RDN-SENSOR-MIB
AI MIB Summary
The RDN-SENSOR-MIB facilitates the monitoring of environmental and hardware status metrics, such as temperature, voltage, and fan speeds, on Motorola RDN sensor hardware via SNMP. This module enables system administrators to track physical device health and detect thermal or power anomalies within Motorola sensor deployments.
MIB module for Motorola hardware sensors.
Main OID:
rdnSensor.1.3.6.1.4.1.4981.5
14
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
14 total| Object Name |
|---|
rdnSensorMIB module for Motorola hardware sensors. MODULE-IDENTITY .1.3.6.1.4.1.4981.5 |
rdnSensorTableHardware Senor table. SEQUENCE OF RdnSensorEntry .1.3.6.1.4.1.4981.5.1 |
rdnSensorEntryHardware Sensor table entry. RdnSensorEntry .1.3.6.1.4.1.4981.5.1.1 |
rdnSensorIndexAn index uniquely identifying an entry
in the rdnSensorTable.ro Integer32 .1.3.6.1.4.1.4981.5.1.1.1 |
rdnSensorDescrA text description of the sensor described
by this table entry.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4981.5.1.1.2 |
rdnSensorObjectIDThe object identifier (OID) describing the
type of sensor described by this entry.ro OBJECT IDENTIFIER .1.3.6.1.4.1.4981.5.1.1.3 |
rdnSensorValueThe temperature value in degrees Celsius of
the sensor described by this entry.ro Integer32 .1.3.6.1.4.1.4981.5.1.1.4 |
rdnSensorThresholdHighThe high temperature threshold value of normal
operating conditions described by this entry.rw Integer32 .1.3.6.1.4.1.4981.5.1.1.5 |
rdnSensorThresholdLowThe low temperature threshold value of normal
operating conditions described by this entry.rw Integer32 .1.3.6.1.4.1.4981.5.1.1.6 |
rdnSensorStatusThe operational status of the sensor described
by this entry.ro Enumeration .1.3.6.1.4.1.4981.5.1.1.7 |
rdnSensorNotificationEnableThe notification enable of the sensor
described by this entry.rw Enumeration .1.3.6.1.4.1.4981.5.1.1.8 |
rdnSensorNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.4981.5.2 |
rdnSensorNotificationsPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.4981.5.2.0 |
rdnSensorThresholdExceededThe notification sent for the alarm condition
triggered when the temperature of a sensor exceeds
its low or high threshold level. NOTIFICATION-TYPE .1.3.6.1.4.1.4981.5.2.0.1 |