SL-CHASSIS-MIB
The SL-CHASSIS-MIB monitors multi-chassis system topology, chassis status, and hardware component states (such as power supplies, fans, and line cards) within SL (likely Silex or a specific vendor's) network equipment to facilitate centralized management of redundant or clustered hardware environments.
Imported Objects
Objects
27 total| Object Name |
|---|
slChassisThis MIB module describes the Multi-Chassis information MODULE-IDENTITY .1.3.6.1.4.1.4515.1.3.18 |
slChassisInfo OBJECT IDENTIFIER .1.3.6.1.4.1.4515.1.3.18.1 |
slChassisInfoNodeSlotIdThe slot ID of the node.
This number is assigned to the node before it is a part of the chassis.
Slot ID should be assigned also to the GNE nodes.
The Slot ID should be unique in the chassis.rw INTEGER .1.3.6.1.4.1.4515.1.3.18.1.1 |
slChassisInfoNodeRoleThe role of the node.
gneNode - for Master or Backup chassis GNE node.
internalSlotNode - for non gne node.
none - the node is in a simple chassisrw Enumeration .1.3.6.1.4.1.4515.1.3.18.1.2 |
slChassisInfoLanVrrpIpThe VRRP ip of the node on the LAN interface.rw IpAddress .1.3.6.1.4.1.4515.1.3.18.1.3 |
slChassisInfoOscVrrpIpThe VRRP ip of the node on the OSC interface.rw IpAddress .1.3.6.1.4.1.4515.1.3.18.1.4 |
slChassisInfoTopologyThe topology mode of the multichassis:
osc - the management use the LAN IP of the GNE and VRRP.
lan - the management use the OSC IP of the GNE and VRRP.
simple - no GNE to the chassis. Used for display onlyrw Enumeration .1.3.6.1.4.1.4515.1.3.18.1.5 |
slChassisInfoVrrpEnableEnable/Disable the activation of the VRRP protocol by the GNErw Enumeration .1.3.6.1.4.1.4515.1.3.18.1.6 |
slChassisSlot OBJECT IDENTIFIER .1.3.6.1.4.1.4515.1.3.18.2 |
slChassisSlotTableThis table contains the chassis slots. SEQUENCE OF SlChassisSlotEntry .1.3.6.1.4.1.4515.1.3.18.2.1 |
slChassisSlotEntryAn entry in the Chassis Slot table. SlChassisSlotEntry .1.3.6.1.4.1.4515.1.3.18.2.1.1 |
slChassisSlotIdThe slot ID of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.1 |
slChassisSlotRoleThe role of the node.
gneNode - for Master or Backup chassis GNE node.
internalNode - for non gne nodero Enumeration .1.3.6.1.4.1.4515.1.3.18.2.1.1.2 |
slChassisSlotInternalIpThe internal ip of the node.
This address is used to identify the node and not for management access.ro IpAddress .1.3.6.1.4.1.4515.1.3.18.2.1.1.3 |
slChassisSlotProductTypeThe sysObjectID of the node.ro OBJECT IDENTIFIER .1.3.6.1.4.1.4515.1.3.18.2.1.1.4 |
slChassisSlotSysNameThe SysName of the nodero DisplayString .1.3.6.1.4.1.4515.1.3.18.2.1.1.5 |
slChassisSlotSnmp161PortThe SNMP Gte/Set port of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.6 |
slChassisSlotSnmp162MinPortThe minimal SNMP Trap port of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.7 |
slChassisSlotSnmp162MaxPortThe maximal SNMP Trap port of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.8 |
slChassisSlotHttpPortThe HTTP port of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.9 |
slChassisSlotTelnetPortThe Telnet port of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.10 |
slChassisSlotFtpPortThe Ftp port of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.12 |
slChassisSlotTL1PortThe TL1 port of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.13 |
slChassisSlotPingIdentifierThe ping identifier of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.14 |
slChassisSlotHttpsPortThe HTTPS port of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.15 |
slChassisSlotSshPortThe SSH port of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.16 |
slChassisSlotSTL1PortThe TL1 over SSH port of the node.ro INTEGER .1.3.6.1.4.1.4515.1.3.18.2.1.1.17 |
More MIBs from Argon
Browse all ArgonMIBs →SNMP MIB module
SNMP MIB module
SNMP MIB module
The SL-MAIN-MIB module provides SNMP access to monitor and manage the operational status, hardware health, and system resources of the main board on Schneider Electric (formerly Telemecanique) industrial automation controllers. It exposes critical metrics including CPU utilization, memory usage, temperature sensors, and power supply states to facilitate real-time fault detection and preventive maintenance.
SNMP MIB module
The SL-ETH-MIB module enables monitoring of Ethernet service parameters, specifically tracking interface statistics, service instance states, and traffic counters for SLA-compliant Ethernet services on Silex (or compatible) network equipment. It facilitates the verification of service connectivity and performance metrics required for SLA enforcement and fault isolation in carrier-grade Ethernet deployments.