RADLAN-POE-MIB
AI MIB Summary
The RADLAN-POE-MIB module enables monitoring and management of Power over Ethernet (PoE) allocation limits on RADLAN network switches by exposing the maximum power allocation threshold for each port. This metric allows network administrators to enforce power budgets and prevent over-subscription on PoE-enabled interfaces.
Add a new field in the PoE MIB to indicate Max power allocation allowed
Main OID:
rlPoe.1.3.6.1.4.1.89.108
33
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
33 total| Object Name |
|---|
rlPoeAdd a new field in the PoE MIB to indicate Max power allocation allowed MODULE-IDENTITY .1.3.6.1.4.1.89.108 |
SNMPv2-TCAdd a new field in the PoE MIB to indicate Max power allocation allowed Unknown .1.3.6.1.4.1.89.108 |
rlPethPsePortTableThe table listing additional information for Power Over Ethernet ports. SEQUENCE OF RlPethPsePortEntry .1.3.6.1.4.1.89.108.1 |
rlPethPsePortEntryAn entry in the rlPethPsePortTable. RlPethPsePortEntry .1.3.6.1.4.1.89.108.1.1 |
rlPethPsePortGroupIndexThis variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices.
Furthermore, the same value MUST be used in this variable,
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
to refer to a given box in a stack or module in the rack. INTEGER .1.3.6.1.4.1.89.108.1.1.1 |
rlPethPsePortIndexThis variable uniquely identifies the power Ethernet PSE
port within group pethPsePortGroupIndex to which the
power Ethernet PSE entry is connected. INTEGER .1.3.6.1.4.1.89.108.1.1.2 |
rlPethPsePortOutputVoltageThis variable indicates on the output voltage level in milli volts from rlPethPsePortIndex.ro INTEGER .1.3.6.1.4.1.89.108.1.1.3 |
rlPethPsePortOutputCurrentThis variable indicates on the output current level in milli amper from rlPethPsePortIndex.ro INTEGER .1.3.6.1.4.1.89.108.1.1.4 |
rlPethPsePortOutputPowerThis variable indicates on the output power level in milli watts from rlPethPsePortIndex.ro INTEGER .1.3.6.1.4.1.89.108.1.1.5 |
rlPethPsePortPowerLimitThis variable indicates on the user configured power level in milli watts which is available from rlPethPsePortIndex.rw INTEGER .1.3.6.1.4.1.89.108.1.1.6 |
rlPethPsePortStatusThis variable indicates on the hardware status of rlPethPsePortIndex.ro INTEGER .1.3.6.1.4.1.89.108.1.1.7 |
rlPethPsePortStatusDescriptionThis variable indicates the description of the hardware status of rlPethPsePortIndex.ro DisplayString .1.3.6.1.4.1.89.108.1.1.8 |
rlPethPsePortOperPowerLimitThis variable indicates the maximum power level in milli watts which is available from rlPethPsePortIndex.ro INTEGER .1.3.6.1.4.1.89.108.1.1.9 |
rlPethPsePortSupportPoePlusThis variable indicates if the port supports poe plus.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.89.108.1.1.10 |
rlPethPsePortTimeRangeNameThis variable is used to bind PoE port to time range.rw DisplayString .1.3.6.1.4.1.89.108.1.1.11 |
rlPethPsePortOperStatusThis Read-Only variable indicates PoE port current status affected by time range active/inactive and admin status.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.89.108.1.1.12 |
rlPethPsePortMaxPowerAllocAllowedThis variable indicates the maximum power allocation allowed per port (including wire power loses) in milli-watts which is available from rlPethPsePortIndex.ro INTEGER .1.3.6.1.4.1.89.108.1.1.13 |
rlPethPsePortSupportPoeThis variable indicates if the port is a poe portro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.89.108.1.1.14 |
rlPethMainPseTableThe table listing additional read - only information for Power Over Ethernet. SEQUENCE OF RlPethMainPseEntry .1.3.6.1.4.1.89.108.2 |
rlPethMainPseEntryAn entry in the rlPethMainPseTable. RlPethMainPseEntry .1.3.6.1.4.1.89.108.2.1 |
rlPethMainPseGroupIndexThis variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices.
Furthermore, the same value MUST be used in this variable,
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
to refer to a given box in a stack or module in the rack. INTEGER .1.3.6.1.4.1.89.108.2.1.1 |
rlPethMainPseSwVersionThis variable identifies the MCU SW version.ro DisplayString .1.3.6.1.4.1.89.108.2.1.2 |
rlPethMainPseHwVersionThis variable identifies the MCU HW version.ro DisplayString .1.3.6.1.4.1.89.108.2.1.3 |
rlPethMainPseHwTypeThis variable identifies the MCU HW type (enhanced, plus, none).ro Enumeration .1.3.6.1.4.1.89.108.2.1.4 |
rlPethMainPsePowerGuardBandThis variable identifies the guard band in [W] for not connecting
additional ports.ro INTEGER .1.3.6.1.4.1.89.108.2.1.5 |
rlPethPowerPseTableThe table listing additional read-write information for Power Over Ethernet. SEQUENCE OF RlPethPowerPseEntry .1.3.6.1.4.1.89.108.3 |
rlPethPowerPseEntryAn entry in the rlPethPowerPseTable. RlPethPowerPseEntry .1.3.6.1.4.1.89.108.3.1 |
rlPethPowerPseGroupIndexThis variable uniquely identifies the group
containing the port to which a power Ethernet PSE is
connected. Group means box in the stack, module in a
rack and the value 1 MUST be used for non-modular devices.
Furthermore, the same value MUST be used in this variable,
PethPowerPseGroupIndex, and pethNotificationControlGroupIndex
to refer to a given box in a stack or module in the rack. INTEGER .1.3.6.1.4.1.89.108.3.1.1 |
rlPethPowerPsePowerThis variable identifies the maximum power in [W] supplied by PSE.rw Enumeration .1.3.6.1.4.1.89.108.3.1.2 |
rlPethPowerPseRpsPowerThis variable identifies the maximum power in [W] supplied by PSE + RPS.rw Enumeration .1.3.6.1.4.1.89.108.3.1.3 |
rlPethPowerPsePowerManagementModeThis variable identifies power management mode.rw Enumeration .1.3.6.1.4.1.89.108.3.1.4 |
rlPethPowerPsedisconnectMethodThis variable identifies disconnect method.rw Enumeration .1.3.6.1.4.1.89.108.3.1.5 |
rlPethPowerPseTemperatureSensorThis variable identifies the pd temperature sensor.ro INTEGER (-200..200) .1.3.6.1.4.1.89.108.3.1.6 |