Home/Catalog/PRVT-CES-MIB

PRVT-CES-MIB

This module includes configuration parameters for DS1 modules not included in DS1-MIB.
Main OID:
prvtCESMib.1.3.6.1.4.1.5205.2.111
104
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

104 total
Object Name
prvtCESMibThis module includes configuration parameters for DS1 modules not included in DS1-MIB.
MODULE-IDENTITY
.1.3.6.1.4.1.5205.2.111
prvtCESNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.5205.2.111.0
prvtCESDsx1AlarmThis notification is sent when the value of a TDM port error condition statistic has exceeded the configured threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.5205.2.111.0.1
prvtCESModuleAvailableprvtCESModuleAvailable trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.5205.2.111.0.2
prvtCESModuleUnAvailableDueExtractprvtCESModuleUnAvailableDueExtract trap.
NOTIFICATION-TYPE
.1.3.6.1.4.1.5205.2.111.0.3
prvtCESModuleUnAvailableDueReloadprvtCESModuleUnAvailableDueReload trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.5205.2.111.0.4
prvtCESObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.5205.2.111.1
prvtCESDsx1ExtTableThis table contains object for configuring DS1 interfaces, not supported in dsx1ConfigTable.
SEQUENCE OF PrvtCESDsx1ExtEntry
.1.3.6.1.4.1.5205.2.111.1.1
prvtCESDsx1ExtEntryprvtCESDsx1ExtEntry
PrvtCESDsx1ExtEntry
.1.3.6.1.4.1.5205.2.111.1.1.1
prvtCESE1ImpedanceThis object configures temination impedance for TDM ports if the line type is E1.rw
E1Impedance
.1.3.6.1.4.1.5205.2.111.1.1.1.1
prvtCEST1GainLimitThis object configures Tx or Rx gain limit for TDM ports if the line type is T1.rw
T1GainLimit
.1.3.6.1.4.1.5205.2.111.1.1.1.2
prvtCESPortShutdownShutdown TDM port.rw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.1.1.3
prvtCESPortLineTypeAdditional line types. For reference see object dsx1LineTyperw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.1.1.4
prvtCEST1LongCableLengthLong cable length options for T1 mode.rw
T1LongCableLength
.1.3.6.1.4.1.5205.2.111.1.1.1.5
prvtCESPortOperStatusTDM link state.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.1.1.6
prvtCESClearPortStatisticsClear port statistics.rw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.1.1.7
prvtCESServiceClockService Clock available only for DS1 interface.rw
ServiceClock
.1.3.6.1.4.1.5205.2.111.1.1.1.8
prvtCESModuleConfTableThis table contains object for configuring options that are applied to the entire module.
SEQUENCE OF PrvtCESModuleConfEntry
.1.3.6.1.4.1.5205.2.111.1.2
prvtCESModuleConfEntryprvtCESModuleConfEntry
PrvtCESModuleConfEntry
.1.3.6.1.4.1.5205.2.111.1.2.1
prvtCESModuleIndexIndex of each CES module installed.ro
Integer32
.1.3.6.1.4.1.5205.2.111.1.2.1.1
prvtCESModuleLineTypeLine mode for the module.rw
CESLineType
.1.3.6.1.4.1.5205.2.111.1.2.1.2
prvtCESModuleTxClockConfigures Transmit Source Clock for the module.rw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.3
prvtCESModuleTxBackupClockConfigures Backup Clock for the module.rw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.4
prvtCESModuleConfigWhen this object is set to applyConfiguration(2), the module is restarted and the changes in dsx1ConfigTable or prvtCESConfTable are applied. The object must be set to rejectConfiguration(3) to remove unapplied changes. If the object is set to restart(4), the module is restarted with applying the changes. This object always returns a value of noop(1) when get.rw
ConfigAction
.1.3.6.1.4.1.5205.2.111.1.2.1.5
prvtCESModuleIPAddressThe CES Module IP address after configuration is applied.rw
IpAddress
.1.3.6.1.4.1.5205.2.111.1.2.1.6
prvtCESModuleIPAddressMaskThe CES Module IP address mask after configuration is applied.rw
IpAddress
.1.3.6.1.4.1.5205.2.111.1.2.1.7
prvtCESModuleGatewayCES Module Gateway after configuration is applied.rw
IpAddress
.1.3.6.1.4.1.5205.2.111.1.2.1.8
prvtCESModuleUpTimeCES Up Timero
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.5205.2.111.1.2.1.9
prvtCESModuleMACAddressCES MAC Addressro
OCTET STRING
.1.3.6.1.4.1.5205.2.111.1.2.1.10
prvtCESModuleHardwareRevisionCES Hardware revisionro
OCTET STRING
.1.3.6.1.4.1.5205.2.111.1.2.1.11
prvtCESModuleFirmwareVersionCES Firmware revisionro
OCTET STRING
.1.3.6.1.4.1.5205.2.111.1.2.1.12
prvtCESModuleClearCircuitStatisticsClear circuits statistics.rw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.13
prvtCESModuleLbitEnable/disable L bit set upon AIS defect detection, in structure agnostic mode.rw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.14
prvtCESModulePolicyLopsControls policy lops. Object does not require module to be restarted.rw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.15
prvtCESModulePolicyLbitControls policy lbit. Object does not require module to be restarted.rw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.16
prvtCESModulePolicyRbitControls policy rbit. Object does not require module to be restarted.rw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.17
prvtCESModulePolicyRdControls policy rd. Object does not require module to be restarted.rw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.18
prvtCESModulePolicyIdlePatternControls policy idle pattern. Object does not require module to be restarted.rw
Unsigned32
.1.3.6.1.4.1.5205.2.111.1.2.1.19
prvtCESModulePolicyIdleSignallingControls policy idle signalling. Object does not require module to be restarted.rw
Unsigned32
.1.3.6.1.4.1.5205.2.111.1.2.1.20
prvtCESModulePolicyLopsEnterControls the number of consecutive missed packets required to enter LOPS state. Object does not require module to be restarted.rw
Integer32
.1.3.6.1.4.1.5205.2.111.1.2.1.21
prvtCESModulePolicyLopsExitControls the number of consecutive missed packets required to exit LOPS state. Object does not require module to be restarted.rw
Integer32
.1.3.6.1.4.1.5205.2.111.1.2.1.22
prvtCESModulePolicyuUnstrLbitIf a packet is received with L bit set, and the payload is present (not suppressed), one of the following is sent to the TDM line, according to a globally configurable unstructured L-flag policy: The AIS pattern all-one The received payload as-is nonerw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.23
prvtCESModulePolicyuStrReplaceIf a missing packet is detected, one of the following is sent to the TDM line, according to a globally configurable structured missing packet replacement policy: The AIS pattern all-one on the relevant timeslots The configured IDLE patternrw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.24
prvtCESModulePolicyuUnstrReplaceIf a missing packet is detected, one of the following is sent to the TDM line, according to a globally configurable unstructured missing packet replacement policy: The AIS pattern all-one The configured IDLE patternrw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.25
prvtCESModulePolicyuUnstrLopsIf a CES circuit enters the LOPS state, one of the following is sent to the TDM line, according to a globally configurable unstructured missing packet replacement policy: The AIS pattern all-one The contents of the jitter buffer - nonerw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.2.1.26
prvtCESModuleServiceClockClock mode for CES modulerw
ServiceClock
.1.3.6.1.4.1.5205.2.111.1.2.1.27
prvtCESModulePolicyuUnstrReplacePatternUnstructured packet replace policy pattern numberrw
Integer32
.1.3.6.1.4.1.5205.2.111.1.2.1.28
prvtCESUnappTableThis table displays CES module configuration which will take effect after prvtCESModuleConf is set to applyConfiguration(2).
SEQUENCE OF PrvtCESUnappEntry
.1.3.6.1.4.1.5205.2.111.1.3
prvtCESUnappEntryprvtCESUnappEntry
PrvtCESUnappEntry
.1.3.6.1.4.1.5205.2.111.1.3.1
prvtCESUnappLineTypeThe value of dsx1LineType before configuration is applied.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.3.1.1
prvtCESUnappLineCodingThe value of dsx1LineCoding before configuration is applied.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.3.1.2
prvtCESUnappLoopbackConfigThe value of dsx1LoopbackConfig before configuration is applied.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.3.1.3
prvtCESUnappSignalModeThe value of dsx1SignalMode before configuration is applied.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.3.1.4
prvtCESUnappTransmitClockSourceThe value of dsx1TransmitClockSource before configuration is applied.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.3.1.5
prvtCESUnappTransmitClockBackupThe value of dsx1TransmitClockBackup before configuration is applied.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.3.1.6
prvtCESUnappLineLengthThe value of dsx1LineLength before configuration is applied.ro
Integer32
.1.3.6.1.4.1.5205.2.111.1.3.1.7
prvtCESUnappLineModeThe value of dsx1LineMode before configuration is applied.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.3.1.8
prvtCESUnappLineBuildOutThe value of dsx1LineBuildOut before configuration is applied.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.3.1.9
prvtCESUnappE1ImpedanceThe value of prvtCESE1Impedance before configuration is applied.ro
E1Impedance
.1.3.6.1.4.1.5205.2.111.1.3.1.10
prvtCESUnappT1GainLimitThe value of prvtCEST1GainLimit before configuration is applied.ro
T1GainLimit
.1.3.6.1.4.1.5205.2.111.1.3.1.11
prvtCESUnappIPAddressThe CES Module IP address before configuration is applied.ro
IpAddress
.1.3.6.1.4.1.5205.2.111.1.3.1.12
prvtCESUnappIPAddressMaskThe CES Module IP address mask before configuration is applied.ro
IpAddress
.1.3.6.1.4.1.5205.2.111.1.3.1.13
prvtCESUnappGatewayThe CES Module Gateway before configuration is applied.ro
IpAddress
.1.3.6.1.4.1.5205.2.111.1.3.1.14
prvtCESDsx1AlarmTableThis table contains object for configuring and displaying TDM ports TCA thresholds.
SEQUENCE OF PrvtCESDsx1AlarmEntry
.1.3.6.1.4.1.5205.2.111.1.4
prvtCESDsx1AlarmEntryprvtCESDsx1AlarmEntry
PrvtCESDsx1AlarmEntry
.1.3.6.1.4.1.5205.2.111.1.4.1
prvtCESDsx1AlarmPortThe DS1 port for which this alarm is configured.
Integer32
.1.3.6.1.4.1.5205.2.111.1.4.1.1
prvtCESDsx1AlarmIndexAn integer uniquely identifying an alarm entry.
Gauge32
.1.3.6.1.4.1.5205.2.111.1.4.1.2
prvtCESDsx1AlarmVariableThe OID of the variable whose value is being monitored. Depending on the time interval, the error condition and the ifIndex of the TDM interface, this points to an object from an entry in dsx1CurrentTable or dsx1TotalTable.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.5205.2.111.1.4.1.3
prvtCESDsx1AlarmThresholdThe alarm condition threshold for this alarm entry. The alarm is triggered if the value of the object pointed by prvtCESDsx1AlarmVariable remains above this threshold for more than 3 seconds.rw
Integer32
.1.3.6.1.4.1.5205.2.111.1.4.1.4
prvtCESDsx1AlarmValueThe value of the object pointed to by prvtCESDsx1AlarmVariable, present for notification purposes.ro
Integer32
.1.3.6.1.4.1.5205.2.111.1.4.1.5
prvtCESAlarmMonitorCES alarm monitorrw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.5
prvtCESCICTableThis table contains objects for configuring Clock Input Controller.
SEQUENCE OF PrvtCESCICEntry
.1.3.6.1.4.1.5205.2.111.1.6
prvtCESCICEntryprvtCESCICEntry
PrvtCESCICEntry
.1.3.6.1.4.1.5205.2.111.1.6.1
prvtCESCICModuleIdSlot of CES module installed.
Integer32
.1.3.6.1.4.1.5205.2.111.1.6.1.1
prvtCESCICNumberAn integer uniquely identifying a Clock Input Controller.
Gauge32
.1.3.6.1.4.1.5205.2.111.1.6.1.2
prvtCESCICClockNumberThis variable indicates the index of the clock the clock input controller belongs toro
Integer32
.1.3.6.1.4.1.5205.2.111.1.6.1.3
prvtCESCICModeThe mode of the clock input controller. Not all clock input controllers support all modes. The clock input controller status is 'locked' only if the clock input controller is in 'normal' mode.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.6.1.4
prvtCESCICTdmPortIf the clock input controller recovers a clock from a port , this variable indicates the TDM Port. Otherwise, it must be set to zero.rw
Integer32
.1.3.6.1.4.1.5205.2.111.1.6.1.5
prvtCESCICCircuitIf the clock input controller recovers a clock from a circuit, this variable indicates the circuit ID. Otherwise, it must be set to zero.rw
Integer32
.1.3.6.1.4.1.5205.2.111.1.6.1.6
prvtCESCICStatusThe status of the input reference.Reference is ok when the status is 'locked'. Otherwise, the status is 'notLocked'. Alternatively, if an error was detected at the input, the status indicates this error.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.6.1.7
prvtCESCICStateThe state is set to 'active' if the input controller was selected by the clock to drive the clock output. At least one input out of the clock-input-controllers attached to a clock must be in an 'active' state at any given timero
Enumeration
.1.3.6.1.4.1.5205.2.111.1.6.1.8
prvtCESCICMappTableThis table contains clock configuration and status monitoring information.
SEQUENCE OF PrvtCESCICMappEntry
.1.3.6.1.4.1.5205.2.111.1.7
prvtCESCICMappEntryprvtCESCICMappEntry
PrvtCESCICMappEntry
.1.3.6.1.4.1.5205.2.111.1.7.1
prvtCESCICMappModuleIdSlot of CES module installed.ro
Integer32
.1.3.6.1.4.1.5205.2.111.1.7.1.1
prvtCESCICMappClockNumberIndex for the conceptual row identifying a clock within this mapping tablero
Gauge32
.1.3.6.1.4.1.5205.2.111.1.7.1.2
prvtCESCICMappCICNumberIndex for the conceptual row identifying a clock input within this mapping tablero
Gauge32
.1.3.6.1.4.1.5205.2.111.1.7.1.3
prvtCESCICMappStateThe state is set to 'active' if the input controller was selected by the clock to drive the clock output. At least one input out of the clock-input-controllers attached to a clock must be in an 'active' state at any given time This value of this variable is equal to the prvtCESCICState variable in the CIC tablero
Enumeration
.1.3.6.1.4.1.5205.2.111.1.7.1.4
prvtCESApsTableThis table contains objects needed APS configuration
SEQUENCE OF PrvtCESApsEntry
.1.3.6.1.4.1.5205.2.111.1.8
prvtCESApsEntryprvtCESApsEntry
PrvtCESApsEntry
.1.3.6.1.4.1.5205.2.111.1.8.1
prvtCESApsModuleIdAn integer uniquely identifying slot of the CES module installed
Integer32
.1.3.6.1.4.1.5205.2.111.1.8.1.1
prvtCESApsEnableEnable/Disable Automatic Protection Switchingrw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.8.1.2
prvtCESApsActiveLineAPS active linerw
Integer32
.1.3.6.1.4.1.5205.2.111.1.8.1.3
prvtSdBerThresholdThe Signal Degrade Bit Error Rate. The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER). For example, a value of 5 indicates a BER threshold of 10^-5.rw
Integer32
.1.3.6.1.4.1.5205.2.111.1.8.1.4
prvtSfBerThresholdThe Signal Failure Bit Error Rate. The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER). For example, a value of 5 indicates a BER threshold of 10^-5.rw
Integer32
.1.3.6.1.4.1.5205.2.111.1.8.1.5
prvtCESUpdateFirmwareTableThis table contains object needed in update firmware of CES module
SEQUENCE OF PrvtCESUpdateFirmwareEntry
.1.3.6.1.4.1.5205.2.111.1.9
prvtCESUpdateFirmwareEntryprvtCESUpdateFirmwareEntry
PrvtCESUpdateFirmwareEntry
.1.3.6.1.4.1.5205.2.111.1.9.1
prvtCESModuleIdAn integer uniquely identifying slot of the CES module installed
Integer32
.1.3.6.1.4.1.5205.2.111.1.9.1.1
prvtCESFirmwareImageNameName of the firmware image filerw
OCTET STRING
.1.3.6.1.4.1.5205.2.111.1.9.1.2
prvtCESUpdateActionUpdate CES firmwarerw
Enumeration
.1.3.6.1.4.1.5205.2.111.1.9.1.3
prvtCESUpdateStatusThe status of the last update procedure, if any. This object will have a value of updateStatusUnknown(2) if no update process has been performed.ro
Enumeration
.1.3.6.1.4.1.5205.2.111.1.9.1.4
prvtCESTFTPServerIP Address of Tftp Serverrw
IpAddress
.1.3.6.1.4.1.5205.2.111.1.9.1.5
prvtCESConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.5205.2.111.2
prvtCESDsx1Compliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.5205.2.111.2.1
prvtCESDsx1Groups
OBJECT IDENTIFIER
.1.3.6.1.4.1.5205.2.111.2.2
PRVT-CES-MIB - SNMP MIB Reference | MIBs Explorer