SL-ROADM-MIB
The SL-ROADM-MIB module enables the monitoring and management of Reconfigurable Optical Add-Drop Multiplexer (ROADM) hardware, specifically tracking optical path states, port configurations, and attenuation levels within dense wavelength division multiplexing (DWDM) networks.
Imported Objects
Objects
35 total| Object Name |
|---|
slROADMThis MIB module describes the ROADM MODULE-IDENTITY .1.3.6.1.4.1.4515.1.1.16 |
slROADMConfig OBJECT IDENTIFIER .1.3.6.1.4.1.4515.1.1.16.1 |
slWSSConfigTableThe ROADM Configuration table. SEQUENCE OF SlWSSConfigEntry .1.3.6.1.4.1.4515.1.1.16.1.1 |
slWSSConfigEntryAn entry in the WSS Configuration table. SlWSSConfigEntry .1.3.6.1.4.1.4515.1.1.16.1.1.1 |
slWSSConfigLineIndexOnly one entry in the table.
Thus this is a dummy ifIndex that equals to 1.ro InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4515.1.1.16.1.1.1.1 |
slWSSConfigOperStatusThe WSS operational status. 0 - DOWN, 1 - UP.ro INTEGER .1.3.6.1.4.1.4515.1.1.16.1.1.1.2 |
slWSSConfigSwitchTempThe switch temperature in 0.1 celsiusro INTEGER .1.3.6.1.4.1.4515.1.1.16.1.1.1.3 |
slWSSConfigBoardTempThe board temperature in 0.1 celsiusro INTEGER .1.3.6.1.4.1.4515.1.1.16.1.1.1.4 |
slWSSConfigCaseTempThe case temperature in 0.1 celsiusro INTEGER .1.3.6.1.4.1.4515.1.1.16.1.1.1.5 |
slWSSConfigUptimeThe case temperature in 0.1 celsiusro INTEGER .1.3.6.1.4.1.4515.1.1.16.1.1.1.6 |
slWSSConfigComFirstWlThe channel numberrw INTEGER .1.3.6.1.4.1.4515.1.1.16.1.1.1.7 |
slWSSConfigComChCountThe overall count of channels in the Waveplan.
The channels are ordered in increasing frequency (decreasing wavelength).rw INTEGER .1.3.6.1.4.1.4515.1.1.16.1.1.1.8 |
slWSSConfigPowerLevelThe received Destination Access Point Identifier.ro INTEGER .1.3.6.1.4.1.4515.1.1.16.1.1.1.9 |
slWSSConfigAttenLevelThe received Source Access Point Identifier.ro INTEGER .1.3.6.1.4.1.4515.1.1.16.1.1.1.10 |
slWSSConfigEqualizationThreshLevelThe equalization threshold level.
In manual mode if the TX power is below this threshold an alarm is declared against this channel.
Legal values are -8dBm to -23dBm (default -13dBm).rw INTEGER .1.3.6.1.4.1.4515.1.1.16.1.1.1.11 |
slWSSConfigEqualizationMethodThe equalization method:
1 - manual equlization to predefined value (default mode).
2 - automatic equlizationrw Enumeration .1.3.6.1.4.1.4515.1.1.16.1.1.1.12 |
slWSSConfigSpacingThe spacing supported by the ROADM.ro Enumeration .1.3.6.1.4.1.4515.1.1.16.1.1.1.13 |
slROCHConfigTableThe ROADM Channel Configuration table. SEQUENCE OF SlROCHConfigEntry .1.3.6.1.4.1.4515.1.1.16.1.2 |
slROCHConfigEntryAn entry in the ROADM Configuration table. SlROCHConfigEntry .1.3.6.1.4.1.4515.1.1.16.1.2.1 |
slROCHConfigLineIndexThe ifIndex of the channel.
Channels 1-100 for the 100 GHz spacing cannels (e.g. 17 for CH17).
Channels 101-200 for the 50 GHz spacing channels (e.g. 117 for CH 17.5).ro InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4515.1.1.16.1.2.1.1 |
slROCHConfigProvisioningThe channel provisioningrw ROCHProvisioningType .1.3.6.1.4.1.4515.1.1.16.1.2.1.2 |
slROCHConfigInPowerLevelThe Power Level of the channel equal to Out Power Level + Attenuationro INTEGER .1.3.6.1.4.1.4515.1.1.16.1.2.1.3 |
slROCHConfigOutPowerLevelThe Output Power Level of the channelro INTEGER .1.3.6.1.4.1.4515.1.1.16.1.2.1.4 |
slROCHConfigChannelDetectChannel detect indication. 0 - not detected, 1 - channel is detectedro INTEGER .1.3.6.1.4.1.4515.1.1.16.1.2.1.5 |
slROCHConfigChPowerFailHighThreshThe threshold for channel High Power Failure.
Setting this value applies to all channels.rw INTEGER .1.3.6.1.4.1.4515.1.1.16.1.2.1.6 |
slROCHConfigChPowerFailLowThreshThe threshold for channel Low Power Failure.
Setting this value applies to all channels.rw INTEGER .1.3.6.1.4.1.4515.1.1.16.1.2.1.7 |
slROCHConfigChPowerDegHighThreshThe threshold for channel High Power Degrade.
Setting this value applies to all channels.rw INTEGER .1.3.6.1.4.1.4515.1.1.16.1.2.1.8 |
slROCHConfigChPowerDegLowThreshThe threshold for channel Low Power Degrade.
Setting this value applies to all channels.rw INTEGER .1.3.6.1.4.1.4515.1.1.16.1.2.1.9 |
slROCHConfigChPowerHystHighThreshThe threshold for channel High Power Hysteresis.
Setting this value applies to all channels.rw INTEGER .1.3.6.1.4.1.4515.1.1.16.1.2.1.10 |
slROCHConfigChPowerHystLowThreshThe threshold for channel Low Power Hysteresis.
Setting this value applies to all channels.rw INTEGER .1.3.6.1.4.1.4515.1.1.16.1.2.1.11 |
slROCHConfigChAliasThe alias for the channel. The dfault is the empty stringrw DisplayString .1.3.6.1.4.1.4515.1.1.16.1.2.1.12 |
slROCHConfigChAliasSmmThe alias for the channel as given by the SMM. The dfault is the empty stringrw DisplayString .1.3.6.1.4.1.4515.1.1.16.1.2.1.13 |
slROCHConfigProvisioningNewThe channel provisioning.
A bitmask with each bit for the corresponding port.
Bit n ON means that the channel is added/dropped from/to port number n+1.rw INTEGER .1.3.6.1.4.1.4515.1.1.16.1.2.1.14 |
slROADMPm OBJECT IDENTIFIER .1.3.6.1.4.1.4515.1.1.16.2 |
slROADMTraps OBJECT IDENTIFIER .1.3.6.1.4.1.4515.1.1.16.3 |
More MIBs from Argon
Browse all ArgonMIBs →SNMP MIB module
SNMP MIB module
SNMP MIB module
The SL-MAIN-MIB module provides SNMP access to monitor and manage the operational status, hardware health, and system resources of the main board on Schneider Electric (formerly Telemecanique) industrial automation controllers. It exposes critical metrics including CPU utilization, memory usage, temperature sensors, and power supply states to facilitate real-time fault detection and preventive maintenance.
SNMP MIB module
The SL-ETH-MIB module enables monitoring of Ethernet service parameters, specifically tracking interface statistics, service instance states, and traffic counters for SLA-compliant Ethernet services on Silex (or compatible) network equipment. It facilitates the verification of service connectivity and performance metrics required for SLA enforcement and fault isolation in carrier-grade Ethernet deployments.