Home/Catalog/RBN-OPTICAL-TRANSCEIVER-MIB

RBN-OPTICAL-TRANSCEIVER-MIB

AI MIB Summary

The RBN-OPTICAL-TRANSCEIVER-MIB enables SNMP-based monitoring of optical transceiver parameters, including optical power levels, temperature, and bias current, specifically for Line Card ports on SSR hardware. This module facilitates real-time fault detection and performance analysis of fiber optic interfaces within the SSR platform.

The MIB used to manage the Optical Transceivers in Line Card ports in SSR
Main OID:
rbnOpticalTransceiver.1.3.6.1.4.1.2352.2.50
48
Objects
Active
Status
10
Dependencies

Imported Objects

Objects

48 total
Object Name
rbnOpticalTransceiverAlarmAn rbnOpticalTransceiverAlarm notification signifies that an alarm has been raised or cleared on a Optical Transceiver
NOTIFICATION-TYPE
.1.3.6.1.4.1.2352.2.49.0.2
rbnOpticalTransceiverLaneAlarmAn rbnOpticalTransceiverLaneAlarm notification signifies that an alarm has been raised or cleared in a lane on a Optical Transceiver
NOTIFICATION-TYPE
.1.3.6.1.4.1.2352.2.49.0.3
rbnOpticalTransceiverMonMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.2352.2.49.2.3
rbnOpticalTransceiverMonMIBNotificationGroupA collection of notifications providing Optical Transceiver fault condition
Unknown
.1.3.6.1.4.1.2352.2.49.2.3.2
rbnOpticalTransceiverMonMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.2352.2.49.2.4
rbnOpticalTransceiverMonMIBComplianceThe compliance statement for the OpticalTransceiver MIB
Unknown
.1.3.6.1.4.1.2352.2.49.2.4.1
rbnOpticalTransceiverThe MIB used to manage the Optical Transceivers in Line Card ports in SSR
MODULE-IDENTITY
.1.3.6.1.4.1.2352.2.50
rbnOpticalTransceiverDetails
OBJECT IDENTIFIER
.1.3.6.1.4.1.2352.2.50.1
rbnOpticalTransceiverPortTableThis table contains the ports with optical transceivers and corresponding parameters
SEQUENCE OF RbnOpticalTransceiverPortEntry
.1.3.6.1.4.1.2352.2.50.1.1
rbnOpticalTransceiverPortEntryLine Card port optical transceiver parameter description.
RbnOpticalTransceiverPortEntry
.1.3.6.1.4.1.2352.2.50.1.1.1
rbnOpticalTransceiverCardSlotThe chassis slot number in which the card is present where the Optical Transceiver plugged in.ro
RbnSlot (RBN-TC)
.1.3.6.1.4.1.2352.2.50.1.1.1.1
rbnOpticalTransceiverPortThe port number where the Optical Transceiver plugged in.ro
RbnPort (RBN-TC)
.1.3.6.1.4.1.2352.2.50.1.1.1.2
rbnOpticalTransceiverTypeType and category of Optical Transceiverro
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.3
rbnOpticalTransceiverMediaTypeOptical Transceiver Media Typero
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.4
rbnOpticalTransceiverRbnEricssonApprovedIs the Optical Transceiver n this port approved by Ericsson, Yes/No?ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.50.1.1.1.5
rbnOpticalTransceiverDiagMonitoringIs Optical Transceiver Diag Monitoring On or Off?ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2352.2.50.1.1.1.6
rbnOpticalTransceiverCLEIcodeOptical Transceiver Common Language Equipment Identifier (CLEI) code.ro
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.7
rbnOpticalTransceiverSerialNoOptical Transceiver serial numberro
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.8
rbnOpticalTransceiverFrequencyOptical Transceiver Frequencyro
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.9
rbnOpticalTransceiverWaveLengthOptical Transceiver Wave Lengthro
RbnOpticalTransceiverParamWaveLength
.1.3.6.1.4.1.2352.2.50.1.1.1.10
rbnOpticalTransceiverAdditionalFeaturesOptical Transceiver Additional Features such as, Is Optical Transceiver OTN capable? and/or Is Optical Transceiver Tunable?ro
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.11
rbnOpticalTransceiverFrequencyStartFrequency Start for tunable optical transceiver. Not applicable if optical transceiver is not tunablero
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.12
rbnOpticalTransceiverFrequencyEndFrequency End for tunable optical transceiver. Not applicable if optical transceiver is not tunablero
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.13
rbnOpticalTransceiverFrequencySpacingFrequency Spacing for tunable optical transceiver. Not applicable if optical transceiver is not tunablero
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.14
rbnOpticalTransceiverOTNFramerFramer of OTN if optical transceiver is OTN capable. Not applicable if optical transceiver is not OTN capablero
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.15
rbnOpticalTransceiverOTNFECFEC of OTN if optical transceiver is OTN capable. Not applicable if optical transceiver is not OTN capablero
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.16
rbnOpticalTransceiverPowerLevelOptical Transceiver Power Levelro
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.1.1.17
rbnOpticalTransceiverActiveAlarmCountNumber of alarms active on the Optical Transceiverro
INTEGER
.1.3.6.1.4.1.2352.2.50.1.1.1.18
rbnOpticalTransceiverParamBitMaskThis Bit Mask indicates which values are valid for RbnOpticalTransceiverParamType in rbnOpticalTransceiverParamTable: 0x0001 optical transceiver txpower valid 0x0002 optical transceiver rxpower valid 0x0004 optical transceiver temperature valid 0x0008 optical transceiver laserBiasCurrent valid 0x0010 optical transceiver soaBiasCurrent valid 0x0020 optical transceiver Vcc valid 0x0040 optical transceiver aux1 valid 0x0080 optical transceiver aux2 valid 0x0100 optical transceiver lane txpower valid 0x0200 optical transceiver lane rxpower valid 0x0400 optical transceiver lane temperature valid 0x0800 optical transceiver lane laserBiasCurrent validro
Integer32
.1.3.6.1.4.1.2352.2.50.1.1.1.19
rbnOpticalTransceiverLaneCountNumber of Lanes in optical transceiverro
INTEGER
.1.3.6.1.4.1.2352.2.50.1.1.1.20
rbnOpticalTransceiverParamTableThis table provides objects to monitor optical transceiver parameters in a network element. It also provides objects for monitoring high and low warning and alarm threshold on these monitored parameters.
SEQUENCE OF RbnOpticalTransceiverParamEntry
.1.3.6.1.4.1.2352.2.50.1.2
rbnOpticalTransceiverParamEntryOpticalTransceiver Parameter Entries in Table
RbnOpticalTransceiverParamEntry
.1.3.6.1.4.1.2352.2.50.1.2.1
rbnOpticalTransceiverParamTypeThis object specifies the optical parameter type that is being monitored in this entry.ro
RbnOpticalTransceiverParamType
.1.3.6.1.4.1.2352.2.50.1.2.1.1
rbnOpticalTransceiverParamDescriptionThis object specifies the optical parameter description including units that is being monitored in this entry.ro
OCTET STRING
.1.3.6.1.4.1.2352.2.50.1.2.1.2
rbnOpticalTransceiverCurrentValueThe current value of tx power, rx power, temperature, bias current and Vccro
RbnOpticalTransceiverParameterValue
.1.3.6.1.4.1.2352.2.50.1.2.1.3
rbnOpticalTransceiverMaxAlarmValueThe alarm high threshold value of tx power, rx power, temperature, bias current and Vccro
RbnOpticalTransceiverParameterValue
.1.3.6.1.4.1.2352.2.50.1.2.1.4
rbnOpticalTransceiverMaxWarningValueThe warning high threshold value of tx power, rx power, temperature, bias current and Vccro
RbnOpticalTransceiverParameterValue
.1.3.6.1.4.1.2352.2.50.1.2.1.5
rbnOpticalTransceiverMinAlarmValueThe alarm low threshold value of tx power, rx power, temperature, bias current and Vccro
RbnOpticalTransceiverParameterValue
.1.3.6.1.4.1.2352.2.50.1.2.1.6
rbnOpticalTransceiverMinWarningValueThe warning low threshold value of tx power, rx power, temperature, bias current and Vccro
RbnOpticalTransceiverParameterValue
.1.3.6.1.4.1.2352.2.50.1.2.1.7
rbnLaneInOpticalTransceiverParamTableThis table provides objects to monitor optical transceiver parameters in a network element. It also provides objects for monitoring high and low warning and alarm threshold on these monitored parameters.
SEQUENCE OF RbnLaneInOpticalTransceiverParamEntry
.1.3.6.1.4.1.2352.2.50.1.3
rbnLaneInOpticalTransceiverParamEntryLaneInOpticalTransceiver Parameter Entries in Table
RbnLaneInOpticalTransceiverParamEntry
.1.3.6.1.4.1.2352.2.50.1.3.1
rbnLaneInOpticalTransceiverThis object specifies the optical transceiver lane that is being monitored in this entry.ro
Integer32
.1.3.6.1.4.1.2352.2.50.1.3.1.1
rbnLaneInOpticalTransceiverParamTypeThis object specifies the optical parameter type that is being monitored in this entry.ro
RbnLaneInOpticalTransceiverParamType
.1.3.6.1.4.1.2352.2.50.1.3.1.2
rbnLaneInOpticalTransceiverCurrentValueThe current value of tx power, rx power, temperature, bias current and Vccro
RbnLaneInOpticalTransceiverParameterValue
.1.3.6.1.4.1.2352.2.50.1.3.1.3
rbnLaneInOpticalTransceiverMaxAlarmValueThe alarm high threshold value of tx power, rx power, temperature, bias current and Vccro
RbnLaneInOpticalTransceiverParameterValue
.1.3.6.1.4.1.2352.2.50.1.3.1.4
rbnLaneInOpticalTransceiverMaxWarningValueThe warning high threshold value of tx power, rx power, temperature, bias current and Vccro
RbnLaneInOpticalTransceiverParameterValue
.1.3.6.1.4.1.2352.2.50.1.3.1.5
rbnLaneInOpticalTransceiverMinAlarmValueThe alarm low threshold value of tx power, rx power, temperature, bias current and Vccro
RbnLaneInOpticalTransceiverParameterValue
.1.3.6.1.4.1.2352.2.50.1.3.1.6
rbnLaneInOpticalTransceiverMinWarningValueThe warning low threshold value of tx power, rx power, temperature, bias current and Vccro
RbnLaneInOpticalTransceiverParameterValue
.1.3.6.1.4.1.2352.2.50.1.3.1.7