S5-ETH-REDUNDANT-LINKS-MIB
The S5-ETH-REDUNDANT-LINKS-MIB monitors Ethernet link redundancy states and interface status on Nortel Networks 5000 series switches to track failover conditions and active path availability.
Imported Objects
Objects
19 total| Object Name |
|---|
s5EnRedun OBJECT IDENTIFIER .1.3.6.1.4.1.45.1.6.6.1.2 |
IMPORTS Unknown .1.3.6.1.4.1.45.1.6.6.1.2 |
s5EnRedPortTable SEQUENCE OF S5EnRedPortEntry .1.3.6.1.4.1.45.1.6.6.1.2.1 |
s5EnRedPortEntry S5EnRedPortEntry .1.3.6.1.4.1.45.1.6.6.1.2.1.1 |
s5EnRedPortBrdIndxro INTEGER .1.3.6.1.4.1.45.1.6.6.1.2.1.1.1 |
s5EnRedPortPortIndxro INTEGER .1.3.6.1.4.1.45.1.6.6.1.2.1.1.2 |
s5EnRedPortCapabilityro Enumeration .1.3.6.1.4.1.45.1.6.6.1.2.1.1.3 |
s5EnRedPortRedundModerw Enumeration .1.3.6.1.4.1.45.1.6.6.1.2.1.1.4 |
s5EnRedPortOperStatusro Enumeration .1.3.6.1.4.1.45.1.6.6.1.2.1.1.5 |
s5EnRedPortRemoteOperStatusro Enumeration .1.3.6.1.4.1.45.1.6.6.1.2.1.1.6 |
s5EnRedPortRemFltSelectModerw Enumeration .1.3.6.1.4.1.45.1.6.6.1.2.1.1.7 |
s5EnRedPortTxModerw Enumeration .1.3.6.1.4.1.45.1.6.6.1.2.1.1.8 |
s5EnRedPortFaultsro Counter .1.3.6.1.4.1.45.1.6.6.1.2.1.1.9 |
s5EnRedPortModeChangesro Counter .1.3.6.1.4.1.45.1.6.6.1.2.1.1.10 |
s5EnRedPortCompanionBrdNumrw INTEGER .1.3.6.1.4.1.45.1.6.6.1.2.1.1.11 |
s5EnRedPortCompanionPortNumrw INTEGER .1.3.6.1.4.1.45.1.6.6.1.2.1.1.12 |
s5EnRedPortSwitchoverStatusrw Enumeration .1.3.6.1.4.1.45.1.6.6.1.2.1.1.13 |
s5EnRedPortSwitchoverTimerw TimeIntervalSec .1.3.6.1.4.1.45.1.6.6.1.2.1.1.14 |
s5EnRedLastChgro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.45.1.6.6.1.2.2 |
S5-ETH-REDUNDANT-LINKS-MIB Technical Reference Overview
The S5-ETH-REDUNDANT-LINKS-MIB SNMP MIB module published by Synoptics defines 19 managed OID objects, including 16 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events. Key tabular structures include s5EnRedPortTable.
Key OID Definitions in S5-ETH-REDUNDANT-LINKS-MIB
.1.3.6.1.4.1.45.1.6.6.1.2.1A table with redundancy status and control for each redundancy-capable port in the chassis. The number of entries is determined by the number of redundancy-capable ports in the chassis. The ports appearing in this table can be divided into two categories: Those with remote fault signaling capability and those without. The latter kind depends on the port link status to provide the required redundancy. Ports that are not capable of supporting redundancy do not have an entry in this table.
.1.3.6.1.4.1.45.1.6.6.1.2.2The value of sysUpTime when the last change in the redundant ports table was observed by the agent.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1A row in the table of redundancy status and control for each redundancy-capable port in the chassis. Entries in the table cannot be created or deleted via SNMP.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.1The index of the slot containing the board on which the port is located.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.2The index of the port on the board.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.3The redundancy capability of the port: hwRedOnly(1).....hardware redundancy only. swRedOnly(2).....software redundacy only. hwAndSwRed(3)....both hardware and software redundancy. A value of hwRedOnly(1) or hwAndSwRed(3) means that the port is capable of being configured into a hardware-redundant pair. In this case, the identity of the potential redundant companion is given by the objects s5EnRedPortCompanionBrdNum and s5EnRedPortCompanionPortNum. A value of swRedOnly(2) or hwAndSwRed(3) means that the port is capable of being configured into a software-redundant pair.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.4The redundancy mode of the port. The values when written change the redundancy mode, and when read report the redundancy mode: standalone(1)..the port is not in any redundant pair. hwActive(2)....the port is the active companion in a hardware-redundant pair. hwStandby(3)...the port is the standby companion in a hardware-redundant pair. swActive(4)....the port is the active companion in a software-redundant pair. swStandby(5)...the port is the standby companion in a software-redundant pair. The values that can be written, which change the redundancy mode, are: standalone(1)...causes the redundant pair to be broken up. hwActive(2).....if the previous value was hwStandby(3), this value will cause the port to become the active port in the hardware-redundant pair, resulting in a switchover. hwStandby(3)....if the previous value was hwActive(2), this value will cause the port to become the standby port in the hardware-redundant pair, resulting in a switchover. swActive(4).....if the previous value was swStandby(5), this value will cause the port to become the active port in the software-redundant pair, resulting in a switchover. swStandby(5)....if the previous value was swActive(4), this value will cause the port to become the standby port in the software-redundant pair, resulting in a switchover. To create a hardware-redundant pair, change this object to hwActive(2) or hwStandby(3). To create a software-redundant pair, change this object to swActive(4) or swStandby(5). The same SNMP SET PDU must also write to objects s5EnRedPortCompanionBrdNum and s5EnRedPortCompanionPortNum.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.5The redundancy status of the port. The values are: other(1).............none of the following. ok(2)...................no fault localFault(3)....the local port has sensed a fault condition. remoteFault(4)...the remote port has sensed a fault condition and has signaled the local port accordingly. Either a localFault(3) or remoteFault(4) condition should cause a healthy redundant port pair to switchover. If the port does not belong to a redundant pair, a value of other(1) is returned. Note: If the redundant link consists of ports without remote fault capability, the value remoteFault(4) will not be reported and the value localFault(3) implies that link is off.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.6This object reflects the real time status of the received data from the remote port. The values are: snpxFLRemFltCpblPortUp(1)....10BASE-FL signaling, plus capable of SynOptics proprietary remote fault signaling. A remote fault on such a port is indicated by snpxRemFltCpblPortFault(5). snpxFLFBRemFltCpblPortUp(2)..10BASE-FL signaling, plus capable of SynOptics proprietary remote fault signaling and 10BASE-FB signaling. A remote fault on such a port is indicated by snpxRemFltCpblPortFault(5). tenBaseTFLPortUp(3)...........regular idle 10BASE-T or 10BASE-FL signaling, and is incapable of remote fault signaling. tenBaseFBPortUp(4)...........10BASE-FB synchronous signaling. A remote fault on such a port is indicated by tenBaseFBPortFault(6). snpxRemFltCpblPortFault(5)...SynOptics proprietary remote fault signaling. tenBaseFBPortFault(6)........10BASE-FB remote fault signaling. unknown(7)...................none of the above. A value of snpxFLRemFltCpblPortUp(1) indicates that the remote port is using 10BASE-FL signaling, and is capable of SynOptics proprietary idle and remote fault signaling. A remote fault on such a port is indicated by snpxRemFltCpblPortFault(5). A value of snpxFLFBRemFltCpblPortUp(2) indicates that the remote port is using 10BASE-FL signaling, and is capable of SynOptics proprietary idle and remote fault signaling, and is also capable of synchronous signaling. A remote fault on such a port is indicated by snpxRemFltCpblPortFault(5). A value of tenBaseFLPortUp(3) indicates that the remote port uses regular idle 10BASE-FL signaling, and is incapable of remote fault signaling. A value of tenBaseFBPortUp(4) indicates that the remote port uses 10BASE-FB synchronous signaling. A remote fault on such a port is indicated by tenBaseFBPortFault(6).
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.7This mode specifies the set of local fault events which will cause a switchover. The values are: synoptics(1)..The SynOptics Tx Remote Fault events consist of auto-partition and NM (network management) partition events in addition to the standard events. standard(2)...The standard events are link-off for all ports, and low light, jabber, Rx invalid idle, Tx dark, and Tx remote fault (for diagnostics) for ports with transmit remote fault capability.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.8The Transmit Fiber Mode, which determines the port transmit idle. The values are: autoCfg(1)...The port will auto configure based upon the received idle. fl(2)........The port is configured in FL mode. fb(3)........The port is configured in FB mode. other(4).....None of the above. The port is not a fiber port. The value other(4) is read-only.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.9A count of local or remote faults on this port. This counter increments on a transition between the fault and no-fault states.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.10A count of the number of times this port has transitioned from standby mode to non-standby mode (includes active mode and standalone mode), or vice versa.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.11The index of the slot containing the board of the other port in the redundant pair. If the port (whose slot-port identity is given by the instance) is hardware-redundant capable, this object has the value of the slot number of the (potential) redundant companion, even if the port is in standalone mode. This allows the network manager to determine the identity of the potential companion, which is fixed by the hardware of the board. Changing this object is permitted only when creating a software-redundant pair.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.12The index of the other port in the redundant pair. If the port (whose slot-port identity is given by the instance) is hardware-redundant capable, this object has the value of the port number of the (potential) redundant companion, even if the port is in standalone mode. This allows the network manager to determine the identity of the potential companion, which is fixed by the hardware of the board. Changing this object is permitted only when creating a software-redundant pair.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.13The switchover status of the port (and its companion). The following values can be written: timedSwitchover(2)...cause a timed switchover (see value of s5EnRedPortSwitchoverTime) The following values reflect the switchover status of the redundant port pair: other(1)..............not undergoing switchover timedSwitchover(2)....port is undergoing timed switchover (see value of s5EnRedPortSwitchoverTime). On GETs with switchover status of timedSwitchover(2), if the time remaining before the completion of the switchover and reversal is available, it will be reported in object s5EnRedPortSwitchoverTime as a positive value If not available, the value of s5EnRedSwitchoverTime will be zero. When changing a port to timedSwitchover(2), the SET request must also contain the value for object s5EnRedSwitchoverTime.
.1.3.6.1.4.1.45.1.6.6.1.2.1.1.14The length of time between switching over a redundant port pair and switching back, when a timed switchover is done to the port. This object can only be written in the same request that sets s5EnRedPortSwitchoverStatus to timedSwitchover(2). Afterwards, it indicates the amount of time left before the timed switchover is completed, at which time another switchover occurs and s5EnRedSwitchoverStatus is changed to other(1). This object has the value of zero if the port is not undergoing a timed switchover, or if the amount of time is not available.
More MIBs from Synoptics
Browse all SynopticsMIBs →Standard SNMP MIB module defining data structures for SYNOPTICS-BASIC-ETHTOK-MIB.
Standard SNMP MIB module defining data structures for SYNOPTICS-ETHERNET-MIB.
The NTWS-AP-STATUS-MIB enables SNMP-based monitoring of Access Point operational states and connectivity metrics on Nortel Networks wireless switches (Access Controllers). It provides specific management objects for tracking the status, association, and performance indicators of wireless Access Points managed by the switch's agent.
The NTWS-AP-CONFIG-MIB enables SNMP-based configuration management of Access Point parameters on Nortel Networks wireless switches (Access Controllers), specifically exposing objects for SSID settings, radio channel assignments, transmit power levels, and security policy definitions. This module allows centralized controllers to retrieve and modify the operational state of associated lightweight access points without requiring direct agent interaction on the AP hardware.
The NTWS-TRAP-MIB module defines SNMP notification objects for Nortel Networks wireless switches (Access Controllers) to report critical operational events and fault conditions for associated Access Points. These notifications enable network management systems to detect and respond to specific wireless infrastructure anomalies, such as AP connectivity loss, controller failures, or configuration state changes.
The S5-CHASSIS-MIB provides SNMP-based management and monitoring of physical chassis components, including power supplies, fans, and temperature sensors, specifically for Nortel Networks 5000 series switching hardware. It enables the retrieval of hardware status, fault detection, and environmental telemetry required for maintaining the operational integrity of these legacy network platforms.