SL-TESTS-MIB
The SL-TESTS-MIB module enables the execution of on-demand connectivity and service layer diagnostics, such as ping and traceroute tests, to verify network reachability and path integrity. It provides a standardized interface for triggering these active probes and retrieving their immediate results for real-time fault isolation.
Imported Objects
Objects
17 total| Object Name |
|---|
slTestsThis MIB module describes the available on-demand tests. MODULE-IDENTITY .1.3.6.1.4.1.4515.1.3.13 |
slTestsIfLoop OBJECT IDENTIFIER .1.3.6.1.4.1.4515.1.3.13.1 |
slTestsIfLoopTableThe port loopback test table. This table controls the
port loopback tests. SEQUENCE OF SlTestsIfLoopEntry .1.3.6.1.4.1.4515.1.3.13.1.1 |
slTestsIfLoopEntryThis entry is used to operate an port loopback test. SlTestsIfLoopEntry .1.3.6.1.4.1.4515.1.3.13.1.1.1 |
slTestsIfLoopIfIndexThe Interface Index of the port that should be loopped back.ro InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4515.1.3.13.1.1.1.1 |
slTestsIfLoopDurationThe test duration in 1/10 Sec. The maximum allowed
duration is 1 hour. After this time the port configuration
returns to its original setting and the Agent automatically
deletes the entry from the table.rw INTEGER .1.3.6.1.4.1.4515.1.3.13.1.1.1.2 |
slTestsIfLoopStatusThis variable is used to start or stop a loopback test.
In order to start a test the NMS should set the value to start(1).
If the test mode is toggle, the NMS should stop the test by setting the value
to stop(2).
In the case of prbs test, after the test has stopped,
if the test fails the value of the status shall be fail(3).rw Enumeration .1.3.6.1.4.1.4515.1.3.13.1.1.1.3 |
slTestsIfLoopTypeThe loopback type:
facility
The received signal at this interface is looped back
out through the corresponding transmitter in the return
direction.
terminal
The signal that is about to be transmitted is connected
to the associated incoming receiver.
prbs
send and recieve prbs pattern.
otnPrbs
send and receive OTN prbsrw Enumeration .1.3.6.1.4.1.4515.1.3.13.1.1.1.5 |
slTestsIfLoopModeThe loopback mode:
timeout
In this mode the duration of the loopback is determined
by the slTestsIfLoopDuration object.
toggle
In this mode the loopback should be toggled explicitly
by the user.rw Enumeration .1.3.6.1.4.1.4515.1.3.13.1.1.1.6 |
slTestsIfLoopErrorsThe prbs errors are counted only of the test succeeded.ro Counter32 .1.3.6.1.4.1.4515.1.3.13.1.1.1.7 |
slTestsIfLoopResultThis variable is used for prbs test result indication.ro Enumeration .1.3.6.1.4.1.4515.1.3.13.1.1.1.8 |
slTestsIfLoopPassedSecondsNumber of seconds passed since the test started.ro INTEGER .1.3.6.1.4.1.4515.1.3.13.1.1.1.9 |
slTestsTraps OBJECT IDENTIFIER .1.3.6.1.4.1.4515.1.3.13.2 |
slTestsTraps0 OBJECT IDENTIFIER .1.3.6.1.4.1.4515.1.3.13.2.0 |
slTestsTrapsLoopbackTableChanged0A slTestsTrapsLoopbackTableChanged trap is sent when the
content of slTestsIfLoopTable changes. When the loop back is deleted
the returned value of slTestsIfLoopActivity should be false. NOTIFICATION-TYPE .1.3.6.1.4.1.4515.1.3.13.2.0.2 |
slTestsTrapsLoopbackActiveThe Loopback is active Yes/No.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.4515.1.3.13.2.1 |
slTestsTrapsLoopbackTableChangedA slTestsTrapsLoopbackTableChanged trap is sent when the
content of slTestsIfLoopTable changes. When the loop back is deleted
the returned value of slTestsIfLoopActivity should be false. NOTIFICATION-TYPE .1.3.6.1.4.1.4515.1.3.13.2.2 |
More MIBs from Argon
Browse all ArgonMIBs →SNMP MIB module
SNMP MIB module
SNMP MIB module
The SL-MAIN-MIB module provides SNMP access to monitor and manage the operational status, hardware health, and system resources of the main board on Schneider Electric (formerly Telemecanique) industrial automation controllers. It exposes critical metrics including CPU utilization, memory usage, temperature sensors, and power supply states to facilitate real-time fault detection and preventive maintenance.
SNMP MIB module
The SL-ETH-MIB module enables monitoring of Ethernet service parameters, specifically tracking interface statistics, service instance states, and traffic counters for SLA-compliant Ethernet services on Silex (or compatible) network equipment. It facilitates the verification of service connectivity and performance metrics required for SLA enforcement and fault isolation in carrier-grade Ethernet deployments.