RBN-ATM-PROFILE-MIB
AI MIB Summary
The RBN-ATM-PROFILE-MIB enables monitoring and management of Asynchronous Transfer Mode (ATM) traffic descriptor parameters, specifically instrumenting non-standard profile attributes such as peak cell rate, sustainable cell rate, and maximum burst size for Redback Networks ATM interfaces. This module extends standard MIB capabilities to track granular ATM profile configurations and performance deviations not covered by generic standards-track definitions.
The MIB for instrumenting parameters associated with an ATM profile (traffic descriptor) beyond those instrumented by standards-track MIBs.
Main OID:
rbnAtmProfileMIB.1.3.6.1.4.1.2352.2.2
11
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
11 total| Object Name |
|---|
rbnAtmProfileMIBThe MIB for instrumenting parameters associated with
an ATM profile (traffic descriptor) beyond those
instrumented by standards-track MIBs. MODULE-IDENTITY .1.3.6.1.4.1.2352.2.2 |
rbnAtmProfileMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2352.2.2.1 |
rbnAtmProfileTableThis table provides a collection of auxiliary
objects providing parameters for atm profiles. SEQUENCE OF RbnAtmProfileEntry .1.3.6.1.4.1.2352.2.2.1.1 |
rbnAtmProfileEntryEach entry in this table represents a profile. RbnAtmProfileEntry .1.3.6.1.4.1.2352.2.2.1.1.1 |
rbnAtmProfileNameThe textual handle assigned to an instance of
the rbnAtmProfileTable (and via augmentation, the
atmTrafficDescrParamTable). Using a textual handle
instead of an arbitrary integer (such as
atmTrafficDescrParamIndex) allows a configuration
to contain human-friendly cross-references to the
profiles from those places where they are used,
such as in circuit configuration tables.rw AtmProfileName .1.3.6.1.4.1.2352.2.2.1.1.1.1 |
rbnAtmCountersEnabledAn indication as to whether circuits configured
with this profile should enable per-circuit
statistical counters. An ATM circuit will only
keep per-circuit statistical counters if this
object is set to true(1) in the profile being used
by the circuit.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2352.2.2.1.1.1.2 |
rbnAtmCellLossPriorityAn indication as to whether circuits configured
with this profile should enable the Cell Loss
Priority (CLP) bit on transmitted cells. If the profile
being used by a circuit has this object set to true(1),
then all cells transmitted on that circuit will have the
CLP bit set.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2352.2.2.1.1.1.3 |
rbnAtmTransmitBuffersThis object limits the total number of outbound
transmit packet buffers that may be consumed by
the circuit that references the profile.
Note well that this parameter should be used with
caution. Improper setting can have severe
consequences on overall system performance.rw Integer32 .1.3.6.1.4.1.2352.2.2.1.1.1.4 |
rbnAtmProfileMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.2352.2.2.2 |
rbnAtmProfileMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.2352.2.2.2.1 |
rbnAtmProfileMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.2352.2.2.2.2 |