Home/Catalog/SL-EDFA-MIB

SL-EDFA-MIB

AI MIB Summary

The SL-EDFA-MIB module enables SNMP-based monitoring and management of Erbium-Doped Fiber Amplifier (EDFA) optical line cards, specifically tracking optical power levels, gain status, pump laser currents, and alarm conditions to ensure signal integrity in fiber transport networks.

This MIB module describes the EDFA Cards
Main OID:
slEdfa.1.3.6.1.4.1.4515.1.9
46
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

46 total
Object Name
slEdfaThis MIB module describes the EDFA Cards
MODULE-IDENTITY
.1.3.6.1.4.1.4515.1.9
edfaConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.9.1
edfaConfigTableThe EDFA configuration table.
SEQUENCE OF EdfaConfigEntry
.1.3.6.1.4.1.4515.1.9.1.1
edfaConfigEntryAn entry in the EDFA interface configuration table. The index to this table is the same as the an ifIndex.
EdfaConfigEntry
.1.3.6.1.4.1.4515.1.9.1.1.1
edfaIfIndexThe amplifier interface index.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.4515.1.9.1.1.1.1
edfaPumpTempThe pump temperture (in Kelvin).ro
Integer32
.1.3.6.1.4.1.4515.1.9.1.1.1.2
edfaRxPowerThe measured Rx Power. The value is specified in ten'th of Dbm units increments, starting from -30.0 dbm (e.g. value 0 means -30.0 dbm).ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.3
edfaPumpAdminStatusThe desired state of the laser. The restart(3) state indicates that the edfa pump should be restarted. The restart(3) is not a state, thus it is not kept in the configuration file.rw
Enumeration
.1.3.6.1.4.1.4515.1.9.1.1.1.4
edfaPumpOperStatusThe current operational state of the laser. If edfaPumpAdminStatus is down(2) then edfaPumpOperStatus should be down(2). If edfaPumpAdminStatus is changed to up(1) then edfaPumpOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic; it should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state. The operational status is equal to restart(3) if the edfa pump is still in restart process.ro
Enumeration
.1.3.6.1.4.1.4515.1.9.1.1.1.5
edfaStatusThis variable indicates the Line Status of the Edfa module. The edfaStatus is a bit map represented as a sum, therefore, it can represent multiple failures (alarms) simultaneously. edfaNoAlarm must be set if and only if no other flag is set. The various bit positions are: 1 edfaNoAlarm No alarm present 2 edfaPumpTemperuture Pump temperatur is out-of-bound 4 edfaPumpWavelength Pump wavelength is out-of-bound 8 edfaHwFail Pump HW failure 16 edfaRvcSignalDetect Loss of input signal 32 edfaPumpPower Pump power is out-of-bound 64 edfaRcvPower Rx Power is out-of-bound 128 edfaTemprature Edfa temperature is out-of-bound 256 edfaEyeSafty Eye safety alarm (available only in eye-safety mode) 512 edafGainFlatness Gain flatness alarm 1024 edfaXmtPower Tx Power is out-of-bound 2048 edfaGain Edfa Gain is out-of-bound 4096 edfaEol Pump End Of Lifero
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.6
edfaVoaThe computed VOA output attenuation specified in 0.1 dB units. From 0.0 to +15.0 dB.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.7
edfaAutomaticModeDefines the Edfa automatic mode. If equals TRUE, the Edfa control mode should selected automaticaly. Otherwise it should be selected manualy.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4515.1.9.1.1.1.8
edfaAdminControlModeConfigure the Edfa control mode. This object may be set only when edfaAtomaticMode is FALSE.rw
Enumeration
.1.3.6.1.4.1.4515.1.9.1.1.1.9
edfaOperControlModeThe current Edfa control mode. Initialy the Edfa starts in APC mode. The AGC mode is used only when selected manualy or after transient input power change.ro
Enumeration
.1.3.6.1.4.1.4515.1.9.1.1.1.10
edfaAdminGainThe required Edfa Gain value given in 0.1 dB units. This value may be configured only when the edfa automatic mode is FALSE and the edfa control mode is Agc.rw
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.11
edfaOperGainThe actual Edfa Gain value given in 0.1 dB units. Value range starts with 0.0 dbmro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.12
edfaAdminOutputPowerThe required Edfa output power value given in 0.1 dBm units. The range starts with -30.0 dBm. This value may be configured only when the edfa control mode is Apc.rw
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.13
edfaOperOutputPowerThe actual Edfa total output power value specified in 0.1 dBm units. Valid valuse are in the range of 0.0 dBm upto +15.0 dBm.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.14
edfaChannelsNumberThe number of optical channels on this signal.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.15
edfaTotalChannelsNumberThe total number of optical channels on this fiber.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.16
edfaEyeSafetyModeWhen in Eye-Safety mode the edfa reduces the laser power budget down to safe level upon detection of an output fiber cut.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4515.1.9.1.1.1.17
edfaShutDownLipEnableEDFA shout-down on LIP (Loss of signal) - enable/disable.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4515.1.9.1.1.1.18
edfaAutoPowerUpLipEnableEDFA automatic power up (after signal returns) - enable/disable.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4515.1.9.1.1.1.19
edfaMaxGainThe EDFA max gain is determined by the result of the VER command. Legal values: gainUnknown(1) gain14dbm(2) - Booster/Inline, (-2)-14dBm output power, gain (-5)-22dB gain17dbm(3) - Booster/Inline, (-2)-17dBm output power, gain (-5)-22dB gain20dbm(4) - Booster/Inline, (-2)-20dBm output power, gain (-5)-22dB gain23dbm(5) - Booster/Inline, 5-23dBm output power, gain (-5)-22dB, 16 channels gain18dbmPreAmp8Ch(6) - Preamp (-18)-5dBm output power, fixed gain 18dB gain18dbmPreAmp16ChRed(7) - Preamp (-18)-5dBm output power, fixed gain 18dB gain18dbmPreAmp16ChBlue(8)- Preamp (-18)-0dBm output power, fixed gain 18dB gain23dbmGain10(9) - Booster/Inline, 23dBm output power with fixed gain of 10dB, 32 channelsro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.20
edfaGainInFromLower input gain range of the edfa in units of 0.1 db.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.21
edfaGainInToUpper input gain range of the edfa in units of 0.1 db.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.22
edfaGainOutFromLower output gain range of the edfa in units of 0.1 db.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.23
edfaGainOutToUpper output gain range of the edfa in units of 0.1 db.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.24
edfaPowerInFromLower input power range of the edfa in units of 0.1 dbm.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.25
edfaPowerInToUpper input power range of the edfa in units of 0.1 dbm.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.26
edfaPowerOutFromLower output power range of the edfa in units of 0.1 dbm.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.27
edfaPowerOutToUpper output power range of the edfa in units of 0.1 dbm.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.28
edfaFromChannelThe first channel number supported by the edfa; 0 to ignore.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.29
edfaToChannelThe last channel number supported by the edfa; 0 to ignore.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.30
edfaOscChannelThe wavelenght of the optical supervisory channel e.g. 1510, 1490.ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.31
edfaRedBlueTypeThe type of the edaf.ro
Enumeration
.1.3.6.1.4.1.4515.1.9.1.1.1.32
edfaRoleThe role of the edaf.ro
Enumeration
.1.3.6.1.4.1.4515.1.9.1.1.1.33
edfaFreeDescriptionA free text with additional edfa information.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4515.1.9.1.1.1.34
edfaConfigSafetyThresholdThe Eye Safety threshold level specified in dBm units. The value given in 0.1 dBm units. The range starts with -50.0 dBm.rw
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.35
edfaSigOutputPowerThe measured Signal output Power. The value is specified in ten'th of Dbm units increments, starting from -30.0 dbm (e.g. value 0 means -30.0 dbm).ro
INTEGER
.1.3.6.1.4.1.4515.1.9.1.1.1.36
edfaTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.9.2
edfaTraps0
OBJECT IDENTIFIER
.1.3.6.1.4.1.4515.1.9.2.0
edfaStatusChange0A edfaStatusChange trap is sent when the value of an instance edfaStatus changes. It can be utilized by an NMS to trigger polls. It is defined to support browsers that don't recognize RFC 2576.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4515.1.9.2.0.1
edfaControlModeChange0A edfaControlModeChange trap is sent when the value of an instance edfaOperControlMode when going from APC to AGC (both directions) in automatic mode. It is defined to support browsers that don't recognize RFC 2576.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4515.1.9.2.0.2
edfaStatusChangeA edfaStatusChange trap is sent when the value of an instance edfaStatus changes. It can be utilized by an NMS to trigger polls.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4515.1.9.2.1
edfaControlModeChangeA edfaControlModeChange trap is sent when the value of an instance edfaOperControlMode when going from APC to AGC (both directions) in automatic mode.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4515.1.9.2.2
SL-EDFA-MIB - SNMP MIB Reference | MIBs Explorer