Home/Catalog/SHE-PHYSICAL-MIB

SHE-PHYSICAL-MIB

AI MIB Summary

The SHE-PHYSICAL-MIB facilitates the monitoring of physical layer attributes and logical entity states for SHE (Secure High-speed Ethernet) equipment, enabling granular visibility into interface status, port configurations, and hardware health metrics within the SHE management architecture.

The MIB module for representing multiple logical entities for the SHE Equipment management.
Main OID:
shePhysical.1.3.6.1.4.1.231.7.1.2.2.1.1
254
Objects
Active
Status
9
Dependencies

Imported Objects

Objects

254 total
Object Name
shePhysicalThe MIB module for representing multiple logical entities for the SHE Equipment management.
MODULE-IDENTITY
.1.3.6.1.4.1.231.7.1.2.2.1.1
shePhysContainerObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.1
shePhysContainerTableThe container/slot table.
SEQUENCE OF ShePhysContainerEntry
.1.3.6.1.4.1.231.7.1.2.2.1.1.1.1
shePhysContainerEntryEntry of the container table. The entries represent the slots of a SHE shelf
ShePhysContainerEntry
.1.3.6.1.4.1.231.7.1.2.2.1.1.1.1.1
shePhysContainerAccCardTypesThis attribute identifies the types of plug-in units to be accepted by this slot. The strings are separated by newline characters. That means CR LF. Valid strings are: emptyCardType Central cards (support depend on NE release and used shelf): CXUGE:4E:E CXUCGE:4E:E CXUB1GE:4E:E CXUB2GE:4:E CXUC2GE:4:E CXUB3GE:4:E CXUB21GE:4:E CXUG1B:2O:4E:E (>=3.7M) DSL IU card's (support depend on used NE release): IUSHDSL:48S:E IUSHDSL:48B:E IUADSL:48P:E IUADSL:72A:E IUADSL:72B:E (obsolete) IUADSL:72P:IFX IUADSL:72I:IFX IUADSL:72AI:WC IUADSL:72AJ:WC IUVDSL:24D:IFX IUVDSL:24D2:IFX IUADSL:72A:CG IUADSL:72B:CG IUVDSL:24P:E IUVDSL:48P:E IUVDSL:48I:E (obsolete) IUADSL:72A:CGH IUADSL:72B:CGH IUADSL:72J:CGH IUSHDSL:48E:E IUSHDSL:48E:8Q:E (>=R2.8 maintenance) IUVDSL:48I2:E (>=R2.8) IUVDSL:48P2:E (>=R2.8) IUSHDSL:48E:ME:E (>=R3.7M) IUADSL:72B:M:CG (>=R3.7M) IUADSL:72B:ME:CG (>=R3.7M) IUADSL:72J:ME:CG (>=R3.7M) IUVDSL:48I3:M:E (>=R3.7M) IUVDSL:48I3:ME:E (>=R3.7M) IUVDSL:48J3:ME:E (>=R3.7M) Subtending card (with R3.7M also used as UNI card): IU1GE:10O:SYN:E VoIP-Cards (only supported if NE support VoIP at all): VPLU-S72-POTS:E IU:32I4:E IU:32I2:E VPLU:72P:E VPLU:72P1:E (>=R2.8M) VPLU:72P2:E (>=R2.8M) Powermodules (support depend on NE release and used shelf): PM1:E PM2:E PM3:A PM:UPL:E PM:UPL:R:E PM:UPL:A PM1:R:E PM1:R:A PM:R:A Powermodules for new shelftypes 2. generation -> 2G (>= R2.8 maintenance): PM:UPL:2G:E PM:UPL:2G:A PM1:R:2G:E PM:R:2G:E PM:R:2G:A PM:ONU:2G:E Boards for hiX5622 R1.0: (obsolete because release was canceled) CXUMGE:4:E SBXDSL:16P:E SBXDSL:16:E Board for hiX5608 (MiniIPD): HIX5608:Ero
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.1.1.1.1
shePhysContainerSlotStatusIndicates whether a slot is empty or used.ro
ShePhysSlotStatusType
.1.3.6.1.4.1.231.7.1.2.2.1.1.1.1.1.4
shePhysContainerConfiguredCardTypeThis attribute identifies the card type configured for this slot. Valid strings for card types are according to content of shePhysContainerAccCardTypes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.231.7.1.2.2.1.1.1.1.1.5
shePhysContainerPluggedCardTypeThis attribute identifies the card type plugged for this slot. Valid strings for card types are according to content of shePhysContainerAccCardTypes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.231.7.1.2.2.1.1.1.1.1.6
shePhysCardObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.2
shePhysCardTableTable containing the plug-in unit entries.
SEQUENCE OF ShePhysCardEntry
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1
shePhysCardEntryEntry of shePhysCardTable. Each entry is used to represent a card independently whether it is present or not (feature offline configuration). Cards can be created either by auto-configuration (plug-in) or by user command. Notifications : shePhysStateChangeOper. shePhysStateChangeAdmin. shePhysCardCreated. shePhysCardDeleted. Alarm traps when a fault has been detected or cleared.
ShePhysCardEntry
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1
shePhysCardAdminStateThis attribute shows the administrative state of the plugin unit. In the transition from lock to unlock the plug-in unit is diagnosed. Default is notEquipped except for controller cards. The AdminState of controller cards is always unlocked. Planned is very similar to the locked state. Planned is used for configuration of cards without having a card equipped. A correct card being plugged leads to an auto-configuration of the card: the AdminState changes automatically from planned to unlocked.ro
ShePhysCardAdminStateType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.1
shePhysCardAvailStateThe availability state of a card.ro
ShePhysAvailabilityStateType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.2
shePhysCardOperStateThe operational state of a card.ro
ShePhysCardOperStateType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.3
shePhysCardProtCapabilityThe protection modes the card can work: -bit0=1: Card can work as standalone card. -bit1=1: Card can work as standby card.ro
ShePhysProtectionCapabilityType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.4
shePhysCardProtModeThe redundancy mode the card is running. -standaloneCard: The card works as standalone board. No redundancy is supported. -protectionCard: The card works in redundancy mode.ro
ShePhysProtectionModeType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.5
shePhysCardProtDefaultRoleDefines the default role of the card (e.g. after power on) if more than one card which belong to the same protection group are become availible at the same time. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard. -working: The card becomes the active card by default. -protecting: The card becomes the standby card by default.ro
ShePhysDefaultRoleType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.6
shePhysCardProtDynamicRoleThe dynamic role of card. Note, this attribute is only valid if shePhysCardProtMode = protectionCard. -active: The card is the active card. -standby: The card is the standby card. -notDefined: If there is no card plugged, it is not possible to say which card will become the active or standby card.ro
ShePhysDynamicRoleType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.7
shePhysCardProtGroupIdThe ID of protection group this card belongs to. Cards with the same Id can protect each other. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard.ro
INTEGER
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.8
shePhysCardProtStateThe current state of the protection: -unknown If the dynamic role of the cards which belong to a protection group is not set yet, there is no information about the protection state available. -active_noRedundancy: The card is the active card but is not protected by a standby card. -active_protected: The card is the active card is is protected by a standby card. -active_degraded: The card is the active card but not all functionality is protected by the standby card. -standby_notPresent: The card is the standby card but it is not available. -standby_booting: The card is the standby card but is still booting. -standby_protecting: The card is the standby card and protects the active card. -standby_degraded: The card is the standby card but can not take over all functionality of the current active board. Note, this attribute is only valid if shePhysCardProtCapability = protectionCard.ro
ShePhysProtState
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.9
shePhysCardAlarmSeverityIndexIt is a pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1.ro
SheAlarmSevProfileIndex (SHE-ALARMING-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.10
shePhysCardUpgradeStateInforms about the state of the SW upgrade task during loading and the result at the end of loading the current plug-in unit. NOTE: The parameter is set to obsolete state with R3.7M. Also former releases does not report a valid information on this parameter. Valid informations about SW upgrade could only be retrieved via sheSystemSwMaintenanceTaskTable.roobsolete
ShePhysUpgradeStateType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.11
shePhysCardSwRunningLoadInforms about the currently running load.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.12
shePhysCardSwStoredLoadInforms about the currently stored load.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.13
shePhysCardTemperatureCurrentCurrent temperature of a card - 255 means unknown value.ro
INTEGER (-40..200 | 255) UNITS "C"
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.1.1.14
shePhysCardControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2
shePhysCardControlRequestThe card commands : changeAdminState: changes the shePhysCardAdminState of a card. AdminState of controller cards cannot be changed. changeAlarmSeverityProfile: changes the shePhysCardAlarmSeverityIndex of a card. This is the pointer to a alarm severity profile. createCard: creates plugin units. Acceptable in state NotEquipped and when object does not exist. The AdminState after creation, possible values are Planned or Locked, is specified as command parameter. The command is not accepted for CXUs. These HW objects are automatically created. The acceptable CardTypes are specified in the slot attribute shePhysContainerAccCardTypes. The content of this attribute changes after the creation to values allowed for the convert command. deleteCard: deletes a card. Acceptable only in state Planned/Locked. The command is not accepted for CXUs. CXUs are automatically deleted when board redundancy is disabled. The AdminState changes to NotEquipped. convertCard: converts the type of card. Acceptable only within the same card group, e.g. ADSL to ADSL according to content of types listed in shePhysContainerAccCardTypes. convertCard allowed in state Planned/Locked. Notifications: shePhysCardControlResult when a command has finished. reset commands: resetSystem: reset of system (all cards) and activates loads after SW download. The main card will perform a restart. resetSystemWithDefaultConf : restart with default configuration is performed. resetCard: after SW download to activate the new load of a specific card. resetCardAllOfType: after SW download of cards of the same type to activate the new load. Notifications : shePhysCardReset at beginning of reset. shePhysCardResetEnd at end of reset. shePhysCardControlResult for reset of CXU in case of a failure occured after the reset has been accepted. changeAlarmSeverityProfile: the alarm severity profile is changed for a specific card. THIS REQUEST WILL NOT LONGER BE SUPPORTED BY NE R2.5: setTemperatureThreshold: configure the temperature threshold which is used. When temperature reaches the threshold, alarm is turned on.rw
ShePhysCardControlRequestType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.1
shePhysCardControlStatusThe status of a user command.ro
SheControlStatusType (SHE-TC-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.2
shePhysCardControlPhysicalNameA valid string for a card. Identifies the type of card which should be created. Default is \0.rw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.3
shePhysCardControlContainedInIndexThe entPhysicalIndex of the slot which contains the card.rw
PhysicalIndex (ENTITY-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.4
shePhysCardControlTimerThe maximum wait time for the manager for a long running user command.ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.5
shePhysCardControlReqResultThe result of the last user command.ro
ShePhysCardControlRequestResultType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.6
shePhysCardControlTimeStampThe time stamp of the last command (end of command).ro
Unsigned32 UNITS "sec"
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.7
shePhysCardControlAdminStateChangeSelects the desired adminstrative state.rw
ShePhysAdminStateChangeType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.8
shePhysCardControlAdminStateCreateSelects the desired adminstrative state in user command createCard.rw
ShePhysAdminStateCreateType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.9
shePhysCardControlTemperatureThresholdThe temperature threshold for all cards. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5.rwobsolete
INTEGER (-40..200) UNITS "C"
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.10
shePhysCardControlEntPhysicalIndexThe entPhysicalIndex of the plugin unit which should get the reset.rw
PhysicalIndex (ENTITY-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.13
shePhysCardControlAlarmSeverityIndexThe new AlarmSeverityIndex of the alarm severity profile assigned to the card.rw
SheAlarmSevProfileIndex (SHE-ALARMING-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.2.14
sheTemperatureObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3
shePhysCardTemperaturePowerDownOnTemperature threshold for generation of shePhysCardTemperaturePowerDown alarm for line cards. IU will start now with action to reduce power consumption.ro
INTEGER
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.1
shePhysCardTemperaturePowerDownOffTemperature threshold for clearing of shePhysCardOverTemperatureReset alarm for the line cards.ro
INTEGER
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.2
shePhysCardOverTemperatureResetOnTemperature threshold for the generation of the shePhysCardOverTemperatureReset alarm for line cards. CXU has forced IU tp reset state, to prevend from further damages.ro
INTEGER
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.3
shePhysCardOverTemperatureResetOffTemperature threshold for the clearing the shePhysCardOverTemperatureReset alarm for line cards.ro
INTEGER
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.4
shePhysCardTemperatureThresholdTHIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5. Temperature threshold for all cards of shePhysCardOverTemperatureThreshold.roobsolete
Integer32 (-40..200) UNITS "C"
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.5
shePhysCardTemperatureWarningOnTemperature threshold for generation of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions.ro
INTEGER (-40..120) UNITS "C"
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.6
shePhysCardTemperatureWarningOffTemperature threshold for clearing of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions.ro
INTEGER (-40..120) UNITS "C"
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.7
sheTemperatureControlObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10
shePhysCardTemperatureControlRequestThe card commands : changeTemperatureWarningThreshold: changes the shePhysCardTemperatureWarningThreshold's.rw
ShePhysControlRequestType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.1
shePhysCardTemperatureControlStatusThe status of a user command.ro
SheControlStatusType (SHE-TC-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.2
shePhysCardTemperatureControlTimerThe maximum wait time for the manager for a long running user command.ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.3
shePhysCardTemperatureControlReqResultThe result of the last user command.ro
ShePhysCardControlRequestResultType
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.4
shePhysCardTemperatureControlTimeStampThe time stamp of the last command (end of command).ro
Unsigned32 UNITS "sec"
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.5
shePhysCardTemperatureControlWarningOnTemperature threshold for generation of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions.rw
INTEGER (-40..120) UNITS "C"
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.6
shePhysCardTemperatureControlWarningOffTemperature threshold for clearing of shePhysCardTemperatureWarning alarm for line cards. The NE will not start any actions in that case. It is only warning for changed temperature conditions.rw
INTEGER (-40..120) UNITS "C"
.1.3.6.1.4.1.231.7.1.2.2.1.1.2.3.10.7
shePhysPortObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.3
shePhysPortTableThe port table extension of the IfTable. Provides the mapping information concerning port and card the port is contained and the alarm severity profile.
SEQUENCE OF ShePhysPortEntry
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.1
shePhysPortEntryEntry of the port table. Represents a physical interface (a port).
ShePhysPortEntry
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1
shePhysPortEntPhysicalIndexThe entPhysical index of the card this port is contained in.ro
PhysicalIndex (ENTITY-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.1
shePhysPortIdThe port number/port ID related to the card this port is contained in.ro
INTEGER
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.2
shePhysPortAlarmSeverityIndexA pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1.ro
SheAlarmSevProfileIndex (SHE-ALARMING-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.3
shePhysPortUserLabelPort specific ASCII identification. This string is only used by the ACI to identifying a physical UserPort. The data is stored in NE but has no further meaning for the NE himself.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.4
shePhysPortAdminStateLastChangeTimeThe timestamp when this port last times changes adminstate. New parameter with SHE R2.8 maintenance.ro
Unsigned32 UNITS "sec"
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.5
shePhysPortOperStateUpLastChangeTimeThe timestamp when this port last times reaches operstate UP. New parameter with SHE R2.8 maintenance.ro
Unsigned32 UNITS "sec"
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.6
shePhysPortOperStateDownLastChangeTimeThe timestamp when this port last times reaches operstate DOWN. New parameter with SHE R2.8 maintenance.ro
Unsigned32 UNITS "sec"
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.1.1.7
shePhysPortControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.2
shePhysPortControlRequestThe port commands : changeAdminState: the AdminState of the current port shall be changed. changeAlarmSeverityProfile: the alarm severity profile of the port is changed. resetStatisticCounters: reset all statistic counters in if- and ifx-table for this port. changeUserLabel: change the value of the UserLabel for this port. changeOperStateTrapEnablePermission: change the permission to send operstate trap for this port. Notifications : shePhysPortControlResult at the command ending in case of long running command.rw
ShePhysPortControlRequestType
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.1
shePhysPortControlStatusThe status of a user command.ro
SheControlStatusType (SHE-TC-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.2
shePhysPortControlIfIndexThe IfIndex of the port that shall be configured.rw
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.3
shePhysPortControlAlarmSeverityIndexThe new AlarmSeverityIndex of the alarm severity profile assigned to the port.rw
SheAlarmSevProfileIndex (SHE-ALARMING-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.4
shePhysPortControlAdminStateThe desired AdminState of the port that shall be configured.rw
SheAdminStateType (SHE-TC-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.5
shePhysPortControlTimeStampThe time stamp of the last command (end of command).ro
Unsigned32 UNITS "sec"
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.6
shePhysPortControlTimerThe maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysRiResult .ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.7
shePhysPortControlReqResultThe result of the last user command.ro
ShePhysPortControlRequestResultType
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.8
shePhysPortControlUserLabelPort specific ASCII identification. This string is only used by the ACI to identifying a physical UserPort. The data is stored in NE but has no further meaning for the NE himself.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.9
shePhysPortControlOperStateTrapEnableEnable/disable OperStateTrap's. Current status could be read from ifx-table.rw
ShePermissionType (SHE-TC-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.2.10
shePhysPortNEInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.3
shePhysPortAdslCountThis attribute returns the current number of available physical port's of type ADSL (ifType 94) of the NE. The attribute could be used by the management system for licensing.ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.1
shePhysPortShdslCountThis attribute returns the current number of available physical port's of type SHDSL (ifType 96) of the NE. The attribute could be used by the management system for licensing.ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.2
shePhysPortVdslCountThis attribute returns the current number of available physical port's of type VDSL (ifType 97) of the NE. The attribute could be used by the management system for licensing.ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.3
shePhysPortAdsl2CountThis attribute returns the current number of available physical port's of type ADSL2 (ifType 230) of the NE. The attribute could be used by the management system for licensing.ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.4
shePhysPortVoipCountThis attribute returns the current number of available physical port's of type VOIP (ifType 104) of the NE. The attribute could be used by the management system for licensing.ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.5
shePhysPortIsdnCountThis attribute returns the current number of available physical port's of type ISDN (ifType 63) of the NE. The attribute could be used by the management system for licensing.ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.3.3.6
shePhysRedundancyObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.4
shePhysBoardRedundancyControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.4.1
shePhysBrdControlRequestThe user commands for board redundancy and switch over. enableBoardRedundancy, disableBoardRedundancy: to enable/disable board redundancy. boardSwitchOver: applicable when board redundancy is enabled and the standby board is in the state ShePhysCardProtState = standby_protecting (There is no traffic interruption in case of swithover.) boardSwitchOverForced: applicable when board redundancy is enabled, ShePhysCardProtState = standby_protecting or standby_degraded. modifyRedundancyFeature: applicable only for CXU-board modifyRedundancyInterlinksFeature: applicable only for CXU-boardrw
ShePhysBrdControlRequestType
.1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.1
shePhysBrdControlStatusThe status of the control request.ro
SheControlStatusType (SHE-TC-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.2
shePhysBrdControlReqResultThe result of the last user command.ro
ShePhysBrdControlRequestResultType
.1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.3
shePhysBrdControlTimeStampThe time stamp of the last command (end of command).ro
Unsigned32 UNITS "sec"
.1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.4
shePhysBrdControlTimerThe maximum wait time for the manager for a line redundancy user command.ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.5
shePhysBrdControlEntPhysicalIndexThe entPhysicalIndex of the card to be switched over or modified.rw
PhysicalIndex (ENTITY-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.6
shePhysBrdControlRedundancyFeatureOnly applicable for CXU-board.rw
ShePhysRedundancyFeatureType
.1.3.6.1.4.1.231.7.1.2.2.1.1.4.1.7
shePhysRedundancyBase
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.4.2
shePhysRedundancyFeatureConfigure special features they are importend for redundancy handling.ro
ShePhysRedundancyFeatureType
.1.3.6.1.4.1.231.7.1.2.2.1.1.4.2.1
shePhysicalNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.5
shePhysRackEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.1
shePhysRackControlResultNotification of rack command ending and result.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.1.1
shePhysRackAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.2
shePhysDCAlarm0Break down of power supply fan group 0 .
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.1
shePhysDCAlarm1Break down of power supply fan group 1 .
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.2
shePhysFanAlarm0Depending on used shelftype the alarm stand for: M400, M600, M1200, MDUS: -> Alarm for Fan 0. G100 G200 G400, G600, M1100, G1100: -> Fan control defective.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.3
shePhysFanAlarm1Depending on used shelftype the alarm stand for: M400, M600, M1200, MDUS: -> Alarm for Fan 1. G100 G200 G400, G600, M1100, G1100: -> Fan defective (Sum alarm).
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.4
shePhysFanAlarm2Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 2. G100 G200 G400, G600, M1100, G1100: -> Filter pad must be cleaned. MDUS: -> not used.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.5
shePhysFanAlarm3Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 3. G100 G200 G400, G600, M1100, G1100, MDUS: -> not used
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.6
shePhysFanAlarm4Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 4 (if equiped). G100 G200 G400, G600, M1100, G1100, MDUS: -> not used
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.7
shePhysFanAlarm5Depending on used shelftype the alarm stand for: M400, M600, M1200: -> Alarm for Fan 4 (if equiped). G100 G200 G400, G600, M1100, G1100, MDUS: -> not used
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.2.8
shePhysShelfEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.3
shePhysShelfControlResultNotification of chassis command ending and result.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.3.1
shePhysShelfControlExternalAlarmsConfigurationChangedExternal alarm configuration changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.3.2
shePhysShelfControlRelativeHumidityAlarmThresholdChangedAlarm threshold configuration changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.3.3
shePhysShelfBatteryBackupModifiedCould only occur in shelf SHE hiX5622 R1.0 -> MDUS:E, if battery backupMode was modified.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.3.4
shePhysShelfControlExternalAlarmsOutputStatusChangedExternal alarm output status configuration changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.3.5
shePhysShelfAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4
shePhysShelfMupState1Break down of redundancy power supply 1 ( Power Supply or battery ). Note: This alarm will never occur in case of used shelftype G400R/G600:R:E with plugged PM_R module.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.1
shePhysShelfMupState2Break down of redundancy power supply 2 ( Power Supply or battery ). Note: This alarm will never occur in case of used shelftype G400R/G600:R:E with plugged PM_R module.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.2
shePhysShelfExternalAlarm01External Alarm 01. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): AC Failure -> Powering Alarm - Loss of external power.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.3
shePhysShelfExternalAlarm02External Alarm 2. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): DC Failure (internal fault) -> Equipment Alarm - A functional failure on an internal interface.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.4
shePhysShelfExternalAlarm03External Alarm 3. Default usage in hix5622 system R1.0 (shelftyp MDUS:E): Deep battery discharge -> Battery Low - battery is provisioned and present but voltage is too low.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.5
shePhysShelfExternalAlarm04External Alarm 4. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery missing -> Battery is provisioned but missing.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.6
shePhysShelfExternalAlarm05External Alarm 5. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery replace (end of life) -> Battery Failure - Battery is provisioned and present but cannot recharge.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.7
shePhysShelfExternalAlarm06External Alarm 6. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Door Contact -> Physical Intrusion alarm.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.8
shePhysShelfExternalAlarm07External Alarm 7.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.9
shePhysShelfExternalAlarm08External Alarm 8.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.10
shePhysShelfRelativeHumidityAlarmThe configured threshold for relative humidity was reached.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.11
shePhysShelfHeatExchangerInBreak down of 1 or more fan of the heat exchanger inner circle. Note: This alarm could only occur in case of used shelftype G400R/G600:R:E with plugged PM_R module.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.12
shePhysShelfHeatExchangerOutBreak down of 1 or more fan of the heat exchanger outer circle. Note: This alarm could only occur in case of used shelftype G400R/G600:R:E with plugged PM_R module.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.13
shePhysShelfExtAlarmCollectorNotConnectedExternal Alarm Collector is not connected. The detection of external Alarms is not possible. Only valid if powermodule PM:ONU:2G:E is used.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.4.14
shePhysCardEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5
shePhysCardControlResultNotification sent end of a long running card command.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.1
shePhysCardAdminStateChangedThe cards adminState changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.2
shePhysCardStateChangedThe cards operational/availabilty state changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.3
shePhysCardResetCard is performing a reset.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.4
shePhysCardResetEndEnd of card reset.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.5
shePhysCardCreatedCard created.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.6
shePhysCardDeletedCard deleted.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.7
shePhysCardDeletionStartedThe card deletion procedure in the NE was started.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.8
shePhysContainerCardTypeConvertedCard type converted.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.9
shePhysCardConvertionStartedThe card convertion procedure in the NE was started.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.10
shePhysCardPluggedA card was plugged. This notification contains a list of two entPhysicalIndices. First is the entPhysicalIndex of the slot, were these module was plugged and the second, the entPhysicalIndex of the card itself.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.11
shePhysCardUnpluggedA card was unplugged. This notification contains a list of two entPhysicalIndices. First is the entPhysicalIndex of the slot, were these module was plugged before and the second, the entPhysicalIndex of the card itself.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.12
shePhysCardChangedTemperatureThresholdThe temperature threshold has been configured. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5.obsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.13
shePhysCardTemperatureWarningThresholdsChangedConfiguration event.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.5.14
shePhysCardAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.6
shePhysCardTypeMismatchWrong card is plugged.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.1
shePhysCardFailureCard out of service.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.2
shePhysCardProblemCard partly out of service.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.3
shePhysCardNotInstalledCard not plugged.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.4
shePhysCardTemperaturePowerDownTemperature alarm. The IU has detect high temperature and start's first action to reduce power consumption.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.5
shePhysCardOverTemperatureResetCXU has forced IU-Card to reset because of over temperature.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.6
shePhysCardOverTemperatureThresholdCard temperature Threshold alarm. THIS ELEMENT WILL NOT LONGER BE SUPPORTED BY NE up R2.5.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.7
shePhysCardTemperatureWarningTemperature warning alarm. The CXU has detected a higher temperature then the configured value.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.8
shePhysCardSWVersionProblemCard out of service due to wrong SW version. Please upgrade!
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.6.9
shePhysPortEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.7
shePhysPortAdminStateChangedThe ports adminState changed. Could be send as a collection trap. That means, this notification could contain more then one indexed ifAdminState. During system startup normaly a large number of notifications are needed. In such a case, it is possible to send only one notification per card which contain the ifAdminStates of all port's.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.7.1
shePhysPortOperStateChangedThe ports operational state changed. Could be send as a collection trap. That means, this notification could contain more then one indexed ifOperState. During system startup normaly a large number of notifications are needed. In such a case, it is possible to send only one notification per card which contain the ifOperStates of all port's.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.7.2
shePhysPortControlResultNotification of port command ending and result.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.7.3
shePhysPortCreatedNotification about port creation. Could be send as a collection trap. That means, this notification could contain more then one ifIndex. In case of a card creation sequence, normaly a large number of PortCreated-notifications are needed. In such a case, it is possible to send only one notification which contain the ifIndeces of all created port's for the entPhysicalIndex of this new card.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.7.4
shePhysPortDeletedNotification about the succesfull delete of a port. Could be send as a collection trap. That means, this notification could contain more then one ifIndex. In case of a card deletion sequence, normaly a large number of PortDeleted-notifications are needed. In such a case, it is possible to send only one notification which contain the ifIndeces of all deleted port's for the entPhysicalIndex of this card.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.7.5
shePhysPortAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.8
shePhysPortOperStateDownThis is a operstate-down alarm trap. This trap could not be send as collection trap (different from OperStateChanged - Event trap)!! This trap could be blocked by setting in alarmseverity-profile.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.8.1
shePhysRedundancyEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.9
shePhysBrdControlResultNotification of board redundancy command ending and result.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.9.1
shePhysRedundancyStateChangedNotification of change of redundancy ralated attributes of a card.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.9.2
shePhysRedundancyFeatureModifiedModification response trap.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.9.3
shePhysRedundancyInterlinkModifiedThe medium type for interlink has been changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.9.4
shePhysRedundancyAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.10
shePhysRedundancyNoRedundancyRedundancy is not available for a card.
NOTIFICATION-TYPE
.1.3.6.1.4.1.231.7.1.2.2.1.1.5.10.1
shePhysRackObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.6
shePhysRackTableThe shelf/chassis table.
SEQUENCE OF ShePhysRackEntry
.1.3.6.1.4.1.231.7.1.2.2.1.1.6.1
shePhysRackEntryEntry of the rack table. The entries represent the SHE rack.
ShePhysRackEntry
.1.3.6.1.4.1.231.7.1.2.2.1.1.6.1.1
shePhysRackAlarmSeverityIndexA pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1.ro
SheAlarmSevProfileIndex (SHE-ALARMING-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.6.1.1.1
shePhysRackControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.6.2
shePhysRackControlRequestThe rack commands : changeAlarmSeverityProfile: the alarm severity profile of the rack is changed. Notifications : shePhysRackControlResult at the command ending in case of long running command.rw
ShePhysControlRequestType
.1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.1
shePhysRackControlStatusThe status of a user command.ro
SheControlStatusType (SHE-TC-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.2
shePhysRackControlIndexThe entPhysicalIndex of the rack.rw
PhysicalIndex (ENTITY-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.3
shePhysRackControlAlarmSeverityIndexThe new AlarmSeverityIndex of the alarm severity profile assigned to the rack.rw
SheAlarmSevProfileIndex (SHE-ALARMING-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.4
shePhysRackControlTimeStampThe time stamp of the last command (end of command).ro
Unsigned32 UNITS "sec"
.1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.5
shePhysRackControlTimerThe maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysResult .ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.6
shePhysRackControlReqResultThe result of the last user command.ro
ShePhysControlRequestResultType
.1.3.6.1.4.1.231.7.1.2.2.1.1.6.2.7
shePhysShelfObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.7
shePhysShelfTableThe shelf/chassis table.
SEQUENCE OF ShePhysShelfEntry
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1
shePhysShelfEntryEntry of the chassis table. The entries represent the SHE shelf(s).
ShePhysShelfEntry
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1
shePhysShelfAlarmSeverityIndexA pointer to the instance of the alarm severity profile that contains the severity assignments for alarms reported by this managed entity. Default is 1.ro
SheAlarmSevProfileIndex (SHE-ALARMING-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.1
shePhysShelfTypeCodeContains the typecode for the possible used She-Shelf's. Depending on the detected shelftype-code the corresponding system version will be displayed. Systemversion -> Shelftypes SHE hiX5635 -> M1200:E, M1100:E, G1100:E, G1100:A, G1100:B:E SHE hiX5630 -> M600:E, G600:E, G600:R:E, M600:DF:E SHE hiX5625 -> M400:E, G400:E, G400:R:A, SHE hiX5622 R1.0 -> MDUS:E (obsolete because release was canceled) SHE hiX5608 -> 'empty' string because no shelf is used, single box system Shelftype's 2 generation - only new 2G powermodules could be used! (>= with R2.8 maintenance) SHE hiX5635 -> G1100:2G:E, M1100:2G:E SHE hiX5630 -> G600:2G:E, G600:R:2G:E, SHE hiX5625 -> G400:2G:E, G400:R:2G:E, SHE hiX5622 -> G200:2G:E, G200S:2G:Ero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.2
shePhysShelfExternalAlarmOutput01StatusStatus of the external alarm output 01.ro
ShePhysShelfExternalAlarmOutputStatusType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.3
shePhysShelfExternalAlarmOutput01UsageDescription for usage of this external alarm output. Only for managment interface and no special meaning for the NE.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.4
shePhysShelfExternalAlarmOutput02StatusStatus of the external alarm output 02.ro
ShePhysShelfExternalAlarmOutputStatusType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.5
shePhysShelfExternalAlarmOutput02UsageDescription for usage of this external alarm output. Only for managment interface and no special meaning for the NE.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.6
shePhysShelfExternalAlarmOutput03StatusStatus of the external alarm output 03.ro
ShePhysShelfExternalAlarmOutputStatusType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.7
shePhysShelfExternalAlarmOutput03UsageDescription for usage of this external alarm output. Only for managment interface and no special meaning for the NE.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.8
shePhysShelfExternalAlarm01LevelConfigured level for active alarm.ro
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.9
shePhysShelfExternalAlarm01UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hiX5622 R1.0 system (shelftyp MDUS:E): AC Failure -> Powering Alarm - Loss of external power Default usage in hiX5608 R1.0 system: Door Contact -> Physical Intrusion alarm.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.10
shePhysShelfExternalAlarm02LevelConfigured level for active alarm.ro
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.11
shePhysShelfExternalAlarm02UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): DC Failure (internal fault) -> Equipment Alarm - A functional failure on an internal interface.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.12
shePhysShelfExternalAlarm03LevelConfigured level for active alarm.ro
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.13
shePhysShelfExternalAlarm03UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Deep battery discharge -> Battery Low - battery is provisioned and present but voltage is too low.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.14
shePhysShelfExternalAlarm04LevelConfigured level for active alarm.ro
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.15
shePhysShelfExternalAlarm04UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery missing -> Battery is provisioned but missing.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.16
shePhysShelfExternalAlarm05LevelConfigured level for active alarm.ro
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.17
shePhysShelfExternalAlarm05UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Battery replace (end of life) -> Battery Failure - Battery is provisioned and present but cannot recharge.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.18
shePhysShelfExternalAlarm06LevelConfigured level for active alarm.ro
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.19
shePhysShelfExternalAlarm06UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE. Default usage in hix5622 R1.0 system (shelftyp MDUS:E): Door Contact -> Physical Intrusion alarm.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.20
shePhysShelfExternalAlarm07LevelConfigured level for active alarm.ro
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.21
shePhysShelfExternalAlarm07UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.22
shePhysShelfExternalAlarm08LevelConfigured level for active alarm.ro
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.23
shePhysShelfExternalAlarm08UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE.ro
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.24
shePhysShelfRelativeHumidityEnvironmentale parameter for relative humidity in %. This parameter is only valid for shelftype G400R//G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available. In all other cases the value 255 will report, that a valid measurement result is not available.ro
Unsigned32 (0..100 | 255) UNITS "%"
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.25
shePhysShelfRelativeHumidityAlarmOnEnvironmentale parameter for relative humidity alarm threshold on. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available.ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.26
shePhysShelfRelativeHumidityAlarmOffEnvironmentale parameter for relative humidity alarm threshold off. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available.ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.27
shePhysShelfBatteryBackupOptionIndication wether the SHE supports battery backup. Only shelftype SHE hiX5622 R1.0 -> MDUS:E will support battery backup, otherwise false.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.28
shePhysShelfBatteryBackupModeIndication wether battery backup is provisioned. Only valid for shelftype SHE hiX5622 R1.0 -> MDUS:E.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.1.1.29
shePhysShelfControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2
shePhysShelfControlRequestThe chassis commands : changeAlarmSeverityProfile: the alarm severity profile of the chassis is changed. changeShelfExternalAlarmSettings change level for active external alarms and set a descriptional name for usage Notifications : shePhysShelfControlExternalAlarmsConfigurationChanged shePhysShelfControlResult at the command ending in case of long running command. changeShelfRelativeHumidityAlarmThreshold change the alarm threshold configuration for environmental parameter relative humidity Notifications: shePhysShelfControlRelativeHumidityAlarmThresholdChanged hiX5622 R1.0 only: changeShelfBatteryBackupMode: shePhysShelfControlBatteryBackupMode Notifications: shePhysShelfBatteryBackupModified New with R2.8: changeShelfExternalAlarmOutputStatus change status external alarm outputs Notifications : shePhysShelfControlExternalAlarmsOutputStatusChangedrw
ShePhysControlRequestType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.1
shePhysShelfControlStatusThe status of a user command.ro
SheControlStatusType (SHE-TC-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.2
shePhysShelfControlIndexThe entPhysicalIndex of the shelf.rw
PhysicalIndex (ENTITY-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.3
shePhysShelfControlTimeStampThe time stamp of the last command (end of command).ro
Unsigned32 UNITS "sec"
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.4
shePhysShelfControlTimerThe maximum wait time for the manager for command ending in case of long running user commands. The manager reads this value from the PPE SHE. The end of request indicates the trap ShePhysRiResult .ro
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.5
shePhysShelfControlReqResultThe result of the last user command.ro
ShePhysControlRequestResultType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.6
shePhysShelfControlAlarmSeverityIndexThe new AlarmSeverityIndex of the alarm severity profile assigned to the chassis.rw
SheAlarmSevProfileIndex (SHE-ALARMING-MIB)
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.7
shePhysShelfControlExternalAlarmOutput01UsageDescription for usage of this external alarm output. Only for managment interface and no special meaning for the NE.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.8
shePhysShelfControlExternalAlarmOutput02UsageDescription for usage of this external alarm output. Only for managment interface and no special meaning for the NE.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.9
shePhysShelfControlExternalAlarmOutput03UsageDescription for usage of this external alarm output. Only for managment interface and no special meaning for the NE.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.10
shePhysShelfControlExternalAlarm01LevelConfigured level for active alarm.rw
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.11
shePhysShelfControlExternalAlarm01UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.12
shePhysShelfControlExternalAlarm02LevelConfigured level for active alarm.rw
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.13
shePhysShelfControlExternalAlarm02UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.14
shePhysShelfControlExternalAlarm03LevelConfigured level for active alarm.rw
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.15
shePhysShelfControlExternalAlarm03UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.16
shePhysShelfControlExternalAlarm04LevelConfigured level for active alarm.rw
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.17
shePhysShelfControlExternalAlarm04UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.18
shePhysShelfControlExternalAlarm05LevelConfigured level for active alarm.rw
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.19
shePhysShelfControlExternalAlarm05UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.20
shePhysShelfControlExternalAlarm06LevelConfigured level for active alarm.rw
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.21
shePhysShelfControlExternalAlarm06UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.22
shePhysShelfControlExternalAlarm07LevelConfigured level for active alarm.rw
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.23
shePhysShelfControlExternalAlarm07UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.24
shePhysShelfControlExternalAlarm08LevelConfigured level for active alarm.rw
ShePhysShelfExternalAlarmLevelType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.25
shePhysShelfControlExternalAlarm08UsageDescription for usage of this external alarm. Only for managment interface and no special meaning for the NE.rw
OCTET STRING
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.26
shePhysShelfControlRelativeHumidityAlarmOnConfigure the environmentale parameter for relative humidity alarm threshold on. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available.rw
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.27
shePhysShelfControlRelativeHumidityAlarmOffConfigure the environmentale parameter for relative humidity alarm threshold off. This parameter is only valid for shelftype G400R/G600:R:E with powermodule PM_R is plugged and optional humidity sensor is available.rw
Unsigned32
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.28
shePhysShelfControlBatteryBackupModeProvisioning of battery backup. Only valid for shelftype SHE hiX5622 R1.0 -> MDUS:E.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.29
shePhysShelfControlExternalAlarmOutput01StatusSet the status of the external alarm output 01.rw
ShePhysShelfExternalAlarmOutputStatusType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.30
shePhysShelfControlExternalAlarmOutput02StatusSet the status of the external alarm output 02.rw
ShePhysShelfExternalAlarmOutputStatusType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.31
shePhysShelfControlExternalAlarmOutput03StatusSet the status of the external alarm output 03.rw
ShePhysShelfExternalAlarmOutputStatusType
.1.3.6.1.4.1.231.7.1.2.2.1.1.7.2.32
shePhysicalConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.100
shePhysicalGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.100.1
shePhysicalGroupDescription.
Unknown
.1.3.6.1.4.1.231.7.1.2.2.1.1.100.1.1
shePhysicalControlGroupDescription.
Unknown
.1.3.6.1.4.1.231.7.1.2.2.1.1.100.1.2
shePhysicalNotificationGroupThis group supports notifications of significant conditions associated with physical objects.
Unknown
.1.3.6.1.4.1.231.7.1.2.2.1.1.100.1.3
shePhysicalObsoleteGroupDescription.obsolete
Unknown
.1.3.6.1.4.1.231.7.1.2.2.1.1.100.1.4
shePhysicalObsoleteNotificationGroupDescription.obsolete
Unknown
.1.3.6.1.4.1.231.7.1.2.2.1.1.100.1.5
shePhysicalCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.231.7.1.2.2.1.1.100.2
shePhysicalMibComplianceThe compliance statement for SNMP entities which manage physical interfaces in SHE.
Unknown
.1.3.6.1.4.1.231.7.1.2.2.1.1.100.2.1
SHE-PHYSICAL-MIB - SNMP MIB Reference | MIBs Explorer