Home/Catalog/SL-SONET-MIB

SL-SONET-MIB

AI MIB Summary

The SL-SONET-MIB module provides SNMP management extensions for SiteLight SONET service equipment, enabling the monitoring of SONET-specific performance metrics and operational states defined in RFC 2558. This implementation facilitates the collection of critical circuit-level data, including signal integrity, alarm conditions, and service availability for SiteLight optical transport devices.

This MIB module describes the SiteLight SONET Service. The mib contains the extensions required for the rfc2558.
Main OID:
slSonetMib.1.3.6.1.4.1.4515.1.6
70
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

70 total
Object Name
slSonetMibThis MIB module describes the SiteLight SONET Service. The mib contains the extensions required for the rfc2558.
MODULE-IDENTITY
.1.3.6.1.4.1.4515.1.6
slSonetConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.6.1
slSonetConfigTableThe SONET/SDH configuration table. This table has objects for configuring sonet lines.
SEQUENCE OF SlSonetConfigEntry
.1.3.6.1.4.1.4515.1.6.1.1
slSonetConfigEntryAn entry in the table. There is an entry for each SONET line in the table. Entries are automatically created for an ifType value of sonet(39). 'ifAdminStatus' from the ifTable must be used to enable or disable a line. By default, the line state is down.
SlSonetConfigEntry
.1.3.6.1.4.1.4515.1.6.1.1.1
slSonetConfigFrameScrambleThis object is used to disable or enable the Scrambling option in SONET line. Please refer to GR-253-CORE for frame scrambling.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.1
slSonetConfigTypeThis object represents the configured line type for Trunks: sonetSts48c(5) - 1 x Sts48 (2.5GbTrunk) sonetSts192c(12) - 1 x Sts192 (10Gb Trunk) sonetStsOther(13) - for OC-n interfaces see slSonetFsTable.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.2
slSonetConfigDccSelectionThis object selects the DCC type.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.3
slSonetResetAllCountersSetting this variable to 1 will cause all of the counters (performance regsters) on this SONET interface to be initialized to zero (0).rw
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.4
slSonetPortThresholdTrapEnableThis variable indicates whether threshold traps should be generated for this SONET interface.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.5
slSonetConfigSdThresholdThis object contains the Bit Error Rate threshold for Signal Degrade detection on the working line. Once this threshold is exceeded, an APS switch will occur. This value is 10 to -n where n is between 5 and 9 (read-write).rw
INTEGER
.1.3.6.1.4.1.4515.1.6.1.1.1.6
slSonetConfigSfThresholdThis object contains the Bit Error Rate threshold for Signal Fault detection on the working line. Once this threshold is exceeded, an APS switch will occur. This value is 10 to the -n, where n is between 3 and 5. (read-write)rw
INTEGER
.1.3.6.1.4.1.4515.1.6.1.1.1.7
slSonetCompressionThis object applies only for trunk ports. It specifies if the packets should be compressed. 0 - Means no POS compression, 1 - Means POS compression with CRC-32. 2 - Means POS compression with CRC-16. Note that the two connected trunks should be configured to the same value. Note also that the BW calculation of the OC-n should be changed according to this value.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.9
slSonetOverheadTunnelingThe section and line overhead tunneling configuration: none(0) - no tunneling support lineDcc(1) - line DCC tunneling k1k2(2) - line DCC + protection k byte full(3) - all transport overhead bytes are tunneledrw
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.10
slSonetLopBitmaskThe LOP status. Each bit of the bits represent the status of the LOP alarm in corresponding STS. For a path with more than a single STS, only the value of the first STS in the path is relevant. This object is relevant only for the OC-N cards and not for the Trunk. In the next future this object will be replaced with an object of a new table that shall describe the OC-N frame structure.ro
Counter64
.1.3.6.1.4.1.4515.1.6.1.1.1.11
slSonetTdmTrunkThis object is applicable only to the OC-n ports. TRUE - means that the OC-n port is used as a TDM Trunk. FLASE - means normal OC-n port.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4515.1.6.1.1.1.12
slSonetFsApplyWriting to this object activate the slSonetFsTable setting. This allow the NMS to do many changes to the slSonetFsTable and then APPLY them at once. This prevent from going through unconsistent steps. This object always returns the value 0.rw
INTEGER
.1.3.6.1.4.1.4515.1.6.1.1.1.13
slSonetTxLteThe SS bits to transmit (bits 5,6 in H1,H1*).rw
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.14
slSonetReceivedLteThe detected LTE type, according to the received SS bits (bits 5,6 in H1,H1*).ro
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.15
slSonetResetPmThresholdSetting this variable to 1 will reset the PM threshold parameters to the factory defaults.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.16
slSonetResetAlsParamsSetting this variable to 1 will reset the ALS parameters to the factory defaults.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.17
slSonetTransceiverTypeThe tranceiver type.ro
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.18
slSonetTransceiverMediaThe tranceiver media.ro
Enumeration
.1.3.6.1.4.1.4515.1.6.1.1.1.19
slSonetOh
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.6.2
slSonetOhTrace
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.6.2.1
slSonetTraceTableThe SONET/SDH Trace table. This table contains objects for tracing the sonet section and path.
SEQUENCE OF SlSonetTraceEntry
.1.3.6.1.4.1.4515.1.6.2.1.1
slSonetTraceEntryAn entry in the trace table. Entries exist for active sonet interfaces. The objects in this table are used to verify continued connection between the two ends of the line.
SlSonetTraceEntry
.1.3.6.1.4.1.4515.1.6.2.1.1.1
slSonetTraceModeDetermine the Trace Message Mode.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.2.1.1.1.1
slSonetTraceToTransmitSonet Trace To Transmit. This is string that is transmitted to perform Sonet trace diagnostics. The trace string is repetitively transmited so that a trace receiving terminal can verify its continued connection to the intended transmitter. The default value is a zero-length string. Unless this object is set to a non-zero length string, tracing will not be performed. The Agent is responsible to pad the end of the string with <CR><LF>.rw
DisplayString
.1.3.6.1.4.1.4515.1.6.2.1.1.1.2
slSonetTraceToExpectSonet Trace Massage To Expect. The receiving terminal verifies if the incoming string matches this string. The value of 'slSonetTraceFailure' indicates whether a trace mismatch occurred. The default value is a zero-length string. The Agent is responsible to pad the end of the string with <CR><LF>.rw
DisplayString
.1.3.6.1.4.1.4515.1.6.2.1.1.1.3
slSonetTraceFailureThe value of this object is set to 'true' when Sonet Section received trace does not match the 'slSonetTraceToExpect'.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4515.1.6.2.1.1.1.4
slSonetTraceReceivedThis object is used to view the Sonet Trace Message that is received by the receiving terminal. The Agent is responsible to pad the end of the string with <CR><LF>.ro
DisplayString
.1.3.6.1.4.1.4515.1.6.2.1.1.1.5
slSonetOhSl
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.6.2.2
slSonetSlTableThe SONET/SDH Signal Label table. This table contains signal label for the sonet path.
SEQUENCE OF SlSonetSlEntry
.1.3.6.1.4.1.4515.1.6.2.2.1
slSonetSlEntryAn entry in the SONET/SDH Signal Label table. The entries exist for active sonet lines. The objects in this table are used to verify continued connection between the two ends of the line.
SlSonetSlEntry
.1.3.6.1.4.1.4515.1.6.2.2.1.1
slSonetSlToTransmitSonet Signal Label To Transmit.rw
SignalLabel
.1.3.6.1.4.1.4515.1.6.2.2.1.1.2
slSonetSlToExpectSonet Signal Label To Expect.rw
SignalLabel
.1.3.6.1.4.1.4515.1.6.2.2.1.1.3
slSonetSlFailureThe value of this object is set to 'true' when Sonet received signal label does not match the 'slSonetSlToExpect'.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4515.1.6.2.2.1.1.4
slSonetSlReceivedThis object is used to view the Sonet Signal Label that is received by the receiving terminal.ro
INTEGER
.1.3.6.1.4.1.4515.1.6.2.2.1.1.5
slSonetOhTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.6.2.3
slSonetPos
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.6.6
slSonetPosTableThe POS PM Table.
SEQUENCE OF SlSonetPosEntry
.1.3.6.1.4.1.4515.1.6.6.1
slSonetPosEntryThe entries exist for active Trunk sonet lines ifType = pos(171). The objects in this table are used to moitor the POS layer.
SlSonetPosEntry
.1.3.6.1.4.1.4515.1.6.6.1.1
slSonetPosFcsThe Number of FCS Errors.ro
Gauge32
.1.3.6.1.4.1.4515.1.6.6.1.1.1
slSonetPosAbortThe Number of Aborted packets.ro
Gauge32
.1.3.6.1.4.1.4515.1.6.6.1.1.2
slSonetPosMinViolationThe Number of Minimum length violation packets.ro
Gauge32
.1.3.6.1.4.1.4515.1.6.6.1.1.3
slSonetPosMaxViolationThe Number of Maximum length violation packets.ro
Gauge32
.1.3.6.1.4.1.4515.1.6.6.1.1.4
slSonetPosRxfifoDiscardThe Number of packets discarded due to RXFIFO error.ro
Gauge32
.1.3.6.1.4.1.4515.1.6.6.1.1.5
slSonetPosPacketReceivedThe Number of packets received.ro
Counter64
.1.3.6.1.4.1.4515.1.6.6.1.1.6
slSonetPosPacketReceivedOkThe Number of error free packets.ro
Counter64
.1.3.6.1.4.1.4515.1.6.6.1.1.7
slSonetAls
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.6.7
slSonetAlsTableThe ALS configuration Table.
SEQUENCE OF SlSonetAlsEntry
.1.3.6.1.4.1.4515.1.6.7.1
slSonetAlsEntryThe entries exist for active sonet lines ifType = sonet(39). The objects in this table are used to configure the ALS algorithm.
SlSonetAlsEntry
.1.3.6.1.4.1.4515.1.6.7.1.1
slSonetAlsModeEnable/Disable the ALS algorithm. Note that the if the Laser Admin Status is 'down' the ALS mechanism is not operational.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.7.1.1.1
slSonetLosDeclareTimeTime to declare optical LOS present or clear: 550 +- 50 msec.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.7.1.1.2
slSonetTestPulseTimeManual restart for test Pulse time (in manual restart) - 90+-10 sec.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.7.1.1.3
slSonetManualPulseTimeManual restart Pulse time (in manual mode) - 2+-0.25 sec.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.7.1.1.4
slSonetAutomaticPulseTimeAutomatic restart Pulse time (in automatic mode) - 2+-0.25 sec.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.7.1.1.5
slSonetAutomaticDelayTimeIn Automatic mode. The delay between two laser re-activations.rw
INTEGER
.1.3.6.1.4.1.4515.1.6.7.1.1.6
slSonetLaserTestActivateActivate the laser for test operation.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.7.1.1.7
slSonetLaserManualActivateActivate the laser manual operation.rw
Enumeration
.1.3.6.1.4.1.4515.1.6.7.1.1.8
slSonetFs
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.6.8
slSonetFsTableThe frame structure configuration Table. In order to define a new path the NMS should create and configure an entry in this table. The table is also used to monitor the status of the LOP alarm per path.
SEQUENCE OF SlSonetFsEntry
.1.3.6.1.4.1.4515.1.6.8.1
slSonetFsEntryThe entries exist for sonet paths ifType = sonet(39). The objects in this table are used to configure the frame structure. Each OC-N line interface shall maintain a static table with number of lines equal to the N. Initially the table will be initialized to STS-Nc.
SlSonetFsEntry
.1.3.6.1.4.1.4515.1.6.8.1.1
slSonetFsIfIndexThe interface index.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.4515.1.6.8.1.1.1
slSonetFsStsThe number of the first STS in the path. Note that no all values are legal because there is no support for combus with mixed structurero
INTEGER
.1.3.6.1.4.1.4515.1.6.8.1.1.2
slSonetFsWidthThe number STS's in the path. The width is only valid for the first STS in the path. The other STSs of the path will have width=0.rw
INTEGER
.1.3.6.1.4.1.4515.1.6.8.1.1.3
slSonetFsFullPathTerminationFALSE - means partial path termination (only LOP alarm). TRUE - include full support for path Alarms and PM counters.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4515.1.6.8.1.1.4
slSonetFsGranularityThis value is set by the NMS according to the configured frame structure. Each VC-3 that is mapped to AUG-1 via VC-4 should have the value vc4(1). Otherwise the value should be vc3(2).rw
Enumeration
.1.3.6.1.4.1.4515.1.6.8.1.1.5
slSonetTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.6.11
slSonetFsTableChangeA slSonetFsTableChange trap is sent when the content of the slSonetFsTable is changed. This trap may be used by the NMS to identify the removal of path interfaces, or addition of new path interfaces
NOTIFICATION-TYPE
.1.3.6.1.4.1.4515.1.6.11.1
SL-SONET-MIB - SNMP MIB Reference | MIBs Explorer