Home/Catalog/RBN-PVC-MIB

RBN-PVC-MIB

Defines the objects necessary to support the management of ATM, Frame Relay and IEEE 802.1Q permanent virtual circuits (PVC).
Main OID:
rbnPvcMib.1.3.6.1.4.1.2352.2.7
77
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

77 total
Object Name
rbnPvcMibDefines the objects necessary to support the management of ATM, Frame Relay and IEEE 802.1Q permanent virtual circuits (PVC).
MODULE-IDENTITY
.1.3.6.1.4.1.2352.2.7
rbnPvcMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2352.2.7.1
rbnAtmPvcConfigTableThis table contains the objects which identify and configure ATM PVCs.
SEQUENCE OF RbnAtmPvcConfigEntry
.1.3.6.1.4.1.2352.2.7.1.1
rbnAtmPvcConfigEntryA conceptual row in the rbnAtmPvcConfigTable.
RbnAtmPvcConfigEntry
.1.3.6.1.4.1.2352.2.7.1.1.1
rbnAtmPvcSlotThe chassis slot number
RbnSlot (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.1.1.1
rbnAtmPvcPortThe port number
RbnPort (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.1.1.2
rbnAtmPvcVpiThe Virtual Path Identifier for the PVC.
Unsigned32
.1.3.6.1.4.1.2352.2.7.1.1.1.3
rbnAtmPvcVciThe Virtual Channel Identifier for the PVC.
Unsigned32
.1.3.6.1.4.1.2352.2.7.1.1.1.4
rbnAtmPvcProfileNameThe profile name to use with the PVC.rw
SnmpAdminString
.1.3.6.1.4.1.2352.2.7.1.1.1.5
rbnAtmPvcEncapsulationThe encapsulation to use with the PVC.rw
RbnAtmEncapsulation
.1.3.6.1.4.1.2352.2.7.1.1.1.6
rbnAtmPvcRowStatusThe row status for creating, modifying, or deleting an entry in the table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.7.1.1.1.8
rbnAtmPvcCircuitTypeThe PVC circuit type. With respect to this mib object, only those entries whose rbnAtmPvcCircuitType has a value 'explicit' may be removed by setting rbnAtmPvcRowStatus equal to 'destroy'. A set operation with rbnAtmPvcRowStatus equal to 'destroy' on any row with rbnAtmPvcCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR.rw
RbnPvcCircuitType
.1.3.6.1.4.1.2352.2.7.1.1.1.9
rbnAtmPvcCircuitHandleThis object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the rbnBindTable defined in the RBN-BIND-MIB.ro
RbnCircuitHandle (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.1.1.10
rbnAtmPvcClearCircuitWhen this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists. When this object is set to true(1) and the encapsulation of the circuit is bridged or routed, e.g. bridge1483(2) or route1483(4), subscribers will re-authenticate after being cleared.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.7.1.1.1.11
rbnFrameRelayPvcConfigTableThis table contains the objects which identify and configure Frame Relay PVCs.
SEQUENCE OF RbnFrameRelayPvcConfigEntry
.1.3.6.1.4.1.2352.2.7.1.2
rbnFrameRelayPvcConfigEntryA conceptual row in the rbnFrameRelayPvcConfigTable.
RbnFrameRelayPvcConfigEntry
.1.3.6.1.4.1.2352.2.7.1.2.1
rbnFrameRelayPvcSlotThe chassis slot number
RbnSlot (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.2.1.1
rbnFrameRelayPvcPortThe port number
RbnPort (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.2.1.2
rbnFrameRelayPvcChannelThe channel number
Unsigned32
.1.3.6.1.4.1.2352.2.7.1.2.1.3
rbnFrameRelayPvcDLCIThe Data Link Connection Identifier
Unsigned32
.1.3.6.1.4.1.2352.2.7.1.2.1.4
rbnFrameRelayPvcProfileNameThe profile name to use with the PVC.rw
SnmpAdminString
.1.3.6.1.4.1.2352.2.7.1.2.1.5
rbnFrameRelayPvcEncapsulationThe encapsulation to use with the PVC.rw
RbnFrameRelayEncapsulation
.1.3.6.1.4.1.2352.2.7.1.2.1.6
rbnFrameRelayPvcRowStatusThe row status for creating, modifying, or deleting an entry in the table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.7.1.2.1.8
rbnFrameRelayPvcCircuitTypeThe PVC circuit type. With respect to this mib object, only those entries whose rbnFrameRelayPvcCircuitType has a value 'explicit' may be removed by setting rbnFrameRelayPvcRowStatus equal to 'destroy'. A set operation with rbnFrameRelayPvcRowStatus equal to 'destroy' on any row with rbnFrameRelayPvcCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR.rw
RbnPvcCircuitType
.1.3.6.1.4.1.2352.2.7.1.2.1.9
rbnFrameRelayPvcCircuitHandleThis object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the rbnBindTable defined in the RBN-BIND-MIB.ro
RbnCircuitHandle (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.2.1.10
rbnFrameRelayPvcClearCircuitWhen this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists. When this object is set to true(1) and the encapsulation of the circuit is bridged or routed, e.g. bridge1490(2) or route1490(4), subscribers will re-authenticate after being cleared.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.7.1.2.1.11
rbnDot1qPvcOnEthConfigTableThis table contains the objects which identify and configure IEEE 802.1Q PVCs on Ethernet ports.
SEQUENCE OF RbnDot1qPvcOnEthConfigEntry
.1.3.6.1.4.1.2352.2.7.1.3
rbnDot1qPvcOnEthConfigEntryA conceptual row in the rbnDot1qPvcOnEthConfigTable.
RbnDot1qPvcOnEthConfigEntry
.1.3.6.1.4.1.2352.2.7.1.3.1
rbnDot1qPvcOnEthSlotThe chassis slot number.
RbnSlot (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.3.1.1
rbnDot1qPvcOnEthPortThe port number.
RbnPort (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.3.1.2
rbnDot1qPvcOnEthVlanIdIEEE 802.1Q Virtual LAN (VLAN) tag value.
RbnVidOrUntagged (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.3.1.3
rbnDot1qPvcOnEthRowStatusThe row status for creating, modifying, or deleting an entry in the table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.7.1.3.1.4
rbnDot1qPvcOnEthProfileNameThe profile name to use with the PVC.rw
SnmpAdminString
.1.3.6.1.4.1.2352.2.7.1.3.1.5
rbnDot1qPvcOnEthEncapsulationThe encapsulation to use with the PVC.rw
RbnDot1qEncapsulation
.1.3.6.1.4.1.2352.2.7.1.3.1.6
rbnDot1qPvcOnEthCircuitTypeThe PVC circuit type. With respect to this mib object, only those entries whose rbnDot1qPvcOnEthCircuitType has a value 'explicit' may be removed by setting rbnDot1qPvcOnEthRowStatus equal to 'destroy'. A set operation with rbnDot1qPvcOnEthRowStatus equal to 'destroy' on any row with rbnDot1qPvcOnEthCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR.rw
RbnPvcCircuitType
.1.3.6.1.4.1.2352.2.7.1.3.1.7
rbnDot1qPvcOnEthCircuitHandleThis object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the rbnBindTable defined in the RBN-BIND-MIB.ro
RbnCircuitHandle (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.3.1.8
rbnDot1qPvcOnEthClearCircuitWhen this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.7.1.3.1.9
rbnDot1qPvcOnAtmConfigTableThis table contains the objects which identify and configure IEEE 802.1Q PVCs on ATM circuits.
SEQUENCE OF RbnDot1qPvcOnAtmConfigEntry
.1.3.6.1.4.1.2352.2.7.1.4
rbnDot1qPvcOnAtmConfigEntryA conceptual row in the rbnDot1qPvcOnAtmConfigTable.
RbnDot1qPvcOnAtmConfigEntry
.1.3.6.1.4.1.2352.2.7.1.4.1
rbnDot1qPvcOnAtmSlotThe chassis slot number.
RbnSlot (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.4.1.1
rbnDot1qPvcOnAtmPortThe port number.
RbnPort (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.4.1.2
rbnDot1qPvcOnAtmVpiThe Virtual Path Identifier for the PVC.
Unsigned32
.1.3.6.1.4.1.2352.2.7.1.4.1.3
rbnDot1qPvcOnAtmVciThe Virtual Channel Identifier for the PVC.
Unsigned32
.1.3.6.1.4.1.2352.2.7.1.4.1.4
rbnDot1qPvcOnAtmVlanIdIEEE 802.1Q Virtual LAN (VLAN) tag value.
RbnVidOrUntagged (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.4.1.5
rbnDot1qPvcOnAtmRowStatusThe row status for creating, modifying, or deleting an entry in the table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.7.1.4.1.6
rbnDot1qPvcOnAtmProfileNameThe profile name to use with the PVC.rw
SnmpAdminString
.1.3.6.1.4.1.2352.2.7.1.4.1.7
rbnDot1qPvcOnAtmEncapsulationThe encapsulation to use with the PVC.rw
RbnDot1qEncapsulation
.1.3.6.1.4.1.2352.2.7.1.4.1.8
rbnDot1qPvcOnAtmCircuitTypeThe PVC circuit type. With respect to this mib object, only those entries whose rbnDot1qPvcOnAtmCircuitType has a value 'explicit' may be removed by setting rbnDot1qPvcOnAtmRowStatus equal to 'destroy'. A set operation with rbnDot1qPvcOnAtmRowStatus equal to 'destroy' on any row with rbnDot1qPvcOnAtmCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR.rw
RbnPvcCircuitType
.1.3.6.1.4.1.2352.2.7.1.4.1.9
rbnDot1qPvcOnAtmCircuitHandleThis object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the rbnBindTable defined in the RBN-BIND-MIB.ro
RbnCircuitHandle (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.4.1.10
rbnDot1qPvcOnAtmClearCircuitWhen this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.7.1.4.1.11
rbnDot1qPvcOnFrConfigTableThis table contains the objects which identify and configure IEEE 802.1Q PVCs on ATM circuits.
SEQUENCE OF RbnDot1qPvcOnFrConfigEntry
.1.3.6.1.4.1.2352.2.7.1.5
rbnDot1qPvcOnFrConfigEntryA conceptual row in the rbnDot1qPvcOnFrConfigTable.
RbnDot1qPvcOnFrConfigEntry
.1.3.6.1.4.1.2352.2.7.1.5.1
rbnDot1qPvcOnFrSlotThe chassis slot number.
RbnSlot (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.5.1.1
rbnDot1qPvcOnFrPortThe port number.
RbnPort (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.5.1.2
rbnDot1qPvcOnFrChannelThe channel number.
Unsigned32
.1.3.6.1.4.1.2352.2.7.1.5.1.3
rbnDot1qPvcOnFrDLCIThe Data Link Connection Identifier.
Unsigned32
.1.3.6.1.4.1.2352.2.7.1.5.1.4
rbnDot1qPvcOnFrVlanIdIEEE 802.1Q Virtual LAN (VLAN) tag value.
RbnVidOrUntagged (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.5.1.5
rbnDot1qPvcOnFrRowStatusThe row status for creating, modifying, or deleting an entry in the table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.7.1.5.1.6
rbnDot1qPvcOnFrProfileNameThe profile name to use with the PVC.rw
SnmpAdminString
.1.3.6.1.4.1.2352.2.7.1.5.1.7
rbnDot1qPvcOnFrEncapsulationThe encapsulation to use with the PVC.rw
RbnDot1qEncapsulation
.1.3.6.1.4.1.2352.2.7.1.5.1.8
rbnDot1qPvcOnFrCircuitTypeThe PVC circuit type. With respect to this mib object, only those entries whose rbnDot1qPvcOnFrCircuitType has a value 'explicit' may be removed by setting rbnDot1qPvcOnFrRowStatus equal to 'destroy'. A set operation with rbnDot1qPvcOnFrRowStatus equal to 'destroy' on any row with rbnDot1qPvcOnFrCircuitType not equal to 'explicit' will result in an INCONSISTENT_VALUE_ERROR.rw
RbnPvcCircuitType
.1.3.6.1.4.1.2352.2.7.1.5.1.9
rbnDot1qPvcOnFrCircuitHandleThis object is used internally to uniquely identify a circuit. The value of this object may be used to correlate entries with those in the rbnBindTable defined in the RBN-BIND-MIB.ro
RbnCircuitHandle (RBN-TC)
.1.3.6.1.4.1.2352.2.7.1.5.1.10
rbnDot1qPvcOnFrClearCircuitWhen this object is true(1), the system will clear active subscriber sessions on the specified circuit. When false(2), there is no action taken. This object can only be written when the conceptual row exists.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.7.1.5.1.11
rbnPvcMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.2352.2.7.2
rbnPvcCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.2352.2.7.2.1
rbnPvcComplianceThe compliance statement for SNMP entities which implement the RBN-PVC-MIB.deprecated
Unknown
.1.3.6.1.4.1.2352.2.7.2.1.1
rbnPvcCompliance2The compliance statement for SNMP entities which implement the RBN-PVC-MIB.deprecated
Unknown
.1.3.6.1.4.1.2352.2.7.2.1.2
rbnPvcCompliance3The compliance statement for SNMP entities which implement the RBN-PVC-MIB.
Unknown
.1.3.6.1.4.1.2352.2.7.2.1.3
rbnPvcGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.2352.2.7.2.2
rbnAtmPvcGroupthe collection of objects which represent the ATM PVC.deprecated
Unknown
.1.3.6.1.4.1.2352.2.7.2.2.1
rbnFrameRelayPvcGroupthe collection of objects which represent the FrameRelay PVC.deprecated
Unknown
.1.3.6.1.4.1.2352.2.7.2.2.2
rbnAtmPvcGroup2The collection of objects which represent the ATM PVC.
Unknown
.1.3.6.1.4.1.2352.2.7.2.2.3
rbnFrameRelayPvcGroup2The collection of objects which represent the FrameRelay PVC.
Unknown
.1.3.6.1.4.1.2352.2.7.2.2.4
rbnDot1qPvcOnEthGroupA collection of objects providing information specific to IEEE 802.1Q PVCs on Ethernet ports.
Unknown
.1.3.6.1.4.1.2352.2.7.2.2.5
rbnDot1qPvcOnAtmGroupA collection of objects providing information specific to IEEE 802.1Q PVCs on ATM circuits.
Unknown
.1.3.6.1.4.1.2352.2.7.2.2.6
rbnDot1qPvcOnFrGroupA collection of objects providing information specific to IEEE 802.1Q PVCs on Frame Relay circuits.
Unknown
.1.3.6.1.4.1.2352.2.7.2.2.7
rbnPvcMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.2352.2.7.3
RBN-PVC-MIB - SNMP MIB Reference | MIBs Explorer