The RADLAN-PHY-MIB enables monitoring and management of Layer 1 physical interface states, link status, and signal integrity metrics for Radlan network hardware. It provides vendor-specific access to physical layer diagnostics for troubleshooting connectivity and signal degradation on Radlan-supported devices.

The MIB module describes the private MIB for testing Layer1 interfaces supported by Radlan's software and products.
Main OID:
rlPhy.1.3.6.1.4.1.89.90
14
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

14 total
Object Name
rlPhyThe MIB module describes the private MIB for testing Layer1 interfaces supported by Radlan's software and products.
MODULE-IDENTITY
.1.3.6.1.4.1.89.90
IMPORTSThe MIB module describes the private MIB for testing Layer1 interfaces supported by Radlan's software and products.
Unknown
.1.3.6.1.4.1.89.90
rlPhyTest
OBJECT IDENTIFIER
.1.3.6.1.4.1.89.90.1
rlPhyTestSetTable
SEQUENCE OF RlPhyTestSetEntry
.1.3.6.1.4.1.89.90.1.1
rlPhyTestSetEntryAn entry containing objects for invoking tests on an interface.
RlPhyTestSetEntry
.1.3.6.1.4.1.89.90.1.1.1
rlPhyTestSetTypeA control variable used to start operator initiated interface tests.1 indicates that no test has been initiated. Only operator initiated interface tests can be set to this variable.rw
RlPhyTestType
.1.3.6.1.4.1.89.90.1.1.1.1
rlPhyTestGetTable
SEQUENCE OF RlPhyTestGetEntry
.1.3.6.1.4.1.89.90.1.2
rlPhyTestGetEntryAn entry containing results of tests on an interface.
RlPhyTestGetEntry
.1.3.6.1.4.1.89.90.1.2.1
rlPhyTestGetTypeA control variable used to, 1 to indicate that this test can be done on the specified port, 2 to initiate the test whenever the user wishesro
RlPhyTestType
.1.3.6.1.4.1.89.90.1.2.1.1
rlPhyTestGetStatusThis object contains the status of the most recently requested test for operator initiated tests or the value none(1) if no tests have been requested since the last reset. For non operator initiated tests the value is always none(1). Note that this facility provides no provision for saving the results of one test when starting another, as could be required if used by multiple managers concurrently.ro
Enumeration
.1.3.6.1.4.1.89.90.1.2.1.2
rlPhyTestGetResultThis object holds the test resultro
INTEGER
.1.3.6.1.4.1.89.90.1.2.1.3
rlPhyTestGetUnitsThe test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7).ro
Enumeration
.1.3.6.1.4.1.89.90.1.2.1.4
rlPhyTestGetAlarmThis object hold the Alarm for this Entry. only Test that have can have alarms use this field, other holds the Value notRelevant(1)ro
Enumeration
.1.3.6.1.4.1.89.90.1.2.1.5
rlPhyTestGetTimeStampThe time in string (formated DD-MMM-YYYY HH:MM:SS e.g 14-Apr-2002 10:33:31)ro