SERVERVIEW-STATUS-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for SERVERVIEW-STATUS-MIB.
64
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
64 total| Object Name |
|---|
sni OBJECT IDENTIFIER .1.3.6.1.4.1.231 |
IMPORTS Unknown .1.3.6.1.4.1.231 |
sniProductMibs OBJECT IDENTIFIER .1.3.6.1.4.1.231.2 |
sniExtensions OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10 |
sniServerMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2 |
sieStTrapStatusChangedSystem status has changed. TRAP-TYPE .1.3.6.1.4.1.231.2.10.2.0.1100 |
sniInventory OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.1 |
sniCommon OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.2 |
sniBios OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.2.1 |
sniEisa OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.2.2 |
sniHd OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.2.3 |
sniBus OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.2.4 |
sniServerControl OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.2.5 |
sniPcSpecific OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.3 |
sniScb OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.4 |
sniOsSpecific OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.5 |
sniNetware OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.5.1 |
sniWinNt OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.5.2 |
sniOs2 OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.5.3 |
sniUnix OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.5.4 |
sniOemComponents OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.6 |
sniOemDpt OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.6.1 |
sniOemMylex OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.6.2 |
sniMlxDiskArray OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.6.2.1 |
sniSecurity OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.7 |
sniSmSecurity OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.7.1 |
sniServerView OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.8 |
sieStatusAgent OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.11 |
sieStAgentInfo OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.11.1 |
sieStAgentIdAgent identification stringro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.1.1 |
sieStAgentCompanyAgent company namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.1.2 |
sieStAgentVersionStringAgent version string <Major>.<Minor> (i.e. 1.05)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.1.3 |
sieStAgentBuildBuild time and date of agent program implementationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.1.4 |
sieStSystemStatus OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.11.2 |
sieStSystemStatusValueOverall status of this system:
ok(1): all subsystems and components working properly, no failure
degraded(2): redundant components failed or signal a warning
error(3): severe problem, system may no longer work properly
failed(4): this value is obsolete - will no longer appear
unknown(5): none of the subsystems had a valid status (e.g. during initialization)ro Enumeration .1.3.6.1.4.1.231.2.10.2.11.2.1 |
sieStSystemLastErrorMessageError message text of the component that has failed last. Empty string,
if no error has happened since reboot. This object is not supported by
all components and can therefore be empty although an error happened.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.2.2 |
sieStSubsystemListList if subsystems included in this system, separated
by blank spaces. E.g. 'Environment PowerSupply MassStorage'ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.2.3 |
sieStSystemIdentifySets the signal IDENTIFY for the system:
off(1): clear the identify signal / signal is off
on(2): set the IDENTIFY signal
not-available(3): identify signal ist not available (this value cannot be set)
blinking(4): IDENTIFY LED blinking, used for different purposes
Setting IDENTIFY by the ServerView application normally sets a LED
to have the possibility to identify a system selected by ServerView.rw Enumeration .1.3.6.1.4.1.231.2.10.2.11.2.4 |
sieStSubsystemStatus OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.11.3 |
sieStSubsystemTableTable containing the monitored subsystems SEQUENCE OF SieStSubsystems .1.3.6.1.4.1.231.2.10.2.11.3.1 |
sieStSubsystems SieStSubsystems .1.3.6.1.4.1.231.2.10.2.11.3.1.1 |
sieStSubsystemNumberSubsystem number (index, 1..n)ro INTEGER .1.3.6.1.4.1.231.2.10.2.11.3.1.1.1 |
sieStSubsystemNameSubsystem name. This name identifies the subsystem and will never
be changed if once defined. This name is a string like 'Environment',
'PowerSupply', 'MassStorage' etc.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.3.1.1.2 |
sieStSubsystemStatusValueSubsystem status value:
ok(1): all components in this subsystem working properly
degraded(2): redundant components failed or signal a warning
error(3): severe problem, system may no longer work properly
failed(4): this value is obsolete - will no longer appear
unknown(5): none of the components had a valid status (initialization, no components)ro Enumeration .1.3.6.1.4.1.231.2.10.2.11.3.1.1.3 |
sieStSubsystemLastErrorMessageError message text of the component that has failed last. Empty string,
if no error has happened since reboot. This object is not supported by
all components and can therefore be empty although an error happened.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.3.1.1.4 |
sieStSubsystemComponentsList if components (short names) included in this subsystem, separated
by blank spaces; e.g. 'SvPowerSupply OemUpsAPC'ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.3.1.1.5 |
sieStSubsystemDisplayNameSubsystem display name string.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.3.1.1.6 |
sieStNumberSubsystemsNumber of available subsystems; this is the number of entries in the subsystem tablero INTEGER .1.3.6.1.4.1.231.2.10.2.11.3.2 |
sieStComponentStatus OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.11.4 |
sieStComponentTableTable containing the monitored components SEQUENCE OF SieStComponents .1.3.6.1.4.1.231.2.10.2.11.4.1 |
sieStComponents SieStComponents .1.3.6.1.4.1.231.2.10.2.11.4.1.1 |
sieStComponentNumberComponent number (index, 1..n)ro INTEGER .1.3.6.1.4.1.231.2.10.2.11.4.1.1.1 |
sieStComponentNameComponent name/tag. This name identifies the component and will never
be changed if once defined. This name is a string like 'SvEnvironment',
'SvVoltages', 'OemUpsAPC' etc.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.4.1.1.2 |
sieStComponentStatusValueComponent status value:
ok(1): component is working properly
degraded(2): redundant component has failed or signals a warning
error(3): severe problem, system may no longer work properly
failed(4): this value is obsolete - will no longer appear
unknown(5): component had no valid status (initialization, no instances)
notPresent(6): component is not present (e.g. empty socket)
notManageable(7): component is not manageablero Enumeration .1.3.6.1.4.1.231.2.10.2.11.4.1.1.3 |
sieStComponentLastErrorMessageError message text of the current component. Empty string,
if no error has happened since reboot. This object is not supported by
all components and can therefore be empty although an error happened.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.4.1.1.4 |
sieStComponentDisplayNameComponent display name string.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.4.1.1.5 |
sieStComponentConfirmFailureConfirm a failure status of a component that does not automatically
reset its status (e.g. BIOS selftest error). The error condition is
removed after the failure has been confirmed.
GET values: 0 - no failure to confirm; SET not possible
>0 - component failure; SET a zero value to confirm
SET values: 0 - confirm failure and remove error condition
(setting other values than 0 is not possible)rw INTEGER .1.3.6.1.4.1.231.2.10.2.11.4.1.1.6 |
sieStNumberComponentsNumber of available components; this is the number of entries in the component tablero INTEGER .1.3.6.1.4.1.231.2.10.2.11.4.2 |
sieStAgentParameters OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.11.5 |
sieStAgentTypeType of agent (i.e. 'Desktop' or 'Server').
This field can be used to launch the correct management front end
application (DeskView or ServerView) in enterprise management systems.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.5.1 |
sieStTrapParameters OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.2.11.10 |
sieStTrapParamServerNameName of server the trap occured at DisplayString (SNMPv2-TC) .1.3.6.1.4.1.231.2.10.2.11.10.1 |
sieStTrapParamTimestampTime the trap occured (in seconds since 01/01/1970 00:00h) INTEGER .1.3.6.1.4.1.231.2.10.2.11.10.2 |
sniTrapMib OBJECT IDENTIFIER .1.3.6.1.4.1.231.2.10.5 |