneral .1.3.6.1.4.1.3052.20.2.12.11.1 |
fsGenEntryEntry for fuel sensor general config table. FuelSensorConfigGeneral .1.3.6.1.4.1.3052.20.2.12.11.1.1 |
fsGenIndexWhich fuel sensor in the fuel sensor general config table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.11.1.1.1 |
fsGenNameFuel sensor name.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.1.1.2 |
fsGenSensorTypeType of fuel sensor in use; NONE disables the fuel sensor.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.1.1.3 |
fsGenDistanceUnitDistance units in use when setting and indicating tank dimensions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.1.1.4 |
fsGenRawValueTopAnalog input reading corresponding to the SENSOR FULL point.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.1.1.5 |
fsGenTopOffsetDistance, in the specified distance unit, between the SENSOR FULL point and the TANK FULL point. The value is positive if the SENSOR FULL point is above the TANK FULL point, and negative if it is below.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.1.1.6 |
fsGenRawValueBottomAnalog input reading corresponding to the minimum fluid height measurable by the fuel sensor.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.1.1.7 |
fsGenBottomOffsetDistance, in the specified distance unit, between the SENSOR EMPTY point and the TANK EMPTY point. The value is positive if the SENSOR EMPTY point is above the TANK EMPTY point, and negative if it is below.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.1.1.8 |
fsGenInputESWhich eventsensor contains the analog input associated with this fuel sensor. Allowed values are 200 (for internal ES), or 1-16.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.1.1.9 |
fsGenInputPointWhich analog input point, on the specified eventsensor, that is associated with the fuel sensor.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.1.1.10 |
fsGenFilterAveragingFuel sensor filter averaging factor.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.1.1.11 |
fsGenSysrepEnableFuel sensor System Reporting enable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.1.1.12 |
fsGenSysrepThresholdFuel sensor System Reporting threshold (floating point value).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.1.1.13 |
fsGenSysrepLimitFuel sensor System Reporting limit.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.1.1.14 |
fsGenSysrepPackageFuel sensor System Reporting package number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.1.1.15 |
fsGenSysrepTypeFuel sensor ASM profile type.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.1.1.16 |
fsGenEnableFuel sensor enable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.1.1.17 |
fuelSensorTankTableThis table organizes tank-specific fuel sensor attributes. SEQUENCE OF FuelSensorConfigTank .1.3.6.1.4.1.3052.20.2.12.11.2 |
fsTankEntryEntry for fuel sensor tank config table. FuelSensorConfigTank .1.3.6.1.4.1.3052.20.2.12.11.2.1 |
fsTankIndexWhich fuel sensor in the fuel sensor tank config table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.11.2.1.1 |
fsTankHeightHeight of the tank, from the TANK EMPTY point to the TANK FULL point, in the specified distance unit (i.e. TANK HEIGHT). This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.2.1.2 |
fsTankDimATank dimension measurement A for certain tank profiles. For HORIZ OVAL, this is the length of the straight section. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.2.1.3 |
fsTankDimBTank dimension measurement B for certain tank profiles. For HORIZ OVAL, this is the radius of the curved section. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.2.1.4 |
fsTankVolumeHow many volume units the tank contains, when full. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.2.1.5 |
fsTankVolumeUnitName of the unit representing fluid volume in the tank. This is only used for display purposes; it does not affect the volume calculation.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.2.1.6 |
fsTankShapeThe shape of the fuel tank. A value of LINEAR produces a fluid volume reading that is directly proportional to fluid height. The HORIZ CYL and HORIZ OVAL settings use a hard-coded formula to calculate the volume. The CUSTOM setting uses a strapping table that must be configured as well (see fuelSensorCustomTankTable).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.2.1.7 |
fuelSensorCustomTankTableThis table organizes the custom tank strapping table. Each fuel sensor has a table of height/volume pairs in service only when the tank shape (fsTankShape) in CUSTOM. This allows the unit to calculate volumes for nonstandard tank shapes, to the degree that accurate height/volume measurements can be configured. This SNMP table has two indexes: the first for which fuel sensor and the second for which height/volume pair. SEQUENCE OF FuelSensorConfigCustomTankStrapping .1.3.6.1.4.1.3052.20.2.12.11.3 |
fsCustomTankEntryEntry for fuel sensor custom tank config table. FuelSensorConfigCustomTankStrapping .1.3.6.1.4.1.3052.20.2.12.11.3.1 |
fsCustomTankIndexFSWhich fuel sensor in the fuel sensor tank config table. This is the first of two indexes for this SNMP table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.11.3.1.1 |
fsCustomTankIndexDatumWhich hight/volume pair: there are 32 pairs per fuel sensor. This is the second of two indexes for this SNMP table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.11.3.1.2 |
fsCustomTankHeightHeight of custom tank height/volume pair. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.3.1.3 |
fsCustomTankVolumeVolume of custom tank height/volume pair. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.3.1.4 |
fuelSensorVolumeTableThis table organizes volume-event-specific fuel sensor attributes. SEQUENCE OF FuelSensorConfigVolume .1.3.6.1.4.1.3052.20.2.12.11.4 |
fsVolumeEntryEntry for fuel sensor volume event config table. FuelSensorConfigVolume .1.3.6.1.4.1.3052.20.2.12.11.4.1 |
fsVolumeIndexWhich fuel sensor in the fuel sensor volume event config table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.11.4.1.1 |
fsVolumeEnableEnable fuel sensor volume events.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.2 |
fsVolumeDeadbandFuel sensor deadband (hysteresis). This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.3 |
fsVolumeVHighValueFuel sensor volume very high event threshold value. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.4 |
fsVolumeVHighActionsFuel sensor volume very high event threshold actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.5 |
fsVolumeVHighTrapNumFuel sensor volume very high event threshold trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.4.1.6 |
fsVolumeVHighClassFuel sensor volume very high event threshold class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.7 |
fsVolumeHighValueFuel sensor volume high event threshold value. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.8 |
fsVolumeHighActionsFuel sensor volume high event threshold actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.9 |
fsVolumeHighTrapNumFuel sensor volume high event threshold trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.4.1.10 |
fsVolumeHighClassFuel sensor volume high event threshold class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.11 |
fsVolumeNormalActionsFuel sensor volume return to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.12 |
fsVolumeNormalTrapNumFuel sensor volume return to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.4.1.13 |
fsVolumeNormalClassFuel sensor volume return to normal class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.14 |
fsVolumeLowValueFuel sensor volume low event threshold value. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.15 |
fsVolumeLowActionsFuel sensor volume low event threshold actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.16 |
fsVolumeLowTrapNumFuel sensor volume low event threshold trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.4.1.17 |
fsVolumeLowClassFuel sensor volume low event threshold class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.18 |
fsVolumeVLowValueFuel sensor volume very low event threshold value. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.19 |
fsVolumeVLowActionsFuel sensor volume very low event threshold actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.20 |
fsVolumeVLowTrapNumFuel sensor volume very low event threshold trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.4.1.21 |
fsVolumeVLowClassFuel sensor volume very low event threshold class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.4.1.22 |
fuelSensorDisconnectTableThis table organizes disconnect-event-specific fuel sensor attributes. SEQUENCE OF FuelSensorConfigDisconnect .1.3.6.1.4.1.3052.20.2.12.11.5 |
fsDiscEntryEntry for fuel sensor disconnect event config table. FuelSensorConfigDisconnect .1.3.6.1.4.1.3052.20.2.12.11.5.1 |
fsDiscIndexWhich fuel sensor in the fuel sensor disconnect event config table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.11.5.1.1 |
fsDiscEnableFuel sensor disconnect event enable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.5.1.2 |
fsDiscHighValueHigh end of input value range when fuel sensor is disconnected. This is in the units of the analog input value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.5.1.3 |
fsDiscLowValueLow end of input value range when fuel sensor is disconnected. This is in the units of the analog input value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.5.1.4 |
fsDiscActionsFuel sensor disconnect event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.5.1.5 |
fsDiscTrapNumFuel sensor disconnect event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.5.1.6 |
fsDiscClassFuel sensor disconnect event class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.5.1.7 |
fsDiscNormalActionsFuel sensor disconnect return to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.5.1.8 |
fsDiscNormalTrapNumFuel sensor disconnect return to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.11.5.1.9 |
fsDiscNormalClassFuel sensor disconnect return to normal class (severity).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.11.5.1.10 |
acPowerMonitor OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.12 |
acpmGeneralTableThis table organizes general AC power monitor attributes. SEQUENCE OF ACPMConfigGeneral .1.3.6.1.4.1.3052.20.2.12.12.1 |
acpmGenEntryEntry for AC power monitor general config table. ACPMConfigGeneral .1.3.6.1.4.1.3052.20.2.12.12.1.1 |
acpmGenIndexWhich AC power monitor in the AC power monitor general config table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.12.1.1.1 |
acpmGenDeviceModel of the AC power monitor device. The unit needs this setting to know which registers to poll for the various data items, among other things.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.1.1.2 |
acpmGenNameName for the AC power monitor device.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.1.1.3 |
acpmGenAddressModbus address of the AC power monitor device.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.1.1.4 |
acpmGenPtRatioRatio of secondary turns to primary turns on potential transformers (PT).rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.1.1.5 |
acpmGenCtRatioRatio of secondary turns to primary turns on current transformers (CT).rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.1.1.6 |
acpmGenPowerTypeType of power being monitored.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.1.1.7 |
acpmGenSysrepPackageSystem reporting package number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.1.1.8 |
acpmGenSysrepTypeASM profile type.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.1.1.9 |
acpmGenEnableAC power monitor enable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.1.1.10 |
acpmAvgVoltageTableThis table organizes AC power monitor average voltage attributes. SEQUENCE OF ACPMConfigAvgVoltage .1.3.6.1.4.1.3052.20.2.12.12.2 |
acpmAvgVoltageEntryEntry for AC power monitor average voltage config table. ACPMConfigAvgVoltage .1.3.6.1.4.1.3052.20.2.12.12.2.1 |
acpmAvgVoltageIndexWhich AC power monitor in the AC power monitor average voltage config table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.12.2.1.1 |
acpmAvgVoltageEnableEnable AC power monitor average voltage events.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.2 |
acpmAvgVoltageDeadbandDeadband (hysteresis) for average voltage event. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.3 |
acpmAvgVoltageVHighValueVery high event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.4 |
acpmAvgVoltageVHighActionsVery high event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.5 |
acpmAvgVoltageVHighTrapNumVery high event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.2.1.6 |
acpmAvgVoltageVHighClassVery high event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.7 |
acpmAvgVoltageHighValueHigh event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.8 |
acpmAvgVoltageHighActionsHigh event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.9 |
acpmAvgVoltageHighTrapNumHigh event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.2.1.10 |
acpmAvgVoltageHighClassHigh event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.11 |
acpmAvgVoltageNormalActionsReturn to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.12 |
acpmAvgVoltageNormalTrapNumReturn to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.2.1.13 |
acpmAvgVoltageNormalClassReturn to normal class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.14 |
acpmAvgVoltageLowValueLow event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.15 |
acpmAvgVoltageLowActionsLow event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.16 |
acpmAvgVoltageLowTrapNumLow event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.2.1.17 |
acpmAvgVoltageLowClassLow event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.18 |
acpmAvgVoltageVLowValueVery low event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.19 |
acpmAvgVoltageVLowActionsVery low event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.20 |
acpmAvgVoltageVLowTrapNumVery low event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.2.1.21 |
acpmAvgVoltageVLowClassVery low event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.22 |
acpmAvgVoltageSysrepEnableSystem reporting enable for average voltage telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.23 |
acpmAvgVoltageSysrepThresholdSystem reporting threshold for average voltage telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.2.1.24 |
acpmAvgVoltageSysrepLimitSystem reporting limit for average voltage telemetry.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.2.1.25 |
acpmAvgCurrentTableThis table organizes AC power monitor average current attributes. SEQUENCE OF ACPMConfigAvgCurrent .1.3.6.1.4.1.3052.20.2.12.12.3 |
acpmAvgCurrentEntryEntry for AC power monitor average current config table. ACPMConfigAvgCurrent .1.3.6.1.4.1.3052.20.2.12.12.3.1 |
acpmAvgCurrentIndexWhich AC power monitor in the AC power monitor average current config table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.12.3.1.1 |
acpmAvgCurrentEnableEnable AC power monitor average current events.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.2 |
acpmAvgCurrentDeadbandDeadband (hysteresis) for average current event. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.3 |
acpmAvgCurrentVHighValueVery high event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.4 |
acpmAvgCurrentVHighActionsVery high event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.5 |
acpmAvgCurrentVHighTrapNumVery high event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.3.1.6 |
acpmAvgCurrentVHighClassVery high event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.7 |
acpmAvgCurrentHighValueHigh event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.8 |
acpmAvgCurrentHighActionsHigh event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.9 |
acpmAvgCurrentHighTrapNumHigh event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.3.1.10 |
acpmAvgCurrentHighClassHigh event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.11 |
acpmAvgCurrentNormalActionsReturn to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.12 |
acpmAvgCurrentNormalTrapNumReturn to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.3.1.13 |
acpmAvgCurrentNormalClassReturn to normal class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.14 |
acpmAvgCurrentLowValueLow event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.15 |
acpmAvgCurrentLowActionsLow event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.16 |
acpmAvgCurrentLowTrapNumLow event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.3.1.17 |
acpmAvgCurrentLowClassLow event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.18 |
acpmAvgCurrentVLowValueVery low event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.19 |
acpmAvgCurrentVLowActionsVery low event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.20 |
acpmAvgCurrentVLowTrapNumVery low event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.3.1.21 |
acpmAvgCurrentVLowClassVery low event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.22 |
acpmAvgCurrentSysrepEnableSystem reporting enable for average current telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.23 |
acpmAvgCurrentSysrepThresholdSystem reporting threshold for average current telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.3.1.24 |
acpmAvgCurrentSysrepLimitSystem reporting limit for average current telemetry.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.3.1.25 |
acpmFreqTableThis table organizes AC power monitor frequency attributes. SEQUENCE OF ACPMConfigFreq .1.3.6.1.4.1.3052.20.2.12.12.4 |
acpmFreqEntryEntry for AC power monitor frequency config table. ACPMConfigFreq .1.3.6.1.4.1.3052.20.2.12.12.4.1 |
acpmFreqIndexWhich AC power monitor in the AC power monitor frequency config table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.12.4.1.1 |
acpmFreqEnableEnable AC power monitor frequency events.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.2 |
acpmFreqDeadbandDeadband (hysteresis) for frequency event. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.3 |
acpmFreqVHighValueVery high event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.4 |
acpmFreqVHighActionsVery high event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.5 |
acpmFreqVHighTrapNumVery high event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.4.1.6 |
acpmFreqVHighClassVery high event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.7 |
acpmFreqHighValueHigh event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.8 |
acpmFreqHighActionsHigh event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.9 |
acpmFreqHighTrapNumHigh event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.4.1.10 |
acpmFreqHighClassHigh event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.11 |
acpmFreqNormalActionsReturn to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.12 |
acpmFreqNormalTrapNumReturn to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.4.1.13 |
acpmFreqNormalClassReturn to normal class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.14 |
acpmFreqLowValueLow event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.15 |
acpmFreqLowActionsLow event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.16 |
acpmFreqLowTrapNumLow event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.4.1.17 |
acpmFreqLowClassLow event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.18 |
acpmFreqVLowValueVery low event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.19 |
acpmFreqVLowActionsVery low event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.20 |
acpmFreqVLowTrapNumVery low event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.4.1.21 |
acpmFreqVLowClassVery low event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.22 |
acpmFreqSysrepEnableSystem reporting enable for frequency telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.23 |
acpmFreqSysrepThresholdSystem reporting threshold for frequency telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.4.1.24 |
acpmFreqSysrepLimitSystem reporting limit for frequency telemetry.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.4.1.25 |
acpmTotalRealPowerTableThis table organizes AC power monitor total real power attributes. SEQUENCE OF ACPMConfigTRP .1.3.6.1.4.1.3052.20.2.12.12.5 |
acpmTRPEntryEntry for AC power monitor total real power config table. ACPMConfigTRP .1.3.6.1.4.1.3052.20.2.12.12.5.1 |
acpmTRPIndexWhich AC power monitor in the AC power monitor total real power config table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.12.5.1.1 |
acpmTRPEnableEnable AC power monitor total real power events.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.2 |
acpmTRPDeadbandDeadband (hysteresis) for total real power event. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.3 |
acpmTRPVHighValueVery high event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.4 |
acpmTRPVHighActionsVery high event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.5 |
acpmTRPVHighTrapNumVery high event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.5.1.6 |
acpmTRPVHighClassVery high event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.7 |
acpmTRPHighValueHigh event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.8 |
acpmTRPHighActionsHigh event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.9 |
acpmTRPHighTrapNumHigh event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.5.1.10 |
acpmTRPHighClassHigh event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.11 |
acpmTRPNormalActionsReturn to normal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.12 |
acpmTRPNormalTrapNumReturn to normal trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.5.1.13 |
acpmTRPNormalClassReturn to normal class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.14 |
acpmTRPLowValueLow event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.15 |
acpmTRPLowActionsLow event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.16 |
acpmTRPLowTrapNumLow event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.5.1.17 |
acpmTRPLowClassLow event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.18 |
acpmTRPVLowValueVery low event threshold. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.19 |
acpmTRPVLowActionsVery low event actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.20 |
acpmTRPVLowTrapNumVery low event trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.5.1.21 |
acpmTRPVLowClassVery low event class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.22 |
acpmTRPSysrepEnableSystem reporting enable for total real power telemetry.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.23 |
acpmTRPSysrepThresholdSystem reporting threshold for total real power telemetry. This is a floating point value.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.5.1.24 |
acpmTRPSysrepLimitSystem reporting limit for total real power telemetry.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.5.1.25 |
acpmDisconnectTableThis table organizes AC power monitor device disconnect event attributes. SEQUENCE OF ACPMConfigDisconnect .1.3.6.1.4.1.3052.20.2.12.12.6 |
acpmDisconnectEntryEntry for AC power monitor device disconnect event config table. ACPMConfigDisconnect .1.3.6.1.4.1.3052.20.2.12.12.6.1 |
acpmDisconnectIndexWhich AC power monitor in the AC power monitor device disconnect event config table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.12.6.1.1 |
acpmDisconnectEnableEnable AC power monitor device disconnect event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.6.1.2 |
acpmDisconnectActionsActions for disconnect event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.6.1.3 |
acpmDisconnectTrapNumTrap number for disconnect event.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.6.1.4 |
acpmDisconnectClassClass for disconnect event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.6.1.5 |
acpmDisconnectNormalActionsActions for disconnect return to normal event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.6.1.6 |
acpmDisconnectNormalTrapNumTrap number for disconnect return to normal event.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.6.1.7 |
acpmDisconnectNormalClassClass for disconnect return to normal event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.6.1.8 |
acpmTotalPowerFactorTableThis table organizes AC power monitor device total power factor event attributes. SEQUENCE OF ACPMConfigTotalPowerFactor .1.3.6.1.4.1.3052.20.2.12.12.7 |
acpmTPFEntryEntry for AC power monitor device total power factor event config table. ACPMConfigTotalPowerFactor .1.3.6.1.4.1.3052.20.2.12.12.7.1 |
acpmTPFIndexWhich AC power monitor in the AC power monitor device disconnect event config table.ro Integer32 .1.3.6.1.4.1.3052.20.2.12.12.7.1.1 |
acpmTPFEnableEnable AC power monitor device disconnect event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.2 |
acpmTPFDeadbandDeadband (hysteresis).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.3 |
acpmTPFNormalActionsNormal actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.4 |
acpmTPFNormalTrapNumNormal trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.7.1.5 |
acpmTPFNormalClassNormal class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.6 |
acpmTPFLowValueLow threshold.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.7 |
acpmTPFLowActionsLow actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.8 |
acpmTPFLowTrapNumLow trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.7.1.9 |
acpmTPFLowClassLow class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.10 |
acpmTPFVLowValueVery Low threshold.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.11 |
acpmTPFVLowActionsVery Low actions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.12 |
acpmTPFVLowTrapNumVery Low trap number.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.7.1.13 |
acpmTPFVLowClassVery Low class.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.14 |
acpmTPFSysrepEnableSystem reporting enable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.15 |
acpmTPFSysrepThresholdSystem reporting threshold.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.12.7.1.16 |
acpmTPFSysrepLimitSystem reporting limit.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.12.7.1.17 |
evReset OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.12.16 |
evResetEnableEnable/disable reset event. This event is triggered when the unit finishes booting.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.16.1 |
evResetDelayNumber of seconds to wait after unit finishes booting before triggering the reset event.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.16.2 |
evResetActionsActions for reset event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.16.3 |
evResetMessageMessage for reset event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.16.4 |
evResetTrapnumTrap number for reset event.rw Integer32 .1.3.6.1.4.1.3052.20.2.12.16.5 |
evResetClassClass (severity) for reset event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.12.16.6 |
action OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.14 |
actionCallNumberTableTable of phone numbers to dial for modem actions SEQUENCE OF ActionCallNumberConfig .1.3.6.1.4.1.3052.20.2.14.1 |
actionCallNumberEntryEntry for table of phone numbers to dial for modem actions ActionCallNumberConfig .1.3.6.1.4.1.3052.20.2.14.1.1 |
actionCallNumberIndexIndex for table of phone numbers to dial for modem actionsro Integer32 .1.3.6.1.4.1.3052.20.2.14.1.1.1 |
actionCallNumberThe number to dial for this action slotrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.1.1.2 |
actionPagerTableTable of pager configurations SEQUENCE OF ActionPagerConfig .1.3.6.1.4.1.3052.20.2.14.2 |
actionPagerEntryEntry for table of pager configurations ActionPagerConfig .1.3.6.1.4.1.3052.20.2.14.2.1 |
actionPagerIndexindex for table of pager configurationsro Integer32 .1.3.6.1.4.1.3052.20.2.14.2.1.1 |
actionPagerTypetype of this pager configurationrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.2.1.2 |
actionPagerNumberphone number to dial for this pager configurationrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.2.1.3 |
actionPagerIDID to use for this pager configurationrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.2.1.4 |
actionPagerMessagemessage to use for this pager configurationrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.2.1.5 |
actionPagerPostCalloutDelaySeconds to wait after dialing before sending IDrw Integer32 .1.3.6.1.4.1.3052.20.2.14.2.1.6 |
actionPagerPostIDDelaySeconds to wait after sending ID to send messagerw Integer32 .1.3.6.1.4.1.3052.20.2.14.2.1.7 |
actionSched OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.14.3 |
actionSchedEnableON/OFF enable action schedulerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.3.1 |
actionSchedBeginaction schedule begin time (HH:MM)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.3.2 |
actionSchedEndaction schedule end time (HH:MM)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.3.3 |
actionSchedWeekdaysOnlyON/OFF whether the action schedule applies to weekdays only (ON) or all days (OFF)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.3.4 |
actionAsentria OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.14.4 |
actionAsentriaRequireAckON/OFF Asentria action requires an ack from the receiverrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.4.1 |
actionAsentriaVersionversion 1.0 or 1.1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.4.2 |
actionAsentriaTCPPortTCP port used for TCP-based Asentria alarmsrw Integer32 .1.3.6.1.4.1.3052.20.2.14.4.3 |
actionHostTableTable of network hosts to use for network-based actions SEQUENCE OF ActionHostConfig .1.3.6.1.4.1.3052.20.2.14.6 |
actionHostEntryEntry for table of network hosts to use for network-based actions ActionHostConfig .1.3.6.1.4.1.3052.20.2.14.6.1 |
actionHostIndexIndex for table of network hosts to use for network-based actionsro Integer32 .1.3.6.1.4.1.3052.20.2.14.6.1.1 |
actionHostHostname/IP address used as destination for network-based action (e.g., trap)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.6.1.2 |
actionEmailTableTable of email addresses to use for email actions SEQUENCE OF ActionEmailConfig .1.3.6.1.4.1.3052.20.2.14.7 |
actionEmailEntryEntry for table of email addresses to use for email actions ActionEmailConfig .1.3.6.1.4.1.3052.20.2.14.7.1 |
actionEmailIndexIndex for table of email addresses to use for email actionsro Integer32 .1.3.6.1.4.1.3052.20.2.14.7.1.1 |
actionEmailemail addressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.7.1.2 |
actionParseErrorWhen a user attempts to configure an invalid action setting/ object, this object says why it was invalid.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.14.8 |
sys OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.16 |
sysTime OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.16.1 |
sysTimeAutoDSTON/OFF automatically adjust for Daylight Savings Timerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.1.1 |
sysTimeGMTOffsetAbsolute value of offset (hours) from GMT of the timezonerw Integer32 .1.3.6.1.4.1.3052.20.2.16.1.2 |
sysTimeGMTDirectionDirection (AHEAD/BEHIND) of timezone relative to GMTrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.1.3 |
sysTimeNet OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.16.1.4 |
sysTimeNetEnableNetwork time moderw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.1.4.1 |
sysTimeNetHostTableTable of hosts to use for network time services SEQUENCE OF NetworkTimeHostConfig .1.3.6.1.4.1.3052.20.2.16.1.4.2 |
sysTimeNetHostEntryEntry for table of hosts to use for network time services NetworkTimeHostConfig .1.3.6.1.4.1.3052.20.2.16.1.4.2.1 |
sysTimeNetHostIndexIndex for table of hosts to use for network time servicesro Integer32 .1.3.6.1.4.1.3052.20.2.16.1.4.2.1.1 |
sysTimeNetHosthost to use for network time servicesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.1.4.2.1.2 |
sysPT OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.16.2 |
sysPTTimeoutTimeout (minutes) of inactivity after which a pass-through session is terminated (0 means it never terminates)rw Integer32 .1.3.6.1.4.1.3052.20.2.16.2.1 |
sysPTEndPausenumber of 16ths of a second between escape characters received on pass-through origin IO handle that are reuired for the escape characters to register as pass-through escape characters in the pass-through escape sequence. Set to 0 to make the escape character register as part of the pass- through escape sequence without requiring a pause.rw Integer32 .1.3.6.1.4.1.3052.20.2.16.2.2 |
sysPTJoinableEnable joinable pass-through sessions.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.2.3 |
sysMTUMaximum transfer unit for ethernet interfacesrw Integer32 .1.3.6.1.4.1.3052.20.2.16.3 |
sysAnswerStringString displayed upon loginrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.4 |
sysEventFileIDID string for events filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.6 |
sysEscapeCharacterDecimal ASCII code of the system escape characterrw Integer32 .1.3.6.1.4.1.3052.20.2.16.7 |
sysTimeStamp OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.16.8 |
sysTimeStampTimeFormatFormat of time stamp: HH:MM,HH:MM:SS,BLANKrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.8.1 |
sysTimeStampDateFormatFormat of date stamp: MM/DD,MM/DD/YY,MM/DD/YYYY,BLANKrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.8.2 |
sysTimeStampSpaceAfterON/OFF Inlude a space after timestamprw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.8.3 |
sysLog OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.16.9 |
sysLogModeSyslog mode: disabled, emit UDP (REMOTE), save in a rotating file set (FILE), or emit on a listening socket (SERVER)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.9.1 |
sysLoghostSyslog host: destination machine when syslog mode is REMOTErw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.9.2 |
sysLogFilterString describing what functions place data in the syslogrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.9.3 |
sysLogFileSizeSize (in KB) of syslog files (when syslog mode is SERVER or FILE)rw Integer32 .1.3.6.1.4.1.3052.20.2.16.9.4 |
sysLogFileCountNumber of files in syslog file set (when syslog mode is SERVER or FILE)rw Integer32 .1.3.6.1.4.1.3052.20.2.16.9.5 |
sysLogListenPortTCP port on which the unit listens for a connection on which syslog data is dumped (when syslog mode is SERVER)rw Integer32 .1.3.6.1.4.1.3052.20.2.16.9.6 |
sysCRDB OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.16.10 |
sysCRDBCapacityCapacity of Call Record Database (in KB)ro Integer32 .1.3.6.1.4.1.3052.20.2.16.10.1 |
sysCRDBPercentFullPercent of the CRDB usedro Integer32 .1.3.6.1.4.1.3052.20.2.16.10.2 |
sysCRDBFileIDTableTable of CRDB file IDs SEQUENCE OF CRDBFileIDConfig .1.3.6.1.4.1.3052.20.2.16.10.3 |
sysCRDBFileIDEntryEntry for table of CRDB file IDs CRDBFileIDConfig .1.3.6.1.4.1.3052.20.2.16.10.3.1 |
sysCRDBFileIDIndexIndex for table of CRDB file IDsro Integer32 .1.3.6.1.4.1.3052.20.2.16.10.3.1.1 |
sysCRDBFileIDID of CRDB file for this port-associated file xrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.10.3.1.2 |
sysCRDBFileEnforceMinTableTable of CRDB file minimum size enforcement settings SEQUENCE OF CRDBFileEnforceMinConfig .1.3.6.1.4.1.3052.20.2.16.10.4 |
sysCRDBFileEnforceMinEntryEntry for table of CRDB file minimum size enforcement settings CRDBFileEnforceMinConfig .1.3.6.1.4.1.3052.20.2.16.10.4.1 |
sysCRDBFileEnforceMinIndexIndex for table of CRDB file minimum size enforcement settingsro Integer32 .1.3.6.1.4.1.3052.20.2.16.10.4.1.1 |
sysCRDBFileEnforceMinON/OFF: enforce minimum size for this CRDB file xrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.10.4.1.2 |
sysCharMaskCharacter mask used for ignoring certain characters on serial ports when assembling data records (when port mode is ASCII)rw OCTET STRING .1.3.6.1.4.1.3052.20.2.16.11 |
sysPromptPrompt to use in a commnand sessionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.12 |
sysBootStatusString describing the boot status of the unit (Booted OK/ still bootingro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.13 |
sysLoc OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.16.14 |
sysLocLatitudeLatitude portion of geographic coordinates as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.14.1 |
sysLocLongitudeLongitude portion of geographic coordinates as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.14.2 |
sysLocXOffsetX-offset portion of geographic coordinates as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.14.3 |
sysLocYOffsetY offset portion of geographic coordinates as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.14.4 |
sysLocAngleAngle portion of geographic coordinates as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.14.5 |
sysLocAltitudeAltitude portion of geographic coordinates as stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.14.6 |
sysAssetMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.16.15 |
sysAMManufacturerDevice manufacturerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.15.1 |
sysAMProductDevice product description (i.e., model or model number)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.15.2 |
sysAMSerialNumberManufacturer serial number for devicero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.15.3 |
sysAMHardwareOptionsHardware options currently installed on devicero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.15.4 |
sysAMSoftwareVersionCurrently-running software version on devicero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.15.5 |
sysAMSiteNameSite Name of device (user definable, also known as the siteName object under the productIds branch.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.15.6 |
sysFileTransfer OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.16.17 |
sysFileTransferStatusStart/cancel file transfer, or check transfer status. To start, set this object to 'start'. To cancel, set this object to 'cancel'. To check status, get the objectrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.17.1 |
sysFileTransferURLURL (describing protocol, host, directory, and file) on which file transfer function operates.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.17.2 |
sysFileTransferUsernameUsername for user account at the resource specified by sysFileTransferURL.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.17.3 |
sysFileTransferPasswordPassword for user account at the resource specified by sysFileTransferURL.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.17.4 |
sysUpdate OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.16.18 |
sysUpdateStatusCheck time/result of last update attempt.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.16.18.1 |
auditLog OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.17 |
auditLogEnableON/OFF enable audit logrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.17.1 |
auditLogStoreResetsON/OFF audit log stores when the unit resetsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.17.2 |
auditLogStoreCommandsON/OFF audit log stores commands entered in a command sessionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.17.3 |
auditLogStoreOutputsON/OFF audit log stores output (relay output and power output) activityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.17.4 |
auditLogStoreAlarmActionsON/OFF audit log stores action delivery activityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.17.5 |
auditLogStorePwdFailuresON/OFF audit log stores when user was denied loginrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.17.6 |
auditLogStoreLoginsON/OFF audit log stores when a user was allowed loginrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.17.7 |
auditLogStoreSHSKON/OFF audit log stores serial handshaking status (regardless of serial handshaking event)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.17.8 |
auditLogStorePassthroughON/OFF audit log stores pass-through activityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.17.9 |
auditLogStoreInactivityON/OFF audit log stores when sessions expire due to inactivityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.17.10 |
auditLogStorePollingON/OFF audit log stores CRDB polling activityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.17.11 |
auditLogMaxSizeMaximum size (in KB) of audit logrw Integer32 .1.3.6.1.4.1.3052.20.2.17.12 |
scripting OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.2.18 |
scrGlobalEnableON/OFF enable scriptingrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.1 |
scrDTRCtrlPortEnableTableTable of DTR control port enables SEQUENCE OF ScriptingDTRCtrlPortEnableConfig .1.3.6.1.4.1.3052.20.2.18.2 |
scrDTRCtrlPortEnableEntryEntry for table of DTR control port enables ScriptingDTRCtrlPortEnableConfig .1.3.6.1.4.1.3052.20.2.18.2.1 |
scrDTRCtrlPortEnableIndexIndex for table of DTR control port enablesro Integer32 .1.3.6.1.4.1.3052.20.2.18.2.1.1 |
scrDTRCtrlPortEnableON/OFF enable DTR control of scripting for this portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.2.1.2 |
scrTableTable of scripts SEQUENCE OF ScriptingConfig .1.3.6.1.4.1.3052.20.2.18.3 |
scrEntryEntry for table of scripts ScriptingConfig .1.3.6.1.4.1.3052.20.2.18.3.1 |
scrIndexIndex for table of scriptsro Integer32 .1.3.6.1.4.1.3052.20.2.18.3.1.1 |
scrEnableON/OFF enable this scriptrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.3.1.2 |
scrNameName of this scriptrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.3.1.3 |
scrFilenameFilename for this scriptrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.3.1.4 |
scrRunAlwaysON/OFF: this script always runsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.3.1.5 |
scrRunAtStartupON/OFF: this script runs at startuprw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.3.1.6 |
scrRunScheduledON/OFF: this script runs at a certain time of dayrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.3.1.7 |
scrScheduleTimeTime of day (HH:MM) this script is scheduled to runrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.3.1.8 |
scrArgumentsArguments for this scriptrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.3.1.9 |
scrRepeatIntervalHow often this script runs (minutes)rw Integer32 .1.3.6.1.4.1.3052.20.2.18.3.1.10 |
scrVolatileStringTableTable of volatile string settings for use in scripts. SEQUENCE OF ScriptingVolatileString .1.3.6.1.4.1.3052.20.2.18.4 |
scrVolatileStringEntryEntry for table of volatile script string settings ScriptingVolatileString .1.3.6.1.4.1.3052.20.2.18.4.1 |
scrVolatileStringIndexIndex for table of volatile script string settingsro Integer32 .1.3.6.1.4.1.3052.20.2.18.4.1.1 |
scrVolatileStringVolatile string for use in scripts. Use this object to cache frequently-changing string values or string values that do not need to persist through reset. This object corresponds to the scripting.vstring[] setting key branch; use those keys in scripts and you can view or change their values with this object.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.4.1.2 |
scrVolatileIntTableTable of volatile integer settings for use in scripts. SEQUENCE OF ScriptingVolatileInt .1.3.6.1.4.1.3052.20.2.18.5 |
scrVolatileIntEntryEntry for table of volatile script integer settings ScriptingVolatileInt .1.3.6.1.4.1.3052.20.2.18.5.1 |
scrVolatileIntIndexIndex for table of volatile script integer settingsro Integer32 .1.3.6.1.4.1.3052.20.2.18.5.1.1 |
scrVolatileIntVolatile integer for use in scripts. Use this object to cache frequently-changing integer values or integer values that do not need to persist through reset. This object corresponds to the scripting.vint[] setting key branch; use those keys in scripts and you can view or change their values with this object.rw Integer32 .1.3.6.1.4.1.3052.20.2.18.5.1.2 |
scrNonVolatileStringTableTable of non-volatile string settings for use in scripts. SEQUENCE OF ScriptingNonVolatileString .1.3.6.1.4.1.3052.20.2.18.6 |
scrNonVolatileStringEntryEntry for table of non-volatile script string settings ScriptingNonVolatileString .1.3.6.1.4.1.3052.20.2.18.6.1 |
scrNonVolatileStringIndexIndex for table of non-volatile script string settingsro Integer32 .1.3.6.1.4.1.3052.20.2.18.6.1.1 |
scrNonVolatileStringNon-volatile string for use in scripts. Use this object to store values that need to persist through reset. This object corresponds to the scripting.nvstring[] setting key branch; use those keys in scripts and you can view or change their values with this object. Note: to store frequently- changing integers, use the scrVolatileString object, otherwise your scripts may cause unnecessary wear of the non-volatile storage medium on the unit.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.2.18.6.1.2 |
scrNonVolatileIntTableTable of non-volatile integer settings for use in scripts. SEQUENCE OF ScriptingNonVolatileInt .1.3.6.1.4.1.3052.20.2.18.7 |
scrNonVolatileIntEntryEntry for table of non-volatile script integer settings ScriptingNonVolatileInt .1.3.6.1.4.1.3052.20.2.18.7.1 |
scrNonVolatileIntIndexIndex for table of non-volatile script integer settingsro Integer32 .1.3.6.1.4.1.3052.20.2.18.7.1.1 |
scrNonVolatileIntNon-volatile integer for use in scripts. Use this object to store integer values that need to persist through reset. This object corresponds to the scripting.nvint[] setting key branch; use those keys in scripts and you can view or change their values with this object. Note: to store frequently- changing integers, use the scrVolatileInt object, otherwise your scripts may cause unnecessary wear of the non-volatile storage medium on the unit.rw Integer32 .1.3.6.1.4.1.3052.20.2.18.7.1.2 |
productIds OBJECT IDENTIFIER .1.3.6.1.4.1.3052.20.3 |
siteNameSite Name string; Max 40 characters.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.3.1 |
thisProductThis is a factory configured string for the product name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.3.2 |
stockTrapStringThe message defined for the event that triggers a trap.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.3.3 |
trapEventTypeNumberThe user-defined trap variable for the type of event that happened. Definitions: 4 Scheduled 7 Serial Handshaking Low 8 Serial Handshaking High 10 Contact Closure Active 11 Contact Closure Inactive 12 Temperature High 13 Temperature Very High 14 Temperature Low 15 Temperature Very Low 16 Temperature Return to Normal 17 Humidity High 18 Humidity Very High 19 Humidity Low 20 Humidity Very Low 21 Humidity Return to Normal 26 Analog High 27 Analog Very High 28 Analog Low 29 Analog Very Low 30 Analog Normal 40 EventSensor Unresponsive 41 Custom 42 CPE Down 44 CPE Normal 47 Power Distribution 49 Fuel Sensor Disconnect 50 Fuel Sensor Disconnect Return to Normal 52 AISG Device Alarm 53 AISG Device Alarm Return to Normal 54 AISG Device Unresponsive 55 AISG Device Unresponsive Return to Normal 56 Fuel Sensor 57 AC Power Monitor Average Voltage Very Low 58 AC Power Monitor Average Voltage Low 59 AC Power Monitor Average Voltage Return to Normal 60 AC Power Monitor Average Voltage High 61 AC Power Monitor Average Voltage Very High 62 AC Power Monitor Average Current Very Low 63 AC Power Monitor Average Current Low 64 AC Power Monitor Average Current Return to Normal 65 AC Power Monitor Average Current High 66 AC Power Monitor Average Current Very High 67 AC Power Monitor Frequency Very Low 68 AC Power Monitor Frequency Low 69 AC Power Monitor Frequency Return to Normal 70 AC Power Monitor Frequency High 71 AC Power Monitor Frequency Very High 72 AC Power Monitor Total Real Power Very Low 73 AC Power Monitor Total Real Power Low 74 AC Power Monitor Total Real Power Return to Normal 75 AC Power Monitor Total Real Power High 76 AC Power Monitor Total Real Power Very High 77 AC Power Monitor Disconnect 78 AC Power Monitor Disconnect Return to Normal 79 Load Shedding Started 80 Load Shedding Ended 81 Fuel Sensor Volume Sudden Change 82 Fuel Sensor Volume Slow Change 83 CPE Down Reminder 84 AC Power Monitor Total Power Factor Very Low 85 AC Power Monitor Total Power Factor Low 86 AC Power Monitor Total Power Factor Return to Normal 100 Contact Closure Active Reminder 101 Temperature High Reminder 102 Temperature High Very Reminder 103 Temperature Low Reminder 104 Temperature Very Low Reminder 105 Humidity High Reminder 106 Humidity Very High Reminder 107 Humidity Low Reminder 108 Humidity Very Low Reminder 109 Analog High Reminder 110 Analog Very High Reminder 111 Analog Low Reminder 112 Analog Very Low Reminder 130 Relay Output Active 131 Relay Output Inactive 132 Power Output On 133 Power Output Off 164 Reset 166 Fuel Sensor Levels Auto Adjustro Integer32 .1.3.6.1.4.1.3052.20.3.4 |
trapEventTypeNameThe user-defined trap variable for the string corresponding to the event type.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.3.5 |
trapIncludedValueThe user-defined trap variable for the generic included value.ro Integer32 (-2147483648..2147483647) .1.3.6.1.4.1.3052.20.3.6 |
trapIncludedStringThe user-defined trap variable for the generic included string.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.3.7 |
trapTypeStringThe cause of the trap, added for DL880 compatibility.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.3.8 |
trapEventClassNumberThe user-defined trap variable for the configurable class number associated with the triggering event.ro Integer32 .1.3.6.1.4.1.3052.20.3.9 |
trapEventClassNameThe user-defined trap variable for the configurable class name associated with the class number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.3.10 |
keyInterfaceThis object represents a setting key interface. When setting this object, the value to set is the 'sk' command you would enter on the command line (without the 'sk'). To get the result of the operation, read this object after you write it. For example, to configure EventSensor 1 contact closure 34 event actions to be an SNMP InformRequest to host foo, set this object to: 'event.sensor[1].cc[34].eventactions=inform(foo)'. The SNMP response is the result of the operation: if setting that key to that value was a success then the SNMP response will be a success and the response value will be what you had set. If you subsequently read this object then you will see a message 'OK: ...'. If setting that key to that value failed then the SNMP response will be a failure (a badValue response). If you subsequently read this object then the value returned is the reason that setting that key to that value failed. For another example, to read user 3's pass-through access for port 7, set this object to: 'sec.user[3].port[7].ptaccess'. The SNMP response is the result of the operation: if reading that key is a success then the SNMP response will be a success and the response value will be what you had SET (i.e., the opertion of reading a key, which is just the key itself with no '=' operator, and this is not the key value you want to read). If you subsequently read this object then the value returned is the value of the key you want to read. If reading that key failed (e.g., if the key is invalid) then the SNMP response to your SNMP set operation (the value you set being the invalid key to read) will be a failure (a badValue response). If you subsequently read this object then the value returned is the reason that reading that key failed (i.e., 'invalid key').rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3052.20.4 |