S5-CHASSIS-TRAP-MIB
The S5-CHASSIS-TRAP-MIB defines SNMP trap definitions for Nortel Networks 5000 series chassis devices to report critical hardware status events and fault conditions. It enables network management systems to receive asynchronous notifications regarding chassis-level anomalies, such as power supply failures, fan module faults, or card insertion/removal events.
Imported Objects
Objects
12 total| Object Name |
|---|
s5ChassisTrapMib MODULE-IDENTITY .1.3.6.1.4.1.45.1.6.2.4.0 |
s5CtrNewHotSwap NOTIFICATION-TYPE .1.3.6.1.4.1.45.1.6.2.4.0.1 |
s5CtrNewProblem NOTIFICATION-TYPE .1.3.6.1.4.1.45.1.6.2.4.0.2 |
s5CtrNewUnitUp NOTIFICATION-TYPE .1.3.6.1.4.1.45.1.6.2.4.0.3 |
s5CtrNewUnitDown NOTIFICATION-TYPE .1.3.6.1.4.1.45.1.6.2.4.0.4 |
s5CtrFanRotationError NOTIFICATION-TYPE .1.3.6.1.4.1.45.1.6.2.4.0.5 |
s5CtrFanDirectionError NOTIFICATION-TYPE .1.3.6.1.4.1.45.1.6.2.4.0.6 |
s5CtrHighTemperatureError NOTIFICATION-TYPE .1.3.6.1.4.1.45.1.6.2.4.0.7 |
s5CtrHotSwap NOTIFICATION-TYPE .1.3.6.1.4.1.45.1.6.2.4.1 |
s5CtrProblem NOTIFICATION-TYPE .1.3.6.1.4.1.45.1.6.2.4.2 |
s5CtrUnitUp NOTIFICATION-TYPE .1.3.6.1.4.1.45.1.6.2.4.3 |
s5CtrUnitDown NOTIFICATION-TYPE .1.3.6.1.4.1.45.1.6.2.4.4 |
S5-CHASSIS-TRAP-MIB Technical Reference Overview
The S5-CHASSIS-TRAP-MIB SNMP MIB module published by Synoptics defines 12 managed OID objects, including 0 scalar/column metrics, 0 SNMP tables, and 11 trap/notification events anchored at base OID .1.3.6.1.4.1.45.1.6.2.4.0. Monitored SNMP traps/notifications include s5CtrHotSwap, s5CtrProblem, s5CtrUnitUp, s5CtrUnitDown, s5CtrNewHotSwap, s5CtrNewProblem.
Key OID Definitions in S5-CHASSIS-TRAP-MIB
.1.3.6.1.4.1.45.1.6.2.4.05000 Chassis Trap MIB Copyright 1993-2004 Nortel Networks, Inc. All rights reserved. This Nortel Networks SNMP Management Information Base Specification (Specification) embodies Nortel Networks' confidential and proprietary intellectual property. Nortel Networks retains all title and ownership in the Specification, including any revisions. This Specification is supplied 'AS IS,' and Nortel Networks makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
.1.3.6.1.4.1.45.1.6.2.4.1A component or sub-component was inserted or deinserted in the chassis. This trap is sent only once when the condition is first detected. The following values are returned: s5ChasComType........the type of the component (or sub-component) that was inserted or deinserted, with the instance identifying the group, component, and sub-component. s5ChasComOperState...the operational status of the component or sub-component, with the instance identifying the group, component, and sub-component. The value is removed(3) when the item is removed.
.1.3.6.1.4.1.45.1.6.2.4.2A component or sub-component has a problem condition, either warning, nonfatal, or fatal. This trap is sent only once when the condition is first detected. The following values are returned: s5ChasComType........the type of the component (or sub-component) that has the problem condition, with the instance identifying the group, component, and sub-component. s5ChasComOperState...the operational status of the component or sub-component, with the instance identifying the group, component, and sub-component.
.1.3.6.1.4.1.45.1.6.2.4.3A component or sub-component has been newly detected. This trap is sent only once when the condition is first detected. The following values are returned: s5ChasComType........the type of the component (or sub-component) that has the problem condition, with the instance identifying the group, component, and sub-component. s5ChasComOperState...the operational status of the component or sub-component, with the instance identifying the group, component, and sub-component.
.1.3.6.1.4.1.45.1.6.2.4.4A component or sub-component is no longer detected. This trap is sent only once when the condition is first detected. The following values are returned: s5ChasComType........the type of the component (or sub-component) that has the problem condition, with the instance identifying the group, component, and sub-component. s5ChasComOperState...the operational status of the component or sub-component, with the instance identifying the group, component, and sub-component.
.1.3.6.1.4.1.45.1.6.2.4.0.1A component or sub-component was inserted or deinserted in the chassis. This trap is sent only once when the condition is first detected. The following values are returned: s5ChasComType........the type of the component (or sub-component) that was inserted or deinserted, with the instance identifying the group, component, and sub-component. s5ChasComOperState...the operational status of the component or sub-component, with the instance identifying the group, component, and sub-component. The value is removed(3) when the item is removed.
.1.3.6.1.4.1.45.1.6.2.4.0.2A component or sub-component has a problem condition, either warning, nonfatal, or fatal. This trap is sent only once when the condition is first detected. The following values are returned: s5ChasComType........the type of the component (or sub-component) that has the problem condition, with the instance identifying the group, component, and sub-component. s5ChasComOperState...the operational status of the component or sub-component, with the instance identifying the group, component, and sub-component.
.1.3.6.1.4.1.45.1.6.2.4.0.3A component or sub-component has been newly detected. This trap is sent only once when the condition is first detected. The following values are returned: s5ChasComType........the type of the component (or sub-component) that has the problem condition, with the instance identifying the group, component, and sub-component. s5ChasComOperState...the operational status of the component or sub-component, with the instance identifying the group, component, and sub-component.
.1.3.6.1.4.1.45.1.6.2.4.0.4A component or sub-component is no longer detected. This trap is sent only once when the condition is first detected. The following values are returned: s5ChasComType........the type of the component (or sub-component) that has the problem condition, with the instance identifying the group, component, and sub-component. s5ChasComOperState...the operational status of the component or sub-component, with the instance identifying the group, component, and sub-component.
.1.3.6.1.4.1.45.1.6.2.4.0.5A fan component's rotation is incorrect.
.1.3.6.1.4.1.45.1.6.2.4.0.6A fan component's direction is incorrect.
.1.3.6.1.4.1.45.1.6.2.4.0.7The system is overheated.
More MIBs from Synoptics
Browse all SynopticsMIBs →Standard SNMP MIB module defining data structures for SYNOPTICS-BASIC-ETHTOK-MIB.
Standard SNMP MIB module defining data structures for SYNOPTICS-ETHERNET-MIB.
The NTWS-AP-STATUS-MIB enables SNMP-based monitoring of Access Point operational states and connectivity metrics on Nortel Networks wireless switches (Access Controllers). It provides specific management objects for tracking the status, association, and performance indicators of wireless Access Points managed by the switch's agent.
The NTWS-AP-CONFIG-MIB enables SNMP-based configuration management of Access Point parameters on Nortel Networks wireless switches (Access Controllers), specifically exposing objects for SSID settings, radio channel assignments, transmit power levels, and security policy definitions. This module allows centralized controllers to retrieve and modify the operational state of associated lightweight access points without requiring direct agent interaction on the AP hardware.
The NTWS-TRAP-MIB module defines SNMP notification objects for Nortel Networks wireless switches (Access Controllers) to report critical operational events and fault conditions for associated Access Points. These notifications enable network management systems to detect and respond to specific wireless infrastructure anomalies, such as AP connectivity loss, controller failures, or configuration state changes.
The S5-CHASSIS-MIB provides SNMP-based management and monitoring of physical chassis components, including power supplies, fans, and temperature sensors, specifically for Nortel Networks 5000 series switching hardware. It enables the retrieval of hardware status, fault detection, and environmental telemetry required for maintaining the operational integrity of these legacy network platforms.