Home/Catalog/S410-MIB

S410-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

289
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

289 total
Object Name
asentria
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052
RFC1155-SMI
Unknown
.1.3.6.1.4.1.3052
s410
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40
contact1ActiveTrapSent to show Contact 1 is in the alarm state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20001
contact2ActiveTrapSent to show Contact 2 is in the alarm state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20002
contact3ActiveTrapSent to show Contact 3 is in the alarm state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20003
contact4ActiveTrapSent to show Contact 4 is in the alarm state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20004
contact5ActiveTrapSent to show Contact 5 is in the alarm state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20005
contact6ActiveTrapSent to show Contact 6 is in the alarm state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20006
contact7ActiveTrapSent to show Contact 7 is in the alarm state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20007
contact8ActiveTrapSent to show Contact 8 is in the alarm state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20008
contact9ActiveTrapSend to show Contact 9 is in the alarm state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20009
tempHighTrapSent to show Temp exceeded High Temp Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20010
tempVeryHighTrapSent to show Temp exceeded Very High Temp Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20011
tempLowTrapSent to show Temp went below Low Temp Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20012
tempVeryLowTrapSent to show Temp went below Very Low Temp Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20013
humidityHighTrapSent to show humidity exceeded High humidity Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20020
humidityVeryHighTrapSent to show humidity exceeded Very High humidity Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20021
humidityLowTrapSent to show humidity went below Low humidity Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20022
humidityVeryLowTrapSent to show humidity went below Very Low humidity Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20023
analog1HighTrapSent to show analog1 exceeded High analog1 Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20030
analog1VeryHighTrapSent to show analog1 exceeded Very High analog1 Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20031
analog1LowTrapSent to show analog1 went below Low analog1 Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20032
analog1VeryLowTrapSent to show analog1 went below Very Low analog1 Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20033
analog2HighTrapSent to show analog2 exceeded High analog2 Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20040
analog2VeryHighTrapSent to show analog2 exceeded Very High analog2 Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20041
analog2LowTrapSent to show analog2 went below Low analog2 Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20042
analog2VeryLowTrapSent to show analog2 went below Very Low analog2 Threshold
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20043
contactESActiveTrapSent to show EventSensor contact is in the alarm state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20101
tempESHighTrapSent to show Temp exceeded High Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20110
tempESVeryHighTrapSent to show Temp exceeded Very High Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20111
tempESLowTrapSent to show Temp went below Low Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20112
tempESVeryLowTrapSent to show Temp went below Very Low Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20113
humidityESHighTrapSent to show humidity exceeded High Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20120
humidityESVeryHighTrapSent to show humidity exceeded Very High Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20121
humidityESLowTrapSent to show humidity went below Low Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20122
humidityESVeryLowTrapSent to show humidity went below Very Low Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20123
voltageESHighTrapSent to show voltage exceeded High Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20130
voltageESVeryHighTrapSent to show voltage exceeded Very High Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20131
voltageESLowTrapSent to show voltage went below Low Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20132
voltageESVeryLowTrapSent to show voltage went below Very Low Threshold on an EventSensor
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.20133
contact1NormalTrapSent to show Contact 1 is in the normal state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21001
contact2NormalTrapSent to show Contact 2 is in the normal state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21002
contact3NormalTrapSent to show Contact 3 is in the normal state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21003
contact4NormalTrapSent to show Contact 4 is in the normal state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21004
contact5NormalTrapSent to show Contact 5 is in the normal state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21005
contact6NormalTrapSent to show Contact 6 is in the normal state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21006
contact7NormalTrapSent to show Contact 7 is in the normal state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21007
contact8NormalTrapSent to show Contact 8 is in the normal state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21008
contact9NormalTrapSend to show Contact 9 is in the normal state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21009
tempNormalTrapSent to show Temp went back to Normal range
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21010
humidityNormalTrapSent to show Humidity went back to Normal range
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21020
analog1NormalTrapSent to show analog1 went back to Normal range
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21030
analog2NormalTrapSent to show analog2 went back to Normal range
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21040
contactESNormalTrapSend to show EventSensor contact has returned to normal state
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21101
tempESNormalTrapSent to show EventSensor Temp went back to Normal range
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21110
humidityESNormalTrapSent to show EventSensor Humidity went back to Normal range
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21120
voltageESNormalTrapSent to show EventSensor voltage went back to Normal range
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.21130
testTrapSent for testing the SNMP interface
TRAP-TYPE
.1.3.6.1.4.1.3052.40.0.22000
device
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.1
serialNumber8-character serial numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.1.1
firmwareVersionFirmware version text stringro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.1.2
siteIDSite Identifier, up to 12 characters.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.1.3
snmpManagerThis is snmp manager #1rwdeprecated
IpAddress
.1.3.6.1.4.1.3052.40.1.4
input78ModeMode of operation of inputs 7/8. 0-analog 1&2 =default, 1-contacts 7&8rodeprecated
INTEGER
.1.3.6.1.4.1.3052.40.1.5
forceTrapsAny write non-zero forces set of traps to be send to the SNMP Managerrw
INTEGER
.1.3.6.1.4.1.3052.40.1.6
thisTrapTextA text string included in all trapsrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.1.7
alarmStatusA text status of all alarmsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.1.8
snmpManager1SNMP manager #1rw
IpAddress
.1.3.6.1.4.1.3052.40.1.9
snmpManager2SNMP manager #2rw
IpAddress
.1.3.6.1.4.1.3052.40.1.10
snmpManager3SNMP manager #3rw
IpAddress
.1.3.6.1.4.1.3052.40.1.11
snmpManager4SNMP manager #4rw
IpAddress
.1.3.6.1.4.1.3052.40.1.12
statusRepeatHours0=none, 1-24 Number of Hours between Status Traps being Sentrw
INTEGER
.1.3.6.1.4.1.3052.40.1.13
serialTimeout5-30, Minutes of non-activity timeout on serial setuprw
INTEGER
.1.3.6.1.4.1.3052.40.1.14
powerupTrapsend0-no, 1-yes, send traps for all sensors on poweruprw
INTEGER
.1.3.6.1.4.1.3052.40.1.15
netlossTrapsend0-no, 1-yes, send traps for detected netloss and back uprw
INTEGER
.1.3.6.1.4.1.3052.40.1.16
buildID5-chars max text for build identifierro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.1.17
contacts
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.2
contact1
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.2.1
contact1NameName for contact, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.2.1.1
contact1StateCurrent State of Contact, 0-open 1-closedro
INTEGER
.1.3.6.1.4.1.3052.40.2.1.2
contact1AlarmEnable0-alarms disabled 1-alarms enabledrw
INTEGER
.1.3.6.1.4.1.3052.40.2.1.3
contact1ActiveDirection0-alarm on open 1-alarm on closedrw
INTEGER
.1.3.6.1.4.1.3052.40.2.1.4
contact1ThresholdNumber of seconds that the contact must remain in a state before generating a trap, range 0-255rw
INTEGER
.1.3.6.1.4.1.3052.40.2.1.5
contact1ReturnNormalTrap0-return to normal traps not sent, 1-sentrw
INTEGER
.1.3.6.1.4.1.3052.40.2.1.6
contact1TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm traps.rw
INTEGER
.1.3.6.1.4.1.3052.40.2.1.7
contact1Severity1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.2.1.8
contact2
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.2.2
contact2NameName for contact, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.2.2.1
contact2StateCurrent State of Contact, 0-open 1-closedro
INTEGER
.1.3.6.1.4.1.3052.40.2.2.2
contact2AlarmEnable0-no alarms 1-alarms enabledrw
INTEGER
.1.3.6.1.4.1.3052.40.2.2.3
contact2ActiveDirection0-alarm on open 1-alarm on closedrw
INTEGER
.1.3.6.1.4.1.3052.40.2.2.4
contact2ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw
INTEGER
.1.3.6.1.4.1.3052.40.2.2.5
contact2ReturnNormalTrap0-not sent, 1-sentrw
INTEGER
.1.3.6.1.4.1.3052.40.2.2.6
contact2TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm trapsrw
INTEGER
.1.3.6.1.4.1.3052.40.2.2.7
contact2Severity1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.2.2.8
contact3
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.2.3
contact3NameName for contact, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.2.3.1
contact3StateCurrent State of Contact, 0-open 1-closedro
INTEGER
.1.3.6.1.4.1.3052.40.2.3.2
contact3AlarmEnable0-no alarms 1-alarms enabledrw
INTEGER
.1.3.6.1.4.1.3052.40.2.3.3
contact3ActiveDirection0-alarm on open 1-alarm on closedrw
INTEGER
.1.3.6.1.4.1.3052.40.2.3.4
contact3ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw
INTEGER
.1.3.6.1.4.1.3052.40.2.3.5
contact3ReturnNormalTrap0-not sent, 1-sentrw
INTEGER
.1.3.6.1.4.1.3052.40.2.3.6
contact3TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm trapsrw
INTEGER
.1.3.6.1.4.1.3052.40.2.3.7
contact3Severity1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.2.3.8
contact4
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.2.4
contact4NameName for contact, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.2.4.1
contact4StateCurrent State of Contact, 0-open 1-closedro
INTEGER
.1.3.6.1.4.1.3052.40.2.4.2
contact4AlarmEnable0-no alarms 1-alarms enabledrw
INTEGER
.1.3.6.1.4.1.3052.40.2.4.3
contact4ActiveDirection0-alarm on open 1-alarm on closedrw
INTEGER
.1.3.6.1.4.1.3052.40.2.4.4
contact4ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw
INTEGER
.1.3.6.1.4.1.3052.40.2.4.5
contact4ReturnNormalTrap0-not sent, 1-sentrw
INTEGER
.1.3.6.1.4.1.3052.40.2.4.6
contact4TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm trapsrw
INTEGER
.1.3.6.1.4.1.3052.40.2.4.7
contact4Severity1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.2.4.8
contact5
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.2.5
contact5NameName for contact, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.2.5.1
contact5StateCurrent State of Contact, 0-open 1-closedro
INTEGER
.1.3.6.1.4.1.3052.40.2.5.2
contact5AlarmEnable0-no alarms 1-alarms enabledrw
INTEGER
.1.3.6.1.4.1.3052.40.2.5.3
contact5ActiveDirection0-alarm on open 1-alarm on closedrw
INTEGER
.1.3.6.1.4.1.3052.40.2.5.4
contact5ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw
INTEGER
.1.3.6.1.4.1.3052.40.2.5.5
contact5ReturnNormalTrap0-not sent, 1-sentrw
INTEGER
.1.3.6.1.4.1.3052.40.2.5.6
contact5TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm trapsrw
INTEGER
.1.3.6.1.4.1.3052.40.2.5.7
contact5Severity1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.2.5.8
contact6
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.2.6
contact6NameName for contact, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.2.6.1
contact6StateCurrent State of Contact, 0-open 1-closedro
INTEGER
.1.3.6.1.4.1.3052.40.2.6.2
contact6AlarmEnable0-no alarms 1-alarms enabledrw
INTEGER
.1.3.6.1.4.1.3052.40.2.6.3
contact6ActiveDirection0-alarm on open 1-alarm on closedrw
INTEGER
.1.3.6.1.4.1.3052.40.2.6.4
contact6ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw
INTEGER
.1.3.6.1.4.1.3052.40.2.6.5
contact6ReturnNormalTrap0-not sent, 1-sentrw
INTEGER
.1.3.6.1.4.1.3052.40.2.6.6
contact6TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm traps.rw
INTEGER
.1.3.6.1.4.1.3052.40.2.6.7
contact6Severity1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.2.6.8
contact7
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.2.7
contact7NameName for contact, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.2.7.1
contact7StateCurrent State of Contact, 0-open 1-closedro
INTEGER
.1.3.6.1.4.1.3052.40.2.7.2
contact7AlarmEnable0-no alarms 1-alarms enabledrw
INTEGER
.1.3.6.1.4.1.3052.40.2.7.3
contact7ActiveDirection0-alarm on open 1-alarm on closedrw
INTEGER
.1.3.6.1.4.1.3052.40.2.7.4
contact7ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw
INTEGER
.1.3.6.1.4.1.3052.40.2.7.5
contact7ReturnNormalTrap0-not sent, 1-sentrw
INTEGER
.1.3.6.1.4.1.3052.40.2.7.6
contact7TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm trapsrw
INTEGER
.1.3.6.1.4.1.3052.40.2.7.7
contact7Severity1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.2.7.8
contact8
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.2.8
contact8NameName for contact, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.2.8.1
contact8StateCurrent State of Contact, 0-open 1-closedro
INTEGER
.1.3.6.1.4.1.3052.40.2.8.2
contact8AlarmEnable0-no alarms 1-alarms enabledrw
INTEGER
.1.3.6.1.4.1.3052.40.2.8.3
contact8ActiveDirection0-alarm on open 1-alarm on closedrw
INTEGER
.1.3.6.1.4.1.3052.40.2.8.4
contact8ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw
INTEGER
.1.3.6.1.4.1.3052.40.2.8.5
contact8ReturnNormalTrap0-not sent, 1-sentrw
INTEGER
.1.3.6.1.4.1.3052.40.2.8.6
contact8TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm trapsrw
INTEGER
.1.3.6.1.4.1.3052.40.2.8.7
contact8Severity1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.2.8.8
contact9
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.2.9
contact9NameName for contact, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.2.9.1
contact9StateCurrent State of Contact, 0-open 1-closedro
INTEGER
.1.3.6.1.4.1.3052.40.2.9.2
contact9AlarmEnable0-no alarms 1-alarms enabledrw
INTEGER
.1.3.6.1.4.1.3052.40.2.9.3
contact9ActiveDirection0-alarm on open 1-alarm on closedrw
INTEGER
.1.3.6.1.4.1.3052.40.2.9.4
contact9ThresholdNumber of seconds must be in a state to be 'open' or 'closed'rw
INTEGER
.1.3.6.1.4.1.3052.40.2.9.5
contact9ReturnNormalTrap0-not sent, 1-sentrw
INTEGER
.1.3.6.1.4.1.3052.40.2.9.6
contact9TrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm trapsrw
INTEGER
.1.3.6.1.4.1.3052.40.2.9.7
contact9Severity1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.2.9.8
relays
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.3
relay1
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.3.1
relay1NameName for relay, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.3.1.1
relay1CurrentState0-opened, 1-closedrw
INTEGER
.1.3.6.1.4.1.3052.40.3.1.2
relay1PowerupState0-opened, 1-closedrw
INTEGER
.1.3.6.1.4.1.3052.40.3.1.3
relay2
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.3.2
relay2NameName for relay, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.3.2.1
relay2CurrentState0-opened, 1-closedrw
INTEGER
.1.3.6.1.4.1.3052.40.3.2.2
relay2PowerupState0-opened, 1-closedrw
INTEGER
.1.3.6.1.4.1.3052.40.3.2.3
tempsensor
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.4
tempValueCurrent Temperature Value, in C or F based on 1.3.6.1.4.1.3052.40.4.10ro
INTEGER
.1.3.6.1.4.1.3052.40.4.1
tempAlarmEnable0=alarms disabled, 1=alarms enabledrw
INTEGER
.1.3.6.1.4.1.3052.40.4.2
tempHighLevelLevel at which the High alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.4.3
tempVeryHighLevelLevel at which the Very High alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.4.4
tempLowLevelLevel at which the Low alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.4.5
tempVeryLowLevelLevel at which the Very Low alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.4.6
tempAlarmThresholdSeconds must be in a range to be an alarmrw
INTEGER
.1.3.6.1.4.1.3052.40.4.7
tempReturnNormalTrap0-not sent, 1-send trap on return to normal rangerw
INTEGER
.1.3.6.1.4.1.3052.40.4.8
tempTrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm traps.rw
INTEGER
.1.3.6.1.4.1.3052.40.4.9
tempMode0=all temp readings and levels in degrees F, 1=in degrees Crw
INTEGER
.1.3.6.1.4.1.3052.40.4.10
tempHighSeverityHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.4.11
tempVeryHighSeverityVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.4.12
tempLowSeverityLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.4.13
tempVeryLowSeverityVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.4.14
tempNameName for temperature sensor, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.4.15
humiditysensor
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.5
humidityValueCurrent Relative Humidity Value (0-100%)ro
INTEGER
.1.3.6.1.4.1.3052.40.5.1
humidityAlarmEnable0=alarms disabled, 1=alarms enabledrw
INTEGER
.1.3.6.1.4.1.3052.40.5.2
humidityHighLevelLevel at which the High alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.5.3
humidityVeryHighLevelLevel at which the Very High alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.5.4
humidityLowLevelLevel at which the Low alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.5.5
humidityVeryLowLevelLevel at which the Very Low alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.5.6
humidityAlarmThresholdSeconds must be in a range to be an alarmrw
INTEGER
.1.3.6.1.4.1.3052.40.5.7
humidityReturnNormalTrap0-not sent, 1-send trap on return to normal rangerw
INTEGER
.1.3.6.1.4.1.3052.40.5.8
humidityTrapRepeat0-no repeats. 1-255 number of minutes between repeats of alarm traps.rw
INTEGER
.1.3.6.1.4.1.3052.40.5.9
humidityHighSeverityHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.5.10
humidityVeryHighSeverityVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.5.11
humidityLowSeverityLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.5.12
humidityVeryLowSeverityVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.5.13
humidityNameName for humidity sensor, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.5.14
passthrough
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.6
ptNeedPassword0-no 1-yes, is password required for passthrough connection.rw
INTEGER
.1.3.6.1.4.1.3052.40.6.1
ptSayLoginText0-no 1-yes, is passthrough login text displayed on connection.rw
INTEGER
.1.3.6.1.4.1.3052.40.6.2
ptLoginText0-24 char string which may be displayed on socket connection. Requires that ptSayLoginText be enabled to display this string.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.6.3
ptSaySiteID0-no 1-yes, is SiteID displayed on pass through connection.rw
INTEGER
.1.3.6.1.4.1.3052.40.6.4
ptUsername0-16 char string for Username used in serial passthrough connectionsrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.6.5
ptPassword0-16 char string for Password used in serial passthrough connectionsrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.6.6
ptTimeoutnumber of minutes (1-255) of idle activity (both directions) which causes disconnect. 0-neverrw
INTEGER
.1.3.6.1.4.1.3052.40.6.7
ptEscCharASCII character code (e.g, Escape=27) which if entered on the tcp port three times in a row causes disconnect. 0-nonerw
INTEGER
.1.3.6.1.4.1.3052.40.6.8
ptLfstripToPort0-no 1-yes linefeed characters received on TCP connection are removed from stream to serial portrw
INTEGER
.1.3.6.1.4.1.3052.40.6.9
ptLfstripFromPort0-no 1-yes linefeed characters received on serial port are removed from stream to TCP connectionrw
INTEGER
.1.3.6.1.4.1.3052.40.6.10
ptSerialBaudrate300 600 1200 2400 4800 9600 19200 baud are allowed valuesrw
INTEGER
.1.3.6.1.4.1.3052.40.6.11
ptSerialWordlength7 or 8 bit word selectionrw
INTEGER
.1.3.6.1.4.1.3052.40.6.12
ptSerialParityN E O are allowed values for parity (none, even, odd) [a single-character string]rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.6.13
ptTCPPortnumberIP port number for passthrough connection (range 1024-65534)rw
INTEGER
.1.3.6.1.4.1.3052.40.6.14
ftp
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.7
ftpUsername0-16 char string for Username used in ftp server for updatesrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.7.1
ftpPassword0-16 char string for Password used in ftp server for updatesrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.7.2
analog
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.8
analog1
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.8.1
analog1ValueValue of current analog reading, in 1/100 volt, +- 9999 rangero
INTEGER
.1.3.6.1.4.1.3052.40.8.1.1
analog1AlarmEnable0=no alarms, 1=send alarmsrw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.2
analog1HighLevelLevel at which the High alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.3
analog1VeryHighLevelLevel at which the Very High alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.4
analog1LowLevelLevel at which the Low alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.5
analog1VeryLowLevelLevel at which the Very Low alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.6
analog1AlarmThresholdSeconds must be in a range to be an alarmrw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.7
analog1ReturnNormalTrap0-not sent, 1-send trap on return to normal rangerw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.8
analog1TrapRepeat0-no repeats else number of minutes between repeats of traprw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.9
analog1HighSeverityHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.10
analog1VeryHighSeverityVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.11
analog1LowSeverityLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.12
analog1VeryLowSeverityVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.8.1.13
analog1NameName for analog sensor 1, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.8.1.14
analog2
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.8.2
analog2ValueValue of current analog reading, in 1/100 volt, +- 9999 rangero
INTEGER
.1.3.6.1.4.1.3052.40.8.2.1
analog2AlarmEnable0=no alarms, 1=send alarmsrw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.2
analog2HighLevelLevel at which the High alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.3
analog2VeryHighLevelLevel at which the Very High alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.4
analog2LowLevelLevel at which the Low alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.5
analog2VeryLowLevelLevel at which the Very Low alarm goes activerw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.6
analog2AlarmThresholdSeconds must be in a range to be an alarmrw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.7
analog2ReturnNormalTrap0-not sent, 1-send trap on return to normal rangerw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.8
analog2TrapRepeat0-no repeats else number of minutes between repeats of traprw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.9
analog2HighSeverityHigh Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.10
analog2VeryHighSeverityVery High Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.11
analog2LowSeverityLow Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.12
analog2VeryLowSeverityVery Low Level Severity 1-minor 2-major 3-critical 4-severe 5-warningrw
INTEGER
.1.3.6.1.4.1.3052.40.8.2.13
analog2NameName for analog sensor 2, up to 30 charactersrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.8.2.14
eventSensorStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.10
esPointTableThis table organizes 4 basic attributes of points. A point is a particular sensor on an EventSensor (e.g., temperature, humidity, contact closure 2, relay 5, etc.). The 4 point attributes are its name, whether it's in its event state, the point's value as a number and its value as a string. Points are referenced by a point index. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point).
SEQUENCE OF ESPoint
.1.3.6.1.4.1.3052.40.10.1
esPointEntryEntry for EventSensor point table
ESPoint
.1.3.6.1.4.1.3052.40.10.1.1
esIndexESThe part of the point index that refers to an EventSensor. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). This object's allowable values are 1 through 4, which refer to attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu. For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndexES=2 will now refer to that particular EventSensor.ro
INTEGER
.1.3.6.1.4.1.3052.40.10.1.1.1
esIndexPCThe part of the point index that refers to point class. The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point). The values for this object are: 1=temperature sensor 2=contact closure 3=humidity sensor 4=noise sensor 5=analog input 6=relayro
INTEGER
.1.3.6.1.4.1.3052.40.10.1.1.2
esIndexPointThe part of the point index that delineates which sensor on the EventSensor. So this combined with esIndexPC (Point Class or type) and esIndexES (which EventSensor) uniquely defines each point (sensor or relay) attached to a unit. For example, if esIndexES is 3, esIndexPC is 1 and esIndexPoint is 4 then this is the Fourth Temperature Sensor on EventSensor number 3.ro
INTEGER
.1.3.6.1.4.1.3052.40.10.1.1.3
esPointNameThe name of the point on an EventSensor. For example, 'AC temp' (in the case of the temperature sensor on an EventSensor). There can be multiple points of the same point class on an EventSensor (e.g., 8 contact closures) and multiple sensor classes on an EventSensor (e.g., temperature, contact closure, humidity). If the point referenced by a given point index is solitary (e.g., temperature sensor, because there can be only one on an EventSensor), then this object reads as '<EventSensor name>'. Setting this object for solitary point indices sets the EventSensor name only. On the other hand, if a given point is among other points of the same point class on an EventSensor, then this object reads as '<Sensor name>'. Setting this object for these NON- solitary point indices sets the sensor name only - not the EventSensor name.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.10.1.1.4
esPointInEventStateA number referring to the event state of a point on an EventSensor. This number can have different meanings depending on the point class. If the point class is temperature, humidity, or analog input, then the values of this object are: 1=very low 2=low 3=normal 4=high 5=very high For contact closures and relays the values of this object are: 1=point in event state 2=point in normal state For any point class and any point, if the event state is undefined, then the value of this object is 0. For any point class except relay, this object is read-only. For relays, setting this object to 1 puts the relay into its open state. Setting it to 2 puts the relay into its closed state.rw
INTEGER
.1.3.6.1.4.1.3052.40.10.1.1.5
esPointValueIntA number referring to the value of a point on an EventSensor. If the point class is temperature, then this object is the temperature in its configured scale (default is Fahrenheit). If the point class is contact closure or relay, then this object is either 0 (open) or 1 (closed). If the point class is humidity, then this object is the percent relative humidity. If the point class is analog input, then this object is the signed input value in tenths of the configured units. For any point class except relay, this object is read-only. For relays, setting this object to 1 closes the relay, while setting it to 0 opens it. This works regardless of the control mode of the relay.rw
INTEGER (-32768..32767)
.1.3.6.1.4.1.3052.40.10.1.1.6
esPointValueStrA string referring to the value of a point on an EventSensor. For contact closures and relays this object is either 'Open' or 'Closed'. For temperature and humidity point classes, this object is the string representation of the esPointValueInt object. For temperature, 'C' or 'F' is including in the string to indicate scale. For analog inputs, this object is the string representation of the plus/minus input in volts.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.10.1.1.7
eventSensorConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.11
esNumberEventSensorsThe number of EventSensors recognized by the s410 Range: 0-4ro
INTEGER
.1.3.6.1.4.1.3052.40.11.1
esTableThe table of what EventSensors are attached to the unit
SEQUENCE OF ESExist
.1.3.6.1.4.1.3052.40.11.2
esEntryTable entry for EventSensor table
ESExist
.1.3.6.1.4.1.3052.40.11.2.1
esIndexThis number refers to an EventSensor; it has the same meaning as the esIndexES object (see above), except that this object is used only within the esTable branch. This object's allowable values are 1 through 4, which refer to additional attached EventSensors. The number corresponding to an EventSensor is determined by the user at the initial configuration time.ro
INTEGER
.1.3.6.1.4.1.3052.40.11.2.1.1
esIDThe factory-assigned ID of the EventSensorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.11.2.1.2
esNumberTempSensorsThe number of temperature sensors on the EventSensorro
INTEGER
.1.3.6.1.4.1.3052.40.11.2.1.3
esTempReportingModeDescription of how temperature values should be interpreted.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.11.2.1.4
esNumberCCsThe number of contact closures on the EventSensor.ro
INTEGER
.1.3.6.1.4.1.3052.40.11.2.1.5
esCCReportingModeDescription of how CC values should be interpreted.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.11.2.1.6
esNumberHumidSensorsThe number of humidity sensors on the EventSensor.ro
INTEGER
.1.3.6.1.4.1.3052.40.11.2.1.7
esHumidReportingModeDescription of how humidity sensor values should be interpreted.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.11.2.1.8
esNumberNoiseSensorsThe number of noise sensors on the EventSensor.ro
INTEGER
.1.3.6.1.4.1.3052.40.11.2.1.9
esNoiseReportingModeDescription of how noise sensor values should be interpreted.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.11.2.1.10
esNumberAirflowSensorsThe number of airflow sensors on the EventSensor.ro
INTEGER
.1.3.6.1.4.1.3052.40.11.2.1.11
esAirflowReportingModeDescription of how airflow sensor values should be interpreted.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.11.2.1.12
esNumberAnalogThe number of analog inputs on the EventSensor.ro
INTEGER
.1.3.6.1.4.1.3052.40.11.2.1.13
esAnalogReportingModeDescription of how analog input values should be interpreted.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.11.2.1.14
esNumberRelayOutputsThe number of relay outputs on the EventSensorro
INTEGER
.1.3.6.1.4.1.3052.40.11.2.1.15
esRelayReportingModeDescription of how relay output values should be interpreted.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.11.2.1.16
techsupport
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.99
techsupportIPAddressMay read or Set IP Address, takes effect on restartrw
IpAddress
.1.3.6.1.4.1.3052.40.99.1
techsupportNetMaskMay read or Set NetMask, takes effect on restartrw
IpAddress
.1.3.6.1.4.1.3052.40.99.2
techsupportRouterMay read or Set Router IP Address, takes effect on restartrw
IpAddress
.1.3.6.1.4.1.3052.40.99.3
techsupportRestartReads as 0, any Write resets unit so new IP, Netmask, Router may be usedrw
INTEGER
.1.3.6.1.4.1.3052.40.99.4
techsupportSerialNumberRead/Set Serial Number, up to 8-char text string reported as 1.1rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3052.40.99.5
techsupportBoxTempEstimate of inside-the-box temp in degrees C, for heater testingro
INTEGER
.1.3.6.1.4.1.3052.40.99.6
techsupportHeaterState0-off 1-on (acutal heater pin on/off, heat may not be 100% duty cycle)ro
INTEGER
.1.3.6.1.4.1.3052.40.99.7
techsupportPSVoltsestimate of power supply input voltage (only valid on 48V build)ro
INTEGER
.1.3.6.1.4.1.3052.40.99.8
mibend
OBJECT IDENTIFIER
.1.3.6.1.4.1.3052.40.100
mibendObjectAn object after all active mib items, to help some managers compilero
INTEGER
.1.3.6.1.4.1.3052.40.100.1